1

Análise da alteração de cor promovida por materiais reparadores e cimentos endodônticos à base de silicato de cálcio com diferentes radiopacificadores /

Inada, Rafaela Nanami Handa January 2018 (has links)
Orientador: Mário Tanomaru Filho / Resumo: Materiais reparadores e cimentos endodônticos não devem promover alteração da coloração dental. Este estudo foi dividido em 3 publicações. Publicação 1 - avaliação da alteração cromática dentária promovida por cimentos de silicato tricálcico (TSC) associado com óxido de bismuto (TC-Bi), óxido de zircônio (TC-Zr), óxido de nióbio (TC-Nb) e Biodentine (BD). Publicação 2 - comparação dos efeitos cromáticos induzidos por cimentos TSC-Bi e silicato tricálcio com tungstato de cálcio (TSC-TC), MTA Angelus (MTA) e MTA HP Repair (MTAHP). Publicação 3 - avaliação das alterações cromáticas por cimentos endodônticos, AH Plus (AHP), MTA Fillapex (MTAF), Total Fill BC Sealer (TF) e NeoMTA Plus (NMTAP). Dentes bovinos (n=10) foram seccionados para obtenção de secções vestibulares e palatinos. Na face interna vestibular foram realizadas duas cavidades, uma na porção coronária e outra radicular, que foram preenchidas pelos materiais em estudo e com pasta triantibiótica como controle positivo (CP) e cavidades sem material como controle negativo (CN). A mensuração da alteração cromática (∆E) e luminosidade (L*) foram realizadas com espectrofotômetro, antes da inserção dos materiais (T0), imediatamente após a inserção (T1) e após 7 (T7), 15 (T15), 30 (T30), 60 (T60), 120 (T120) e 180 (T180) dias. Os dados foram avaliados por meio de teste de Análise de Variância de medidas repetidas a dois critérios e Post Hoc teste LSD-Fisher, ambos com nível de significância de 5%. Publicação 1 - na porção cor... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Repair materials and endodontic sealers should not promote tooth staining. This study was divided into 3 publications. Publication 1 - evaluation of dental discoloration of tricalcium silicate (TSC) cements associated with bismuth oxide (TC-Bi), zirconium oxide (TC-Zr), niobium oxide (TC-Nb) and Biodentine (BD). Publication 2 - comparison of the color effects induced by TSC-Bi cements and tricalcium silicate with calcium tungstate (TSC-TC), MTA Angelus (MTA) and MTA HP Repair (MTAHP). Publication 3 - evaluation of color changes by endodontic cements, AH Plus (AHP), MTA Fillapex (MTAF), Total Fill BC Sealer (TF) and NeoMTA Plus (NMTAP). Bovine teeth were sectioned to obtain vestibular and palatine sections. In the internal vestibular face, two cavities were performed, one in the coronary portion and the other one in the root, which were filled with the materials, and triantibiotic paste as the positive control (CP) and cavities with no filling as the negative control (CN). The measurement of the color change (ΔE) was performed with a spectrophotometer, before insertion of the materials (T0), immediately after insertion (T1) and after 7 (T7), 15 (T15), 30 (T30), 60 (T60), 120 (T120) and 180 (T180) days. The data were evaluated by Variance Analysis of repeated measurements at two criteria and Post Hoc LSD-Fisher test, both with a significance level of 5%. Publication 1 - in the coronary portion TSC and CP presented higher ΔE in T180 compared to T1 (p <0,05). Only TSC-Zr and TSC-... (Complete abstract click electronic access below) / Mestre
2

Biocompatibilidade e bioatividade de cimentos à base de silicato tricálcico : estudo in vitro e in vivo /

