• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • 1
  • Tagged with
  • 10
  • 10
  • 6
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The in vivo antibacterial efficacy of ultrasound after hand and rotary instrumentation in human mandibular molars /

Carver, Keith Charles, January 2005 (has links)
Thesis (M.S.)--Ohio State University, 2005. / Includes bibliographical references (leaves 280-305). Available online via OhioLINK's ETD Center.
2

A three-dimensional photoelastic stress analysis of the mandibular staple bone plate a thesis submitted in partial fulfillment ... denture prosthodontics ... /

Riedy, Stephen J. January 1984 (has links)
Thesis (M.S.)--University of Michigan, 1984.
3

Biocompatability of the Bosker Transmandibular Implant : components of the system in a short-term animal trial /

Arvier, J. F. January 1987 (has links) (PDF)
Thesis (M.D.S.)--University of Adelaide, 1987. / Typescript. Includes bibliographical references (leaves 131-167).
4

A Comparison Study of Temporomandibular Joint Symptoms in Patients Following Mandibular Advancement by Bilateral Sagittal Split Osteotomies: Rigid Fixation Versus Nonrigid Fixation

Flynn, Brent Cameron January 1989 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Primary consideration must be given to the temporomandibular joint when planning and performing orthognathic surgical procedures. It has long been understood that the status of the temporomandibular joint can easily and unintentionally be altered during orthognathic surgery, regardless of the method of fixation used. With the advent of modern fixation techniques, many clinicians and investigators have questioned the effects of rigid fixation on the temporomandibular joint. To investigate this, a clinical study of 40 patients treated with mandibular advancement for retrognathism was performed. Twenty patients were treated with rigid fixation while another 20 patients had inferior border wires placed with anterior skeletal fixation. All patients were asked questions regarding the history of their temporomandibular joints. In addition, all patients received a clinical postoperative temporomandibular joints. In addition, all patients received a clinical postoperative temporomandibular joint evaluation. The results were statistically analyzed with the Chi-square analysis and Standard T test. It was determined that the Null Hypothesis could not be rejected for any of the symptoms evaluated in this study. The results support the belief that rigid fixation is no different when compared to wire osteosynthesis in terms of prevalence of temporomandibular joint symptoms.
5

Biocompatability of the Bosker Transmandibular Implant : components of the system in a short-term animal trial

Arvier, J. F. (John Frederick) January 1987 (has links) (PDF)
Typescript. Bibliography: leaves 131-167.
6

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS)

Gregolin, Rafael Ferreira [UNESP] 20 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-20Bitstream added on 2014-06-13T20:35:19Z : No. of bitstreams: 1 gregolin_rf_me_ilha.pdf: 3746269 bytes, checksum: b2a1686375b3a28a8709c13b5b75a4bd (MD5) / A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços – engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it’s used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS®
7

Análise da distribuição das tensões em próteses protocolo mandibulares com estruturas fresadas por CAD/CAM e confeccionadas pela técnica convencional: análise pela fotoelasticidade e extensometria / Analysis of stress distribution in full-arch fixed mandibular prosthesis with structures made with the CAD/CAM technology and with the conventional technique: evaluation through photoelastic and strain gauge analysis

