• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 363
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 15
  • 9
  • 6
  • 6
  • 6
  • 1
  • 1
  • Tagged with
  • 388
  • 314
  • 99
  • 90
  • 56
  • 46
  • 41
  • 40
  • 39
  • 37
  • 35
  • 35
  • 34
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação da biocompatibilidade de dois adesivos dentinários pelo estudo das reações teciduais em conjuntivo de ratos /

Gomes, Ana Paula Martins. January 1994 (has links)
Orientador: Jaime Freitas Ribeiro / Banca: Carlos Eduardo Aun / Banca: Maria Amélia Maxímo de Araújo / Resumo: A biocompatibilidade de dois adesivos dentinários (Scotchbond MultiPurpose- 3M e Optibond Multi-Use - Kerr) foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os respectivos adesivos e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos periodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram moderado a discreto infiltrado inflamatório nos períodos iniciais de observação (14 e 30 dias) e reparação da área nos períodos posteriores (60 e 84 dias), com formação de cápsula fibrosa envolvendo todos os implantes. Os resultados obtidos nos permitiram concluir que: a) os dois adesivos dentinários são biologicamente aceitáveis quando colocados em contato com o tecido conjuntivo subcutâneo de ratos; b) houve reação moderada do tecido conjuntivo subcutâneo de ratos aos dois adesivos dentinários no período de observação de 14 dias, a qual persistiu com o adesivo Optibond MultiUse-light cure- (Kerr) aos 30 dias; c) as reações teciduais provocadas pelos dois adesivos nos períodos de observação de 60 e 84 dias foram semelhantes e biologicamente aceitáveis / Abstract: The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue / Mestre
172

Caracterização das propriedades mecânicas de biomateriais metálicos /

Landuci, Michel Cinto. January 2016 (has links)
Orientador: César Renato Foschini / Banca: Luiz Eduardo de Angelo Sanchez / Banca: Carlos Alberto Fortulan / Resumo: A engenharia está presente em diversos segmentos tecnológicos, entre eles, a ciência dos biomateriais. Após a segunda guerra mundial, o desenvolvimento rápido de novos materiais e tecnologias levaram alguns cientistas e cirurgiões a visualizarem aplicações médicas para alguns materiais nobres que se apresentaram altamente eficazes em termos de resistência mecânica e principalmente pela característica inerte apresentada. Para os biomateriais, muitos parâmetros devem ser analisados para assegurar a eficiência do material a ser utilizado, tendo em vista que este estará em contato íntimo com um organismo vivo e esta interação não pode ser prejudicial, tanto para o organismo quanto para o material, o qual se encontrará, muitas vezes, em um ambiente altamente agressivo. Este trabalho teve o objetivo de avaliar experimentalmente algumas propriedades mecânicas analisando representantes das principais classes de metais utilizados em aplicações médicas. Ainda, discorre sobre parâmetros biológicos, químicos e físicos através de estudos realizados por cientistas ao redor do mundo. Os metais analisados experimentalmente foram: titânio comercialmente puro, uma liga de titânio, aços inoxidáveis martensíticos e uma liga a base de cobalto. Tais materiais foram submetidos a ensaios de tração e dureza para análise das propriedades mecânicas correlacionadas. A elevada resistência mecânica da liga a base de cobalto e da liga de titânio puderam ser observadas quando comparadas com os demais materi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Engineering is present in several technology segments, among them, the science of biomaterials. After World War II, the fast development of new materials and technologies has led some scientistics and surgeons to visualize medical applications for some noble materials which appeared highly effective in terms of mechanical strength and especially by inert characteristic presented. For biomaterials, many parameters must be analyzed to ensure the efficiency of the material to be used, given that this will be in close contact with a living organism and this interaction may not be harmful, both for the body and for the material, which will often meet in a highly agressive environment. This work aimed to experimentally evaluate some mechanical properties analyzing representatives of major classes of metals used in medical applications. Besides, it talks about biological, chemical and physical parameters through studies conducted by scientistics around the world. The metals analyzed experimentally were: commercially pure titanium, a titanium alloy, martensitic stainless steel and a cobalt-based alloy. Such materials were subjected to tensile and hardness testing for analysis of correlated mechanical properties. This high strength of cobalt-based alloy and the titanium alloy could be observed when compared to other materials, being up to 73% higher compared to stainless steel and commercially pure titanium. On the other hand, the ductility of the coballt-based alloy is 68% higher when comapred to titanium alloy, being very similar compared to stainless steel and commercially pure titanium. The cobalt-based alloy also showed superior in terms of hardness, being 60% higher than in the titanium alloy, up to 11,7% higher than stainless steel and up to 181% higher than the commercially pure titanium, resulting in an indicative of a higher wear resistance of this alloy when compared to other materials analyzed / Mestre
173

