• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 246
  • 9
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 1
  • 1
  • Tagged with
  • 266
  • 161
  • 65
  • 63
  • 55
  • 41
  • 38
  • 36
  • 32
  • 25
  • 23
  • 23
  • 22
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Dinâmica de sistemas quânticos : átomos em cavidades e íons aprisionados

Freitas, Dagoberto da Silva 19 September 2002 (has links)
Orientador: Jose Antonio Roversi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T17:45:47Z (GMT). No. of bitstreams: 1 Freitas_DagobertodaSilva_D.pdf: 2268838 bytes, checksum: d10685b1f660f7d8ce86950bf96a0421 (MD5) Previous issue date: 2002 / Resumo: Nessa tese, estudamos a dinâmica de sistemas quânticos: átomos em cavidades e íons aprisionados. Para átomos em cavidades ( QED ) , focalizamos a nossa atenção na dinâmica do campo preparado em uma superposição de estados coerentes e em uma mistura estatística. Nesse sistema, usando o modelo Jaynes-Cummings dependente da intensidade (DNJCM) discutimos alguns aspectos da dinâmica átomo-campo com uma interação tipo Jaynes-Cummings (JCM) e mostramos que para o campo preparado em um estado de 'gato par', esse será encontrado 'próximo' de um estado de gato ímpar, para o primeiro tempo de 'revival' e nesse mesmo tempo o átomo inicialmente no estado excitado estará 'próximo' do estado fundamental; esse comportamento é uma conseqiiência da conservação da paridade do sistema total. Um outro aspecto da dinâmica do campo discutido aqui, foi a purificação estado do campo inicialmente preparado em uma mistura estatística para a metade do primeiro tempo de 'revival'. Como pode ser observado na dinâmica da função Q, não obtemos um purificação do campo porque ambos os estados coerentes ?a > e 1- a > não produzem estados puros idênticos para esse tempo e consequentemente não teremos uma purificação. No sistema de íons aprisionados, discutimos a geração de estados não clássicos e os efeitos de perda de coerência nessa geração. Para explicar o efeito de perda de coerência, propuzemos um modelo que leva em consideração o acoplamento entre modos cruzados do movimento do íon. Esse acoplamento pode ser induzido por flutuações no laser e no potencial da armadilha, ocasionando flutuações na freqiiência de Rabi, levando a uma perda de coerência no modo principal do íon sem relaxação de energia e de acordo com os resultados experimentais. Ainda com íons, apresentamos um novo método para tratar a dinâmica deste sem recorrermos ao limite de Lamb-Dicke. O método é ba.."eado em uma transformação unitária que leva a Hamiltoniana do sistema em uma Hamiltoniana tipo Jaynes-Cummings (JCM). Focalizamos a nossa atenção na dinâmica atômica e na dinâmica do número médio de excitações do íon. A dinâmica obtida é diferente da dinâmica de quando o sistema é tratado na forma tradicional, ou seja usando o limite de Lamb-Dicke (LDL). Nessa nova dinâmica o sistema se comporta similarmente ao modelo Jaynes-Cumings forçado (DJCM) e com uma escolha apropriada dos parametro do íon efeitos de 'super-revival' são observados. Além do comportamento dinâmico dada acima, a transfomação tem sido utilizada como proposta de implementação de portas quânticas rápidas com velocidade que pode chegar a duas ordem de grandeza maior do que as obtidas por outros métodos. Uma outra aplicação importante tem sido a utilização da transformação para a geração de 'gatos de Schrõdinger' / Abstract: In this thesis we studied the dynamics of two quantum systems: atoms in a cavity and trapped ions. For atoms in a cavity ( QED ) , we studied the dynamics of field prepared in a superposition of coherent states and a statistical mixture. In this system, using a Intensity-Dependence Jaynes-Cummings model (DNJCM) we discuss some aspects of the dynamics of atom-field in the Jaynes-Cummings model (JCM) interaction, and showed that for a field prepared in a even-coherent state ( even Schrõdinger cat) it becomes an odd-coherent state ( odd Schrõdinger cat) at the first revival time, and at the same time the atom initially prepared in the excited state becomes the ground state. This behavior is due not only for energy conservation reason, but also for parity conservation in the atomfield system. We have found that, in DNJCM, a field initially prepared in a statistical mixture evolves toward apure state. This is a consequence of the intrinsic periodicity of the model. We may ask why this behavior has not been noticed by considering the field evolution in the ordinary JCM. In the trapped ion system, we studied the generation of nonclassical state of motion of a single ion. To explain the decoherence we introduced a phenomenological model that consider mode cross-coupling. This coupling can be due to technical problems: intensity fluctuation of the laser beams and instabilities of the trap leading to decoherence of the principal mode. Still studying ions, we show a new approach to discuss the dynamics of the ion without the Lamb-Dicke Limit (LDL). In this approach we depart from the full ion laser Hamiltonian, and perform a unitary transformation that allows us to obtain a JCM like Hamiltonian. The dynamics obtained is different from the dynamics when the system is treated in the traditional form, in the LDL. In the new dynamics the system is similar to the Driven-Jaynes-Cummings model (DJCM), and we expect the phenomenon of super-revival to be present in the ion system. Besides the dynamics present here, the transformation has been used in a scheme for generation of a quantum gate and Schrodinger cats / Doutorado / Física / Doutor em Ciências
32

