• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 100
  • 40
  • 24
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 61
  • 52
  • 39
  • 31
  • 31
  • 28
  • 24
  • 23
  • 22
  • 19
  • 17
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Mary Seton Watts : artist, activist, feminist

Audette Sabourin, Camille 08 1900 (has links)
Mary Seton Watts (1849–1938) était une artiste et une activiste importante de la fin du 19e siècle et du début du 20e en Angleterre. Bien qu’elle ait connu un grand succès de son vivant, l’histoire n’a su assurer l’héritage de cette femme. Le Royal Victoria College de l’Université McGill à Montréal abrite Our Lady of the Snows, une bannière en soie brodée par l’artiste, accrochée dans l’anonymat dans un couloir. La bannière fut commandée par le gouverneur général du Canada Lord Grey, en 1907, dans un effort d’assurer dans le système universitaire canadien une présence impériale. Il a ainsi fait la commande d’une série de bannière à des dames de la société anglaise, leur demandant spécifiquement l’inclusion d’une image de Saint George et le dragon. Seulement, des deux bannières envoyées par Mary Seton Watts, aucune ne présentait cette imagerie. Alors que Our Lady of the Snows a été envoyée à l’institution féminine Royal Victoria à Montréal, l’autre, Spirit of the Flowers of the Nation, n’a pas été incluse dans les envois du gouverneur général. Ce mémoire vise à positionner Our Lady of the Snows à l’intersection de l’activisme féministe et de l’activité artistique de Mary Seton Watts. Tout au long de sa carrière, l’artiste a démontré que sa vision personnelle et son occupation professionnelle existaient en symbiose dans son esprit. Elle a, à la fois, utilisé son art dans ses efforts d’améliorer le monde autour d’elle et a puisé inspiration dans ses valeurs personnelles afin de construire un langage symbolique qui lui est propre. Peintre, potière, brodeuse, designer, entrepreneure, activiste et suffragiste, Mary Seton Watts a laissé un vaste héritage qui se caractérise par son habileté d’adaptation et son refus de se plier aux normes artistiques et sociales. L’artiste a produit cette bannière à un moment crucial du suffrage des femmes, où des bannières de nature similaire étaient utilisées comme outils de revendication. Par une analyse technique et symbolique détaillée de Our Lady of the Snows, ce mémoire démontre que l’œuvre est inscrite dans la foulée de ces bannières suffragistes, et comme un objet caractéristique du mariage entre art et activisme chez Mary Seton Watts. / Mary Seton Watts (1849-1938) was an important artist and activist of late nineteenth-century and early twentieth-century England. Although she was successful in her lifetime, her legacy has been forgotten through time. McGill University’s Royal Victoria College in Montreal houses Our Lady of the Snows, a banner designed and embroidered by Seton Watts. The banner is hung unidentified in the hallways of the building which now serves as university housing. Our Lady of the Snows was part of a commission from the then governor general of Canada, Lord Grey in 1906. This project was in accordance to Lord Grey’s wish to instill an imperial presence within Canadian universities. He ordered a series of embroidered banners from English gentlewomen and specifically requested they depict Saint George and the Dragon. However, of the two banners he received from Seton Watts, neither included the theme he had asked for. While Our Lady of the Snows was sent to Montreal, Spirit of the Flowers of the Nation was never displayed as part of his project. This thesis sets out to position Our Lady of the Snows at the intersection of Seton Watts’s feminist activism and artistic activity. Throughout her career, she exhibited how her art and values formed a symbiotic relationship. She used art in service of her social engagement and let her political beliefs transpire in her extensive symbolic language. Painter, potter, needleworker, designer, entrepreneur, activist and suffragist, Mary Seton Watts left a legacy that is extraordinary in its refusal to submit to artistic and societal expectations. She created this banner at a crucial moment in the history of the movement for women’s suffrage. Banners were becoming an iconic symbol of suffragist processions and were used to reclaim needlework while fighting for women’s rights. A close technical and symbolic reading of the banner positions the object as in direct dialogue with suffragist banners, as well as an emblematic demonstration of the union of art and activism in the work of Mary Seton Watts.
172

Amplification passive d'un laser à fibre optique dans une cavité Fabry-Perot : application à la production de rayonnement gamma par diffusion Compton inverse / Passive amplification of a fiber laser in a Fabry-Perot cavity : application to gamma-ray production by Compton backscattering

