Spelling suggestions: "subject:"composta""
31 |
Influencia das tecnicas de polimerização das resinas compostas na microinfiltração, microdureza, formação de fendas e resistencia a microtraçãoAmaral, Cristiane Mariote 03 August 2018 (has links)
Orientador : Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:08:29Z (GMT). No. of bitstreams: 1
Amaral_CristianeMariote_D.pdf: 5829891 bytes, checksum: 01f9016f921ae3f4d91df5d2fc859a91 (MD5)
Previous issue date: 2003 / Doutorado
|
32 |
Avaliação clínica de 2 anos de restaurações adesivas classe I = Two-year clinical evaluation of class I adhesive restorations / Two-year clinical evaluation of class I adhesive restorationsBertaglia, Priscila Camondy, 1981- 12 December 2014 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T11:37:31Z (GMT). No. of bitstreams: 1
Bertaglia_PriscilaCamondy_D.pdf: 1620456 bytes, checksum: 044aa4cbf344b86191934f41f4525929 (MD5)
Previous issue date: 2015 / Resumo: O objetivo deste estudo in vivo foi avaliar clinicamente através do critério USPHS e a sensibilidade pós-operatória de restaurações Classe I de compósito nanoparticulado, associado a sistemas de união do tipo condicionamento total e autocondicionante. Trinta e duas restaurações de amálgama Classe I foram substituídas por restaurações adesivas. Após a confecção do preparo cavitário, as restaurações foram confeccionadas aleatoriamente, sob isolamento absoluto, utilizando os seguintes grupos (n=8): G1 - Adper Single Bond 2 + Filtek Supreme XT (XT); G2 - Adper Easy One Bond + XT; G3 - Adper Scotchbond + XT; G4 - Clearfil SE Bond + Filtek XT. A sensibilidade pós-operatória foi analisada através de escores antes da substituição (T1) (baseline), após 15 dias (T2), 12 meses (T3) e 24 meses (T4), utilizando-se estímulo frio e escala analógica de dor. A avaliação clínica das restaurações foram realizadas através de exame clínico direto em campo limpo e seco, utilizando o critério USPHS. O preenchimento da ficha de avaliação clínica (estabilidade de cor, integridade marginal, alteração de cor marginal, forma anatômica e cárie secundária) foram realizados nos tempos T2, T3 e T4, por um único avaliador. Ao final das avaliações, os dados foram agrupados e analisados estatisticamente. Ao compararmos a sensibilidade pós-operatória entre os grupos, não houve diferença estatística durante os tempos analisados e todos os grupos se comportaram de maneira semelhante quando avaliamos um único grupo durante os tempos analisamos, obtendo diferença estatística somente no T2, com relação aos demais. Com relação a avaliação clínica através do critério USPHS modificado, podemos observar que o grupo 2 apresentou a pior performance clínica com quantidades expressivas de restaurações com alteração de integridade marginal e de cor marginal, sendo 37,5% que necessitaram troca da restauração (escores Charlie). Os demais grupos se comportaram de maneira semelhante, mantendo-se em nível aceitável após 24 meses. Após a análise dos resultados, podemos concluir que o sistema adesivo autocondicionante de passo único apresentou menor longevidade das restaurações confeccionadas, se comparado aos demais sistemas utilizados, devendo ser utilizado com critério / Abstract: The aim of this in vivo study was to evaluate clinically through the USPHS criteria and postoperative sensitivity in Class I restorations restored with etch-and-rinse and self-etch adhesive system. Thirty-two Class I amalgam restorations are replaced with adhesive restorations. After the cavity preparation, the restorations were made randomly, under rubber dam, using the following groups (n = 8): G1 - 2 Single Bond + Filtek Supreme XT (XT); G2 - Adper Easy Bond + XT; G3 - Adper Scotchbond + XT; G4 - Clearfil SE Bond + XT. Postoperative sensitivity was analyzed using scores before (T1) (baseline), after 15 days (T2), 12 months (T3) and 24 months (T4), using cold stimulus and analog pain scale. The clinical evaluation of