• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • Tagged with
  • 61
  • 45
  • 14
  • 14
  • 10
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio

Pereira, Eduardo Ferreira 08 July 2015 (has links)
Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-03-03T12:48:10Z No. of bitstreams: 1 2015_EduardoFerreiraPereira.pdf: 3187364 bytes, checksum: 50b7a71b45f3b71d8af9c22fc9653768 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-26T17:53:27Z (GMT) No. of bitstreams: 1 2015_EduardoFerreiraPereira.pdf: 3187364 bytes, checksum: 50b7a71b45f3b71d8af9c22fc9653768 (MD5) / Made available in DSpace on 2016-05-26T17:53:27Z (GMT). No. of bitstreams: 1 2015_EduardoFerreiraPereira.pdf: 3187364 bytes, checksum: 50b7a71b45f3b71d8af9c22fc9653768 (MD5) / O Brometo de Etídio (BE) é um composto fluorescente que tem seu rendimento quântico muito aumentado quando intercalado à moléculas de DNA e RNA e, por isto, é usado para detecção destas espécies em procedimentos de eletroferese em gel. Devido a estas características, esta substância é considerada perigosa, pois pode causar danos ao material genético humano sendo classificado como um agente mutagênico /tóxico. Para realização do seu descarte é necessário um processo de inertização, sendo um dos mais aplicados o proposto por Lunn e Sansone em que são utilizados o ácido hipofosfórico e o nitríto de sódio para oxidação da substância. Porém, esta é uma reação de longa duração e a sua finalização deve ser atestada com o uso da detecção por fluorescência. Considerando este aspecto, o principal objetivo do trabalho foi construir e avaliar um sistema automatizado de baixo custo com detecção fluorimétrica, empregando-se um LED (máximo de emissão em 535 nm) para monitorar a degradação do BE. Este instrumento é controlado por microcontroladores (PIC 16F877A e PIC 16F628) que são responsáveis pelos controles dos processos de fluxo das amostras e do fluido carreador e por adquirir e processar o sinal do sistema de detecção, composto de dois fotodiodos e como filtros para, emissão do BE, foram utilizados plásticos de coloração alaranjada. O Fluorímetro proposto foi avaliado tanto em batelada quanto em um sistema de fluxo e apresentou limites de detecção de 0,33 mg L-1 no sistema de fluxo com abordagem stoped-flow e 0,04 mg L-1 em batelada (utilizando cubeta). As medidas realizadas com o instrumento foram comparadas ao de um fluorímetro comercial de bancada e em todas as comparações não foram observadas diferenças significativas ao nível de 95% de confiança. Foram realizados testes para verificar se o sistema de decisão do instrumento proposto era confiável para indicar automaticamente o final da degradação sendo observada uma taxa de 100% de acerto para as amostras testadas com concentrações acima do limite máximo permitido e abaixo deste limite (5 mg L-1). Alternativamente, avaliou-se a possibilidade de uso de um sistema de detecção de BE utilizando um LED como fonte de excitação e medidas das componentes RGB de imagens a partir de um aplicativo e da câmera de um aparelho celular. Para esta abordagem foi encontrado um limite de detecção de 0,91 mg L-1 utilizando apenas componente R. Comparando-se os resultados obtidos para amostras fortificadas com BE realizadas com o fluorímetro proposto e com a detecção via celular com os resultados obtidos com um espectrofluorímetro comercial, não foram observadas diferenças significativas ao nível de 95 % de confiança. O Fluorímetro de LED proposto se mostrou eficiente e teve um rendimento satisfatório a um baixo custo (cerca de US$ 200) podendo ser aplicado para a detecção de BE no procedimento de descarte ou na detecção destes em amostras residuais. ______________________________________________________________________________ ABSTRACT / Ethidium Bromide (BE) is a fluorescent compound which has a significant enhancement of quantum yield when intercalated with RNA and DNA molecules and, due to such effect, it is applied for detection of these species in gel electrophoresis. For that reason, BE is considered dangerous, producing damages to human genetic material and classified as a mutagenic/toxic agent. In order to discard BE residues, is necessary a prior process to turn the substance inert and one of the most applied protocols is the proposed by Lunn and Sansone, where hipofosforic acid and sodium nitrite are used to oxidize the BE. However, this reaction requires a long time period and its finalization must be attested by fluorescence measurements. Considering this, the main objective of this work was to fabricate and evaluate a low cost automated system with fluorometric detection, using a LED (maximum emission in 535 nm) to to monitor BE degradation. The proposed instrument is controlled by microcontrollers (PIC 16F877A and PIC 16F628) that controls the sample and carrier flows and performs the acquisition and processing of the analytical signal from the detector, comprising two photodiodes covered by two pieces of transparent orange plastic. The proposed fluorometer was tested with the use of batch or flow based strategies. Using a stopped-flow system, the limit of detection of 0.33 mg L-1 was achieved and for the batch determination the detection limit was 0.04 mg L-1. The determinations performed with the proposed LED fluorometer were compared to the determinations performed with a commercial spectrofluorometer with no significant differences at 95 % confidence level. Tests were also conducted to verify if the decision system of the proposed instrument was reliable to automatically indicate the end of degradation, being checked 100 % of accuracy for the tested samples with BE concentrations beyond and below the limit of concentration of 5 mg L-1. Alternatively, the detection of BE using a green LED as excitation source and measurements of RGB pattern from photographic images acquired by a cell phone was evaluated. For this approach, the detection limit of 0.91 mg L-1 was stimated using only the Red component of RGB. By comparing the results acquired with the proposed fluorometer/cell phone detection with the data obtained with a commercial spectrofluorometer for BE fortified samples, no significant differences were observed at the 95 % confidence level. The proposed LED Fluorometer was efficient and had a satisfactory performance at a low cost (US$ 200) and can be applied to the detection of BE in the disposal procedure or detecting in residual samples.
2

