• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Selamento de lesões cariosas oclusais : um ensaio clínico randomizado

Giongo, Fernanda Cristina Mendes de Santana January 2010 (has links)
As evidências mostram uma redução ou eliminação significativa na quantidade de bactérias viáveis sob selantes e restaurações e consequente diminuição na progressão da cárie quando as bactérias se encontram separadas do meio bucal. O objetivo deste ensaio clínico controlado randomizado foi avaliar a eficácia de duas estratégias de tratamentos: 1) selamento de lesões de cárie oclusal e 2) tratamento restaurador convencional com remoção total da dentina cariada em dentes permanentes. A amostra foi constituída de 52 dentes com lesões de cárie na superfície oclusal (pré-molares e/ou molares) de 47 pacientes com idade entre 8 a 43 anos. Todas as lesões de cárie apresentaram necessidade de tratamento restaurador de acordo com os seguintes critérios: presença de cavidade e impossibilidade de controle do biofilme. A profundidade máxima das lesões foi até a metade externa de dentina avaliada através de radiografias interproximais. Os dentes foram divididos aleatoriamente em um grupo teste - tratamento selante, ou grupo controle - tratamento restaurador convencional. Dados iniciais referentes à experiência de cárie (CPOD) e índice de sangramento gengival (ISG) foram avaliados. Radiografias interproximais foram realizadas após 12 meses para avaliar a integridade das restaurações e a zona radiolúcida (ZR) sob os selantes/restaurações. Os desfechos analisados foram o desempenho clínico dos tratamentos selante e restauração e a prevalência de regressão, inativação e progressão da cárie com exames radiográficos. A presença de dentina terciária também foi observada. Os dados foram avaliados por meio do teste exato de Fisher. Um total de 26 selantes e 26 restaurações foram realizadas. Não houve diferença entre os grupos quanto às características iniciais - idade, sexo, CPOD e ISG. Após um ano, foram avaliados 49 dentes, apresentando taxas de sucesso de 95,8% e 100% nos grupos selante e restauração convencional, respectivamente (p>0,05). Houve uma falha em um dos tratamentos (perda total no grupo selante) observada durante o estudo. A avaliação radiográfica (progressão, inativação, regressão e presença de dentina terciária) não demonstrou diferença entre os grupos. Nenhum dos dentes apresentou progressão de cárie; a regressão foi observada em apenas um caso (grupo do selante) e a presença de dentina terciária foi encontrada em 12,5% da amostra (5 selantes e 1 restauração). Selantes podem ser utilizados como tratamento terapêutico para lesões de cárie incipientes em dentes permanentes, uma vez que impedem a progressão das lesões de cárie, preservando a estrutura do dente, quando comparado ao tratamento restaurador convencional. / There is a significant decrease in the number of viable microorganisms under sealants and restorations and a consequent decrease in caries progression when bacteria are separated from the oral environment. The aim of this randomized controlled clinical trial was to evaluate the efficacy of two treatments strategies: 1) sealing of carious lesions and 2) operative restorative treatment of occlusal carious lesions in permanent teeth. The sample consisted of 52 carious posterior teeth (premolars and molars) from 47 patients aged 8 - 43 years. In all lesions restorative treatment was necessary according to the following current strategies: presence of cavity and impossibility to perform biofilm control. The maximum depth of lesions was halfway through the dentine assessed by bitewing radiograph. The teeth were randomly assigned to test group – sealant treatment or control group - conventional restorative treatment. Baseline caries experience (DMFT) and gingival bleeding index (GBI) was assessed. Bitewing radiographs were performed after 12 months to evaluate the integrity of the restorations and the radiolucent zone (ZR) beneath the sealants/restorations. Outcomes were defined as clinical performance of sealant and restoration and the prevalence of regression, inactivation and progression of carious lesion by radiographic examinations. Presence of tertiary dentine was also evaluated. The data were submitted to Fisher`s exact test. A total of 26 sealants and 26 restorations were performed. There were no differences between the two groups regarding baseline characteristics – age, gender, DMFT and GBI. After one year, 49 evaluations had been performed, showing 95.8% and 100% of success rates in test and control group respectively (p>0.05). There was one therapeutic failure (total loss in the sealant group) observed during the study. No difference in the radiographic evaluation (progression, inactivation, regression and tertiary dentin deposition) was observed between the groups (p>0.05). No teeth showed caries progression; regression was observed in only one case (sealant group) and tertiary dentin was founded in 12.5% of the sample (5 sealants and 1 restoration). Sealants can be used as a therapeutic treatment for incipient carious lesions in permanent teeth, since they prevent the progression of carious lesions, while preserving tooth structure when compared to conventional restorative treatment.
202

Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos / Influence of irradiance on Knoop hardness, degree of conversion and shrinkage of the different composites

