• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 246
  • 9
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 1
  • 1
  • Tagged with
  • 266
  • 161
  • 65
  • 63
  • 55
  • 41
  • 38
  • 36
  • 32
  • 25
  • 23
  • 23
  • 22
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Comparação termométrica entre preparos cavitários realizados com turbinas de alta-rotação e laser de Er:YAG /

Cavalcanti, Bruno das Neves. January 2001 (has links)
Orientador: Sigmar de Mello Rode / Banca: Fernando Ricardo Xavier da Silveira / Banca: Maria Auxiliadora Junho de Araujo / Resumo: O objetivo deste estudo foi comparar as variações de temperatura provocadas por turbinas de alta-rotação e pelo laser de Er:YAG (350mJ/10 Hz). Preparos cavitários classe V foram realizados numa profundidade de 2,0mm em 35 incisivos inferiores bovinos, que tiveram um termopar posicionado para ler as temperaturas no interior da câmara pulpar. A análise foi feita nos seguintes grupos: I - alta-rotação sem refrigeração a água; II - alta-rotação com refrigeração a água; III- laser de Er:YAG sem refrigeração a água; IV- laser de Er:YAG com refrigeração a água. Em todos os grupos foram utilizados dez dentes, com exceção do grupo III, que teve uma amostra de apenas cinco dentes, uma vez que foi impossível realizar os preparos adequadamente com o laser sem refrigeração. Os aumentos de temperatura foram gravados num computador ligados aos termopares e os dados dos grupos I, lI e IV foram submetidos ao teste de Dunn para comparações múltiplas (p<0,05). Os aumentos médios de temperatura foram: 11,64°C para o grupo I, 0,96°C para o grupo II, 40,86°C para o grupo lll e 2,9°C para o grupo IV. Não houve diferenças estatisticamente significantes entre os grupos II e IV, e estes foram diferentes do grupo I. Os preparos cavitários realizados com as turbinas de alta-rotação e com o laser de Er:YAG geraram aumentos de temperatura semelhantes quando sob refrigeração a água. A refrigeração é essencial para evitar aumentos de temperatura agressivos em ambos os casos e com o laser de Er:YAG é especialmente necessária para a ablação do esmalte / Abstract: The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel / Mestre
42

Hábitos de higiene e saúde bucal em relação à infecção por HPV oral em policiais militares de um quartel da cidade de Salvador./ [Manuscrito]. Ramsés de Freitas Ventura.

Ventura, Ramsés deFreitas 21 December 2016 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2017-05-19T23:47:54Z No. of bitstreams: 1 Ramsés Freitas Ventura.pdf: 2270430 bytes, checksum: c7916be4017e09c0709522c10f2a5c92 (MD5) / Made available in DSpace on 2017-05-19T23:47:54Z (GMT). No. of bitstreams: 1 Ramsés Freitas Ventura.pdf: 2270430 bytes, checksum: c7916be4017e09c0709522c10f2a5c92 (MD5) / O HPV é um vírus de mucosa, com disseminação em todo mundo e uma considerável prevalência relatada por alguns estudos, em face de sua capacidade de transmissão. Mais de 100 tipos desse vírus já foram isolados e caracterizados, sendo que cerca de ¼ deles estão relacionados com ocorrências de lesões benignas e malignas de cabeça e pescoço. Pesquisas realizadas com militares das Forças Armadas demonstram uma população suscetível ao contágio por DST, por apresentarem diversos comportamentos de risco. Pelo fato de passarem muito tempo longe das suas companheiras, não é incomum que procurem relacionamentos extraconjugais passageiros e até mesmo profissionais do sexo. A convivência em ambientes fechados e o compartilhamento de objetos de uso pessoal também foram analisados como possíveis meios de transmissão, no entanto, estudos dessa natureza, com policiais militares, ainda são escassos no Brasil. A população da amostra foi composta por policiais militares atendidos nos serviços odontológicos da Polícia Militar da Bahia, onde eles relataram consideráveis comportamentos consagrados como de risco, embora tenham sido avaliados com boas condições de saúde e de higiene bucal. Os exames para detecção do papilomavírus humano nos tecidos bucais, apesar da comprovada eficácia dos primers utilizados e da integridade dos materiais genéticos das células analisadas, foram negativos para todos os voluntários e também não foram encontradas lesões compatíveis ou sugestivas de produção por HPV. Diante do exposto, este estudo sugere que os hábitos de higiene bucal, como controle físico e químico do biofilme, bem como a frequência de comparecimento aos consultórios odontológicos, podem contribuir para a prevenção ao contágio ou ao desenvolvimento da patogenia do vírus, sendo necessários novos estudos para aprofundamento e confirmação da conclusão proposta
43

