• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Investigations in the correlation between hardness and flexural strength of composite resin restorative materials /

Roeske, Svenja. January 1900 (has links)
Diss. med. dent. Zürich. / Literaturverz.
82

Influência da interposição de diferentes cerâmicas no grau de conversão de agentes cimentantes resinosos

Marinho, Márcio Leandro Von Dreifus [UNESP] 01 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-01Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1 marinho_mld_me_araca.pdf: 375522 bytes, checksum: 570c0f27d21f52f32fceab1b3e2a8557 (MD5) / 3M ESPE / O objetivo deste estudo foi avaliar o grau de conversão de agentes cimentantes resinosos polimerizados sob diferentes espessuras de cerâmica feldspática e diferentes sistemas cerâmicos de mesma espessura. No primeiro estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e RelyX Veneer (3M Espe) foram confeccionadas sob discos de cerâmica convencional Starlight (DeguDent) com espessuras de 0,5mm, 1,2mm, 1,8mm e 2,4mm. No segundo estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e Maxcem Elite (Kerr) foram confeccionadas sob discos de diferentes sistemas cerâmicos: Starlight (DeguDent), Empress (Ivoclair Vivadent), E-max (Ivoclair Vivadent), In Ceram Alumina (Vita) e In Ceram Zircônia (Vita) com espessuras de 2,0mm. A leitura do grau de conversão dos cimentos resinosos foi realizada 10 minutos, 1 hora e 24 horas após a fotoativação dos cimentos, em espectrofotômetro FTIR Nexus 670 (Nicolet). Os resultados do primeiro estudo mostraram que o cimento resinoso dual RelyX ARC apresentou maior grau de conversão que o cimento fotoativado RelyX Veneer em todas as espessuras de cerâmica, inclusive sem interposição (p<0.0001). Os valores de grau de conversão obtidos após 1 hora e 24 horas não diferiram estatisticamente entre si (p=0.7433), mas foram superiores aos analisados após 10 minutos (p<0.0001). Para o cimento fotoativado, houve aumento gradativo no grau de conversão de 10 minutos até 24 horas (p<0.0001). No segundo estudo, os maiores valores de grau de conversão foram obtidos para as amostras polimerizadas sob as cerâmicas reforçadas por leucita e dissilicato de lítio, sem diferença estatisticamente significante entre si (p=0.1181), enquanto os menores valores do grau de conversão obtidos foram das amostras polimerizadas sob cerâmicas reforçadas por alumina e zircônia, sem diferença entre si (p=0.2374). Com base nos resultados destes... / The aim of this study was to evaluate the degree of conversion of resin cements polymerized under different thicknesses of feldspatic ceramic and different ceramic systems with the same thickness. In the first study, eighty samples of RelyX ARC (3M Espe) and RelyX Veneer (3M Espe) were polymerized under conventional ceramic discs (Starlight, DeguDent) with thickness of 0.5 mm 1.2 mm, 1.8 mm and 2.4 mm. In the second study, eighty samples of RelyX ARC (3M Espe) and Maxcem Elite (Kerr) resin cements were polymerized over ceramics systems: Starlight (DeguDent), Empress (Ivoclar Vivadent), E-max (Ivoclar Vivadent), In Ceram Alumina (Vita) and In Ceram Zircon (Vita) with 2.0 mm of thickness. The degree of conversion of the resin cements was calculated 10 minutes, 1 hour and 24 hours after the curing of cements using a Nexus 670 FTIR spectrophotometer (Nicolet). The RelyX ARC showed higher values of degree of conversion than RelyX Veneer considering all the ceramics thickness in the first study. The measurements obtained after 1 hour and 24 hours did not differ significantly (p=0.7433), but were higher than those analyzed after 10 minutes (p<0.0001). Comparing the ceramic systems in the second study, the highest degree of conversion were obtained for samples polymerized under Empress and e.max ceramics, without statistically difference between them (p= 0.1181) and the lower values of conversion were obtained for the samples polymerized under In Ceram Alumina and In Ceram Zircon ceramics (p= 0.2374). Based on the results of these studies, we can conclude that the thickness of feldspatic porcelain as well as the ceramic system itself could influence the degree of conversion of light- and dual-cured resin cements. All the resin cements showed an increase on the degree of conversion after 24 hours, which could create an especial guideline for the clinical procedures using resin cements
83

