• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Retention of resin restorations by means of enamel etching and by pins

Ayers, Alvin James, Jr., 1941- January 1971 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / An investigation was conducted into the effect of acid etching of the enamel and the use of pins on the retention of direct filling resins when used for restoration of fractured incisor teeth. The retention secured by these techniques as related to the cavity design also was studied. Four different cavity preparations were used. The retention of the resin in all four was compared when there was no pretreatment of the enamel, when the enamel was etched by 50 per cent phosphoric acid, and when pins were used for retention. Retention was assessed on the basis of resistance of the restoration to displacement by a lingual force. No significant difference was observed in retention as related to cavity design in the control specimens. In all four cavity preparations, acid etching of the enamel and the use of two retentive pins increased the resistance of the restorations to displacement. (However; when only one "L" shaped retentive pin was employed in Conjunction with a flat incisal preparation the force required to accomplish displacement was no greater than for controls.) The acid etch technique when employed with a cavity preparation that extended 1.7 mm. or more onto the lingual surface of the enamel generally offered a higher resistance to lingual force than double pin retained restorations. There was no significant difference between the resistance offered by a circumferential preparation when the resin was retained by either acid etching or by two pins. In the acid etch technique the enamel surface area and its distribution are important factors in retention.
122

Desenvolvimento e aplicação de partículas de fosfato de cálcio funcionalizadas com monômeros ácidos para remineralização dentária / Development and application of calcium phosphate particles functionalized with acidic monomers for dental remineralization