restorations were performed by USPHS criteria. The clinical evaluation (color stability, marginal integrity, marginal change color, anatomic form and secondary caries) were performed at the times T2 and T4, by a single evaluator. At the end of the assessment, data were grouped and analyzed statistically. No statistically significant difference when we compared the postoperative sensitivity between groups during the analyzed times and all groups behaved similarly when we evaluated a single group during the time, presenting statistical difference in T2 if we compared to others . The USPHS modified criteria indicated that G2 (EB+XT) had a worse clinical performance with significant amounts of exchanged restorations (37.5% requiring replacement - Charlie scores) with modification of marginal adaptation and marginal staining, . The other groups behaved similarly. The restorations were considered acceptable after 24 months. It is concluded that the one-step self-etching adhesive system showed a lower restoration longevity if compared to other systems used. The 2-step self-etch, 2-step and 3-step etch-and-rinse adhesive systems showed similar clinical results / Doutorado / Dentística / Doutora em Clínica Odontológica
|
33 |
Alternativas para a redução do stress de polimerização em restaurações de incremento únicoSilva, Marcelo Goulart Rodrigues da January 2018 (has links)
O objetivo desta tese foi avaliar alternativas para a redução do stress de polimerização em restaurações de incremento único, através da adição de tiouretanos em resinas compostas e do uso de resinas compostas aquecidas. Para tanto, este trabalho foi dividido em três diferentes artigos com objetivos específicos, sendo eles: (1) testar o efeito da silanização de cargas inorgânicas com um novo silano contendo tiouretano em diferentes concentrações; (2) comparar o efeito da adição de tiouretano na matriz orgânica, carga silanizada ou associado à carga e matriz de resinas compostas ,experimentais; (3) testar o efeito de diferentes técnicas de incremento único utilizando resina composta préaquecida e uma resina experimental com adição de tiouretano no stress de polimerização, temperatura intrapulpar e grau de conversão. No primeiro artigo, dois diferentes tiouretanos foram sintetizados e uma carga inorgânica de vidro foi silanizada com dife rentes concentrações destes tiouretanos. O uso destas cargas em resinas compostas experimentais causou um aumento no grau de conversão e na tenacidade à fratura associado com uma redução no stress de polimerização. No segundo artigo um tiouretano foi sintetizado e adicionado em resinas compostas experimentais: 1) somente na matriz orgânica; 2) através de uma carga silanizada; ou 3) na matriz e na carga. Além disto, diferentes matrizes orgânicas foram testadas. A adição de tiouretano aumentou significativamente a tenacidade à fratura e reduziu o stress de polimerização das resinas experimentais. A associação de tiouretano na matriz e na carga potencializou a redução do stress de polimerização observado. No terceiro artigo cavidades classe I com 4mm de profundidade foram restauradas em incremento único com uma resina composta em temperatura ambiente ou aquecida, ou com uma resina experimental modificada através da adição de tiouretano na matriz e na carga, ou uma resina composta tipo "bulk-fill" de consistência regular. O préaquecimento não resultou em uma redução do stress de polimerização. Por outro lado, o material experimental contendo tiouretano apresentou uma redução significante do stress de polimerização juntamente com um aumento do grau de conversão. A incorporação de tiouretanos em novos materiais de incremento único é capaz de gerar materiais com melhores propriedades e reduzido stress de polimerização. Entretanto, o pré-aquecimento de resinas compostas não Parece uma alternativa clinicamente viável para a redução do stress de polimerização ou aumento do grau de conversão.