Desenvolvimento de compósitos PEUAPM / apatitas para substituição e regeração óssea /

Souza, Diego Clemente de. January 2012 (has links)
Orientador: Antonio Carlos Guastaldi / Banca: José Augusto Marcondes Agnelli / Banca: Margarida Júri Saeki / Resumo: As propriedades do polietileno de ultra alto peso molecular (PEUAPM), tais como módulo de elasticidade semelhante ao osso e baixo coeficiente de fricção, tornam este polímero muito utilizado como biomaterial para a substituição óssea, contudo, por se tratar de um material bioinerte, sua fixação ao tecido ósseo somente é possível pela utilização de componentes metálicos e cimentos ósseos à base de polimetilmetacrilato (PMMA), os quais são relacionados a efeitos biológicos severos. As biocerâmicas de fosfatos de cálcio, denominadas apatitas, são materiais que apresentam bioatividade satisfatória, ligando-se quimicamente aos tecidos vivos e dependendo de suas fases, apresentam propriedades biológicas diferenciadas, pois suas velocidades de degradação não são iguais. O compósito obtido pela combinação satisfatória do PEUAPM com diferentes fases de apatitas deve proporcionar a obtenção de um biomaterial adequado para a regeneração e reposição do tecido ósseo com atividades biológicas diferenciadas. Neste trabalho, compósitos de PEUAPM com diferentes fases de apatita de importância biológica foram desenvolvidos com o objetivo de obter um biomaterial adequado para a reposição e regeneração óssea com a combinação das propriedades mecânicas do polímero com a bioatividade satisfatória das apatitas. Foram obtidas as seguintes fases de apatitas: fosfato de cálcio amorfo (ACP), hidroxiapatita (HA), fosfato tricálcico (TCP) e fosfato octacálcico (OCP) por via úmida. A caracterização das biocerâmicas de fosfatos de cálcio foi realizada utilizando-se as técnicas de Microscopia Eletrônica de Varredura - MEV, Difratometria de Raios X - DRX e Espectroscopia no Infravermelho - IV. Biocompósitos de PEUAPM com 20, 30 e 40 % em massa das diferentes fases de apatita (ACP, HA / -TCP e OCP) foram obtidos pela... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The properties of Ultra High Molecular Weight Polyethylene (UHMWPE), as modulus of elasticity similar to bone and low coefficient of friction, make this polymer widely used as biomaterial for bone replacement, however, because it is a bio-inert material, its attachment to bone tissue is only possible by the use of metal components and bone cements based on polymethylmethacrylate, which are related to severe biological effects. The bio-ceramics of calcium phosphate, called apatite, are materials that have satisfactory bioactivity by binding chemically to living tissue and depending on their stages have different biological properties, because their speed of degradation are not equal. The association of UHMWPE with different stages of apatite provide to obtain a suitable biomaterial for the regeneration and replacement of bone tissue with different biological activities. In this study, composites of Ultra High Molecular Weight Polyethylene (UHMWPE) with different apatite phases of biological importance were developed, aiming to obtain a suitable biomaterial for bone replacement and regeneration, with the combination of mechanical properties of the polymer with satisfactory bioactivity of apatite. Were obtained the following apatite phases: amorphous calcium phosphate (ACP), hydroxyapatite (HA), tricalcium phosphate (TCP) and octacalcium phosphate (OCP) by a wet process. The characterization of the bio-ceramics of calcium phosphate was performed using the techniques of Scanning Electron Microscopy - SEM, X-Ray Diffractometry - XRD and Infrared Spectroscopy - FTIR. Biocomposites of UHMWPE with 20, 30 and 40% by weight of the different phases of apatite (ACP, HA / -TCP and OCP) were obtained by direct mixing of powders in a mortar, followed by the milling process. The method chosen to obtain the biocomposites... (Complete abstract click electronic access below) / Mestre
174