Influencia de irrigantes endodonticos na resistencia de união de um adesivo autocondicionante a dentina da camara pulpar

Santos, Juliana Nascimento 04 August 2005 (has links)
Orientador: Caio Cezar Randi Ferraz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:48:38Z (GMT). No. of bitstreams: 1 Santos_JulianaNascimento_M.pdf: 2388300 bytes, checksum: a85a059075e841f9cf9e63475002101f (MD5) Previous issue date: 2005 / Resumo: A utilização de soluções irrigadoras e medicações durante o tratamento endodôntico pode ter um efeito deletério sobre a adesão às estruturas dentinárias da cavidade pulpar. Este estudo teve como objetivo avaliar in vitro a influência dos irrigantes endodônticos na resistência de união de um sistema adesivo autocondicionante à dentina da câmara pulpar de dentes bovinos. Setenta coroas de incisivos inferiores bovinos foram seccionadas expondo a câmara pulpar. O tecido pulpar foi removido e a embocadura do canal radicular selada com material restaurador provisório. Os espécimes foram divididos aleatoriamente em 7 grupos experimentais, de acordo com o irrigante utilizado: G1- NaCl 0,9%, G2- NaOCl 5,25%, G3- NaOCl 5,25% seguido por EDTA 17%, G4- sol. de gluconato de clorexidina 2%, G5- sol. de gluconato de clorexidina 2% seguida por EDTA 17%, G6- gluconato de clorexidina gel 2%, G7- gluconato de clorexidina gel 2% seguido por EDTA 17%. Cada solução permaneceu 30 min. em contato com as paredes da câmara pulpar com exceção do EDTA, que atuou por 5 min. Após o tratamento com os irrigantes, procedeu-se à lavagem com água destilada, secagem e aplicação do adesivo Clearfil SE Bond (Kuraray) seguido do compósito Filtek Z250 (3M), que foi inserido em incrementos. Após 24h de armazenamento em água a 37oC os espécimes foram submetidos ao teste de microtração, que verificou a resistência de união na interface resina-dentina. Os resultados obtidos em MPa (G1: 37,25 ± 2,07a; G2: 26,40 ± 2,07c; G3: 20,37 ± 1,46c; G4: 35,75 ± 1,85ab; G5: 34,79 ± 2,16ab; G6: 36,20 ± 1,53ab; G7: 33,09 ± 1,53b) foram analisados pelo teste de log-rank e observou-se diferença estatisticamente significativa (p<0,05) entre os grupos que utilizaram NaOCl (G2 e G3) e os demais. Além disso,o grupo que utilizou clorexidina gel 2% associada ao EDTA 17% (G7) apresentou diferença estatisticamente significativa em relação ao grupo do NaCl (G1). Concluiu-se então que, nas condições deste estudo, a resistência de união do sistema adesivo Clearfil SE Bond à dentina da câmara pulpar foi diminuída pela irrigação endodôntica com NaOCl 5,25% associado ou não ao EDTA / Abstract: Chemical irrigants and medications used in endodontic therapy may have an adverse effect on bonding to pulp chamber dentin. The aim of this study was to evaluate in vitro the influence of endodontic irrigants on the bond strength of a self etching adhesive system to bovine teeth pulp chamber dentin. Seventy crowns of bovine mandibular incisors were cut to expose the pulp chamber. The pulp was extirpated and the root canal orifice sealed with temporary restorative material. The specimens were divided into seven experimental groups, according to the solution used: G1- 0,9% NaCl, G2- 5,25% NaOCl, G3- 5,25% NaOCl and 17% EDTA, G4- 2% chlorhexidine gluconate solution, G5- 2% chlorhexidine gluconate solution and 