31

Klimatizace jednoho podlaží administrativní budovy / Air - conditioning of office building

Balcar, Petr January 2012 (has links)
The main goal of the submitted thesis is the design of central conditioning system used to ensure the required internal microclimate of office space and meeting rooms on the 2nd floor of office building, located in the city of Brno. The first part provides an overview of air conditioning systems and the appropriate central air conditioning system is selected. In the next part is designed the devices for air conditioning by building layout, properties of building structures, equipment and office space occupied. The work also submits drawing documentation, technical report and specification of materials used.
32

Industrialization and Immigration: Labor at the River's Bend

Miceli, Stephen R. 16 June 2009 (has links)
No description available.
33

Optimalizace chlazení RD využívajícího zemní vrty / Optimization of cooling of a family house by using a geothermal system

Buchta, Jan January 2015 (has links)
The master’s thesis deals with optimization of cooling system of family house using borehole heat exchanger as a single cooling source. In the experimental part of the thesis was carried out long-term mearurements. The main part of the master’s thesis is the development and verification mathematical and physical model of thermal behavior chilled room. The result are computer simulations and evaluation of individual scenarios and design requirements for a potential optimization of measurement and control system. The theoretical part generally deals with radiant cooling systems.
34

Biurų pastatų naudojant skirtingus šilumnešius vėsinimas / Cooling of office buildings using different coolants

Kanapienytė, Rasa 15 June 2011 (has links)
Baigiamajame magistro darbe nagrinėjama problema – dideli energijos poreikiai vėsinimui biurų pastatuose, dėl vis didėjančių mikroklimato kokybės reikalavimų, didesnių šilumos pritekėjimų į patalpas ir šilumos išsiskyrimų dėl naudojamos įrangos. Problemos sprendimui darbe suprojektuotos keturios oro kondicionavimo sistemos su skirtingais šilumnešiais: oru, vandeniu ir freonu. Atsižvelgiant į šilumnešio tipą suprojektuotos ventiliatorinių konvektorių, aktyviųjų šalčio sijų, freoninė ir orinė vėsinimo sistemos. Oro kondicionavimo sistemos analizuojamos remiantis realaus tipinio administracinio pastato pavyzdžiu. Lyginamoms sistemoms buvo atlikti hidrauliniai ir aerodinaminiai skaičiavimai, įvertintos sistemų pradinės investicijos, apskaičiuotos energijos sąnaudos ir eksploatacijos išlaidos. Ekonominio skaičiavimo metu buvo įvertintas sistemų atsipirkimo laikas ir atlikta elektros kainų jautrumo analizė. Šio tyrimo rezultatai parodo, kokia sistema iš visų darbe nagrinėtųjų sistemų yra tinkamiausia biurų pastatams, pagal efektyvų elektros energijos naudojimą ir pradines investicijas. / The final master's work deals with the problem of high energy needs for cooling in office buildings, due to the growing of higher quality requirements for microclimate, higher heat gains in premises and equipment heat emissions used in. To solve the problem four different types of cooling systems with different coolants: air, water and refrigerant are designed at work. Depending on the type of coolant were designed fan coil units, active chilled beams, variable refrigerant volume system and air cooling systems. Air conditioning systems are analyzed on the basis of an example of the real typical office building. The hydraulic and aerodynamic calculations were made, initial investments, energy expenditures and operating costs were estimated for the compared systems. The pay-back time of the systems was assessed and the sensitivity analysis of electricity prices was carried out by economic calculations. The results of this investigation show, which system of all analysed systems at work is the most appropriate for office buildings, according to the efficient use of electricity and the initial investments.
35

Multi-agent based control of large-scale complex systems employing distributed dynamic inference engine