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores /

Carlo, Hugo Lemes. January 2004 (has links)
Orientador: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: Jesuania Maria Guardiero Azevedo Pfeifer / Abstract: The aim of this work was to evaluate the linear polymerization shrinkage and the degree of conversion of two commercial composite resins, with similar compositions, being one of use in anterior and posterior teeth (Filtek Z250) and other for use in posterior teeth (Filtek P60). The effect of different light sources was also evaluated in that process, and were used for that an halogen light curing (Degulux - Degussa) and a LED light curing of high intensity (Ultrablue IS - DMC). In that way, the materials and light sources were divided in four groups: Group 1 - Filtek Z250 resin cured with the halogen light curing (QHT); Group 2 - Filtek Z250 cured with LED light curing (LED); Group 3 - Filtek P60 resin cured with the halogen light curing (QHT); Group 4 - Filtek P60 cured with the LED light curing (LED). The polymerization shrinkage was measured with the insert of the materials in a plastic tube and the values of the alterations accomplished by an electronic instrument of linear measure with sensibility for 1æm. The conversion degree was obtained through Fourier Transform Infrared Spectroscopy (FTIR), where the picks were analyzed inside of the bands of interest in the values of 1.646 cm-1 and 1.731 cm-1, corresponding to the connections C=C aliphatic and C=O respectively. The results were submitted to the statistical analysis of Variance and test of Tukey (a = 0,05), which allowed to end that: the polymerization shrinkage of different materials (Filtek Z250 and Filtek P60) presented different behavior with the use of the same light source (LED); the degree of conversion of the materials came similar in relation to materials and light sources; the LED light curing (Ultrablue IS) presented results of polymerization shrinkage and degree of conversion that allow it to be used as an alternative to QHT light curing units. / Resumo: O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
84

Avaliação clínica longitudinal de restaurações de uma resina composta bulk-fill em dentes posteriores / Longitudinal clinical evaluation of restorations of a bulk-fill composite on posterior teeth

Rodrigues, Roger Borges January 2016 (has links)
Objetivos: O objetivo deste ensaio clínico randomizado foi avaliar o comportamento de restaurações de resina composta bulk-fill em dentes posteriores (classes I e II). Metodologia: Dezessete pacientes que necessitavam de restaurações em pelo menos dois dentes posteriores foram selecionados para participar do estudo. As causas para indicação das restaurações foram: substituição de restauração deficiente de amálgama ou resina composta e/ou lesão de cárie. Em cada paciente foram realizadas duas restaurações. Randomicamente, uma cavidade foi restaurada com a resina nanohíbrida Esthet-X HD (grupo controle) e a outra restaurada com a resina Esthet-X HD associada à resina de baixa contração Surefil SDR Flow (grupo teste). Em ambos os grupos, um sistema adesivo convencional de dois passos (XP Bond) foi utilizado. Todos os pacientes receberam tratamento global para a atividade cariosa. Após um período de quatro anos, a qualidade das restaurações foi avaliada por 1 examinador previamente calibrado, através de uma modificação do método USPHS e através do método FDI. Os dados obtidos foram submetidos à análise estatística pelo teste não-paramétrico Mann-Whitney (p<0,05) e a concordância intra-observador avaliada através de teste Kappa. Resultados: No quarto ano de acompanhamento, 26 dentes (18 restaurações classe I e 8 classe II) foram avaliadas, e não foram observadas diferenças estatisticamente significantes entre as restaurações dos grupos controle e teste para os métodos de avaliação utilizados. Não houve falhas em nenhuma das restaurações ao longo do tempo. Conclusão: A qualidade das restaurações classe I e II com resina bulk-fill foi semelhante à das restaurações com resina nanohíbrida convencional. A técnica com resina bulk-fill mostrou bom desempenho clínico tão bom quanto a convencional durante os 4 anos de acompanhamento. / Objectives: The objective of this randomized clinical trial was to evaluate the behavior of bulk-fill composite restorations in posterior teeth (classes I and II). Methodology: Seventeen patients who required restorations on at least two posterior teeth were selected to participate in the study. The causes for indication of restorations were: replacement of deficient amalgam or composite resin restoration and/or caries lesion. In each patient, two restorations were performed. Randomly, one cavity was restored with Esthet-X HD nanohybrid composite (control group) and the other was restored with Esthet-X HD resin associated with the bulk-fill composite Surefil SDR Flow (test group). In both groups, a two-step total-etch adhesive system (XP Bond) was used. All patients received global treatment for carious activity. After a period of four years, the quality of the restorations was evaluated by a previously calibrated examiner, through a modification of the USPHS method and through the FDI method. The data were submitted to statistical analysis by the non-parametric Mann-Whitney test (p <0.05) and the intra-observer agreement was evaluated by Kappa test. Results: At the 4-year follow-up, 26 teeth (18 class I and 8 class II restorations) were evaluated, and no statistically significant differences between control and test groups were observed for both evaluation methods used. There were no failures in any of the restorations over time. Conclusion: The quality of class I and II restorations with bulk-fill resin was similar to that of conventional nanohybrid resin. The bulk-fill composite technique showed good clinical performance as well as the conventional one during the 4 years of follow-up.
85

