• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1493
  • 30
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1553
  • 1199
  • 895
  • 812
  • 377
  • 353
  • 342
  • 326
  • 311
  • 246
  • 207
  • 180
  • 162
  • 160
  • 158
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
491

Tomografia computadorizada por feixe cônico para detecção de lesões incipientes de furca simuladas em mandíbulas suínas maceradas / Cone beam computed tomography for detection of incipient furcation invasion in pig mandibles

Otávio Shoiti Umetsubo 04 July 2011 (has links)
As radiografias intraorais ilustram bem os estágios de reabsorção periodontal nas regiões interproximais. Entretanto, a sobreposição de estruturas dificulta avaliação da perda óssea nas corticais vestibular e lingual. A tomografia computadorizada por feixe cônico (TCFC) é de elevada importância em várias especialidades odontológicas, tais como implantodontia, avaliação de lesões ósseas, estudo da articulação têmporo-mandibular e cirurgia buco-maxilo-facial. A TCFC também tem tido crescente indicação em outras áreas, como a periodontia e endodontia. O objetivo no presente estudo foi a) estabelecer o protocolo de aquisição mais adequado para a detecção de lesões incipientes de furca simuladas quimicamente; e b) avaliar a reprodutibilidade, sensibilidade e especificidade da TCFC, para a finalidade previamente citada. No presente estudo, foram utilizadas 15 mandíbulas suínas maceradas, que apresentavam o segundo molar íntegro e as corticais adjacentes preservadas As simulações de lesões em região de furca foram feitas com aplicação de ácido perclórico a 70%, em até quatro sítios possíveis em cada mandíbula (vestibular do lado direito, lingual do lado direito, vestibular do lado esquerdo, lingual do lado esquerdo) por um examinador participante que não avaliou as imagens. Nos 60 sitios possíveis, foram escolhidos aleatoriamente 20 para as simulações das lesões. Posteriormente, as mandíbulas foram submetidas à TCFC (i-CAT Next Generation) em dois. protocolos de aquição: voxel 0,2 mm e 0,25 mm, ambos com FOV de 6 cm de altura por 16 cm de diâmetro e com 26,9 segundos de tempo. Dois observadores (radiologistas previamente calibrados) avaliaram os exames duas vezes, em ordem aleatória, sob iluminação controlada. Os observadores foram orientados a direcionar a avaliação das regiões dos segundos molares, e questionados se havia lesão ou não nos sítios avaliados. A interpretação das imagens foi realizada em uma estação de trabalho independente localizada no Laboratório de Imagem em Terceira Dimensão da Faculdade de Odontologia da Universidade de São Paulo, utilizando o software Xoran (Xoran Technologies). A sensibilidade, especificidade e reprodutibilidade da TCFC foram avaliadas nos dois protocolos. A TCFC apresentou especificidade alta, sensibilidade baixa e reprodutibilidade moderada na detecção de lesões incipientes de furca. A influência do tamanho do voxel não foi estatisticamente significativa na detecção destas lesões. / Intraoral radiographs illustrate the stages of resorption in periodontal interproximal regions. However, overlapping structures hinders evaluation of bone loss in the buccal and lingual cortical plates. The cone beam computed tomography (CBCT) is of high importance in various dental specialties such as implantology, evaluation of bone lesions, the study of temporomandibular joint and maxillo-facial surgery. The CBCT has also been increasing indications in other areas, such as periodontics and endodontics. The aim of this study was to establish a) the acquisition protocol most suitable for the detection of incipient furcation invasion chemically simulated and b) assess the reproducibility, sensitivity and specificity of CBCT for the purpose previously mentioned. In this study, 15 pigs macerated mandibles were used, which showed the second molar and the adjacent cortical integrity preserved. Simulated lesions in the furcation area were made with application of 70% perchloric acid, up to four possible sites in each jaw (the right buccal, the right lingual, the left buccal, and left lingual side) by an examiner participant who did not evaluate the images. In the 60 possible sites, 20 were randomly chosen for the simulated lesions. Subsequently, the mandibles underwent cone beam computed tomography (Next Generation i-CAT) in two acquisition protocols: at 0.2 mm and 0.25 mm voxel, both with FOV of 6 cm height by 16 cm in diameter and 26.9 seconds of time. Two observers (calibrated radiologists) evaluated the examinations twice, in random order under controlled lighting. Observers were instructed to direct the evaluation to the regions of the second molars, and they were asked if there were or not injuries on those avaluated sites. Image interpretation was performed on an independent workstation located at the Third Dimension Laboratory of Image in the School of Dentistry, University of São Paulo, using the software Xoran (Xoran Technologies). The sensitivity, specificity and reproducibility of CBCT were assessed in both trials. The CBCT showed high specificity, low sensitivity and moderate reproducibility in the detection of incipient lesions, furcation. The influence of voxel size was not statistically significant in detecting these lesions.
492