Influência do desenho da cavidade na microinfiltração marginal de restaurações cerâmicas tipo MOD

Kina, Mônica January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T12:01:34Z (GMT). No. of bitstreams: 1 234066.pdf: 1169220 bytes, checksum: 7b61e6d5f84afb7e5b54cc521b7f24e2 (MD5) / O objetivo deste estudo foi avaliar a influência do desenho da cavidade na infiltração marginal de inlays cerâmicos.Foram confeccionados 30 cavidades classe II (MOD) em pré-molares, com término gengival mesial em esmalte e distal em dentina, obtendo-se as seguintes características: Grupo I: cavidades com divergência de 12º; Grupo II:cavidades com divergência de 18º; Grupo III:cavidades com divergência de 24º.Os inlays cerâmicos de IPS-Empress foram cimentados de acordo com as instruções do fabricante e submetidos ao teste de termociclagem. Após os testes estatísticos, concluiu-se que as divergências das paredes das cavidades, bem como a localização das margens (esmalte ou dentina) influenciam a microinfiltração de inlays cerâmicos confeccionados como sistema IPS-Empress. This in vitro study evaluates the influence of the cavity design on the microleakage of IPSEmpress ceramic inlays. Thirty extracted human bicuspids were selected and stored at room temperature. The specimens were randomly ascribed to three groups (n=10). Class II (MOD) cavities with gingival margins in enamel and dentin were prepared: Group I # 12° divergent walls; Group II - 18° divergent walls; Group III - 24° divergent walls. After the impressiontaking, IPS Empress® inlays (Ivoclar Vivadent) were fabricated according with the manufacturer#s instructions. The teeth were thermocycled (500 cycles, 5° to 55°C), sealed with nail varnish, immersed in a 0.5% basic fuchsin solution for 24 hours, embedded in epoxy resin, and cut in a mesio-distal direction. The sections were evaluated using a linear quantitative method (in mm) by three previously calibrated evaluators which used a software (ImageTool, San Antonio, TX, EUA). The results were statistically analyzed using one-way ANOVA and paired T-test. It was concluded that the walls divergence did not influence the degree of microleakage. Group I presented the highest microleakage values (p=0.0001), and Groups II and III did not present statistically significant differences (p=0.0022). Regarding the location of the gingival margin (enamel or dentin), the highest values were observed for dentin margins (p<0.0001). None of the groups was capable to reduce completely the marginal leakage.
44

Abordagem clínico-cirúrgica ventral à cavidade pélvica de cadelas / Ventral clinical-surgical approach to pelvic cavity in bitches