Influência da fonte de luz na estabilidade de cor de resina composta. Efeito dos meios e tempos de imersão

Santos, Patrícia Aleixo dos [UNESP] 13 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-13Bitstream added on 2014-06-13T19:20:25Z : No. of bitstreams: 1 santos_pa_dr_arafo.pdf: 1139131 bytes, checksum: 18d63c9cbe7759346d5e8465937304eb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência da fonte de luz na estabilidade de cor da resina composta nanoparticulada Filtek Supreme submetida a diferentes meios e tempos de imersão. Para isso, foram utilizadas três fontes de luz: um LED UltraLume LED 5/ UltraDent; um aparelho de lâmpada halógena convencional – Curing Light XL 3000/ 3M/ESPE; e um de luz halógena de alta densidade de potência – Jet Lite 4000 Plus/ JMorita. Os espécimes (n=180) foram confeccionados em matriz de metal circular (10mm x 2mm) apoiada em placa de vidro e tira de poliéster. A resina composta foi inserida na matriz num único incremento e fotoativada por 40 segundos. Os espécimes foram divididos em três grupos (equipamento de fotopolimerização) e quatro subgrupos experimentais (meios de imersão: café, Coca-Cola®, chá e saliva artificial). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor no espectrofotômetro de colorimetria (CB-6807 color-guide /BYK-Gardner) pelo sistema CIELab. A partir desse período, passaram a ser mergulhados nos diferentes meios por cinco minutos, três vezes ao dia, por 60 dias, e nos intervalos foram mantidos em estufa à 37°C ± 1°C. A leitura da alteração de cor foi realizada após 24 e 48 horas, 7, 14, 21, 30 e 60 dias do início da imersão. Os dados foram analisados pelo teste não-paramétrico Kruskall-Wallis para os fatores fonte de luz e meio de imersão (p<0,05), enquanto, para o fator tempo, utilizou-se o teste ANOVA a dois critérios e o teste de Fisher (p<0,05). Os resultados mostraram que, para o fator fonte de luz, o Ultralume LED 5 apresentou a menor alteração de cor em comparação aos aparelhos halógenos. Em relação ao meio de imersão, o café mostrou a maior alteração de cor e de luminosidade (ΔE=8,40; _L=-5,21), a Coca-Cola® apresentou os menores valores... / The aim of this study was to evaluate the influence of light sources on color stability of a composite resin and the effect of immersion media. In this test, three light sources were used: a conventional halogen curing light unit (XL3000 – 3M/ESPE), a high power density halogen unit (Jet Lite 4000 Plus – JMorita) and a high power density LED unit (Ultralume LED 5 - Ultradent). There were four media immersion: coffee, tea, Coke® and artificial saliva. One nanofilled composite resin was selected: Filtek Supreme. A stainless steel matrix (10mmx2mm) was used to prepare 180 specimens. After this, all specimens were immersed in artificial saliva for 24hs at 37oC ± 1ºC and its initial color was measured with a spectrophotometer (Color Guide 45/0, BYKGardner) by CIELab system. Then, the specimens were divided into 4 subgroups according to each medium and were immersed in the respective medium three times a day during 5 minutes for 60 days. Color changes were recorded after 24hs, 48hs, 7, 14, 21, 30 and 60 days of immersion. Data from the color change and luminosity were analyzed and subjected to Kruskall-Wallis test to light source and immersion media factor (p<0,05). To immersion time, data were subjected to two-way ANOVA test and Fisher’s test (p<0,05). The light source that more contributed to color stability was Ultralume LED 5. In relation to solutions, coffee caused an intense color alteration (ΔE=8,40; ΔL=-5,21) and Coke® showed the lowest color changes (ΔE=1,43; ΔL=0,36). Then, it might be concluded that Ultralume LED 5 was the light-curing unit that allowed better color stability and coffee was the immersion medium that promoted the highest influence on color stability of the studied composite resin.
86