Fugolin, Ana Paula Piovezan, 1987- 17 August 2018 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T16:31:27Z (GMT). No. of bitstreams: 1 Fugolin_AnaPaulaPiovezan_M.pdf: 7087256 bytes, checksum: 828f5aed76c8ac133d37deb6cf423e11 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi investigar a influência de diferentes irradiâncias e de energia emitida pelo fotoativador na dureza Knoop, grau de conversão e contração de polimerização de compósitos odontológicos com diferentes partículas de carga. Anéis de latão de 12 mm de diâmetro externo, 8 mm de diâmetro interno e 2 mm altura foram preenchidos com os compósitos Filtek Supreme XT® (ESPE 3M) e Charisma® (Heraeus Kulzer), ambos na cor A2. O aparelho utilizado foi o LED Bluephase G2 (Ivoclar-Vivadent), com tempo de fotoativação de 20 s e irradiância conforme o protocolo: grupos A e D- 300 mW/cm²; grupos B e E- 650 mW/cm² e grupos C e F- 1200mW/cm², sendo n = 5. Depois da polimerização, cada conjunto (matriz e amostra) foi submetido aos procedimentos de acabamento e polimento com lixas de carboneto de silício. A armazenagem foi em estufa a 37ºC por 24 horas, dispostos em recipiente a seco e no escuro. Após armazenagem, as superfícies de topo e base das amostras foram submetidas ao teste de dureza Knoop em durômetro, onde foram efetuadas 5 penetrações em cada região, com carga de 50 gf por 5 s. As amostras submetidas ao ensaio de dureza Knoop foram analisadas em microscopia eletrônica de varredura para verificar o nível de adaptação material-matriz. Por meio do programa UTHSCSA ImageTool foi mensurada a largura das fendas. Para avaliar o grau de conversão outras amostras foram confeccionadas, as quais foram avaliadas pelo FTIR com ATR. Os dados foram submetidos à ANOVA múltiplos fatores e teste de Tukey (5%). Os resultados mostraram que: A dureza Knoop do Filtek Supreme XT foi significativamente maior que do Charisma, independente do local e irradiância. Independente do material e local, as irradiâncias de 1200 mW/cm² e 650 mW/cm² mostraram valores de dureza estatisticamente similares, sendo ambas significativamente maiores aos de 300 mW/cm². Para Charisma houve diferença estatística significante entre topo e base nas irradiâncias de 300 mW/cm² e 650 mW/cm². No Filtek Supreme XT houve diferença estatística significante entre topo e base somente na irradiância de 300 mW/cm². Independente do local e irradiância, o grau de conversão do Charisma foi estatisticamente maior que do Filtek Supreme XT, exceto na irradiância de 650 mW/cm², onde os valores foram estatisticamente similares. No Charisma, a irradiância de 1200 mW/cm² proporcionou grau de conversão significativamente maior que 300 mW/cm² e 650 mW/cm², ambos similares entre si. No Filtek Supreme XT, a irradiância de 1200 mW/cm² proporcionou valor significativamente maior, 300 W/cm² menor e 650 mW/cm² valor intermediário. Independente da irradiância, para Filtek Supreme XT não houve diferença entre topo e base. Para Charisma, 300 mW/cm² e 650 mW/cm² apresentaram diferença estatística significante entre topo e base, sendo que em 1200 mW/cm² não houve diferença estatística significante. Independente da irradiância, a contração do Charisma foi significativamente maior que do Filtek Supreme XT. Independente do material, a contração promovida pelas irradiâncias foi similar. Os resultados deste estudo mostraram que a irradiância influenciou na dureza Knoop e no grau de conversão, não causando efeito na contração dos compósitos. / Abstract: The aim of this study was to investigate the influence of both energy and power density (of different levels) emitted by light curing unit in the Knoop hardness, conversion degree and polymerization shrinkage of dental composites with different types of filler particles. Brass rings of 12mm outside diameter, 8mm internal diameter and 2mm height were filled with the composites Filtek Supreme XT® (3M ESPE) and Charisma (Heraeus Kulzer), both color A2. The light curing unit Bluephase G2 LED (Ivoclar-Vivadent) was used for 20s with irradiance according to the protocol; groups A and D ¿ 300 mW/cm², groups B and E ¿ 650 mW/cm² and groups C and F ¿ 1200 mW/cm². After polymerization, the sets (matrix and sample) were finished and polished with silicon carbide sandpaper and stored for 24 hours at 37°C in dark and dry container. After his period the specimens were evaluated for their hardness in an indenter, where top and bottom surfaces were submitted to five penetrations, with a load of 50gf for 5 s. Scanning electron microscopy (SEM) of these samples was carried out to check the gap between composite and matrix and the extent of crack were measured using the program UTHSCSA ImageTool. FTIR with ATR techniques assessed the degree of conversion of new samples. The data were analyzed by multiple factors ANOVA and Tukey test (p ? 0.05). In the results Filtek Supreme XT showed hardness values significantly higher than those of Charisma, regardless the location and the irradiance. At irradiances of 1200 mW/cm² and 650 mW/cm² showed hardness values statistically similar and significantly higher at 300 mW/cm², regardless the material and the location. Charisma showed a statistically significant difference between top and bottom in the irradiances 300 mW/cm² and 650 mW/cm². Filtek Supreme XT showed significant difference between top and bottom only in the irradiance of 300 mW/cm². The results for degree of conversion showed that, regardless the location and irradiance, Charisma had statistically higher values than Filtek Supreme XT, except for the irradiance of 650 mW/cm², where the values of the composites were statistically similar. At the power density of 1200 mW/cm², Charisma achieved values significantly higher than 650 mW/cm² and 300 mW/cm². At the power density of 1200 mW/cm² Filtek Supreme XT showed the highest conversion values, while at 300 mW/cm² showed the lowest values, and at 650 mW/cm² intermediate values were found. Regardless the irradiance, Filtek Supreme XT showed no difference between top and bottom. Charisma, at 300 mW/cm² and at 650 mW/cm² showed statistically significant difference between top and bottom, and at 1200 mW/cm² the difference was not statistically significant. Charisma showed significantly higher values of contraction than Filtek Supreme XT, regardless the irradiance. Regardless the material, no statistical difference was found for values of contraction for the evaluated irradiances. The findings of this study showed that the power density influenced the hardness and the degree of conversion, but not the contraction. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
203

Efeito da distância de fotoativação e meios de imersão sobre a sorção e a solubilidade de um compósito nanoparticulado / Effect of light curing tip distance and immersion media on the sorption and solubility of a nanofilled composite