17% EDTA, G6- 2% chlorhexidine gluconate in a gel base, G7- 2% chlorhexidine gluconate in a gel base and 17% EDTA. Each irrigant solution remained 30 minutes in contact with pulp chamber dentin, except for EDTA, which remained for 5 minutes. After irrigation, teeth were washed with distilled water and dried. A self etching adhesive system, Clearfil SE Bond (Kuraray), was applied according to manufacturer¿s instructions, followed by Filtek Z250 resin composite, which was applied in incremental layers. After 24h storage in 37°C distilled water, the microtensile bond test was performed. Bond strength values obtained in MPa (G1: 37,25 ± 2,07a; G2: 26,40 ± 2,07c; G3: 20,37 ± 1,46c; G4: 35,75 ± 1,85ab; G5: 34,79 ± 2,16ab; G6: 36,20 ± 1,53ab; G7: 33,09 ± 1,53b) were analyzed by the log-rank test (survival analysis) and statistical significant differences (p<0.05) were found between sodium hypochlorite groups (G2 and G3) and the other groups. Bond strength values of chlorhexidine gel and EDTA group (G7) were also statistically different from NaCl (control) group (G1). It could be concluded that, in the conditions of this experiment, bond strength of Clearfil SE Bond to pulp chamber dentin decreased when endodontic irrigation with 5,25% NaOCl associated or not to 17% EDTA was performed. / Mestrado / Endodontia / Mestre em Clínica Odontológica
33

[en] DETERMINATION OF THE INPUT IMPEDANCE OF AN ANTENNA IN AN OPEN RECTANGULAR CAVITY / [pt] DETERMINAÇÃO DA IMPEDÂNCIA DE ENTRADA DE UMA ANTENA INTERIOR DE UMA CAVIDADE RETANGULAR ABERTA

RAIMUNDO JOSE DOS SANTOS MOTA 20 October 2009 (has links)
[pt] O propósito deste trabalho é apresentar formulação para a determinação da impedância de entrada de uma antena colocada no interior de uma cavidade retangular com um dos lados aberto. O procedimento utilizado consiste na determinação da potência total irradiada da qual se obtém a impedância de entrada. A colocação do problema é feito utilizando o método do casamento de modos (Mode Match). Apresentam-se algumas considerações com relação ao erro surgido com as truncagens dos modos de índices elevados, aproximações da utilização em verificação experimental e aplicações. / [en] This work presents a formulation for determining the input impedance for an antenna located inside fo a rectangular cavity having one side open. The current distribution on the antena and the total power radiater are determined using and apropriate Green’s function and anatytic procedure from which the impedance is calculated. The problem is approchea and solved using the method of Mode Matching. Some considerations concerning the erros due to the truncation of modes of larges index used in the aproximation method are presented as well as practical consideration for experimentally verifing and applying the results.
34

Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica / Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation

Silva, Ricardo Virgolino Carvalho da 16 April 2010 (has links)
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários / The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
35

Concepção de um receptor de cavidade para concentração de energia solar para aplicação em reatores químicos. / Cavity receiver conception for solar concentrating chemical reators.