Ações eletrofisiológicas da piridostigmina em humanos

Liberman, Alexandre January 2003 (has links)
INTRODUÇÃO. O Brometo de piridostigmina tem demonstrado atividade cardíaca, ao aumentar a variabilidade da freqüência cardíaca e diminuir as extrassístoles ventriculares em pacientes com insuficiência cardíaca. Como droga de potencial efeito antiarrítmico, faz-se necessário testar suas modificações nas variáveis eletrofisiológicas, passo inicial no desenvolvimento e uso das drogas com efeito antiarritmico. OBJETIVO. Avaliar os efeitos eletrofisiológicos da piridostigmina em pacientes com indicação prévia para realizar o procedimento. MÉTODOS. Pacientes com indicação para estudo eletrofisiológico participaram de um estudo quase-experimento testando o uso da piridostigmina nas ações eletrofisiológicas. Os pacientes selecionados realizavam seus exames sem efeito da piridostigmina, sendo registradas as variáveis em estudo, intervalos de condução, ciclo básico, ponto de Wenckebach, períodos refratários atriais, do nó atrioventricular e ventriculares. O exame era repetido após uma hora e meia do uso da droga, 45 mg de dose única de piridostigmina, e novamente eram registradas as principais variáveis do estudo. RESULTADOS. A amostra compreendeu 15 pacientes, e as principais indicações foram síncope e palpitações. O ciclo básico obteve uma média sem o efeito da piridostigmina e após sua ação de 906± 143,32ms vs 914±152,03ms, p=0,58. A recuperação sinusal na medida de 600ms foi de 275,85± 110ms vs 248,57 ± 123,40ms, p=0,489. A média do intervalo de condução AH controle e piridostigmina foi 88,60±31ms vs 92,80±35ms, p= 0,872 .A média do período refratário atrial, controle e piridostigmina, no ciclo de 600ms foi 147,08±124 ms vs 122,83 ±120 ms, p=0,478. A média do período refratário do nó atrioventricular no ciclo de 600ms foi 327,69± 76ms vs 345,38±89ms p=0,06. Por fim, a comparação entre as médias do período refratário ventricular no ciclo de 400ms foi de 238,00±28ms vs 245,33± 33ms, p=0,028. CONCLUSÃO. A piridostigmina não alterou consistentemente significativamente as variáveis eletrofisiológicas na amostra de pacientes estudados.
3

