• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 422
  • 47
  • 43
  • 35
  • 31
  • 20
  • 18
  • 17
  • 11
  • 9
  • 7
  • 6
  • 5
  • 4
  • Tagged with
  • 1556
  • 1556
  • 670
  • 652
  • 394
  • 393
  • 267
  • 266
  • 257
  • 238
  • 191
  • 180
  • 173
  • 138
  • 137
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Comparações clínicas funcionais e tomográficas entre a doença pulmonar obstrutiva crônica (DPOC) associada ao tabagismo e a DPOC associada à exposição ambiental e/ou ocupacional / Functional and tomographic clinical comparisons between chronic obstructive pulmonary disease (COPD) associated with smoking and COPD associated with environmental and/or occupational exposure

Meneghini, Andréa Cristina 22 November 2018 (has links)
Introdução: A doença pulmonar obstrutiva crônica (DPOC) é caracterizada por limitação ao fluxo aéreo, sendo progressiva e contínua, com diagnóstico baseado na avaliação clínica dos sintomas e espirometria. O tabagismo e a exposição à fumaça de biomassa são alguns dos fatores etiológicos para esta doença. Objetivo: Conhecer as diferenças clínicas, funcionais e tomográficas em voluntários com DPOC por exposição ao tabagismo e por exposição ambiental e/ou ocupacional. Material e Método: É um estudo observacional, transversal e analítico de indivíduos com diagnóstico de DPOC realizado no HCFMRP-USP. Todos os participantes foram submetidos à tomografia computadorizada de alta resolução (TCAR), gasometria arterial, espirometria, mensuração da difusão pulmonar de monóxido de carbono, indução de escarro, coleta de sangue venoso e responderam a um instrumento construído, a escala de dispnéia mMRC, escala de gravidade de DPOC CAT e questionário sócio-demográfico. Foi utilizado o teste exato de Fisher para as variáveis qualitativas e foi realizado para as variáveis quantitativas o teste \"t\" de Student para amostras independentes ou teste não paramétrico de Wilcoxon para amostras independentes. Resultados: Para o estudo, foram incluídos 31 pacientes, 16 pacientes do grupo ambiental e/ ou ocupacional e 15 pacientes do grupo tabagista. Foi observado predomínio do sexo feminino em ambos os grupos. No grupo com DPOC ambiental e/ou ocupacional, foi observada maior média de idade (p = 0,00003); menor grau de instrução (p = 0,02); maior frequência de dispneia (p = 0,015); menor SpO2 no final do teste da caminhada de 6 minutos (p = 0,02), menor pO2 corrigida pela idade e SaO2 (p = 0,02, em ambas as variáveis) e no escarro induzido maior número de células (p = 0,04) e no grupo com DPOC por exposição ao tabagismo foi observado maior ocorrência de enfisema (p < 0,025) e no escarro induzido, maior concentração de IL8 (p = 0,04) e IL6 (p = 0,03). Conclusão: A DPOC ambiental e/ou ocupacional difere da DPOC de etiologia tabagista em relação à gasometria (PaO2 e SaO2), mesmo quando os grupos são semelhantes em gravidade da DPOC e também ocorreu maior frequência de dispneia, mostrando maior acometimento deste grupo. Este grupo apresenta um comportamento de paciente com fenótipo de bronquite crônica e nesta doença a hipoxemia é mais grave e inspira maior atenção por parte da equipe multidisciplinar / Introduction: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation, being progressive and continuous, with a diagnosis based on the clinical evaluation of the symptoms and spirometry. Smoking and exposure to biomass smoke are some of the etiological factors for this disease. Objective: Identify clinical, functional and tomographic differences in volunteers with COPD due to exposure to smoking and environmental and / or occupational exposure. Material and Method: Observational, transversal and analytical study with individuals with COPD diagnosis performed at HCFMRP-USP. All participants underwent high-resolution computed tomography (HRCT), arterial blood gas analysis, spirometry, pulmonary diffusion of carbon monoxide measurement, sputum induction, venous blood collection and responded to a built instrument, mMRC dyspnea scale, severity of COPD CAT and socio-demographic questionnaire. Fisher\'s exact test was used for qualitative variables and Student\'s t-test for independent samples or Wilcoxon\'s non-parametric test for independent samples was performed for the quantitative variables. Results: For the study, 31 patients were included, 16 patients from the environmental and/or occupational group and 15 from the smoking group. Females predominated in both groups. In the group with environmental and/or occupational COPD, a higher mean age (p = 0.00003) was observed; lower level of education (p = 0.02); higher frequency of dyspnea (p = 0.015); lower SpO2 at the end of the 6-minute walk test (p = 0.02), lower age-corrected pO2 and SaO2 (p = 0.02, in both variables) and in sputum induced higher levels of IL8 (p = 0.04), and IL6 (p = 0.03), respectively. The highest incidence of emphysema (p < 0.025) and induced sputum was observed in the group with COPD. Conclusion: Environmental and/or occupational COPD differs from COPD of smoking etiology in relation to arterial blood gas (pO2 and SaO2), even when the groups are similar in severity of COPD, and also a higher frequency of dyspnea occurred, showing a greater involvement of this group. The group presents a behavior of patients with phenotype of chronic bronchitis and in this disease the hypoxemia is more serious and inspires greater attention on the part of the multidisciplinary team
242