Efeito de diferentes meios de imersão na emissão fluorescente de resinas compostas

Gaião, Ubiracy [UNESP] 17 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-17Bitstream added on 2014-06-13T19:20:26Z : No. of bitstreams: 1 gaiao_u_dr_arafo.pdf: 721993 bytes, checksum: f5fc596fed638936262956e5eebcb630 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar o efeito do manchamento sobre a intensidade de fluorescência de resinas compostas, em função dos meios de imersão e do tempo. Para isso, foram selecionadas as seguintes resinas compostas: Filtek Supreme XT (3MESPE), 4 Seasons (Ivoclar Vivadent), Venus (Heraeus – Kulzer), Vit~l~escence (Ultradent) e Esthet-X (Dentsply). Foram selecionadas também as seguintes soluções: café, suco de laranja, refrigerante de cola, vinho tinto e saliva (controle). Para cada condição experimental foram confeccionados cinco corpos-deprova (n=5) em forma de disco medindo 10,0mm de diâmetro e 1,0mm de espessura, que permaneceram imersos em saliva artificial e mantidos em estufa a uma temperatura de 37ºC±1. Esses corpos-de-prova foram retirados da estufa três vezes ao dia para imersão nas soluções testadas, durante o período de cinco minutos. Após este período foram lavados em água corrente e novamente imersos em saliva artificial e mantidos em estufa, até o momento da mensuração da intensidade de fluorescência. As leituras foram realizadas em seis níveis de variação: T0 - após confecção dos corpos-de-prova sem imersão em saliva artificial; T1 - 24 horas após imersão em saliva artificial; T2 - 24 horas após imersão nas soluções; T3 - 07 dias após imersão nas soluções; T4 - 14 dias após imersão nas soluções e T5 - 21 dias após imersão nas soluções. Para a obtenção dos valores de intensidade de fluorescência foi utilizado um espectrofotômetro (Spex Triax Fluorolog 3) calibrado para que o raio incidente fosse emitido com um comprimento de onda de 390nm e para que todo o fenômeno de fluorescência fosse registrado em uma faixa compreendida entre 400nm e 700nm. Os resultados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey a 5%. De acordo com os resultados observou-se que as soluções influenciaram... / The aim of this study was to evaluate the effect of staining on the fluorescence intensity of composite resins, depending on the solutions and immersion time. The following composites were selected: Filtek Supreme XT (3MESPE), 4 Seasons (Ivoclar Vivadent), Vênus (Heraeus – Kulzer), Vit~l~escence (Ultradent) and Esthet-X (Dentsply). We also selected the following solutions: coffee, orange juice, cola soft drink, red wine and artificial saliva (control). For each experimental condition were made five specimens (n=5) in a disk shape measuring 10,0mm diameter and 1,0mm thickness. All the specimens were immersed in artificial saliva and kept in an incubator at a temperature of 37ºC±1. The specimens were removed from the incubator three times a day for immersion in the solutions tested, during the period of five minutes. After it was washed in running water and again immersed in artificial saliva, until the time of measurement of fluorescence intensity. The readings were taken at six levels of variation. T0 - 24 hours after preparing the specimens, T1 - 24 hours after immersion in artificial saliva, T2 - 24 hours after immersion in the solutions, T3 after seven days, T4 after fourteen days and T5 after 21 days. To obtain the values of fluorescence intensity, was used a calibrated spectrophotometer (Spex Triax Fluorolog 3) with an incident ray delivered with a wavelength of 390nm. The phenomenon of fluorescence was registered between 400nm and 700nm. The results were submitted to the analysis of variance and Tukey's test 5%. The results showed that the solutions influenced the intensity of fluorescence emitted by resin composites (p<0,05). Coffee was the higher staining solution, followed by red wine, orange juice, cola soft drink and artificial saliva. Regarding the time it was noted that after T2 there was a significant change in fluorescence emission... (Complete abstract click electronic access below)
87