Medeiros, Rodrigo Antonio de [UNESP] 12 December 2016 (has links)
Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-17T18:59:53Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.docx: 4055404 bytes, checksum: 8420d48d6379115c0945c7b9f391bbc6 (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Incluir o número do processo de financiamento nos agradecimentos da dissertação/tese. A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, estas informações e realize uma nova submissão. Agradecemos a compreensão. on 2017-01-20T15:26:30Z (GMT) / Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-20T21:34:08Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-23T19:00:09Z (GMT) No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Made available in DSpace on 2017-01-23T19:00:09Z (GMT). No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) Previous issue date: 2016-12-12 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse estudo foi avaliar a distribuição de tensão, por meio dos métodos fotoelástico e extensometria, em próteses protocolo mandibulares (tipo Branemärk) com infraestruturas confeccionadas com diferentes materiais e técnicas, sob força de compressão. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula que recebeu cinco implantes 4x11 mm hexágono externo entre os forames mentonianos. Os grupos foram divididos em: Grupo I - infraestrutura fundida em níquel-cromo com revestimento oclusal em resina acrílica (n=7); Grupo II - infraestrutura fundida em níquel-cromo com revestimento oclusal em cerâmica (n=7); Grupo III - infraestrutura fresada em Zircônia estabilizada por óxido de ítrio com revestimento em cerâmica (n=7). Inicialmente, foi realizado o teste da fotoelasticidade e, posteriormente, a extensometria. Pela metodologia da fotoelasticidade, com auxílio de uma máquina de ensaio universal (EMIC) foram aplicadas cargas axiais de 70 N na região do implante mais anterior, entre os incisivos, e no centro do primeiro molar de cada lado. Por meio de imagens fotográficas e com o auxílio do programa Adobe Photoshop CS6, as imagens foram analisadas de acordo com o número de franjas de alta intensidade nos grupos testados. Para a metodologia da extensometria, as cargas foram aplicadas da mesma maneira da metodologia da fotoelasticidade e a medição das tensões foi realizada em duas regiões distintas. Para a primeira região, dois extensômetros elétricos de resistência foram posicionados horizontalmente na região mesial e distal dos cinco implantes, diretamente sobre a crista marginal do modelo fotoelástico. Para a segunda região, a resina fotoelástica foi removida da superfície vestibular e lingual de cada implante, sendo mantida1 mm de resina intacta, onde os extensômetros foram fixados verticalmente. Foram realizados os mesmos testes de compressão descritos anteriormente. Os valores de tensão registrados foram agrupados em tabelas e submetidas à análise de variância (ANOVA) dois fatores e ao teste de Tukey com significância de 5%. Os resultados das duas metodologias demonstraram menores valores de tensão para o Grupo I, quando comparado aos demais grupos. É possível concluir que as próteses protocolo com infraestrutura fundida em metal e revestimento oclusal acrílico demonstraram melhores resultados biomecânicos. / This study aimed to evaluate the stress distribution in full-arch fixed mandibular prosthesis (Branemärk type) with infrastructure made of different materials and techniques, and under compressive force, through photoelastic and strain gauge analysis. A photoelastic cast of an edentulous jaw was fabricated and received five external hexagon implants (4x11mm) between the mental foramen. The groups were divided into: Group I - Nickel-Chrome fused infrastructure with acrylic resin occlusal coating; Group II - Nickel-Chrome fused infrastructure with ceramic occlusal coating; Group III - Yttria-stabilized zirconia fused infrastructure with ceramic coating. First, the photoelastic analysis was performed and later the strain gauge analysis. A force of 70 N was applied by using a testing machine (EMIC) in the region of the most anterior implant, between incisors, and in the center of the first molar on each side. The images were analyzed by a blinded evaluator through images and by using Adobe Photoshop CS6, according to the number of high intensity fringes in each group. Regarding the strain gauge analysis, the stress measure was performed in two distinct regions. For the first region, two resistance strain gauges were placed horizontally in the mesial and distal regions of the five implants, directly on the marginal ridge of the photoelastic cast. For the second region, the photoelastic resin was removed on the buccal and lingual surfaces of each implant, leaving 1 mm of intact resin, where the strain gauges were placed vertically. The same compression tests described above were carried out. Data were submitted to two-way ANOVA and to the Tukey post-hoc test with 5% level of significance. The results of both methods showed lower stress values for Group I, when compared to other groups. It can be concluded that when rigid materials are used for infrastructure fabrication, the esthetic coating influences the load generated on the marginal bone around the implant. The ceramic coating showed less satisfactory results. / FAPESP: 2014/14088-0 / FAPESP: 2014/11605-3
8

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS) /

Gregolin, Rafael Ferreira. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Banca: João Antonio Pereira / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços - engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Abstract: Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it's used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS® / Mestre
9

Desenvolvimento de dois modelos de mini-implantes e componentes protéticos: correlação da macroestrutura e propriedades mecânicas / Development of two models of mini-implants and prosthetic components: macrostructure correlation and mechanical properties