Miranda, Diogo de Azevêdo, 1986- 17 August 2018 (has links)
Orientador: José Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T18:06:02Z (GMT). No. of bitstreams: 1 Miranda_DiogodeAzevedo_M.pdf: 1344077 bytes, checksum: 4e28fd76c33592cec253d42d20416b38 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar o efeito de três distâncias de fotoativação (0mm, 3mm e 6mm) e quatro meios de imersão (saliva artifical, Plax FreshMint, Plax Sem álcool e Plax Whitening) sobre a sorção e solubilidade de um compósito nanoparticulado. Os espécimes foram confeccionados em uma matriz de teflon de 6mm de diâmetro por 1mm de profundidade, e o compósito Filtek¿ Z350 (3M ESPE) foi inserido em incremento único e fotoativado por 20 segundos. Para controlar as distâncias de fotoativação, foi utilizado um dispositivo acoplado a um paquímetro digital. Inicialmente foram confeccionadas 15 amostras (n=5) e, em seguida, realizado o teste de Grau de Conversão (GC%). O GC% dos espécimes foi mensurado antes e após fotoativação, através do espectrômetro de raios infravermelhos transformado de Fourier (FTIR). O GC% foi calculado através da razão entre os espectros não-polimerizados e polimerizados do compósito. Para os testes de sorção e solubilidade foram confeccionados 60 espécimes (n=5), de acordo com as variáveis distâncias de fotoativação e meios de imersão. As amostras foram armazenadas em um dissecador com sílica em gel até a obtenção de uma massa inicial estável (m1). Após estabilização da massa inicial, o diâmetro e a espessura foram aferidos em quatro pontos eqüidistantes utilizando um paquímetro digital e, em seguida, calculado o volume individual (V) de cada amostra. Em seguida, as amostras foram imersas duas vezes ao dia, durante dois minutos nos enxaguatórios por 30 dias. Durante o intervalo de 12 horas, as amostras permaneciam imersas em saliva artificial. Por fim, as amostras foram retiradas das soluções, pesadas (m2) e, em seguida, colocadas no dessecador até a obtenção de uma massa final estável (m3). A sorção (Sp) e solubilidade (SI) foram calculadas através das seguintes fórmulas: Sl = m1-m3/V e Sp= m2-m3/V. Os dados de CG% foram analisados por meio de análise de variância (ANOVA) em esquema de parcelas subdivididas e as comparações múltiplas foram feitas pelo teste de Tukey, considerando o nível de significância de 5%. Os resultados mostraram que independente da distância de fotoativação, a superfície base teve os menores valores de GC% e, que somente quando fotoativado a 6mm de distância, os valores de GC% foram estatisticamente inferiores quando comparados as demais distâncias. Para sorção, os dados foram analisados por ANOVA two way e teste de Tukey, considerando o nível de significância de 5%. Quando fotoativado a 3mm de distância, o Plax Whitening diferiu dos demais enxaguatórios. Durante a fotoativação a 6mm de distância, observou-se diferença estatística em relação as demais distâncias, entretanto não ocorreu diferença estatística entre os enxaguatórios. Os dados de solubilidade foram analisados pelos testes não paramétricos de Kruskal Wallis e Dunn, com nível de significância de 5%. Para todas as distâncias e soluções, os valores foram negativos. Pode-se concluir que o GC% e a sorção do compósito foram influenciados quando fotoativados a 6mm, entretanto, não houve diferença estatística entre os enxaguatórios. Quanto a solubilidade, os valores negativos sugerem que o fenômeno foi mascarado pela sorção / Abstract: The aim of this study was to evaluate the effects of three curing tip distances (0mm, 3mm and 6mm) and four immersion media (artificial saliva, Plax FreshMint, Plax Alcohol-Free and Plax Whitening) on the sorption and solubility of nanofilled composite.The specimens were prepared in a Teflon matrix of 6mm Ø and 1mm height, and Filtek ¿ Z350 (3M ESPE) was inserted in one increment and light cured for 20 seconds. To control the curing tip distances, we used a device coupled to a digital caliper. Initially 15 samples were prepared (n = 5) and then performed the test degree of conversion (DC%). The DC% of the specimens was measured before and after curing, by ray spectrometer, Fourier transform infrared (FTIR). The GC% was calculated as the ratio of the spectra non-polymerized and polymerized composite. For the sorption and solubility tests were prepared 60 specimens (n = 5), according to the variable distances polymerization and immersion media. The samples were stored in a desiccator with silica gel to obtain a stable initial mass (m1). After stabilization of the initial mass, diameter and thickness were measured at four equidistant points by using a digital caliper and then calculated the individual volume (V) of each sample. Then the samples were immersed twice a day for two minutes in mouthrinses for 30 days. During the 12 hours, the samples were immersed in artificial saliva. Finally, samples were taken from the solutions, weighed (m2) and then placed in a desiccator until obtaining a stable final mass (m3). Sorption (Sp) and solubility (SI) were calculated by the following formula: Sl=m1-m3/V and Sp=m3-m2/V. Data from GC% were analyzed by analysis of variance (ANOVA) in split plots and multiple comparisons were made by Tukey test, considering the significance level of 5%. The results showed that regardless of the distance of curing, the bottom surface has the lowest GC%, and that cured only when the distance of 6mm, GC% values were significantly lower when compared with the other distances. For sorption, the data were analyzed by two-way ANOVA and Tukey test, considering the significance level of 5%. When photoactivated to 3mm away, Plax Whitening differed from the others mouthrinses. During polymerization the 6mm away, there was statistical difference from the other distances, but no statistical difference between the mouthrinses. The solubility data were analyzed by nonparametric Kruskal Wallis and Dunn, with a significance level of 5%. For all distances and solutions, the values were negative. It can be concluded that the GC% and sorption properties were influenced when photoactivated to 6mm, however, there was no statistical difference between rinses. As the solubility negative values suggest that the phenomenon was masked by sorption / Mestrado / Dentística / Mestre em Clínica Odontológica
204

Resistência à degradação biológica, química e mecânica de materiais resinosos nanoparticulados / Resistance to degradation biological, chemical and mechanical resin materials nanofillers

Paula, Andreia Bolzan de 18 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:24:32Z (GMT). No. of bitstreams: 1 Paula_AndreiaBolzande_D.pdf: 4070151 bytes, checksum: 59b6aec78bd6931d2430106db002b0dc (MD5) Previous issue date: 2011 / Resumo: O avanço da Odontologia Estética tem sido impulsionado pela introdução de novos materiais restauradores, tais como os nanoparticulados, os quais têm demonstrado bom desempenho mecânico e excelentes propriedades ópticas. Entretanto, deve-se considerar que os materiais restauradores estão constantemente sujeitos aos desafios térmicos, mecânicos e químicos na cavidade bucal que podem acarretar danos a estes materiais, num processo denominado degradação. Dessa forma, os objetivos nesta tese, composta por 2 capítulos, foram: (1) avaliar a morfologia e a rugosidade de superfície de materiais nanopartículados quando submetidos a biodegradação e abrasão por escovação e (2) avaliar os efeitos do armazenamento em diferentes soluções simuladoras da dieta ácida na rugosidade e dureza de superfície de materiais restauradores. No capítulo 1, vinte espécimes obtidos de cada material (Vitremer, Ketac N100, TPH Espectrum e Filtek Z350) foram divididos em dois grupos de armazenamento (n=10): umidade relativa e bioflime de S. mutans. Após sete dias, todos os espécimes foram lavados em ultrassom para a mensuração da rugosidade de superfície (Ra) e avaliação em microscopia eletrônica de varredura. Seguidamente, o teste de abrasão por escovação foi conduzido no grupo biodegradado e os espécimes reavaliados. Os dados foram submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey (p<0.05). Após a biodegradação o ketac N100 apresentou os maiores valores de Ra. Quando as amostras biodegradadas foram submetidas à abrasão por escovação, o compósito Z350 apresentou os menores valores de Ra. No capítulo 2, foram confeccionados espécimes (5mm-diâmetro; 2mm-espessura), dos materiais utilizados no Capítulo 1, os quais foram divididos em 4 grupos (n=30). Após 24h, foram realizados os procedimentos de acabamento e polimento e os testes de dureza Knoop (KHN) e rugosidade de superfície. Seguidamente, cada grupo foi dividido em 3 subgrupos (n=10) de acordo com o meio de armazenagem: saliva artificial, suco de laranja e Coca-Cola®. A rugosidade de superfície e dureza Knoop dos espécimes foram reavaliadas após 30 dias de armazenamento e os dados submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey (p<0,05). Os compósitos apresentaram menor Ra e maior KHN que os materiais ionoméricos em todas as situações estudadas. Após a degradação química, a diminuição significativa da KHN foi observada para todos os materiais, enquanto o aumento da Ra foi observado nos materiais ionoméricos armazenados em Coca-Cola® e suco de laranja. O compósito Z350 apresentou valores similares de KHN após a erosão qualquer que fosse a solução de armazenamento. Para os outros materiais, a Coca-cola e o suco de laranja provocaram maiores reduções nos valores de KHN. Com base nos resultados obtidos pode-se concluir que nanopartículas incorporadas aos materiais estudados exerceram influência significativa para a obtenção de maior resistência frente à degradação biomecânica. No entanto, a presença de nanopartículas não influenciou na resposta à erosão quanto à rugosidade e dureza Knoop / Abstract: Esthetic Dentistry has increasingly advanced with the introduction of new restorative dental materials, such as nanofilled materials, which have demonstrated better mechanical behavior and excellent optical properties. However, restorative materials are constantly subjected to thermal, mechanical and chemical challenges in the oral cavity that leads to damage of these materials in a process called degradation. The objectives of this dissertation were to evaluate: (1) the morphology and surface roughness of nanofilled materials subjected to biodegradation and brushing and (2) the effects of storage in different acid diet simulating solutions on roughness and surface hardness of resin based restorative materials. In the study 1, twenty specimens obtained from each material (Vitremer, Ketac N100, TPH Espectrum e Filtek Z350) were divided into two storage groups (n=10): relative humidity (control) and Streptococcus mutans biofilm (biodegradation). After 7 days of storage, roughness values (Ra) and micrographs by Scanning Electron Microscopy (SEM) were obtained. In a second experimental phase, the specimens previously subjected to biodegradation were abraded via toothbrushes (mechanical degradation). Next, these specimens were washed, dried, and reassessed by roughness and SEM. The data were submitted to repeated measures three-way ANOVA and Tukey's tests (p<0.05). After biodegradation, Ketac N100 presented the highest Ra values. Concerning bio plus mechanical challenges the nano composite Filtek Z350 exhibited the best resistance to cumulative challenges proposed. In the study 2, disc-shaped specimens (5mm-diameter; 2mm-thick) of the same materials used on study 1 were obtained according to the manufacturers' instructions, thereby forming four groups (n=30). After 24h, polishing procedures were performed and initial hardness(KHN) and roughness(Ra) measurements were realized. Next, each group was divided into three subgroups (n=10) according to storage media: artificial saliva, orange juice and Coca-Cola®. After 30 days of storage, the specimens were reevaluated about Ra and KHN. Data were tested for significant differences by three-way ANOVA and Tukey (p<0.05). It was observed that composites presented lower roughness values and higher hardness values than ionomeric materials under all storage conditions. After erosion, KHN of all experimental samples dropped significantly, while only the Ra of ionomeric materials increased, depending on the media, with a markedly negative impact of Coca-Cola® and orange juice. There was not difference among storage media for Filtek Z350 regarding to KHN values. Based on the results it can be concluded that nanofillers incorporated into the studied materials was important to obtain greater resistance against biomechanics degradation. However, the presence of nanofillers did not influence the surface roughness and Knoop hardness when the tested materials underwent to erosion / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
205