|
34 |
Análise clínica comparativa das condições do periodonto em resposta a procedimentos restauradores com invasão do espaço biologicoCayana, Ezymar Gomes January 2005 (has links)
O presente ensaio clínico comparou clinicamente, a resposta periodontal em humanos a procedimentos restauradores com invasão do espaço biológico do periodonto, restaurados transcirurgicamente ou após aumento de coroa clínica em 10 pacientes com idade entre 19 e 35 anos. Os exames inicial, 45, 90 e 180 dias, foram realizados por um examinador calibrado, que avaliou Índice de Placa Visível (IPV) e de Sangramento Gengival (ISG), Profundidade de Sondagem (PS), Perda de Inserção Clínica (PIC). Também foi registrada, a medida da distância da parede cervical da restauração até a crista óssea; após a conclusão das restaurações e ao final de 6 meses. Foram utilizadas resinas compostas tipo Filtek Flow ® (3M-ESPE) e Charisma ® (Hareuas-Kulser). Generalized Estimating Equations, Teste de Wald e Teste t foram utilizados para análise estatística (p ≤ 0,05). IPV e ISG mantiveram-se abaixo dos 10% ao final do estudo. Aos 180 dias a PS retornou a valores semelhantes do nível inicial para ambos os grupos, de 2,5 mm para 2,4 mm nos sítios tratados. Os sítios tratados com restauração transcirúrgica, a perda de inserção clínica manteve-se estável ao longo do estudo, de 0,8 mm no ínicio para 0,6 mm ao final; Enquanto que nos locais onde foi realizado aumento de coroa clínica a perda de inserção clínica foi significativa, de 0,6 mm para 2,2 mm nos sítios tratados, de 0,5 mm para 1,7 mm nos sítios contíguos e de 0,7 mm para 1,1 mm nos sítios opostos. Com relação à margem gengival, a posição da parede cervical da restauração após 180 dias, ficou mais freqüentemente localizada subgengivalmente para os locais onde foram realizadas restaurações transcirúrgicas. A distância da parede cervical da restauração à crista óssea se manteve inalteralda nos locais onde foram realizadas restaurações transcirúrgicas, enquanto que nos locais onde foram feitos aumentos de coroa clínica, a distância diminuiu de 3,0 mm para 2,2 mm, sendo esta diferença significativa. A resposta periodontal associada a restaurações adesivas realizadas transcirurgicamente com invasão do espaço biológico do periodonto foi semelhante aquela observada em locais onde as restaurações foram realizadas após procedimentos de aumento de coroa clínica e respeitando o espaço biológico do periodonto.
|
35 |
Análise clínica comparativa das condições do periodonto em resposta a procedimentos restauradores com invasão do espaço biologicoCayana, Ezymar Gomes January 2005 (has links)
O presente ensaio clínico comparou clinicamente, a resposta periodontal em humanos a procedimentos restauradores com invasão do espaço biológico do periodonto, restaurados transcirurgicamente ou após aumento de coroa clínica em 10 pacientes com idade entre 19 e 35 anos. Os exames inicial, 45, 90 e 180 dias, foram realizados por um examinador calibrado, que avaliou Índice de Placa Visível (IPV) e de Sangramento Gengival (ISG), Profundidade de Sondagem (PS), Perda de Inserção Clínica (PIC). Também foi registrada, a medida da distância da parede cervical da restauração até a crista óssea; após a conclusão das restaurações e ao final de 6 meses. Foram utilizadas resinas compostas tipo Filtek Flow ® (3M-ESPE) e Charisma ® (Hareuas-Kulser). Generalized Estimating Equations, Teste de Wald e Teste t foram utilizados para análise estatística (p ≤ 0,05). IPV e ISG mantiveram-se abaixo dos 10% ao final do estudo. Aos 180 dias a PS retornou a valores semelhantes do nível inicial para ambos os grupos, de 2,5 mm para 2,4 mm nos sítios tratados. Os sítios tratados com restauração transcirúrgica, a perda de inserção clínica manteve-se estável ao longo do estudo, de 0,8 mm no ínicio para 0,6 mm ao final; Enquanto que nos locais onde foi realizado aumento de coroa clínica a perda de inserção clínica foi significativa, de 0,6 mm para 2,2 mm nos sítios tratados, de 0,5 mm para 1,7 mm nos sítios contíguos e de 0,7 mm para 1,1 mm nos sítios opostos. Com relação à margem gengival, a posição da parede cervical da restauração após 180 dias, ficou mais freqüentemente localizada subgengivalmente para os locais onde foram realizadas restaurações transcirúrgicas. A distância da parede cervical da restauração à crista óssea se manteve inalteralda nos locais onde foram realizadas restaurações transcirúrgicas, enquanto que nos locais onde foram feitos aumentos de coroa clínica, a distância diminuiu de 3,0 mm para 2,2 mm, sendo esta diferença significativa. A resposta periodontal associada a restaurações adesivas realizadas transcirurgicamente com invasão do espaço biológico do periodonto foi semelhante aquela observada em locais onde as restaurações foram realizadas após procedimentos de aumento de coroa clínica e respeitando o espaço biológico do periodonto.
