Short-circuit current calculations and protective relay coordination for industrial and commercial power systemsMohammadi, Houshang January 1986 (has links)
No description available.
|
12 |
Estimação computacional dos esforços eletromecânicos em transformadores de potência no sistema CHESF.CALHEIROS JUNIOR, Eduardo Jorge. 06 February 2018 (has links)
Submitted by Gustavo Nascimento (gustavo.diniz@ufcg.edu.br) on 2018-02-06T14:28:39Z
No. of bitstreams: 1
EDUARDO JORGE CALHEIROS JUNIOR - DISSERTACAO PPGEE 2014.pdf: 3431884 bytes, checksum: 5d6e954510b9e7405666b81ef4f13f30 (MD5) / Made available in DSpace on 2018-02-06T14:28:39Z (GMT). No. of bitstreams: 1
EDUARDO JORGE CALHEIROS JUNIOR - DISSERTACAO PPGEE 2014.pdf: 3431884 bytes, checksum: 5d6e954510b9e7405666b81ef4f13f30 (MD5)
Previous issue date: 2014-06 / As análises de adequabilidade de equipamentos são indispensáveis para permitir que as
empresas do setor elétrico conheçam as condições em que os mesmos operam,
garantindo assim o desempenho dos ativos da empresa e sua disponibilidade no Sistema
Interligado Nacional. Dentre os equipamentos analisados, destacam-se os
transformadores de potência pelo seu alto custo e a sua importância para o sistema
elétrico. Grande parte das falhas em transformadores de potência é de origem dielétrica,
relacionadas com a danificação da isolação dos condutores devido às deformações
mecânicas ocasionadas pelas altas correntes de curto-circuito passantes nos
enrolamentos, reduzindo a vida útil do equipamento. A partir destas considerações,
propôs-se avaliar os esforços eletromecânicos internos a alguns transformadores de
potência presentes no sistema CHESF, por intermédio de simulações computacionais,
quando da ocorrência de curto-circuito trifásico. A metodologia para as simulações
consistiu em selecionar os transformadores a serem analisados e coletar as informações
técnicas necessárias fornecidas pelos fabricantes. Posteriormente foram determinadas as
condições sistêmicas às quais os transformadores estariam submetidos e obtidos os
níveis de curto-circuito resultantes, para então efetuar as simulações propriamente ditas.
Os resultados das simulações computacionais mostraram os esforços eletromecânicos
estimados em quatro transformadores de potência em operação no sistema elétrico da
CHESF, resultantes do efeito dinâmico da corrente de curto-circuito trifásico que
percorrem os enrolamentos do transformador, considerando diferentes configurações
sistêmicas. As conclusões das análises dos resultados indicaram possíveis casos de
superações de limites admissíveis e revelou a importância dos aspectos construtivos dos
transformadores na sua capacidade de suportar os esforços mecânicos causados por
curtos-circuitos. / Analysis of suitability of equipment are indispensable for the electric sector companies
meet the conditions in which they operate, thus ensuring the performance of the
company's assets and its availability in the National Interconnected System (Sistema
Interligado Nacional). The power transformers are included among the analyzed
equipment due to its high cost and importance for the electrical system. Most faults in
power transformers is of dielectric origin, related to insulation damage due to
mechanical deformations, caused by the high short-circuit currents in the windings,
reducing the life of the equipment. Then, it was proposed to evaluate the internal
electromechanical efforts to some power transformers present in the CHESF system,
through computer simulations, in the event of a three-phase short circuit. The
methodology for the simulations consisted to select the transformers to parse and collect
the necessary technical information provided by the manufacturers. Later, certain
systemic conditions in which the transformers would be subjected were defined, it was
obtained the resulting short circuit levels and then was performed the simulations
themselves. The results of the computer simulations showed the electromechanical
efforts estimated at four power transformers in operation in the CHESF electrical
system, resulting from the dynamic effect of three-phase short-circuit current that run
through the windings of the transformer, considering different systemic configurations.