Filgueiras, Richard da Rocha 05 April 2002 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-06-08T11:09:36Z No. of bitstreams: 1 texto completo.pdf: 2808265 bytes, checksum: fd950636d21c5e860df278dea0f2a11f (MD5) / Made available in DSpace on 2017-06-08T11:09:36Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2808265 bytes, checksum: fd950636d21c5e860df278dea0f2a11f (MD5) Previous issue date: 2002-04-05 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objetivando avaliar a abordagem cirúrgica da cavidade pélvica após osteotomia isquiopúbica bilateral, a facilidade de exposição e manipulação dos órgãos pélvicos e a reparação com osso autógeno, foram operadas sete cadelas, sem raça definida, clinicamente sadias com peso entre 10 e 20 kg, e realizados exames clínicos diários e radiográficos, macro e microscópicos pós-morte, aos 15, 45, 60 e 75 dias após as cirurgias. A osteotomia isquiopúbica bilateral permitiu boa exposição e manipulação dos órgãos intrapélvicos, excetuando-se a porção dorsal do reto. O desconforto pós- operatório foi considerado mínimo em 100% dos animais. O retorno à deambulação normal ocorreu, em média, 24 horas após a cirurgia, o apetite e a micção foram restabelecidos em 24 horas e a defecação sem desconforto foi restabelecida, em média, 48 horas depois. Foi observada ligeira mobilidade da região de osteossíntese, após palpação pós-morte, independente da presença ou ausência de tecido conjuntivo fibroso envolvendo a peça óssea autógena e a pelve hospedeira, em todos os períodos de observação. Radiograficamente, 100% dos animais apresentaram união incompleta até o final do experimento e nas avaliações feitas aos 60 e 75 dias observou-se perda da densidade da peça óssea usada na reconstituição da pelve. Microscopicamente, houve deposição local de grande quantidade de tecido conjuntivo fibroso, crescimento endocondral a partir da pelve hospedeira e áreas de reabsorção foram notadas tanto na peça óssea quanto na pelve hospedeira. O acesso ventral à cavidade pélvica após osteotomia isquiopúbica bilateral providenciou ampla exposição do trato urogenital e do reto excetuando-se sua porção dorsal, permitindo intervenções cirúrgicas intrapélvicas com mínimo desconforto pós–operatório. / In order to evaluate the surgical approach of the pelvic cavity after bilateral pubic and ischial osteotomy, the facility of exposition and manipulation of the pelvic organs and the repair with autogenous bone, 7 adult clinically healthy mongrel female dogs weighing between 10 and 20 kg were operated and submitted to daily clinical evaluations. They were also submitted to radiographic and macro and microscopic post mortem exams at the 15, 45, 60 and 75 days from postoperative. The bilateral pubic and ischial osteotomy allowed good exposure and manipulation of intrapelvic organs except for the dorsal portion of the rectum, being the postoperative discomfort considered minimum in 100% of the animals. The return to the normal deambulation happened in average 24 hours after the surgery. The appetite and urination were reestablished in 24 hours and the defecation without discomfort in 48 hours of postoperative. After post mortem palpation it was observed slight mobility of the osteossintesis area, independent of the presence or absence of fibrous conjunctive tissue involving the autogenous bone piece and the host pelvis, in all the observation periods. The radiographic evaluations showed that 100% of the animals presented incomplete union until the end of the experiment. It was also observed loss of density of the bone piece used in the reconstruction of the pelvis on the 60 th and 75 th days. Microscopically there was local deposition of great amount of fibrous conjunctive tissue and endochondral growth from the host pelvis and reabsorption were noticed in the bone piece and in the host pelvis. The ventral access to the pelvic cavity after the bilateral ischiopubic osteotomy provided ample exposition of the urogenital tract and of the rectum, except for its dorsal portion, allowing intrapelvic surgical interventions with a minimum of post-operative discomfort.
45

Efeito da expansão rápida da maxila assistida cirurgicamente na dimensão nasal / Effect of surgically-assisted rapid maxillary expansion on nasal dimension

Mitsuda, Sergio Takeji [UNIFESP] January 2008 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:47:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2008 / INTRODUÇÃO: A expansão rápida da maxila assistida cirurgicamente (ERMAC) é o tratamento de escolha para correção da deficiência transversal da maxila superior a cinco milímetros, em pacientes com maturidade esquelética, podendo extrapolar seus efeitos do arco maxilar para a cavidade nasal. OBJETIVO: Avaliar o efeito da expansão rápida da maxila assistida cirurgicamente (ERMAC) na dimensão nasal, utilizando rinometria acústica. MÉTODOS: Foram avaliados 27 pacientes, com idade entre 18 a 53 anos, com deficiência transversal da maxila maior que cinco milímetros (mm), mordida cruzada bilateral, cavidade nasal sem alterações e submetidos à avaliação da cavidade nasal pré (T1) e sete meses (T2) após a ERMAC, por meio da rinometria acústica. Foram anlisadas as áreas de secção transversais mínimas (ASM) e o volume nasal com e sem uso do vasoconstritor nasal. RESULTADOS: As ASM e volume nasal pré-ERMAC foram menores do que no pós-operatório, com aumento estatisticamente significante nas cavidades nasais direita e esquerda. Houve diferença estatisticamente significante com o uso de vasoconstritor em relação à ASM. O volume das cavidades nasais direita e esquerda não apresentou valores estatisticamente significantes com o emprego de vasoconstritor nasal em relação ao pré-operatório quando comparado ao pós-operatório. CONCLUSÃO: A ERMAC promoveu um aumento da ASM e volume da cavidade nasal. A ASM foi maior com o uso de vasoconstritor, enquanto que o volume nasal não apresentou diferença com ou sem vasoconstritor. / INTRODUCTION: Surgically-assisted rapid maxillary expansion (SARME) is the choice for correcting the deficiency of the transverse maxillary in adult patients. OBJETIVE: To evaluate the effects of SARME using acoustic rhinometry. METHODS: Twenty-seven patients aged between 18-53 years old, with maxillary transverse deficiency larger than five milimeters, bilateral cross-bite, and no evidence of nasal obstruction, and underwent evaluation of nasal cavity by acoustic rhinometry both prior to(T1) and seven months(T2) after SARME. Minor cross-sectional areas and the nasal volume of the right and left nasal cavities were evaluted, such as the use of nasal vasocontrictor. RESULTS: Minor cross-sectional areas and nasal volume pre-ERMAC were lower than in the postoperative period, with a statistically significant increase in both nasal cavity. There was a statistically significant difference with the use of nasal vasoconstrictor in the minor cross-sectional areas. The volume of both nasal cavities showed no differences with the use of vasoconstrictor in preoperative period when compared to postoperative. CONCLUSION: ERMAC increases the minor cross-sectional area and the nasal cavity volume. Minor cross-sectional area is higher after the use of topical nasal vasoconstrictor. The use of topical nasal vasoconstrictor did not change the volume of the nasal cavity. / BV UNIFESP: Teses e dissertações
46

