• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estabilidade de taludes

Tonus, Bianca Penteado de Almeida 26 November 2009 (has links)
No description available.
2

Estudo de difusão de In e Pd em [alfa]-Ti utilizando a técnica de espectrometria de retroespalhamento de Rutherford e canalização

Soares, Marcio Ronaldo Farias January 1998 (has links)
O objetivo da presente dissertação é o estudo de difusão de In e Pd na matriz de a-Ti. O interesse deste estudo baseia-se na investigação sistemática, realizada pelo grupo de Implantação Iônica, de difusão de impurezas substitucionais em a-Ti com o fim de determinar uma relação entre tamanho, valência e solubilidade e os respectivos coeficientes de difusão. Considerações de tamanho, diferença de valência e solubilidade indicam que o In deverá difundir substitucionalmente. Por outro lado, não está claro qual será o mecanismo de difusão do Pd, pois a sua solubilidade não é muito alta e seu raio atômico é menor que o da matriz. A dependência do coeficiente de difusão desses dois elementos com a temperatura foi estudada entre 823 e 1073 K no caso do In, e entre 673 e 1073 K no caso do Pd. Em ambos os casos, a técnica de RBS foi utilizada para determinar os perfis de concentração. Esta técnica tem uma alta resolução em profundidade (tipicamente 10 nm), o que permite a determinação das baixas difusividades esperadas no presente experimento (D ≤ 10-17 m² s-¹). Adicionalmente, utilizamos para o caso do Pd a técnica de canalização, com a finalidade de determinar o grau de substitucionalidade dos átomos de Pd, tanto imediatamente após a implantação, quanto depois de efetuados os recozimentos e, portanto, determinar o mecanismo de difusão do mesmo em α - Ti. No caso do In, os coeficientes de difusão seguem uma lei de Arrhenius com parâmetros de difusão Q = (260 ± 10) kJ/mol e Do = (2,0 ± 1,3) x 10-6 m² s-¹ , valores estes, típicos de um comportamento difusivo substitucional. No entanto, para o Pd, os coeficientes de difusão também seguem um comportamento tipo Arrhenius, com Q = (264 ± 9) kJ/mol e Do = (2,8 ± 1,3) x 10-3 m² s-¹. Quando se comparam os resultados do Pd com outros substitucionais, tais como Pb, Au, Sn e In, os resultados indicam que o Pd é um difusor rápido, porém mais lento que os intersticiais do tipo Fe, Co ou Cu. Por outro lado, os experimentos de canalização indicam que no intervalo de temperatura estudado, 30% dos átomos de Pd ficam em posição intersticial na rede. Isto é um forte indício de que o mecanismo de difusão é do tipo misto.
3