The conclusions of the analysis results indicated possible cases of overruns of
permissible limits and reveal the importance of the transformers constructive aspects in
their ability to withstand the mechanical stress caused by short circuits.
|
13 |
Simulace účinků zkratových proudů v rozvodnách VVN / Simulation of Effects of Short-circuit Currents in HV Switching StationsTománek, Miloslav January 2008 (has links)
This thesis is engaged in a theoretical calculation of short-circuit currents in electric power system in compliance with the norm ČSN 60909-0 and first of all with calculation of dynamical and thermal effects of short-circuit currents in HV switching stations in accordance with the norm ČSN 60865-1. Next the thesis is engaged in a production of programs for simulation of mechanical effects of short-circuit currents with respect to a dimensioning of constructional elements of switching station and afterwards in a practical simulation of selected parts of the real switching station type „H“ in Slavkov u Brna.
|
14 |
Charakterisierung von organischen Solarzellen an einem neu aufgebauten Laser-basierten DSR-MessplatzFey, Thomas 23 October 2015 (has links) (PDF)
Die Physikalisch-Technische Bundesanstalt (PTB) unterstützt vielfältig die Gesellschaft, Wirtschaft und Wissenschaft. Eine ihrer Kernkompetenzen als das nationale Metrologie-Institut der Bundesrepublik Deutschland ist die Messtechnik. In diesem Sinne kalibriert die Arbeitsgruppe „Solarzellen“ der PTB
i. d. R. den Kurzschlussstrom unter Standardtestbedingungen (I_STC) von Referenzsolarzellen. Der I_STC von Referenzsolarzellen ist in Photovoltaik-Kalibrierketten bei der Bestimmung der Bestrahlungsstärke von zentraler Bedeutung und fließt signifikant in die Berechnung der Wirkungsgrad von Solarzellen und Solarmodulen ein.
Um den I_STC einer Solarzelle mit geringster Messunsicherheit zu bestimmen, wurde die Differential Spectral Responsivity (DSR)-Methode verwendet. Sie basiert auf der Messung der differentiellen spektralen Empfindlichkeit bei unterschiedlichen Bestrahlungsstärken. Anhand dieser kann die absolute spektrale Empfindlichkeit s(λ) unter Standardtestbedingungen sowie der I_STC berechnet werden. Da jedoch die Umgebungsbedingungen meistens von den STC abweichen, reichen letztere nicht zum umfassenden Vergleich der Wirkungsgrade in der Praxis aus. Um Einflussfaktoren (Temperatur, Bestrahlungsstärke, Winkelabhängigkeit,...) genauer untersuchen zu können, wurde im Rahmen dieser Arbeit an der PTB ein neuer Laser-basierter DSR-Messplatz aufgebaut und charakterisiert.
Mit dem neuen Messplatz wurden c-Si Referenzsolarzellen, organische Solarzellen auf Basis kleiner Moleküle sowie Farbstoffsolarzellen umfassend untersucht. Unter anderem wurden die elektrischen Leistungsparameter einer organischen Solarzelle (aktive Schicht: DCV5T-Me:C60) mit denen einer c-Si Solarzelle verglichen. Es zeigt sich, dass der Wirkungsgrad der organischen Solarzelle mit zunehmender Bestrahlungsstärke sinkt und mit zunehmender Temperatur steigt, während die c-Si Solarzelle ein gegensätzliches Verhalten aufweist.
Darüber hinaus wurde u.a. die Winkelabhängigkeit der zweiten organischen Solarzelle (aktive Schicht: C60:DCV5T-Me(3,3)) untersucht und mit den Resultaten einer c-Si Solarzelle verglichen. Diese Untersuchungen haben ergeben, dass die Winkelabhängigkeit des Kurzschlussstroms der organischen Solarzelle im Vergleich zu einer c-Si Solarzelle insbesondere zwischen 20° < ϑ < 60° eine „Super-Kosinus-Anpassung“ aufweist.
Ergänzend wurde an der PTB im Rahmen dieser Arbeit ein mobiler Messplatz für Outdoormessungen aufgebaut. Mit diesem konnten die mittels Indoor-Untersuchungen erhaltenen spektralen Empfindlichkeiten mit Outdoor-Messungen verglichen werden. Des Weiteren wurden spektrale Charakterisierungen der Himmelshalbkugel durchgeführt und Methoden für Korrekturen von Sekundärkalibrierungen untersucht.