A disjunção pterigomaxilar em expansão rápida de maxila assistida cirurgicamente influencia no volume das vias aéreas superiores? um estudo prospectivo usando Dolphin Imaging 3D / Does the pterigomaxillary disjunction in surgically assisted rapid maxillary expansion to influence the upper airway volume? A prospective study using Dolphin Imaging 3D

Medeiros, José Romulo de January 2015 (has links)
MEDEIROS, José Romulo de. A disjunção pterigomaxilar em expansão rápida de maxila assistida cirurgicamente influencia no volume das vias aéreas superiores? um estudo prospectivo usando Dolphin Imaging 3D. 2015. 48 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by denise santos (denise.santos@ufc.br) on 2015-10-20T13:40:07Z No. of bitstreams: 1 2015_dis_jrmedeiros.pdf: 731747 bytes, checksum: 2fa6a26a8462e7d252c4244adbe54cbc (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-10-20T15:54:09Z (GMT) No. of bitstreams: 1 2015_dis_jrmedeiros.pdf: 731747 bytes, checksum: 2fa6a26a8462e7d252c4244adbe54cbc (MD5) / Made available in DSpace on 2015-10-20T15:54:09Z (GMT). No. of bitstreams: 1 2015_dis_jrmedeiros.pdf: 731747 bytes, checksum: 2fa6a26a8462e7d252c4244adbe54cbc (MD5) Previous issue date: 2015 / The transverse maxillary atresia is a common finding in patients with dentofacial deformities and, in such cases, the surgically assisted rapid maxillary expansion (SARME) has been used as a treatment option. The present study aimed to evaluate the effect of the SARME (with or without pterigomaxilar disjunction [PD]) on the upper airway volume. A prospective study with adult individuals affected by transverse maxillary skeletal deficiency undergoing SARME was performed. The patients were randomly divided into two groups: without PD (−PD); with PD (+PD). Eleven patients per group were estimated to obtain a representative sample (90% of power and a 95% of confidence level). Volumetric images of cone beam computed tomographies were obtained preoperatively (T1), immediately after expander device stabilization (T2) and 6 months after expander device stabilization (T3). Volumetric measurements of the nasal cavity (NCV), maxillary sinuses (MSV), nasopharynx (NFV), oropharynx (OV) and the oropharynx cross-sectional area (OCSA) were obtained using the Dolphin 3D Imaging Software. All statistical analyzes considered a significant value of p <0.05. A total of 322 subjects were evaluated, 25 individuals aged 17 to 49 comprised the sample (DP group, n = 12; group ± SD, n = 13). In the group +PD there was a statistically significant increase during the T2 period for the NFV (p=0.003), OV (p=0.007) and OCSA (p=0.001). There was no statistically significant difference between groups (p <0.05), however, the realization of PD resulted in a significant increase of volumetric measurements of the nasopharynx and MASTO after 6 months of the expander device locking. / A atresia transversa maxilar representa um achado comum em pacientes com deformidades dentofaciais e, nesses casos, tem-se utilizado a expansão rápida de maxila assistida cirurgicamente (ERMAC) como opção de tratamento. O presente estudo objetivou avaliar o efeito da ERMAC (com ou sem disjunção pterigomaxilar [DP]) sobre o volume das vias aéreas superiores. Foi realizado um estudo prospectivo com indivíduos adultos portadores de deficiência esquelética maxilar transversa submetidos à ERMAC. Os pacientes foram aleatoriamente divididos em dois grupos: sem DP (−DP); com DP (+DP). Onze pacientes por grupo foram estimados para se obter uma amostra significativa (poder de 90% e nível de confiança de 95%). Imagens volumétricas de tomografias computadorizadas de feixe cônico foram obtidas pré-operatoriamente (T1), imediatamente após o travamento do dispositivo expansor (T2) e seis meses após o travamento do dispositivo expansor (T3). Por meio do programa Dolphin Imaging 3D, foram obtidas as medidas volumétricas da cavidade nasal (VCN), seios maxilares (VSM), nasofaringe (VNF), orofaringe (VOF), bem como foi obtida a área de secção transversa da orofaringe (MASTO). Todas as análises estatísticas consideraram um valor significativo de p<0,05. Um total de 322 indivíduos foram avaliados, 25 indivíduos com idade entre 17 e 49 anos compuseram a amostra (grupo −DP, n=12; grupo +DP, n=13). No grupo +DP, houve aumento significativo durante o período T2 para o VNF (p=0.003), VOF (p=0.007), e MASTO (p=0.001). Não houve diferença estatisticamente significativa entre os grupos (p<0,05), entretanto, a realização da DP resultou em um aumento significante de medidas volumétricas da nasofaringe e da MASTO, após seis meses do travamento do dispositivo expansor.
47

