• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Influence of the energy density on the physical properties and bond strength of two restorative systems = Influência de densidade de energia nas propriedades físicas e na resistência de união de dois sistemas restauradores / Influência da densidade de energia nas propriedades físicas e na resistência de união de dois sistemas restauradores

Catelan, Anderson, 1983- 10 November 2012 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T13:04:27Z (GMT). No. of bitstreams: 1 Catelan_Anderson_D.pdf: 1687894 bytes, checksum: a9125b094311555bd99bde3ee3a23b10 (MD5) Previous issue date: 2012 / Resumo: O propósito deste estudo foi avaliar a influência de diferentes densidades de energia nas propriedades físicas e na resistência de união de sistemas restauradores a base de metacrilato [Clearfil SE Bond (Kuraray) + FiltekZ250 (3M ESPE)] e silorano [sistema Filtek P90 (3M ESPE)], foto ativados com LED de segunda geração de acordo com os grupos experimentais. Espécimes foram confeccionados para o teste de grau de conversão (GC); os espectros de absorção foram obtidos por meio da espectroscopia FT-IR e FT-Raman para os adesivos (n = 10) e compósitos (n = 5), respectivamente. A dureza Knoop (DK) foi avaliada no topo e base dos compósitos (n = 10). Após 24 h de imersão em etanol absoluto, nova leitura de DK foi realizada para obtenção da plastificação (P) pela redução percentual da dureza. Os testes de sorção de água (SA) e solubilidade(S) dos adesivos (n = 5) e compósitos (n = 5) foram realizados de acordo com a norma 4049:2009, exceto para o tamanho dos espécimes e protocolo de fotoativação. Para os testes de resistência de união (n = 7) e nanoindentação (n =3), cavidades Classe II foram realizadas nas proximais de molares humanos, as quais foram restauradas com os sistemas restauradores avaliados. O teste demicrotração foi realizado em uma máquina de ensaio universal sob velocidade constante de 0,5 mm/min. Na técnica da nanoindentação foram mensurados a nano dureza (ND) e o módulo de elasticidade reduzido (Er) da dentina, camada híbrida, adesivo e compósito. Os dados obtidos foram submetidos à análise estatística (alfa = 0,05). Para os adesivos a maior densidade de energia melhorou somente o GC (p < 0,05); o "primer" da P90 exibiu maior GC, SA e S comparado ao "Bond" do Clearfil e P90 (p < 0,05). O compósito metacrilato apresentou maior GC, DK, P e SA (p < 0,05) do que o silorano. Não houve diferença na S das resinas compostas (p > 0,05). Geralmente a superfície de topo mostrou maior GCe DK do que a base (p < 0,05). O sistema restaurador a base de metacrilato, bem como o aumento da densidade de energia mostraram maior resistência de união (p < 0,05), sem diferença entre 24 h e 6 meses (p > 0,05). Os valores de ND e Erdos materiais a base de metacrilato foram maiores do que os do silorano (p <0,05). A maior densidade de energia não melhorou a ND e Er dos materiais (p >0,05). O envelhecimento diminuiu a maioria das propriedades nanomecânicas dos componentes da interface dente-restauração (p < 0,05), exceto a ND e Erdo compósito e Er do adesivo (p > 0,05). Assim, pode-se concluir que as propriedades físicas e a resistência de união foram material-dependente; a maior densidade de energia melhorou a resistência de união, mas não influenciou, em geral, as propriedades físicas e nano mecânicas; e o envelhecimento diminuiu a maioria das nano propriedades dos componentes da interface dente-restauração, mas não afetou a resistência de união das restaurações / Abstract: The purpose of this study was to evaluate the influence of different energy densities on the physical properties and bond strength of methacrylate-[Clearfil SE Bond (Kuraray) + Filtek Z250 (3M ESPE)] and silorane-based [FiltekP90 system (3M ESPE)] restorative systems, light-cured with a second generation LED according to experimental groups. Specimens were carried out for the degree of conversion (DC) test; the absorption spectra were obtained by FT-IR and FTRamanspectroscopy for the adhesives (n = 10) and composites (n = 5), respectively. The Knoop hardness (KH) was evaluated at the top and bottom of the composites (n = 10). After 24 h of immersion in absolute ethanol, re-reading of KHwas performed to obtain the percentage reduction of the hardness. The water sorption (WS) and solubility (S) tests of the adhesives (n = 5) and composites (n =5) were performed according to ISO 4049:2009, except for specimens' dimension and light-curing protocol. For the bond strength (n = 7) and nanoindentation (n = 3) tests, Class II cavities were performed on the proximal of human molars, which were restored with the restorative systems evaluated. The micro tensile test was carried out in an universal testing machine under cross-head speed of 0.5 mm/min.In the nanoindentation technique were measured the nanohardness (NH) and reduced elasticity modulus (Er) of the dentin, hybrid layer, adhesive, and composite. The data obtained were subjected to statistical analysis (alpha = 0.05).For the adhesives the highest energy density improved only the DC (p < 0.05); the "primer" of the P90 exhibited greater DC, WS, and S compared to "bond" of the Clearfil and P90 (p < 0.05). The methacrylate composite showed higher DC, KH, P, and WS (p < 0.05) than silorane. There was no difference in the S of the composites (p > 0.05). Generally the top surface showed greater of DC and KHthan base (p < 0.05). The methacrylate-based restorative system, as well as increased energy density showed higher bond strength (p < 0.05), with no difference between 24 h and 6 months (p > 0.05). The NH and Ervalues methacrylate-based materials were greater than silorane (p < 0.05). The higher energy density did not improve the NH and Er materials (p > 0.05). The aging decreased the most nanomechanical properties of the components of the tooth restoration interface (p < 0.05), except the NH and Er of the composite and Erof the adhesive (p > 0.05). Thus, it can be concluded that the physical properties and bond strength were material-dependent; the highest energy density improved the bond strength, but not influenced, in general, physical and nanomechanicalproperties; and the aging reduced the most nanoproperties of the components of the tooth-restoration interface, but did not affect the bond strength of restorations / Doutorado / Dentística / Doutor em Clínica Odontológica
112