Ações eletrofisiológicas da piridostigmina em humanos

Liberman, Alexandre January 2003 (has links)
INTRODUÇÃO. O Brometo de piridostigmina tem demonstrado atividade cardíaca, ao aumentar a variabilidade da freqüência cardíaca e diminuir as extrassístoles ventriculares em pacientes com insuficiência cardíaca. Como droga de potencial efeito antiarrítmico, faz-se necessário testar suas modificações nas variáveis eletrofisiológicas, passo inicial no desenvolvimento e uso das drogas com efeito antiarritmico. OBJETIVO. Avaliar os efeitos eletrofisiológicos da piridostigmina em pacientes com indicação prévia para realizar o procedimento. MÉTODOS. Pacientes com indicação para estudo eletrofisiológico participaram de um estudo quase-experimento testando o uso da piridostigmina nas ações eletrofisiológicas. Os pacientes selecionados realizavam seus exames sem efeito da piridostigmina, sendo registradas as variáveis em estudo, intervalos de condução, ciclo básico, ponto de Wenckebach, períodos refratários atriais, do nó atrioventricular e ventriculares. O exame era repetido após uma hora e meia do uso da droga, 45 mg de dose única de piridostigmina, e novamente eram registradas as principais variáveis do estudo. RESULTADOS. A amostra compreendeu 15 pacientes, e as principais indicações foram síncope e palpitações. O ciclo básico obteve uma média sem o efeito da piridostigmina e após sua ação de 906± 143,32ms vs 914±152,03ms, p=0,58. A recuperação sinusal na medida de 600ms foi de 275,85± 110ms vs 248,57 ± 123,40ms, p=0,489. A média do intervalo de condução AH controle e piridostigmina foi 88,60±31ms vs 92,80±35ms, p= 0,872 .A média do período refratário atrial, controle e piridostigmina, no ciclo de 600ms foi 147,08±124 ms vs 122,83 ±120 ms, p=0,478. A média do período refratário do nó atrioventricular no ciclo de 600ms foi 327,69± 76ms vs 345,38±89ms p=0,06. Por fim, a comparação entre as médias do período refratário ventricular no ciclo de 400ms foi de 238,00±28ms vs 245,33± 33ms, p=0,028. CONCLUSÃO. A piridostigmina não alterou consistentemente significativamente as variáveis eletrofisiológicas na amostra de pacientes estudados.
4

Ações eletrofisiológicas da piridostigmina em humanos

Liberman, Alexandre January 2003 (has links)
INTRODUÇÃO. O Brometo de piridostigmina tem demonstrado atividade cardíaca, ao aumentar a variabilidade da freqüência cardíaca e diminuir as extrassístoles ventriculares em pacientes com insuficiência cardíaca. Como droga de potencial efeito antiarrítmico, faz-se necessário testar suas modificações nas variáveis eletrofisiológicas, passo inicial no desenvolvimento e uso das drogas com efeito antiarritmico. OBJETIVO. Avaliar os efeitos eletrofisiológicos da piridostigmina em pacientes com indicação prévia para realizar o procedimento. MÉTODOS. Pacientes com indicação para estudo eletrofisiológico participaram de um estudo quase-experimento testando o uso da piridostigmina nas ações eletrofisiológicas. Os pacientes selecionados realizavam seus exames sem efeito da piridostigmina, sendo registradas as variáveis em estudo, intervalos de condução, ciclo básico, ponto de Wenckebach, períodos refratários atriais, do nó atrioventricular e ventriculares. O exame era repetido após uma hora e meia do uso da droga, 45 mg de dose única de piridostigmina, e novamente eram registradas as principais variáveis do estudo. RESULTADOS. A amostra compreendeu 15 pacientes, e as principais indicações foram síncope e palpitações. O ciclo básico obteve uma média sem o efeito da piridostigmina e após sua ação de 906± 143,32ms vs 914±152,03ms, p=0,58. A recuperação sinusal na medida de 600ms foi de 275,85± 110ms vs 248,57 ± 123,40ms, p=0,489. A média do intervalo de condução AH controle e piridostigmina foi 88,60±31ms vs 92,80±35ms, p= 0,872 .A média do período refratário atrial, controle e piridostigmina, no ciclo de 600ms foi 147,08±124 ms vs 122,83 ±120 ms, p=0,478. A média do período refratário do nó atrioventricular no ciclo de 600ms foi 327,69± 76ms vs 345,38±89ms p=0,06. Por fim, a comparação entre as médias do período refratário ventricular no ciclo de 400ms foi de 238,00±28ms vs 245,33± 33ms, p=0,028. CONCLUSÃO. A piridostigmina não alterou consistentemente significativamente as variáveis eletrofisiológicas na amostra de pacientes estudados.
5

Análise exergoeconômica de um chiller de absorção de 10tr integrado a um sistema de microgeração com microturbinaa gás de 30kw

VILLA, Alvaro Antonio Ochoa 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:34:40Z (GMT). No. of bitstreams: 2 arquivo1979_1.pdf: 4262749 bytes, checksum: 6592fa1ffeccb983a84926eb95aa4c5e (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho tem como finalidade o estudo numérico do funcionamento de um chiller de absorção (LiBr-água) de simples efeito em regime permanente, com capacidade de 10TR, acionado por água quente e tendo como fonte de calor os gases de exaustão de uma micro-turbina a gás natural de 30kW de potência, localizado no laboratório Cogencasa da Universidade Federal de Pernambuco. Foi desenvolvida uma metodologia computacional na plataforma EES-32 (Engineering Equation Solver), para avaliar a influência dos principais parâmetros de operação do sistema sobre a capacidade de resfriamento e o COP. A modelagem termodinâmica baseia-se nos princípios de conservação de energia, massa e das espécies, além das correlações de transmissão de calor, sendo conformado por uma serie de funções para a determinação das propriedades termodinâmicas (entalpia e entropia da mistura H2O-BrLi) e coeficientes dos trocadores de calor. A análise exergoeconômica é baseada nos sistemas de unidades produtivas, para avaliar a viabilidade técnica do sistema de cogeração. Para a análise exergética foi calculada a Exergia total dos fluidos de trabalho levando em consideração as parcelas físicas e químicas. O sistema de cogeração foi integrado ao modelo computacional com o propósito de estudar os custos exergéticos e monetários do sistema, verificando o balanço monetário da geração de energia elétrica pela microturbina e a produção de água gelada, mediante a recuperação dos gases da combustão para o acionamento do chiller de absorção. Analisam-se as irreversibilidades para a identificação dos pontos críticos nos componentes do sistema de cogeração. Da análise exergoeconomica, foram analisados os custos mínimos de produção de energia elétrica para produzir lucros para o empreendimento, além da determinação dos custos gerais monetários da produção de água gelada, fria e quente do chiller. Finalmente foram determinados os valores da eficiência energética e exergética global do sistema de cogeração
6