|
36 |
Análise clínica comparativa das condições do periodonto em resposta a procedimentos restauradores com invasão do espaço biologicoCayana, Ezymar Gomes January 2005 (has links)
O presente ensaio clínico comparou clinicamente, a resposta periodontal em humanos a procedimentos restauradores com invasão do espaço biológico do periodonto, restaurados transcirurgicamente ou após aumento de coroa clínica em 10 pacientes com idade entre 19 e 35 anos. Os exames inicial, 45, 90 e 180 dias, foram realizados por um examinador calibrado, que avaliou Índice de Placa Visível (IPV) e de Sangramento Gengival (ISG), Profundidade de Sondagem (PS), Perda de Inserção Clínica (PIC). Também foi registrada, a medida da distância da parede cervical da restauração até a crista óssea; após a conclusão das restaurações e ao final de 6 meses. Foram utilizadas resinas compostas tipo Filtek Flow ® (3M-ESPE) e Charisma ® (Hareuas-Kulser). Generalized Estimating Equations, Teste de Wald e Teste t foram utilizados para análise estatística (p ≤ 0,05). IPV e ISG mantiveram-se abaixo dos 10% ao final do estudo. Aos 180 dias a PS retornou a valores semelhantes do nível inicial para ambos os grupos, de 2,5 mm para 2,4 mm nos sítios tratados. Os sítios tratados com restauração transcirúrgica, a perda de inserção clínica manteve-se estável ao longo do estudo, de 0,8 mm no ínicio para 0,6 mm ao final; Enquanto que nos locais onde foi realizado aumento de coroa clínica a perda de inserção clínica foi significativa, de 0,6 mm para 2,2 mm nos sítios tratados, de 0,5 mm para 1,7 mm nos sítios contíguos e de 0,7 mm para 1,1 mm nos sítios opostos. Com relação à margem gengival, a posição da parede cervical da restauração após 180 dias, ficou mais freqüentemente localizada subgengivalmente para os locais onde foram realizadas restaurações transcirúrgicas. A distância da parede cervical da restauração à crista óssea se manteve inalteralda nos locais onde foram realizadas restaurações transcirúrgicas, enquanto que nos locais onde foram feitos aumentos de coroa clínica, a distância diminuiu de 3,0 mm para 2,2 mm, sendo esta diferença significativa. A resposta periodontal associada a restaurações adesivas realizadas transcirurgicamente com invasão do espaço biológico do periodonto foi semelhante aquela observada em locais onde as restaurações foram realizadas após procedimentos de aumento de coroa clínica e respeitando o espaço biológico do periodonto.
|
37 |
Avaliação Clínica de Restaurações de Classe III com Resinas Compostas.Sá, Fatima Cristina de 16 March 2000 (has links)
Avaliou-se clinicamente 2 resinas compostas (Z-100 e Fill Magic),quanto a: sensibilidade pós-operatória, forma anatômica, cárie secundária, integridade marginal, descoloração marginal, cor e a influência do período de observação (baseline", 6 meses, 1 ano e 2 anos) no desempenho desses fatores. Participaram 43 pacientes, que receberam 2 restaurações de classe III, 1 de cada resina, totalizando 86 restaurações. Fez-se a avaliação inicial das restaurações, o baseline", 7 dias após a sua confecção, por 2 examinadores. Cada item recebia um escore em 3 níveis: bom (0), aceitável (1) e inaceitável (2). Somente para a cárie considerava-se 2 níveis: ausente (0) e presente (1). Fotografou-se as restaurações em todos os períodos de observação. Obteve-se moldagens das restaurações de 10 pacientes, para análise e fotografias em Microscópio Eletrônico de Varredura, com aumento de 40 X. Dos 43 pacientes, 8 não retornaram, assim, analisou-se estatisticamente pelo teste exato de Fisher, 70 restaurações. No baseline, 34 restaurações com a resina composta Z-100 e 35 com a Fill Magic receberam escores zero em todas as categorias, com exceção de 1 caso com a resina Z-100 que recebeu escore 1 para o critério cor. Para esse mesmo critério, aos 6 meses, 35 restaurações com a Fill Magic e com a Z-100, 31 restaurações receberam escores zero e 4 mereceram escores 1. Em 1 ano, 31 restaurações com a Z-100 ficaram com escores zero e 4 com escores 1; 34 restaurações com Fill Magic obtiveram escores zero e 1 obteve escore 1, com relação à cor. Aos 2 anos, também com relação à cor, para 3 restaurações com Z-100 e para 1 com Fill Magic atribuíram-se escores 1; escores 0 foram aplicados a 32 das restaurações de Z-100 e a 34 das de Fill Magic. Exceto para a categoria cor, que sofreu mudanças com o passar do tempo, todas as restaurações receberam escores 0 na avaliação baseline", 6 meses, 1 ano e 2 anos. Nenhum escore 2 foi