• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 100
  • 40
  • 24
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 61
  • 52
  • 39
  • 31
  • 31
  • 28
  • 24
  • 23
  • 22
  • 19
  • 17
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Treatment verification in proton therapy based on the detection of prompt gamma-rays

Golnik, Christian 22 July 2016 (has links)
Background The finite range of a proton beam in tissue and the corresponding steep distal dose gradient near the end of the particle track open new vistas for the delivery of a highly target-conformal dose distribution in radiation therapy. Compared to a classical photon treatment, the potential therapeutic benefit of a particle treatment is a significant dose reduction in the tumor-surrounding tissue at a comparable dose level applied to the tumor. Motivation The actually applied particle range, and therefor the dose deposition in the target volume, is quite sensitive to the tissue composition in the path of the protons. Particle treatments are planned via computed tomography images, acquired prior to the treatment. The conversion from photon stopping power to proton stopping power induces an important source of range-uncertainty. Furthermore, anatomical deviations from planning situation affect the accurate dose deposition. Since there is no clinical routine measurement of the actually applied particle range, treatments are currently planned to be robust in favor of optimal regarding the dose delivery. Robust planning incorporates the application of safety margins around the tumor volume as well as the usage of (potentially) unfavorable field directions. These pretreatment safety procedures aim to secure dose conformality in the tumor volume, however at the price of additional dose to the surrounding tissue. As a result, the unverified particle range constraints the principle benefit of proton therapy. An on-line, in-vivo range-verification would therefore bring the potential of particle therapy much closer to the daily clinical routine. Materials and methods This work contributes to the field of in-vivo treatment verification by the methodical investigation of range assessment via the detection of prompt gamma-rays, a side product emitted due to proton-tissue interaction. In the first part, the concept of measuring the spatial prompt gamma-ray emission profile with a Compton camera is investigated with a prototype system consisting of a CdZnTe cross strip detector as scatter plane and three side-by-side arranged, segmented BGO block detectors as absorber planes. In the second part, the novel method of prompt gamma-ray timing (PGT) is introduced. This technique has been developed in the scope of this work and a patent has been applied for. The necessary physical considerations for PGT are outlined and the feasibility of the method is supported with first proof-of-principle experiments. Results Compton camera: Utilizing a 22-Na source, the feasibility of reconstructing the emission scene of a point source at 1.275 MeV was verified. Suitable filters on the scatter-absorber coincident timing and the respective sum energy were defined and applied to the data. The source position and corresponding source displacements could be verified in the reconstructed Compton images. In a next step, a Compton imaging test at 4.44 MeV photon energy was performed. A suitable test setup was identified at the Tandetron accelerator at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. This measurement setup provided a monoenergetic, point-like source of 4.44 MeV gamma-rays, that was nearly free of background. Here, the absolute gamma-ray yield was determined. The Compton imaging prototype was tested at the Tandetron regarding (i) the energy resolution, timing resolution, and spatial resolution of the individual detectors, (ii) the imaging capabilities of the prototype at 4.44 MeV gamma-ray energy and (iii) the Compton imaging efficiency. In a Compton imaging test, the source position and the corresponding source displacements were verified in the reconstructed Compton images. Furthermore, via the quantitative gamma-ray emission yield, the Compton imaging efficiency at 4.44 MeV photon energy was determined experimentally. PGT: The concept of PGT was developed and introduced to the scientific community in the scope of this thesis. A theoretical model for PGT was developed and outlined. Based on the theoretical considerations, a Monte Carlo (MC) algorithm, capable of simulating PGT distributions was implemented. At the KVI-CART proton beam line in Groningen, The Netherlands, time-resolved prompt gamma-ray spectra were recorded with a small scale, scintillator based detection system. The recorded data were analyzed in the scope of PGT and compared to the