Chiari, Marina Damasceno e Souza 13 March 2019 (has links)
Os objetivos deste estudo foram: 1) sintetizar e caracterizar partículas de fosfato dicálcico dihidratado (DCPD) funcionalizadas com diferentes compostos orgânicos (ácido cítrico/AC, ácido acrílico/AA, fosfato de metacriloiloxietila/MOEP e dimetacrilato de dietilenoglicol/DEGDMA) e 2) avaliar o efeito da incorporação destas partículas sobre as propriedades físico-químicas e potencial remineralizador de compósitos experimentais. Na primeira fase do trabalho, partículas de DCPD foram sintetizadas pelo método da co-precipitação na presença de ácido cítrico, ácido acrílico, MOEP ou DEGDMA ou na ausência de funcionalizantes (não funcionalizadas/NF). As partículas foram caracterizadas por difração de raio x (DRX), análise elementar, densidade teórica, área superficial, difração de laser, microscopia eletrônica de varredura e potencial zeta. Na segunda etapa do trabalho, seis compósitos experimentais foram manipulados contendo dimetacrilato de glicidila bisfenol A (BisGMA)/dimetacrilato de trietileno glicol (TEGDMA) (1:1 em mols), fotoinciadores e 60 vol% de partículas, sendo essa proporção composta por partículas de vidro de bário silanizadas e 0 vol% (controle, sem DCPD) ou 20 vol% de partículas de DCPD. Os materiais foram avaliados quanto ao grau de conversão (GC), resistência à flexão biaxial (RFB) e módulo flexural (E) após 24 horas e 60 dias em água, liberação de íons e efeito protetor sobre esmalte adjacente à restaurações submetidas a um desafio cariogênico in vitro. Os resultados de GC, E, liberação de íons e ?KHNsuperficial/?KHNtransversal foram submetidos à análise de variância (ANOVA)/ teste de Tukey. Os resultados de RFB foram submetidos ao teste de Kruskal-Wallis/teste de Dunn. Em todos os casos, o nível de significância global foi de 5%. A formação de DCPD foi confirmada através do DRX. A análise elementar comprovou retenção de funcionalizante em níveis acima de 1,5% apenas para DCPD-DEGDMA, que também apresentaram redução na densidade devido à presença do monômero funcionalizante. Os valores de área superficial foram semelhantes para todas as partículas (22 - 30 m2/g). Partículas sintetizadas na presença de ácido cítrico apresentaram menor tamanho em relação às demais. Valores de potencial zeta variaram entre -0,9 e -14,2 mV. Todos os compósitos apresentaram GC semelhantes. Para RFB após 24 horas, apenas os materiais contendo DCPD-AA e DCPD-DEGDMA foram estatisticamente semelhantes ao controle, porém, após imersão prolongada, somente o material contendo DCPDDEGDMA manteve-se estatisticamente semelhante ao controle. Para E, após 24 horas, os compósitos contendo DCPD-NF, DCPD-MOEP, DCPD-DEGDMA ou DCPD-AA foram estatisticamente semelhantes e superiores ao controle. Após imersão, todos os compósitos apresentaram-se semelhantes ao controle, exceto DCPD-AA que apresentou menor módulo. O material contendo DCPD-AC apresentou maiores liberações iônicas do que aquele com DCPD-DEGDMA, o que possivelmente se refletiu no ?KHNsuperficial estatisticamente menor dos corpos de prova restaurados com compósito contendo DCPD-AC em comparação ao material contendo DCPD-DEGDMA. Para ?KHNtransversal, não houve interação estatisticamente significante entre os fatores. As maiores reduções foram observadas nas profundidades de 10 ?m e 30 ?m. Além disso, o esmalte ao redor do compósito contendo DCPD-AA apresentou maior redução em sua KHN do que o os materiais contendo DCPD-NF e do que o material controle. A síntese de DCPD foi realizada com êxito. Entretanto, apenas o ácido cítrico foi efetivo para redução do tamanho das partículas. DEGDMA foi o funcionalizante que apresentou maiores teores de retenção na superfície das partículas. Além disso, a funcionalização com DEGDMA favoreceu a interação entre DCPD e a matriz orgânica, o que foi evidenciado pelos maiores valores de resistência à flexão. Todavia, liberação de íons foi comprometida. Em 7 dias os compósitos contendo DCPD não tiveram um efeito protetor contra a desmineralização provocada pela ciclagem de pH. / The aims of this study were: 1) to synthesize and characterize dicalcium phosphate dihydrate (DCPD) particles functionalized with different organic agents (citric acid/CA, acrylic acid/AA, methacryloyloxyethyl phosphate/MOEP and diethylene glycol dimethacrylate/DEGDMA) and 2) evaluate the effect of the addition of these particles over physical-chemical properties and remineralization potential of experimental composites. In the first part of the study, DCPD particles were synthesized by a coprecipitation method in the presence of citric acid, acrylic acid, MOEP, DEGDMA or without functionalizing agent (non-functionalized/NF). Particles were characterized by X-ray diffraction (XRD), elemental analysis, density, surface area, laser diffraction, scanning electron microscopy (SEM) and zeta potential. In the second part, six resinbased materials were manipulated, containing in the organic phase bisphenol A glycerolate dimethacrylate (BisGMA)/triethylene glycol dimethacrylate (TEGDMA) (1:1 in mols), photoiniciators and 60 vol% of particles, composed by silanized barium glass and 0% (control: without DCPD) or 20 vol% of DCPD particles. Materials were evaluated for degree of conversion (DC), biaxial flexural strength (BFS) and flexural modulus (E) after 24 hours and 60 days of immersion in water, ion release and protective effect on adjacent enamel submitted to an in vitro cariogenic challenge. Data from DC, E, ion release ?KHNsurface/?KHNcross-sectional were subjected to analysis of variance (ANOVA)/Tukey test. Data from BFS were analyzed using Kruskal- Wallis/Dunn test. In all cases, the global significance level was 5%. DCPD formation was confirmed by XRD. Elemental analysis presented the retention of functionalizing agent retention at levels above 1.5% only for DCPD-DEGDMA, which also had reduction in density due to the presence of the functionalizing monomer. Surface area measurements were similar for all particles (22 - 30 m2/g). Particles synthesized in the presence of citric acid presented smaller size in relation to the others. Zeta potential values ranged from -0.9 to -14.2 mV. All composites presented similar DC. For BFS, after 24 hours, only the materials containing DCPD-AA and DCPDDEGDMA were statistically similar to the control, but after prolonged immersion only the material containing DCPD-DEGDMA remained statistically similar to the control. For E, after 24 hours, the composites containing DCPD-NF, DCPD-MOEP, DCPDDEGDMA or DCPD-AA were statistically similar and presented higher results than the control. After immersion, all composites were similar to the control, except for DCPD-AA, which had lower results. The material containing DCPD-CA presented higher ionic releases than the DCPD-DEGDMA, this possibly reflected on the lower results for ?KHNsurface for the specimens restored with the composite containing DCPD-CA in comparison to DCPD-DEGDMA material. For ?KHNcross-sectional, there was no statistically significant interaction for the factors. The highest reductions were observed at 10 ?m and 30 ?m dephts. Also, the enamel around the composite containing DCPD-AA presented higher reduction in KHN than the materials containing DCPD-NF and than the control. DCPD synthesis was successful. However, only citric acid was effective to reduce particle size. DEGDMA was the functionalizing agent that presented higher levels of retention in the particle surface. In addition, functionalization with DEGDMA favored the interaction between DCPD and the organic matrix, evidenced by the higher resuts of flexural strength. However ion release was compromised. In 7 days the DCPD-containing composites did not prersented a protective effect against the demineralization caused by the pH cycling.
123

Tratamento térmico pré e pós-cura de diferentes compósitos: análise térmica, reistência à flexão e grau de conversão / Heat treatment pre and post cured of differents composites: thermal analysis, flexural strength and degree of conversion