Análise in vitro da influência de três sistemas de fotopolimerização, através da MEV, na amplitude de fendas axiais em cavidades classe V restauradas com resina composta

Gomes, Osnara Maria Mongruel [UNESP] 19 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-19Bitstream added on 2014-06-13T19:41:16Z : No. of bitstreams: 1 gomes_omm_dr_arafo.pdf: 3437835 bytes, checksum: 3849412cc99b583b3e6178479443829a (MD5) / A contração de polimerização é ainda o maior problema das restaurações de resina composta fotopolimerizável, causando a formação de fendas marginais. O objetivo deste estudo in vitro foi avaliar a formação de fendas axiais em restaurações de resina composta classe V usando três diferentes sistemas de fotopolimerização. Cavidades padronizadas foram executadas nas faces vestibular e lingual de trinta terceiros molares humanos, com margens localizadas abaixo da junção cemento/esmalte. Resina composta foi inserida em dois incrementos usando sistema restaurador Filtek A 110 (3M) e Single Bond (3M). Resina composta foi fotopolimerizada usando três sistema de fotopolimerização: Grupo I: Quartzo tungstênio halogênio (QTH) convencional (dois incrementos com 20 seg - 600 mW/cm2 - Optilux 401 Demetron); grupo II: QTH pulso tardio (primeiro incremento com 3 seg - 200 mW/cm2 + 3 min período de espera + 20 seg - 600 mW/cm2 e segundo incremento com 20 seg - 600 mW/cm2 VIPTM Bisco); grupo III: Diodo emissor de luz azul - LEDs (dois incrementos com 20 seg- 400 mW/cm2 - EliparTMFreeLight - 3M ESPE). Em seguida, os dentes foram colocados em água destilada a 37oC durante 24 horas; e as restaurações foram polidas. Os dentes foram submetidos a ciclagem térmica por ciclos à 10oC + 2oC e 50oC + 2oC, com um tempo de permanência de 15 segundos em cada temperatura, realizando um total de 500 ciclos. Os dentes foram seccionados vestíbulo-lingualmente através de cada restauração sob constante refrigeração. A extensão da fenda entre a parede axial e o material restaurador foi observada sob MEV a 500X. Os valores médios da amplitude foram: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm e GIII 1.46 l 2.73 mm. Os dados foram analisados através do teste não paramétrico de Kruskal-Wallis e o teste de comparações múltiplas de Dunn, onde o grupo II... . / Polymerization shrinkage causing marginal gap formation is still a major problem in light curing restorations. The aim of this in vitro study was evaluate the gap formation in axial wall of class V resin composite restorations using three different photocuring technique. Standard cavities were prepared on the buccal and lingual surfaces of 30 human third molars with margins located below the cemento-enamel junction. Resin was inserted in two increments using the restorative system Filtek A110 (3M) and Single Bond (3M). Resin composite were photocured using three polymerization techniques: Group I: Quartz tungsten halogen (QTH) convencional (two increments with 20 sec - 600 mW/cm2 - Optilux 401 Demetron); group II: QTH pulse delay (first increment with 3 sec - 200 mW/cm2 + 3 min waiting period + 20 sec - 600 mW/cm2 and second increment with 20 sec - 600 mW/cm2 VIPTM Bisco); group III: light emitting diode (LEDs) two increments with 20 sec - 400 mW/cm2 - EliparTM FreeLight 3M-ESPE). Before finish and polishing, samples were stored in destiled water at 37ºC for 24 hours. The teeth were termocycled for 500 cycles (10º C l 2º C and 50º C l 2º C) with a dwell time of 15 seconds. The teeth were sectioned buccolingually through each restoration under constant refrigeration. The extend of gaps between the axial dentine wall and the restorative material was assessed under SEM at X500. Results: the mean and range values were as follows: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm and GIII 1.46 l 2.73 mm. The data were analyzed by Kruskal-Wallis and Dunn Tests. Group II showed lower values, followed by group III and group I. Group I showed higher values of gaps. Gaps were observed in all groups. Among polymerization technique used in the study, the group II presented the best performance.
88