anotado. Não observou-se diferença estatisticamente significante entre as 2 resinas compostas, aceitando-se a hipótese de igualdade entre as mesmas. / The purpose of this study was to clinically evaluate two composite resins at 2-year period. Seventy Class III restorations were made by only one operator, 35 with Z-100 composite resin and 35 with Fill Magic. The teeth were selected based on clinical exams. Restorations included only anterior superior teeth. Following cavity preparations, under rubber dam, they were protected with calcium hydroxide and/or a glass ionomer base. Magic Adhesiv/Fill Magic (Vigodent) and Scotchbond Multipurpose Plus/Z-100 (3M) were used for adhesion to exposed dentin and enamel and restoration of the cavities. The cavities were restored in increments. Restorations were finished using multi-laminated burs, Sof-Lex discs and Enhance System. Evaluation was assessed after finishing and polishing approximately one week after placement (baseline), 6 months, 1 year and 2 years using the modified Ryge criteria for color, marginal discoloration, anatomic form, marginal integrity, secondary caries and post-operative sensitivity. There were three levels of scores for each category: good (0), acceptable (1) and unacceptable (2). Only for secondary caries there were 2 levels: absent (0) and present (1). Besides, it was investigated the occurrence of postoperative sensitivity, which was classified as the other scores were for another characteristics observed. At every evaluation, impressions from the restorations were made and they were examined by scanning electron microscopy. At baseline, there was one score one" for category color for Z-100 composite resin; the other restorations and the other composite resin were graded to be zero". At 6 months recall, the restorations were assessed and there were four scores one" for Z-100 composite resin. The restorations were evaluated at 1 year and the results were as follow: there were four scores one" for Z-100 composite resin and one score one" for Fill Magic composite resin with regard to color. At 2-year evaluation were observed three scores one" for Z-100 composite resin and one score one" for Fill Magic. Except for color category, all the restorations received score zero" either for 6 months, 1-year and 2- year recalls. No scores two" were noted. The results were analyzed by Fisher Exact Statistical Test. No significant differences were noted between both composite resins. In conclusion, these two composite resins demonstrated excellent clinical acceptability in all categories assessed, making them suitable for anterior restorations.
|
38 |
"Avaliação da resistência a tração de reparos em resina composta". / Traction strength assessment of repairs in composite resinMurad, Cintia Gaio 13 February 2003 (has links)
Este trabalho foi desenvolvido com o objetivo de avaliar in vitro a resistência adesiva em reparos de resina composta utilizando um sistema adesivo, com uso prévio ou não de silanizadores na área de emenda, em corpos de prova submetidos a testes de tração. Esses foram preparados em um dispositivo de aço inoxidável que fornecia corpos de prova em forma de halteres. Oitenta metades de corpos de prova foram confeccionados com resina composta microhíbrida Esthet-X (Dentsply Indústria e Comércio Ltda.), obtendo-se assim, os hemi-halteres. Após permanecerem armazenados em água destilada durante quinze dias, os meio espécimes tiveram a interface do reparo desgastada com uma ponta diamantada, em seguida, condicionada por trinta segundos com ácido fosfórico 37%, lavada com água por vinte segundos, e seca com ar comprimido. Os hemi-halteres foram divididos em quatro grupos de vinte espécimes, em que cada grupo recebeu um sistema adesivo: Grupo I: uma camada de adesivo Prime&Bond 2.1 (Dentsply Indústria e Comércio Ltda.); Grupo II: uma camada de silano (Silano Dentsply Indústria e Comércio Ltda.) mais uma camada de adesivo; Grupo III: uma camada de silano; Grupo IV: três camadas de silano. Os espécimes foram recolocados no dispositivo metálico, e o reparo foi completado com a inserção da mesma resina composta. Estes foram mantidos em água destilada novamente, por 24 horas, e submetidos a teste de tração na máquina de ensaio universal EMIC, com velocidade de carregamento de 0,5mm/min. Os testes estatísticos aplicados foram Análise de Variância a um critério ANOVA seguido de Teste de Tukey (p<5%). Os resultados obtidos foram (média ± desvio padrão) para o Grupo I: 