Labaye, François 03 December 2012 (has links)
La nécessité de prouver l’existence de nouvelles particules comme les quarks et le boson de Higgs a entrainé le développement de deux nouveaux pans de la recherche : la physique des hautes énergies ou physique des particules, dédiée à prouver expérimentalement l'existence de ces particules puis à étudier leurs propriétés et la physique des accélérateurs, dédiée au développement de nouveaux instruments pour la physique des hautes énergies.Dans ce contexte, des collisionneurs linéaires électrons/positrons polarisés de forte luminosité dont l'énergie serait connue et accordable pourrait permettre d’étudier plus finement des particules se situant dans des énergies autour du TeV telles que le Boson de Higgs. C'est dans ce sens que le projet International Linear Collider (ILC) est conçu et c'est dans le cadre du développement de ce collisionneur linéaire de particules que cette thèse de doctorat se situe. Un des points critiques de l'ILC est la source de positrons polarisés. Sans entrer dans des explications sur la physique du processus de création de positrons polarisés, nous précisons simplement que ceux-ci sont créés lorsque des rayons gamma polarisés circulairement interagissent avec la matière. Le point critique est donc la source de rayons gamma polarisés circulairement. Une alternative pour cette source est la diffusion Compton inverse et c'est finalement dans le cadre de la recherche et du développement de systèmes lasers de fortes puissances moyennes asservis à des cavités Fabry-Perot pour la production de rayons gamma polarisés par diffusion Compton inverse que se situe cette thèse.Dans un premier temps, nous posons plus précisément le contexte de cette thèse, le principe de la diffusion Compton inverse ainsi que le choix d’une architecture optique basée sur un laser fibré et une cavité Fabry-Perot. Nous finissons sur une énumération des différentes applications possibles de la diffusion Compton inverse montrant que les travaux présentés pourraient bénéficier de transfert technologique vers d’autres domaines. Dans un second temps, nous présentons les différentes architectures d’amplification laser fibrée étudiées ainsi que les résultats obtenus. Dans un troisième temps, nous faisons un rappel du principe de fonctionnement d’une cavité Fabry-Perot et présentons celle utilisée pour notre expérience ainsi que ses spécificités. Dans un quatrième temps, nous abordons l’expérience de diffusion Compton inverse qui nous a permis de présenter pour la première fois à notre connaissance l’utilisation conjointe d’un laser à fibre optique et d’une cavité Fabry-Perot dans le cadre d’un accélérateur de particules pour générer des rayons gamma. Le dispositif expérimental ainsi que les résultats obtenus sont alors présentés. Finalement, nous résumons les résultats présentés dans ce manuscrit et proposons différentes possibilités d’évolution pour le système dans une conclusion générale. / The requirement to prove the existence of news particles like quarks and the Higgs boson has led the development of two news branches for the research: the high energy physics or particle physics, dedicated to experimentally prove the existence of these new particles then to study their properties and the accelerator physics, dedicated to develop particles accelerators for the high energy physic. In this context, polarized electrons/positrons high luminosity linear collider of known and scalable energy might enable more precise studies of particles with energy around the TeV such as the Higgs boson. To that end, the International Linear Collider (ILC) project is being designed and it is in this framework that this PhD thesis takes place. One of the critical points of the ILC is the polarized positrons source. Without going through further explanation on the physical process of polarized positrons production, we point out that they are produced when circularly polarized gamma rays interact with mater. Thus, the critical point is the circularly polarized gamma-ray source. A technical solution for this source is the Compton backscattering and in the end, this thesis takes place in the framework of R&D for high average power laser systems enslaved to Fabry-Perot cavities for polarized gamma-ray production by Compton backscattering. In the first part, we present this thesis context, the Compton backscattering principle and the choice for an optical architecture based on a fiber laser and a Fabry-Perot cavity. We finish by enumerating several possible applications for Compton backscattering which shows that the work presented here might benefits from technology transfer through others research fields. In the second part, we present the different fiber laser architecture studied as well as the results obtained. In the third part, we remind the operating principle of a Fabry-Perot cavity and present the one used for our experiment as well as its specificities. In the fourth part, we address the Compton backscattering experiment which enables us to present the joint utilization of a fiber laser and a Fabry-Perot cavity in a particles accelerator to generate gamma rays for the first time to our knowledge. The experimental apparatus as well as the results obtained are thus presented. In the end, we summarize the results presented in this manuscript and propose different evolution possibilities for the system in a general conclusion.
173

Electron beam dynamics with and without Compton back scattering / La dynamique des paquets d’électrons en absence et en présence de rétrodiffusion Compton

Drebot, Illya 07 November 2013 (has links)
Ce document présente mon travail sur la dynamique transverse et longitudinale non linéaire d'un faisceau d'électrons dans ThomX, une nouvelle source de rayons X basée sur la rétrodiffusion Compton. Au cours de ce travail j'ai développé un code de simulation contenant les modèles théoriques pour calculer la dynamique non linéaire transverse et longitudinale sous l'influence de rétrodiffusion Compton. Les processus étudiés incluent les effets collectifs tels que la force de charge d'espace longitudinale, les effets de la résistivité des parois, le rayonnement synchrotron cohérent et la diffusion interne au faisceau. J'ai aussi simulé un algorithme de boucle de rétroaction longitudinale et étudié l'effet de la latence de la boucle dans les simulations pour comprendre son effet sur la dynamique du faisceau. Ce code permet d'effectuer une simulation complète en 6 dimensions de la dynamique d'un faisceau dans un anneau sous l'effet de rétrodiffusion Compton en prenant en compte la stabilisation par boucle de rétroaction pour les 400 000 tours (~ 20ms) d'un cycle d'injection. L'une des fonctionnalités importantes de ce code est qu'il peut être exécuté sur une ferme d'ordinateurs. En utilisant ce code j'ai étudié la dynamique des électrons dans ThomX et le flux de photons Compton diffusés. J'ai analysé la contribution relative de chaque phénomène physique à la dynamique globale du faisceau et comment minimiser leurs effets disruptifs. Dans le cadre de mon travail sur la boucle de rétroaction sur la phase longitudinale j'ai aussi mesuré et analysé les propriétés de la cavité RF ELETTRA à utiliser sur ThomX. / This thesis introduce my work on transverse and longitudinal non linear dynamics of an electron beam in ThomX, a novel X-ray source based on Compton backscattering. In this work I implemented in simulation code theoretical models to calculate transverse and longitudinal non linear dynamics under Compton back scattering. The processes studied include collective effect such as longitudinal space charge, resistive wall and coherent synchrotron radiation, intra beam scattering. I also implemented a longitudinal feedback algorithm and studied the effect of the feedback’s delay in the simulation to explore its effects on beam dynamics. This code allows to perform a full 6D simulation of the beam dynamics in a ring under Compton back scattering taking into account the feedback stabilisation for the 400 000 turns (~ 20 ms) of one injection cycle. One important feature is that this simulation code can be run on a computer farm. Using this code I investigated the electrons dynamics in ThomX and the flux of scattered Compton photons. I analysed the relative contribution of each physical phenomena to the overall beam dynamics and how to mitigate their disruptive effect. As part of my work on longitudinal phase feedback I also measured and analysed properties of the ELETTRA RF cavity to be used on ThomX.
174