Influencia dos ciclos termicos e mecanicos na resistencia de união de restaurações classe II em resina composta confeccionadas com tres sistemas adesivos / Influence of thermal and mechanical load cycling on bond strength of Class II composite resin restorations using three adhesive systems

Mitsui, Fabio Hiroyuki Ogata 16 March 2005 (has links)
Orientador : Giselle Maria Marchi Baron / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T02:47:56Z (GMT). No. of bitstreams: 1 Mitsui_FabioHiroyukiOgata_D.pdf: 4372212 bytes, checksum: 0f847604a188d129f752d02dbdae8281 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a influência da aplicação de ciclos térmicos e de carga mecânica na resistência de união à microtração, em restaurações de resina composta em cavidades Classe II do tipo ¿slot¿ vertical, com margem em dentina, confeccionadas com três sistemas adesivos. Cento e sessenta e oito cavidades foram preparadas nas superfícies proximais de dentes bovinos e distribuídas, aleatoriamente, de acordo com o sistema adesivo a ser aplicado (Single Bond, OptiBond Solo Plus e Clearfil SE Bond). Após a restauração das cavidades, utilizando o compósito resinoso Filtek Z250, foi realizada nova distribuição dos dentes, de acordo com o tipo de tratamento (térmico / mecânico) aos quais os dentes foram submetidos, formando dessa maneira 21 grupos experimentais no total (n=8): I - sem tratamento (controle), II - 100.000 ciclos mecânicos (CM), III - 200.000 CM, IV - 500.000 CM, V - 100.000 CM + 1000 ciclos térmicos (CT), VI - 200.000 CM + 1000 CT, VII - 500.000 CM + 1000 CT. A ciclagem térmica submeteu os espécimes a banhos de 60 segundos, a temperaturas de 5 e 55oC. Já o teste de ciclagem mecânica foi realizado mediante aplicação de força axial de 80N e freqüência de 2Hz. Após os ensaios de ciclagem, as restaurações sofreram três cortes seriados, perpendicularmente à parede cervical das restaurações, de forma a obter-se duas fatias no centro da restauração com espessuras de 0,8 a 1mm cada. As fatias obtidas foram desgastadas precisamente em lados opostos da interface adesiva, determinando-se uma área de secção transversal de 0,8 a 1mm2. Todos os espécimes obtidos foram submetidos ao teste de microtração a uma velocidade de 0,5 mm/min até a fratura. Após o ensaio, as duas porções fraturadas de cada espécime foram avaliadas em MEV para análise dos padrões de fratura. Os valores de resistência de união (MPa) foram submetidos à análise de variância 3 fatores e teste Tukey, com nível de significância de 5%. Para a análise dos protocolos de envelhecimento em relação aos grupos controles de cada adesivo, foi aplicado o teste de Dunnett ao mesmo nível de significância de 5%. O sistema adesivo autocondicionante apresentou médias de resistência de união significativamente menores em relação aos adesivos que preconizam o condicionamento total (p<0,0001) e, além disso, os espécimes restaurados com esse adesivo não resistiram à aplicação de 200.000 e 500.000 CM associados à CT. A efetividade dos protocolos de envelhecimento realizadas no estudo variou de acordo com o sistema adesivo avaliado, sendo que a aplicação de 100.000 ciclos de carga isoladamente não acarretou em uma diminuição significativa das médias de resistência de união. O padrão de fratura variou de acordo com o grupo analisado, tendo sido verificado todos os tipos de fratura nos espécimes avaliados. Na medida em que se aumentavam as tensões (ciclagens térmica e mecânica) a que os espécimes foram submetidos, diminuiu o número de fratura na interface e aumentou o percentual das fraturas mistas / Abstract: The aim of this study was to evaluate the influence of thermal and mechanical loading cycling on microtensile bond strength of Class II composite restorations in dentin, with three adhesive systems. One hundred and sixty eight slot vertical cavities were prepared on proximal surfaces of bovine teeth, and divided according to the adhesive system used (Single Bond, OptiBond Solo Plus, and Clearfil SE Bond). All cavities were filled with Filtek Z250 composite resin. Following restorative procedures, the teeth were once again allocated into different groups according to the thermal / mechanical treatment, thus obtaining 21 experimental groups (n=8): I - control, II - 100,000 mechanical cycles, III - 200,000 mechanical cycles, IV - 500,000 mechanical cycles, V - 100,000 mechanical cycles + 1,000 thermal cycles, VI - 200,000 mechanical cycles + 1,000 thermal cycles, VII - 500,000 mechanical cycles + 1,000 thermal cycles. Thermal cycling was performed by submitting the specimens to alternating 5o and 55oC baths, with a dwell time of 60 seconds in each bath. The teeth were then submitted to mechanical load cycling with an occlusal force of 80N at a frequency of 2Hz. The restorations were sectioned perpendicular to the cervical bonded interface into two 0.8-1mm thick slabs. The slabs were trimmed at the interface with a fine diamond bur in order to obtain a cross-sectional surface area of 0.8-1mm2. All specimens were then subjected to microtensile testing, at a cross-head speed of 0.5 mm/min, until failure of the specimens. The fractured surfaces were observed with a scanning electron microscope (SEM) to evaluate the fracture mode. Microtensile bond strength mean values (MPa) were subjected to ANOVA 3-way and Tukey¿s test, at significance level of 5%. The Dunnett¿s test was used in order to compare the groups that were submitted to load and thermal cycling with the control groups of each adhesive system (p<0.05). The self-etching primer presented lower bond strength mean values when compared to the total-etch systems (p<0.0001). In addition, the specimens restored with the self-etching primer did not resist to 200,000 e 500,000 load cycles associated with thermal cycling. The effectiveness of the aging protocols performed in this study showed different behavior according to the adhesive system evaluated. The application of only 100,000 load cycles did not present significant lower bond strength mean values. Failure modes varied according to the analyzed group, and all failures modes were verified in the fractured specimens. The number of mixed failures increased and the percentage of interphase failures decreased when the amount of thermal/mechanical cycles applied was higher / Doutorado / Dentística / Doutor em Clínica Odontológica
113