Nigro, Luciano Giannecchini 08 May 2015 (has links)
Este trabalho dimensionou um receptor de cavidade para uso como reator químico de um ciclo de conversão de energia solar para energia química. O vetor energético proposto é o hidrogênio. Isso implica que a energia solar é concentrada em um dispositivo que absorve a radiação térmica e a transforma em energia térmica para ativar uma reação química endotérmica. Essa reação transforma o calor útil em gás hidrogênio, que por sua vez pode ser utilizado posteriormente para geração de outras formas de energia. O primeiro passo foi levantar os pares metal/óxido estudados na literatura, cuja finalidade é ativar um ciclo termoquímico que possibilite produção de hidrogênio. Esses pares foram comparados com base em quatro parâmetros, cuja importância determina o dimensionamento de um receptor de cavidade. São eles: temperatura da reação; estado físico de reagentes e produtos; desgaste do material em ciclos; taxa de reação de hidrólise e outros aspectos. O par escolhido com a melhor avaliação no conjunto dos parâmetros foi o tungstênio e o trióxido de tungstênio (W/WO3). Com base na literatura, foi determinado um reator padrão, cujas características foram analisadas e suas consequências no funcionamento do receptor de cavidade. Com essa análise, determinaram-se os principais parâmetros de projeto, ou seja, a abertura da cavidade, a transmissividade da janela, e as dimensões da cavidade. Com base nos resultados anteriores, estabeleceu-se um modelo de dimensionamento do sistema de conversão de energia solar em energia útil para um processo químico. Ao se analisar um perfil de concentração de energia solar, calculou-se as eficiências de absorção e de perdas do receptor, em função da área de abertura de um campo de coleta de energia solar e da radiação solar disponível. Esse método pode ser empregado em conjunto com metodologias consagradas e dados de previsão de disponibilidade solar para estudos de concentradores de sistemas de produção de hidrogênio a partir de ciclos termoquímicos. / This work aimed to design a cavity receptor for purpose of chemical reactor for cycles of energy conversion of solar energy to chemical energy. The proposed chemical agent is hydrogen gas. Solar energy is concentrated in a device that absorbs thermal radiation, transforming it in thermal energy, used to activate chemical reactions. This reaction transforms the heat in hydrogen gas and the last, in its turn, can be used to generate other forms of energy. The first step oh this work was an assessment of metal/oxides pairs studied in literature, which can be used to activate thermochemical cycles for hydrogen production. These pairs were compared based in four parameters, important to cavity receptor design: reaction temperature, physical state of the reactants and products, material resistance to several cycles; hydrolysis reaction rate and other aspects. The chosen pair, rated as the higher average in all parameters, was the pair tungsten and tungsten trioxide. (W/WO3). Based in the literature, it was determined a standard reactor, which was studied regarding cavity reactor performance. By such analysis, it was possible to determine the main design parameters, therefore, cavity aperture, window transmissivity, and the cavity geometric dimensions. The results allowed to establish a mathematical model in which solar energy can be converted in useful energy for chemical processes, inside a cavity receptor. Given a profile of solar energy concentration, it was calculated absorption and energy lost efficiencies, related to a solar concentration field and radiation available. This method can be used in tandem with available methodologies and data of solar predictions for hydrogen production by concentration systems via thermochemical cycles.
36

Avaliação "in vitro" da microinfiltração marginal em cavidades de Classe V, restauradas com resinas compostas condensáveis, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina

Nunes, Osvaldo Benoni da Cunha 09 November 2001 (has links)
A finalidade deste trabalho foi verificar o grau de infiltração marginal em cavidades classe V, vestibulares e linguais, em dentes pré-molares humanos extraídos por razões ortodônticas e restaurados com resina composta condensável, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina. Foram utilizados 50 dentes livres de cáries, que após a coleta foram limpos e fixados em formalina tamponada a 10% e, a seguir, armazenados em água destilada. Foram realizadas cavidades classe V por vestibular e lingual com 3 mm de diâmetro e 1,5 mm de profundidade, e em seguida restaurados e agrupados segundo o material restaurador escolhido em : Grupo I: dentes restaurados com resina composta condensável Alert; Grupo II: dentes restaurados com resina composta condensável Solitaire; Grupo III: dentes restaurados com resina composta híbrida Z- 250 ; Grupo IV: dentes restaurados com compômero Dyract AP e Grupo V: dentes restaurados com ionômero de vidro Vitremer (grupo controle). Concluídas as restaurações os dentes foram imersos em água destilada a 37ºC por 24 horas; polidos com discos Sof-Lex e impermeabilizados com Araldite e esmalte para unhas, preservando-se 2 mm ao redor da restauração, sem impermeabilização. Uma vez secos, os dentes foram submetidos à ciclagem térmica com temperatura de 5ºC/ 55 º C, em um total de 200 ciclos, com 30 segundos em cada banho. Os dentes foram imersos em uma solução aquosa de azul de metileno a 2% por um período de 24 horas. Concluídos os procedimentos acima, os espécimes foram lavados e cortados longitudinalmente com disco diamantado, no sentido vestíbulo-lingual. Os dentes foram examinados com lupa com aumento de 7x e classificados segundo o grau de penetração máxima do corante, utilizando-se escores de 0 a 4, segundo o número de paredes infiltradas. A análise estatística aplicada aos resultados obtidos permitiu as seguintes conclusões: a resina composta Alert demonstrou menor infiltração marginal (P<0,05), seguida do Dyract AP, sendo que ambas comportaram-se estatisticamente melhor que os demais grupos. Não houve diferença estatística significante entre a resina Z-250 e o Vitremer. A resina composta Solitaire teve o pior desempenho quanto à infiltração marginal. / This study compares the marginal leakage of four restorative materials: condensable resin composites (Group I: Alert and Group II: Solitaire), hybrid resin composite (Group III: Z-250) and polyacid-modified resin composite (Group IV: Dyract). Vitremer (Group V), resin- modified glass ionomer was chosen as the control group. Fifty sound pre-molars extracted for orthodontic reasons were cleaned, fixed in 10% formalin and stored in destiled water. Class V restorations (diameter= 3mm, depth= 1,5mm) were prepared in the vestibular and lingual surfaces. Following restorations placement (N=100), the samples were immersed in destiled water for 24 hours at 37º C and polished with Sof-Lex discs. The samples were made impermeable (varnish) excluding 2 mm area around the restoration. The teeth were dried and submitted to 200 termic cicles (5ºC/55ºC) each one lasting 30 seconds. The samples were immersed in 2% methylene blue dye for 24 hours and sliced longitudinally (vestibular to lingual surfaces) with diamond disc. A 7-fold magnifying glass was used to classify the samples (0-4 score) according to maximum dye penetration level and number of infiltration sites . The difference was significant (P<0,05) for Group I: Alert and Group IV: Dyract. The other three groups showed non statistically significant results with the poorest performance by Solitaire.
37

Espectroscopia de cavidade ressonante tipo Ring-DOWN supercontinuum resolvida no tempo para detecção de multicomponentes gasosos / Supercontinuum Cavity Ring-Down Spectroscopy For Simultaneous Detection Of Multicomponent Gases