Polarized Compton Scattering off the Nucleon / Polarisierte Compton-Streuung am Nukleon

Lee, Nan Young 27 June 2001 (has links)
No description available.
175

Mise en oeuvre d’un démonstrateur de caméra Compton pour l’imagerie en médecine nucléaire et pour le contrôle en temps réel de l’hadronthérapie à l’aide des rayonnements gamma prompts / Development of a time-of-flight Compton camera prototype for online control of ion therapy and medical imaging

Ley, Jean-Luc 14 December 2015 (has links)
L'hadronthérapie est l'une des modalités disponibles pour traiter le cancer. Cette modalité utilise des ions légers (protons, ions carbone) pour détruire les cellules cancéreuses. De telles particules ont une précision balistique de par leur trajectoire quasi-rectiligne, leur parcours fini et le profil de dose maximum en fin de parcours, ce qui permet, par rapport à la radiothérapie conventionnelle, d'épargner les tissus sains situés à côté, en aval et en amont de la tumeur. L'un des enjeux de l'assurance qualité de cette modalité est le contrôle du positionnement de la dose déposée par les ions dans le patient. Une possibilité pour effectuer ce contrôle est d'observer les gammas prompts émis lors des réactions nucléaires induites le long du parcours des ions dans le patient. Un prototype de caméra Compton, permettant théoriquement de maximiser l'efficacité de détection des gammas prompts, est actuellement développé dans une collaboration régionale. Mon travail de thèse s'est axé autour de cette caméra et plus particulièrement sur les points suivants : i) étudier par les simulations Monte Carlo le fonctionnement du prototype en cours de construction, notamment en regard des taux de comptage attendus sur les différents types d'accélérateurs en hadronthérapie, ii) mener des études de simulation sur l'utilisation de cette caméra en imagerie clinique, iii) caractériser les détecteurs silicium du diffuseur, iv) confronter les simulations entreprises sur la réponse de la caméra avec des mesures sur faisceau à l'aide d'un démonstrateur. Il résulte que le prototype de caméra Compton développé rend possible un contrôle de la localisation du dépôt de dose en protonthérapie à l'échelle d'un spot, à condition que l'intensité clinique du faisceau de protons soit diminuée d'un facteur 200 (intensité de 108 protons/s). Une application de la caméra Compton en médecine nucléaire semble réalisable avec l'utilisation de radioisotopes d'énergie supérieure à 300 keV. Ces premiers résultats doivent être confirmés par des simulations plus réalistes (cibles de PMMA homogènes et hétérogènes). Des tests avec l'intégration progressive de tous les éléments de la caméra vont avoir lieu courant 2016 / Hadrontherapy is one of the modalities available for treating cancer. This modality uses light ions (protons, carbon ions) to destroy cancer cells. Such particles have a ballistic accuracy thanks to their quasi-rectilinear trajectory, their path and the finished profile maximum dose in the end. Compared to conventional radiotherapy, this allows to spare the healthy tissue located adjacent downstream and upstream of the tumor. One of this modality’s quality assurance challenges is to control the positioning of the dose deposited by ions in the patient. One possibility to perform this control is to detect the prompt gammas emitted during nuclear reactions induced along the ion path in the patient. A Compton camera prototype, theoretically allowing to maximize the detection efficiency of the prompt gammas, is being developed under a regional collaboration. This camera was the main focus of my thesis, and particularly the following points : i) studying, throughout Monte Carlo simulations, the operation of the prototype in construction, particularly with respect to the expected counting rates on the different types of accelerators in hadrontherapy ii) conducting simulation studies on the use of this camera in clinical imaging, iii) characterising the silicon detectors (scatterer) iv) confronting Geant4 simulations on the camera’s response with measurements on the beam with the help of a demonstrator. As a result, the Compton camera prototype developed makes a control of the localization of the dose deposition in proton therapy to the scale of a spot possible, provided that the intensity of the clinical proton beam is reduced by a factor 200 (intensity of 108 protons / s). An application of the Compton camera in nuclear medicine seems to be attainable with the use of radioisotopes of an energy greater than 300 keV. These initial results must be confirmed by more realistic simulations (homogeneous and heterogeneous PMMA targets). Tests with the progressive integration of all camera elements will take place during 2016
176

Simulation et reconstruction 3D à partir de caméra Compton pour l’hadronthérapie : Influence des paramètres d’acquisition / Simulation and reconstruction from Compton caméra for hadrontherapy : Influence of the acquisition parameters