Influência do número de faces (OD e MOD) e localização da margem gengival em esmalte ou em dentina na infiltração marginal de inlays cerâmicos

Cardoso, Paula de Carvalho January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T18:02:10Z (GMT). No. of bitstreams: 1 202862.pdf: 1700824 bytes, checksum: 520d9f5da7f8622f83acaa603d99430d (MD5) / O estudo avaliou a influência do número de faces e localização da margem gengival na infiltração marginal de inlays cerâmicos. Quarenta pré-molares foram divididos em 4 grupos com 10 dentes cada. No grupo I - MOD, com parede gengival da caixa proximal localizada 1mm aquém da JAC; no grupo II - OD, com margem 1mm aquém da JAC; no grupo III -MOD, com margem gengival 1mm abaixo da JAC e no grupo IV - OD, com margem 1mm abaixo da JAC. Após a moldagem e confecção dos inlays cerâmicos de IPS Empress, os espécimes foram preparados para avaliação da microinfiltração. Conclui-se que os maiores valores de infiltração do corante foram encontrados quando margem gengival localizava-se em dentina. Não houve diferença entre os grupos com diferentes tipos de preparos (DO e MOD).
48

Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura

Gonçalves, Sérgio Eduardo de Paiva [UNESP] 15 December 1994 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:16Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-12-15. Added 1 bitstream(s) on 2015-12-10T14:28:20Z : No. of bitstreams: 1 000023950.pdf: 5255881 bytes, checksum: a5b00e9d9a2096ed77f9f420143ca8d6 (MD5) / Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond... / Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
49

Comparação termométrica entre preparos cavitários realizados com turbinas de alta-rotação e laser de Er:YAG