\"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem\" / Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models

Mario Sergio Saddy 07 December 2006 (has links)
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica. / The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
493

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de incisivos inferiores / Internal anatomy of lower incisors evaluated by computerized microtomography

Graziela Bianchi Leoni 26 January 2012 (has links)
O conhecimento do sistema de canais radiculares (SCR) é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo deste estudo foi avaliar quantitativa e qualitativamente a anatomia do SCR de incisivos inferiores por meio de microtomografia computadorizada. A aquisição de fotomicrotomografia de 283 incisivos centrais (ICI) e 329 incisivos laterais inferiores (ILI) foi realizada por meio do microtomógrafo SkyScan modelo 1174. Estas imagens foram utilizadas para classificação do SCR de acordo com Vertucci que considera número e localização da divisão dos canais, variando do tipo I ao VIII. Da amostra inicial, 39 ICI e 35 ILI foram escaneados com resolução de 22,9 μm e reconstruídos para análises bidimensionais de: número, área, circularidade, diâmetro maior e menor a 1, 2, 3, 4 e 5 mm do forame apical; e análise tridimensional onde foram observados volume e área de superfície, número e localização de canais acessórios e classificação de acordo com Vertucci. Os resultados evidenciaram que, no terço apical, o número máximo de canais encontrados foi 3; a área aumentou progressivamente a cada milímetro avaliado; a circularidade variou entre 0,37 ± 0,21 (mínimo) e 0,52 ± 0,19 (máximo) demonstrando uma forma achatada destes canais; o diâmetro maior aumentou 95,45% nos ICI e 135,55% nos ILI enquanto o diâmetro menor aumentou 36,36% nos ICI e 66,67% nos ILI. A análise tridimensional revelou que em 76,92% dos ICI e 85,71% dos ILI foi possível a classificação de acordo Vertucci, com maior predominância do tipo I, com canal único, em 46,15% dos ICI e 54,29% dos ILI. Em 15,39% dos ICI e 11,43% de ILI foram identificadas dez novas morfologias. A média do volume (mm3) e da área de superfície (mm2) foram, respectivamente, de 4,38 ± 1,97 e 35,59 ± 11,72 para os ICI e 4,74 ± 1,33 e 38,91 ± 9,56 para os ILI. Os canais acessórios foram observados apenas no terço apical em 46,15% dos ICI e 28,57% dos ILI. Conclui-se que a microtomografia é um método não destrutivo, reprodutível e confiável para estudo de anatomia interna, sendo identificados dez novos tipos morfológicos de SCR de incisivos inferiores. / The knowledge of the root canal system (RCS) is of utmost importance to achieve success in the root canal treatment. The purpose of this study was to evaluate qualitative and quantitatively the RCS anatomy of mandibular incisors by means of microcomputed tomography. The image acquisition of 283 mandibular central incisors (MCI) and 329 mandibular lateral incisors (MLI) was performed using the SkyScan 1174 microtomography device. These images were used to classify the RCS from type I to VIII, considering the number and location of the canals, according to Vertuccis classification. From this sample, thirty-nine MCI and thirty-five MLI were scanned with a resolution of 22.9 μm and reconstructed in order to evaluate the number and location of the main and accessory canals, according to Vertucci\'s classification, the bidimensional parameters of area, roundness, major and minor diameters of the root canal at 1, 2, 3, 4 and 5 mm from the apical foramen, as well as the three-dimensional analysis of volume and surface area. In the apical third, it was found up to three root canals; the area progressively increased from the apical foramen; the roundness ranged from 0.37 ± 0.21 to 0.52 ± 0.19 demonstrating the flat-oval shape of the canals; the major and minor diameters increased 95.45% and 36.36% in the MCI and 135.55% and 66.67% in the MLI, respectively. The threedimensional analysis revealed that in 76.92% of MCI and 85.71% of MLI the RCS could be classified according to Vertucci\'s, and type I (one root canal) was found in 46.15% and 54.29% of MCI and MLI, respectively. Ten new types of root canal morphologies were observed in 15.39% of MCI and 11.43% of MLI. The mean volume (mm3) and surface area (mm2) were 4.38 ± 1.97 and 35.59 ± 11.72 in the MCI, and 4.74 ± 1.33 and 38.91 ± 9.56 in the MLI, respectively. Accessory canals were observed only in the apical third in 46.15% of MCI and 28.57% of MLI. It was concluded that the microtomography is a non-destructive, reproducible and reliable method for the study of the RCS that allowed the identification of ten new types of root canal morphologies in mandibular incisors.
494