28,93 ±7,68; Grupo II: 27,87±9,57; Grupo III: 20,59±5,82 e Grupo IV: 22,0±6,69, demonstrando que a aplicação de adesivo tem influência positiva, estatisticamente significante na resistência à tração, comparado com a aplicação isolada do silano. A associação adesivo/silano não demonstrou vantagem em relação ao uso isolado do agente adesivo, e o uso de três camadas de silano não elevou a resistência adesiva comparada com a aplicação da camada única. / The aim of this study was to evaluate in vitro the tensile bonding strength of repairs in composite resin using an adhesive system, with or without the previous use of silane on the junction of test bodies submitted to traction tests. The test bodies were prepared in a stainless steel device that provides the shape of a dumb-bell. Eighty half-test bodies were manufactured with microhybrid composite resin Esthet-X (Dentsply) in the shape of half dumb-bells. After being stored in distilled water for fifteen days, the repair surfaces were abraded with a diamond bur, conditioned in phosphoric acid at 37% for 30 seconds, rinsed with water and air-dried. After that, the half test bodies were divided into four groups of twenty units, and each group received one type of adhesive system: Group I: one layer of adhesive system Prime&Bond 2.1 (Dentsply); Group II: one layer of silane (Silano Dentsply) plus one layer of adhesive system; Group III: one layer of silane and Group IV: three layers of silane. The specimens were put back into the metallic device and the repair was carried out with the same composite resin. They were again kept in distilled water for 24 hours and submitted to a traction test in an EMIC universal testing machine, with a loading speed of 0.5 mm/min. The data was analyzed by ANOVA and Tukeys test (p<5%). The results obtained were (mean ± standard deviation) for Group I: 28,93±7,68; Group II: 27,87±9,57; Group III: 20,59±5,82 and Group IV: 22,0±6,69, showing that the use of an adhesive system has positive, statistically significant, influence on the restoration tensile bonding strength, compared with using silane alone. The association adhesive/silane didnt show advantage compared with the use of the adhesive system alone, and the use of three layers of silane didnt improve the bonding strength on the use of just one layer.
|
39 |
'Creep' em resinas compostas fotopolimerizáveis. / Creep of light-cured posterior composite resinsCouto, Marcelo Guerino Pereira 25 April 2000 (has links)
As resinas compostas vêm sofrendo inúmeras alterações com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles sua resistência ao desgaste e à abrasão, a contração de polimerização, a microinfiltrção marginal, e sua deformação permanente (importante propriedade em situações clínicas onde existem áreas sujeitas às forças oclusais) e esta, normalmente não é considerada. Visando determinar o creep", por meio da deformação permanente, amostras confeccionadas com resinas compostas fotopolimerizáveis: ALERT [A] (Jeneric®/Pentron®), CHARISMA F [C] (Heraeus/Kulzer), HELIOMOLAR RADIOPAQUE [H] (Vivadent), SOLITAIRE [S] (Heraeus/Kulzer) e TETRIC CERAM [T] (Vivadent) após armazenamento em água, à temperatura de 37 + 1ºC, foram submetidas a uma carga compressiva constante de 36MPa, por períodos de: 15 minutos, 1 hora e 24 horas. Os resultados obtidos apresentam os valores quantitativos da diferença entre o comprimento original da amostra e o seu comprimento após o ensaio, em cada período estabelecido. A análise estatística dos dados apresentados pelas cinco resinas compostas avaliadas nos quatro períodos determinados, demonstrou resultados de creep estático" (em ordem decrescente), para o período de 15 minutos: [H] (X=1,0192%), [T] (X=0,8787%), [C] (X=0,7469%), [S] (X=0,6738%) e [A] (X = 0,5095%). Para o período de 1 hora: [H] (X=1,5546%), [T] (X=1,2082%), [C] (X=0,9744%), [S] (X=0,8245%), [A] (X=0,6348%) e, para o último período observado, 24 horas, obteve-se a seguinte seqüência: [H] (X=2,3747%), [T] (X=1,7993%), [C] (X=1,2812%), [S] (X=1,2645%) e [A] (X=0,7600). Os valores médios do creep estático" das resinas CHARISMA F e SOLITAIRE não foram estatisticamente diferentes em qualquer um dos períodos estudados, sendo que no período de 15 minutos, os resultados obtidos para a resina TETRIC CERAM também se assemelharam aos destas e, em 1 hora, os da resina composta ALERT foram similares aos das duas primeiras; porém, a resina HELIOMOLAR RADIOPAQUE, apresentou mensurações divergentes das anteriores, demonstrando