Avaliação da dureza Knoop de compositos restauradores odontologicos fotoativados por diferentes metodos

Correr, Americo Bortolazzo, 1981- 23 February 2005 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:44:40Z (GMT). No. of bitstreams: 1 Correr_AmericoBortolazzo_M.pdf: 259020 bytes, checksum: 914f93eeb01ce339c79428707805acc7 (MD5) Previous issue date: 2005 / Resumo: Os compósitos odontológicos fotoativados são os materiais odontológicos restauradores estéticos mais utilizados atualmente. Dentre suas vantagens estão o controle do tempo de presa e a estética, além de ser desnecessário a confecção de preparo cavitário retentivo. Durante o processo de polimerização, o compósito sofre contração e, dependendo da velocidade da reação, essa contração pode gerar grande tensão na interface dente-restauração, promovendo o aparecimento de fendas e conseqüente falha da restauração. Além disso, para que o compósito apresente propriedades mecânicas adequadas, é necessário que ele atinja alto grau de conversão. O grau de conversão depende da quantidade de energia que é fornecida ao compósito, embora o efeito da densidade energética nas propriedades mecânicas dos compósitos ainda não seja bem evidenciado. Visando o melhor entendimento dos métodos de fotoativação sobre as propriedades finais dos compósitos restauradores odontológicos, este estudo foi dividido em dois trabalhos: O primeiro avaliou o efeito do aumento da densidade energética pelo maior tempo de exposição, mantendo-se a mesma intensidade de luz, sobre a dureza Knoop dos compósitos Z250 e Esthet-X, fotoativados por luz de lâmpada halógena (QTH) - XL2500, luz emitida por diodo (LED) ¿ Ultrablue Is ou arco de plasma de Xenônio (PAC) ¿ Apollo 95E. Os resultados mostraram que o aumento da densidade energética produziu maiores valores de dureza Knoop quando utilizado LED ou PAC. Para QTH não houve diferença significativa. Em relação às fontes de luz, o PAC apresentou menores valores de dureza Knoop quando comparado ao LED e QTH, que não diferiram entre si. Menores valores de dureza Knoop foram encontrados em maiores profundidades dos compósitos. O segundo trabalho verificou a influência da relação intensidade de luz versus tempo de exposição, utilizando a mesma densidade energética, sobre a dureza Knoop dos compósitos Z250 e Esthet-X, fotoativados por QTH, LED e PAC. Os resultados mostraram que independente do compósito e da fonte de luz, os grupos fotoativados por intensidade de luz e tempo de exposição intermediários apresentaram as maiores médias de dureza Knoop em camadas profundas. A relação dureza da base/dureza da superfície mostrou que o compósito Z250 apresentou adequada polimerização até 3 mm quando foi fotoativado por QTH e LED, e até 2 mm para PAC. O compósito Esthet-X apresentou adequada polimerização até 3 mm quando foi fotoativado por luz halógena e até 2 mm para LED e PAC / Abstract: Nowadays, the photoactivated composites are the most used esthetic restorative dental materials in dentistry. The advantages of these materials are the control of setting time and esthetic characteristics. Besides that, it¿s unnecessary to prepare retentive cavity. Composites shrink during the polymerization reaction and a tension can be induced on restoration/tooth interface. Depending on composite/tooth interface bond strength, gaps can be formed in the restoration margins, leading to the failure of restorative procedure. Besides that, a high degree of conversion is necessary for composites to obtain adequate mechanical properties. The degree of conversion depends on energy density supplied to composites. The effects of energy density in mechanical properties of composites have not been satisfactory proved. In an attempt to improve the knowledge of the photo-activation methods upon the final properties of the restorative composite resins, this research was divided in two works. The first study evaluated the effect of increase on exposure time on Knoop hardness of composites Z250 and Esthet-X, photoactivated using XL2500 halogen light (QTH), Ultrablue Is Light emitting diode (LED) and Apollo 95E plasma arc curing (PAC). The results showed that higher Knoop hardness were produced by the increase on exposure time when LED and PAC were used. For QTH, the increase on exposure time did not produced significant effect. Regarding to light sources, PAC presented lower Knoop hardness than QTH and LED, which did not present significant difference from each other. Knoop hardness at deep layers was lower than superficial layers. The second study verified the influence of irradiance versus exposure time, using the same energy density, on Knoop hardness of Z250 and Esthet-X composites photoactivated using QTH, LED or PAC. The results showed that with intermediate light intensity and exposure times, the highest Knoop hardness were obtained, compared to others photoactivation methods. Composite Z250 presented adequate polymerization (bottom/surface relation above 0.8) up to 2 mm deep using PAC and up to 3 mm using QTH and LED. Esthet-X composite presented adequate polymerization up to 2 mm deep, using LED and PAC and up to 3 mm using QTH / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
114

Como as tecnicas restauradoras podem influenciar na qualidade das restaurações esteticas : avaliação da microdureza, selamento marginal e resistencia de união