measured data, yielding in an excellent agreement and thus verifying the developed theoretical basis. For a hypothetical PGT imaging setup at a therapeutic proton beam it was shown, that the statistical error on the range determination could be reduced to 5 mm at a 90 % confidence level for a single spot of 5x10E8 protons. Conclusion Compton imaging and PGT were investigated as candidates for treatment verification, based on the detection of prompt gamma-rays. The feasibility of Compton imaging at photon energies of several MeV was proven, which supports the approach of imaging high energetic prompt $gamma$-rays. However, the applicability of a Compton camera under therapeutic conditions was found to be questionable, due to (i) the low device detection efficiency and the corresponding limited number of valid events, that can be recorded within a single treatment and utilized for image reconstruction, and (ii) the complexity of the detector setup and attached readout electronics, which make the development of a clinical prototype expensive and time consuming. PGT is based on a simple time-spectroscopic measurement approach. The collimation-less detection principle implies a high detection efficiency compared to the Compton camera. The promising results on the applicability under treatment conditions and the simplicity of the detector setup qualify PGT as method well suited for a fast translation towards a clinical trial.:1. Particle therapy 1.1 Introduction 1.2 The problem of particle range uncertainty 1.3 Currently investigated methods for treatment verification 1.4 Methods for prompt gamma-ray based treatment verification 1.4.1 Prompt gamma-ray imaging (PGI) 1.4.2 Prompt gamma-ray timing (PGT) 2. Physical relations 2.1 Interactions of protons with matter 2.1.1 Stopping of protons 2.1.2 Multiple Coulomb scattering (MCS) 2.1.3 Nonelastic collisions 2.2 Definition of deposited dose and proton range 2.2.1 Definition of dose D 2.2.2 The dose depth Dx , the proton fluence Φ, and the Bragg peak 2.2.3 The particle range 2.3 Production and delivery of proton beams 2.3.1 Acceleration of protons in a isochronous cyclotron 2.3.2 Beam delivery 2.4 Prompt gamma-ray emission 2.4.1 The production of prompt gamma-rays via nonelastic nuclear interactions 2.5 Interactions of photons with matter 2.5.1 Photoelectric absorption 2.5.2 Compton scattering 2.5.3 Pair production 2.5.4 Mass attenuation coefficient μ/ρ 2.6 Detection of photons 2.6.1 Semiconductor detectors 2.6.2 Scintillation detectors 3 Tests of a Compton camera for PGI 3.1 Principle of operation 3.2 Status of preceding work 3.3 Modifications to the existing Compton imaging prototype 3.4 Detectors of the prototype 3.4.1 The CZT scatter plane 3.4.2 The BGO absorber plane 3.4.3 The Compton imaging prototype 3.5 Electronic readout and event generation 3.6 Detector calibration 3.6.1 Calibration of the CZT detector 3.6.2 Calibration of a BGO detector 3.7 Compton imaging at 1.275 MeV photon energy 3.7.1 Imaging setup 3.7.2 Coincident timing 3.7.3 Coincident energy deposition 3.7.4 Image reconstruction 3.8 Compton imaging at 4.44 MeV photon energy 3.8.1 Beam setup at the Tandetron accelerator 3.8.2 Beam tuning at the Tandetron accelerator 3.8.3 The gamma-ray emission yield 3.8.4 Measurement setup 3.8.5 Energy detection 3.8.6 Spatial detection 3.8.7 Coincident timing 3.8.8 Coincident energy deposition 3.8.9 Detection efficiency η 3.8.10 Imaging setup 3.8.11 Image reconstruction 3.9 Implications for a therapeutic Compton imaging scenario 3.10 Summary and discussion 4 Prompt gamma-ray timing (PGT) 4.1 Theoretical description of PGT 4.1.1 Timing of prompt gamma-ray emission 4.1.2 Kinematics of protons 4.1.3 The correlation between spatial and temporal prompt gamma-ray emission in a thick target 4.1.4 Setup for time-resolved measurements of prompt gamma-rays 4.1.5 Uncertainty of the reference time 4.1.6 Standard error of the mean and confidence intervals of statistical momenta 4.1.7 A simplified MC method for the modeling of PGT 4.2 Experimental results 4.2.1 The GAGG detector 4.2.2 Detector energy resolution 4.2.3 Detector time resolution with 60-Co 4.2.4 Energy-resolved detector time resolution - the ELBE experiment 4.2.5 The KVI-CART proton beam line 4.2.6 Time-resolved measurement of prompt gamma-rays 4.2.7 Experimental determination of the system time resolution σ 4.2.8 PGT in dependence of proton transit time 4.3 Towards treatment verification with PGT 4.3.1 MC based PGT in dependence of proton range 4.3.2 MC based PGT at inhomogeneous targets 4.4 Implications for a therapeutic PGT scenario 4.4.1 Range verification for an exemplary PGT setup 4.4.2 Practical restrictions for the therapeutic PGT scenario 4.4.3 Principal limitations of the PGT method 4.5 Summary and outlook 5 