Zhang, Daili 26 March 2010 (has links)
Increasing societal demand for automation has led to considerable efforts to control large-scale complex systems, especially in the area of autonomous intelligent control methods. The control system of a large-scale complex system needs to satisfy four system level requirements: robustness, flexibility, reusability, and scalability. Corresponding to the four system level requirements, there arise four major challenges. First, it is difficult to get accurate and complete information. Second, the system may be physically highly distributed. Third, the system evolves very quickly. Fourth, emergent global behaviors of the system can be caused by small disturbances at the component level. The Multi-Agent Based Control (MABC) method as an implementation of distributed intelligent control has been the focus of research since the 1970s, in an effort to solve the above-mentioned problems in controlling large-scale complex systems. However, to the author's best knowledge, all MABC systems for large-scale complex systems with significant uncertainties are problem-specific and thus difficult to extend to other domains or larger systems. This situation is partly due to the control architecture of multiple agents being determined by agent to agent coupling and interaction mechanisms. Therefore, the research objective of this dissertation is to develop a comprehensive, generalized framework for the control system design of general large-scale complex systems with significant uncertainties, with the focus on distributed control architecture design and distributed inference engine design. A Hybrid Multi-Agent Based Control (HyMABC) architecture is proposed by combining hierarchical control architecture and module control architecture with logical replication rings. First, it decomposes a complex system hierarchically; second, it combines the components in the same level as a module, and then designs common interfaces for all of the components in the same module; third, replications are made for critical agents and are organized into logical rings. This architecture maintains clear guidelines for complexity decomposition and also increases the robustness of the whole system. Multiple Sectioned Dynamic Bayesian Networks (MSDBNs) as a distributed dynamic probabilistic inference engine, can be embedded into the control architecture to handle uncertainties of general large-scale complex systems. MSDBNs decomposes a large knowledge-based system into many agents. Each agent holds its partial perspective of a large problem domain by representing its knowledge as a Dynamic Bayesian Network (DBN). Each agent accesses local evidence from its corresponding local sensors and communicates with other agents through finite message passing. If the distributed agents can be organized into a tree structure, satisfying the running intersection property and d-sep set requirements, globally consistent inferences are achievable in a distributed way. By using different frequencies for local DBN agent belief updating and global system belief updating, it balances the communication cost with the global consistency of inferences. In this dissertation, a fully factorized Boyen-Koller (BK) approximation algorithm is used for local DBN agent belief updating, and the static Junction Forest Linkage Tree (JFLT) algorithm is used for global system belief updating. MSDBNs assume a static structure and a stable communication network for the whole system. However, for a real system, sub-Bayesian networks as nodes could be lost, and the communication network could be shut down due to partial damage in the system. Therefore, on-line and automatic MSDBNs structure formation is necessary for making robust state estimations and increasing survivability of the whole system. A Distributed Spanning Tree Optimization (DSTO) algorithm, a Distributed D-Sep Set Satisfaction (DDSSS) algorithm, and a Distributed Running Intersection Satisfaction (DRIS) algorithm are proposed in this dissertation. Combining these three distributed algorithms and a Distributed Belief Propagation (DBP) algorithm in MSDBNs makes state estimations robust to partial damage in the whole system. Combining the distributed control architecture design and the distributed inference engine design leads to a process of control system design for a general large-scale complex system. As applications of the proposed methodology, the control system design of a simplified ship chilled water system and a notional ship chilled water system have been demonstrated step by step. Simulation results not only show that the proposed methodology gives a clear guideline for control system design for general large-scale complex systems with dynamic and uncertain environment, but also indicate that the combination of MSDBNs and HyMABC can provide excellent performance for controlling general large-scale complex systems.
36

Dynamic thermal response of the data center to cooling loss during facility power failure

Shields, Shawn 01 July 2009 (has links)
Provisioning for power failure is an important element of data center design. It is important to assess both tangible and intangible costs of unplanned data center downtime. These costs must be compared with the capital cost of providing various levels of backup power infrastructure to compute and cooling equipment. Various levels of backup power infrastructure each lead to a most probable transient scenario after utility power failure. Because of differences between facilities, the level of risk that unacceptable compute equipment inlet temperature associated with each level of backup power infrastructure is not standardized; in particular, facilities with differing compute equipment power densities may require different levels of backup power infrastructure to maintain safe operation. Choosing one level of backup power infrastructure above another is not necessarily obvious for every facility, as there may be large gaps in costs and unknown levels of risk for lower levels of provisioning. A first order model is also used to compare inclusion of various thermal capacitance values with experimental results. Room level experiments also illustrate the relative level of risk associated with various levels of provisioning for the same control volume and compute equipment. Although provisioning to back up as much equipment as possible remains the "safest" solution, cost will continue to play a factor in facility design decisions. This work offers a step toward appropriate modeling of data center power failure events and suggests further steps to continue the process.
37