Avaliação biomecânica de pré-molares superiores restaurados com diferentes monômeros resinosos / Biomechanical evaluation of pre-molars restored with different monomers resins

Barreto, Bruno de Castro Ferreira 18 August 2018 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T01:00:44Z (GMT). No. of bitstreams: 1 Barreto_BrunodeCastroFerreira_D.pdf: 19459123 bytes, checksum: 7994f36259737060feeacf56adfc4410 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar a viabilidade da utilização de um método de geração de modelo tridimensional de pré-molar superior, com capacidade de representar as tensões de contração de polimerização por meio de analogia térmica com aplicabilidade ao método de elementos finitos. Após isto, neste trabalho avaliou-se o comportamento biomecânico de pré-molar superior enfraquecido, restaurado com dois tipos de monômeros resinosos por meio de análise por elementos finitos comparando ao dente hígido. Para geração do modelo 3D foi selecionado primeiro pré-molar superior hígido. O dente escolhido foi mapeado com scanner de contato 3D (Modela, Roland) e, logo após, o esmalte foi degradado com ácido clorídrico-10%, para a realização da digitalização da imagem da dentina coronária. Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido vestíbulo-palatino e realizada a digitalização do espaço negativo referente à polpa. Os arquivos com extensão *.STL (steriolitografia) foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies complexas não regulares (NURBS). Os modelos foram exportados para o programa de elementos finitos (Ansys Workbench v12), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 9 modelos, sendo um do dente hígido e 8 modelos de acordo com os 3 fatores em estudo: tipo de perda estrutural em dois níveis: com e sem socavamento de cúspide, tipo de monômero resinoso em dois níveis: silorano e metacrilato, e aplicação de carregamento de compressão em dois níveis: com carregamento e sem carregamento. Os resultados foram analisados pelo critério de tensão máxima principal e von Mises. Os resultados obtidos mostraram consonância com a literatura, e a observação do estudo comprovou que o uso do modelo geométrico 3D com analogia térmica para contração de polimerização é adequado para a análise por elementos finitos. Concluiu-se que a presença do socavamento apresentou aumento da concentração de tensões nas estruturas dentárias, principalmente quando associado ao uso da resina de metacrilato; o tipo de monômero resinoso e a diferença de contração volumétrica influenciaram na concentração das tensões no material, na interface e no substrato, e que o carregamento compressivo influenciou os valores de tensão / Abstract: The aim of this study was to evaluate the feasibility of using a method of generating three-dimensional model of maxillary premolar tooth, with ability to represent the tensions of polymerization shrinkage through thermal analogy with applicability to the finite element method. After that, this study evaluated the biomechanical behavior of weakened premolar, restored with two types of resin monomers through finite element analysis compared to healthy teeth. To generate the 3D model was selected first premolar healthy. The tooth was chosen mapped contact with scanner (3D Models, Roland) and, soon after, the enamel was degraded with hydrochloric acid-10%, to perform the scan image of the coronal dentin. To map the volume pulp, dentin was sectioned longitudinally in the buccopalatal and performed scanning the negative space on the pulp. The files with extension *. STL (steriolitography) were exported to Bio-CAD program (Rhinoceros-3D). Volumes of each tooth structure and restorative techniques were generated through the association of non-regular complex surfaces (NURBS). The models were exported to the finite element program (Ansys Workbench v12), which had undertaken the process of mesh size, insertion of the mechanical properties and boundary conditions. 9 models were generated, one of the healthy tooth and eight models according to three factors studied: type of structural loss at two levels: with and without undermining the cusp, type of resin monomer into two levels: Silorane and methacrylate, and application of compression loading on two levels: with and without loading. The results were analyzed by the criterion of maximum principal stress and von Mises. The results showed agreement with the literature, and observation of the study showed that use of the 3D geometric model with analogy to thermal polymerization shrinkage is suitable for finite element analysis. It was concluded that the presence of undermining showed an increase in stress concentration in the dental structures, especially when associated with the use of methacrylate resin, type of resin monomer and the difference in shrinkage influence the concentration of stresses in the material, in the interface and substrate, and the compressive loading influenced the values of tension / Doutorado / Dentística / Doutor em Clínica Odontológica
206

Análise de sistemas de fixação resinosos = por meio de nanoinfiltração, microdureza e microcisalhamento / Analisys of resin luting systems through nanoleakage