Hilaire, Estelle 18 November 2015 (has links)
L'hadronthérapie est une méthode de traitement du cancer qui emploie des ions (carbone ou proton) au lieu des rayons X. Les interactions entre le faisceau et le patient produisent des radiations secondaires. Il existe une corrélation entre la position d'émission de certaines de ces particules et la position du pic de Bragg. Parmi ces particules, des gamma-prompt sont produits par les fragments nucléaires excités et des travaux actuels ont pour but de concevoir des systèmes de tomographie par émission mono-photonique capable d'imager la position d'émission ces radiations en temps réel, avec une précision millimétrique, malgré le faible nombre de données acquises. Bien que ce ne soit pas actuellement possible, le but in fine est de surveiller le dépôt de dose. La caméra Compton est un des système TEMP qui a été proposé pour imager ce type de particules, car elle offre une meilleure résolution énergétique et la possibilité d'avoir une image 3D. Cependant, en pratique l'acquisition est affectée par le bruit provenant d'autres particules secondaires, et les algorithmes de reconstruction des images Compton sont plus compliqués et encore peu aboutis, mais sur une bonne voie de développement. Dans le cadre de cette thèse, nous avons développé une chaîne complète allant de la simulation de l'irradiation d'un fantôme par un faisceau de protons allant jusqu'à la reconstruction tomographique des images obtenues à partir de données acquises par la caméra Compton. Nous avons étudié différentes méthodes de reconstruction analytiques et itératives, et nous avons développé une méthode de reconstruction itérative capable de prendre en compte les incertitudes de mesure sur l'énergie. Enfin nous avons développé des méthodes pour la détection de la fin du parcours des distributions gamma-prompt reconstruites. / Hadrontherapy is a cancer treatment method which uses ions (proton or carbon) instead of X-rays. Interactions between the beam and the patient produce secondary radiation. It has been shown that there is a correlation between the emission position of some of these particles and the Bragg peak position. Among these particles, prompt-gamma are produced by excited nuclear fragments and current work aims to design SPECT systems able to image the emission position the radiation in real time, with a millimetric precision, despite the low data statistic. Although it is not currently possible, the goal is to monitor the deposited dose. The Compton camera is a SPECT system that proposed for imaging such particles, because it offers a good energy resolution and the possibility of a 3D imaging. However, in practice the acquisition is affected by noise from other secondary particles and the reconstruction algorithms are more complex and not totally completed, but the developments are well advanced. In this thesis, we developed a complete process from the simulation of irradiation of a phantom by a proton beam up to the tomographic reconstruction of images obtained from data acquired by the Compton camera. We studied different reconstruction methods (analytical and iterative), and we have developed an iterative method able to consider the measurement uncertainties on energy. Finally we developed methods to detect the end-of-range of the reconstructed prompt-gamma distributions.
177

Image reconstruction for Compton camera with application to hadrontherapy / Reconstruction d'images pour la caméra Compton avec application en hadronthérapie

Lojacono, Xavier 26 November 2013 (has links)
La caméra Compton est un dispositif permettant d’imager les sources de rayonnement gamma. Ses avantages sont sa sensibilité (absence de collimateur mécanique) et la possibilité de reconstruire des images 3D avec un dispositif immobile. Elle également adaptée pour des sources à large spectre énergétique. Ce dispositif est un candidat prometteur en médecine nucléaire et en hadronthérapie. Ces travaux, financés par le projet européen ENVISION (European NoVel Imaging Systems for ION therapy) Coopération-FP7, portent sur le développement de méthodes de reconstruction d’images pour la caméra Compton pour la surveillance de la thérapie par ions. Celle-ci nécessite idéalement une reconstruction temps réel avec une précision millimétrique, même si le nombre de données acquises est relativement faible. Nous avons développé des méthodes analytiques et itératives. Leurs performances sont analysées dans le contexte d’acquisitions réalistes (géométrie de la caméra, nombre d’événements). Nous avons développé une méthode analytique de rétroprojection filtrée. Cette méthode est rapide mais nécessite beaucoup de données. Nous avons également développé des méthodes itératives utilisant un algorithme de maximisation de la fonction de vraisemblance. Nous avons proposé un modèle probabiliste pour l’estimation des éléments de la matrice système nécessaire à la reconstruction et nous avons développé différentes approches pour le calcul de ses éléments : l’une néglige les incertitudes de mesure sur l’énergie, l’autre les prend en compte en utilisant une distribution gaussienne. Nous avons étudié une méthode simplifiée utilisant notre modèle probabiliste. Plusieurs reconstructions sont menées à partir de données simulées, obtenues avec Geant4, mais provenant aussi de plusieurs prototypes simulés de caméra Compton proposés par l’Institut de Physique Nucléaire de Lyon (IPNL) et par le Centre de recherche de Dresde-Rossendorf en Allemagne. Les résultats sont prometteurs et des études plus poussées, à partir de données encore plus réalistes, viseront à les confirmer. / The Compton camera is a device for imaging gamma radiation sources. The advantages of the system lie in its sensitivity, due to the absence of mechanical collimator, and the possibility of imaging wide energy spectrum sources. These advantages make it a promising candidate for application in hadrontherapy. Funded by the european project ENVISION, FP7-Cooperation Work Program, this work deals with the development of image reconstruction methods for the Compton camera. We developed both analytical and iterative methods in order to reconstruct the source from cone-surface projections. Their performances are analyzed with regards to the context (geometry of the camera, number of events). We developped an analytical method using a Filtered BackProjection (FBP) formulation. This method is fast but really sensitive to the noise. We have also developped iterative methods using a List Mode-Maximum Likelihood Expectation Maximization (LM-MLEM) algorithm. We proposed a new probabilistic model for the computation of the elements of the system matrix and different approaches for the calculation of these elements neglecting or not the measurement uncertainties. We also implemented a simplified method using the probabilistic model we proposed. The novelty of the method also lies on the specific discretization of the cone-surface projections. Several studies are carried out upon the reconstructions of simulated data worked out with Geant4, but also simulated data obtained from several prototypes of Compton cameras under study at the Institut de Physique Nucléaire de Lyon (IPNL) and at the Research Center of Dresden-Rossendorf. Results are promising, and further investigations on more realistic data are to be done.
178

Effets radiatifs et d'électrodynamique quantique dans l'interaction laser-matière ultra-relativiste / Radiative and quantum electrodynamics effects in extreme intensity laser-matter interaction