Avaliação da influência do ABM/P-15 "flow" na cicatrização de defeitos de fenestração periodontal em ratos : estudo histológico e histométrico /

Sbrana, Michyele Cristhiane. January 2009 (has links)
Orientador: Maria José Hitomi Nagata / Banca: Álvaro Francisco Bosco / Banca: Ana Lúcia Pompéia Fraga de Almeida / Banca: Wilson Roberto Poi / Resumo: O propósito deste estudo foi avaliar, histologicamente e histometricamente, a cicatrização de defeitos de fenestração periodontal criados cirurgicamente em ratos e tratados com ABM/P-15 "flow". Defeitos de fenestração periodontal (4 x 3 x 1 mm) foram realizados na mandíbula de 60 ratos, divididos em dois grupos: C (Controle) - defeito preenchido apenas com coágulo sangüíneo; T (tratado) - defeito preenchido com ABM/P-15 "flow". Cada grupo foi dividido em 3 subgrupos (n=10), para eutanásia aos 10, 30 e 60 dias pós-operatórios. Medidas lineares e de área da cicatrização periodontal foram avaliadas e calculadas como uma porcentagem do defeito original. Os dados foram submetidos à análise estatística (Análise de variância, Tukey, p < 0,05). Os grupos C e T, em todos os períodos analisados, apresentaram quantidade de novo osso e densidade óssea similares. No Grupo C, não foi observada formação de cemento nos espécimes de 10, 30 e 60 dias, enquanto no Grupo T, novo cemento foi somente observado na maioria dos espécimes de 60 dias. Dentro dos limites deste estudo, pode-se concluir que o ABM/P-15 "flow" propiciou formação de cemento em defeitos de fenestração periodontal em ratos aos 60 dias pós-operatórios. A formação de novo tecido ósseo foi similar nos defeitos tratados com ABM/P-15 "flow" e nos defeitos controle. / Abstract: This study histologically analyzed the healing of periodontal fenestration defects surgically created in rats and treated with ABM/P-15 "flow". A periodontal fenestration defect (4 x 3 x 1 mm) was made on the right side of the mandible of 60 rats. They were divided into 2 groups: C (control) - defect filled with blood clot only; and T - defect filled with ABM/P-15 "flow". These groups were divided into subgroups and euthanized at 10, 30 or 60 days postoperative. Linear and area measurements of periodontal healing were evaluated and calculated as a percentage of the original defect. Data were statistically analyzed (analysis of variance, Tukey, p < 0.05). In all periods of evaluation, Groups C and T presented similar amounts of bone formation and bone density. New cementum formation was not observed in any specimen of Group C at 10, 30 and 60 days post-operative. In Group T, new cementum was observed in most 60-days specimens only. Within the limits of this study, it can be concluded that ABM/P-15 "flow" promoted cementum formation in periodontal fenestration defects in rats at 60 days post-operative. Similar bone formation was observed in the defects treated with ABM/P-15 "flow" and in the control defects. / Mestre
175

Avaliação comparativa do processo de incorporação de bloco sintético bifásico, e do osso autógeno : estudo histológico, histométrico e imunoistoquímico em coelhos /