Avaliação de tubos de concreto reforçados com fibras de aço segundo a NBR 8890 /

Fugii, Ana Paula. January 2008 (has links)
Orientador: Jorge Luís Akasaki / Banca: Jefferson Sidney Camacho / Banca: Antonio Domingues Figueiredo / Resumo: Os tubos de concreto são utilizados em larga escala nas canalizações dos sistemas de abastecimento de água em diâmetros superiores a 400 mm, esgoto sanitário, drenagem pluvial, bueiro e travessia. Suas vantagens e aplicabilidade têm motivado diversas pesquisas sobre esse produto, dentre as quais podemos destacar a utilização de tubos de concreto reforçados com fibras de aço em substituição total da armadura. As fibras de aço quando adicionadas ao concreto melhoram algumas propriedades, tais como: tenacidade, limitação de abertura de fissuras e resistência ao impacto. A pesquisa objetiva analisar o comportamento mecânico de protótipos de tubos de concreto confeccionados com diferentes teores de adições de fibras de aço, tais como: 10 kg/m3, 15 kg/m3, 20 kg/m3, 25 kg/m3 e 30 kg/m3, em substituição total da armadura. Também foram fabricados tubos de concreto simples e armados para uma análise comparativa do comportamento mecânico entre aqueles e os tubos com fibras. Os tubos de concreto possuem 600 mm de diâmetro nominal e 1,5 m de comprimento, destinados aos sistemas de drenagem de águas pluviais. As fibras de aço utilizadas possuem fator de forma igual a 75 e apresentam as seguintes características: 60 mm de comprimento médio e 0,80 mm de diâmetro médio. Os corpos-de-prova cilíndricos foram submetidos aos ensaios: resistência à compressão axial, resistência à tração na compressão diametral, e os corpos-de- prova prismáticos foram submetidos aos ensaios de tenacidade enquanto os tubos de concreto foram submetidos aos ensaios: resistência à compressão diametral e absorção de água (amostras retiradas dos tubos após ensaio de compressão diametral). Dos ensaios realizados se destaca o ensaio de compressão diametral pelo fato... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The concrete pipe is widely used in plumbing systems in water supplying in higher diameters 400 mm, sewage, water rain drainage, storm drain and crossing. Its advantages and functions have motivated a lot of researches about this product, among them can point out used concrete pipes reinforced with steel fibers replacing the conventional framework. The steel fibers when added concrete improvement some properties, such as: flexural toughness, limitation crack width and high strain rates strength. The current text refers to a study developed to evaluate the mechanical behavior of manufactured prototypes with steel fibers added in different contents, such as: 10 kg/m3, 15 kg/m3, 20 kg/m3, 25 kg/m3 e 30 kg/m3, replacing the conventional framework. Also were manufactured simple concrete pipes and concrete pipes with framework for analysis to compare the mechanical behavior between that one and steel fibers. The pipes used have 600 mm nominal diameter and 1,5 m length, used in systems in water rain drainage. The steel fibers used have aspect ratio 75 and present characteristics: 60 mm medium length and 0,80 mm medium diameter. The circular specimens were submitted the testing for: compressive strength, tensile strength by diametrical compressive, and the rectangular specimens were submittes the testing for flexural toughness while the concrete pipes were submitted the testing for: diametrical compressive strength and absorption of water (sample retreat of pipes after the testing for diametrical compressive strength). The testing for realized to point for diametrical compressive strength because the testing for the same concrete pipe and all particular characteristics for observed. The Brazilian specification NBR 8890 (ABNT, 2007) specify the testing for diametrical compressive... (Complete abstract click electronic access below) / Mestre
4

Estudo do poder de freamento de He, Li, Eu e Bi canalizados em alvos de Si cristalino