Prieto, Lúcia Trazzi, 1984- 18 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T10:11:30Z (GMT). No. of bitstreams: 1 Prieto_LuciaTrazzi_M.pdf: 18594558 bytes, checksum: 8b9915e7be1b8a88b1ea31cad84b6133 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste estudo "in vitro" foi avaliar dureza Knoop, resistência ao microcisalhamento e o padrão de nanoinfiltração de cimentos resinosos em esmalte dental. Assim, foram utilizadas 92 coroas bovinas que tiveram o esmalte vestibular planificado onde se cimentou blocos de cerâmica IPS Empress Esthetic, de acordo com os grupos experimentais: Variolink/Excite DSC (Ivoclar-Vivadent), Panavia F/Clearfil SE Bond (Kuraray), RelyX ARC/Scotchbond Multi-uso Plus (3M/ESPE), Filtek Flow/Single Bond (3M/ESPE). Para o teste de microcisalhamento (n=10), dois cilindros cerâmicos com 1 mm de diâmetro e 3 mm de altura foram cimentados sobre o esmalte, sendo que um dos cilindros foi submetido ao teste 24 horas após a cimentação, e o outro submetido à ciclagem térmica (2000 ciclos), e posterior avaliação da resistência à união em máquina de ensaio universal. Para a análise da microdureza (n=10), foi simulada a cimentação de um disco cerâmico cor A3 (5 mm de diâmetro e 1,2 mm de espessura). A dureza foi avaliada diretamente sobre o cimento, com 16 indentações por amostra. Para a avaliação do padrão de nanoinfiltração (n=3) as amostras foram infiltradas com nitrato de prata e colocadas em solução reveladora para análise em MEV. Os dados do microcisalhamento foram submetidos à análise de variância dois fatores e teste de Tukey (?=0,05). O RelyX ARC (29,7MPa) apresentou os maiores valores de resistência à união comparados aos demais sistemas, Panavia F (17,7MPa) e Variolink (15,3MPa) foram estatisticamente semelhantes entre si e superiores à Flow (8,7MPa), que apresentou os valores mais baixos. Os dados da microdureza foram submetidos à análise estatística em esquema inteiramente casual e teste de Tukey (?=0,05). Em relação à microdureza, Panavia F (49,7 KHN) obteve os maiores resultados, sendo que ARC (39,6 KHN) e Variolink (43,8 KHN) apresentaram resultados intermediários, semelhantes tanto ao Panavia F, quanto à resina composta Flow (35,0 KHN), que mostrou os menores valores. A resina composta flow não apresentou nanoinfiltração, já a maior porcentagem de nanoinfiltração foi apresentada pelo Variolink. Concluiu-se que a flow quando usada como agente de fixação para cerâmica odontológica apresentou os menores valores de resistência e dureza, porém com uma camada híbrida sem porosidades formada através do sistema adesivo Single Bond / Abstract: During the cementing indirect restorations procedure using resin luting systems, polymerization is essential for an effective clinical outcome of success. The aim of this in vitro study was to evaluate the Knoop hardness (KHN), microshear bond strength (MSBS) and nanoleakage pattern of resin cements and flowable resin to dental enamel. Ninety-two enamel bovine incisors were used in this study, which were planered and cemented blocks of IPS Empress Esthetic, according to the experimental groups: Variolink / Excite DSC (Ivoclar-Vivadent), Panavia F / Clearfil SE Bond (Kuraray) RelyX ARC / Scotchbond Multi-Purpose Plus (3M/ESPE), Filtek Flow / Single Bond (3M/ESPE). For microshear test (n = 10), two ceramic cylinders 1 mm in diameter and 3 mm in height were adhered to the enamel surface, and one of the cylinders tested, 24 hours after cementation, and the other subjected to cycling thermal (2000 cycles) and subsequent evaluation of bond strength in a universal testing machine. For the microhardness analysis (n = 10) simulated the cementation of a ceramic disc color A3 (5 mm in diameter and 1.2 mm thick). The hardness was measured directly on the cement, with 16 indentations for each sample. For assessing the pattern of nanoleakage (n = 3) samples were infiltrated with silver nitrate and placed in developing solution for SEM analysis. The obtained data of microshear were submitted to two-factor ANOVA and Tukey test (? = 0.05). For RelyX ARC (29,7MPa), the MSBS showed higher bond strength when compared to other luting systems, Panavia F (17,7MPa) and Variolink (15,3MPa) showed similar MSBS behavior between each other, therefore higher than the flowable composite (8,7MPa), which had the lowest values. The obtained data of microhardness were submitted to statistical analysis in outline entirely casual and Tukey test (a=0,05). In relation to the KHN, Panavia F (49,7 KHN) showed higher results, however it was statistically similar to RelyX ARC (39,6 KHN) and Variolink (43,8 KHN), the composite resin to flow, which was lower. The flowable composite Filtek (35,0 KHN), showed no silver nitrate uptake, but the largest percentage of nanoleakage was presented by Variolink. It was concluded that flow resin when used as fixing agent for dental ceramic showed the lowest values of bond strength and Knoop hardness, but a hybrid layer without porosity that was formed by Single Bond / Mestrado / Dentística / Mestre em Clínica Odontológica
207

Analise longitudinal da resistencia a tração, da nanoinfiltração e do padrão morfologico da camada hibrida de sistemas adesivos autocondicionantes aplicados a dentina humana higida ou afetada por carie / Long-term analysis of microtensile, nanoleakage and morphologic pattern of hybrid layers promoted by different self-etching bonding agents to normal and caries-affected human dentin