Efeito do tipo de adesivo e do seu mecanismo de ativação, assim como da viscosidade da resina composta, na resistência de união à dentina antes e após envelhecimento artificial

Batista, Graziela Ribeiro [UNESP] 26 May 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-05-26. Added 1 bitstream(s) on 2015-06-18T12:46:57Z : No. of bitstreams: 1 000828513.pdf: 787314 bytes, checksum: 37a468b87a2c9b21878598eeb9a09897 (MD5) / O objetivo deste estudo foi avaliar a influência da viscosidade das resinas compostas e do tipo de cura dos sistemas adesivos, na resistência adesiva de resinas diretas submetidas a envelhecimento artificial. Foram utilizados 240 dentes incisivos bovinos, os quais tiveram a face vestibular desgastada para exposição da dentina. Os espécimes foram incluídos em resina acrílica autopolimerizável e a smear layer foi padronizada com lixa P600. Os espécimes foram divididos em 2 grupos de acordo com viscosidade da resina utilizada: Grupo GC: Grandio SO, alta viscosidade e Grupo GF: Grandio SO Heavy Flow, baixa viscosidade. Esses grupos foram subdivididos em 6 subgrupos de acordo com o sistema adesivo autocondicionante utilizado: FM: Futurabond M - fotopolimerizado, FDCQ: Futurabond Dual Cure Quimicamente ativado, FDCF: Futurabond Dual Cure Fotoativado, CS3: Clearfil S3 fotopolimerizado, CDCQ: Clearfil Dual Cure Quimicamente ativado e CDCF: Clearfil Dual Cure Fotoativado. Sobre a superfície dentinária foram construídos blocos de resina com auxílio de matriz de silicone. Os espécimes foram armazenados em água deionizada em estufa a 37 ºC, por um período de 24 h, e cada grupo foi subdividido em dois, sendo metade dos espécimes levados à cortadeira Labcut para obtenção de palitos dentina/resina medindo aproximadamente 1 X 1mm e a outra metade submetida a ciclagem termomecânica (300.000 ciclos mecânicos e 1000 ciclos térmicos) e sequencialmente cortados para obtenção de palitos. Os palitos foram submetidos a teste de microtração na máquina de ensaios universal DL-200MF (EMIC) e os resultados obtidos foram submetidos à análise estatística empregando-se os testes ANOVA 3 fatores e Tukey (α = 5%). O teste ANOVA mostra que houve diferença estatística somente para os fatores Adesivo (p = 0,0000) e Ciclagem termomecânica (p=0,0001), assim como para a interação entre eles ... / The aim of this study was to evaluate the influence of composite resins viscosity and the type of cure of the adhesive systems on the bond strength of direct composite resins submitted to artificial aging. Two hundred forty bovine incisors had the buccal dentin exposed by sandblasting papers and were included in acrylic resin. The smear layer was standardized by sandblasting papers (600 SiC, Fepa-P). The specimens were divided in 2 groups according to the viscosity of the composite resin used: Group GC: Composite Grandio SO, high viscosity and Group GF: Grandio SO Heavy Flow, low viscosity These groups were divided in 6 according to the self-etch adhesive used: FM: Futurabond M - light cured, FDCQ: Futurabond Dual Cure - chemical cured, FDCF: Futurabond Dual Cure - light cured, CS3: Clearfil S3 - light cured, CDCQ: Clearfil Dual Cure - chemical cured and CDCF: Clearfil Dual Cure - light cured. Resin blocks were build up on the dentin surface using a silicon mold. The specimens were stored in deionized water 37°C along 24 h and half of them were cut to obtain resin/dentin sticks (1X1mm) and the other half submitted to thermomechanical aging (300.000 mechanical cycles and 1000 thermal cycles) and lately cut to sticks. The dentin/resin sticks were submitted to microtensile bond strength test (μTBS) in Universal machine DL-200MF (EMIC) and the results were analysed by 3 way ANOVA and Tukey's test (α=5%). ANOVA showed signifficant statistical difference to the parameters: Adhesive (p=0,0000) and Thermomechanical aging (p=0,0001), as well to their interaction (p=0,0062). Tukey's test showed the results: Adhesive: CDCQ: 13,44 (±5,13)a; FM: 14,01 (±2,71)a; CDCF: 14,51 (±4,98)a; FDCQ: 18,66 (±7,13)b; CS3: 18,80 (±6,50)b; FDCF: 19,18 (±7,39)b; Thermomechanical aging: Aged: 14,99 (±6,32)a; Not aged: 17,87 (±5,97)b. The conclusions were: Composite resin viscosities and type of cure...
89