Discussion Summary Zusammenfassung Bibliography Acknowledgement / Hintergrund Strahlentherapie ist eine wichtige Modalität der therapeutischen Behandlung von Krebs. Das Ziel dieser Behandlungsform ist die Applikation einer bestimmten Strahlendosis im Tumorvolumen, wobei umliegendes, gesundes Gewebe nach Möglichkeit geschont werden soll. Bei der Bestrahlung mit einem hochenergetischen Protonenstrahl erlaubt die wohldefinierte Reichweite der Teilchen im Gewebe, in Kombination mit dem steilen, distalen Dosisgradienten, eine hohe Tumor-Konformalität der deponierten Dosis. Verglichen mit der klassisch eingesetzten Behandlung mit Photonen ergibt sich für eine optimiert geplante Behandlung mit Protonen ein deutlich reduziertes Dosisnivau im den Tumor umgebenden Gewebe. Motivation Die tatsächlich applizierte Reichweite der Protonen im Körper, und somit auch die lokal deponierte Dosis, ist stark abhängig vom Bremsvermögen der Materie im Strahlengang der Protonen. Bestrahlungspläne werden mit Hilfe eines Computertomographen (CT) erstellt, wobei die CT Bilder vor der eigentlichen Behandlung aufgenommen werden. Ein CT misst allerdings lediglich den linearen Schwächungskoeffizienten für Photonen in der Einheit Hounsfield Units (HU). Die Ungenauigkeit in der Umrechnung von HU in Protonen-Bremsvermögen ist, unter anderem, eine wesentliche Ursache für die Unsicherheit über die tatsächliche Reichweite der Protonen im Körper des Patienten. Derzeit existiert keine routinemäßige Methode, um die applizierte Dosis oder auch die Protonenreichweite in-vivo und in Echtzeit zu bestimmen. Um das geplante Dosisniveau im Tumorvolumen trotz möglicher Reichweiteunterschiede zu gewährleisten, werden die Bestrahlungspläne für Protonen auf Robustheit optimiert, was zum Einen das geplante Dosisniveau im Tumorvolumen trotz auftretender Reichweiteveränderungen sicherstellen soll, zum Anderen aber auf Kosten der möglichen Dosiseinsparung im gesunden Gewebe geht. Zusammengefasst kann der Hauptvorteil einer Therapie mit Protonen wegen der Unsicherheit über die tatsächlich applizierte Reichweite nicht wirklich realisiert. Eine Methode zur Bestimmung der Reichweite in-vivo und in Echtzeit wäre daher von großem Nutzen, um das theoretische Potential der Protonentherapie auch in der praktisch ausschöpfen zu können. Material und Methoden In dieser Arbeit werden zwei Konzepte zur Messung prompter Gamma-Strahlung behandelt, welche potentiell zur Bestimmung der Reichweite der Protonen im Körper eingesetzt werden können. Prompte Gamma-Strahlung entsteht durch Proton-Atomkern-Kollision auf einer Zeitskala unterhalb von Picosekunden entlang des Strahlweges der Protonen im Gewebe. Aufgrund der prompten Emission ist diese Form der Sekundärstrahlung ein aussichtsreicher Kandidat für eine Bestrahlungs-Verifikation in Echtzeit. Zum Einen wird die Anwendbarkeit von Compton-Kameras anhand eines Prototyps untersucht. Dabei zielt die Messung auf die Rekonstruktion des örtlichen Emissionsprofils der prompten Gammas ab. Zum Zweiten wird eine, im Rahmen dieser Arbeit neu entwickelte Messmethode, das Prompt Gamma-Ray Timing (PGT), vorgestellt und international zum Patent angemeldet. Im Gegensatz zu bereits bekannten Ansätzen, verwendet PGT die endliche Flugzeit der Protonen durch das Gewebe und bestimmt zeitliche Emissionsprofile der prompten Gammas. Ergebnisse Compton Kamera: Die örtliche Emissionsverteilung einer punktförmigen 22-Na Quelle wurde wurde bei einer Photonenenergie von 1.275 MeV nachgewiesen. Dabei konnten sowohl die absolute Quellposition als auch laterale Verschiebungen der Quelle rekonstruiert werden. Da prompte Gamma-Strahlung Emissionsenergien von einigen MeV aufweist, wurde als nächster Schritt ein Bildrekonstruktionstest bei 4.44 MeV durchgeführt. Ein geeignetes Testsetup wurde am Tandetron Beschleuniger am Helmholtz-Zentrum Dresden-Rossendorf, Deutschland, identifiziert, wo eine monoenergetische, punktförmige Emissionverteilung von 4.44 MeV Photonen erzeugt werden konnte. Für die Detektoren des Prototyps wurden zum Einen die örtliche und zeitliche Auflösung sowie die Energieauflösungen untersucht. Zum Anderen wurde die Emissionsverteilung der erzeugten 4.44 MeV Quelle rekonstruiert und die zugehörige Effizienz des Prototyps experimentell bestimmt. PGT: Für das neu vorgeschlagene Messverfahren PGT wurden im Rahmen dieser Arbeit die theoretischen Grundlagen ausgearbeitet und dargestellt. Darauf basierend, wurde ein Monte Carlo (MC) Code entwickelt, welcher die Modellierung von PGT Spektren ermöglicht. Am Protonenstrahl des Kernfysisch Verschneller Institut (KVI), Groningen, Niederlande, wurden zeitaufgelöste Spektren prompter Gammastrahlung aufgenommen und analysiert. Durch einen Vergleich von experimentellen und modellierten Daten konnte die Gültigkeit der