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Silva, Fernando Penteado Lopes da 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.
243

Foraminas acessórias mandibulares em tomografia computadorizada de feixe cônico / Accessory mandibular foramina in cone-beam computed tomography

Ikuta, Carla Renata Sanomiya 29 May 2014 (has links)
Com o surgimento da Tomografia Computadorizada de Feixe Cônico (TCFC) foi possível observar estruturas anatômicas que antes não eram visualizadas em radiografias convencionais, como a foramina lingual lateral (FLL). A FLL é um orifício localizado na região posterior lingual da mandíbula que se comunica com o canal mandibular (CM). O objetivo do estudo foi avaliar a presença da FLL em 100 exames de TCFC obtidas pelo aparelho i-CAT Classic®. A presença da FLL foi comparada entre gênero e idade. As FLL foram localizadas em pacientes dentados através de 5 áreas: primeiro pré-molar inferior (A), segundo pré-molar inferior (B), primeiro molar inferior (C), segundo molar inferior (D) e terceiro molar inferior (E). Foram realizadas as medidas de diâmetro axial (DA), diâmetro coronal (DC) e a distância de FLL ao forame mentual (FLL-FM), e FLL à borda inferior da mandíbula (FLL-BI). A FLL estava presente em 39% (39/100) dos exames e foram encontradas 52 FLL (26 exames unilaterais e 13, bilaterais). O lado direito apresentou 29 FLL, enquanto o lado esquerdo 23. A região onde mais foi encontrada FLL foi a região B. 21 foraminas foram encontradas na posição lingual ao FM. O valor médio do DA foi de 1,26±0,57 mm e do DC de 1,82±1,12 mm. Os valores médios da distância de FLLFM e FLL-BI foram 12,74±7,7 e 5,82±2,78 mm, respectivamente. Não houve diferença estatisticamente significante da presença da FLL entre a idade ou o sexo. A medida FLL-FM foi maior em homens tanto do lado direito como do lado esquerdo, mostrando uma diferença estatisticamente significante (p=0,032). / Cone-beam Computed Tomography (CBCT) allowed viewing some anatomical structures that were not noted in bi-dimensional images, such as lateral lingual foramina (LLF). LLF is an aperture located in posterior lingual mandible area, linked with mandibular canal (MC). The present study evaluated the LLF presence through 100 CBCT images, obtained by i-CAT Classic®. Presence or absence of LLF was compared between sex and age. The LLF was located in dentate patients through 5 areas: first lower pre-molar (A), second lower pre-molar (B), first lower molar (C), second lower molar (D) and third lower molar (E). Was measured axial diameter (AD) and coronal diameter (DC), and, the distance from LLF to mentual foramen (LLF-MF) and from LLF to lower mandible border (LLF-LMB). These measures were also compared between gender. LLF was observed in 39% of the exams (39/100). Fiftytwo LLF were found (26 unilateral and 26 bilateral). Right and left sides presented 29 LLF and 23 LLF respectively. The most prevalent area of LLF occurrence was B area. 21 LLF was located in lingual position of MF. The mean average of AD was 1,26±0,57 mm, and CD was 1,82±1,12 mm. The mean average values of LLF-MF and LLF-BI distances were 12,74±7,7 and 5.82±2,78 mm, respectively. There was no statistical difference of gender or age correlated with LLF presence. Men have LLFMF distance greater than woman, showing no statistically significant difference (p=0,032).
244