Cavalcante, Larissa Maria Assad 22 February 2005 (has links)
Orientadores: Luiz Andre Freire Pimenta, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:50:01Z (GMT). No. of bitstreams: 1 Cavalcante_LarissaMariaAssad_M.pdf: 5129389 bytes, checksum: 69fcb025556b8996ea30007b127e03ca (MD5) Previous issue date: 2005 / Resumo: Neste estudo, procurou-se avaliar a influência de alguns fatores envolvidos durante os procedimentos de fotoativação sobre a adaptação marginal e microdureza de restaurações de resina composta; bem como a interferência das metodologias empregadas para estudos de resistência de união ao substrato dental. Os objetivos deste trabalho, composto por quatro artigos científicos foram: A) avaliar a microinfiltração e microdureza de restaurações de resina composta usando três técnicas de fotoativação (convencional, arco plasma de xenônio e soft-start) e duas diferentes resinas compostas (a microhíbrida Filtek Z250 e a compactável Surefil) (Artigo 1); B) avaliar o efeito de diferentes sistemas de luz - lâmpada halógena, luz de arco plasma de xenônio, laser de argônio e um dispositivo a base de luz emitida por diodo (LEDs) - sobre microinfiltração marginal (Artigo 2) e sobre a formação de fendas e microdureza (Artigo 3) de restaurações com margens em esmalte e em dentina, utilizando-se 3 resinas compostas indicadas para dentes posteriores ¿ a microhíbrida Filtek Z250 e duas compactáveis Surefil e Tetric Ceram HB; C) avaliar o comportamento de dois tipos de sistemas adesivos, um de condicionamento ácido total (Single Bond) e um autocondicionante (Clearfil Liner Bond 2V) quando submetidos a dois testes de resistência de união (microtração e cisalhamento). Os resultados encontrados mostraram que as técnicas de ativação não afetaram a microinfiltração quando foi utilizada uma resina microhíbrida, entretanto, para a resina compactável, as restaurações polimerizadas com a técnica convencional apresentaram microinfiltração similar à técnica soft-start, e menor que aquelas polimerizadas com arco plasma de xenônio (Artigo 1). Entretanto, as resinas compostas e os sistemas de luz não interferiram na penetração do corante, não apresentando diferenças estatísticas entre as margens em esmalte e dentina (Artigo 2). Com relação a formação de fendas, não houve diferença estatística entre os sistemas de luz e as resinas compostas para os preparos cavitários com margem em esmalte; por outro lado, para margens em dentina a resina microhíbrida apresentou as menores fendas quando comparada com as resinas compactáveis, já os sistemas de luz não apresentaram diferenças estatísticas entre si (Artigo 3). Os resultados de microdureza apontaram que a resina composta Tetric Ceram HB apresentou menores médias quando comparada com a Surefil e a Filtek Z250, entretanto, os aparelhos não apresentaram influência nos valores de dureza. Com relação à profundidade de polimerização, as superfícies de topo e meio sempre apresentaram maiores valores comparados com a superfície de base (Artigos 1 e 3). Para avaliação da resistência de união, o teste de microtração detectou diferença entre os sistemas adesivos avaliados, enquanto para o teste de cisalhamento diferenças não foram bservadas (Artigo 4). Pode-se concluir, a partir dos dados destes estudos, que os sistemas de luz não interferiram diretamente na adaptação marginal e na microdureza de restaurações de resina composta, porém a formulação do material restaurador tornou-se um fator significativo de influência das variáveis analisadas, e que a escolha da metodologia a ser empregada pode influenciar na detecção dos resultados / Abstract: The development of new restorative adhesive techniques has continuously advanced resulting in huge changes in the adhesive Dentistry. Thus, in this study it was evaluated the influence of some factors involved during the photoactivation procedures on the marginal adaptation and microhardness of Class II resin composite restorations; it was also investigate the influence of the methodologies used to evaluate the bond strength of adhesive materials to the dental substrate. The aims of this study, composed of four scientific articles were: A) to evaluate the microleakage and microhardness of resin composite restorations using three polymerization techniques (conventional, plasma arc curing and soft-start) and two different resin composites (one microhybrid and one packable) (Article 1); B) to evaluate the influence of four photoactivation systems (halogen (QTH); light emitting diode (LED); argon ion laser (AL) and plasma arc curing (PAC)) on microleakage (Article 2), gap formation and microhardness (Article 3) of class II restorations ¿ at dentin and enamel margins, using a microhybrid Filtek Z250 and two packable resin composites (SureFil and Tetric Ceram HB); C) to evaluate the behavior of two adhesive systems: the self-etching primer Clearfil Liner Bond 2V and the total-etch Single Bond when submitted to two bond strength tests: shear bond strength and microtensile. The results showed that the polymerization techniques - conventional, plasma arc curing and soft-start ¿ did not affect the microleakage when a microhybrid resin composite was used. When a packable composite was used, restorations polymerized with Conventional technique presented similar microleakage to restoration polymerized with soft-start and lower than with plasma arc (Article 1). However, no significant differences were found in the microleakage scores among the photoactivation systems and among resin composites used, marginal adaptation was not significantly affected by location (enamel vs. cementum margins) (Article 2). Related to gap formation, there was no significant difference in gap formation among the curing systems and resin composites at enamel margins. However at the dentin margins, the photoactivation methods did not reveal significant differences, but the microhybrid resin composite presented the best results (Article 3). No statistically significant differences were noted between KHN values of Filtek Z250 and Surefil, but Tetric Ceram HB had the lowest KHN. Occlusal and middle KHN were significantly higher than gingival KHN for all materials (Articles 1 and 3). Article 4 demonstrated that specimens used in the microtensile bond strenght test might provide a more accurate detection of differences among the adhesive systems. These findings suggested that different photoactivation systems may have no effect on the microhardness and gap formation, but the resin composite formulation were found to be a significant determinant factor; and that the methodology chosen may interfere in the detection of data / Mestrado / Dentística / Mestre em Clínica Odontológica
115