Degradação do brometo de etídio em solução aquosa via ozonização / Degradation of ethidium bromide in aqueous solution via ozonation

Rocha, Cyntia Cristina da 11 July 2014 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-05-05T14:06:11Z No. of bitstreams: 1 texto completo.pdf: 2977630 bytes, checksum: ddac172d74744a5a2de8d5b5899928fa (MD5) / Made available in DSpace on 2016-05-05T14:06:11Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2977630 bytes, checksum: ddac172d74744a5a2de8d5b5899928fa (MD5) Previous issue date: 2014-07-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O brometo de etídio é um composto comumente utilizado em laboratórios de biologia molecular como marcador para visualização de DNA. Apresenta riscos potenciais de toxicidade e mutagenicidade, sendo necessário o tratamento dos seus resíduos antes do descarte. Na tentativa de evitar riscos de contaminação ambiental, a ozonização tem se mostrado uma técnica promissora devido o seu elevado potencial oxidante. Embora o uso de ozônio para degradação de compostos orgânicos venha se tornando cada vez mais comum, ainda pouco se sabe sobre os intermediários de reação e produtos formados durante a ozonização de efluentes. Dessa forma, é preciso garantir que esses produtos de degradação não sejam tóxicos. Para tanto se faz necessária aplicação de estudos toxicológicos. Esse trabalho estudou a cinética de degradação do brometo de etídio e a eficiência de degradação do corante em solução aquosa na presença e ausência dos catalisadores ZnO, Al 2O3 e resina XAD- 7, além de identificar o caráter tóxico dos produtos de degradação. Na aplicação da ozonização, observou-se que a cinética de degradação do composto é favorecida em meio ácido, sendo dependente também da concentração de ozônio. A eficiência de degradação é dependente do pH do meio e apresenta melhores resultados em meio básico, com cerca de 96% de remoção do corante. Nessa técnica, os produtos de degradação, tanto para meio ácido, quanto para meio básico, apresentaram toxicidade. A ozonização catalítica apresentou aumento da eficiência de degradação do brometo de etídio na presença do catalisador ZnO em meio ácido, em uma dosagem de 0,5 g L-1, aumentando o percentual de degradação de 75,3% para 95,5%, nessa condição. O Al2O3 e a XAD-7 não apresentaram atividade catalítica significativa. Os testes de toxicidade realizados para os produtos de degradação via ozonização catalítica se apresentaram atóxicos quando comparados aos resultados da ozonização sem a presença de catalisadores. / Ethidium bromide is a compound commonly used in molecular biology laboratories as a marker for visualization of DNA. Presents potential risks of toxicity and mutagenicity, the treatment of their waste before disposal is required. In an attempt to prevent environmental contamination, ozonation has shown a promising technique due to its high oxidizing potential. Although the use of ozone for degradation of organic compounds come becoming increasingly common, little is known about the reaction intermediates and products formed during the ozonation of wastewater. Thus, it must ensure that these degradation products are not toxic. So is necessary the application of toxicological studies. This study investigated the kinetics of degradation of ethidium bromide and the efficiency degradation of the dye in aqueous solution in the presence and absence of catalysts ZnO, Al 2O3 and XAD -7 resin and identify the nature of toxic degradation products. In the application of ozonization, it was observed that the degradation of the compound is favored in acidic environment, which also depends on the concentration of ozone. The efficiency of degradation is dependent on the pH and the best results are in basic medium, with approximately 95% removal of the dye. In this technique, the degradation products in acidic and basic medium showed toxicity. The catalytic ozonation showed an increase in the degradation efficiency of ethidium bromide in the presence of ZnO catalyst in acid medium, at a dosage of 0.5 g L-1 , increasing the rate of degradation of 75.3% to 95.5 %, in that condition. The Al 2O3 and XAD-7 showed no significant catalytic activity . The toxicity tests performed for degradation products via catalytic ozonation presented nontoxic when compared to the results of ozonization without the presence of catalysts.
7