vorgelegten theoretischen Überlegungen quantitativ bestätigt werden. Anhand eines hypothetischen Bestrahlungsszenarios wurde gezeigt, dass der statistische Fehler in der Bestimmung der Reichweite mit einer Genauigkeit von 5 mm bei einem Konfidenzniveau von 90 % für einen einzelnen starken Spot 5x10E8 Protonen mit PGT erreichbar ist. Schlussfolgerungen Für den Compton Kamera Prototyp wurde gezeigt, dass eine Bildgebung für Gamma-Energien einiger MeV, wie sie bei prompter Gammastrahlung auftreten, möglich ist. Allerdings erlaubt die prinzipielle Abbildbarkeit noch keine Nutzbarkeit unter therapeutischen Strahlbedingungen nicht. Der wesentliche und in dieser Arbeit nachgewiesene Hinderungsgrund liegt in der niedrigen (gemessenen) Nachweiseffizienz, welche die Anzahl der validen Daten, die für die Bildrekonstruktion genutzt werden können, drastisch einschränkt. PGT basiert, im Gegensatz zur Compton Kamera, auf einem einfachen zeit-spektroskopischen Messaufbau. Die kollimatorfreie Messmethode erlaubt eine gute Nachweiseffizienz und kann somit den statistischen Fehler bei der Reichweitenbestimmung auf ein klinisch relevantes Niveau reduzieren. Die guten Ergebnissen und die ausgeführten Abschätzungen für therapeutische Bedingungen lassen erwarten, dass PGT als Grundlage für eine Bestrahlungsverifiktation in-vivo und in Echtzeit zügig klinisch umgesetzt werden kann.:1. Particle therapy 1.1 Introduction 1.2 The problem of particle range uncertainty 1.3 Currently investigated methods for treatment verification 1.4 Methods for prompt gamma-ray based treatment verification 1.4.1 Prompt gamma-ray imaging (PGI) 1.4.2 Prompt gamma-ray timing (PGT) 2. Physical relations 2.1 Interactions of protons with matter 2.1.1 Stopping of protons 2.1.2 Multiple Coulomb scattering (MCS) 2.1.3 Nonelastic collisions 2.2 Definition of deposited dose and proton range 2.2.1 Definition of dose D 2.2.2 The dose depth Dx , the proton fluence Φ, and the Bragg peak 2.2.3 The particle range 2.3 Production and delivery of proton beams 2.3.1 Acceleration of protons in a isochronous cyclotron 2.3.2 Beam delivery 2.4 Prompt gamma-ray emission 2.4.1 The production of prompt gamma-rays via nonelastic nuclear interactions 2.5 Interactions of photons with matter 2.5.1 Photoelectric absorption 2.5.2 Compton scattering 2.5.3 Pair production 2.5.4 Mass attenuation coefficient μ/ρ 2.6 Detection of photons 2.6.1 Semiconductor detectors 2.6.2 Scintillation detectors 3 Tests of a Compton camera for PGI 3.1 Principle of operation 3.2 Status of preceding work 3.3 Modifications to the existing Compton imaging prototype 3.4 Detectors of the prototype 3.4.1 The CZT scatter plane 3.4.2 The BGO absorber plane 3.4.3 The Compton imaging prototype 3.5 Electronic readout and event generation 3.6 Detector calibration 3.6.1 Calibration of the CZT detector 3.6.2 Calibration of a BGO detector 3.7 Compton imaging at 1.275 MeV photon energy 3.7.1 Imaging setup 3.7.2 Coincident timing 3.7.3 Coincident energy deposition 3.7.4 Image reconstruction 3.8 Compton imaging at 4.44 MeV photon energy 3.8.1 Beam setup at the Tandetron accelerator 3.8.2 Beam tuning at the Tandetron accelerator 3.8.3 The gamma-ray emission yield 3.8.4 Measurement setup 3.8.5 Energy detection 3.8.6 Spatial detection 3.8.7 Coincident timing 3.8.8 Coincident energy deposition 3.8.9 Detection efficiency η 3.8.10 Imaging setup 3.8.11 Image reconstruction 3.9 Implications for a therapeutic Compton imaging scenario 3.10 Summary and discussion 4 Prompt gamma-ray timing (PGT) 4.1 Theoretical description of PGT 4.1.1 Timing of prompt gamma-ray emission 4.1.2 Kinematics of protons 4.1.3 The correlation between spatial and temporal prompt gamma-ray emission in a thick target 4.1.4 Setup for time-resolved measurements of prompt gamma-rays 4.1.5 Uncertainty of the reference time 4.1.6 Standard error of the mean and confidence intervals of statistical momenta 4.1.7 A simplified MC method for the modeling of PGT 4.2 Experimental results 4.2.1 The GAGG detector 4.2.2 Detector energy resolution 4.2.3 Detector time resolution with 60-Co 4.2.4 Energy-resolved detector time resolution - the ELBE experiment 4.2.5 The KVI-CART proton beam line 4.2.6 Time-resolved measurement of prompt gamma-rays 4.2.7 Experimental determination of the system time resolution σ 4.2.8 PGT in dependence of proton transit time 4.3 Towards treatment verification with PGT 4.3.1 MC based PGT in dependence of proton range 4.3.2 MC based PGT at inhomogeneous targets 4.4 Implications for a therapeutic PGT scenario 4.4.1 Range verification for an exemplary PGT setup 4.4.2 Practical restrictions for the therapeutic PGT scenario 4.4.3 Principal limitations of the PGT method 4.5 Summary and outlook 5 Discussion Summary Zusammenfassung Bibliography Acknowledgement
182