Gomes, Mauricio Neves 04 June 2008 (has links)
O objetivo deste estudo é realizar a caracterização térmica, resistência à flexão e o grau de conversão de um compósito nanoparticulado (Filtek Supreme XT: FT) e um microhíbrido (Esthet X: ET), cor A2, submetidos a diferentes tratamentos térmicos. Os grupos experimentais foram: G1: sem tratamento; G2: pré-aquecimento à 68°C com dispositivo Calset; G3: pós-aquecimento em forno MP-130, 10°C/min até 140°C e G4: pré e pós-aquecimento. Depois da fotoativação, foram realizadas análise termogravimétrica e calorimetria exploratória diferencial (DSC) para determinar a estabilidade térmica dos compósitos, temperatura de transição vítrea (Tg), pico de exotermia e calor liberado após fotoativação. O ensaio de resistência à flexão foi realizado 24h após armazenagem dos corpos de prova em água destilada a 37°C. A análise do grau de conversão foi realizada com espectrofotômetro FT-Raman. Análise de variância e teste de Tukey (p<0,05) demonstraram que os compósitos FT e ET têm 25,8% e 23,7% de matriz orgânica em peso respectivamente e estabilidade térmica até 200°C. O pico exotérmico do G2 (63,5°C) é maior do que G1 (60,9°C). Os grupos G3 e G4 não apresentaram pico exotérmico e calor liberado. A tg é de aproximadamente 160,5°C para o FT e de 161,4°C para o ET. A resistência à flexão (MPa) e grau de conversão(%) foram respectivamente: G1 (149,1; 60)=G2(152,5; 56,4) e G3 (170,5; 72,6)=G4 (178,2; 71,8) . O compósito ET apresenta maior grau de conversão que FT. À partir da caracterização térmica foi possível observar que o pré-aquecimento em condições não isotérmicas não promoveu maior conversão e resistência à flexão. O tratamento térmico deve ser realizado acima de 160°C. / The aim of this study was to perform the thermal characterization,flexural strength and degree of conversion of two composites, a nanofilled (Filtek Supreme XT: FT) and a microhybrid (Esthet X: ET), shade A2, submitted to different thermal treatments. Methods: The experimental groups were: G1: no treatment; G2: preheated at 68°C with Calset device; G3: post-heated in a MP-130 (EDG) oven, 10 °C/min up to reach 140°C for 20min and G4: pre and post-heated. After curing, thermogravimetric analysis and differential scanning calorimetry (DSC) were carried to determine thermal stability of the composites, glass transition temperature (Tg), exothermic peak and heat releasing after photoactivation. Three-point flexural test was performed after stored in water at 37oC for 24 hours. Degree of conversion was determined using a spectrophotometer FT-Raman. Analysis of variance and Tukey\'s test (P<0.05) showed that FT and ET composites have 25.8% and 23.7% of organic matrix in weight respectively and thermal stability at 200°C. The G2 group release more heat (9.9J/g) than G1 (7.3J/g). Exothermic peak of G2 group (63.5°C) is higher than G1 (60.9°C). G3 and G4 groups did not show exothermic peak and heat releasing. ET composite of G2 group presented the highest exothermic peak (65.2°C) of all groups. The Tg is nearly 160.5°C to FT and 161.4°C to ET. Flexural strength (MPa) and degree of conversion (%) were respectively: G1(149.1; 60) = G2(152.5; 56.4) and G3 (170.5; 72.6) = G4 (178,2; 71,8). ET composite presented higher conversion values than FT. Pre-heating at non-isothermal conditions does not promote higher conversion and flexural strength. Heat treatment after cure can be carried through 160°C.
124

Fatores relacionados ao desenvolvimento de tensões de polimerização em compósitos experimentais contendo BisGMA, TEGDMA e BisEMA / Factors related to polymerization stress development in experimental composites using BisGMA, TEGDMA and BisEMA

Gonçalves, Flavia 12 June 2007 (has links)
Objetivo: avaliar a influência do conteúdo de BisGMA, TEGDMA e BisEMA sobre tensão de polimerização (spol), grau de conversão (GC), contração volumétrica (CV), módulo de elasticidade (E), escoamento (ES), taxa máxima de reação (RPmax) e incremento máximo de tensão (RSmax) e verificar as possíveis relações de dependência entre a tensão de polimerização e as demais variáveis. Material e métodos: Foram estudadas nove misturas, todas contendo 40% em peso de sílica coloidal, variando a concentração molar de BisGMA (33, 50 ou 66%) e o tipo de comonômero (TEGDMA, BisEMA ou ambos em partes iguais). spol foi determinada pela inserção do compósito (h=1mm) entre bastões de acrílico (r=3mm) fixados às garras de uma máquina universal de ensaios e dividindo-se a máxima força de contração registrada pela secção transversal dos bastões. CV foi mensurada em dilatômetro de mercúrio. E foi obtido através do teste de flexão em três pontos. Fragmentos de espécimes de flexão de cada grupo foram utilizados para análise do GC por FTRaman. O ES foi obtido pela aplicação de uma carga de 20N por 60s sobre o compósito não-polimerizado. RPmax foi determinada por calorimetria exploratória diferencial (DSC). RSmax foi calculado pela diferença entre dois valores de spol consecutivos. Os dados foram submetidos a ANOVA de dois fatores, teste de Tukey (a=0,05%) e análises de regressão. Resultados: A interação entre os fatores foi estatisticamente significante para todas as variáveis avaliadas (p<0,01), com exceção de GC onde apenas os fatores principais foram significantes (p<0,001). Em geral, composições com maior concentração de BisGMA e com o co-monômero BisEMA apresentaram menor GC e ES, o que se refletiu em menores valores para spol, CV e E. RPmax foi semelhante em todos os grupos, com exceção do compósito com 66%TEGDMA, que apresentou valor estatisticamente menor. Entretanto,. esse grupo apresentou o maior valor de RSmax. As análises de regressão evidenciaram forte relação direta de dependência da spol com GC (R2=0,830), ES (R2=0,896), CV (R2=0,690) e RSmax (R2=0,900). A correlação com o E foi fraca (R2=0,404) e com RPmax foi negativa (R2=0,667). Conclusões: Dentre as formulações avaliadas, compósitos contendo BisEMA e aqueles com maiores concentrações de BisGMA apresentaram, em geral, menor spol, GC, CV, ES e E. RPmax foi pouco afetada pela composição da matriz orgânica. spol mostrou maior relação de dependência com os fatores GC, CV e ES. / Objective: To evaluate the influence of BisGMA, TEGDMA and TEGDMA content on polymerization stress (spol), degree of conversion (DC), volumetric shrinkage (VS), elastic modulus (E), flow, maximum polymerization rate (RPmax) and maximum stress rate (RSmax) and to establish the correlation between polymerization stress and the other variables. Materials and Methods: Nine resin mixtures were studied, varying the BisGMA molar concentration (33, 50 or 66%) and the co-monomer content (TEGDMA, BisEMA or both in equal parts). All blends received 40 wt % of colloidal silica. spol was determined by inserting the composite (h=1mm) between acrylic rods (r=3mm) fixed on the opposite ends of a universal testing machine, and dividing the maximum contraction force by the rods? cross section. VS was measured by mercury dilatometry. E was obtained by three-point bending test. Fragments of flexural specimens were used to analyze DC by FT-Raman. Flow was obtained applying load of 20N for 60s on the uncured composite. RPmax was determined by differential scanning calorimetry (DSC). RSmax was calculated by the difference between two consecutives spol values. Data were submitted to two-way ANOVA, Tukey´s test (a=0.05%) and regression analyses. Results: The interactions between factors were significant for all variables (p<0.01), except for DC, where only the main factors were significant (p<0.001). In general, composites with higher BisGMA concentration and those containing BisEMA showed lower DC and flow, which resulted in lower values of spol, VS and E. RPmax was similar for all groups, except for the 66%TEGDMA composite, which showed a statistically lower value. However, this group showed the highest value of RSmax. The regression analyses evidenced a strong direct dependence of spol to DC (R2=0.830), flow (R2=0.896), VS (R2=0.690) and RSmax (R2=0.900). The correlation with E was weak (R2=0.404) and with RPmax was negative (R2=0.667). Conclusion: For the monomer mixtures studied, composites with BisEMA and those with higher BisGMA concentration showed, in general, lower spol, DC, VS, flow and E. RPmax was almost insensitive to the organic matrix composition. spol showed stronger dependence with DC, VS and flow.
125