Efeito da interrupÃÃo abrupta do tratamento crÃnico com brometo de ipratrÃpio na resposta contrÃtil de traquÃias isoladas de ratos / Effect of ipratropium bromide abrupt withdrawal, after chronic treatment, in contractile response of isolated rat tracheas

Isabelle Maciel de Moraes 06 February 2004 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Visando estudar os efeitos da retirada abrupta apÃs o tratamento crÃnico com brometo de ipratrÃpio (BI) ratos machos pesando 200-250 g no inÃcio dos experimentos, foram introduzidos em uma caixa de acrÃlico e submetidos durante 7 minutos à inalaÃÃo de brometo de ipratrÃpio (600ÂM). Este procedimento se repetiu a cada quatro horas durante um perÃodo de 14 dias. Foram utilizadas duas cÃmaras de inalaÃÃo, uma para o grupo experimental (tratado com BI) e outra para o grupo controle (CONT, salina). Outro grupo de animais foi sensibilizado (SENS) e submetido ao mesmo protocolo de inalaÃÃo com BIque inalaram o brometo de ipratrÃpio e outra para os animais controle. Os animais SENS foram desafiados 24 horas antes do sacrifÃcio com inalaÃÃes do antÃgeno (OVA: 1mg/ml; 5mg/ml; 15/15 minutos; grupo DESF). Ao fim de uma Ãnica inalaÃÃo ou ao tÃrmino do perÃodo de tratamento crÃnico com BI os animais foram sacrificados 0, 4, 8, 12 horas apÃs a Ãltima inalaÃÃo e as traquÃias rapidamente removidas. ApÃs a dissecaÃÃo a traquÃia foi montada sob a forma de anÃis, em banho para ÃrgÃo isolado contendo 8 ml de soluÃÃo de Krebs-Henseleit (37ÂC, 95% O2, 5% CO2). Foram entÃo, confeccionadas curvas concentraÃÃo-efeito (CCE), ao carbacol (Cch), serotonina (5-HT), potÃssio (KCl), cÃlcio(CaCl2) e estÃmulo elÃtrico. As CCE ao Cch obtidas com traquÃias isoladas de ratos apÃs uma Ãnica inalaÃÃo de brometo de ipratrÃpio demonstrou desvio para a direita com significativo aumento da CE50[CE50x10-7M: CONT=1,78(1,32 â 2,32); BI 14,6(2,05 â 58,1), p<0,05). Imediatamente apÃs o fim do tratamento crÃnico as CCE ao Cch tambÃm apresentaram aumento significativo da CE50 [CE50x10-7M: CONT=2,33(1,25 â 4,32); BI=42,5(21,1 â 85,8), p<0,01). Nos experimentos realizados com traquÃias isoladas de ratos 4, 8 e 12 horas apÃs o fim do tratamento crÃnico ocorreu um progressivo aumento da contratilidade, com a resposta mÃxima(RM) atingindo um valor mÃximo 12 horas apÃs a supressÃo do tratamento crÃnico com BI (RM 12h: CONT= 1,69Â0,04, BI 2,64Â0,23 gF, p<0,01). Esta supersensibilidade caracterizada por aumento vertical, tambÃm se manifestou para outros agonistas e estÃmulos contrÃteis. Assim, ocorreu supersensibilidade para a serotonina (RM-12h: CONT=0,59Â0,04; BI=1,06Â0,10gF, p<0,01) potÃssio (RM: CONT= 0,70Â0,05; BI=1,27Â0,17 gF; p<0,01) e ao estÃmulo elÃtrico (RM: CONT=1,25Â0,07; BI=1,64Â0,06 gF; p<0,01). As CCE obtidas 12 horas apÃs o fim do tratamento crÃnico com BI, pela adiÃÃo de cÃlcio ao lÃquido de incubaÃÃo, apÃs ter sido obtida resposta contrÃtil ao KCl ou ao Cch, as quais avaliaram, respectiva e indiretamente, a entrada de cÃlcio via canais VOC e ROC demonstraram que a entrada de cÃlcio està facilitada em ambos os tipos de canal de cÃlcio estudados (RM-12h CaCl2/KCl: CONT=1,00Â0,09; BI=1,54Â0,19 gF; p<0,01) (RM-12h CaCl2/Cch: CONT=1,27Â0,10; BI=1,66Â0,05 gF; p<0,01). Nos experimentos realizados com animais desafiados, a supressÃo do tratamento crÃnico imediatamente apÃs Ãltima inalaÃÃo diminuiu a sensibilidade desviando para a direita a CCE ao Cch [CE50x10-7M: CONT=2,10(1,28 â 3,44); BI=17,12(4,37 â 67,05), p<0,01)]. Enquanto que, traquÃias isoladas de animais desafiados 12 horas apÃs o fim do tratamento ocorreu aumento significativo da contratilidade e da resposta mÃxima obtida para o carbacol (RM-12h: CONT=2,48Â0,19; BI=3,48Â0,13 gF; p<0,01). Estes resultados sugerem que a supressÃo do processo de inalaÃÃo crÃnica com BI induz um aumento de resposta contrÃtil ao Cch atingindo um valor mÃximo 12 horas apÃs a interrupÃÃo do tratamento crÃnico. Esta supersensibilidade 12 horas apÃs a supressÃo do tratamento crÃnico com BI, tambÃm foi manifestada para vÃrios outros agonistas, bem como para o estÃmulo elÃtrico. A supersensibilidade foi tambÃm detectada na resposta contrÃtil ao Cch, seguindo o mesmo protocolo experimental de interrupÃÃo do tratamento em traquÃias isoladas de ratos desafiados a OVA. Este aumento de resposta contrÃtil