Avaliação da sensibilidade pos-operatoria de restaurações classe I de composito odontologico utilizando diferentes agentes de união

Casselli, Denise Sa Maia 02 April 2005 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:56:33Z (GMT). No. of bitstreams: 1 Casselli_DeniseSaMaia_D.pdf: 2775830 bytes, checksum: 43dd6d3dde0928950dc7944d0226d0be (MD5) Previous issue date: 2005 / Resumo: Este estudo avaliou a sensibilidade pós-operatória de restaurações Classe I de compósito restauradas com sistema de união de condicionamento total ou autocondicionante. Cento e quatro restaurações defeituosas de amálgama foram substituídas em 52 pacientes. Cada paciente substituiu duas restaurações. Após preparo cavitário confeccionado, as restaurações foram confeccionadas, sob isolamento absoluto utilizando-se Single Bond ou Clearfil SE Bond e um compósito odontológico (Filtek Z250). A sensibilidade foi avaliada antes da substituição (baseline), após 7 dias e 6 meses da troca, utilizando-se estímulo frio e escala analógica de dor. Se ocorresse sensibilidade após 7 dias, os pacientes retornavam após 14 e 30 dias. Os escores foram analisados através de testes não paramétricos: Friedman e Wilcoxon. Nenhuma diferença estatística significativa foi encontrada em relação à sensibilidade pós-operatória no baseline, 7 dias e 6 meses. Também não houve diferença entre os adesivos em qualquer tempo. Nenhuma sensibilidade espontânea foi relatada. Os principais motivos de substituição de restaurações de amálgama, neste estudo, foram fratura da restauração e degradação marginal. Os sistemas de união utilizados nesse estudo não mostraram diferenças em relação à sensibilidade pós-operatória e não mostraram sensibilidade espontânea após 6 meses, quando utilizados de acordo com as instruções do fabricante / Abstract: This study evaluated the post-operative sensitivity of posterior Class I composite resin restorations restored with a self-etching primer or a total-etch bonding system. One hundred and four restorations were replaced by one clinician in 52 patients. Each patient received two restorations. After cavity preparations, the restorations were completed under rubber dam isolation and restored using a Clearfil SE Bond or Single Bond and a resin-based restorative material (Filtek Z250). The sensitivity was evaluated at O (baseline) and 7 days and 6 months using cold stimuli, and recorded using a visual-analogue scale. If sensitivity was experienced on day 7, patients were also contacted on days 14 and 30 to assess the degree of sensitivity. The se ores were analyzed as non-parametric data by means of the Friedman and Wilcoxon tests. No statistieally signifieant differences were found in sensitivity between the two adhesives systems at day O, 7 and 6 months. No spontaneous pos-operative sensitivity was reported. The major reasons for failure of amalgam restorations were fraetures restoration and marginal deficiencies. The adhesive systems used in this study showed no differenees in post-operative sensitivity, and did not show spontaneous sensitivity after 6 months if they were used accordance with manufacturer' s instructions / Doutorado / Dentística / Doutor em Clínica Odontológica
116

Análise da contração linear de polimerização de resinas compostas fotopolimerizáveis / Analysis of linear shrinkage of photo-actived composite resins

Brito, Júnia Ribeiro de 18 August 2018 (has links)
Orientador: Cecília Amélia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-18T19:00:55Z (GMT). No. of bitstreams: 1 Brito_JuniaRibeirode_M.pdf: 3348250 bytes, checksum: 88bd87279275d739ae30a9b4306d65de (MD5) Previous issue date: 2003 / Resumo: A resina composta fotopolimerizável é amplamente utilizada como material dental restaurador tanto em dentes anteriores como em dentes posteriores. Porém, como todo material polimérico, a resina composta também sofre contração devido a sua reação de polimerização. A contração de polimerização das resinas compostas dentais tem sido relatada como causa das falhas na interface dente-restauração, resultando em microinfiltrações de bactérias, com conseqüências negativas para o dente restaurado. O objetivo deste estudo é analisar a contração linear de polimerização de duas resinas compostas fotopolimerizáveis, uma experimental e outra comercial. A experimental foi desenvolvida por Palácio (2003) no DEMA/FEM/UNICAMP. A resina composta comercial é a Z-250/3M. A mudança dimensional que ocorreu durante e após a fotopolimerização foi monitorada durante 5 minutos a partir do instante em que a luz foi ligada. Na metodologia utilizada, os valores da contração linear de polimerização das referidas resinas compostas foram quantificados através da utilização de extensômetros elétricos / Abstract: The composite resin is widely used as a material for the restoration of anterior and posterior teeth. However, like any other polymeric material, the composite resin also presents shrinkage due to it's polymerization reaction. The polymerization shrinkage of dental composite resins has been reported to cause a marginal gap between the cavity wall and the restoration, resulting in bacterial microleakage, with negative consequence for the tooth. The main goal of this study is to analyse the linear shrinkage of two photo-activated dental composite resins. An experimental one, developed by Palacio (2003), and other commercial (Z-250/3M). The measuring time of linear shrinkage was 5 minutes from the start of photoactivation. The dimensional changes which develop during and after the curing of composite resins, were measured by electrical resistance strain gages / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
117

Influência da utilização de nanopartículas de dióxido de silício ou polissiloxano acrilado nas propriedades físicas de materiais resinosos = Influence of silicon dioxide or acrylated polisiloxane on resin-based materials physical properties / Influence of silicon dioxide or acrylated polisiloxane on resin-based materials physical properties