Estudo da anatomia dental por meio da tomografia computadorizada de feixe-cônico de indivíduos residentes em São Paulo / Study of dental anatomy by cone-beam CT of individuals living in São Paulo

Ferreira, Felipe Potgornik 24 September 2012 (has links)
A grande diversidade existente na cidade de São Paulo Brasil, torna esta cidade um interessante campo para estudos anatômicos em geral. Este estudo teve por objetivo avaliar a morfologia dental interna desta população e suas variações em função do sexo e idade. Foram analisadas 2102 imagens tomográficas obtidas por meio de dois tomógrafos (i-Cat e PreXion) de pacientes que se submeteram ao procedimento diagnóstico por motivos diversos. Todos os grupos dentais foram avaliados individualmente e divididos quanto ao sexo (masculino e feminino) e quanto a idade (18-29, 30-39, 40-49, 50-59, 60-69 e 70-80 anos). O número de raízes foi determinado e a morfologia interna classificada em oito tipos: tipo I (1), tipo II (2-1), tipo III (1-2-1), tipo IV (2), tipo V (1-2), tipo VI (2-1-2), tipo VII (1-2-1-2) e tipo VIII (3), observando-se ainda se a variação anatômica era bilateral. Os resultados foram descritos em tabelas na forma de porcentagem. Pode-se concluir que a anatomia dental interna parece não sofrer influência da idade do indivíduo e pode sofrer influência quanto ao sexo em algumas situações, entretanto a morfologia interna é complexa, sendo que a população da cidade de São Paulo apresenta diferenças anatômicas quando comparada às populações descritas na literatura. / The great diversity in the city of Sao Paulo - Brazil, makes this city an interesting field for anatomical studies. This study aimed to evaluate the internal dental morphology of this population and sex and age variations We analyzed 2102 CT images obtained using two scanners (i-Cat and PreXion) of patients who underwent the diagnostic procedure for several reasons. All dental groups were analized individually and divided by gender (male and female) and by age (18-29, 30-39, 40-49, 50-59, 60-69 and 70-80 years). The number of roots were determined and the internal morphology classified into eight types: type I (1), type II (2-1), type III (1-2-1), type IV (2), type V (1-2), type VI (2-1-2), type VII (1-2-1-2), type VIII (3). Also was observed if anatomical differences was bilateral. The results were reported in the tables as a percentage. The conclusion is that the internal dental anatomy is not influenced by age and can be influenced by sex in some situations, however the internal morphology is complex, and the population of São Paulo presents anatomical differences when compared to populations described in the literature.
245

Monitorização e mensuração tomográfica de diferentes técnicas de crioterapia em pele de cães da raça Beagle, e sua relação com as medidas da necrose estimadas pela histopatologia / Computed tomography monitoring and mensuration of different cryotherapy techniques on the skin of Beagle dogs and their association with necrosis assessment through histopathological analysis