Erhardt, Maria Carolina Guilherme 27 June 2005 (has links)
Orientadores: Luiz Andre Freire Pimenta, Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T22:40:09Z (GMT). No. of bitstreams: 1 Erhardt_MariaCarolinaGuilherme_D.pdf: 6301805 bytes, checksum: 90041cc31702b631248ac0b326fef07e (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo in vitro foi determinar a durabilidade da interface adesiva emdentina normal (DN) ou afetada por cárie (DAC) promovida por um sistema adesivo simplificado convencional (AdperScotchbond1/ SB)e dois sistemas autocondicionantes de dois passos(Clearfil Protect Bond / PBe AdheSE/ AD), após24 horas(24h)ou 6 meses(6me)de imersão em água.Para o teste de microtração,90 molares humanos cariados foram selecionados. A superfície dentinária foi exposta através de seccionamento com disco duplo diamantado e polimento com lixas de carbeto de silício, deixando uma área central de DAC. Osdentes foram aleatoriamente divididos em 3 grupos para que recebessem a aplicação de um dos 3 sistemas adesivos, de acordo com a recomendação dos fabricantes.Blocos de compósito Tetric Ceram com altura de 4 mm foram incrementalmente confeccionados,e após 24 h de armazenagem em água destilada a 37 oC, os dentes foram seriadamente seccionados em fatias de 1,0mm de espessura paralelas ao longo eixo dental.Em seguida,dispositivos em forma de ampulheta foram confeccionados com pontas diamantadas de granulação fina em alta rotação,com área adesiva final de aproximadamente1,0 mm2, que continham DN ou DAC. Os espécimes foram armazenados em água destilada por 24h ou 6me. Decorrido este período, os espécimes foram fixados individualmente em um dispositivo de microtração (Bencor-T),acoplado em máquina de ensaio universal (Instron), para teste à 0,5 mm/min.Após o teste, a porção dentinária dos espécimes fraturados foi avaliada em um microdurômetro do tipo Knoope também observadas em microscópio eletrônico de varredura(MEV). As médias de resistência de união foram submetidos aos testes de análise de variância (ANOVA 3 fatores),StudentNewmanKeulse t de Student(p < 0,05). Cinqüenta e quatro molares cariados adicionais foram preparados da mesma maneira supradescrita. Após 24 h de armazenagem em água destilada a 37 oC,os dentes foram seccionados em fatiasde 1,0mm de espessura paralelas ao longo eixo dental. As atias foram também armazenadas em água destilada por24h ou'6me. Os espécimes de nanoinfiltração foram imersos em solução e nitrato de prata amoniacal por 24 h, lavados abundantemente imerso sem solução foto reveladora por 8 h, sobre luz fluorescente. Após o tempo de armazenagem, fatias foram recobertas com carbono para observação em MEV. Já os espécimes de tricrômico de Masson foram manualmente polidos até que apresentassem espessura média de 3 - 5 µm, paraquefos sem corado sde acordo com as indicações da técnica histológica e visualizados em microscópio óptico. Os valores médios de microtração(MPa),foram:DN/SB/24h=42,63; DN/PB/24h= 39,18; DN/AD/24h= 28,19; DN/SB/6me= 38,43; DN/PB/6me= 39,49;DN/AD/6me=27,90;DAC/SB/24h=34,49;DAC/PB/24h=28,68;DAC/AD/24h=24,20;DAC/SB/6me= 27,76;DAC/PB/6me=24,48;DAC/AD/6me=17,24.Tantoem DNquantoem DAC,após 24h ou 6me de imersão,os sistemas SB e PB apresentaram os maiores valores de resistência de união. De uma maneira geral, maiores valores de união foram obtido sem DN, comparado à DAC.Os sistemas adesivos autocondicionantes apresentaram maior estabilidade após 6 me de armazenamento / Abstract: The purpose of this study was to investigate the durability of resin-dentin bonds to sound (SD) and caries-affected dentin(CAD)using an total-etch(Adper Scotchbon1d/ SB)or two self-etch bonding systems(Clearfil Protect Bond/ PBandAdheSE/ AD)bonding agents,after24 hours(24h)or 6 months(6mt)of storage in water.For the microtensile bond strength (Thepurposeof thisstudywasto investigatethedurabilityof resin-dentinbondstosound(SD)and caries-affected dentin(CAD)using an total-etch(AdperScotchbon1d/ SB)or two self-etch bonding systems(ClearfilProtectBond/ PBandAdheSE/ AD)bonding agents,after24hours(24h)or 6 months(6mt)of storage in water.For the microtensile bond strength(jJTBSe) valuation 90 extracted carious human molars were ground flat oclusally with wets and(SiC)papers,leaving a central region of CAD dentin surrounded by ND.The teeth were randomly assigned into three groups,according to he bonding system used. All bonding systems were applied according to manufactures instructions. Resin composite (TetricCeram) build-ups were made incrementally. After storage in distilled water at 37°C for 24 h, teeth were erially sectioned into1.0mms labs,and trimmed to yield a 1.0mm2 bonded area that contained either NDor CAD.Experimental hlourglas specimens were stored in water for 6 mt. Specimens that had been store din water for 24 hwere use das controls.Specimens were individually attached to a microtensile device(Bencor-T) which was coupled to an Instron machine and tested at a crosshead speed of 0.5 mm/min.The dentin surfaces of the fractured specimens were evaluated using Knoop microhardness test and observed by scanning electron microscopy( SEM).Data were analyzed by ANOVA,Student Newman Keulsandt Student multiple comparison tests (p < 0.05). Additional 54 extracted carious human molars were prepared for nanoleakage and Masson'strichrom evaluation as described above. After storage in distilled water at 37°Cfor24h, teeth were serially sectioned into1.0mm slabs that contained NDor CAD.Slabs were store dinwater for 24 h or 6 mt.The specimens for nanoleakage were immersed in ammoniacal silver nitrate for 24 h, rinsed thoroughly and placed in photo developing solution for 8 h under fluorescent light. Slabs weres putter-coated with carbon and observed under SEM.Trichrome specimens were manually polished to 3 - 5 µm thin sections of the adhesive/denti interface and stained with the histologica dyes.Stained thin sections from each prepared tooth were imaged with optical microscopy. The µTBS mean values obtained(MPa)were:ND/SB/24h4=2.63;ND/PB/24h= 39.18; ND/AD/24h=28.19; ND/SB/6mt=38.43; ND/PB/6mt=39.49; ND/AD/6mt=27.90; CAD/SB/24h3=4.49;CAD/PB/24h2=8.68;CAD/AD/24h2=4.20;CAD/SB/6m2t=7.76;CAD/PB/6mt= 24.48;CAD/AD/6mt= 17.24.SBandPB presented the higher µTBS values,irrespective of dentin type.Regarding bond strengths obtained with all bonding systems evaluated, it could be always observed higher mean values for ND.Self-etching bonding agents presented a higher stability after 6 mt water immersion / Doutorado / Dentística / Doutor em Clínica Odontológica
208

Efeito de tecnicas de fotoativação na adaptação marginal e dureza Knoop de um composito restaurador fotoativado por tres fontes de luz / The effect of photoactivation technics in the marginal adaptation and Knoop hardness of a restorative when used three light curing units