Walter Morinobu Nakaema 21 October 2010 (has links)
Neste trabalho, é apresentada uma variação da técnica de espectroscopia por cavidade ressonante tipo ring-down CRDS (do acrônimo em inglês Cavity Ring-Down Spectroscopy) para a obtenção simultânea do espectro de absorção de multicomponentes numa faixa espectral larga do visível. Esta nova técnica se resume no uso do espectro supercontinuum (resultante da irradiação de meios não lineares através de lasers de femtossegundo, ou simplesmente gerada por fontes compactas) como fonte de luz para iluminar a cavidade. Neste contexto são descritas as características dos módulos para a montagem de um MC-SC-CRDS (Multicomponent Supercontinuum Cavity Ring-Down Spectroscopy): os pares de espelhos altamente refletivos, a cavidade ressonante e o sistema de detecção. Alguns problemas relacionados à excitação de multimodos, à luz difusa, ao uso efetivo do intervalo dinâmico de detecção, à baixa resolução do instrumento em resolver linhas estreitas de absorção são situados. Apresentamos os espectros de absorção de H2O (políades 4nu, 4nu + delta ) e O2 (transições proibidas de spin b-X) simultaneamente medidos por essa técnica na faixa do visível, e uma comparação com as linhas de absorção baseadas do banco de dados HITRAN é feita para demonstrar a funcionalidade deste método. / In this work, we present a variation of the technique CRDS (Cavity Ring-Down Spectroscopy) to obtain simultaneously a multicomponent absorption spectrum in a broad visible range. This new approach uses the Supercontinuum (SC) spectrum (resulting from irradiation of nonlinear media by femtosecond lasers, or simply generated by compact sources) as a light source to illuminate the cavity. In this context it is described the features of the modules assembling a MC-SC-CRDS (Multicomponent Supercontinuum Cavity Ring-Down Spectroscopy): a set of high refletivity mirrors, the resonant cavity and the detection system. Some problems related to the multimode excitation, stray light, effective use of the dynamic range of the detector, the poor resolution of the instrument to resolve narrow absorption lines are issued. We present the absorption spectra of H2O (polyads 4nu, 4nu + delta ) and O2 (spin-forbidden b-X branch) measured simultaneously by this technique in the visible range and a comparison with the absorption lines based on HITRAN database is made to demonstrate the functionality of this method.
38

Espectroscopia de cavidade ressonante tipo Ring-DOWN supercontinuum resolvida no tempo para detecção de multicomponentes gasosos / Supercontinuum Cavity Ring-Down Spectroscopy For Simultaneous Detection Of Multicomponent Gases

Nakaema, Walter Morinobu 21 October 2010 (has links)
Neste trabalho, é apresentada uma variação da técnica de espectroscopia por cavidade ressonante tipo ring-down CRDS (do acrônimo em inglês Cavity Ring-Down Spectroscopy) para a obtenção simultânea do espectro de absorção de multicomponentes numa faixa espectral larga do visível. Esta nova técnica se resume no uso do espectro supercontinuum (resultante da irradiação de meios não lineares através de lasers de femtossegundo, ou simplesmente gerada por fontes compactas) como fonte de luz para iluminar a cavidade. Neste contexto são descritas as características dos módulos para a montagem de um MC-SC-CRDS (Multicomponent Supercontinuum Cavity Ring-Down Spectroscopy): os pares de espelhos altamente refletivos, a cavidade ressonante e o sistema de detecção. Alguns problemas relacionados à excitação de multimodos, à luz difusa, ao uso efetivo do intervalo dinâmico de detecção, à baixa resolução do instrumento em resolver linhas estreitas de absorção são situados. Apresentamos os espectros de absorção de H2O (políades 4nu, 4nu + delta ) e O2 (transições proibidas de spin b-X) simultaneamente medidos por essa técnica na faixa do visível, e uma comparação com as linhas de absorção baseadas do banco de dados HITRAN é feita para demonstrar a funcionalidade deste método. / In this work, we present a variation of the technique CRDS (Cavity Ring-Down Spectroscopy) to obtain simultaneously a multicomponent absorption spectrum in a broad visible range. This new approach uses the Supercontinuum (SC) spectrum (resulting from irradiation of nonlinear media by femtosecond lasers, or simply generated by compact sources) as a light source to illuminate the cavity. In this context it is described the features of the modules assembling a MC-SC-CRDS (Multicomponent Supercontinuum Cavity Ring-Down Spectroscopy): a set of high refletivity mirrors, the resonant cavity and the detection system. Some problems related to the multimode excitation, stray light, effective use of the dynamic range of the detector, the poor resolution of the instrument to resolve narrow absorption lines are issued. We present the absorption spectra of H2O (polyads 4nu, 4nu + delta ) and O2 (spin-forbidden b-X branch) measured simultaneously by this technique in the visible range and a comparison with the absorption lines based on HITRAN database is made to demonstrate the functionality of this method.
39