Andrade, Aline Silva. January 2016 (has links)
Orientador: Mario Tanomaru Filho / Banca: Gisele Faria / Banca: Marco Antônio Húngaro Duarte / Resumo: Cimentos à base de silicato tricálcico são desenvolvidos como alternativa ao Mineral Trióxido Agregado (MTA). O objetivo do estudo foi avaliar a biocompatibilidade e bioatividade do cimento experimental silicato tricálcico com 20% de óxido de zircônio (ZrO2) (STC) e MTA Plus (MTAP). Capítulo1- Células humanas de osteoblastos (Saos-2) foram utilizadas para análise da viabilidade celular por meio dos ensaios de MTT e Vermelho Neutro (NR), da bioatividade pela atividade da enzima fosfatase alcalina (ALP) e da presença de área mineralizada pela coloração de Vermelho de Alizarina (ARS). Os dados obtidos para MTT, NR e ALP foram analisados por ANOVA e Bonferroni, e ARS, por ANOVA e Tukey (p ≤ 0,05). Nos ensaios de viabilidade celular, os materiais não foram citotóxicos. Maior atividade de ALP ocorreu aos 7 dias para todos materiais avaliados. Área mineralizada foi observada em todos os grupos, sendo menor para o grupo STC. Concluiu-se que o cimento experimental silicato tricálcico com 20% de óxido de zircônio e MTA Plus apresentam citocompatibilidade e potencial bioativo. Capítulo 2- A reação inflamatória induzida pelo STC e MTAP foi investigada em subcutâneo de ratos. Tubos de polietileno foram preenchidos com STC (n= 20) e MTAP (n= 20) e implantados no subcutâneo dorsal de quarenta ratos. No grupo controle (GC; n= 20), tubos vazios foram implantados. Após 7, 15, 30 e 60 dias, os tubos de polietileno com o tecido conjuntivo circundante foram fixados e embebidos em parafina. O núme... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Tricalcium silicate- based cements have been developed as an alternative to Mineral Trióxido Agregado (MTA). The aim of the study was to evaluate biocompatibility and bioactivity of the tricalcium silicate cement replaced with 20% zirconium oxide (STC) e MTA Plus (MTAP). Chaper 1- Human osteoblastic cells (Saos-2) were exposed to test materials and assessed for viability, MTT and Neutral Red (NR) assay, and bioactivity for ALP activity assay and alizarin red staining (ARS). Unexposed cells acted as the control group. Statistical analysis was performed using ANOVA and the Bonferroni post- test (P < 0.05) to MTT, NR and ALP, and ANOVA and Tukey post- test (P ≤ 0.05) to ARS. MTT and NR results, all tested cements were non-cytotoxic. The highest ALP activity occurred at the 7th days. Mineralized area was observed in all materials, STC group showed lower mineralized area. Experimental tricalcium silicate with 20% zirconium oxide and MTA Plus have present biocompatibility and bioactive potential. Chapter 2- The inflammatory reaction induced by tricalcium silicate cement replaced with 20% zirconium oxide (STC) e MTA Plus (MTAP) was evaluated in rat subcutaneous tissues. A polyethylene tube filled with STC (n= 20) and MTAP (n= 20) was placed into the dorsal subcutaneous of forty rats; in the control group (GC; n= 20), empty tubes were implanted. After 7, 15, 30 and 60 days, the polyethylene tubes surrounded by connective tissue were embedded in paraffin. The number of inflammatory ce... (Complete abstract click electronic access below) / Mestre
3

Análise de cimentos à base de silicato de cálcio associado a diferentes radiopacificadores /

Costa, Bernardo Cesar. January 2016 (has links)
Orientador: Mario Tanomaru-Filho / Resumo: O MTA e cimento Portland (PC) são cimentos de silicato de cálcio. O óxido de bismuto presente na MTA pode afetar as propriedades físico-químicas e biológicas do material. Novos radiopacificadores como óxido de itérbio (Yb2O3) e o tungstato de cálcio (CaWO4) podem melhorar propriedades do material. No capítulo 1, foram realizadas avalições de propriedades físico-químicas, citotoxicidade e potencial bioativo do MTA Angelus (MTA), cimento de silicato de cálcio (CSC) e CSC com 30% de óxido de Itérbio (CSC/Yb2O3). O tempo de presa inicial e final foi avaliado com agulhas Gilmore. A resistência à compressão foi analisada em máquina de ensaios mecânicos. A radiopacidade foi verificada com radiografias dos materiais e escala de alumínio. O teste de solubilidade e escoamento foram realizados de acordo com ISO 6876/2002. Os dados foram submetidos ao teste ANOVA e Tukey (5% de significância). A viabilidade celular foi avaliada por meio do ensaio MTT e corante Vermelho Neutro, enquanto o potencial de mineralização por meio da atividade de fosfatase alcalina e vermelho de Alizarina. Os dados foram submetidos aos testes Anova e Tukey e Bonferroni (5% de significância). O potencial bioativo foi avaliado em microcopia eletrônica de varredura. No capítulo 2, materiais à base de silicato tricálcico (TSC) associado ao tungstato de cálcio (CaWO4) e Yb2O3 foram avaliados em comparação ao MTA (Angelus, Londrina, Brasil) e ao TSC. O tempo de presa inicial e final foi avaliado com agulhas Gilmore. A... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
4