observado na musculatura traqueal de ratos, 12 horas tambÃm que a supersensibilidade està presente, apÃs o desafio antigÃnico, com incremento ainda maior na resposta contrÃtil quando comparada traquÃias isoladas de animais nÃo desafiados submetidos à retirada abrupta apÃs tratamento crÃnico com BI / In order to evaluate ipratropium bromide (IB) abrupt withdrawal effects after chronic treatment in isolated rat tracheas, male rats weighing 200-250g were placed in plastic chambers and submitted to inhalation of IB (600ÂM) during seven minutes. This protocol was repeated each four hours during 14 days. Two inhalation chambers were used, one with experimental group (IB inhalation) and the other with control group (CONT, saline). Another group was ovalbumin (OVA) actively sensitized (SZ) and submitted to the same protocol of inhalation. These animals were challenged 24hours before the beginning of the experiments by antigen inhalation (OVA: 1mg/ml; 5mg/ml; 15/15 minutes) (group DESF). At the end of IB treatment period the animals were killed and 0, 4, 8, 12 hours after the last inhalation the tracheas were quickly removed. After dissection the tracheal rings were transferred to a 8 ml organ bath containing Krebs-Henseleit solution mMol/l: NaCl 113.0; KCl 4.7; CaCl2.2H2O 1.2; KH2PO4 1.2; MgSO4.7H2O 1.2; NaHCO3 25.0; Glucose 11.0; 37 C; 95%O2/5%CO2). Concentration-effect curves (CEC) were constructed to carbachol (Cch), serotonin (5-HT), potassium (KCl), calcium (CaCl2) and electric stimulus. CEC to Cch obtained with tracheas isolated from rats submitted to only one IB inhalation showed shift to the right with an increase in the EC50 values [EC50x10-7M: CONT=1.78(1.32-2.32); IB=14.6(2.05-58.1) p<0.05]. Immediately after chronic treatment CEC to Cch also showed significant increase at EC50 level [EC50x10-7M: CONT=2.33(1.25-4.32); IB=42.5(21.1-85.8); p<0,01]. Experiments realized with isolated rats tracheas 4, 8, 12 hours after ended the IB chronic treatment showed a Cch maximum response (MR) progressive increase, reaching the greater value 12 hours after IB chronic treatment interruption [MR-12h: CONT=1.69Â0.04; IB=2.64Â0.23 gF, p<0.01). This kind of supersensitivity characterized by a vertical increase, was also obtained to other agonists and contractile stimulus. In this way the results showed supersensitivity to serotonin (MR-12h: CONT=0.59Â0.04; IB=1.06Â0.10; gF; p<0.01), potassium (MR-12h: CONT=0.70Â0.05; IB=1.27Â0.17; gF; p<0.01) and electric stimulus (MR-12h: CONT=1.25Â0.07; IB=1.64Â0.06; gF; p<0.01). Calcium CCE were obtained 12hours after the end of IB chronic treatment, after the addition of KCl or Cch in calcium free buffer. This kind of experiment measured, respsctively and indirectly the influx of calcium by voltage operated channelsVOC) and by receptor operated channels(ROC). The results demonstrated that influx of calcium was facilitated in both calcium channels studied in this work (MR-12h: CaCl2/KCl: CONT=1.00Â0.09; IB=1.54Â0.19; gF; p<0.01) (MR-12h: CaCl2/Cch; CONT= 1.27Â0.10; IB=1.66Â0.05; gF; p<0.01). The experiments with OVA challenged animals, realized immediately after the end of chronic treatment, showed a decreased in the sensibility. The CEC to Cch were shift to the right [EC50X10-7M: CONT=2.10(1.28-3.44); IB=17.13(4.37-67.05), P<0,01]. However, trachea isolated from rat challenged 12 hours after the end of the treatment, showed an increase in the contractility and in the MR obtained to carbachol (MR-12h: CONT=2.48Â0.19; IB=3.48Â0.13; gF; p<0,01). These data suggest that IB chronic inhalation process follow suppression induced an evident Cch contractile response increase in isolated rat trachea, reaching a maximum value 12 hours after interrupted IB chronic treatment abrupt suppression, was here demonstrated to several agonists and electric stimulus. Supersensitivity was also detected to carbachol contractile response through the same withdrawal experimental protocol in isolated tracheas from rats challenged with OVA. This increased contractile response obtained in rats tracheal smooth muscle, 12 hours after the end of ipratropium bromide chronic treatment, could be related with a component linked with the facilitation influx of calcium by voltage operated channels (VOC) and/or receptor operated channels (ROC)
8