Influência de características de equipamentos fotoativadores e tempos de fotoativação na polimerização de resinas compostas bulk fill / Influence of characteristics of light curing units and photoactivation times on the polymerization of bulk fill composite resins

Shimokawa, Carlos Alberto Kenji 12 June 2017 (has links)
Os equipamentos fotoativadores apresentam diferentes características e elas podem influenciar na polimerização de restaurações em resina composta. O objetivo desse estudo foi avaliar as características de quatro equipamentos fotoativadores e verificar sua influência na polimerização de duas resinas compostas bulk fill. Os equipamentos fotoativadores Bluephase 20i (Ivoclar Vivadent), Celalux 3 (Voco), Elipar DeepCure-S (3M ESPE) e Valo Grand (Ultradent) foram avaliados quanto ao diâmetro da ponteira, à potência, à irradiância, ao espectro de emissão e ao perfil do feixe de luz, e utilizados na fotoativação das resinas compostas Filtek Bulk Fill Posterior Restorative - A2 (3M ESPE) e Tetric EvoCeram Bulk Fill - IVA (Ivoclar Vivadent). Matrizes de Delrin® brancas foram utilizadas para confecção de espécimes de 12 mm de diâmetro e 4 mm de espessura, sendo a dureza nas superfícies de topo e fundo desses espécimes avaliadas com 97 endentações por superfície, no centro e em todas as direções. Uma matriz de dente foi confeccionada para a avaliação da dureza transversal de restaurações de 12 mm de largura e 4 mm de profundidade, sendo feitas endentações no centro e nas regiões mesial e distal (4,5 mm do centro), a cada 0,5 mm de profundidade. Após os ensaios de microdureza, os espécimes foram imersos em Tetrahidrofurano por 24 horas. A transmissão de luz através dos espécimes também foi avaliada. Os dados obtidos foram analisados estatisticamente com testes de ANOVA e Tukey, com nível de significância de 5%, e teste t. Os valores de dureza mensurados nos espécimes confeccionados com auxilio das matrizes de Delrin® mostram que os fatores resina composta e superfície mensurada exercem influência sobre os resultados (p<0,05). A interação entre o fator equipamento fotoativador e a região das endentações também influenciou os resultados, sendo que o uso do Valo Grand não resultou em diferenças estatisticamente significantes entre os valores mensurados no centro e na região externa (p>=0,05). Quando o Celalux 3 foi utilizado, houve diferença estatisticamente significante entre os valores obtidos nas regiões central e externa (p<0,05). Os resultados de dureza mensurados nos espécimes confeccionados com a matriz feita com uso de dente humano mostraram diferenças estatisticamente significantes entre 10 e 20 segundos de fotoativação (p<0,05). O fator resina composta também exerceu influência sobre os resultados. Houve diferença estatisticamente significante entre o centro e as regiões mesial e distal quando todos os equipamentos fotoativadores foram utilizados (p<0,05). Também foi observada diferença estatisticamente significante entre os valores obtidos nas caixas mesial e distal dos espécimes (p<0,05). Os resultados de transmissão de luz mostraram que pouca luz violeta chega ao fundo dos espécimes e a posição e o tamanho da ponteira dos equipamentos fotoativadores influenciam na irradiância da luz que chega no fundo das caixas proximais de restaurações MOD. Os equipamentos fotoativadores apresentaram diferenças, sendo que elas, associadas à diferentes protocolos de fotoativação, influenciaram na dureza de restaurações confeccionadas com resinas compostas bulk fill. / Light curing units can present different characteristics and they can influence the polymerization of composite resin restorations. The aim of this study was to analyze the characteristics of four light curing units and verify their influence on the polymerization of two bulk fill composite resins. The light curing units Bluephase 20i (Ivoclar Vivadent), Celalux 3 (Voco), Elipar DeepCure-S (3M ESPE) and Valo Grand (Ultradent) were analyzed regarding their tip diameter, radiant power, irradiance, emission spectrum and light beam profile, and used for the photoactivation of the composite resins Filtek Bulk Fill Posterior Restorative - A2 (3M ESPE) and Tetric EvoCeram Bulk Fill - IVA (Ivoclar Vivadent). White Delrin® matrices were used for the confection of 12 mm diameter and 4 mm depth specimens, being their hardness measured at the top and bottom surfaces, with 97 indents per surface, at the center and all the directions. One matrix, made using human tooth, was used for the confection of 12mm wide and 4 mm depth restorations, in which the transversal hardness was measured. Indents were made at the center and the mesial and distal regions (4,5 mm from the center) of the restorations, at every 0,5 mm in depth. After the microhardness tests, the specimens were immersed in Tetrahydrofuran for 24 hours. The light transmission through the specimens was also analyzed. The obtained data was statistically analyzed with the ANOVA and Tukey tests, with a 5% significance level, and t test. The hardness values measured at the specimen made with the Delrin® matrices showed that the factors composite resin and surface influenced the results (p<0,05). The interaction between the light curing unit and the region of the indents also influenced the results, when the Valo Grand was used, there was no statistically significant difference between center and the external regions (p>=0,05). When the Celalux 3 was used, there was a statistically significant difference between the central and external regions (p<0,05). The hardness results obtained with the specimen made using the matrix of human tooth showed statistically significant differences between the 10 and 20 second photoactivation times (p<0,05). The factor composite resin also influenced the results. There was a statistically significant difference between the center and the mesial and distal regions when all the light curing units were used (p<0,05). There was also a statistically significant difference between the values measured on the mesial and distal boxes of the specimen (p<0,05). The light transmission results showed that little violet light reaches the bottom of the specimens and the position and the light curing unit\'s tip diameters influence the irradiance of light that reaches the bottom of the proximal boxes of MOD restorations. The light curing units showed different characteristics and they, associated to different photoativation protocols, influence the hardness of bulk fill composite resin restorations.
126