Estudo in vivo e in vitro do vedamento marginal em restaurações de resina composta em cavidades de classe V

Badini, Sérgio Ricardo Garcia [UNESP] 15 May 2001 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-05-15Bitstream added on 2014-11-10T11:57:33Z : No. of bitstreams: 1 000134825.pdf: 6862730 bytes, checksum: 13594d81ed2f21e526a4bb9573ca093a (MD5) / A finalidade deste trabalho foi verificar a possível infiltração marginal, em cavidades de Classe V, restauradas com resina composta e dois sistemas adesivos, variando-se o tipo de metodologia: estudo in vivo e in vitro. No estudo in vitro,foram realizados dois testes laboratoriais: 1) termociclagem, empregando-se 300 ciclos de trinta segundos cada em banhos entre 5a 55 C e, 2)utilizando-se termociclagemmais carga de 33kgf/cem ciclos. Foram utilizadas 60 pré-molares humanoshigidos, onde foram confeccionados preparos cavitários de Classe V com dimensões de aproximadamente 2mm de largura X 2mm de altura X 1,5rnmde profundidade. Os dentes para os testes in vitroforam aleatoriamente divididosem quatro grupos de dez dentes cada: grupo 1 - aplicação de carga etermociclagem com o emprego do adesivo Single Bond; grupo 2 - aplicação decarga e termociclagem com o emprego do adesivo Prime & Bond NT; grupo 3 -aplicação de termociclagem com o emprego do adesivo Single Bond; grupo 4 -aplicação de termociclagem com o emprego do adesivo Prime & Bond NT. Osdentes foram pintados com esmalte de unha, respeitando-se a distancia de 1 mm darestauração, ficaram imersos em solução de nitrato de prata a 50% por 24 horas,lavados e secos e expostos a luz fluorescente por oito horas em solução reveladora Kodak. Apos esse período, os dentes receberam duas secções no sentido oclusogengival, para verificar a infiltração em estereomicroscópio. Para os estudos invivo, formaram-se dois grupos: grupo 5 - aplicação do sistema adesivo SingleBond; grupo 6 - aplicação do sistema adesivo Prime & Bond NT. Apos os vinte edois dentes terem sido restaurados e permanecidos em função por sessenta dias, osmesmos foram extraídos, limpos e pintados com esmalte de unha, respeitando-se a distancia de 1 mm da restauração, ficaram imersos em solução de nitrato de prata a50% por 24 horas, lavados e secos e ... / The purpose of this study was to verify the marginal infiltration, in restorations of Class V, restored with composed resin and two adhesive systems, being varied the methodology type: study in vivo and in vitro. In the study in vitro, two tests was accomplished: I) thermocycling, with 300 cycles of thirty seconds each in bathing among 5ºtu 55º C and2) study in vitro being used thermocycling more load of 33kgf/100 cycles. 60 higidhuman bicuspids were used, where cavity of Class Vwere made with dimensionsof approximately 3mm of widthX 2mm of height X2mmof depth. The teeth for the tests in vitro were handomlydivided in four groups of ten teeth each: a) group 1- load application and thermocycling with the employment of adhesive Single Bond; b) group 2- load application and thermocyclingwith the employment of the Pime&Bond NT; c) group 3- thermocyclingapplication with the employment of adhesive Single Bond; d) group4 - thermocycIingapplication with the employment of the Prime &Bond NT. Theteeth were colored with fingernail enamel, being respected distances if of 1mm of the restoration, they were immerged in solution of silver nitrate at 50% for 24 hours, washed and dryand exposed to the fluorescent light by eight hows indeveloping solution Kodak. After that period, the teeth received two cuts in oclusogengival sense, to verify the infiltration in stereomicroscopy. For the studies in vivo, they were formed twogroups: e) group 5 - application of the adhesive system Single Bond; f) group 6 - applicationof the adhesive systemPrime &Bond NT. After the restorations complete, the twenty teeth stayed in function by sixty days. They were extracted, clean and painted with fingernail enamel, being respected distances it of 1mm ofthe restoration, they were immerged in solution of silver nitrate at 50% for 24hours, washed and dry and exposed to the fluorescentlight by eight hours in developing solution Koda...
90