Azevedo, Gustavo de Medeiros January 2000 (has links)
Neste trabalho, foi realizado um estudo experimental sistemático da perda de energia de íons canalizados ao longo das direções h100i , h111i e h110i de cristais de Si. Foram abordados dois aspectos distintos, porém correlatos, do problema. No primeiro tópico, estudamos o poder de freamento de íons pesados (Eu e Bi) com energias entre 15 e 50 keV, para os quais o mecanismo predominante de perda de energia é o freamento nuclear. O segundo tópico está relacionado ao freamento de íons leves (He e Li) com energias no intervalo entre 0.3 e 8 MeV. Neste caso, os íons perdem energia, predominantemente, em colisões com elétrons. O estudo do freamento dos íons pesados foi realizado de maneira indireta, pela comparação dos perfis de concentração de Eu e Bi implantados em direção canalizada com as previsões do programa MARLOWE, que simula a interação de feixes de íons com alvos sólidos. Nós observamos pela primeira vez, em implantações em direção canalizada, o chamado efeito Z1, ou seja, a deformação das núvens eletrônicas do projétil e do alvo em colisões binárias de baixa energia. Enquanto nossos dados para implantações de Bi são muito bem reproduzidas pelo MARLOWE, os perfis de Eu apresentam caudas mais profundas que as preditas por este programa. Além disso nós demonstramos que este comportamento é explicado por cálculos ab initio de estrutura molecular baseados na Teoria Funcional da Densidade (DFT). Com relação os íons leves, a perda de energia foi obtida pela técnica de retroespalhamento Rutherford em amostras do tipo SIMOX, que consistem em uma camada de Si monocristalino de 200 nm sobre uma camada de 500 nm de SiO2 enterrada numa matriz de Sih100i . Com esta técnica nós realizamos medidas da perda de energia como função da energia e do ângulo de incidência do feixe com relação á direção de canalização. A análise teórica dos resultados foi realizada por intermédio de simulações das trajetórias canalizadas e de cálculos da dependência da perda de energia com o parâmetro de impacto. Estas comparações permitiram determinar o papel desempenhado pelos diversos mecanismos de perda de energia envolvidos no freamento dos íons canalizados. / In this work we have performed a systematic sudy of the energy loss of channeled ions along the h100i , h111i and h110i directions of Si single crystals. Two different, but related, topics of the problem were investigated. On the first topic we have studied the stopping powers of heavy ions (Eu and Bi) with energies ranging between 15 and 50 keV, for which the main slowing down mechanism is the nuclear stopping power. The second topic is related to the slowing down of light ions (He and Li) with energies ranging between 0.3 and 8 MeV. In this case, the projectile energy is lost mainly in electronic collisions. The study of the slowing down of channeled heavy ions was performed in an indirect way, by comparing the depth profiles of Eu and Bi ions implanted under channeling conditions with calculations with the program MARLOWE which simulates the interactions of ion beams with solid targets. We have observed for the first time in channeling implantations the Z1 effect, namely, the deformation of the periphery of the electronic clouds of the projectile and target in low energy atomic collisions. While our data for Bi implantations are very well reproduced by MARLOWE predictions the Eu profiles present long tails that go farther in the Si bulk than predicted by MARLOWE. Furthermore, we have demostrated that this behavior is explained in terms of molecular structure ab initio calculations based on the Density Fuctional Theory (DFT). Concerning the light ions, the stopping powers were measured by the Rutherford Backscattering technique with SIMOX samples that consist on a Si single crystal layer 200nm thick on the top of a 5000 nm thick SiO2 layer buried on a Sih100i single cristal. With this technique we have measured both the energy and the angular dependency of the the channeling stopping power. The theoretical analysis of the results was performed by means of computer simulations of the channeled trajectories and in calculatios of the impact parameter dependent energy loss. These comparisons allowed us to determine the relative role played by the energy loss processes under channeling conditions
5

Estudo de difusão de In e Pd em [alfa]-Ti utilizando a técnica de espectrometria de retroespalhamento de Rutherford e canalização

Soares, Marcio Ronaldo Farias January 1998 (has links)
O objetivo da presente dissertação é o estudo de difusão de In e Pd na matriz de a-Ti. O interesse deste estudo baseia-se na investigação sistemática, realizada pelo grupo de Implantação Iônica, de difusão de impurezas substitucionais em a-Ti com o fim de determinar uma relação entre tamanho, valência e solubilidade e os respectivos coeficientes de difusão. Considerações de tamanho, diferença de valência e solubilidade indicam que o In deverá difundir substitucionalmente. Por outro lado, não está claro qual será o mecanismo de difusão do Pd, pois a sua solubilidade não é muito alta e seu raio atômico é menor que o da matriz. A dependência do coeficiente de difusão desses dois elementos com a temperatura foi estudada entre 823 e 1073 K no caso do In, e entre 673 e 1073 K no caso do Pd. Em ambos os casos, a técnica de RBS foi utilizada para determinar os perfis de concentração. Esta técnica tem uma alta resolução em profundidade (tipicamente 10 nm), o que permite a determinação das baixas difusividades esperadas no presente experimento (D ≤ 10-17 m² s-¹). Adicionalmente, utilizamos para o caso do Pd a técnica de canalização, com a finalidade de determinar o grau de substitucionalidade dos átomos de Pd, tanto imediatamente após a implantação, quanto depois de efetuados os recozimentos e, portanto, determinar o mecanismo de difusão do mesmo em α - Ti. No caso do In, os coeficientes de difusão seguem uma lei de Arrhenius com parâmetros de difusão Q = (260 ± 10) kJ/mol e Do = (2,0 ± 1,3) x 10-6 m² s-¹ , valores estes, típicos de um comportamento difusivo substitucional. No entanto, para o Pd, os coeficientes de difusão também seguem um comportamento tipo Arrhenius, com Q = (264 ± 9) kJ/mol e Do = (2,8 ± 1,3) x 10-3 m² s-¹. Quando se comparam os resultados do Pd com outros substitucionais, tais como Pb, Au, Sn e In, os resultados indicam que o Pd é um difusor rápido, porém mais lento que os intersticiais do tipo Fe, Co ou Cu. Por outro lado, os experimentos de canalização indicam que no intervalo de temperatura estudado, 30% dos átomos de Pd ficam em posição intersticial na rede. Isto é um forte indício de que o mecanismo de difusão é do tipo misto.
6