AVALIAÇÃO DA GENOTOXICIDADE E MUTAGENICIDADE DO BIODENTINE / EVALUATION OF GENOTOXICITY AND MUTAGENICITY OF BIODENTINE

Logar, Gustavo de Almeida 23 May 2014 (has links)
Made available in DSpace on 2016-01-26T18:55:40Z (GMT). No. of bitstreams: 1 Gustavo Logar.pdf: 371330 bytes, checksum: 461b03ba76909955dcf6db3c8b004b60 (MD5) Previous issue date: 2014-05-23 / The Biodentine is a new material suitable for various clinical situations in dentistry. Despite being a promising material, there are few studies evaluating the characteristics of this material, especially its genotoxicity and mutagenicity. Objective: This study aims to evaluate the genotoxic and mutagenic potential of Biodentine "in vivo". Methods: We used 24 Wistar albino rats, males were divided into 3 groups: A - 8 rats where specimens of Biodentine measuring 2 mm in diameter x 10mm length on the dorsum were placed, B - 8 rats, which received cyclophosphamide in single subcutaneous dose (50mg/kg) on the first day of the experiment (positive control group), C - 8 rats where specimens measuring 2 mm in diameter x 10mm long without Biodentine on the dorsum were placed (negative control group). After 24 hours, all animals were euthanized and material from bone marrow of femurs was collected to perform the Comet assay and micronucleus test. Results: Biodentine showed levels of DNA damage (tail intensity %) in bone marrow cells of 23.57 ± 7.70, cyclophosphamide of 27,43 ± 7,40 and negative control of 24.75 ± 5 55 (p < 0.05). The average number of micronuclei in the exposed Biodentine group was 6.25 (standard deviation - SD = 3.53), in the group exposed to cyclophosphamide was 9.75 (SD = 2.49) and negative control group was 0.75 (SD = 1.03) (p < 0.0001). Conclusion: The Biodentine showed an increase in the frequency of micronuclei, but no genotoxicity effect by the Comet assay. / O Biodentine é um novo material indicado para diversas situações clínicas na odontologia. Apesar de ser um material promissor, ainda há poucos trabalhos avaliando as características deste material, em especial sua genotoxicidade e mutagenicidade. Objetivo: Este estudo visa avaliar o potencial genotóxico e mutagênico do Biodentine in vivo . Material e métodos: Foram utilizados 24 ratos Wistar albinos, machos, distribuídos em 3 grupos: A 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento com Biodentine no subcutâneo do dorso; B 8 ratos, que receberam ciclofosfamida em dose única subcutânea (50mg/kg) no primeiro dia do experimento (grupo controle positivo); C 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento sem Biodentine no subcutâneo do dorso (grupo controle negativo). Após 24 horas, todos os animais foram eutanasiados e material da medula óssea dos fêmures foi coletado para realização do Teste do Cometa e do Teste do micronúcleo. Resultados: O Biodentine apresentou níveis de danos no DNA (tail intensity %) em células da medula óssea de 23,57 ± 7,70, a ciclofosfamida de 27,43 ± 7,40 e o controle negativo de 24,75 ± 5,55 (p<0,05). A média de micronúcleos no grupo exposto ao Biodentine foi de 6,25 (desvio padrão DP= 3,53), no grupo exposto a ciclofosfamida foi de 9,75 (DP= 2,49) e no grupo de controle negativo foi 0,75 (DP= 1,03) (p<0,0001). Conclusão: O Biodentine apresentou aumento na frequência de micronúcleos, mas não apresentou efeito genotóxico observado pelo teste do Cometa.
5