Desenvolvimento de um Guia orientativo para dosimetria em Tomografia Computadorizada / Development of a guidance guide for dosimetry in computed tomography

Ladyjane Pereira Fontes 19 October 2016 (has links)
Devido as frequentes dúvidas dos usuários das câmaras de ionização do tipo lápis calibradas no Laboratório de Calibração de Instrumentos do IPEN (LCI IPEN), em como aplicar corretamente os fatores indicados em seus certificados de calibração, foi elaborado um guia orientativo para dosimetria em tomografia computadorizada. O guia orientativo inclui o conhecimento prévio da Camada Semirredutora (CSR), já que é necessário conhecer a energia efetiva do feixe para aplicação do fator de correção para qualidade (kq). A avaliação da CSR em tomógrafos torna-se uma difícil tarefa devido à geometria do sistema e por essa razão foi realizado um levantamento das metodologias existentes para a determinação da CSR em feixes clínicos de Tomografia Computadorizada (TC), levando em consideração fatores técnicos, práticos e econômicos. Neste trabalho, optou-se em testar um Sistema Tandem composto por capas absorvedoras confeccionado na oficina do IPEN, baseado em estudos preliminares devido ao baixo custo e boa reposta. O Sistema Tandem é composto por 5 capas absorvedoras cilíndricas de 1 mm, 3 mm, 5 mm, 7 mm, e 10 mm de alumínio e por 3 capas absorvedoras cilíndricas de 15 mm, 25 mm e 35 mm de acrílico (PMMA) acopladas à câmara de ionização do tipo lápis comercial amplamente utilizada em testes de controle de qualidade na dosimetria em feixes clínicos de Tomografia Computadorizada. Através das curvas Tandem, foi possível avaliar os valores de CSR e, através da curva de calibração da câmara de ionização do tipo lápis, encontrar o Kq adequado ao feixe. O Guia elaborado traz informações de como construir a curva de calibração em função da CSR, para encontrar o Kq, bem como informações para construção da curva Tandem, para encontrar valores próximos de CSR. / Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR.
495

Desenvolvimento e caracterização de câmaras de ionização especiais para feixes de tomografia computadorizada / Development and characterization of special ionization chambers for computed tomography beams