Valente, Mariana Lima da Costa 19 January 2018 (has links)
O edentulismo acomete grande parcela da população mundial, especialmente os idosos, gerando perda da função mastigatória, desordens nutricionais, estética desfavorável e redução da qualidade de vida. Como alternativa a esses problemas, as overdentures implanto retidas tem representado uma modalidade de tratamento eficiente para reabilitação da mandíbula. Assim, o presente estudo teve por objetivo desenvolver e avaliar a efetividade de dois modelos de mini-implantes dentários e um componente protético, cápsula de retenção para overdentures mini-implante retidas. Para tal, um total de 30 mini-implantes (n=10) foram utilizados: modelo comercial Intra-Lock® System, experimental rosqueado e experimental helicoidal. Ambos os mini-implantes desenvolvidos no estudo foram confeccionados em titânio Grau IV, nas dimensões de Ø 2,0 mm x 10 mm de comprimento e submetidos a tratamento de superfície nanométrico. O desempenho dos mesmos foi comparado ao modelo comercial selecionado quanto à estabilidade primária, por meio de torque de inserção e ensaio de arrancamento e à distribuição de tensões, através dos métodos fotoelástico e de correlação de imagens digitais (CID). Foram realizados carregamentos puntiformes axiais e oblíquos (inclinação de 30º do modelo), com cargas de 100 N para a fotoelasticidade e de 250 N axial e 100 N oblíquo para a CID. Para análise do componente protético foi utilizado o teste de resistência à fadiga. 60 cápsulas (n=20): Poliacetal, Politetrafluoretileno (PTFE) e o-ring convencional (Intra-Lock®) foram capturadas aos pares, com resina acrílica e submetidas a 3625 ciclos de inserção/remoção, simulando 30 meses de uso da overdenture. A deformação interna e externa dos componentes foi avaliada por meio de Estereomicroscópio Óptico. Os dados obtidos foram submetidos a ANOVA e teste de Tukey (&alpha;=0,05). O torque de inserção (TI) e ensaio de arrancamento apresentaram significância estatística para todos os modelos (p<0,05), sendo o TI maior para o mini-implante rosqueado e a força máxima de arrancamento para o modelo Intra-Lock®. Quanto à análise de tensões por meio da fotoelasticidade verificou-se de maneira geral, maiores tensões no terço médio e apical dos mini-implantes. O mesmo padrão foi observado para a CID, porém, neste caso, com tensões significativamente maiores (p<0,05) para os mini-implantes rosqueados na condição de carregamento axial, para o oblíquo não foram encontradas diferenças significativas (p>0,05). Quanto à análise dos componentes protéticos, a cápsula de poliacetal apresentou a maior retenção (p<0,05), seguida do o-ring e PTFE. Menor deformação foi observada para o o-ring (p<0,05) e maior deformação interna (p<0,05), após a realização da fadiga, para o poliacetal. O mini-implante rosqueado apresentou de modo geral estabilidade primária e distribuição de tensões comparável ao modelo comercial avaliado. O componente protético de poliacetal demonstrou superioridade em relação ao o-ring da Intra-Lock® quanto à força de retenção e apesar da maior deformação interna sofrida, sugere-se sua substituição após no mínimo 30 meses de uso da overdenture / Edentulism affects a large part of the world population, especially the elderly, generating loss of masticatory function, nutritional disorders, unfavorable esthetics and reduction of quality of life. As an alternative to these problems, overdentures implant retained have represented an efficient treatment modality for mandibular rehabilitation. Thus, the present study aimed to develop and evaluate the effectiveness of two models of dental mini-implants and a prosthetic component, retention caps for overdentures mini-implant retained. To do this, a total of 30 mini-implants (n=10) were used: Intra-Lock® System commercial model, experimental threaded and experimental helical. Both mini-implants developed in the study were made in Titanium Grade IV, in the dimensions of Ø 2.0 mm x 10 mm in length and submitted to a nanometric surface treatment. Their performance were compared to the commercial model selected for primary stability by means of insertion torque and pullout test and stress distribution using photoelastic and digital image correlation (DIC) methods. Axial and oblique punctiform loads (30º inclination of the model) were performed, with loads of 100 N for photoelasticity and 250 N axial and 100 N oblique for DIC. For the analysis of the prosthetic component, the fatigue strength test was used. 60 capsules (n=20): Polyacetal, Polytetrafluoroethylene (PTFE) and conventional O-ring (Intra-Lock®) were captured in pairs with acrylic resin and subjected to 3625 insertion/removal cycles, simulating 30 months of overdenture use. The internal and external deformation of the components was evaluated using an Optical Stereomicroscope. Data were submitted to ANOVA and Tukey\'s test (&alpha;=0.05). The insertion torque (IT) and pullout test were statistically significant for all models (p<0.05), with IT being highest for the threaded mini-implant and maximum pulling force for the Intra-Lock® model. As for stress analysis by photoelasticity, it was generally observed that there were higher tensions in the middle and apical third of the mini-implants. The same pattern was observed for the DIC, but in this case, with significantly higher stresses (p<0.05) for the mini-implants threaded in the axial loading condition, no significant differences were found for the oblique (p>0.05). As for the analysis of prosthetic components, the polyacetal caps presented the highest retention (p<0.05), followed by o-ring and PTFE. Lower deformation was observed for o-ring (p<0.05) and greater internal deformation (p<0.05), after fatigue, for polyacetal. The threaded mini-implant generally showed primary stability and strain distribution comparable to the commercial model evaluated. The polyacetal prosthetic component showed superiority over the Intra-Lock® o-ring for the retention force and despite the greater internal deformation suffered, it is suggested to replace it after at least 30 months of overdenture use
10

Within-subject comparison of two- versus three-implant-assisted mandibular overdenture : patient-based outcomes

Alesawy, Aminah 02 1900 (has links)
No description available.

Page generated in 0.0982 seconds