Alves, Eliane Bemerguy 14 September 2005 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T09:04:33Z (GMT). No. of bitstreams: 1 Alves_ElianeBemerguy_D.pdf: 642464 bytes, checksum: a986353a680e6d427281d2a4f0c5d3e7 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a adaptação marginal e a dureza Knoop da resina Filtek Z250, cor A2 (3M-ESPE) utilizada para restaurar 90 cavidades, com margens em dentina, confeccionadas na face vestibular de incisivos bovinos, empregando três técnicas e três métodos de fotoativação. As cavidades foram padronizadas com dimensões de 3mm no sentido mesio-distal; 3mm no sentido inciso-cervical e 1,5mm de profundidade. Os grupos, com 10 restaurações cada, foram divididos de acordo com a técnica de fotoativação: direta; transdental ou mista, e método de fotoativação, que correspondem a variações na fonte de luz: halógena com 600mW/cm² (XL 2500/3M), arco de plasma de xenônio com 1340mW/cm² (Apollo 95E/DMD) e LED com 500mW/cm² (Ultrablue IS/DMC). Os tempos para cada etapa de fotoativação foram estabelecidos em 20s para os aparelhos fotoativadores Ultrablue IS e XL 2500 e 9s para o Apollo 95E. A análise da adaptação marginal foi realizada em fotos digitais, obtidas das superfícies das restaurações, após 24 horas de armazenagem, polimento padronizado e pigmentação com vermelho ácido a 1% em propileno glicol (Caries Detector- Kuraray). Foi utilizado o programa analisador de imagens, UTHSCSA - Image Tool, tendo como referência a medida de 1mm de um paquímetro digital (Mitutoyo, Japão) escaneado junto com cada restauração. As medidas de dureza Knoop foram obtidas no topo e na base da restauração, usando o microdurômetro HMV 2 (Shimadzu-Japão) com carga de 50 gramas atuando por 15 segundos. Em cada corpo-de-prova foram feitas seis endentações. Os dados foram submetidos à Análise de Variância e as médias comparadas pelo teste de Tukey (5%) e mostraram que independente do tipo de unidade fotoativadora, o emprego da técnica mista reduziu o percentual de fendas entre o material restaurador e o dente, determinando melhor adaptação marginal em relação à técnica direta, sendo que a técnica transdental não diferiu estatisticamente das demais. A adaptação marginal não foi influenciada pelas diferentes unidades de fotoativação utilizadas neste estudo, quando comparadas dentro da mesma técnica. A técnica de fotoativação direta apresentou as maiores médias de dureza em relação à mista e transdental, sendo que a transdental apresentou os menores valores de dureza. Independente da técnica de fotoativação empregada, o aparelho LED (Ultrablue IS) apresentou os maiores valores de dureza em relação ao Apollo 95E. Nenhuma diferença estatística foi observada nos valores de dureza Knoop entre os aparelhos LED e XL 2500 e XL 2500 e Apollo 95E / Abstract: The aim of this study was to evaluate marginal adaptation and Knoop hardness of the resin Filtek Z250 A2 (3M-ESPE). Ninety cavities, with margins in dentine, in the vestibular face of incisive bovine teeth were restored using three techniques and three photoactivation methods. The cavities were standardized with dimensions: 3mm mesio-distal; 3mm incisive-cervical, and 1.5mm deep. The groups, with 10 restorations each, were divided according to the photoactivation technique: direct; transdental or mixed, and method of photoactivation that correspond to variations in the light source: halogen light with 600mW/cm² (XL 2500/3M), xenon plasma arc with 1340 mW/cm² (Apollo 95E/DMD) and LED with 500mW/cm² (Ultrablue IS/DMC). The periods for each photoactivation stage were established in 20s for the units Ultrablue IS and XL 2500 and 9 s for the Apollo 95E. Marginal adaptation analysis was carried out in digital photografy, obtained from the surfaces of restorations, 24 hours after storage, with standard polish and with red acid pigmentation at 1% in propylene glycol (Cáries Detector - Kuraray). The program image analyzer, UTHSCSA - Image Tool was used , having as reference the measure of 1mm of a digital caliper (Mitutoyo, Japan) scanned with each restoration. The measures of Knoop hardness were obtained on the top and on the base of the restoration, using the microhardness unit HMV 2 (Shimadzu-Japan) with load of 50 grams for 15 seconds. In each specimen were made six indentations. The data were submitted to the Analysis of Variance and the averages compared by Tukey's test (5%) and showed that independent of the type of photoactivating unit the use of the mixed technique reduced the percentile of gaps between the restoring material and the tooth, determining better marginal adaptation in relation to the direct technique. The transdental technique did not differ statistically from the others. The marginal adaptation was not influenced by the different photoactivation units used in this study, when compared inside the same technique. The technique of direct photoactivation showed the highest averages of hardness in relation to the mixed and transdental ones, and the transdental presented the lowest hardness values. Independent of the photoactivation technique used, the Ultrablue IS nit presented the highest hardness values in relation to Apollo 95E. No statistical difference was observed on hardness values between the units Ultrablue IS and XL 2500 and XL 2500 and Apollo 95E / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
209

Investigação na resitencia da união de sistemas adesivos dentarios irradiados com diferentes radiações ionizantes / Investigation of bond strength of dental adhesive systems irradiated with ionizing radiations

Cruz, Adriana Dibo da 12 August 2018 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:59:29Z (GMT). No. of bitstreams: 1 Cruz_AdrianaDiboda_D.pdf: 5672004 bytes, checksum: ac1f74246e4d3453193616e0b3d5a093 (MD5) Previous issue date: 2009 / Resumo: No presente estudo, materiais adesivos com diferentes modos de aplicação foram submetidos à ação de radiações ionizantes de diferentes energias com o objetivo de verificar a resistência adesiva após irradiação, por meio do ensaio de microcisalhamento, avaliando o padrão de fratura, considerando se as radiações utilizadas podem ser agentes externos capazes de causar degradação da união adesiva. Após aprovação do projeto pelo comitê de ética em pesquisa (protocolo:032/2007), 60 dentes humanos tiveram as coroas seccionadas no sentido mesiodistal, e incluídas em bloco de resina epóxi. As coroas foram lixadas para exposição da dentina média obtendo 120 corpos de provas. Os corpos de prova foram divididos em 3 grupos (n=40), de acordo com os sistemas adesivos usados: SB (Adper ¿ Single Bond Plus), CB (Clearfil¿ SE Bond) e AP (Adper¿ Prompt¿ Self-Etch). Os adesivos foram aplicados em dentina e fotoativados usando LED (Lec 1000, MMoptics, 1000mW/cm2). Sobre as áreas adesivas foram colocados moldes de elastômero (0,5mm de espessura por 1,2mm de diâmetro) com três orifícios que foram preenchidos com resina composta (Filtek¿ Z-250) fotoativada por 20s. Cada grupo foi subdividido em 4 (n=10): GC= grupo controle que não foi irradiado; UV= grupo irradiado com ultravioleta; RXD= grupo irradiado com raios-X de energia para o diagnóstico; e RXT= grupo irradiado com raios-X de energia para terapia. Após irradiação foram realizados testes de microcisalhamento (Instron Inc., modelo 4411) para a avaliação da resistência adesiva, e em seguida foram avaliados os modos da fratura das amostras, classificando-os com 5 escores: 1- fratura adesiva; 2- fratura mista com 75% de exposição dentinária, 3 -fratura mista com 50% de exposição dentinária, fratura mista com 25% de exposição dentinária, e fratura coesiva. Os resultados foram submetidos à ANOVA com os testes de Tukey, Dunnett, Kruskal-Wallis e Dunn ( =0,05). As diferentes radiações ionizantes não causaram alterações na resistência da união dos adesivos CB e AP; somente o adesivo SB exibiu aumento na resistência da união após a exposição com UV (p=0,0267). A UV também alterou os padrões de fratura do adesivo SB (p=0,0000). As alterações na resistência da união adesiva e no padrão de fratura não foram degradantes, mas dependeram tanto da energia das radiações ionizantes como do modo de aplicação dos adesivos. Assim as radiações ionizantes não podem ser consideradas como agentes externos capazes de causar degradação nos materiais adesivos estudados / Abstract: In the present study, adhesive materials with different application types were exposed to ionizing radiations of varying energy with the objective to verify by means of microshear and failure mode test the bond strength after irradiation trying to determine whether the used radiations could be external agents able to degrade the adhesive bond. After approbation of this project by the Ethical Committee for Human Research (protocol number 032/2007), 60 human teeth had its crowns sectioned mesio-distally and then were included into block of epoxy resin. The crowns were sanded to show the medium dentin and to obtain 120 specimens. The specimens were divided into 3 groups (n=40), according to the adhesive systems used: SB (Adper¿ Single Bond Plus), CB (Clearfil¿ SE Bond) and AP (Adper¿ Prompt¿ Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000mW/cm2). Onto the bonding areas were placed customized elastomer molds (0.5 mm-thickness by 1.2mm-diameter) with three orifices which were filled with composite resin (Filtek¿ Z-250) photoactivated during 20s. Each group was subdivided into 4 subgroups (n=10): GC=control group without irradiation; UV=group irradiated with ultraviolet radiation; RXD=group irradiated with diagnostic radiation-X; RXT=group irradiated with therapeutic radiation-X. After irradiation the microshear tests were carried out (Instron Inc., model 4411) to evaluate the adhesive bond, and afterwards the modes of failure of the specimens were evaluated and classified using 5 scores: 1=adhesive failure, 2=mixed failure with 75% dentin exposed; 3=mixed failure with 50% dentin exposed; 4=mixed failure with 25% dentin exposed; 5=cohesive failure. The results were submitted to ANOVA by the Tukey, Dunnett, Kruskal-Wallis and Dunn test ( =0.05). No changes in bond strength of CB and AP were observed after application of the different radiations; only SB showed an increase in bond strength after UV (p=0.0267) irradiation. UV also changed the failure patterns in SB (p=0.0000). The changes in the adhesive bond and in the mode of failure did not show degradation, but were dependent of both the energy of ionizing radiation and the way of adhesive application. Thus, the ionizing radiation cannot be considered an external agent able to cause degradation in the studied adhesive materials / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
210