Maysa Costa de Castro 02 May 2016 (has links)
O uso de Tomografia Computadorizada (CT) para procedimentos de imagiologia vem crescendo cada vez mais devido aos avanços da tecnologia dos equipamentos de CT, que permitem a obtenção de imagens com melhor resolução do que por outras técnicas, sendo consequentemente responsável pelo aumento da dose de radiação no paciente durante o procedimento. Isso acarretou uma maior preocupação com as doses recebidas pelos pacientes que se submetem a esse tipo de exame. Para a realização da dosimetria de feixes de CT, o instrumento mais utilizado é a câmara de ionização do tipo lápis, pois este dosímetro apresenta uma resposta uniforme ao feixe de radiação incidente em todos os ângulos. A câmara convencional que se encontra disponível no mercado apresenta um comprimento de volume sensível de 10 cm; entretanto, alguns estudos têm mostrado que esse dosímetro tem subestimado os valores de dose. Portanto, neste trabalho optou-se por desenvolver no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI-IPEN/CNEN) duas câmaras de ionização, fazendo uso de materiais nacionais de baixo custo, com comprimentos de volume sensível de 10 cm e 30 cm. A caracterização destas câmaras foi realizada e os resultados se apresentaram dentro dos limites recomendáveis internacionais. Como uma aplicação, as câmaras desenvolvidas, juntamente com uma câmara comercial, foram testadas em um tomógrafo clínico. As câmaras de ionização desenvolvidas foram analisadas de maneira completa, para os seus possíveis usos. / The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology, because they allow the obtention of images with better resolution than through other techniques. Therefore, they are responsible for increasing the dose radiation of patients during the procedure. This fact led to a greater concern about the doses received by patients who undergo this type of examination. To perform the dosimetry in CT beams, the most widely used instrument is the pencil type ionization chamber, because this dosimeter has a uniform response to the incident radiation beam for all angles. The conventional ionization chamber, which is available on the market, has a sensitive volume length of 10 cm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study two ionization chambers with sensitive volume lengths of 10 cm and 30 cm, making use of low cost national materials, were developed at the Calibration Laboratory of Instruments (LCI-IPEN/CNEN). The characterization of these chambers was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chambers and a commercial chamber were tested in a clinical tomographer. The developed ionization chambers were analyzed in a complete way for their possible uses.
496

Mensuração do volume de perfusão pulmonar obtido por SPECT em uma amostra de pacientes com DPOC, pacientes com distúrbio ventilatório restritivo e voluntários saudáveis

Masiero, Paulo Ricardo January 2009 (has links)
Objetivos Os volumes pulmonares podem ser mensurados através de várias técnicas de imagem, inclusive por SPECT. O objetivo principal deste estudo é comparar o volume de perfusão pulmonar (VPP) mensurado por SPECT perfusional em pacientes com DPOC, pacientes com doença pulmonar restritiva e em voluntários saudáveis. Também pretendemos comparar a técnica de detecção do contorno pulmonar proposta (média+1,5DP) com um algoritmo previamente relatado. Métodos Foram realizados prospectivamente SPECT de perfusão pulmonar, pletismografia de corpo-inteiro e espirometria em pacientes com DPOC (n = 9), pacientes com doença pulmonar restritiva (n = 9) e em voluntários saudáveis (n = 10). A técnica de detecção do contorno pulmonar foi avaliada de forma subjetiva (escore visual) por três examinadores cegados para o método de segmentação. Resultados O VPP foi significativamente diferente entre os grupos. O VPP foi de 3,83 (0,44) litros no grupo com DPOC, 2,33 (0,26) litros nos pacientes com doença pulmonar restritiva e 3,20 (0,73) litros nos voluntários saudáveis (ANOVA, P < 0,001). O volume de perfusão pulmonar (VPP) mostrou correlação com a capacidade residual funcional (r = 0,87, P<0,001), capacidade pulmonar total (r = 0,87, P < 0,001) e volume residual (r = 0,68, P < 0,001). Apesar de não significativo estatisticamente, a técnica média+1,5DP foi melhor na avaliação subjetiva (visual) do que a técnica utilizada previamente. Conclusões O volume de perfusão pulmonar foi capaz de detectar a diferença de volume pulmonar entre os grupos em estudo. Houve correlação com os volumes pulmonares estáticos mensurados pela pletismografia de corpo inteiro. A técnica de segmentação proposta, média+1,5DP, aparenta funcionar melhor do que a técnica de segmentação previamente descrita.
497

TC com muito baixa dose de radia??o, inferior a radiografia panor?mica: protocolo CTdBem para tomografia Multislice dental em pediatria