Yanikian, Cristiane Rumi Fujiwara, 1982- 26 August 2018 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T19:03:50Z (GMT). No. of bitstreams: 1 Yanikian_CristianeRumiFujiwara_M.pdf: 6915738 bytes, checksum: 63867fbe5eef071b9c6effe63971fba8 (MD5) Previous issue date: 2015 / Resumo: A utilização de resinas compostas restauradoras cresceu consideravelmente nos últimos anos, porém, a alteração de cor associado à degradação da resina composta ainda é um importante fator para sua substituição. Portanto, o objetivo dos estudos foram de avaliar in vitro as propriedades físicas de diferentes selantes experimentais e os seus efeitos sobre a superfície de resinas compostas. No primeiro capítulo foram abordados os efeitos da utilização de cobertura de nanopartículas de dióxido de silício (SiO2) sobre diferentes resinas compostas. Os grupos experimentais foram divididos de acordo com os fatores resina composta (Filtek Z250XT, Filtek Z350XT e IPS Empress Direct) e a aplicação ou não de cobertura de SiO2 (n=8). Foram avaliados rugosidade superficial (Ra), energia livre de superfície (mJ/cm2), ângulo de contato formado pela água (?o) e alteração de cor (?E) após 24h de armazenamento em água destilada e após 15, 90 e 180 dias de armazenamento em vinho tinto. Os dados obtidos foram analisados por meio de Análise de Variância de Medidas Repetidas e teste de Tukey (?=0.05). O tempo de exposição ao vinho tinto influenciou negativamente em todas as variáveis, a aplicação da cobertura de SiO2 reduziu a energia livre de superfície, tornando as resinas mais hidrófobas. O aumento na rugosidade superficial foi observada a partir de 90 dias para todas as resinas compostas, independente do tratamento. Quanto a alteração de cor, a Filtek Z250XT e a IPS Empress Direct apresentaram menores valores de ?E quando comparadas à Filtek Z350XT. No segundo capítulo, os grupos estudados foram: PER - selante resinoso comercial (PermaSeal); STD - resina padrão manipulada (matriz monomérica Bis-EMA+TEGDMA carregada com 10% de partículas inorgânicas); SIL-resina padrão modificada por nanopartículas de SiO2 e; APS-resina padrão modificada por polissiloxano acrilado (n=10). Foram avaliados grau de conversão (%), sorção de água e solubilidade (µg/mm3) e módulo de elasticidade (GPa) em corpos de prova maciços confeccionados a partir dos selantes resinosos. Para os ensaios de ângulo de contato com a água (?o) e alteração de cor (?E), os selantes resinosos foram aplicados sobre a superfície de discos de resina composta (Filtek Z250XT) para então realizar a avaliação das amostras, um grupocontrole sem tratamento foi incluído nestes ensaios. O ?E foi calculado a partir de medidas obtidas antes e depois de 15 dias de imersão das amostras em vinho tinto. Os resultados foram analisados por meio de Análise de Variância de 1 critério e posterior teste de Tukey (?=0.05). A adição de nanopartículas de SiO2 promoveu menor solubilidade, adequado módulo de elasticidade e menor grau de alteração de cor e; a incorporação de polissiloxano acrilado promoveu melhor grau de conversão, menor sorção de água, apresentou maior hidrofobicidade e causou menor grau de alteração de cor quando comparadas aos controles. Portanto, a incorporação de aditivos hidrófobos não interferiu negativamente nas propriedades físicas dos selantes experimentais e foram efetivos para tornar resinas compostas mais hidrófobas e reduzir a sua alteração de cor / Abstract: The use of restorative composites has been increased in dental practice, however, the color change associated to composite surface degradation is still important issue for composite restorations replacement. Therefore, the aim of these studies were to in vitro evaluate physical properties of different experimental surface sealants and its effects on composite resins surfaces. In the first chapter, it has been evaluated the effects of the silicon dioxide nanoparticles (SiO2) coating on different composites. The experimental groups were divided according to the resin composite type (Filtek Z250XT, Filtek Z350XT and IPS Empress Direct) and application or not of SiO2 coating (n=8). Surface roughness (Ra), surface free energy (mJ/cm2), water contact angle (?o) and color change (?E) were evaluated after 24h deionized water storage and after 15, 90 and 180 days of red wine storage. Data were analyzed using Repeated Measures ANOVA and Tukey test (? = 0.05). The red wine storage time negatively influenced all variables, irrespective of treatment or resin composite. The SiO2 coating application decreased the surface free energy, making the composite more hydrophobic. The increase in surface roughness was observed from 90 days for all composites, regardless of treatment. Significant less color change was observed in the Filtek Z250XT and the IPS Empress Direct compared to Filtek Z350XT. In the second chapter, the groups were: PER-commercial resin-based coating (PermaSeal); STD-standard manipulated resin (Bis-EMA+TEGDMA-based monomer matrix loaded with 10% of inorganic filler); SIL-standard resin modified by SiO2 nanoparticles adding; APS-standard resin modified by acrylated polysiloxane adding (n = 10). The degree of resin conversion (%) Water sorption and solubility (mg/mm3) and elasticity modulus (GPa) were evaluated in massive specimens prepared from the resin-based coatings. These resin-based coatings were applied on the composite resin discs surfaces (Filtek Z250XT) to water contact angle (?o) and color change (?E) tests. A control group without surface treatment was included in these trials. The ?E was calculated from measurements taken before and after 15 days of red wine storage. The results were analyzed using one - way ANOVA and Tukey test (? = 0.05). The addition of SiO2 promoted lower solubility, appropriate elasticity modulus and lower degree of color change, and; the incorporation of acrylated polysiloxane provided better degree of conversion, reduced water sorption, the highest hydrophobicity and cause less color change compared to that of controls. Therefore, the incorporation of hydrophobic additives did not negatively affect the physical properties of the resin-based coatings and were effective to make the composite more hydrophobic and less stain susceptible / Mestrado / Dentística / Mestra em Clínica Odontológica
118