Novas tecnologias x instrumento rotatório convencional: avaliação das variáveis que podem interferir no estado emocional da criança

Josgrilberg, Érika Botelho [UNESP] 17 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-17Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 josgrilberg_e_dr_arafo.pdf: 1774679 bytes, checksum: ae031b6add35dd8be0e61381e81747cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi identificar os estados emocionais indicativos de medo/ansiedade da criança com (CE) ou sem experiência odontológica prévia (SE) frente à utilização de três diferentes formas de realização de preparos cavitários: ultra-som (Sistema CVDentus®), sistema de abrasão a ar (Rondoflex®) e alta rotação (Kavo). Quarenta e oito crianças de 7-11 anos de idade foram divididas aleatoriamente em 2 grupos (CE e SE). O tratamento odontológico compreendeu o preparo cavitário de lesões de cárie oclusal nos dentes 16 e 26, realizados em duas sessões, utilizando Alta Rotação e o Abrasão a ar ou Ultra-som. Durante a consulta a freqüência cardíaca da criança foi aferida nas seguintes situações: sala de espera, ao sentar na cadeira, anestesia, isolamento absoluto, cinco minutos após o início do tratamento e ao final da consulta. Além disso, foi aplicada a escala “Facial Image to assess child dental anxiety - FIS”, antes e após cada atendimento. Para a avaliação do medo da criança foi utilizado o teste “Children Fear Survey Schedule- Dental Subscale (CFSSDS)”. Para a avaliação do comportamento infantil foi utilizada a escala de Frankl. Os resultados obtidos do Teste de Friedman para freqüência cardíaca e para a escala “FIS” não apontaram diferença estatística entre os grupos CE e SE e entre as três tecnologias utilizadas. Entretanto, houve aumento nos batimentos cardíacos ao sentar na cadeira odontológica (p < 0,05). Os resultados obtidos pelo teste CFSS-DS apontou uma amostra homogênea com baixos níveis de medo/ansiedade odontológica. Nenhuma criança apresentou comportamento definitivamente negativo ou negativo. Conclui-se o medo/ansiedade da criança aumenta quando ela senta na cadeira odontológica, porém tende a diminuir no decorrer do tratamento independente da tecnologia utilizada para o preparo cavitário. / The aim of this study was to identify fear/anxiety in children with past dental experience (CE) or not (SE) using three different manner of dental cavity preparation: ultrasound (Sistema CVDentus®), air abrasion system (Rondoflex®) and rotatory instrument (Kavo). Forty eight children, with 8- 12 years old were randomly divided into 2 groups (CE e SE). Dental treatment was realized in two sessions, including dental cavity preparation of occlusal caries on 16 e 26 tooth, using Rotatory Instrument and o Air Abrasion System or Ultrasound. During dental procedures children heart rate was taken, on following situations: waiting room, seating on dental chair, anesthesia, when using rubber dam, 5 minutes after the treatment beginning and on final session. Additionally, a “Facial Image to assess child dental anxiety” (FIS) was uses before and after treatment. To evaluate children dental fear was used the questionnaire “Children Fear Survey Schedule- Dental Subscale (CFSS- DS)”. The comparison of the two groups (CE and SE) and the three technologies use for dental cavity preparation in heart rate study and FIS, submitted to Friedman’s test resulted on no significant difference. However, it was observed higher heart rate when children seats on dental chair (p < 0.05). CFSS-DS results demonstrate a homogeneous sample with lower dental fear/anxiety. It was concluded that children anxiety and fear are higher on sitting on dental chair and tend to diminish during technological devices free treatment.
40