Infer?ncia do ponto de orvalho em amostras de g?s natural processado

Paz, Sidrak Jos? da 20 December 2011 (has links)
Made available in DSpace on 2014-12-17T15:01:27Z (GMT). No. of bitstreams: 1 SidrakJP_DISSERT.pdf: 3365381 bytes, checksum: 55b6f324d82bc4f385aa87921831ed44 (MD5) Previous issue date: 2011-12-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This dissertation aims to assess the representativeness of the manual chilled mirror analyzer (model II Chanscope 13-1200-CN-2) used for the determination of condensed hydrocarbons of natural gas compared to the indirect methods, based on thermodynamic models equation of state. Additionally, it has been implemented in this study a model for calculating the dew point of natural gas. The proposed model is a modification of the equation of state of Peng-Robinson admits that the groups contribution as a strategy to calculate the binary interaction parameters kij (T) temperature dependence. Experimental data of the work of Brown et al. (2007) were used to compare the responses of the dew point of natural gas with thermodynamic models contained in the UniSim process simulator and the methodology implemented in this study. Then two natural gas compositions were studied, the first being a standard gas mixture gravimetrically synthesized and, second, a mixture of processed natural gas. These experimental data were also compared with the results presented by UniSim process simulator and the thermodynamic model implemented. However, data from the manual analysis results indicated significant differences in temperature, these differences were attributed to the formation of dew point of water, as we observed the appearance of moisture on the mirror surface cooling equipment / O presente trabalho de disserta??o tem por objetivo avaliar a representatividade do analisador manual de espelho refrigerado (Chanscope II modelo 13-1200-C-N-2) usado para a determina??o do condensado de hidrocarbonetos de g?s natural frente aos m?todos indiretos, fundamentados em modelos termodin?micos de equa??o de estado. Adicionalmente, tem sido implementado neste estudo um modelo para c?lculo do ponto de orvalho de g?s natural. O modelo proposto constitui uma modifica??o na equa??o de estado de Peng-Robinson que admite a contribui??o de grupos como estrat?gia para calcular os par?metros de intera??o bin?ria kij(T) com depend?ncia da temperatura. Dados experimentais do trabalho de Brown et al. (2007) foram utilizados para comparar as respostas de ponto de orvalho do g?s natural com os modelos termodin?micos contidos no simulador de processo UniSim e com a metodologia implementada neste estudo. Em seguida, duas composi??es de g?s natural foram estudadas, sendo a primeira uma mistura padr?o de g?s sintetizada gravimetricamente e, a segunda, uma mistura de g?s natural processado. Tais dados experimentais foram tamb?m comparados com os resultados apresentados pelo simulador de processo UniSim e pelo modelo termodin?mico implementado. No entanto, os dados do analisador manual indicaram diferen?as significativas nos resultados de temperaturas, sendo estas diferen?as atribu?das ? forma??o de ponto de orvalho de ?gua, j? que foi observado o aparecimento de umidade sobre a superf?cie do espelho refrigerado do equipamento
38

CO2 capture in industry using chilled ammonia process / CO2-fångst i industrin med kyld ammoniakprocess

Amara, Soumia January 2021 (has links)
CO2 capture and storage (CCS) is estimated to reduce 14% of the global CO2 emissions in the 2 °C scenario presented by the International Energy Agency. Moreover, post combustion capture is identified as a potential method for CO2 capture from industry since it can be easily retrofitted without disturbing the core industrial process. Among the post-combustion capture methods, absorption using mono-ethanol amine (MEA) is the most mature technology that has been demonstrated at plant scale. However, using chilled ammonia process as a post combustion capture technology in a cement industry can reduce 47% energy penalty for CO2 capture when compared to the conventional MEA absorption method.  Hence, the current project aims at analyzing the chilled ammonia process when integrated with steel and ammonia plants. Key performance indicator like specific primary energy consumption per kilogram of CO2 avoided (SPECCA) is estimated and compared with MEA absorption method. Firstly, chilled ammonia process (CAP) for cement plant was used as reference case. Then, CAP for steel and ammonia processes was optimized by the means of the decision variables affecting the capture and energy efficiency. The energy consumption per kg CO2 captured and SPECCA was lower for the higher CO2 concentration in the flue gas. Results for SPECCA were 3,56, 3,52 and 3,61 MJ/kg CO2 for cement, steel, and ammonia plants, respectively.
39

Vzduchotechnika hotelového komplexu / Air Conditioning of Hotel Komplex

Očkan, Tomáš January 2014 (has links)
The first part of the thesis is aimed on creating internal microclimate of the hotel complex by air conditioning systems. The choice of systems is based on theoretical knowledge’s and practical application in abroad. In the second part there is designed solution for hotel apartments and conference hall. The other areas are designed only conceptual. Technical solutions of chosen systems are the main outcome of the thesis. In the third part there are published my experimental measurements from laboratories of Oulu University of Applied Sciences. For the study field of Air Conditioning has been chosen Air Flow Measurement and Test Operation of HVAC unit. For the study field of Renewable Energy has been chosen the Heat Pump and for study field of Refrigeration has been chosen Water Cooling and Chiller Box.