Haygert, Carlos Jesus Pereira 12 July 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2017-03-10T17:30:42Z No. of bitstreams: 1 TES_CARLOS_JESUS_PEREIRA_HAYGERT_PARCIAL.pdf: 1035016 bytes, checksum: 2e1b1323cdbd59f0bc70829382bd1563 (MD5) / Made available in DSpace on 2017-03-10T17:30:42Z (GMT). No. of bitstreams: 1 TES_CARLOS_JESUS_PEREIRA_HAYGERT_PARCIAL.pdf: 1035016 bytes, checksum: 2e1b1323cdbd59f0bc70829382bd1563 (MD5) Previous issue date: 2016-07-12 / Objective: To compare the total radiation doses obtained in an optimized protocol tomography (MSCT) for hospital use (CTdBem), with the doses obtained in panoramic radiography for dental use, both in pediatric patients and to compare the actual radiation doses to lens, thyroid, salivary glands and gonads obtained from MSCT x panoramic radiograph. Methods: radiation dose data obtained were used in examinations of pediatric patients, and children under 18 years of age treated at the University Hospital of Santa Maria (HUSM), who needed dental evaluation by diagnostic imaging methods. The value of the estimated effective dose of radiation was obtained by computational calculations using the data CTDI (Computed Tomography Dose Index) and DLP (Dose Lenght Product) of MSCT and DAP values (Dose Area Product) for panoramic radiography equipment. The organs were: crystalline, thyroid, salivary glands and gonads, and compared the effective doses of radiation obtained for the different equipment. The radiographic examinations were performed using the pan in equipment X-ray Instrumentarium OP200, 57-85kV, 2-16mAs and acquisition time of approximately 11 seconds. For MSCT was used Toshiba Aquilion64 using 120kV, 10mAs but and acquisition time of approximately 6 seconds. Results: Comparison of DLP CTdBem protocol with panoramic radiograph showed dose values 28,48mSv and 36,45mSv respectively. Comparing the effective doses were found dose values for salivary gland 0,28mSv and 0,36mSv to gonads 2,28mSv and 2,92mSv for thyroid 0,28mSv and 0,36mSv and lens 3, 42mSv and 4,37mSv. Conclusion and Clinical Relevance: The authors conclude that the total doses and also the effective doses of radiation to lens, thyroid, salivary glands and gonads obtained in an optimized protocol of multislice computed tomography for hospital use (CTdBem) doses were lower based on panoramic radiographs. / Objetivo: Comparar as doses totais de radia??o obtidas em um protocolo otimizado de tomografia computadorizada multislice (TCMS) para uso hospitalar (CTdBem), com as doses obtidas em radiografia panor?mica de uso odontol?gico, ambos realizados em pacientes pedi?tricos e comparar as doses efetivas de radia??o para cristalino, tireoide, gl?ndulas salivares e g?nadas obtidas em TCMS x radiografia panor?mica. M?todos: Foram utilizados dados de dose de radia??o obtidos em exames de pacientes pedi?tricos e jovens de at? 18 anos de idade atendidos no Hospital Universit?rio de Santa Maria (HUSM), que necessitavam de avalia??o odontol?gica por m?todos de diagn?stico por imagem. O valor da estimativa da dose efetiva de radia??o foi obtido por calculo computacional utilizando os dados de CTDI (Computed Tomography Dose Index) e DLP (Dose Lenght Product) do TCMS e os valores de DAP (Dose Area Product) para o equipamento de radiografia panor?mica. Foram considerados os ?rg?os: cristalino, tireoide, gl?ndulas salivares e g?nadas, sendo comparadas as doses efetivas de radia??o obtidas para os diferentes equipamentos. Os exames radiogr?ficos foram realizados utilizando a panor?mica em equipamento de raios-X Instrumentarium OP200, 57-85kV, 2-16mAs e tempo de aquisi??o de aproximadamente 11 segundos. Para a TCMS foi utilizado o Toshiba Aquilion64 utilizando 120kV, 10mAs e tempo de aquisi??o de aproximadamente 6 segundos. Resultados: A compara??o da DLP do protocolo CTdBem com radiografia panor?mica mostrou valores de dose de 28,48mSv e 36,45mSv, respectivamente. Quando comparadas as doses efetivas foram encontrados os valores de dose para gl?ndulas salivares de 0,28mSv e 0,36mSv, para g?nadas de 2,28mSv e 2,92mSv, para tireoide de 0,28mSv e 0,36mSv e para cristalino de 3,42mSv e 4,37mSv. Conclus?o e Relev?ncia Cl?nica: Os autores concluem que as doses totais e tamb?m as doses efetivas de radia??o para cristalino, tireoide, gl?ndulas salivares e g?nadas obtidas em um protocolo otimizado de tomografia computadorizada multislice para uso hospitalar (CTdBem) foram inferiores as doses obtidas em radiografias panor?micas.
498