Análise do perfil metabólico e epidemiológico de portadores de carcinoma epidermoide de cavidade oral / Analysis of the metabolic and epidemiological profile of patients with squamous cell carcinoma of the oral cavity

Smarra, Luis Fabiano Soares 11 May 2018 (has links)
O carcinoma epidermoide de cavidade oral (CECO) é um dos tumores mais comuns em câncer de cabeça e pescoço, com aproximadamente 300.000 novos casos e 145.000 mortes em todo o mundo. Apesar da intensa pesquisa e dos avanços recentes no diagnóstico e terapia, a taxa de sobrevivência dos pacientes ainda é baixa. Os estudos da metabolômica levaram a uma melhor compreensão do metabolismo do câncer, no seu desenvolvimento e progressão. Essas descobertas possibilitaram a identificação de biomarcadores metabólicos que podem auxiliar na identificação de doenças e tratamentos. O presente estudo buscou três objetivos: (1) Identificar e quantificar os metabólitos plasmáticos em portadores de CECO e em controles, utilizando técnicas de ressonância magnética nuclear (RMN); (2) Comparar a concentração plasmática de metabólitos de pacientes com CECO com a de seus controles estratificados por variáveis clínicas, patológicas, sociodemográficas e características de estilo de vida; (3) Avaliar se as concentrações de metabólitos estão relacionadas com a presença da doença (CECO), ajustadas pelas variáveis epidemiológicas e características de estilo de vida. Para a análise dos metabólitos, amostras de plasma sanguíneo de 47 casos e de 49 controles foram identificadas, quantificadas e comparadas com variáveis clínicas, patológicas, sociodemográficas e características de estilo de vida por meio de análises estatísticas. Os resultados mostram que todos os indivíduos portadores de CECO estiveram expostos em algum momento da vida aos fatores de risco (álcool, tabaco e má higiene bucal). Além disso, as variáveis mostraram interferir na concentração dos metabólitos, estes que apresentaram-se alterados, principalmente os que possuem relação com as vias metabólicas de obtenção de energia, sugerindo que o metabolismo de pacientes com CECO difere dos indivíduos sem a doença (controles) / Squamous cell carcinoma of the oral cavity (SCCOC) is one of the most common tumors in head and neck cancer, with approximately 300,000 new cases and 145,000 deaths worldwide each year. Despite intense research and recent advances in diagnosis and therapy, the patient\'s survival rate is still low. Metabolism studies have led to a better understanding of the metabolism of cancer in its development and progression. Theses findings allowed the identification of metabolic biomarkers that may aid to identificate diseases and treatments. This current study aimed at three objectives: (1) To identify and quantify plasma metabolites in SCCOC patients and controls using nuclear magnetic resonance (NMR) techniques; (2) To compare plasma concentration of metabolites of patients with SCCOC and its stratified controls by clinical, pathological, sociodemographics, and lifestyle characteristics; (3) To evaluate whether the metabolic concentrations are related to the presence of SCCOC, adjusted by epidemiological variables and lifestyle characteristics. In order to analyze the metabolites, blood plasma samples from 47 cases and 49 controls were identified, quantified and compared with clinical, pathological, sociodemographic, and lifestyle variables by means of statistical analysis. The results show that all subjects with SCCOC were exposed eventually to risk factors (alcohol consumption, smoking and bad oral hygiene). Furthermore, the variables showed to interfere in the concentration of metabolites, which have been altered, especially those that are related to metabolic pathways of obtaining energy, suggesting that the metabolism of patients with SCCOC differs from the individuals without the disease (controls)

Page generated in 0.081 seconds