Efeito sinergistico dos gases brometo de metila e oxido de etileno na esterilização de pimenta preta em grão

Rusig, Olavo, 1945- 15 July 2018 (has links)
Orientador: Fumio Yokoya / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-15T08:14:43Z (GMT). No. of bitstreams: 1 Rusig_Olavo_M.pdf: 1734891 bytes, checksum: 077b98e30f1219b56c8b03fa09dceb54 (MD5) Previous issue date: 1974 / Resumo: O objetivo deste trabalho foi estudar o efeito sinergístico na esterilização de pimenta do reino (Piper nigrum) preta, utilizando-se os gases óxido de etileno e brometo de metila. Foram feitos vários tratamentos na pimenta em função das seguintes variáveis: umidade relativa, temperatura de esterilização, concentração dos gases e tempo de exposição aos gases. Antes dos tratamentos, as amostras foram. condicionadas aproximadamente 17 horas em dessecadores, mantidos à umidades relativas de 30, 50 e 70 %. Para cada esterilização, efetuaram-se contagens microbiológicas total e de termofílicos a 32 e 55 ºC respectivamente, para os gases misturados e separados. O tempo de esterilização foi de 4, 8 e 17 horas. Os resultados mostraram que o tratamento com óxido de etileno na concentração de 360 mg/l não é suficiente para destruir às bactérias da pimenta preta. O tratamento com 2540 mg/l de brometo de metila foi eficiente na esterilização. A eficiência desses agentes cresceu com o aumento da umidade relativa e da temperatura. A proporção dos gases misturados mais eficiente na esterilização foi 1 de óxido de etileno para 10 de brometo de metila, sendo o tratamento mais interessante sob o ponto de vista prático o que constou de 58 mg/l de óxido de etileno, misturado com 540 mg/l de brometo de metila, por 17 horas de exposição / Abstract: The purpose of the present work was to study the synergistic effect of gaseous ethylene oxide and methyl bromide on the sterilization of black pepper (Piper nigrum). Various treatments of the pepper were carried out employing following variables: relative humidity, sterilization temperature, concentration of gases and exposure time to gases. Before the treatments, the samples were conditioned for approximately 17 hours in desiccators maintained at relative humidities of 30, 50 and 70 %. For each sterilization microbiological total counts and thermophylic bacteria counts at 32 and 55 ºC respectively were carried out, employing individual gases and their mixtures. Sterilization times were 4, 8 and 17 hours. The results showed that the treatment with ethylene oxide at a concentration of 360 mg/l was not efficient in destroying the bacteria of black pepper. The treatment with 2540 mg/l of methyl bromide was efficient in the sterilization. The efficiency of these agents improved with the increase of the relative humidity and temperature. The most efficient proportion of the mixed gases for sterilization was 1 part of ethylene oxide to 10 parts of methyl bromide, the most interesting treatment from the practical point of view being that with a mixture containing 58 mg/l of ethylene oxide and 540 mg/l of methyl bromide with 17 hours of exposure / Mestrado / Mestre em Tecnologia de Alimentos
9

Efeitos da deleção do gene para conexina 32 sobre aspectos pró e anti-inflamatórios no modelo de desmielinização tóxica do brometo de etídio / Effects of deletion of the connexin 32 gene on pro and antiinflammatories effects in the ethidium bromide toxic demyelination model