Avaliação de tubos de concreto reforçados com fibras de aço segundo a NBR 8890

Fugii, Ana Paula [UNESP] 12 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-12Bitstream added on 2014-06-13T18:21:13Z : No. of bitstreams: 1 fugii_ap_me_ilha_prot.pdf: 6559082 bytes, checksum: e1ddcb7044b10a47da7e5f917d6bce83 (MD5) / Os tubos de concreto são utilizados em larga escala nas canalizações dos sistemas de abastecimento de água em diâmetros superiores a 400 mm, esgoto sanitário, drenagem pluvial, bueiro e travessia. Suas vantagens e aplicabilidade têm motivado diversas pesquisas sobre esse produto, dentre as quais podemos destacar a utilização de tubos de concreto reforçados com fibras de aço em substituição total da armadura. As fibras de aço quando adicionadas ao concreto melhoram algumas propriedades, tais como: tenacidade, limitação de abertura de fissuras e resistência ao impacto. A pesquisa objetiva analisar o comportamento mecânico de protótipos de tubos de concreto confeccionados com diferentes teores de adições de fibras de aço, tais como: 10 kg/m3, 15 kg/m3, 20 kg/m3, 25 kg/m3 e 30 kg/m3, em substituição total da armadura. Também foram fabricados tubos de concreto simples e armados para uma análise comparativa do comportamento mecânico entre aqueles e os tubos com fibras. Os tubos de concreto possuem 600 mm de diâmetro nominal e 1,5 m de comprimento, destinados aos sistemas de drenagem de águas pluviais. As fibras de aço utilizadas possuem fator de forma igual a 75 e apresentam as seguintes características: 60 mm de comprimento médio e 0,80 mm de diâmetro médio. Os corpos-de-prova cilíndricos foram submetidos aos ensaios: resistência à compressão axial, resistência à tração na compressão diametral, e os corpos-de- prova prismáticos foram submetidos aos ensaios de tenacidade enquanto os tubos de concreto foram submetidos aos ensaios: resistência à compressão diametral e absorção de água (amostras retiradas dos tubos após ensaio de compressão diametral). Dos ensaios realizados se destaca o ensaio de compressão diametral pelo fato... / The concrete pipe is widely used in plumbing systems in water supplying in higher diameters 400 mm, sewage, water rain drainage, storm drain and crossing. Its advantages and functions have motivated a lot of researches about this product, among them can point out used concrete pipes reinforced with steel fibers replacing the conventional framework. The steel fibers when added concrete improvement some properties, such as: flexural toughness, limitation crack width and high strain rates strength. The current text refers to a study developed to evaluate the mechanical behavior of manufactured prototypes with steel fibers added in different contents, such as: 10 kg/m3, 15 kg/m3, 20 kg/m3, 25 kg/m3 e 30 kg/m3, replacing the conventional framework. Also were manufactured simple concrete pipes and concrete pipes with framework for analysis to compare the mechanical behavior between that one and steel fibers. The pipes used have 600 mm nominal diameter and 1,5 m length, used in systems in water rain drainage. The steel fibers used have aspect ratio 75 and present characteristics: 60 mm medium length and 0,80 mm medium diameter. The circular specimens were submitted the testing for: compressive strength, tensile strength by diametrical compressive, and the rectangular specimens were submittes the testing for flexural toughness while the concrete pipes were submitted the testing for: diametrical compressive strength and absorption of water (sample retreat of pipes after the testing for diametrical compressive strength). The testing for realized to point for diametrical compressive strength because the testing for the same concrete pipe and all particular characteristics for observed. The Brazilian specification NBR 8890 (ABNT, 2007) specify the testing for diametrical compressive... (Complete abstract click electronic access below)
7