Efeito da configuração cavitária, técnica de inserção e modo de ativação na infiltração marginal de restaurações de resina composta.

Esmeral Leal, Luisa Isabel 21 February 2001 (has links)
A configuração cavitária e o modo de polimerização das resinas compostas têm sido apontados como fatores que podem afetar a interface adesiva. Nesta pesquisa, investigamos a microinfiltração em cavidades de Classe V, e para tanto foram realizadas cavidades de 6 mm (C=6) ou 3 mm (C=3) de comprimento, 3 mm de largura e 1,5 mm de profundidade, na face vestibular das raízes de incisivos bovinos. As cavidades, foram condicionadas com ácido fosfórico a 37%, em gel (3M), foram tratadas com duas camadas de adesivo Single Bond (3M) e restauradas com resina composta Z-100 (3M) ou Bisfil-2B (Bisco), utilizando a técnica incremental ou a técnica de um único incremento. Os dentes restaurados foram armazenados em água destilada a 37ºC durante 48 horas, protegidos com esmalte de unhas até 1 mm aquém das margens da restauração, imersos em fucsina básica a 0,5% durante 4 horas e lavados em água corrente por uma hora. As restaurações foram secionadas em seu longo eixo e as seções foram digitalizadas em um scanner para determinar o grau de infiltração marginal em milímetros e analisá-las através de um programa de computação para análise de imagem. A seção com maior extensão de infiltração foi escolhida para análise dos resultados. O tamanho da amostra foi N=24 e os resultados foram descritos em milímetros de infiltração. A análise estatística foi realizada pelo teste de ANOVA e mostrou que não houve influência ou interação estatisticamente significante entre os fatores (p. > 0,05). Todas as técnicas mostraram algum grau de infiltração e não se identificaram diferenças estatisticamente significantes entre as paredes gengival e apical (p > 0.05). A microinfiltração não foi afetada pela configuração cavitária ou pelo modo de polimerização das resinas. / Cavity configuration and mode of cure have been reported to affect bonding of resin to cavity walls. This study investigated the microleakage in class V resin restoration. Cavities measuring either 6 mm (C 6) or 3 mm (C 3) long by 3 mm wide and 1.5 mm deep were cut in the roots of bovine teeth. The cavities were bonded with Single Bond and restored with either Z-100 or Bisfil-2B by using either bulk or incremental filling techniques. The restoration teeth were stored for 48 hrs in water at 37ºC, covered with nail varnish up to 1mm from the margins and immersed in 0.5% fucsin for 4 hrs. The restorations were sliced along the long axis and the degree of leakage (in mm) determined by image analysis. The highest leakage for tooth was used for the calculations (N=24).Two-way ANOVA showed that there was no significant influence or interaction between the factors (p.0.05). All filling techniques showed some degree of leakage and there was no statistically significant difference between gingival and apical walls (p>0.05). microleakage was not affected by either configuration or mode of cure in this study.
127