Cavalcanti, Bruno das Neves [UNESP] 07 November 2001 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-07. Added 1 bitstream(s) on 2015-12-10T14:28:48Z : No. of bitstreams: 1 000143720.pdf: 2203998 bytes, checksum: 0f8fb99f8ca3fb9d8ef894f9e4063677 (MD5) / O objetivo deste estudo foi comparar as variações de temperatura provocadas por turbinas de alta-rotação e pelo laser de Er:YAG (350mJ/10 Hz). Preparos cavitários classe V foram realizados numa profundidade de 2,0mm em 35 incisivos inferiores bovinos, que tiveram um termopar posicionado para ler as temperaturas no interior da câmara pulpar. A análise foi feita nos seguintes grupos: I - alta-rotação sem refrigeração a água; II - alta-rotação com refrigeração a água; III- laser de Er:YAG sem refrigeração a água; IV- laser de Er:YAG com refrigeração a água. Em todos os grupos foram utilizados dez dentes, com exceção do grupo III, que teve uma amostra de apenas cinco dentes, uma vez que foi impossível realizar os preparos adequadamente com o laser sem refrigeração. Os aumentos de temperatura foram gravados num computador ligados aos termopares e os dados dos grupos I, lI e IV foram submetidos ao teste de Dunn para comparações múltiplas (p<0,05). Os aumentos médios de temperatura foram: 11,64°C para o grupo I, 0,96°C para o grupo II, 40,86°C para o grupo lll e 2,9°C para o grupo IV. Não houve diferenças estatisticamente significantes entre os grupos II e IV, e estes foram diferentes do grupo I. Os preparos cavitários realizados com as turbinas de alta-rotação e com o laser de Er:YAG geraram aumentos de temperatura semelhantes quando sob refrigeração a água. A refrigeração é essencial para evitar aumentos de temperatura agressivos em ambos os casos e com o laser de Er:YAG é especialmente necessária para a ablação do esmalte / The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel
50

O aumento nas taxas de implantação embrionária e de gestação obtidas com a colocação da ponta do cateter de transferência embrionária, na área central da cavidade endometrial

Martins, Anice Maria Vieira de Camargo [UNESP] 25 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-25Bitstream added on 2014-06-13T19:26:25Z : No. of bitstreams: 1 martins_amvc_dr_botfm_prot.pdf: 1428441 bytes, checksum: e687eeb3da2bd5d051917dea14402c3d (MD5) / Universidade Estadual Paulista (UNESP) / Fundação para o Desenvolvimento Médico e Hospitalar (Famesp) / O objetivo deste estudo foi determinar a importância do local de transferência embrionária (metade superior ou inferior da cavidade endometrial) nas taxas de implantação e gestação. Metodologia: Foram randomizadas 400 transferências embrionárias, guiadas por ultra-sonografia em dois grupos, de acordo com a distância entre a camada de basal de endométrio fúndico e a ponta do cateter de transferência, no ato do procedimento. O Grupo 1 (n200) correspondeu às transferências sendo realizadas a uma distância <50% do comprimento da cavidade endometrial, isto é, na metade superior da cavidade. O Grupo II (n=200) correspondeu às transferências realizadas a uma distância 50% do comprimento da cavidade endometrial, isto é, na metade inferior da cavidade. Os dados foram avaliados pelos testes t de Student, Mann-Whitney e exato de Fisher. Resultados: As características gerais da população estudada e das transferências tiveram distribuição igualitária (p>0,05) entre Grupos l e II. Não houve diferença estatística entre os grupos com relação às taxas de implantação embrionária (Grupo 1: 16,0%; Grupo II: 16,4% p=0,86) e gestação (Grupo 1: 35,0%; Grupo II: 29,5% p=0,28). Conclusão: As taxas de implantação e gestação são similares, quando os embriões são colocados na metade superior ou inferior da cavidade endometrial. / The objective of the present study was to determine the importance of the site of embryo transfer (upper or lower haif endometrial cavity) on implantation and clinical pregnancy rates. Methods: A total of 400 transfers guided by ultrasound were randomly assigned to two groups according to the distance between the basal layer of fundal endometrium and the catheter tip at the time of embryo placement. Group 1 (n=200) consísted of transfers corresponding to a distance of <50% of the endometrial cavity length, i.e. transfer in upper haif of the cavity; and group li (n=200) consisted of transfers corresponding to a distance of 50% of the endometrial cavity Iength, ie. transfer in lower haif of cavity. The Student's t-test, Mann-Whitney test and Fishers exact test were used where appropriate. Results: The general characteristics of the study population and the main transfer cycle characteristics had an equal distribution (p>0.05) between groups 1 and II. No significant difference in implantation (Group 1: 16.0%; Group II: 16.4% p=0.86) or pregnancy rates (Group 1: 35.0%; Group II: 29.5% p=0.28) was observed between groups 1 and II. Conclusion: The implantation or pregnancy rates were similar whether the embryos were deposited in the upper or lower half of the endometrial cavity.

Page generated in 0.073 seconds