Avaliação da resistência à flexão e do módulo de elasticidade de diferentes materiais restauradores poliméricos tratados ou não termicamente após a fotoativação /

Watanabe, Mauricio Umeno. January 2016 (has links)
Orientador: Mirela Sanae Shinohara / Banca: Alberto Carlos Botazzo Delbem / Banca: Eduardo Passos Rocha / Banca: Mario fernando de Goes / Banca: Rodolfo Bruniera Anchieta / Resumo: Objetivo: Resinas compostas para uso direto têm sido frequentemente usadas pelos profissionais para confecção de restaurações indiretas extensas. O objetivo do presente estudo foi avaliar a resistência à flexão (RF) e o módulo de elasticidade (ME) de diferentes materiais restauradores poliméricos diretos, nos tempos de 30min e 24h sem tratamento térmico (TT); e quando submetidos ou não ao TT, sendo armazenados ou não por 180 dias. Materiais e método: Foram confeccionados 200 corpos de prova divididos nos seguintes grupos de acordo com o material: o ormocer microhíbrido Admira Fusion (ADM), a resina tipo "bulk" nanoparticulada Filtek Bulk Fill (BU), a resina composta convencional nanoparticulada Filtek Z350XT (Z350) e resina composta convencional microhíbrida IPS Empress Direct (EMP). Os grupos foram subdivididos (n=10) nos tempos de 30min sem TT, 24h com e sem TT ou 180 dias com e sem TT. Os corpos de prova (10 mm x 2 mm x 2 mm) foram confeccionados usando-se um molde tripartido de aço inox, no qual o material foi inserido em incremento único e fotoativado por 20s de cada lado. No final do período de 24h da fotoativação, o TT foi realizado por 10min em estufa à temperatura controlada de 170⁰C. O armazenamento das amostras de 180 dias foi em água destilada em ambiente escuro a 37⁰C. O teste de resistência à flexão de 3 pontos foi realizado em uma máquina de ensaio Instron à velocidade de 1,0 mm/min. Resultados: Os resultados foram obtidos em MPa (RF) e GPa (ME), sendo depois s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose : Direct composite resins are often used by professionals for making extensive indirect restorations. The aim of this investigation was to evaluate flexural strength and elastic modulus of different rest orative polymeri c materials at 30 minutes and 24 hours without heat treatment (HT); and with and without HT at 24 hours and 180 days post cure . Materials and method: 200 samples were prepared and divided accord ing to the material as follows : microhybrid ormocer Admira Fu sion (ADM), nanofilled bulk - fill composite resin Fitek Bu lk Fill (BU), nanofilled universal composite resin Filtek Supreme Ultr a (Z350) and microhybrid universal composite resin IPS Empress Direct (EMP). Groups were subdivided (n=10) at 30 minutes into: wi thout HT (30 min), 24 h with and without HT and 180 days with and without HT. The samples (10 mm x 2 mm x 2 mm) were made in a tri - part stainless steel mold where t he material was inserted and light - cured for 20 seconds on each side. At the end of the 24 h period HT at 170 ⁰ C was performe d for 10 minutes in a dry heat oven. The 180 day storage samples were placed in destilled water at 37 ⁰ C i n the dark. A standard three point bending test was conducted on all samples with a universal testing machine (Instron) at a crosshead speed of 1.0 mm/min. Results: The results were recorded in MPa (flexural strength ) and GPa (elastic modulus) and data were analyzed statistically at a significance level of 5% . All the materials had a significant increase in flexural str ength and elastic modu lus from 30 minutes to 24 hours (p<0. 05). HT promoted an increase in flexural strength for BU and EMP at 24 hours and Z350 at 180 days (p<0,05). Storage di dn't influence flexural strength for BU without HT. HT promoted elastic modulus increase for ormocer ADM at both testing times and for EMP, BU and Z350 at 24 hours (p<0.05). Wit... (Complete abstract electronic access below) / Doutor

Page generated in 0.0789 seconds