Araújo, Júlio Maciel Santos de. January 2015 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Coorientadora: Daniela Ponzoni / Banca: Francisley Ávila Souza / Banca: Roberta Okamoto / Banca: Anibal Henrique Barbosa Luna / Banca: Fabiano Gonzaga Rodrigues / Resumo: Proposição: O objetivo desse trabalho foi avaliar a interface enxerto/leito receptor de um bloco sintético bifásico, composto de 60% de hidroxiapatita e 40% de beta tricálcio fosfato (β-TCP) por meio de análise histológica, histométrica e imunoistoquímica. Materiais e métodos: Foram utilizados 12 coelhos albinus que foram submetidos à cirurgia de enxerto ósseo aposicional em bloco para ganho em espessura. O enxerto autógeno foi removido da tíbia com o auxílio de uma broca trefina de 8 mm e parafusado na mandíbula esquerda, enquanto o bloco teste bifásico, composto de 60% de HA e 40% de β-TCP, foi parafusado na mandíbula direita. Os animais sofreram eutanásia após 2 e 8 semanas do procedimento cirúrgico e a peça foi removida para processamento e análises. Os resultados obtidos tiveram sua normalidade testada para definir o teste estatístico indicado. Resultados: Na análise histométrica, podemos observar que o grupo autógeno demonstrou maiores taxas de neoformação óssea nos dois tempos estudados quando comparados ao grupo do biomaterial, demonstrando uma diferença estatisticamente significativa. Quando comparamos os tempos estudados em cada material, o grupo autógeno teve um aumento considerável da segunda para a oitava semana, porem não foi encontrada diferenças estatisticamente significativas. O grupo biomaterial não teve um aumento significativa de neoformação óssea durante o período de reparo. Na imunoistoquímica, com relação ao tempo, podemos observar que a enzima TRAP mostrou maior manifestação no período de 2 semanas do que no período de 8 semanas considerando os dois materiais estudados. No quesito material, a proteína OC mostrou mais evidente no grupo autógeno de uma forma geral. Quando se avaliou material e tempo em cada proteína isoladamente não foram encontradas diferenças... / Abstract: Proposition: The purpose of this study was to evaluate the interface graft / recipient bed of a two-phase synthetic block, consisting of 60 % hydroxyapatite and 40 % beta tricalcium phosphate (β -TCP) by histological analysis, histometric and immunohistochemistry. Methods: We used 12 albinus rabbits that underwent appositional bone graft surgery block to gain in thickness. The autogenous graft was removed from the tibia with the aid of a trephine drill 8 mm and screwed into the left jaw, while the biphasic pattern block, composed of 60 % HA and 40% β -TCP, was screwed in the right jaw. The animals were euthanized after 2 and 8 weeks of surgery and the piece was removed for processing and analysis. The results were tested for normality define the statistical test indicated. Results: In histometric analysis, we can see that the autogenous group showed higher rates of bone formation in both times studied compared to the biomaterial group, demonstrating a statistically significant difference. When we compare the times studied in each material, the autogenous group had a significant increase from the second to the eighth week, however, there was no statistically significant differences. The biomaterial group remained during the repair period. In immunohistochemistry, with respect to time, we can see that the TRAP enzyme showed greater expression in the two weeks period than 8 weeks considering the two materials studied. In the item material, OC protein was more evident in the group of autogenic general. When assessing the material and time each protein alone were no statistically significant differences. Conclusion: The block kept tested values of bone formation below the control block, showing less potential for integration. Its composition has proven reliable for alveolar reconstruction in thickness to fill order. Further studies with... / Doutor
176