Lobet, Mathieu 18 December 2015 (has links)
Cette thèse a pour objet l'étude de l'interaction laser-matière dans un régime d'éclairement extrême que visent à atteindre plusieurs installations multi-pétawatt en cours de développement (CILEX-Apollon, ELI, IZEST, etc.). Pour un éclairement supérieur à 1022 Wcm-2, la dynamique relativiste des électrons accélérés dans l'onde laser est modiée par un important rayonnement Compton inverse non-linéaire. Au-delà de 1023 Wcm2, les photons ainsi produits peuvent, en interagissant à leur tour avec le champ laser, se désintégrer en paires électron-positron via le mécanisme de Breit-Wheeler non-linéaire. Ces mécanismes d'électrodynamique quantique, dont l'étude expérimentale était jusqu'ici l'apanage des grands accélérateurs de particles, peuvent grandement affecter les mécanismes usuels d'interaction laser-plasma, notamment ceux régissant l'accélération de particules chargées et, par conséquent, le bilan global de l'interaction. Afin de modéliser ce régime inédit d'interaction, qui combine processus collectifs, relativistes et d'électrodynamique quantique, nous avons enrichi des mécanismes précédents le code de simulation particle-in-cell calder développé de longue date au CEA/DIF. L'influence de ces mécanismes est d'abord explorée dans le cas d'une impulsion laser interagissant avec une cible dense de taille micrométrique. Un rendement de conversion de l'énergie laser en photons supérieur à 10% est observée au-dessus de 1023 Wcm-2, tandis que la production d'anti-matière s'emballe, via un mécanisme de cascade, à partir de 1024 Wcm2. Dans un second temps, nous étudions la génération de positrons lors de la collision frontale entre un faisceau d'électrons ultra-relativistes issu d'un accélérateur plasma et une impulsion laser ultra-intense. Dans une dernière partie, nous considérons un scénario prospectif d'intérêt astrophysique, à savoir la collision de plasmas de paires issus de cibles solides irradiées à 1024 Wcm-2 montrant la croissance rapide d'une instabilité de lamentation magnétique combinée à d'intenses effets radiatifs. / This PhD thesis is concerned with the regime of extreme-intensity laser-matter interaction that should be accessed on upcoming multi-petawatt facilities (e.g. CILEX-Apollon, ELI, IZEST). At intensities IL > 1022 Wcm-2, the relativistic dynamics of the laser-driven electrons becomes significantly modified by high-energy radiation emission through nonlinear inverse Compton scattering. For IL > 1023 Wcm-2, the emitted-ray photons can, in turn, interact with the laser field and decay into electron-positron pairs via the nonlinear Breit-Wheeler process. These quantum electrodynamic processes, which until recently could only be explored on large-scale particle accelerators, can greatly alter the "standard" mechanisms of laser-plasma interaction, and therefore its overall energy budget. In order to model their intricate interplay with the laser-induced plasma processes, they have been implemented within the particle-in-cell code calder developed at CEA. In a first part, we study these QED processes in the interaction of an ultra-intense laser with a micrometric overdense target. It is found that the laser-to--ray energy conversion efficiency can by far exceed 10% for intensities IL > 1023 Wcm-2, while copious pair production (through pair cascading) kicks in for IL > 1024 Wcm-2. In a second part, we consider positron generation in the collision between a GeV electron bunch issued from a laser-wake eld accelerator and a counterpropagating laser pulse. In a third part, we analyze a prospective scheme of astrophysical interest, consisting in the collision between two dense pair plasmas produced from solid targets irradiated at 1024 Wcm-2 showing a fast-growing magnetic lamentation instability amplified by intense synchrotron emission.
179

Mesure de la section efficace d'électroproduction de photons sur le neutron à Jefferson Lab en vue de la séparation du terme de diffusion Compton profondément virtuelle / Measurement of the photon electroproduction cross section off the neutron at Jefferson Lab in view of the separation of the deeply virtual Compton scattering term

Desnault, Camille 17 September 2015 (has links)
La section efficace d'électroproduction de photons sur le nucléon est proportionnelle aux amplitudes au carré de diffusion Compton profondément virtuelle (DVCS) et du Bethe-Heitler ainsi qu'un terme d'interférence de ces deux processus. Sa mesure sur le neutron fut réalisée dans le cadre de l'expérience E08-025 qui s'est déroulée en 2010 dans le Hall A à Jefferson Lab (USA). Par une forte sensibilité au terme d'interférence, elle aura permis l'extraction de trois observables dépendantes des Distributions Généralisées de Partons (GPDs), ainsi que la perspective de séparer par une méthode Rosenbluth le terme |DVCS|².Les GPDs sont des fonctions de structure qui nous permettent de comprendre la structure interne des nucléons en terme de corrélation entre les distributions en position transverse et en impulsion longitudinale des quarks au sein du nucléon. Plus qu'un moyen d'accéder à une image tri-dimensionnelle de la composition élémentaire du nucléon, la détermination des GPDs du neutron permettrait par la règle de somme de Ji l'accès au moment angulaire des quarks dans le nucléon, la pièce manquante à la compréhension du mystère lié au spin du nucléon.Cette thèse aborde le contexte théorique de la mesure de la section efficace d'électroproduction de photons sur le neutron, puis une description de la configuration expérimentale utilisée pour sa réalisation. Elle expose la sélection des données d'intérêt pour cette mesure et présente les résultats obtenus par une méthode d'ajustement des données à une simulation Monte Carlo dont la démarche est expliquée en détails. Pour finir, une étude systématique des résultats achève ce manuscrit. / The photon electroproduction cross section off the nucleon is proportional to the deeply virtual Compton scattering (DVCS) and Bethe-Heitler amplitudes squared together with an interference term between these two processes. Its measurement on the neutron has been performed in the framework of the E08-025 experiment which took place in 2010 in Hall A at Jefferson Lab (USA). Thanks to a high sensibility to the interference term, it made possible the extraction of three Generalized Parton Distributions (GPDs) dependent observables, as well as the prospect to extract the |DVCS|² term through a Rosenbluth separation.The GPDs are structure functions which allow to understand the internal structure of nucleons in term of the correlation between transverse spatial and longitudinal momentum distributions of quarks inside the nucleon. More than a way to access a three-dimensional picture of the elementary arrangement of the nucleon, the measurement of GPDs on the neutron would give access by the Ji's sum rule to the angular momentum of quarks in the nucleon, the missing piece for the understanding of the nucleon spin puzzle.This thesis outlines the theoretical context of the measurement of the photon electroproduction cross section off the neutron, and the experimental setup used for its achievement. It describes the selection of the experimental data of interest for this measurement and presents the results obtained from a fitting method of data to a Monte Carlo simulation, which is explained in detail. Finally, a systematic study of the results completes this manuscript.
180