|
15 |
Measuring the efficiency and charge carrier mobility of organic solar cellsABUDULIMU, ABASI January 2012 (has links)
P3HT single layer, P3HT/PCBM bilayer and P3HT/PCBM inverted bilayer devices were produced by spin coating organic layers onto ITO patterned glass in air, and clamping it with an Au coated silicon wafer, as top electrode, at the end (Figure13). Normal and inverted bilayer devices were also fabricated with and without PEDOT:PSS. All devices were divided into two groups by changing concentration of P3HT solution. The first group of devices contained 1.0 wt. % P3HT solution (P3HT in dichlorobenzene); the second group 0.56wt %. Power conversion efficiency, short circuit current, open circuit voltage, fill factor and maximum extracted power were measured on all produced devices. In contrast, all devices with 1.0wt % P3HT concentration showed better result than the devices with 0.56wt %. The highest result was obtained for P3HT single layer devices in both cases with short circuit current 56uA/cm2, open circuit voltage 0.94mV, maximum power 11.4uW/cm2 and power conversion efficiency of 0.11%. Inverted bilayer devices performed better than the non-inverted one. The devices with PEDOT:PSS got slightly better performance than the non-PEDOT:PSS used one. Charge carrier mobility measurement was done for all fabricated devices with charge extraction by linearly increasing voltage (CELIV) and dark injected space charge limited current (DI-SCLC) methods. All devices showed same magnitude of charge carrier mobility 10-5 cm2/V.s, the highest value still belongs to P3HT single layer device. The charge carrier mobility in all devices observed by DI-SCLC technique is one order of magnitude higher than by CELIV technique. This may be due to DI-SCLC method`s restriction on ohmic contacts between material and electrode. / بۇ تەتقىقاتتا ئورگانىك ماتېرىيالدىن پايدىلنىپ ئۈچ خىل قۇياش ئىنىرگىيەلىك باتارىيە ئادەتتىكى ئۆي مۇھىتىدا ياساپ چىقىلدى. ئەڭ چوڭ توك كۈچى، ئەڭ يۇقىرى بېسىم، ئەڭ يۇقىرى قۇۋەت ۋە زەرەت يۆتكۈلۈش تېزلىكى ئۆلچەپ چىقىلدى ئۇيغۇر
|
16 |
Amélioration de la sélectivité des protections électriques des navires lors de l'alimentation à quai - Augmentation du courant de court-circuit / Improved the electrical protections selectivity on vessel’s grid during the shore supplying - Increase of short-circuit currentIon, Maricica-Mirela 14 January 2015 (has links)
Ce travail est relatif à l’augmentation du courant de court-circuit du réseau électriqueportuaire alimentant le navire. Ceci passe par une modélisation des réseaux des charges, dutransformateur et enfin convertisseurs concernés. Munis de cette compréhension du système,diverses solutions à base d’électronique de puissance ou d’éléments passifs ont étéinvestiguées, simulées et évaluées à l’aune des performances exigées. Pour l’augmentation ducourant de court-circuit, un transformateur spécialement créé pour cette application à deuxenroulements primaires est proposé. L’esprit de la solution est de modifier la configuration dutransformateur au moment de la détection du court-circuit en modifiant son rapport detransformation. Un banc de test temps réel hybride a été architecturé afin de tester cettesolution. Les essais sur le banc de test ont permis d’obtenir des résultats satisfaisants etencourageants qui corroborent la théorie. Pour finir des études complémentaires, sousdifférents scenarii, ont été menées en simulation hors ligne. / This work is about the short-circuit current increase, inside the harbor’s electrical networkthat supplies the electrical grid of each vessel docked in port. We analyze the system’srequirements, the load demands, the transformer and finally the modeling of the convertersinvolved. Armed with this understanding of the system, various solutions like powerelectronics devices or passive equipments were investigated, simulated and evaluated in termsof performance requirements. To increase the short-circuit current, we provide a noveltransformer with two primary windings. The purpose of this solution is to change theconfiguration of the transformer when the short circuit is detected by changing thetransformation ratio. A real-time hybrid test bench has been build in order to test the solution.The real-time tests have yielded good and encouraging results, supporting the theory. Finally,further studies under various scenarios were conducted in offline simulations.