piores características de deformação permanente, por possuir maiores valores de creep estático" em qualquer período estudado. / The posterior composite resins dental restorative materials, have been, extensively, used in substitution of dental amalgam, in function of its aesthetic best. Although the use of those resins, in areas subject to the forces occlusal, increased significantly, the nead evaluation of the behavior of static creep"important property to be considered in those situationsit is not very disclosed. For this reason, the objective of the present paper was to determine the static creep" of the composite resins: Alert [A], Charisma F [C], Heliomolar Radiopaque [H], Solitaire [S] and Tetric Ceram [T], by evaluation means of the permanent deformation. That deformation was determined in specimens submitted to a constant compressive load of 36MPa, in 37 + 1ºC, immerged in recipient contend water, for periods of 15 minutes, 1 hour and 24 hours. The results obtained in that experiment present the quantitative values of the creep" in crescent order, for the period of 15 minutes: H, T, C, S, A; in 1 hour: H, T, C, S, A and in 24 hours: H, T, C, S, A. The profile analysis of the creep" for five composite resins evaluated in the four pre-determined periods demonstrated similar results for C, S, T in 15 minutes, A, C, S, in 1 hour and C, S for 24 hour, and different for H in every observed time.
|
40 |
Comparação de dois sistemas de fotoativação de resinas compostas, LED e lâmpada halógena: avaliação através de dureza em amostras de resina compostaPires, Humberto Carlos 22 March 2005 (has links)
O presente estudo objetivou avaliar a eficiência de dois sistemas de fotoativação de resinas compostas, diodos emissores de luz (LED) e à base de lâmpada halógena, e verificar se existe correlação entre a eficácia desses sistemas e a intensidade de luz (mW/cm2) produzida pelos mesmos. O método utilizado foi o teste de dureza em amostras de um compósito híbrido fotoativável (Z100, 3M/ESPE, cor A3). Foram selecionados 26 aparelhos fotoativadores, sendo 18 à base de LED e 8 à base de lâmpada halógena. Para aferir a intensidade de luz emitida pelos aparelhos, foi utilizado um radiômetro (Demetron, modelo 100). Cada espécime (n=5/aparelho) foi confeccionado com o auxílio de uma matriz metálica, constituída por duas partes chamadas de hemimatrizes inferior e superior, cada uma com 2mm de espessura e orifício central com diâmetro de 5mm. Sobre a hemimatriz inferior preenchida com resina, era colocado um pedaço de tira de poliéster, sobre o qual, com uma lâmina de vidro, era exercida uma pressão para promover uma superfície lisa e plana. Posicionava-se então a hemimatriz superior e, após seu preenchimento, colocava-se um outro pedaço de tira de poliéster, e nova pressão era exercida com a lâmina de vidro. A fotoativação era efetuada durante 40s com a ponta ativa de uma das unidades fotoativadoras mantida em contato com a tira de poliéster, colocada sobre a hemimatriz superior. Assim, cada espécime era composto de duas partes, uma superior e outra inferior, cada uma com 2mm de espessura. Dez minutos após a fotoativação, as hemimatrizes inferior e superior eram separadas e realizavam-se 5 impressões de dureza Knoop (dureza inicial), com carga de 100g durante 10s, em cada uma das 4 superfícies, que eram: 1ª) metade superior do espécime, voltada para a fonte de luz (topo); 2ª) metade superior do espécime, oposta à fonte de luz (2mm-s, antes da tira de poliéster); 3ª) metade inferior do espécime, voltada para a fonte de luz (2mm-i, depois da tira de poliéster), e 4ª) metade inferior do espécime, oposta à fonte de luz (4mm de profundidade ou base). Após 7 dias de estocagem numa estufa a 37ºC, novas leituras de dureza eram realizadas (dureza final). Verificou-se que: 1) houve aumento da dureza da medição imediata para a com 7 dias; 2) os valores de dureza decresceram com o aumento da profundidade; 3) o uso de um radiômetro é importante para aferir os aparelhos fotoativadores, visto que todos emitiram intensidades de luz menores que a informada pelos fabricantes; 4) a melhor profundidade para avaliação da eficiência de aparelhos fotoativadores é a de 2mm, que é a espessura indicada para que ocorra uma polimerização adequada; 5) dentre os 26 aparelhos pesquisados pode-se identificar 5 grupos distintos, assim divididos a partir do de melhores resultados: I) LED com intensidade de luz de 350 a 800mW/cm2; II) LED de 250 a 330mW/cm2 