Nuclear methods for real-time range verification in proton therapy based on prompt gamma-ray imaging

Hueso González, Fernando 07 June 2016 (has links)
Accelerated protons are excellent candidates for treating several types of tumours. Such charged particles stop at a defined depth, where their ionisation density is maximum. As the dose deposit beyond this distal edge is very low, proton therapy minimises the damage to normal tissue compared to photon therapy. Nonetheless, inherent range uncertainties cast doubts on the irradiation of tumours close to organs at risk and lead to the application of conservative safety margins. This constrains significantly the potential benefits of proton over photon therapy and limits its ultimate aspirations. Prompt gamma rays, a by-product of the irradiation that is correlated to the dose deposition, are reliable signatures for the detection of range deviations and even for three-dimensional in vivo dosimetry. In this work, two methods for Prompt Gamma-ray Imaging (PGI) are investigated: the Compton camera (Cc) and the Prompt Gamma-ray Timing (PGT). Their applicability in a clinical scenario is discussed and compared. The first method aspires to reconstruct the prompt gamma ray emission density map based on an iterative imaging algorithm and multiple position sensitive gamma ray detectors. These are arranged in scatterer and absorber plane. The second method has been recently proposed as an alternative to collimated PGI systems and relies on timing spectroscopy with a single monolithic detector. The detection times of prompt gamma rays encode essential information about the depth-dose profile as a consequence of the measurable transit time of ions through matter. At Helmholtz-Zentrum Dresden-Rossendorf (HZDR) and OncoRay, detector components are characterised in realistic radiation environments as a step towards a clinical Cc. Conventional block detectors deployed in commercial Positron Emission Tomography (PET) scanners, made of Cerium-doped lutetium oxyorthosilicate - Lu2SiO5:Ce (LSO) or Bismuth Germanium Oxide - Bi4Ge3O12 (BGO) scintillators, are suitable candidates for the absorber of a Cc due to their high density and absorption efficiency with respect to the prompt gamma ray energy range (several MeV). LSO and BGO block detectors are compared experimentally in clinically relevant radiation fields in terms of energy, spatial and time resolution. On a different note, two BGO block detectors (from PET scanners), arranged as the BGO block Compton camera (BbCc), are deployed for simple imaging tests with high energy prompt gamma rays produced in homogeneous Plexiglas targets by a proton pencil beam. The rationale is to maximise the detection efficiency in the scatterer plane despite a moderate energy resolution. Target shifts, increase of the target thickness and beam energy variation experiments are conducted. Concerning the PGT concept, in a collaboration among OncoRay, HZDR and IBA, the first test at a clinical proton accelerator (Westdeutsches Protonentherapiezentrum Essen) with several detectors and heterogeneous phantoms is performed. The sensitivity of the method to range shifts is investigated, the robustness against background and stability of the beam bunch time profile is explored, and the bunch time spread is characterised for different proton energies. With respect to the material choice for the absorber of the Cc, the BGO scintillator closes the gap with respect to the brighter LSO. The reason behind is the high energies of prompt gamma rays compared to the PET scenario, which increase significantly the energy, spatial and time resolution of BGO. Regarding the BbCc, shifts of a point-like radioactive source are correctly detected, line sources are reconstructed, and one centimetre proton range deviations are identified based on the evident changes of the back projection images. Concerning the PGT experiments, for clinically relevant doses, range differences of five millimetres in defined heterogeneous targets are identified by numerical comparison of the spectrum shape. For higher statistics, range shifts down to two millimetres are detectable. Experimental data are well reproduced by analytical modelling. The Cc and the PGT are ambitious approaches for range verification in proton therapy based on PGI. Intensive detector characterisation and tests in clinical facilities are mandatory for developing robust prototypes, since the energy range of prompt gamma rays spans over the MeV region, not used traditionally in medical applications. Regarding the material choice for the Cc: notwithstanding the overall superiority of LSO, BGO catches up in the field of PGI. It can be considered as a competitive alternative to LSO for the absorber plane due to its lower price, higher photoabsorption efficiency, and the lack of intrinsic radioactivity. The results concerning the BbCc, obtained with relatively simple means, highlight the potential application of Compton cameras for high energy prompt gamma ray imaging. Nevertheless, technical constraints like the low statistics collected per pencil beam spot (if clinical currents are used) question their applicability as a real-time and in vivo range verification method in proton therapy. The PGT is an alternative approach, which may have faster translation into clinical practice due to its lower price and higher efficiency. A proton bunch monitor, higher detector throughput