Lucas, Ronaldo 18 November 2004 (has links)
O uso do frio pela medicina é muito antigo, utilizado inicialmente de forma empírica, teve grandes avanços nos séculos XIV e XX, evoluindo juntamente com a Física. O surgimento de novas técnicas e equipamentos, possibilitou à crioterapia tornar-se uma importante opção no tratamento de neoplasias, benignas e malignas, de diferentes órgãos (tais como fígado, próstata, pâncreas e mamas) e sistemas (ósseo, neurológico e tegumentar). O grande desenvolvimento tecnológico permitiu além do maior número de indicações, melhores resultados, mormente com o uso de técnicas de imagem para o acompanhamento do procedimento. Porém, poucos são os trabalhos que enfocam a monitorização e mensuração do congelamento, pela tomografia computadorizada, bem como avaliação da necrose obtida. No presente trabalho propôs-se avaliar as relações entre as medidas obtidas pela tomografia computadorizada, em 20 cães da raça Beagle, durante o congelamento por aplicação do nitrogênio pela sonda fechada (75 segundos), spray (75 e 135 segundos) e derramamento (75 segundos), comparando estas medidas com aquelas mensuradas pela histopatologia da necrose provocada, para posteriormente avaliar a efetividade dos métodos e criar protocolos de tratamento. Os valores de diâmetro, raio, profundidade e volume do congelamento foram comparados entre si e, com os respectivos valores da necrose após 96 horas do procedimento. Os valores foram submetidos a análise de variância de medidas repetidas e teste de Bonferroni (p<0,05). Constatou-se que: a técnica de sonda fechada oferece congelamento e subseqüente necrose mais superficial que os outros métodos, sendo a técnica menos efetiva; em todas as técnicas o volume, diâmetro e profundidade são inferiores no tecido necrosado quando comparados aos seus similares naquele congelado; em nenhuma das quatro técnicas a profundidade de congelamento foi equivalente ao seu raio. Finalmente, houve a possibilidade de desenvolvimento de protocolos alternativos de congelamento a partir da profundidade de necrose pretendida (hf), obtendo-se como resultado (sonda - Di = hf / 0,29; spray I; Di = hf / 0,31; spray II - Di = hf / 0,35; derramamento -Di = hf / 0,38) o diâmetro do congelamento (Di) necessário para o êxito do tratamento / The use of cold by Medicine is a very old practice, initially used empirically, which had significant advances in the XIV and XX centuries, developing along with Physics. The appearance of new techniques and equipment turned cryotherapy into an important option in the treatment of benign and malignant neoplasms in different organs (such as the liver, the prostate, the pancreas and breasts) and systems (bone, neurological and tegumentary). The large technological development resulted in a higher number of indications as well as better results, especially with the concomitant use of imaging techniques to follow the procedure. However, few studies focus on the monitoring and mensuration of freezing through computed tomography, as well as the assessment of the resulting necrosis. Our study aims at evaluating the association between the measurements obtained through computed tomography in 20 Beagle dogs during freezing by liquid nitrogen use through a probe (75 sec), spray (75 and 135 sec) and overflow (75 sec), comparing these measurements to those obtained through histopathological analysis of the resulting necrosis, for later evaluation of the effectiveness of the methods and design of better treatment protocols. The values of diameter, radius, depth and volume of freezing were compared among them and also with the respective necrosis values 96 hours after the procedure. The values were submitted to analysis of variance of repeated measurements and Bonferroni test (p<0.05). We observed that the closed probe technique causes a more superficial freezing and resulting necrosis when compared to the other methods, being the less effective technique. In all techniques, the volume, diameter and depth are lower in the necrotic tissue when compared to those in the frozen tissue; none of the four techniques showed that freezing depth was equivalent to its radius. Finally, alternative freezing protocols could be developed from the depth of the intended necrosis (hf), resulting in the freezing diameter (Di) (probe - Di = hf/0.29; spray I; Di = hf/0.31; spray II Di = hf/0.35; overflow Di = hf/0.38), which is necessary for therapy success
246

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
247

Avaliação de realce tardio pela Tomografia Computadorizada em pacientes chagásicos crônicos com disfunção ventricular / Delayed enhanced computed tomography in chronic chagasic patients with ventricular dysfunction