Desenvolvimento e caracterização de ligas de Co-Cr-Mo /

Martinelli, Carolina da Silva Machado. January 2016 (has links)
Orientador: Estevão Tomomitsu Kimpara / Co-orientador: Ana Paula Rosifini Alves Claro / Banca: Rubens Nisie Tango / Banca: Marina Amaral / Banca: Luís Augusto Sousa Marque da Rocha / Banca: André da Silva Antunes / Resumo: As ligas de Co-Cr têm o uso consagrado para reabilitação oral com próteses dentárias. Os procedimentos reabilitadores orais por implantes osseointegrados destacaram novas necessidades biomecânicas e estruturais das ligas metálicas. O objetivo deste estudo foi desenvolver e caracterizar três ligas metálicas de CoCr-Mo experimentais, para aplicação odontológica. Foram confeccionadas ligas de Co-Cr-Mo, com percentuais crescentes de Mo (6, 7 e 8% - A, B e C, respectivamente), por duas técnicas de processamento: L2, fusão para acréscimo de Mo a uma liga comercial certificada (American Society for Testing and Materials, 1996) (L1); e L3, fusão dos metais Co, Cr e Mo, comercialmente puros. As ligas em estudo foram caracterizadas microestruturalmente por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios X (DRX), fluorescência de raios X (XDR); fisicamente por microdureza, resistência à corrosão. Fibroblastos dérmicos humanos foram utilizados para avaliar a citotoxicidade das ligas experimentais após 1, 4 e 7 dias de cultura celular. Organização citoesquelética, adesão, viabilidade, morfologia e diferenciação celular foram avaliados por microscopia de fluorescência, análise bioquímica e MEV. Os resultados obtidos permitiram concluir que as ligas experimentais (L2A, L2B, L2C, L3A, L3B e L3C) apresentaram desempenho microsestrutural, mecânico e citotóxico superior à L1, sendo indicada para utilização biomédica e odontológica / Abstract: In Dentistry, the Co-Cr alloys are general used for oral rehabilitation by dental prosthesis. The oral rehabilitation procedures by osseointegrated implants point out to new metal alloys' biomechanical and structural necessities. The aim of this study was develop and characterize three experimental Co-Cr-Mo alloys, for dental application. Three alloys will be made out with different Mo's percentages by two processing techniques: L2, casting by addition of Mo to a certified commercial Co-Cr alloy (American Society for Testing and Materials, 1996) (L1); and L3, casting of purified commercial metals (Co, Cr, Mo). The experimental alloys were characterized by microstructure by digital optical microscopy, scanning electron microscopy, energy dispersive X-ray spectrometry, X-ray diffraction and X-ray fluorescence; and mechanically by microhardness and corrosion resistance. Human dermal fibroblasts were used to evaluate the biocompatibility of experimental Co-Cr alloys after 1, 4 and 7 days of culture. Cellular adhesion, proliferation, viability, cytoskeletal organization and morphology were investigated using fluorescence microscope, biochemical assay and SEM. Based on data was possible to concluded that experimental alloys (L2A, L2B, L2C, L3A, L3B e L3C) shown higher performance for microstructure, mechanical and cytotoxic as L1 and they are recommend to biomedical and dentistry applications / Doutor
177

Influência da deformação a frio na recristalização da liga Ti-30Ta para aplicações médicas /