Efeito do envelhecimento artificial acelerado, clareamento e manchamento nas propriedades físicas de um compósito nanoparticulado = Effect of accelerated artificial aging, bleaching and staining of physical properties of a nanofilled composite / Effect of accelerated artificial aging, bleaching and staining of physical properties of a nanofilled composite

Gouveia, Thayla Hellen Nunes, 1985- 27 August 2018 (has links)
Orientador: Debora Alves Nunes Leite Lima / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T07:56:52Z (GMT). No. of bitstreams: 1 Gouveia_ThaylaHellenNunes_M.pdf: 2628593 bytes, checksum: 44232982dae72b94fe8955775a8a2ab8 (MD5) Previous issue date: 2015 / Resumo: O objetivo deste estudo in vitro foi avaliar as propriedades físicas de uma resina composta nanoparticulada submetida ao envelhecimento artificial acelerado (AAA), ação de agentes clareadores e manchamento extrínseco. O estudo foi dividido em 2 experimentos. O experimento 1 avaliou a influência do AAA e do peróxido de carbamida a 16% com diferentes espessantes na retenção do brilho (GU), cor (?E), microdureza (KHN) e rugosidade média (Ra) de superfície do compósito. A análise qualitativa da superfície de resina foi realizada através de microscopia de força atômica. Cem amostras cilíndricas (7,0mm x 2,0mm) foram confeccionadas e distribuídas aleatoriamente em 10 grupos (n=10). Somente metade dos grupos foram envelhecidos. Para o tratamento clareador/espessante, os grupos com e sem AAA foram divididos em: peróxido de carbamida 16% (PC) com carbopol, PC com natrosol, gel de carbopol, gel de natrosol e sem tratamento (controle). Os dados obtidos foram analisados por meio de ANOVA dois fatores e teste de Tukey. Para o ?E as comparações múltiplas foram realizadas pelos teste de Tukey e Dunnett. Os valores de rugosidade foram analisados pelos testes de Kruskal Wallis, Dunn e Mann Whitney. O nível de significância considerado foi de 5%. O PC com carbopol promoveu redução apenas na microdureza do compósito, diferindo estatisticamente do controle. Para o PC com natrosol esta alteração não foi observada. O PC com carbopol aumentou a rugosidade e diminuiu o brilho das resinas envelhecidas, enquanto o natrosol só o briho foi reduzido, diferindo estatisticamente do grupo controle. O Experimento 2 avaliou a influência dos tratamentos clareadores em diferentes concentrações e manchamento com café na propriedades físicas anteriormente citadas da resina nanoparticulada, submetidas ou não ao AAA. Duas amostras representativas de cada grupo foram avaliadas em microscopia eletrônica de varredura. Cento e vinte amostras cilíndricas foram confeccionadas, semelhante ao estudo anterior, distribuídas em 12 grupos (n=10). Metade das amostras foram envelhecidas artificialmente. Para o tratamento clareador/pigmentação, os grupos com e sem AAA, foram divididos em: peróxido de carbamida a 10% (PC 10%), peróxido de hidrogênio a 35% (PH 35%) e sem tratamento clareador, com e sem pigmentação por café. Os dados foram coletados e submetidos a ANOVA três fatores e teste de Tukey para comparações múltiplas. Para o ?E as comparações múltiplas foram realizadas pelos testes de Tukey e Dunnett (?=0,05). Nas resinas sem envelhecimento, os agentes clareadores reduziram a microdureza do compósito, entretanto a rugosidade, brilho e cor não apresentaram alterações. Após o envelhecimento, o PC 10% aumentou a rugosidade e diminuiu o brilho comparado ao PH 35%. A pigmentação também reduziu a microdureza das resinas sem e com envelhecimento e alterou a cor das resinas envelhecidas (?E>25). Portanto, a ação dos géis clareadores reduziu a microdureza do nanocompósito, sendo que a composição do gel clareador influenciou nessa alteração. O AAA promoveu significativas alterações nas propriedades físicas avaliadas, além de favorecer uma maior degradação da superfície da resina pelo agente clareador e este efeito contribuiu para um maior manchamento extrínseco / Abstract: The aim of this in vitro study was to evaluate the physical properties of a nanocomposite subjected to artificial accelerated aging (AAA), to the action of bleaching agents and to extrinsic staining. This study was divided into two experiments. Experiment 1: evaluate the influence on a composite surface of AAA and 16% carbamide peroxide with different thickeners, in gloss retention (GU), color (?E), microhardness (KHN) and roughness (Ra). Qualitative analysis of the resin surface was performed by atomic force microscopy. One hundred cylindrical samples (7.0mm x 2.0mm) were prepared and randomly divided into 10 groups (n = 10). Only half of the groups were aged. For the bleaching/thickening treatment, the groups with and without AAA were divided into groups/ treatments: 16% carbamide peroxide (PC) with carbopol, PC natrosol, carbopol gel, natrosol gel and untreated (control). Data were submitted to two-way ANOVA and Tukey¿s test for multiple comparisons. The multiple comparisons for ?E were performed by using Tukey¿s and Dunnett¿s tests, and roughness values was analysed by using Kruskal-Wallis, Dunn¿s, and Mann-Whitney¿s tests (? =0.05). The PC with carbopol promoted a decreased in the composite microhardness differing significantly from the control. As for CP + natrosol this change in the microhardness was not observed. The treatment with CP + carbopol increased the roughness and decreased the gloss of the aged resins, whereas natrosol reduced only the gloss which differed statistically from the control. Experiment 2: evaluate the influence of bleaching treatments with different concentrations and coffee staining, in the physical properties of nanocomposite, submitted or not to AAA. Two representative samples of each group were evaluated in scanning electron microscopy (SEM). One hundred twenty cylindrical samples were prepared similar to the previous study and divided into 12 groups (n = 10). Half of specimens were artificially aged. For the bleaching/pigment treatment, groups with and without AAA, were divided into the following groups: 10% carbamide peroxide (10% CP), 35% hydrogen peroxide (35% PH) without bleaching treatment, with and without pigmentation of coffee. Data were submitted to three-way ANOVA and Tukey¿s test for multiple comparisons. The multiple comparisons for ?E were performed by using Tukey¿s and Dunnett¿s tests (?=0,05). The resins without aging, the bleaching agents promoted a reduction in the composite microhardness, however, in the roughness, gloss and color this changes were not observed. After aging, the pigmentation also reduced the microhardness of the resins with and without aging and altered the color of the aged resins (?E> 25). 10% PC increased roughness and decreased gloss compared to 35% PH. Pigmentation also reduced the microhardness of the resins with and without aging and change the color of the aging resins (?E> 25). The action of bleaching agents reduced the microhardness of the nanocomposite, and this alteration was influenced by the composition of the bleaching gel. The AAA promoted significant changes in the evaluated physical properties and favored the further deterioration of the resin surface by the bleaching, contributing to a greater extrinsic staining / Mestrado / Dentística / Mestra em Clínica Odontológica
119