Estudo do poder de freamento de He, Li, Eu e Bi canalizados em alvos de Si cristalino

Azevedo, Gustavo de Medeiros January 2000 (has links)
Neste trabalho, foi realizado um estudo experimental sistemático da perda de energia de íons canalizados ao longo das direções h100i , h111i e h110i de cristais de Si. Foram abordados dois aspectos distintos, porém correlatos, do problema. No primeiro tópico, estudamos o poder de freamento de íons pesados (Eu e Bi) com energias entre 15 e 50 keV, para os quais o mecanismo predominante de perda de energia é o freamento nuclear. O segundo tópico está relacionado ao freamento de íons leves (He e Li) com energias no intervalo entre 0.3 e 8 MeV. Neste caso, os íons perdem energia, predominantemente, em colisões com elétrons. O estudo do freamento dos íons pesados foi realizado de maneira indireta, pela comparação dos perfis de concentração de Eu e Bi implantados em direção canalizada com as previsões do programa MARLOWE, que simula a interação de feixes de íons com alvos sólidos. Nós observamos pela primeira vez, em implantações em direção canalizada, o chamado efeito Z1, ou seja, a deformação das núvens eletrônicas do projétil e do alvo em colisões binárias de baixa energia. Enquanto nossos dados para implantações de Bi são muito bem reproduzidas pelo MARLOWE, os perfis de Eu apresentam caudas mais profundas que as preditas por este programa. Além disso nós demonstramos que este comportamento é explicado por cálculos ab initio de estrutura molecular baseados na Teoria Funcional da Densidade (DFT). Com relação os íons leves, a perda de energia foi obtida pela técnica de retroespalhamento Rutherford em amostras do tipo SIMOX, que consistem em uma camada de Si monocristalino de 200 nm sobre uma camada de 500 nm de SiO2 enterrada numa matriz de Sih100i . Com esta técnica nós realizamos medidas da perda de energia como função da energia e do ângulo de incidência do feixe com relação á direção de canalização. A análise teórica dos resultados foi realizada por intermédio de simulações das trajetórias canalizadas e de cálculos da dependência da perda de energia com o parâmetro de impacto. Estas comparações permitiram determinar o papel desempenhado pelos diversos mecanismos de perda de energia envolvidos no freamento dos íons canalizados. / In this work we have performed a systematic sudy of the energy loss of channeled ions along the h100i , h111i and h110i directions of Si single crystals. Two different, but related, topics of the problem were investigated. On the first topic we have studied the stopping powers of heavy ions (Eu and Bi) with energies ranging between 15 and 50 keV, for which the main slowing down mechanism is the nuclear stopping power. The second topic is related to the slowing down of light ions (He and Li) with energies ranging between 0.3 and 8 MeV. In this case, the projectile energy is lost mainly in electronic collisions. The study of the slowing down of channeled heavy ions was performed in an indirect way, by comparing the depth profiles of Eu and Bi ions implanted under channeling conditions with calculations with the program MARLOWE which simulates the interactions of ion beams with solid targets. We have observed for the first time in channeling implantations the Z1 effect, namely, the deformation of the periphery of the electronic clouds of the projectile and target in low energy atomic collisions. While our data for Bi implantations are very well reproduced by MARLOWE predictions the Eu profiles present long tails that go farther in the Si bulk than predicted by MARLOWE. Furthermore, we have demostrated that this behavior is explained in terms of molecular structure ab initio calculations based on the Density Fuctional Theory (DFT). Concerning the light ions, the stopping powers were measured by the Rutherford Backscattering technique with SIMOX samples that consist on a Si single crystal layer 200nm thick on the top of a 5000 nm thick SiO2 layer buried on a Sih100i single cristal. With this technique we have measured both the energy and the angular dependency of the the channeling stopping power. The theoretical analysis of the results was performed by means of computer simulations of the channeled trajectories and in calculatios of the impact parameter dependent energy loss. These comparisons allowed us to determine the relative role played by the energy loss processes under channeling conditions
8

Estudo do poder de freamento de He, Li, Eu e Bi canalizados em alvos de Si cristalino