Simulation studies for the in-vivo dose verification of particle therapy

Rohling, Heide January 2015 (has links)
An increasing number of cancer patients is treated with proton beams or other light ion beams which allow to deliver dose precisely to the tumor. However, the depth dose distribution of these particles, which enables this precision, is sensitive to deviations from the treatment plan, as e.g. anatomical changes. Thus, to assure the quality of the treatment, a non-invasive in-vivo dose verification is highly desired. This monitoring of particle therapy relies on the detection of secondary radiation which is produced by interactions between the beam particles and the nuclei of the patient’s tissue. Up to now, the only clinically applied method for in-vivo dosimetry is Positron Emission Tomography which makes use of the beta+-activity produced during the irradiation (PT-PET). Since from a PT-PET measurement the applied dose cannot be directly deduced, the simulated distribution of beta+-emitting nuclei is used as a basis for the analysis of the measured PT-PET data. Therefore, the reliable modeling of the production rates and the spatial distribution of the beta+-emitters is required. PT-PET applied during instead of after the treatment is referred to as in-beam PET. A challenge concerning in-beam PET is the design of the PET camera, because a standard full-ring scanner is not feasible. For instance, a double-head PET camera is applicable, but low count rates and the limited solid angle coverage can compromise the image quality. For this reason, a detector system which provides a time resolution allowing the incorporation of time-of-flight information (TOF) into the iterative reconstruction algorithm is desired to improve the quality of the reconstructed images. Secondly, Prompt Gamma Imaging (PGI), a technique based on the detection of prompt gamma-rays, is currently pursued. Concerning the emissions of prompt gamma-rays during particle irradiation, experimental data is not sufficiently available, making simulations necessary. Compton cameras are based on the detection of incoherently scattered photons and are investigated with respect to PGI. Monte Carlo simulations serve for the optimization of the camera design and the evaluation of criteria for the selection of measured events. Thus, for in-beam PET and PGI dedicated detection systems and, moreover, profound knowledge about the corresponding radiation fields are required. Using various simulation codes, this thesis contributes to the modelling of the beta+-emitters and photons produced during particle irradiation, as well as to the evaluation and optimization of hardware for both techniques. Concerning the modeling of the production of the relevant beta+-emitters, the abilities of the Monte Carlo simulation code PHITS and of the deterministic, one-dimensional code HIBRAC were assessed. The Monte Carlo tool GEANT4 was applied for an additional comparison. For irradiations with protons, helium, lithium, and carbon, the depth-dependent yields of the simulated beta+-emitters were compared to experimental data. In general, PHITS underestimated the yields of the considered beta+-emitters in contrast to GEANT4 which provided acceptable values. HIBRAC was substantially extended to enable the modeling of the depth-dependent yields of specific nuclides. For proton beams and carbon ion beams HIBRAC can compete with GEANT4 for this application. Since HIBRAC is fast, compact, and easy to modify, it could be a basis for the simulations of the beta+-emitters in clinical application. PHITS was also applied to the modeling of prompt gamma-rays during proton irradiation following an experimental setup. From this study, it can be concluded that PHITS could be an alternative to GEANT4 in this context. Another aim was the optimization of Compton camera prototypes. GEANT4 simulations were carried out with the focus on detection probabilities and the rate of valid events. Based on the results, the feasibility of a Compton camera setup consisting of a CZT detector and an LSO or BGO detector was confirmed. Several recommendations concerning the design and arrangement of the Compton camera prototype were derived. Furthermore, several promising event selection strategies were evaluated. The GEANT4 simulations were validated by comparing simulated to measured energy depositions in the detector layers. This comparison also led to the reconsideration of the efficiency of the prototype. A further study evaluated if electron-positron pairs resulting from pair productions could be detected with the existing prototype in addition to Compton events. Regarding the efficiency and the achievable angular resolution, the successful application of the considered prototype as pair production camera to the monitoring of particle therapy is questionable. Finally, the application of a PET camera consisting of Resistive Plate Chambers (RPCs) providing a good time resolution to in-beam PET was discussed. A scintillator-based PET camera based on a commercially available scanner was used as reference. This evaluation included simulations of the detector response, the image reconstructions using various procedures, and the analysis of image quality. Realistic activity distributions based on real treatment plans for carbon ion therapy were used. The low efficiency of the RPC-based PET camera led to images of poor quality. Neither visually nor with the semi-automatic tool YaPET a reliable detectability of range deviations was possible. The incorporation of TOF into the iterative reconstruction algorithm was especially advantageous for the considered RPC-based PET camera in terms of convergence and artifacts. The application of the real-time capable back projection method Direct TOF for the RPCbased PET camera resulted in an image quality comparable to the one achieved with the iterative algorihms. In total, this study does not indicate the further investigation of RPC-based PET cameras with similar efficiency for in-beam PET application. To sum up, simulation studies were performed aimed at the progress of in-vivo dosimetry. Regarding the modeling of the beta+-emitter production and prompt gamma-ray emissions, different simulation codes were evaluated. HIBRAC could be a basis for clinical PT-PET simulations, however, a detailed validation of the underlying cross section models is required. Several recommendations for the optimization of a Compton Camera prototype resulted from systematic variations of the setup. Nevertheless, the definite evaluation of the feasibility of a Compton camera for PGI can only be performed by further experiments. For PT-PET, the efficiency of the detector system is the crucial factor. Due to the obtained results for the considered RPC-based PET camera, the focus should be kept to scintillator-based PET cameras for this purpose.
183