Hosomi, Fernando Yutaka Moniwa 10 May 2010 (has links)
As junções comunicantes são estruturas celulares que permitem o trânsito de moléculas entre as células, desempenhando funções de sinalização e transporte intercelular. São formadas por proteínas denominadas conexinas e representam estruturas-chave no funcionamento de tecidos altamente complexos e integrados, como o sistema nervoso central (SNC). O presente estudo avalia os efeitos da deleção da conexina 32 (Cx32) na inflamação e regeneração/cicatrização do SNC após 1, 3, 7, 10 e 20 dias pós-injeção intracerebral de brometo de etídio em camundongos deletados para Cx32 e camundongos normais. Para tanto, quantificou-se a expressão dos genes para fator de necrose tumoral alfa (TNF&alpha;), fator de crescimento transformador beta 1 (TGF&beta;), metaloproteinase 3 (MMP3), metaloproteinase 9 (MMP9) e inibidor tecidual de metaloproteinases 1 (TIMP1), através de PCR em tempo real. Os resultados indicam variáveis diferenças no padrão de expressão, incluindo variação na expressão de todos os genes pesquisados no período de 3 dias pós-injeção, ápice dos mecanismos de inflamação aguda. Estes resultados sugerem que a conexina 32 pode desempenhar funções importantes na sinalização molecular do processo inflamatório e regenerativo/cicatricial do sistema nervoso central. / Gap junctions are cellular structures that allow transit of molecules between cells, performing intercellular signaling and transportation. They are formed by proteins denominated connexins and represent key structures in highly complex and integrated tissues, such as the central nervous system (CNS). The present study evaluates the effects of connexin 32 (Cx32) deletion upon CNS inflammation and egeneration/cicatrization after 1, 3, 7, 10 and 20 days after intracerebral injection of ethidium bromide in Cx32 Knock Out and normal mice. To accomplish so, Real Time PCR gene expression quantification was performed uppon tumour necrosis factor alpha (TNF&alpha;), transforming growth factor beta 1 (TGF&beta;), metalloproteinase 3 (MMP3), metalloproteinase 9 (MMP9) and tissue inhibitor of metalloproteinases 1(TIMP1) genes. Results indicate variable differences in the expression pattern, including difference in expression of all evaluated genes in the 3 days after injection period, apex of the acute inflammation mechanisms. These results suggest that Cx32 may perform important functions on molecular inflammatory and regenerative/cicatrization signalling in the CNS.
10

Efeitos da deleção do gene para conexina 32 sobre aspectos pró e anti-inflamatórios no modelo de desmielinização tóxica do brometo de etídio / Effects of deletion of the connexin 32 gene on pro and antiinflammatories effects in the ethidium bromide toxic demyelination model

Fernando Yutaka Moniwa Hosomi 10 May 2010 (has links)
As junções comunicantes são estruturas celulares que permitem o trânsito de moléculas entre as células, desempenhando funções de sinalização e transporte intercelular. São formadas por proteínas denominadas conexinas e representam estruturas-chave no funcionamento de tecidos altamente complexos e integrados, como o sistema nervoso central (SNC). O presente estudo avalia os efeitos da deleção da conexina 32 (Cx32) na inflamação e regeneração/cicatrização do SNC após 1, 3, 7, 10 e 20 dias pós-injeção intracerebral de brometo de etídio em camundongos deletados para Cx32 e camundongos normais. Para tanto, quantificou-se a expressão dos genes para fator de necrose tumoral alfa (TNF&alpha;), fator de crescimento transformador beta 1 (TGF&beta;), metaloproteinase 3 (MMP3), metaloproteinase 9 (MMP9) e inibidor tecidual de metaloproteinases 1 (TIMP1), através de PCR em tempo real. Os resultados indicam variáveis diferenças no padrão de expressão, incluindo variação na expressão de todos os genes pesquisados no período de 3 dias pós-injeção, ápice dos mecanismos de inflamação aguda. Estes resultados sugerem que a conexina 32 pode desempenhar funções importantes na sinalização molecular do processo inflamatório e regenerativo/cicatricial do sistema nervoso central. / Gap junctions are cellular structures that allow transit of molecules between cells, performing intercellular signaling and transportation. They are formed by proteins denominated connexins and represent key structures in highly complex and integrated tissues, such as the central nervous system (CNS). The present study evaluates the effects of connexin 32 (Cx32) deletion upon CNS inflammation and egeneration/cicatrization after 1, 3, 7, 10 and 20 days after intracerebral injection of ethidium bromide in Cx32 Knock Out and normal mice. To accomplish so, Real Time PCR gene expression quantification was performed uppon tumour necrosis factor alpha (TNF&alpha;), transforming growth factor beta 1 (TGF&beta;), metalloproteinase 3 (MMP3), metalloproteinase 9 (MMP9) and tissue inhibitor of metalloproteinases 1(TIMP1) genes. Results indicate variable differences in the expression pattern, including difference in expression of all evaluated genes in the 3 days after injection period, apex of the acute inflammation mechanisms. These results suggest that Cx32 may perform important functions on molecular inflammatory and regenerative/cicatrization signalling in the CNS.

Page generated in 0.0693 seconds