and quantitative range retrieval are the upcoming steps towards a clinically applicable prototype, that may detect significant range deviations for the strongest beam spots. The experimental results emphasise the prospects of this straightforward verification method at a clinical pencil beam and settle this novel approach as a promising alternative in the field of in vivo dosimetry.:1 Introduction 1.1 Proton therapy 1.1.1 The beginnings 1.1.2 Essential features 1.1.3 Advantages and drawbacks 1.2 Range uncertainties and their consequences 1.3 Range verification methods 1.4 Prompt gamma-ray imaging 1.4.1 Passive collimation 1.4.2 Active collimation 1.4.3 Correlation to dose 1.5 Aim of this work 2 Compton camera 2.1 Theoretical background 2.1.1 Compton formula and Klein-Nishina cross section 2.1.2 Detection principle 2.1.3 Intersection of cone surface and plane 2.1.4 Practical considerations 2.2 Motivation 2.3 Goals 2.4 Materials 2.4.1 Scintillator properties 2.4.2 Block detector properties 2.4.3 Electronics and data acquisition 2.4.4 High efficiency Compton camera setup 2.5 Experimental setup 2.5.1 Accelerators 2.5.2 Detector setup 2.5.3 Trigger regime 2.6 Methods 2.6.1 Energy calibration 2.6.2 Spatial calibration 2.6.3 Time calibration 2.6.4 Error analysis 2.6.5 Systematic measurement program 2.7 Results – absorber choice 2.7.1 Energy resolution 2.7.2 Spatial resolution 2.7.3 Time resolution 2.8 Discussion – absorber choice 2.9 Results – BbCc setup 2.10 Discussion – BbCc setup 3 Prompt gamma-ray timing 3.1 Theoretical background 3.1.1 Detection principle 3.1.2 Kinematics 3.1.3 Detector model 3.1.4 Quantitative assessment 3.2 Goals 3.3 Materials 3.3.1 Detectors 3.3.2 Electronics 3.3.3 Accelerators 3.4 Methods 3.4.1 Detector and module settings 3.4.2 Proton bunch phase stability 3.4.3 Proton bunch time structure 3.4.4 Systematic measurement program 3.4.5 Data acquisition rate 3.4.6 Data analysis 3.4.7 Modelling of PGT spectra 3.5 Results 3.5.1 Intrinsic detector time resolution 3.5.2 Illustrative energy over time spectra 3.5.3 Proton bunch phase stability 3.5.4 Proton bunch time structure 3.5.5 Systematic measurement program 3.6 Discussion 3.7 Conclusions 4 Discussion 4.1 Detector load, event throughput and spot duration 4.2 Comparison of PGI systems 4.3 Summary 4.4 Zusammenfassung Bibliography / Beschleunigte Protonen sind ausgezeichnete Kandidaten für die Behandlung von diversen Tumorarten. Diese geladenen Teilchen stoppen in einer bestimmten Tiefe, bei der die Ionisierungsdichte maximal ist. Da die deponierte Dosis hinter der distalen Kante sehr klein ist, minimiert die Protonentherapie den Schaden an normalem Gewebe verglichen mit der Photonentherapie. Inhärente Reichweitenunsicherheiten stellen jedoch die Bestrahlung von Tumoren in der Nähe von Risikoorganen in Frage und führen zur Anwendung von konservativen Sicherheitssäumen. Dadurch werden die potentiellen Vorteile der Protonen- gegenüber der Photonentherapie sowie ihre letzten Ziele eingeschränkt. Prompte Gammastrahlung, ein Nebenprodukt der Bestrahlung, welche mit der Dosisdeposition korreliert, ist eine zuverlässige Signatur um Reichweitenunterschiede zu detektieren und könnte sogar für eine dreidimensionale in vivo Dosimetrie genutzt werden. In dieser Arbeit werden zwei Methoden für Prompt Gamma-ray Imaging (PGI) erforscht: die Compton-Kamera (CK) und das Prompt Gamma-ray Timing (PGT)-Konzept. Des Weiteren soll deren Anwendbarkeit im klinischen Szenario diskutiert und verglichen werden. Die erste Methode strebt nach der Rekonstruktion der Emissionsdichtenverteilung der prompten Gammastrahlung und basiert auf einem iterativen Bildgebungsalgorithmus sowie auf mehreren positionsempfindlichen Detektoren. Diese werden in eine Streuer- und Absorberebene eingeteilt. Die zweite Methode ist vor Kurzem als eine Alternative zu kollimierten PGI Systemen vorgeschlagen worden, und beruht auf dem Prinzip der Zeitspektroskopie mit einem einzelnen monolithischen Detektor. Die Detektionszeiten der prompten Gammastrahlen beinhalten entscheidende Informationen über das Tiefendosisprofil aufgrund der messbaren Durchgangszeit von Ionen durch Materie. Am Helmholtz-Zentrum Dresden-Rossendorf (HZDR) und OncoRay werden Detektorkomponenten in realistischen Strahlungsumgebungen als ein Schritt zur klinischen CK charakterisiert. Konventionelle Blockdetektoren, welche in kommerziellen Positronen-Emissions-Tomographie (PET)-Scannern zum Einsatz kommen und auf Cer dotiertem Lutetiumoxyorthosilikat - Lu2SiO5:Ce (LSO) oder Bismutgermanat - Bi4Ge3O12 (BGO) Szintillatoren basieren, sind geeignete Kandidaten für den Absorber einer CK wegen der hohen Dichte und Absorptionseffizienz im Energiebereich von prompten Gammastrahlen (mehrere MeV). LSO- und BGO-Blockdetektoren werden in klinisch relevanten Strahlungsfeldern in Bezug auf Energie-, Orts- und Zeitauflösung verglichen. Weiterhin werden zwei BGO-Blockdetektoren (von PET-Scannern), angeordnet als BGO Block Compton-Kamera (BBCK), benutzt, um die Bildgebung von hochenergetischen prompten Gammastrahlen zu untersuchen, die in homogenen Plexiglas-Targets durch einen Protonen-Bleistiftstrahl emittiert werden. Die Motivation hierfür ist, die Detektionseffizienz der Streuerebene zu maximieren, wobei jedoch die Energieauflösung vernachlässigt wird. Targetverschiebungen, sowie Änderungen der Targetdicke und der Teilchenenergie werden untersucht. In einer Kollaboration zwischen