Avaliação da densidade do transportador da dopamina em adolescentes com transtorno de déficit de atenção e hiperatividade

Silva Junior, Neivo da January 2011 (has links)
O Transtorno de Déficit de Atenção/ Hiperatividade (TDAH) é um transtorno comportamental caracterizado por desatenção e/ou hiperatividade, impulsividade causando prejuízo funcional em múltiplos ambientes. Anormalidades no circuito frontoestriatal, o qual é modulado pela dopamina, têm sido relatadas em pacientes com TDAH. Estudos estruturais e funcionais demonstram redução de tamanho e diminuição do fluxo sanguíneo cerebral (FSC) em áreas relacionadas à rede atencional como o lobos frontal, parietal e temporal, estriado e cerebelo. Da mesma forma, a maioria dos estudos que utilizaram radiofármacos seletivos para o transportador da dopamina (DAT), o qual tem um papel importante no metabolismo da dopamina, mostraram maior densidade de DAT estriatal em pacientes com TDAH em comparação com grupo controle. Devido ao fato de algumas pesquisas terem sugerido que anormalidades no fluxo sanguíneo cerebral em estruturas cortico-subcorticais poderiam estar relacionadas a mudanças no sistema dopaminérgico, decidimos investigar a relação entre a densidade do transportador da dopamina no estriado e a perfusão cerebral total. Foi utilizado, para avaliação do DAT, o radiofármaco Tc-99m TRODAT-1 com técnica tomográfica em SPECT e para avaliação da perfusão 99mTc- ECD. Dez adolescentes, diagnosticados com TDAH pelos critérios do DSM-IV, foram avaliados. A análise, através do SPM5, mostrou correlação negativa entre a densidade de DAT no estriado e o fluxo sanguíneo cerebral em cíngulo, frontal, temporal e cerebelo (pFDR<0,01). Buscando entender, um pouco mais, sobre a disponibilidade de DAT e o TDAH, desenvolvemos outra linha de pesquisa que teve como objetivo avaliar a densidade do DAT em indivíduos com TDAH usuários de substâncias psicoativas. O transtorno de uso de substâncias psicoativas (TUSP) é uma comorbidade frequente em adolescentes com TDAH. Crianças com TDAH, acompanhadas durante a transição para a adolescência, demonstram maior uso de drogas psicoativas que o grupo controle com crianças sem TDAH. Embora alguns estudos tenham demonstrado alterações na disponibilidade do DAT em indivíduos com TUSP pouco se sabe sobre a base neurobiológica da comorbidade. Muitas teorias tentam explicar o maior risco de TUSP em pacientes com TDAH. Alguns autores têm sugerido que indivíduos com TDAH fazem uso de drogas, como cocaína e maconha, na tentativa de minimizar os sintomas do TDAH. Indivíduos com TDAH têm disfunções que sugerem o envolvimento do sistema dopaminérgico, principalmente, os núcleos da base e córtex frontal. A literatura tem demonstrado que muitas drogas de abuso afetam tanto o córtex pré-frontal como estruturas subcorticais, apresentando alterações no sistema dopaminérgico. Assim, nós decidimos avaliar a densidade do DAT, utilizando SPECT com 99mTc- TRODAT-1, em adolescentes com TDAH, sem tratamento prévio com metilfenidato, que tinham a comorbidade de uso de substâncias psicoativas (cocaína e maconha) (TDAH+TUSP) e em adolescentes com TDAH sem a comorbidade (TDAH) e comparar com grupo controle sem TDAH e sem TUSP (controle) e grupo apenas com TUSP, sem comorbidade com TDAH (TUSP). Sessenta e dois indivíduos foram avaliados. TDAH (n=11), TDAH+TUSP (n=18), TUSP (n=14) e controle (n=19). A análise semi-quantitativa do potencial de ligação do 99mTc- TRODAT-1 mostrou que o grupo TDAH tinha aumento significativo da densidade de DAT em estriado em comparação aos outros três grupos. O grupo TDAH+TUSP, apesar de mostrar diminuição significativa da densidade de DAT em relação ao grupo TDAH, apresentou maior densidade em relação ao grupo somente TUSP sem que houvesse diferenças significativas em relação ao grupo controle (sem TDAH sem TUSP). Com base nestes achados, poderíamos especular que o uso de maconha e cocaína poderia ser a causa