AVALIAÇÃO DA GENOTOXICIDADE E MUTAGENICIDADE DO BIODENTINE / EVALUATION OF GENOTOXICITY AND MUTAGENICITY OF BIODENTINE

Logar, Gustavo de Almeida 23 May 2014 (has links)
Made available in DSpace on 2016-07-18T17:53:13Z (GMT). No. of bitstreams: 1 Gustavo Logar.pdf: 371330 bytes, checksum: 461b03ba76909955dcf6db3c8b004b60 (MD5) Previous issue date: 2014-05-23 / The Biodentine is a new material suitable for various clinical situations in dentistry. Despite being a promising material, there are few studies evaluating the characteristics of this material, especially its genotoxicity and mutagenicity. Objective: This study aims to evaluate the genotoxic and mutagenic potential of Biodentine "in vivo". Methods: We used 24 Wistar albino rats, males were divided into 3 groups: A - 8 rats where specimens of Biodentine measuring 2 mm in diameter x 10mm length on the dorsum were placed, B - 8 rats, which received cyclophosphamide in single subcutaneous dose (50mg/kg) on the first day of the experiment (positive control group), C - 8 rats where specimens measuring 2 mm in diameter x 10mm long without Biodentine on the dorsum were placed (negative control group). After 24 hours, all animals were euthanized and material from bone marrow of femurs was collected to perform the Comet assay and micronucleus test. Results: Biodentine showed levels of DNA damage (tail intensity %) in bone marrow cells of 23.57 ± 7.70, cyclophosphamide of 27,43 ± 7,40 and negative control of 24.75 ± 5 55 (p < 0.05). The average number of micronuclei in the exposed Biodentine group was 6.25 (standard deviation - SD = 3.53), in the group exposed to cyclophosphamide was 9.75 (SD = 2.49) and negative control group was 0.75 (SD = 1.03) (p < 0.0001). Conclusion: The Biodentine showed an increase in the frequency of micronuclei, but no genotoxicity effect by the Comet assay. / O Biodentine é um novo material indicado para diversas situações clínicas na odontologia. Apesar de ser um material promissor, ainda há poucos trabalhos avaliando as características deste material, em especial sua genotoxicidade e mutagenicidade. Objetivo: Este estudo visa avaliar o potencial genotóxico e mutagênico do Biodentine in vivo . Material e métodos: Foram utilizados 24 ratos Wistar albinos, machos, distribuídos em 3 grupos: A 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento com Biodentine no subcutâneo do dorso; B 8 ratos, que receberam ciclofosfamida em dose única subcutânea (50mg/kg) no primeiro dia do experimento (grupo controle positivo); C 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento sem Biodentine no subcutâneo do dorso (grupo controle negativo). Após 24 horas, todos os animais foram eutanasiados e material da medula óssea dos fêmures foi coletado para realização do Teste do Cometa e do Teste do micronúcleo. Resultados: O Biodentine apresentou níveis de danos no DNA (tail intensity %) em células da medula óssea de 23,57 ± 7,70, a ciclofosfamida de 27,43 ± 7,40 e o controle negativo de 24,75 ± 5,55 (p<0,05). A média de micronúcleos no grupo exposto ao Biodentine foi de 6,25 (desvio padrão DP= 3,53), no grupo exposto a ciclofosfamida foi de 9,75 (DP= 2,49) e no grupo de controle negativo foi 0,75 (DP= 1,03) (p<0,0001). Conclusão: O Biodentine apresentou aumento na frequência de micronúcleos, mas não apresentou efeito genotóxico observado pelo teste do Cometa.
6

Resposta dos tecidos periodontais aos cimentos de silicato tricálcico associado ao óxido de zircônio ou óxido de nióbio usados no selamento de perfurações de furca em molares de ratos /