Liouville's equation and radiative acceleration in general relativity

Keane, Aidan J. January 1999 (has links)
No description available.
184

Rayonnement gamma des Noyaux Actifs de Galaxies observé aux Très Hautes Énergies avec H.E.S.S.: Études multi-longueurs d'onde et modélisation de processus radiatifs

Lenain, Jean-Philippe 01 October 2009 (has links) (PDF)
Les Noyaux Actifs de Galaxies (NAG) sont parmi les sources les plus énergétiques dans l'Univers. Certains possèdent un jet relativiste dont l'émission est purement non-thermique. Lorsque le jet est aligné avec notre ligne de visée, ces objets appelés "blazars" voient leur émission amplifiée par effet Doppler relativiste. Depuis l'avènement de l'astrophysique gamma aux très hautes énergies (THE; E>100 GeV), les télescopes Cherenkov comme H.E.S.S. ont observé près d'une trentaine de NAG, principalement des blazars, depuis le sol. Ils tirent parti du rayonnement Cherenkov issu des gerbes de particules secondaires engendrées par l'arrivée d'un photon gamma dans l'atmosphère terrestre, pour remonter aux propriétés du photon incident et ainsi étudier ces sources extragalactiques. Nous avons étudié l'émission gamma THE rapidement variable du blazar PKS 2155-304, dont deux éruptions majeures ont été détectées en Juillet 2006, grâce à un modèle synchrotron self-Compton (SSC) dynamique. Cette émission variable présente des propriétés extrêmes excluant certains scénarios d'émission standard des blazars. Nous avons aussi développé un modèle d'émission SSC de jets relativistes non alignés avec la ligne de visée, afin d'interpréter la découverte récente par H.E.S.S. de deux radio galaxies, M 87 et Cen A, qui prouve l'émergence d'une nouvelle famille d'émetteurs cosmiques au TeV. Nous concluons avec une étude systématique menée sur l'ensemble des NAG actuellement connus au TeV, à l'aide d'un modèle SSC stationnaire. Nous présentons des diagnostics de prédictions de densités de flux dans ces objets, pouvant être confrontés aux observations futures du Cherenkov Telescope Array (CTA).
185

Calcul des corrections radiatives à la diffusion compton virtuelle. Mesure absolue de l'énergie du faisceau d'électrons de Jefferson Lab. (Hall A) par une méthode magnétique : projet ARC