Azevedo, Gustavo de Medeiros January 2000 (has links)
Neste trabalho, foi realizado um estudo experimental sistemático da perda de energia de íons canalizados ao longo das direções h100i , h111i e h110i de cristais de Si. Foram abordados dois aspectos distintos, porém correlatos, do problema. No primeiro tópico, estudamos o poder de freamento de íons pesados (Eu e Bi) com energias entre 15 e 50 keV, para os quais o mecanismo predominante de perda de energia é o freamento nuclear. O segundo tópico está relacionado ao freamento de íons leves (He e Li) com energias no intervalo entre 0.3 e 8 MeV. Neste caso, os íons perdem energia, predominantemente, em colisões com elétrons. O estudo do freamento dos íons pesados foi realizado de maneira indireta, pela comparação dos perfis de concentração de Eu e Bi implantados em direção canalizada com as previsões do programa MARLOWE, que simula a interação de feixes de íons com alvos sólidos. Nós observamos pela primeira vez, em implantações em direção canalizada, o chamado efeito Z1, ou seja, a deformação das núvens eletrônicas do projétil e do alvo em colisões binárias de baixa energia. Enquanto nossos dados para implantações de Bi são muito bem reproduzidas pelo MARLOWE, os perfis de Eu apresentam caudas mais profundas que as preditas por este programa. Além disso nós demonstramos que este comportamento é explicado por cálculos ab initio de estrutura molecular baseados na Teoria Funcional da Densidade (DFT). Com relação os íons leves, a perda de energia foi obtida pela técnica de retroespalhamento Rutherford em amostras do tipo SIMOX, que consistem em uma camada de Si monocristalino de 200 nm sobre uma camada de 500 nm de SiO2 enterrada numa matriz de Sih100i . Com esta técnica nós realizamos medidas da perda de energia como função da energia e do ângulo de incidência do feixe com relação á direção de canalização. A análise teórica dos resultados foi realizada por intermédio de simulações das trajetórias canalizadas e de cálculos da dependência da perda de energia com o parâmetro de impacto. Estas comparações permitiram determinar o papel desempenhado pelos diversos mecanismos de perda de energia envolvidos no freamento dos íons canalizados. / In this work we have performed a systematic sudy of the energy loss of channeled ions along the h100i , h111i and h110i directions of Si single crystals. Two different, but related, topics of the problem were investigated. On the first topic we have studied the stopping powers of heavy ions (Eu and Bi) with energies ranging between 15 and 50 keV, for which the main slowing down mechanism is the nuclear stopping power. The second topic is related to the slowing down of light ions (He and Li) with energies ranging between 0.3 and 8 MeV. In this case, the projectile energy is lost mainly in electronic collisions. The study of the slowing down of channeled heavy ions was performed in an indirect way, by comparing the depth profiles of Eu and Bi ions implanted under channeling conditions with calculations with the program MARLOWE which simulates the interactions of ion beams with solid targets. We have observed for the first time in channeling implantations the Z1 effect, namely, the deformation of the periphery of the electronic clouds of the projectile and target in low energy atomic collisions. While our data for Bi implantations are very well reproduced by MARLOWE predictions the Eu profiles present long tails that go farther in the Si bulk than predicted by MARLOWE. Furthermore, we have demostrated that this behavior is explained in terms of molecular structure ab initio calculations based on the Density Fuctional Theory (DFT). Concerning the light ions, the stopping powers were measured by the Rutherford Backscattering technique with SIMOX samples that consist on a Si single crystal layer 200nm thick on the top of a 5000 nm thick SiO2 layer buried on a Sih100i single cristal. With this technique we have measured both the energy and the angular dependency of the the channeling stopping power. The theoretical analysis of the results was performed by means of computer simulations of the channeled trajectories and in calculatios of the impact parameter dependent energy loss. These comparisons allowed us to determine the relative role played by the energy loss processes under channeling conditions
9

Estudo de difusão de In e Pd em [alfa]-Ti utilizando a técnica de espectrometria de retroespalhamento de Rutherford e canalização