Barbosa, Derik Damasceno. January 2016 (has links)
Orientador: Paulo Sérgio Cerri / Banca: Lea Assed Bezerra da Silva / Banca: Mario Tanomaru Filho / Resumo: Perfurações radiculares acidentais ocorrem em cerca de 2-12% dos dentes tratados endodonticamente. Estas perfurações causam injúria aos tecidos periodontais adjacentes e, frequentemente, promovem a invasão bacteriana culminando com a inflamação do ligamento periodontal e reabsorção óssea podendo levar a perda do elemento dental. Dentre os materiais indicados para o selamento destas perfurações, o MTA tem sido largamente usado. O MTA é basicamente composto por silicatos de cálcio (80%) e óxido de bismuto (Bi2O3; 20%), usado como agente radiopacificador. Silicato tricálcico (STC) é um biomaterial utilizado associado ao óxido de zircônio (ZrO2) e o óxido de nióbio (Nb2O5) é um radiopacificador alternativo. O objetivo deste estudo foi avaliar a resposta dos tecidos periodontais promovida pelo silicato tricálcico puro (Mineral Research Processing, Meyzieu, França) associado ao ZrO2 ou ao Nb2O5 comparando-os ao MTA-Angelus, em perfuração de furca de molares de ratos. Foram utilizados 80 ratos, distribuídos em 4 grupos: GS (sham), STC+ZrO2, STC+Nb2O5 e GMTA, de acordo com o material de selamento. No grupo GS, as perfurações no assoalho da câmara pulpar não foram seladas. O acesso da cavidade foi restaurado com cimento de ionômero de vidro fotopolimerizável. Os 1os molares esquerdos, sem perfurações no assoalho da câmara pulpar, foram usados como controle (GC). Após os períodos de 7, 15, 30 e 60 as maxilas foram removidas, fixadas, descalcificadas e incluídas em parafina. Os cortes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Accidental radicular perforation occurs in about 2-12% of endodontically treated teeth. These perforations lead to injury of periodontal tissues and frequently promote bacterial invasion inducing to periodontal ligament inflammation and bone resorption may lead to tooth loss. Among the materials suitable for the sealing of these perforations, the MTA has been widely used. MTA is basically composed of calcium silicate (80%) and bismuth oxide (Bi2O3, 20%), a radiopacifying agent. Tricalcium silicate (TCS) is a biomaterial used associated with zirconium oxide (ZrO2) and niobium oxide (Nb2O5) is an alternative radiopacifier. Our purpose was to evaluate response of the periodontium adjacent to furcation perforations in rat molars filled with pure tricalcium silicate (Mineral Research Processing, Meyzieu, France) associated with ZrO2 or Nb2O5 and MTA-Angelus. Eighty rats were distributed into four groups: SG (sham), TCS+ZrO2, TCS+Nb2O5 and MTAG according to the sealing material. In the SG group, the perforations in the pulp chamber floors were not sealed. The access cavity was restored with light-cure glass-ionomer cement. The left upper first molars, without perforations in the pulp chamber floors, were used as controls (CG). After 7, 15, 30 and 60 days, fragments of maxilla were fixed, decalcified and embedded in paraffin. In the HE-stained sections, the volume density of inflammatory cells (VvIC), fibroblasts (VvFb) and blood vessels (VvBV) was obtained. The width of the periodo... (Complete abstract click electronic access below) / Mestre
7

Cimento de silicato de cálcio modificado com nanopartículas de vidro bioativo para aplicação como substituto de dentina /