|
17 |
Siūlės matmenų priklausomybės nuo trumpojo jungimo srovės stiprio tyrimas virinant glaistytaisiais elektrodais / Research of seam dimensional dependence on the short-circuit current in MMA welding processRimkus, Mindaugas 19 June 2013 (has links)
Darbe tiriami mažaanglio plieno S235J2 (LST EN 10025:2004) suvirintų siūlių pasikeitimai, plieną apvirinant skirtingais glaistytaisiais elektrodais ir suvirinimo režimais. Tyrimų metu buvo naudojami AV-23 ir AV-66 glaistytieji elektrodai bei keičiamas trumpojo jungimo srovės stipris. Nustatytas ryšys tarp metalo įvirinimo gylio, rumbelės aukščio, išlydytų lašų dydžio, išlydytų lašų kiekio, trumpojo jungimo trukmės ir trumpojo jungimo srovės dydžio. Gauti tyrimų rezultatai, nubraižyti priklausomybių grafikai ir pateiktos išvados. Darbą sudaro: įvadas, literatūros apžvalga, eksperimentuose naudojama įranga ir medžiagos, tyrimo metodika, tyrimų metu gauti rezultatai, grafikai, išvados, literatūra. Darbo apimtis: 83 p. teksto, 73 iliustr., 18 lent., 23 bibliografiniai šaltiniai. / In final work was analyzed the changes of seams properties of steel S235J2 (LST EN 10025:2004), produced by welding with different technology are discussed. Samples were welded by hand arc welding, using AV-23 and AV-66 welding electrodes. The welded seams were made by changing short-circuit current. The duration of weld depth, ridge height, metal drop size, metal drop frequency, short-circuit time and short-circuit current value are determinated. The results of the research are given in graphs, final conclusions are also written. Structure: the introduction, survey of the related literature, equipment and materials, description of the methodology, results of research, graphs of the results, conclutions, references. Thesis consist of: 83 p. text, 73 pictures, 18 tables, 23 bibliographical entries.
|
18 |
Amélioration de la sélectivité des protections électriques des navires lors de l'alimentation à quai - Augmentation du courant de court-circuit / Improved the electrical protections selectivity on vessel’s grid during the shore supplying - Increase of short-circuit currentIon, Maricica-Mirela 14 January 2015 (has links)
Ce travail est relatif à l’augmentation du courant de court-circuit du réseau électriqueportuaire alimentant le navire. Ceci passe par une modélisation des réseaux des charges, dutransformateur et enfin convertisseurs concernés. Munis de cette compréhension du système,diverses solutions à base d’électronique de puissance ou d’éléments passifs ont étéinvestiguées, simulées et évaluées à l’aune des performances exigées. Pour l’augmentation ducourant de court-circuit, un transformateur spécialement créé pour cette application à deuxenroulements primaires est proposé. L’esprit de la solution est de modifier la configuration dutransformateur au moment de la détection du court-circuit en modifiant son rapport detransformation. Un banc de test temps réel hybride a été architecturé afin de tester cettesolution. Les essais sur le banc de test ont permis d’obtenir des résultats satisfaisants etencourageants qui corroborent la théorie. Pour finir des études complémentaires, sousdifférents scenarii, ont été menées en simulation hors ligne. / This work is about the short-circuit current increase, inside the harbor’s electrical networkthat supplies the electrical grid of each vessel docked in port. We analyze the system’srequirements, the load demands, the transformer and finally the modeling of the convertersinvolved. Armed with this understanding of the system, various solutions like powerelectronics devices or passive equipments were investigated, simulated and evaluated in termsof performance requirements. To increase the short-circuit current, we provide a noveltransformer with two primary windings. The purpose of this solution is to change theconfiguration of the transformer when the short circuit is detected by changing thetransformation ratio. A real-time hybrid test bench has been build in order to test the solution.The real-time tests have yielded good and encouraging results, supporting the theory. Finally,further studies under various scenarios were conducted in offline simulations.
|
19 |
Selektivplan för högspänningsnät i södra Sverige : 130-, 20-, 10 kV / Selectivity plan for a high voltage power grid in southern Sweden : 130-, 20, 10 kVHansen, Simon, Karlsson, Fredrik January 2020 (has links)
I denna rapport utfördes en selektivplan på uppdrag av Kraftkällan Konsult för ett elnätsbolag i södra Sverige. Det visades att elnätet hade selektiva problem i samtliga stationer mellan reläskydden. Problemen har uppstått då karakteristiken i elnätet ändrats i samband med ombyggnationer. För att lösa problemen simulerades en modell av elnätet i PowerTools för att ta reda på kortslutningsströmmarna och nya selektivkurvor ritades efter dessa. Rekommendationer för högspänningssäkringar i nätstationer har också gjorts baserat på de nya kortslutningsströmmarna.
|
20 |
Optical Investigations of Cd Free Cu<sub>2</sub>ZnSnS<sub>4</sub> Solar CellsGangam, Srikanth January 2012 (has links)
No description available.
|
Page generated in 0.0716 seconds