Marchand, Dominique 17 April 1998 (has links) (PDF)
Cette thèse, articulée en deux parties, présente le calcul des corrections radiatives à la diffusion Compton virtuelle (VCS) et décrit la méthode magnétique (projet ARC) adoptée dans le Hall A à Jefferson Lab. pour mesurer l'énergie absolue du faisceau d'électrons avec une précision de 10-4.<br /><br />Les expériences de diffusion Compton virtuelle nous permettent d'accéder à de nouvelles observables du proton : les polarisabilités généralisées. L'extraction de ces polarisabilités s'effectuant par comparaison des sections efficaces expérimentale et théorique, il est indispensable de contrôler avec une grande précision les erreurs systématiques et les effets radiatifs liés à l'expérience. Un calcul complet des corrections radiatives internes a donc été mené dans le cadre de l'électrodynamique quantique. Ce calcul inédit tient compte de tous les graphes contribuant à l'ordre alpha^4 au niveau de la section efficace à l'exception de ceux mettant en jeu l'échange de deux photons entre les bras leptonique et hadronique ainsi que ceux relatifs au rayonnement du proton. La méthode de régularisation dimensionnelle a été employée pour le traitement des divergences ultraviolettes et infrarouges. Après utilisation d'une procédure d'addition-soustraction, la compensation infrarouge est vérifiée. Nous avons privilégié le calcul analytique pour les intégrales les plus internes et avons eu ensuite recours à un traitement numérique spécifique. Les résultats présentés correspondent aux différentes cinématiques de l'expérience VCS qui s'est déroulée à TJNAF en 1998. <br /><br />La méthode de mesure absolue d'énergie que nous avons développée s'appuie sur la déviation magnétique, constituée de huit dipôles identiques, conduisant le faisceau de l'accélérateur au hall A expérimental. L'énergie est déterminée à partir de la mesure absolue de l'angle de déviation du faisceau dans le plan horizontal et de la mesure absolue de l'intégrale de champ magnétique le long de la déviation magnétique. La mesure de l'angle de déviation se décompose en une mesure ponctuelle d'un angle de référence (par une méthode optique d'autocollimation) et en une mesure « en ligne » des déviations angulaires du faisceau par rapport à cet angle de référence (utilisation de quatre profileurs à fil : une paire en amont et une paire en aval de l'arc). L'intégrale de champ absolue le long de la déviation résulte, elle, de la mesure ponctuelle de la somme des intégrales de champ relatives des huit dipôles de l'arc par rapport à un aimant de référence et de la mesure « en ligne » de l'intégrale de champ de cet aimant de référence alimenté en série avec les huit autres de l'arc.
186

Dispositif expérimental pour la diffusion compton virtuelle dans le régime profondément inélastique dans le Hall A au Jefferson Laboratory

Camsonne, A. 04 November 2005 (has links) (PDF)
L'expérience de diffusion Compton profondément virtuelle sur le proton (DVCS) du Hall A a pris le faisceau d'électrons de 5.757 GeV polarisé du Jefferson Laboratory de septembre à décembre 2004. Elle a utilisé un spectromètre à haute résolution associé à un calorimétre électromagnétique en fluorure de plomb et à un detecteur de protons tous deux spécialement con\c cus pour fonctionner à une haute luminosité de 10^37cm^-2s^-1 permettant de signer les<br />événements exclusifs sans ambiguïté. Trois mesures ont été effectuées a x_bjorken=0.32 constant pour 3 valeurs de Q^2 : 1.5 GeV^2, 1.91GeV^2, 2.32 GeV^2. Une électronique dédiée a aussi été mise en place permettant de résoudre l'empilement durant l'analyse ainsi q'un module de coïncidence électron photon. Les données de la cinématique à 2.32 GeV^2 et s=5.6GeV^2 ont permis d'extraire un résultat préliminaire pour la section efficace d'électroproduction exclusive de pi^0 sur le proton.
187

Etude des propriétés spectrales et de la variabilité de l'emission gamma supérieure à 250 GeV des noyaux actifs de galaxies de type blazar observés dans le cadre de l'expérience C.A.T.

Piron, Frédéric 09 May 2000 (has links) (PDF)
Après un rappel des principaux enjeux de l'astronomie y des hautes énergies, l'imageur C.A.T. ("Cerenkov Array at Thémis") est présenté, l'accent étant mis sur les résultats récents de calibration, qui est un aspect particulièrement délicat des détecteurs à effet Tcherenkov atmosphérique: aucune calibration directe n'étant possible, la maîtrise du télescope doit passer par une confrontation constante des résultats obtenus sur la base de modélisations numériques et de données réelles, dont celles prises sur la source de référence qu'est la nébuleuse du Crabe. Au fil de leur présentation, les procédures d'extraction du signal gamma et de reconstruction de spectres sont ainsi testées et validées. Les résultats d'observation des blazars Markarian 501 et Markarian 421 sont ensuite exposés: une corrélation entre l'émission de rayons X (> keV) et de gamma au TeV est établie pour ces deux sources; au TeV, une rapide variabilité est observée, parfois à l'échelle de l'heure pour Markarian 421; Markarian 501 apparaît cependant plus extrême: son maximum de puissance est atteint vers 500 GeV, et un durcissement spectral est mis en évidence lors des sursauts les plus intenses. Tous ces résultats consolident la séquence spectrale récemment proposée pour unifier la classe des blazars; ils suggèrent une zone d'émission très compacte (N10-3 parsec), se propageant à vitesse relativiste à la base des jets radio de ces objets, et contenant une unique population d'électrons responsables de l'émission non thermique observée sur un large domaine de longueur d'onde. Un modèle de type Synchrotron Self-Compton est appliqué avec succès aux données prises sur Markarian 501 en Avril 1997. Enfin, la recherche de signal en provenance de 20 autres blazars candidats au TeV est entreprise, et aboutit à une limite supérieure à l'émission gamma de chacun d'eux.
188