Corral Núñez, Camila María. January 2017 (has links)
Orientador: Hernane da Silva Barud / Resumo: Os cimentos de silicato de cálcio têm se desenvolvido rapidamente durante as últimas décadas; com a aparição de novos cimentos para uso em odontologia restauradora. Estes cimentos apresentam diferentes composições químicas e por tanto provavelmente diferente radiopacidade. A incorporação de nanopartículas de vidro bioativo poderia melhorar a bioatividade dos cimentos de silicato de cálcio. O objetivo foi avaliar a composição química e radiopacidade dos cimentos a base de silicato de cálcio Biodentine (BD) e TheraCal LC e a contribuição do acréscimo de nanopartículas de vidro bioativo (nVB) no BD. Método: Foram realizados testes de radiopacidade de acordo com norma ISO 9917 e caracterização com microscopia eletrônica de varredura e análise elementar (MEV/EDX) dos novos cimentos de silicato de cálcio BD e TheraCal LC. Posteriormente, nVB foram sintetizadas com técnica sol-gel, e foram preparados nanocompósitos do BD com 1 e 2% em peso de nVB (1%nVB/BD e 2%nVB/BD). A bioatividade dos nanocompósitos foi avaliada in vitro e caracterizado com MEV/EDX, análise de espectroscopia no infravermelho por transformada de Fourier e difração de raios-X (DRX). Também os nanocompósitos foram aplicados em discos de dentina e a interface caracterizada com MEV-EDX. Resultados: BD apresentou zircônio como elemento radiopacificante e maiores valores de radiopacidade do que o TheraCal LC, que apresentou bário, estrôncio e zircônio como radiopacificadores. A incorporação de nVBs em BD melhorou a bioa... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
8

Efeito do preparo rotatório e reciprocante no canal e dentina radicular e na qualidade da obturação, usando cimentos a base de silicato de cálcio /

Mendes, Camila Almeida Nascimento. January 2017 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Os instrumentos de níquel-titânio usados durante o preparo dos canais radiculares podem sofrer diferentes processos de tratamento na liga durante a fabricação. Sistemas de instrumentação mecanizada apresentam formatos individuais dos instrumentos, sendo sugeridas diversas cinemáticas de atuação durante a ação de corte da dentina. Os sistemas de único instrumento usados em cinemática reciprocante e novos instrumentos com tratamento térmico das ligas devem ser estudados quanto ao efeito sobre o preparo do canal e dentina radicular. A anatomia do canal, as técnicas obturadoras e o emprego de diferentes materiais podem influenciar na qualidade da obturação. O objetivo do estudo foi avaliar o preparo de canais achatados de incisivos inferiores e canais mesiais de molares inferiores com instrumento rotatório e/ou reciprocante, bem como a qualidade da obturação usando diferentes técnicas ou cimento de silicato de cálcio. Noventa incisivos inferiores apresentando canais achatados foram preparados com sistema Mtwo em rotação contínua (Mtwo rot) até 40/.06; Mtwo 40/.06 instrumento único em cinemática reciprocante horária (Mtwo rec) e Reciproc (R40) (n=30). Os dentes foram escaneados por microtomografia computadorizada (Micro-CT) antes e após o preparo. Os dados foram expressos em porcentagem do aumento de volume do canal (%V), redução da espessura de dentina (%DTR), área de superfície não instrumentada (%S) e debris remanescente (%D). O tempo necessário para o preparo foi anotado. Cana... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The nickel-titanium instruments used during the preparation of root canals can present different treatment processes in alloy during manufacturing. Mechanized instrumentation systems present instruments with individual formats, being suggested various kinematics during the action on the dentin. Single instrument systems used in reciprocating kinematics and the new instruments with thermal treatment of alloys should be studied as to the effect on the preparation of the root canal and dentin. The anatomy of the root canal, the filling techniques and the use of different materials can influence in the quality of filling. The objective of this study was to evaluate the flattened root canal preparation of mandibular incisors and mesial root canals mandibular molars using rotatory and/or reciprocating instruments, as well the quality of root canal obturation using different techniques or calcium silicate sealer. Ninety mandibular incisors presenting flattened canals were prepared using Mtwo system in continuous rotation (Mtwo rot) up to 40/.06; Mtwo 40/.06 single instrument in reciprocating motion (Mtwo rec) and Reciproc (R40) (n = 30). The teeth were scanned by computed microtomography (Micro-CT) before and after the preparation. Data were expressed as a percentage of the increase in volume of root canal (% V), reduction of the thickness dentin (% DTR), uninstrumented surface area (% S) and remaining debris (% D). The time required for the preparation was noted. Mesial root canals... (Complete abstract click electronic access below) / Doutor