Efeito do pino intra-radicular e da presença de férula na resistência de dentes tratados endodonticamente / Effect of intraradicular post and the presence of ferrule on the resistance of endodontically treated teeth

Pereira, Jefferson Ricardo 06 August 2007 (has links)
O objetivo deste trabalho foi avaliar a resistência à fratura de dentes tratados endodonticamente restaurados com diferentes pinos intra-radiculares, sem pinos intra-radiculares e diferentes quantidades de remanescente dentário coronal. Para a realização deste trabalho, foram selecionados 60 caninos humanos recentemente extraídos. Todos os dentes foram tratados endodonticamente e divididos aleatoriamente em 6 grupos de 10 dentes cada. Grupos NMF0 e NMF3 (grupos controle): dentes restaurados com núcleos metálicos fundidos com 0mm (sem férula) e 3mm de estrutura coronal, respectivamente; Grupos PF0 e PF3: dentes restaurados com pinos pré-fabricados (Screw Post) com 0mm e 3mm de estrutura coronal, respectivamente; e Grupos RC0 e RC3: dentes restaurados com resina composta com 0mm e 3mm de estrutura coronal, respectivamente. Os grupos restaurados com pinos pré-fabricados ou resina composta receberam núcleos de preenchimento de resina composta (Z250) localizados acima das diferentes alturas de remanescente coronal. Todos os dentes foram restaurados com coroas totais metálicas. A resistência à fratura (kgf) foi medida em uma máquina de ensaio universal à 45 graus ao longo eixo do dente até a falha do conjunto. Os dados foram analisados através da Análise de Variância (ANOVA) a dois critérios, e o teste de Tukey (\'alfa\'=.05). A ANOVA (\'alfa\'=.05) mostrou haver diferenças estatisticamente significativas entre os tipos de pinos (P<.000), entre as diferentes alturas de remanescente coronal (P<.000) e mostrou uma significativa inter-relação entre os tipos de pinos e remanescente coronal (P<.000). No entanto, quando as forças médias de resistência à fratura foram comparadas (grupo NMF0 - 820.20N, grupo NMF3 - 1179.12N, grupo PF0 - 561.05N, grupo PF3 - 906.79N, grupo RC0 - 297.84N e grupo RC3 - 1135.15N) não foram detectadas diferenças significativas entre os 3 grupos com 3mm de remanescente coronal (grupos NMF3, RC3 e PF3). Os resultados deste trabalho mostraram que a presença de férula providencia um significativo aumento da resistência à fratura de dentes tratados endodonticamente restaurados com núcleos metálicos fundidos, pinos pré-fabricados ou resina composta, e mostraram que a presença de um pino intra-radicular para restaurar dentes tratados endodonticamente é necessária quando não existe remanescente dentário coronal (efeito férula). / The aim of this study was to investigated the fracture resistance of endodontically-treated teeth restored with different posts, without post and variable ferrule heights. Sixty freshly-extracted canines were endodontically treated. They were randomly divided into groups of 10 teeth and were prepared according to 6 experimental protocols. CP0 group and CP3 group (control groups): teeth restored with custom cast post-and-core with 0 mm (no ferrule) and 3 mm of coronal structure, respectively; PF0 group and PF3 group: teeth restored with prefabricated post (Screw-Post) with 0 mm and 3 mm of coronal structure, respectively; and CR0 group and CR3 group: teeth restored with composite resin with 0 mm and 3mm of coronal structure, respectively. The groups restored with prefabricated post or composite resin received composite resin core (Z250) located superior to the different tooth structure heights. All teeth were restored with complete metal crowns. The fracture resistance (N) was measured in a universal testing machine at 45 degrees to the long-axis of the tooth until failure. Data were analyzed by 2-way analysis of variance and Tukey test (\'alpha\'=.05). The 2-way analysis of variance (\'alpha\'=.05) showed difference statistically significant among the types of post (P<.000), between the different coronal dentin heights (P<.000) and showed a highly significant interaction among type of post and coronal remaining (P<.000). However, when the means fracture forces for the groups were compared (CP0 group - 820.20N, CP3 group - 1179.12N, PF0 group - 561.05N, PF3 group - 906.79N, CR0 group - 297.84N, and CR3 group - 1135.15N) no significant differences could be detected among the three groups with 3 mm of coronal remaining (CP3, CR3 and PF3 groups). The results of this study showed that larger ferrule designs in crowns provided a significantly higher fracture resistance of endodontically-treated teeth restored with custom cast post and core, prefabricated posts, or composite resin and showed that the presence of the post to restore endodontically-treated teeth is necessary when there is not a crown ferrule effect.
128

Influência da distância de fotoativação na microdureza, sorção, solubilidade e estabilidade de cor de uma resina composta microhíbrida / Influence of light curing tip distance on microhardness, water sorption, solubility and color stability of a microhybrid resin composite