Étude et modélisation des noyaux actifs de galaxie les plus énergétiques avec le satellite Fermi

Sanchez, David 24 June 2010 (has links) (PDF)
Lancé le 11 juin 2008 par la NASA, le satellite \textit{Fermi}, avec à son bord le LAT (Large Area Telescope), ouvre une nouvelle fenêtre sur le ciel gamma. Grâce à aux capacités de détection du LAT des photons dans la gamme en énergie 200 MeV-300 GeV, il devient possible d'étudier les Noyaux Actifs de Galaxie (NAG en anglais). En particulier, on s'intéressera à la classe des blazars et les plus énergétiques d'entres-eux les High frequency peaked BL Lac (HBL). Les blazars sont des NAG possédant un jet qui pointe dans la direction de la Terre. Cette thèse présente une étude systématique des blazars détectés par les observatoires Tcherenkov au dessus de 200 GeV, faite avec 5.5 mois de données prisent par le LAT. La comparaison entre les deux gammes en énergie permet d'étudier la distribution des particules émettrices ainsi que des effets de propagation des photons de la source jusqu'à l'observateur. Un modèle d'émission électromagnétique des jets de plasma dit synchrotron self-Compton (SSC) est décrit et utilisé pour rendre compte de l'émission sur tout le spectre des HBL PKS 2155-305 et PG 1553+113. Les résultats indiquent que les effets Klein-Nishina de réduction de la section efficace de diffusion Compton inverse jouent un rôle majeur dans ces objets. Une étude sur le long terme (environ 1 an) de PKS 2155-305 en rayons X et en rayons gamma est aussi décrite. Menée avec le satellite RXTE (rayons X) et le LAT, c'est la campagne d'observation conjointe la plus longue à ce jour. Les propriétés spectrales et temporelles sont décrites avec un modèle SSC dépendant du temps.
189

Exploration de la diffusion Compton profondément virtuelle sur le neutron dans le hall A du Jefferson Laboratory

Mazouz, Malek 08 December 2006 (has links) (PDF)
Les distributions généralisées de partons (GPDs) sont des fonctions universelles permettant une meilleure compréhension des propriétés des nucléons en termes de quarks et de gluons. La diffusion Compton profondément virtuelle (DVCS) est le processus le pus simple permettant leur mesure. En particulier, le DVCS sur le neutron est sensible à la GPD E qui est la moins contrainte à ce jour et dont la connaissance s'avère indispensable pour accéder au moment angulaire des quarks. La première expérience dédiée au DVCS sur le neutron a eu lieu fin 2004 au Hall A du Jefferson Lab. La haute luminosité de l'expérience et le taux de bruit de fond qui en découle ont nécessité le développement d'équipements spécifiques qui sont décrits. Les méthodes d'analyse utilisées sont présentées et les résultats de l'expérience conduisant à des contraintes préliminaires sur la GPD E sont discutés.
190

Electron beam dynamics with and without Compton back scattering

Drebot, Illya 07 November 2013 (has links) (PDF)
This thesis introduce my work on transverse and longitudinal non linear dynamics of an electron beam in ThomX, a novel X-ray source based on Compton backscattering. In this work I implemented in simulation code theoretical models to calculate transverse and longitudinal non linear dynamics under Compton back scattering. The processes studied include collective effect such as longitudinal space charge, resistive wall and coherent synchrotron radiation, intra beam scattering. I also implemented a longitudinal feedback algorithm and studied the effect of the feedback's delay in the simulation to explore its effects on beam dynamics. This code allows to perform a full 6D simulation of the beam dynamics in a ring under Compton back scattering taking into account the feedback stabilisation for the 400 000 turns (~ 20 ms) of one injection cycle. One important feature is that this simulation code can be run on a computer farm. Using this code I investigated the electrons dynamics in ThomX and the flux of scattered Compton photons. I analysed the relative contribution of each physical phenomena to the overall beam dynamics and how to mitigate their disruptive effect. As part of my work on longitudinal phase feedback I also measured and analysed properties of the ELETTRA RF cavity to be used on ThomX.

Page generated in 0.0518 seconds