Soares, Marcio Ronaldo Farias January 1998 (has links)
O objetivo da presente dissertação é o estudo de difusão de In e Pd na matriz de a-Ti. O interesse deste estudo baseia-se na investigação sistemática, realizada pelo grupo de Implantação Iônica, de difusão de impurezas substitucionais em a-Ti com o fim de determinar uma relação entre tamanho, valência e solubilidade e os respectivos coeficientes de difusão. Considerações de tamanho, diferença de valência e solubilidade indicam que o In deverá difundir substitucionalmente. Por outro lado, não está claro qual será o mecanismo de difusão do Pd, pois a sua solubilidade não é muito alta e seu raio atômico é menor que o da matriz. A dependência do coeficiente de difusão desses dois elementos com a temperatura foi estudada entre 823 e 1073 K no caso do In, e entre 673 e 1073 K no caso do Pd. Em ambos os casos, a técnica de RBS foi utilizada para determinar os perfis de concentração. Esta técnica tem uma alta resolução em profundidade (tipicamente 10 nm), o que permite a determinação das baixas difusividades esperadas no presente experimento (D ≤ 10-17 m² s-¹). Adicionalmente, utilizamos para o caso do Pd a técnica de canalização, com a finalidade de determinar o grau de substitucionalidade dos átomos de Pd, tanto imediatamente após a implantação, quanto depois de efetuados os recozimentos e, portanto, determinar o mecanismo de difusão do mesmo em α - Ti. No caso do In, os coeficientes de difusão seguem uma lei de Arrhenius com parâmetros de difusão Q = (260 ± 10) kJ/mol e Do = (2,0 ± 1,3) x 10-6 m² s-¹ , valores estes, típicos de um comportamento difusivo substitucional. No entanto, para o Pd, os coeficientes de difusão também seguem um comportamento tipo Arrhenius, com Q = (264 ± 9) kJ/mol e Do = (2,8 ± 1,3) x 10-3 m² s-¹. Quando se comparam os resultados do Pd com outros substitucionais, tais como Pb, Au, Sn e In, os resultados indicam que o Pd é um difusor rápido, porém mais lento que os intersticiais do tipo Fe, Co ou Cu. Por outro lado, os experimentos de canalização indicam que no intervalo de temperatura estudado, 30% dos átomos de Pd ficam em posição intersticial na rede. Isto é um forte indício de que o mecanismo de difusão é do tipo misto.
10

Canalização: fenótipos robustos como consequência de características da rede de regulação gênica / Canalization: phenotype robustness as consequence of characteristics of the gene regulatory network

Patricio, Vitor Hugo Louzada 20 April 2011 (has links)
Em sistemas biológicos, o estudo da estabilidade das redes de regulação gênica é visto como uma contribuição importante que a Matemática pode proporcionar a pesquisas sobre câncer e outras doenças genéticas. Neste trabalho, utilizamos o conceito de ``canalização\'\' como sinônimo de estabilidade em uma rede biológica. Como as características de uma rede de regulação canalizada ainda são superficialmente compreendidas, estudamos esse conceito sob o ponto de vista computacional: propomos um modelo matemático simplificado para descrever o fenômeno e realizamos algumas análises sobre o mesmo. Mais especificamente, a estabilidade da maior bacia de atração das redes Booleanas - um clássico paradigma para a modelagem de redes de regulação - é analisada. Os resultados indicam que a estabilidade da maior bacia de atração está relacionada com dados biológicos sobre o crescimento de colônias de leveduras e que considerações sobre a interação entre as funções Booleanas e a topologia da rede devem ser realizadas conjuntamente na análise de redes estáveis. / In biological systems, the study of gene regulatory networks stability is seen as an important contribution that Mathematics can make to cancer research and that of other genetic diseases. In this work, we consider the concept of ``canalization\'\' as a consequence of stability in gene regulatory networks. The characteristics of canalized regulatory networks are superficially understood. Hence, we study the canalization concept under a computational framework: a simplified model is proposed to describe the phenomenon using Boolean Networks - a classical paradigm to modeling regulatory networks. Specifically, the stability of the largest basin of attraction in gene regulatory networks is analyzed. Our results indicate that the stability of the largest basin of attraction is related to biological data on growth of yeast colonies, and that thoughts about the interaction between Boolean functions and network topologies must be given in the analysis of stable networks.

Page generated in 0.0638 seconds