responsável por reduzir a densidade de DAT em indivíduos do grupo TDAH+TUSP e que esses resultados poderiam ajudar a entender a base da teoria de automedicação. / Attention-deficit/hyperactivity disorder (ADHD) is a behavioral disorder characterized by marked symptoms of inattention and hyperactivity, impulsivity causing significant functional impairment in multiple settings (e.g., school and home). Abnormalities of frontostriatal circuits, which are modulated by dopamine, have been found by imaging studies in patients with ADHD. Structural and functional studies have demonstrated reduction in size and decrease in the cerebral blood flow (CBF) in regions related to attentional networks such as frontal lobe, striatum, parietal and temporal lobes and cerebellum. In the same way, studies using special radiolabeled ligands selective of the dopamine transporter (DAT), which has a key function in dopamine metabolism, have showed higher striatal DAT availability in untreated patients with ADHD compared with controls. Due to the fact that some investigations have suggested that CBF abnormalities in cortical-subcortical structures may reflect responses associated with dopaminergic changes, we decided evaluate the relationship between dopamine transporter density in striatum and cortical-subcortical impairment in cerebral blood flow. 99mTc- TRODAT-1 SPECT was used to evaluated DAT density and 99mTc- ECD SPECT to assess brain perfusion. Ten adolescents diagnosed with ADHD according to DSM-IV criteria were investigated. Analysis with SPM5 showed a significant negative correlation between DAT density in the striatum and cerebral blood flow in the cingulate gyrus, frontal lobe, temporal lobe and cerebellum (pFDR<0.01). Seeking to understand more about the availability of DAT and ADHD, we developed another investigation that aimed to evaluate the density of DAT in individuals with ADHD and substance use disorder. Substance use disorder (SUD) is a common comorbidity of ADHD, frequently seen during adolescence. Children with ADHD monitored up to adolescence have significantly greater psychoactive drug use than children without ADHD. Although several studies have shown changes in DAT in these disorders, little is known about the neurobiological basis of the comorbidity. Several theories have been proposed to explain the increased risk for SUD in patients with ADHD. Some authors suggested that patients with ADHD use addictive substances in an attempt to self-medicate the symptoms of the disorder. Children with ADHD have dysfunctions suggesting the involvement of the dopaminergic circuits, mainly in the basal ganglia and frontal cortex. It is well documented that many drugs of abuse affect both prefrontal and subcortical areas resulting in alterations in the dopaminergic system too. Thus, we decided to evaluate striatal DAT density with 99mTc- TRODAT-1 in treatment-naive ADHD adolescents with SUD (ADHD+SUD) and without SUD (ADHD), compared to SUD adolescents without ADHD (SUD) and healthy control subjects (HC). Sixty two male age-matched subjects diagnosed with DSM-IV criteria were included: ADHD (n=11), ADHD+SUD (n=18); SUD (n=14) and HC (n=19). The ADHD group presented significantly higher striatal DAT density compared with ADHD+SUD, SUD and HC groups. Adolescents with ADHD+SUD had significantly lower DAT density than those with ADHD, but significantly higher DAT density than those with SUD only and no significant difference from the healthy control group. Our results might suggest that the use of cannabis and cocaine are responsible for the lower striatal DAT density in the ADHD+SUD compared to the ADHD group which would help to understand the neurobiological basis for the self-medication theory.
499

Estimativa do intervalo postmortem por análise de imagens tomográficas das hipóstases viscerais torácicas / Estimated postmortem interval by analysis of tomographic images of the hypostasis of thoracic organs