Bortolini Junior, Celso. January 2016 (has links)
Orientadora: Ana Paula Rosifini Alves Claro / Coorientador: Ângelo Caporalli Filho / Banca: Marcos Valério Ribeiro / Banca: Maria Ismênia Sodero Toledo Faria / Resumo: Titânio e suas ligas são utilizados em implantes biomédicos devido a suas excelentes propriedades de volume, como resistência mecânica. Porém, tais propriedades estão diretamente ligadas à microestrutura, que por sua vez depende do processamento. O objetivo deste trabalho foi avaliar a microestrutura e a evolução da recristalização da liga Ti30Ta deformada a frio, após tratamento térmico. Os lingotes da liga Ti30Ta foram obtidos em um forno de fusão a arco voltaico. A liga foi tratada em um forno tubular sob vácuo a 950ºC por 24 horas para garantir a homogeneidade química e então foi forjada a frio em barras de 10 mm de diâmetro. As amostras foram solubilizadas a 900ºC por 2 horas e temperadas em água. Discos de 3 mm de espessura foram usados para análise. Para a avaliação da recristalização, foi realizado um tratamento térmico a 750ºC, 800ºC e 850ºC por 12 horas seguido de têmpera em água. A morfologia, composição e estrutura foram investigadas usando microscopia óptica, microscopia eletrônica de varredura, microscopia eletrônica de transmissão e difração de raios X. As análises de microscopia e difração de raios X indicaram a presença apenas da fase martensítica α' na amostra solubilizada e a presença das fases α' e α' nas amostras recristalizadas. Os ensaios mecânicos mostraram que houve uma melhoria nas propriedades mecânicas após a recristalização, sendo a temperatura de 750° que teve maior influência, porém houve também um incremento no módulo de elasticidade, o que é indesejado / Abstract: Titanium and its alloys have been used in biomedical devices due their excellent bulk properties, such as mechanical strength. However, these properties are very sensitive of microstructures which depend of the processing. The purpose of this study was to evaluate the microstructure and evolution of recrystallization of the could-swaged Ti30Ta alloy after heat treatment. Ingots of Ti30Ta alloy were obtained in arc melting furnace. Alloys were treated at 950° C for 24 hours for chemical homogenization in vacuum tubular furnace and cold worked by swaging into rods with 10 mm in diameter. Samples where then solution treated at 900° C for 2 hours and water quenched. Discs with 10 mm in diameter and 3 mm in thickness were used for analysis. For recrystallization evaluation, heat treatment was carried out at 750º C, 800º C and 850º C for 12 hours followed by water quenching. The morphology, composition and structure were investigated using optical microscopy, scanning electron microscopy, transmission electron microscopy and XRD (X-rays Diffraction Analysis). The microscopy and XRD analysis indicate the presence of the martensitic phase α' for the solution treated sample and the presence of both α' and α' phases for the recrystallized samples. Mechanical tests shows an increase in the mechanical strength to all the samples after recrystallization, with the temperature of 750° being the most impacting, however, it led an unwanted increase to the elastic modulus / Mestre
178

Avaliação da reação tecidual frente aos cimentos MTA Ângelus® cinza e um MTA fotopolimerizável experimental : análise microscópica em alvéolos dentários de ratos /

Costa, Mariana Machado Teixeira de Moraes. January 2008 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Robson Frederico Cunha / Banca: Ivaldo Gomes de Moraes / Banca: Fabíola Lemos Melhado / Banca: Roberta Okamoto / Resumo: Para contornar algumas dificuldades de manipulação do agregado de trióxido mineral (MTA) convencional, um MTA fotopolimerizável vem sendo desenvolvido. Desta forma, o objetivo do presente estudo foi avaliar a resposta tecidual frente ao uso deste material. Para isso, 57 tubos de polietileno preenchidos com o MTA experimental e o MTA cinza foram implantados em alvéolos de ratos. Como grupo controle, foram implantados tubos vazios. Os animais foram sacrificados após 30, 60 e 90 dias, sendo realizada a análise microscópica dos cortes obtidos e corados com Hematoxilina e Eosina. Foi possível concluir que o MTA fotopolimerizável apresentou uma resposta semelhante ao MTA cinza, caracterizada pela ausência de uma inflamação severa e pela deposição de tecido mineralizado em contato com o material. / Abstract: The aim of this study was to evaluate the tissue reaction to a Light Cured MTA or MTA Ângelus® gray. It was used 57 animals, which were divided in three groups. In the Control Group, empty tubes were inserted into the rat's sockets immediately after extraction. In the other groups, the tubes were filled with Light Cured MTA or MTA Ângelus®. After 30, 60 and 90 days after the implantation, the animals were sacrificed and the right hemi-maxilas were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6μm thickness and stained with HE. It was possible to conclude that Light Cured MTA presented a similar response when compared to MTA Ângelus®, being characterized by a mild inflammatory response and dystrophic calcifications areas. Despite of a favorable healing process obtained with this new experimental MTA, further studies should be conducted to elucidate these material properties and confirm the present results. / Doutor
179