Silva, Nackle Jibran 26 June 2014 (has links)
A Doença de Chagas é uma infecção parasitária causada pelo Trypanosoma cruzi1, transmitida aos humanos principalmente pelas fezes contaminadas de insetos triatomídio. Esta patologia permanece endêmica na América Latina com grande impacto socioeconômico. O envolvimento cardíaco é a principal causa de morte, sendo que a fisiopatologia e a evolução clínica da doença não são completamente compreendidas e a estratificação de risco permanece desafiadora. A presença de disfunção miocárdica associada ou não à doença arterial aterosclerótica vem acompanhada de áreas de fibrose miocárdica e tem se mostrado como importante fator de pior prognóstico. Ressonância Magnética (RM) é um método já consagrado na detecção de fibrose miocárdica pela técnica de realce tardio (RT). Os objetivos deste trabalho foram: identificar e quantificar a área de realce tardio em pacientes com Cardiopatia Chagásica e disfunção contrátil do ventrículo esquerdo por meio da Tomografia Coronária; associar a extensão do RT pela tomografia com a FE do ventrículo esquerdo, medida pela ecocardiografia; determinar se há ou não associação da presença e extensão do realce tardio com a presença de coronariopatia significativa; determinar a presença de aterosclerose coronária neste subgrupo de pacientes chagásicos por meio do escore de cálcio; e identificar a presença de coronariopatia obstrutiva nesta população. Foram selecionados 36 pacientes com o diagnóstico confirmado de Doença de Chagas e disfunção ventricular (FE< 50%) confirmada pela ecocardiografia que respeitaram os critérios de inclusão e exclusão, e que assinaram o termo de consentimento livre e esclarecido. Todos os pacientes foram submetidos a angiotomografia coronária com a técnica de realce tardio e escore de cálcio. Todos os pacientes completaram o protocolo sem efeitos adversos com dose de radiação média de 11,17 +- 1,26 mSv e com exames interpretáveis. Observadores cegos e independentes, sem conhecimento prévio dos dados clínicos ou dos exames, realizaram análise visual e quantitativa do grau de estenose coronária, do escore de cálcio e do realce tardio. A média da idade foi de 57,5+- 8, dos quais 61,1% eram mulheres. A média da FE foi de 38,19 +- 6,91. Foram encontradas 2 lesões significativas (>50%) em 2 pacientes. A média do escore de cálcio foi de 19,06 +- 40,72. A fibrose miocárdica foi observada em 86,1% dos 36 pacientes e sua quantificação foi realizada de acordo com o esquema de segmentação miocárdica segundo a orientação da American Hear Association. A partir dos nossos achados, concluímos que, por meio da Tomografia coronária, é possível identificar áreas de fibrose miocárdica em pacientes chagásicos, que a quantidade de fibrose é inversamente proporcional à fração de ejeção ventricular esquerda (r= 0,52 p = 0,0011) e que a fibrose segue um padrão de localização específico da doença. Nossos achados permitem também inferir que a fibrose miocárdica nesse grupo de pacientes não se correlaciona à presença de obstruções coronárias, sendo o padrão de realce tardio diferente daquele observado em portadores de doença arterial coronária. Não houve correlação entre o escore de cálcio e áreas de fibrose vistas pela técnica de realce tardio (r= 0,04 p= 0,80). Desta forma, a tomografia pode ser uma alternativa à RM para a pesquisa de fibrose em pacientes chagásicos, aspecto que pode ser particularmente relevante naqueles que apresentam contraindicação formal à realização deste exame. / Chagas disease is a parasitic infection caused by Trypanosoma cruzi1. It is transmitted to humans mainly by the infected feces of triatomine insects. This pathological condition remains endemic in Latin America, posing a major socioeconomic impact on the region. Cardiac involvement is the principal cause of death of patients, given that the physiopathological mechanism and clinical evolution of the disease are not fully understood and risk stratification remains a challenge. Whether associated with arteriosclerotic vascular disease or not, the presence of myocardial dysfunction is accompanied by areas of myocardial fibrosis and has emerged as an important factor associated with poor prognosis. Magnetic resonance (MR) imaging is a well-established method of detecting myocardial fibrosis by the delayed enhancement (DE) technique. Objectives: The objectives of this thesis are to identify and quantify DE areas on left ventricular contractile dysfunction patients with chagasic cardiopathy using coronary tomography, to associate tomography DE extension with left ventricular ejection fraction (EF) measured by echocardiography, to determine whether the presence and extension of DE are associated with the presence of significant coronaropathy, and to identify the presence of obstructive coronaropathy in chagasic patients. Background: Methods: Thirty six patients with confirmed Chagas disease and ventricular dysfunction diagnosis (EF < 50%), as verified by echocardiography. All the patients underwent coronary computed tomographic (CT) angiography using DE technic. All the patients successfully completed the protocol with a mean radiation dose of 11.17 1.26 mSv, without adverse effects and undergoing measurable tests. Independent observers blinded to the clinical data or examinations of the patients performed visual and quantitative analyses of the degree of coronary stenosis, and DE. Results: The mean age was 57.5 8 years, and 61.1% of them were female. The mean EF was 38.19 6.91%. Two significant lesions (>50%) were identified in two patients. Myocardial fibrosis was observed in 86.1% of the 36 patients, and its quantification was assessed in accordance with the myocardial segmentation scheme and the American Heart Association guidelines The amount of fibrosis is inversely proportional to left ventricular EF (r = 0.52, p = 0.0011), and that the myocardial fibrosis in these patients follows the specific localization pattern of Chagas disease. Our findings reveal that myocardial fibrosis in this patient sub group was not related to coronary obstruction and that the DE pattern is different from the one found in patients who presented ischemic events. Computed tomography DE is also inversely related to left ventricle ejection fraction, another important prognosis marker. Therefore, computed tomography can provide an adequate alternative to MR in the assessment of myocardial fibrosis particularly in patients presenting formal contraindications to MR.
248