OncoRay, HZDR and IBA, wird der erste Test des PGT-Konzepts an einem klinischen Protonenbeschleuniger (Westdeutsches Protonentherapiezentrum Essen) mit mehreren Detektoren und heterogenen Phantomen durchgeführt. Die Sensitivität der Methode hinsichtlich Reichweitenveränderungen wird erforscht. Des Weiteren wird der Einfluss von Untergrund und Stabilität des Zeitprofils des Strahlenbündels untersucht, sowie die Zeitverschmierung des Bündels für verschiedene Protonenenergien charakterisiert. Für die Materialauswahl für den Absorber der CK ergibt sich, dass sich BGO dem lichtstärkeren LSO Szintillator angleicht. Der Grund dafür sind die höheren Energien der prompten Gammastrahlung im Vergleich zum PET Szenario, welche die Energie-, Orts- und Zeitauflösung von BGO stark verbessern. Anhand von offensichtlichen Änderungen der Rückprojektionsbilder zeigt sich, dass mit der BBCK Verschiebungen einer punktförmigen radioaktiven Quelle erfolgreich detektiert, Linienquellen rekonstruiert und Verschiebungen der Protonenreichweite um einen Zentimeter identifiziert werden. Für die PGT-Experimente können mit einem einzigen Detektor Reichweitenunterschiede von fünf Millimetern für definierte heterogene Targets bei klinisch relevanten Dosen detektiert werden. Dies wird durch den numerischen Vergleich der Spektrumform ermöglicht. Bei größerer Ereigniszahl können Reichweitenunterschiede von bis zu zwei Millimetern detektiert werden. Die experimentellen Daten werden durch analytische Modellierung wiedergegeben. Die CK und das PGT-Konzept sind ambitionierte Ansätze zur Verifizierung der Reichweite in der Protonentherapie basierend auf PGI. Intensive Detektorcharakterisierung und Tests an klinischen Einrichtungen sind Pflicht für die Entwicklung geeigneter Prototypen, da der Energiebereich prompter Gammastrahlung sich über mehrere MeV erstreckt, was nicht dem Normbereich der traditionellen medizinischen Anwendungen entspricht. Im Bezug auf die Materialauswahl der CK wird ersichtlich, dass BGO trotz der allgemeinen Überlegenheit von LSO für die Anwendung im Bereich PGI aufholt. Wegen des niedrigeren Preises, der höheren Photoabsorptionseffizienz und der nicht vorhandenen Eigenaktivität erscheint BGO als eine konkurrenzfähige Alternative für die Absorberebene der CK im Vergleich zu LSO. Die Ergebnisse der BBCK, welche mit relativ einfachen Mitteln gewonnen werden, heben die potentielle Anwendung von Compton-Kameras für die Bildgebung prompter hochenergetischer Gammastrahlen hervor. Trotzdem stellen technische Beschränkungen wie die mangelnde Anzahl von Messereignissen pro Bestrahlungspunkt (falls klinische Ströme genutzt werden) die Anwendbarkeit der CK als Echtzeit- und in vivo Reichweitenverifikationsmethode in der Protonentherapie in Frage. Die PGT-Methode ist ein alternativer Ansatz, welcher aufgrund der geringeren Kosten und der höheren Effizienz eine schnellere Umsetzung in die klinische Praxis haben könnte. Ein Protonenbunchmonitor, höherer Detektordurchsatz und eine quantitative Reichweitenrekonstruktion sind die weiteren Schritte in Richtung eines klinisch anwendbaren Prototyps, der signifikante Reichweitenunterschiede für die stärksten Bestrahlungspunkte detektieren könnte. Die experimentellen Ergebnisse unterstreichen das Potential dieser Reichweitenverifikationsmethode an einem klinischen Bleistiftstrahl und lassen diesen neuartigen Ansatz als eine vielversprechende Alternative auf dem Gebiet der in vivo Dosimetrie erscheinen.:1 Introduction 1.1 Proton therapy 1.1.1 The beginnings 1.1.2 Essential features 1.1.3 Advantages and drawbacks 1.2 Range uncertainties and their consequences 1.3 Range verification methods 1.4 Prompt gamma-ray imaging 1.4.1 Passive collimation 1.4.2 Active collimation 1.4.3 Correlation to dose 1.5 Aim of this work 2 Compton camera 2.1 Theoretical background 2.1.1 Compton formula and Klein-Nishina cross section 2.1.2 Detection principle 2.1.3 Intersection of cone surface and plane 2.1.4 Practical considerations 2.2 Motivation 2.3 Goals 2.4 Materials 2.4.1 Scintillator properties 2.4.2 Block detector properties 2.4.3 Electronics and data acquisition 2.4.4 High efficiency Compton camera setup 2.5 Experimental setup 2.5.1 Accelerators 2.5.2 Detector setup 2.5.3 Trigger regime 2.6 Methods 2.6.1 Energy calibration 2.6.2 Spatial calibration 2.6.3 Time calibration 2.6.4 Error analysis 2.6.5 Systematic measurement program 2.7 Results – absorber choice 2.7.1 Energy resolution 2.7.2 Spatial resolution 2.7.3 Time resolution 2.8 Discussion – absorber choice 2.9 Results – BbCc setup 2.10 Discussion – BbCc setup 3 Prompt gamma-ray timing 3.1 Theoretical background 3.1.1 Detection principle 3.1.2 Kinematics 3.1.3 Detector model 3.1.4 Quantitative assessment 3.2 Goals 3.3 Materials 3.3.1 Detectors 3.3.2 Electronics 3.3.3 Accelerators 3.4 Methods 3.4.1 Detector and module settings 3.4.2 Proton bunch phase stability 3.4.3 Proton bunch time structure 3.4.4 Systematic measurement program 3.4.5 Data acquisition rate 3.4.6 Data analysis 3.4.7 Modelling of PGT spectra 3.5 Results 3.5.1 Intrinsic detector time resolution 3.5.2 Illustrative energy over time spectra 3.5.3 Proton bunch phase stability 3.5.4 Proton bunch time structure 3.5.5 Systematic measurement program 3.6 Discussion 3.7 Conclusions 4 Discussion 4.1 Detector load, event throughput and spot duration 4.2 Comparison of PGI systems 4.3 Summary 4.4 Zusammenfassung Bibliography

Page generated in 0.0506 seconds