Talita Zerbini 26 September 2013 (has links)
Em casos de investigação criminal, a determinação do tempo de morte pode inocentar ou culpar algum suspeito. Atualmente, os estudos publicados relacionados ao advento da autópsia virtual não consideram a possibilidade da utilização dos exames complementares de imagem como auxílio à estimativa do intervalo postmortem, sendo esta uma das principais motivações para a realização do presente estudo, já que a tomografia computadorizada é excelente método de medida de densidade. Diante desse cenário, o objetivo do trabalho foi aprimorar a estimativa do intervalo postmortem por meio da avaliação tomográfica das hipóstases viscerais torácicas. Foi realizado estudo prospectivo observacional com dados obtidos de 23 corpos de pacientes de ambos os sexos que foram encaminhados ao Serviço de Verificação de Óbitos da Capital São Paulo. Foram obtidos cortes tomográficos do segmento torácico de modo sequencial utilizando-se o tomógrafo SOMATOM® Emotion syngo CT 2012E, com intervalo de uma hora entre os exames, a fim de permitir a análise das modificações de densidade das hipóstases ao longo do tempo. Na janela de mediastino, foram selecionados os átrios direito e esquerdo para obtenção das medidas de densidade tecidual média. Foi possível concluir que a maioria das hipóstases pulmonares se estabiliza entre 8 e 12 horas e as hipóstases intracardíacas em torno de 12 horas. Além disso, o modelo estatístico de Mitscherlich pode ser utilizado para descrever o comportamento da hipóstase em função do intervalo de morte decorrido / In cases of criminal investigation, the determination of the time of death can acquit or condemn a suspect. Currently, the published studies related to the raising of the postmortem CT do not consider the possibility of using the complementary image exams as support to the estimate of the postmortem interval, being that one of the main motivations to the execution of the present study, once the multislice computed tomography is an excellent method of measure of density. In this scenery, the goal of this study was to improve the precision of the determination of the time of death through the tomographic evaluation of the visceral thoracic hypostasis. A prospective study was performed with data obtained from 23 bodies of patients, which were forward to the autopsy center of the city of São Paulo. Tomographic images of thorax were obtained sequentially, by using SOMATOM® Emotion syngo CT 2012E, with intervals of one hour each one between the exams, in order to allow the analysis of the modifications of the density of the hypostasis over time. In the mediastinum window, the right and left atrium were selected in order to obtain the measures of the average organ density. It was possible to conclude that the majority of the pulmonary hypostasis would stabilize between 8 and 12 hours and the intracardiac hypostasis around 12 hours. Furthermore, the statistical model of Mitscherlich can be used to describe the behavior of the images according to the postmortem interval
500

Estudo dos tipos de inserção superior do processo uncinado do osso etmoidal por tomografia computadorizada

Netto, Bruno January 2013 (has links)
Objetivo: a inserção superior do processo uncinado (ISPU) é um ponto de referência importante no recesso nasofrontal, mas seu padrão anatômico de distribuição ainda não foi bem estabelecido. O objetivo deste estudo é avaliar os tipos de ISPU por meio da tomografia computadorizada e avaliar a associação entre a drenagem do seio frontal e os tipos de ISPU. Metodologia: estudo transversal retrospectivo realizado no Serviço de Radiologia do Hospital de Clínicas de Porto Alegre (HCPA). Foram analisadas tomografias de seios paranasais de pacientes maiores de 18 anos, sem história de cirurgia nassosinusal, fratura craniofacial, neoplasia maligna ou malformação craniofacial Resultados: foram avaliados 152 exames, totalizando 304 lados analisados. A ISPU foi adequadamente identificada em 292 lados (96%). Foram evidenciados 6 tipos de ISPU: em lâmina papirácea ou célula etmoidal anterior (193; 63,48%); na concha média (19; 6,25%); na base do crânio (19; 6,25%); na lâmina papirácea e na concha média (29; 9,53%); na lâmina papirácea e na base do crânio (29; 9,53%); na base do crânio e na concha média (3; 0,98%). Conclusão: a ISPU apresenta grande variabilidade, mas está em contato direto ou indireto com a lâmina papirácea em 82,5% dos casos. Este padrão anatômico é determinante na drenagem do seio frontal.

Page generated in 0.0754 seconds