D'Alpino, Nádia da Rocha Svizero 04 September 2009 (has links)
O objetivo deste trabalho foi avaliar a influência da distância de fotoativação na microdureza Knoop, na sorção, na solubilidade e na estabilidade de cor de uma resina composta microhíbrida (Filtek Z250 3M ESPE). Os corpos-de-prova foram confeccionados em uma matriz de teflon (6,0mm x 2,5mm espessura) e fotoativados por 20s variando-se a distância entre a ponta do aparelho fotoativador e a superfície da resina composta: G1- 0mm (controle), G2- 5mm, G3- 10mm, G4- 15mm. Em seguida, os espécimes foram armazenados secos em recipientes escuros por 24h. O teste de microdureza Knoop (100g por 15s) foi realizado nas superfícies topo e base dos espécimes após 24h, 6 meses e 1 ano. Para o teste de sorção e solubilidade, os espécimes foram colocados no dessecador para obtenção da massa inicial, armazenados em água até uma massa constante e novamente submetidos ao processo de dessecamento até a obtenção de uma massa constante. Para o teste de estabilidade de cor, após a medida de cor inicial realizada com um espectrofotômetro, os espécimes foram diariamente submetidos a dois ciclos de 10 minutos de imersão no suco de uva, permanecendo o restante do tempo em água. Os espécimes do grupo controle ficaram imersos em água ao longo de todo o período experimental (28 dias). A cor foi mensurada semanalmente. Os dados de microdureza e estabilidade de cor foram submetidos aos testes estatísticos ANOVA a 3 critérios/ Tukey e os de sorção e solubilidade a ANOVA um critério/ Tukey (=0,05). Após 24h, o G4 apresentou valores significativamente menores de dureza comparados ao G1 na superfície topo, enquanto que na base, a dureza do G2, G3 e G4 foi estatisticamente menor que G1. Ambas as superfícies avaliadas mostraram redução nos valores de microdureza após 6 meses e 1 ano. G3 e G4 apresentaram maior sorção de água e G4 maior solubilidade, comparado a G1. A estabilidade de cor do compósito foi influenciada pelo tempo, meio de imersão e pela distância de fotoativação. O suco de uva causou alteração estatisticamente significante na cor do compósito (E) em função do tempo de armazenamento e da distância de fotoativação (G4). Conclui-se que quanto maior a distância da fonte de luz, menores os valores de microdureza, maior a sorção e solubilidade e menor a estabilidade de cor do compósito avaliado. / The purpose of this in vitro study was to evaluate the influence of light curing tip distance on microhardness, sorption, solubility and color stability of a microhybrid resin composite (Filtek Z250-3M ESPE). Specimen discs (6mm x 2,5mm) were irradiated for 20s with a continuous output at 640mW/cm2, according to different curing tip distances: G1-0mm (control), G2-5mm, G3-10mm and G4-15mm. Specimens were stored dry in a lightproof container for 24h. Knoop hardness measurements were obtained on the top and bottom surfaces of the samples (100g, 15s) after 24h, 6 and 12 months. To evaluate sorption and solubility, specimens were desiccated to be weighed and then stored in distilled water until a constant mass was obtained. The reconditioning in the desiccators was also done until a constant mass. To evaluate de color stability of the resin composite, the first color measurements were made and then specimens were immersed in a grape juice twice a day for 10 minutes, during 28 days. Control groups were immersed in distilled water for the same period of time. Color measurements were made weekly using a spectrophotometer. Data from microhardness/ color stability and from water sorption/ solubility were submitted to three-way ANOVA/Tukey and one-way ANOVA /Tukey tests, respectively (p<0,05). For top and bottom surfaces, there were statistical differences among the curing tip distances after 24h. Although, the microhardness values were lower for both surfaces after 6 and 12 months. G3 and G4 showed significant higher water sorption and G4 higher solubility when compared to G1. Grape juice showed significant color change of the resin composite as a function of time and curing tip distance (G4). It may be concluded that the distance between light curing tip and resin composite surface decreases microhardness and color stability, and increases sorption and solubility of the evaluated resin composite.
129

"Estudo da interface adesiva em restaurações que combinam resinas com diferentes módulos de elasticidade" / Evaluation of the adhesive interface of restorations combining composite resins with different elastic modulus