Recobrimentos cerâmicos bioativos pelo processo sol-gel sobre Ti c.p. modificado por laser empregados em implantes /

Bini, Rafael Admar. January 2007 (has links)
Orientador: Antonio Carlos Guastaldi / Banca: Miguel Jafelicci Junior / Banca: Cecília Amélia de Carvalho Zavaglia / Resumo: A superfície do Ti c.p. foi modificada por feixe de Laser Nd:YAG e recoberta com compostos bioativos pelo método sol-gel, visando aplicações clínicas. As amostras de Ti c.p. foram irradiadas por Laser Nd:YAG pulsado em ar e pressão atmosférica, estabelecendo quatro condições de estudo. Os recobrimentos sobre as superfícies irradiadas foram realizados pelo método sol- gel, em que o sol foi preparado a partir dos precursores Ca(NO3)2.4H2O e H3PO4. Os filmes foram depositados por dip-coating e tratados termicamente por dois procedimentos (P1 e P2) com rampas de aquecimento diferentes, sendo que a temperatura final de sinterização foi de 700° C. As caracterizações das amostras foram realizadas pelas técnicas de análise térmica, microscopia eletrônica de varredura, difração de raios-X e espectroscopia no infravermelho com transformada de Fourier. Resultados da modificação por feixe de Laser mostraram que as quatro condições estabelecidas tiveram energia suficiente para promover a ablação na superfície irradiada. Verificou-se que não houve presença de nenhuma fase referente a nitretos de titânio e que é possível obter-se TiO, Ti3O e Ti6O com diferentes porcentagens, dependendo da fluência utilizada. Também se verificou que a modificação por Laser é um processo limpo e reprodutível, não deixando vestígios de contaminação. Pelos resultados dos recobrimentos bioativos, pode-se verificar a influência do tratamento térmico. As análises mostraram para o procedimento térmico 1 a formação de uma mistura de fases, CPP e ß-TCP, enquanto no procedimento 2 obteve-se HA e ß-TCP. Em todos os recobrimentos, utilizando-se o procedimento térmico 2, conseguiu-se transformar a superfície bioinerte do titânio para uma bioativa constituída de cerâmicas de fosfato de cálcio de interesse biológico. Portanto, esse...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The c.p. Ti surface was modified by Laser Nd:YAG and compounds bioactives coating by sol-gel method, seeking clinical applications. The samples of c.p. Ti were irradiated byLaser Nd:YAG pulsed in air and atmospheric pressure, establishing four study conditions. The coatings, on the irradiated surfaces, were carried through by the sol- gel method, where the sol was prepared starting from the precursors Ca(NO3)2.4H2O and H3PO4. The coatings were deposited by dip-coating and treated termically by two procedures with heating ramps different (P1 and P2), and final temperature was 700° C. The characterizations of the samples were carried through by SEM, XRD and FT-IR. Results of the modification by laser beam showed that the four established conditions suggested have enough energy to promote the ablation in the irradiated surface. It was verified that there was not presence of any phase regarding nitretes of titanium and that it is possible to obtain TiO, Ti3O and Ti6O with different percentages, depending on the fluency used. Also, it is verified that the modification for Laser is a clean process, not leaving tracks of contamination, important characteristic for clinical applications. For the results of the bioactives coatings , the influence of thermal treatment can be verified. The analysis showed in the procedure 1 the formation of a mixture of phases, CPP and ß-TCP, while in the procedure 2, it was obtained HA and ß-TCP. In all coating, using the thermal procedure 2, it was gotten to transform the bioinert surface of the titanium for a bioactive constituted of ceramic of calcium phosphate of biological interest. Therefore, that procedure presented satisfactory for the obtaining of bioactives coatings of calcium phosphate for be used in dental and orthopedical implants. / Mestre
180

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS) /

Gregolin, Rafael Ferreira. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Banca: João Antonio Pereira / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços - engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Abstract: Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it's used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS® / Mestre

Page generated in 0.0796 seconds