Morfologia da superficie e resistencia da união de ceramica IPS Empress Esthetic submetida a diferentes tratamentos / Bond strenght and surface/interface morphology of luting polymers and glass ceramic etched for different periods

Naves, Lucas Zago, 1981- 13 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Carlos Jose Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:11:57Z (GMT). No. of bitstreams: 1 Naves_LucasZago_M.pdf: 3732245 bytes, checksum: f19061d71b96dbce2d54cda8b37f2ba9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a morfologia de superfície e resistência de união ao microcisalhamento entre a cerâmica reforçada por leucita IPS Empress Esthetic (Ivoclar- Vivadent) e o cimento resinoso Variolink II (Ivoclar-Vivadent), em diferentes tempos de condicionamento da cerâmica, com e sem aplicação do adesivo após o uso do silano. Setenta e dois discos cerâmicos (6mm de diâmetro x 2mm de espessura) foram confeccionados, embutidos em resina e divididos em 12 grupos (n=6), definidos pelo tempo condicionamento com ácido fluorídrico 10% e aplicação ou não de adesivo após o uso do silano: G1 e G7 - 10s de condicionamento ácido, G2 e G8 - 20 s; G3 e G9 - 40 s; G4 e G10 - 60 s; G5 e G11 - 120 s e G6 e G12 - 60 + 60s. O silano foi aplicado em todos os grupos e metade dos grupos (de G7 a G12) receberam uma camada do adesivo (Scotchbond MP - 3M/ESPE). Molde de elastômero com dois orifícios cilíndricos (1,2mm de diâmetro x 2mm de altura) foi adaptado sobre a superfície da cerâmica para a construção de dois cilindros por amostra, totalizando 12 cilindros por grupo. Para tal, os orifícios foram preenchidos com o cimento resinoso (Variolink II), fotoativados por 40 s e submetidos ao ensaio de resistência de união ao microcisalhamento a velocidade de 0,5mm/min. e o padrão de fratura foi analisado. Os dados foram submetidos à Análise de Variância e ao teste de Student-Newman-Keul (p<0,05). A topografia e a interface de união foram avaliadas em MEV. A resistência de união ao microcisalhamento (MPa) foi 19,4±3,5 (G1), 22,3±5,1 (G2), 22,2±3,2 (G3), 17,8±2,1 (G4), 15,3±3,0 (G5), 14,3±1,8 (G6) para os grupos tratados com silano, e 17,4±4,8 (G7), 21,3±2,1 (G8), 21,1±2,3 (G9), 24,7±5,8 (G10), 20,4±2,2 (G11) e 18,5±4,6 (G12) para os grupos tratados com silano + adesivo. Houve redução de falhas adesivas e aumento das mistas com o aumento do tempo de condicionamento para os grupos tratados com silano e equilíbrio da falhas adesivas e mistas para os grupos tratados com silano + adesivo, exceto para os grupos G11 e G12 onde houve predominância de falhas mistas. Pouca alteração na topografia de superfície foi detectada nas amostras condicionadas por 10s, canais apresentando sulcos profundos puderam ser notados em praticamente toda a extensão das superfícies cerâmicas recondicionadas (60+60s - G6 e G12). Espaços não-preenchidos ao longo da interface cerâmica-cimento resinoso foram detectados em intensidade crescente a partir de 60s de condicionamento, quando apenas o silano foi aplicado, enquanto um preenchimento homogêneo, caracterizado por íntimo contato com a cerâmica pode ser percebido quando o adesivo foi utilizado, exceto para o grupo recondicionado - G12. / Abstract: This study evaluated the influence of etching times on surface/interface morphology and micro-shear bond strength to Empress Esthetic leucite-reinforced glass ceramic (Ivoclar-Vivadent), with or without application of an unfilled resin after silane. Ceramic discs were divided into 12 groups (n = 6), defined by the etching time with 10% hydrofluoric acid: G1 and G7 - etching for 10s, G2 and G8 - 20 s; G3 and G9 - 40 s; G4 and G10 - 60 s; G5 and G11 - 120 s and G6 and G12 - 60 + 60s. Half of the groups (G7 to G12) received a layer of unfilled resin (Scotchbond MP/ 3M ESPE) after silane coupling. Micro-shear bonding test using Variolink II resin cement (Ivoclar-Vivadent) was performed, and data submitted to two-way ANOVA and Student-Newman-Keuls' test (p < 0.05). Evaluation of the etching pattern and bonding interfaces was conducted by Scanning Electron Microscopic (SEM). Means micro-shear bond strengths (MPa) were 19.4±3.5 (G1), 22.3±5.1 (G2), 22.2±3.2 (G3), 17.8±2.1 (G4), 15.3±3.0 (G5), 14.3±1.8 (G6) for groups treated with silane, and 17.4±4.8 (G7), 21.3±2.1 (G8), 21.1±2.3 (G9), 24.7±5.8 (G10), 20.4±2.2 (G11) e 18.5±4.6 (G12) for groups treated with silane and unfilled resin. Poor etching topography was detected on 10s etched surfaces, whereas fissures forming deep grooved channels were extensively observed in 120s and 60+60s ceramics surfaces. Unfilled spaces underlying the ceramic-resin cement interface were detected when only silane was applied. Fully completion of the irregularities on 60s and 120s samples were detected using the unfilled resin, although this material was unable to completely fill the irregularities on 60+60s (G12) ceramic. When only silane was applied, the 60s and the groups etched for longer periods (120 and 60+60s - G5 and G6) showed lower bond strengths, but when both silane and unfilled resin were applied, all etching times generally showed similar values. The etching protocol influenced the surface/interface topography and bond strength to ceramic. The application of unfilled resin was able to infiltrate all unfilled spaces beneath the ceramic-resin cement interface detected when only silane was applied, except on the re-etched (60+60s - G12) ceramic. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários

Page generated in 0.0939 seconds