Kenshima, Silvia 11 December 2001 (has links)
O objetivo deste estudo foi o de avaliar uma técnica teste para inserção de resinas compostas combinadas e duas técnicas convencionais, quanto à qualidade da interface adesiva, em restaurações classe V realizadas em dentes bovi nos. Foram utilizadas as resinas compostas (Z-250 e Durafill VS) com o sistema adesivo (Single Bond) em 30 preparos confeccionados nas superfícies vestibulares dos dentes (fator C= 3). Portanto, foram analisadas seis técnicas r estauradoras com 5 repetições: incremental vertical (Z-v e D-v), incremental oblíqua (Z-o e D-o), e teste [Z-t e D-t (forramento das paredes cavitárias com uma resina e preenchimento com a outra)]. Os espécimes foram armazenado s por 24 h em água a '37 GRAUS'C e secionados no sentido V-L, originando 4 superfícies para obtenção de dados por espécime, as quais foram condicionadas (ácido fosfórico a 37%, por 3s) e coradas (azul de metileno a 0,5%, por 2s ). Para mensurar o comprimento (c) e a largura (l) dos gaps, a interface adesiva foi examinada por microscopia ótica (400X). A largura média ('mü'm) dos gaps foi calculada através da equação lm = 'sigma' ('c IND. n' x 'l IND. n ') / 'sigma' 'c IND. n'. Os resultados obtidos pelo tratamento estatístico dos dados (ANOVA para Medidas Repetidas) mostraram que somente a Técnica e a Superfície de leitura foram significativas (p < 0,05). Concluiu-se com base n estes resultados que a técnica teste apresentou qualidade de interface inferior, ou seja, gaps mais largos e que, a largura média dos gaps relativa à seção central foi maior que a das superfícies externas medidas / The objective of this study was to evaluate the quality of the adhesive interface of an experimental placement technique, which combines different composite resins, and two conventional techniques used in class V restorations i n bovine teeth. Two composite resins were applied in this study (Z-250 and Durafill VS) with the adhesive system (Single Bond) in 30 cavity preparations made on the labial surface of the teeth (C-factor = 3). So, six restorativ e techniques were applied with 5 samples each: incremental vertical (Z-v e D-v), incremental oblique (Z-o e D-o), and experimental [Z-e and D-e (lining the cavity walls with one of the resins and bulk filling with the other)]. After 24-hour-storage in water (37° C), each specimen was sectioned (LB) generating 4 surfaces for gap assessment that were previously acid etched (phosphoric acid 37% for 3s) and stained (metilene blue 0.5% for 2s). The adhesi ve interface was examined by optic microscopy at 400X and both length (l) and width (w) of gaps were measured (´mü´m). The mean gap widths were calculated by the equation w = ´sigma´ (´c IND.n´ x ´l IND.n´) / ´sigma´ ´c IND. n´ . The results obtained from the data's statistical analysis (ANOVA for Repeated Measurements) showed that only Technique and Surface were significant (p < 0,05). Based in this results it was concluded that the experimental techni que showed the worst interface quality, which means that gap widths were larger and that the gap width means of the central section were higher than the measured external ones
130

Avaliação da interface de adesão à dentina humana de um sistema restaurador adesivo à base de silorano, em cavidades de Classe I, analisados por teste de microtração e microscopia óptica / Evaluation of the interface of a silorane based restorative system to dentin of Class I cavities by microtensile bond strength test and optical microscopy

Espinoza, Carlos Andrés Villavicencio 24 May 2013 (has links)
Este estudo teve como objetivo a análise da interface de adesão à dentina humana, de um sistema restaurador adesivo à base de silorano. Foram confeccionadas cavidades com 4mm X 3mm X 5mm em 40 molares humanos extraídos divididos em 4 grupos aleatoriamente: Grupos SB e SB-6m: sistema adesivo (Adper&#x2122; Single Bond) + resina composta (Filtek Z250); Grupos P90 e P90-6m: sistema adesivo (P90 System Adhesive) + resina composta (Filtek P90&#x2122;). Em todos os grupos, as restaurações foram inseridas em 4 incrementos oblíquos. Após a restauração, os dentes foram seccionados em fatias de 0,8mm de espessura em uma máquina de cortes com um disco de diamante. Uma fatia de cada dente foi separada aleatoriamente para análise em microscópio óptico para verificação de fendas na interface adesiva. As demais fatias foram seccionadas em palitos (0,8mm X 0,8mm) para os testes de microtração em uma máquina de ensaios universal EMIC. Os e dos grupos SB e P90 permaneceram em água deionizada em estufa a 370C por 24 horas e os grupos SB-6m e P90-6m permaneceram em água deionizada em estufa a 370C por um período de 6 meses. Os resultados de resistência de união foram submetidos à análise de variância a 2 critérios ANOVA e a presença de fendas internas foi analisada pelo testeChi-quadrado. Houve diferença estatisticamente significante na resistência de união entre os materiais (p>0,05) e tempo de armazenagem. Quanto à presença de fendas internas, foi evidenciada sua presença em todos os grupos, sem diferença etatisticamente significante entre eles (p>0,05). Conclui-se que não houve diferença entre os sistemas restauradores á base de Bis-GMA e de silorano os 2 períodos avaliados (24h e 6 meses). / This study aimed to analyse the adhesive interface to human dentin of a silorane based adhesive system. Cavities were fabricated with 4.0 mm X 3mm X 5mm in 40 extracted human molars randomly divided into 4 groups: Groups SB and SB-6m: adhesive system (Adper&#x2122; Single Bond) + composite (Filtek Z250); Groups P90 and P90- 6m: adhesive system (P90 System Adhesive) + composite (Filtek&#x2122; P90). In all groups, the restorations were inserted in 4 oblique increments. After 24 hours, teeth were sectioned buccolingually into 0.8mm slices with diamond saw. One slice of each tooth was randomly separated for microscope analysis. The other slices were sectioned into 0.8mm X0.8mm sticks for microtensile tests in a universal testing machine EMIC. Sticks of groups SB and P90 remained in deionized water at 370C C for 24 hours and sticks of groups SB-6m and P90-6m remained in deionized water at 370C for a period of six months. After storage period . The results of bond strength were analysed by Two-way ANOVA and the presence of internal gaps was analyzed by chi-square test. There was no significant difference in bond strength between materials (p> 0.05) and storage time. Regarding the presence of internal rifts, their presence was evident in all groups, with no statistically significant difference between them (p> .05).

Page generated in 0.1079 seconds