A clinical study of sealants polymerized with two different light sources

White, Marcia Stoddart January 2004 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This clinical study investigated the efficacy of the new LED LCU technology when compared to that of the QTH LCU by evaluating retention and wear of Clinpro (3M ESPE) sealant material over six months of function. This study was designed as a split mouth, randomized clinical study. Sealants were placed and polymerized on contralateral teeth of 35 patients, 33 of which successfully completed the study. The sealants were evaluated for clinical retention at baseline, three months, and six months by two evaluators. For the wear analysis, the area of the sealant wear at six months is reported. Nine pairs of molars and 22 pairs of premolar teeth were used. This sample size is smaller than the original sample used for clinical evaluation, because a number of the baseline impressions had to be discarded due to poor impression quality. Subsequent impressions were taken at three months, and six months. Epoxy replicas were made from the impressions and the occlusal surface of each replica was digitized using SigmaScan software. A cummulative legit model was applied to the clinical data, and a linear model was applied to the wear analysis. The results for clinical retention over the six months of function were as follows. At Baseline, for the QTH, 97.3 percent of the teeth received an Alpha score; 2.7 percent received a score of B. For the LED, 87.7 percent received a score of A; 12.3 percent received a score of B. At three months follow-up, for the QTH, 93.1 percent received a score of A; 6.9 percent received a score of B. For the LED, 86.1 percent received a score of A; 12.5 percent received a score of B, and 1.14 percent received a score of C. At six months follow-up, for QTH; 91.7 percent received a score of A; 8.3 percent received a score of B. For the LED, 83.3 percent received a score of A; 15.3 percent received a score of B, and 1.14 percent received a score of C. The hypothesis was that there would be no significant difference in clinical retention and wear of Clinpro's sealant polymerized with the QTH or the LED light sources over six months of function. Based on the results of this clinical study, the following conclusions can be made: 1) At baseline, Clinpro's sealant polymerized with QTH light source showed marginally significant better retention than LED light source (p-value 0.05001). 2) There was no significant difference between light sources for sealant clinical retention at three-month and six-month follow up visits. 3) Wear analysis resulted in marginally significant more wear for molar sealants polymerized with LED LCU (p-value 0.0755). 4) Wear analysis showed no significant difference for premolar sealants polymerized with either light source.
120

Cuspal Deflection in Premolar Teeth Restored with Bulk-Fill Resin-Based Composite Materials

Elsharkasi, Marwa M.O. January 2015 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objectives: To investigate the effect of bulk-fill resin based composite materials on cuspal deflection in large slot mesio-occlusal-distal cavities (MOD) in premolar teeth. Methodology: Thirty-two sound maxillary premolar teeth with large slot MOD cavities were distributed to four groups (n=8). Three groups were restored with bulk-fill resin composite materials (Tetric EvoCeram, x-tra fil, and Sonic Fill, respectively) in a single increment. The conventional composite group, Filtek Z100, was used to restore the cavities in 2mm increments. Cusp deflection was recorded post irradiation using a Nikon measurescope UM-2 (Nikon, Tokyo, Japan), by measuring the changes in the bucco-palatal width of the premolar teeth at 5 minutes, 24 hours, and 48 hours after completion of the restoration. The cuspal deflection was obtained by recording the difference between the baseline measurements and the other measurements for each tooth. Results: Cuspal deflection was significantly higher in Conventional Composite than in Tetric EvoCeram Bulk Fill (p=0.0031), x-tra Fil Bulk (p=0.0029), and SonicFill Bulk (p=0.0002). There was no significant difference in cuspal deflection for Tetric EvoCeram Bulk, X-tra Fil Bulk, and SonicFill Bulk Composites. Conclusions: All the investigated bulk-fill resin composites exhibited cuspal deflection lower than conventional resin composite. One of the aims of research and studies on the resin composite materials is improving their clinical longevity, and simplifying their use. For that purpose bulk-fill materials are considered promising materials and further clinical studies should be conducted.

Page generated in 0.0639 seconds