e Hal. de 340 a 500mW/cm2; III) LED de 170 a 210mW/cm2 e Hal. de 220mW/cm2; IV) LED de 120 a 140mW/cm2; e V) Hal. de 60mW/cm2. Esses resultados permitem concluir que: 1) a eficiência das unidades fotoativadoras, tanto para os sistemas à base de lâmpada halógena como à base de LED, está principalmente relacionada com a intensidade de luz, visto que os aparelhos que apresentaram melhor desempenho foram os de maior potência, independentemente da fonte utilizada; 2) é de fundamental importância que os fabricantes de aparelhos fotoativadores informem o comprimento de onda emitido, e que os dentistas clínicos e pesquisadores certifiquem e monitorem a intensidade de luz emitida por esses aparelhos. Da mesma forma, os fabricantes de resina composta e de outros materiais poliméricos fotossensíveis deveriam informar tanto a energia necessária para que ocorra uma eficiente polimerização, como o tipo de substância fotossensível utilizada na composição de seus materiais. / The purpose of this study was to evaluate the efficiency of two light curing systems (Light Emitting Diodes LED and Halogen) on composite resins, and also to check whether there is a relationship between the effectiveness of these systems and the light intensity produced by them. Hardness tests were performed in specimens made of a light cured composite resin (Z100, 3M/ESPE A3). Twenty six curing units were selected, being 18 LEDs and 8 halogen units. A curing radiometer (Demetron, model 100) was used to measure the light intensity produced by the units. Each specimen (n=5/unit) was produced into a metallic split mold made of two parts, each of them 2mm deep with a 5-mm diameter central hole. A polyester strip and then a glass slab were placed on top of the bottom part of the split mold filled with resin and some pressure was made in order to keep the surface smooth and plain. The top of the mold was then put back, and after filling with the resin, the same process was done with a new application of pressure on the glass. The sample was cured for 40s with the tip of one of the curing units in contact with the polyester strip, on the top part of the split mold. As already mentioned, each specimen was made of two parts, one top and one bottom, 2mm deep each. Ten minutes after curing, the parts of the split mold were separated and 5 Knoop hardness tests (initial hardness) were performed, with 100g pressure for 10s on each of the 4 surfaces, as follows: 1) top half of the specimen directed to the light source (top); 2) top half of the specimen opposite to the light source (2mm-s, before polyester strip); 3) bottom half of the specimen directed to the light source (2mm-i, after the polyester strip); and 4) bottom half of the specimen opposite to the light source (4mm deep or bottom). After a 7-day storage at 37ºC, new hardness tests were performed (final hardness). The following was observed: 1) There was an increase in final hardness compared to the initial; 2) The hardness values decreased with the increase of depth; 3) Utilization of the curing radiometer is important to check the light curing units, since all produced lower light intensity than informed by the manufacturers; 4) the best depth for evaluation of the efficiency of light curing units is 2mm, which is the thickness indicated to allow proper curing; 5) Among the 26 units used, five groups could be distinctively identified according to the best results as follows: I) LED units with light intensity from 350 to 800 mW/cm2; II) LED units with light intensity from 250 to 330 mW/cm2 and halogen units from 340 to 500 mW/cm2; III) LED units with light intensity at 210 mW/cm2 and halogen at 220 mW/cm2; IV) LED units with light intensity from 120 to 140 mW/cm2; and V) halogen unit with light intensity at 60 mW/cm2. These results reveal that: 1) the efficiency of curing units, either LED or halogen units, is primarily related to the light intensity, since the units with the best performances were those with the highest outputs, regardless of the light source; 2) it is fundamental that manufacturers of light curing units inform the wavelength emitted, and dental practitioner and investigators should check and control the light intensity emitted by these units. Similarly, the manufacturers of composite resins and other light cured polymer materials should inform both the energy required for efficient curing and the type of light curing substance added in the composition of materials.
|
Page generated in 0.055 seconds