Desenvolvimento de um Guia orientativo para dosimetria em Tomografia Computadorizada / Development of a guidance guide for dosimetry in computed tomography

Fontes, Ladyjane Pereira 19 October 2016 (has links)
Devido as frequentes dúvidas dos usuários das câmaras de ionização do tipo lápis calibradas no Laboratório de Calibração de Instrumentos do IPEN (LCI IPEN), em como aplicar corretamente os fatores indicados em seus certificados de calibração, foi elaborado um guia orientativo para dosimetria em tomografia computadorizada. O guia orientativo inclui o conhecimento prévio da Camada Semirredutora (CSR), já que é necessário conhecer a energia efetiva do feixe para aplicação do fator de correção para qualidade (kq). A avaliação da CSR em tomógrafos torna-se uma difícil tarefa devido à geometria do sistema e por essa razão foi realizado um levantamento das metodologias existentes para a determinação da CSR em feixes clínicos de Tomografia Computadorizada (TC), levando em consideração fatores técnicos, práticos e econômicos. Neste trabalho, optou-se em testar um Sistema Tandem composto por capas absorvedoras confeccionado na oficina do IPEN, baseado em estudos preliminares devido ao baixo custo e boa reposta. O Sistema Tandem é composto por 5 capas absorvedoras cilíndricas de 1 mm, 3 mm, 5 mm, 7 mm, e 10 mm de alumínio e por 3 capas absorvedoras cilíndricas de 15 mm, 25 mm e 35 mm de acrílico (PMMA) acopladas à câmara de ionização do tipo lápis comercial amplamente utilizada em testes de controle de qualidade na dosimetria em feixes clínicos de Tomografia Computadorizada. Através das curvas Tandem, foi possível avaliar os valores de CSR e, através da curva de calibração da câmara de ionização do tipo lápis, encontrar o Kq adequado ao feixe. O Guia elaborado traz informações de como construir a curva de calibração em função da CSR, para encontrar o Kq, bem como informações para construção da curva Tandem, para encontrar valores próximos de CSR. / Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR.
249

Estudo dos canais alveolares superiores e do canal infra-orbital por meio da tomografia computadorizada de feixe cônico / Study of the superior alveolar canals and infraorbital canal using cone beam computed tomography

Nicolielo, Laura Ferreira Pinheiro 23 August 2013 (has links)
Para oferecer mais informações aos cirurgiões no planejamento de intervenções cirúrgicas maxilofaciais, o presente estudo teve como objetivo avaliar a presença, localização e tamanho dos canais alveolares superiores (CAS), anterior (CASA) e posterior (CASP), canal infra-orbital (CI) e forame infra-orbital (FI) em imagens de tomografia computadorizada de feixe cônico (TCFC) de 100 pacientes adultos (&#x2265; 20 anos), obtidas pelo aparelho i-CAT Classic®. Um examinador calibrado observou a presença dos CAS, CI e FI bilateralmente. Quando presentes, eram medidos comprimento (parte descendente, parte do assoalho da órbita e total), largura e altura do CI; altura, largura e distância ao rebordo inferior da órbita (RIO) do FI; distância da borda inferior dos CAS a crista do rebordo alveolar em 5 regiões: canino (CAN), primeiro pré-molar (1PM), segundo pré-molar (2PM), primeiro molar (1M) e segundo molar (2M); e os diâmetros dos CAS. Foram também observados a localização dos CAS em relação ao seio maxilar e a presença de reparos anatômicos como canal duplo/múltiplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme. Associações entre homens e mulheres, lados direito e esquerdo e regiões foram investigadas para todas as medidas e visibilidade, utilizando separadamente os métodos estatísticos. A presença do CI e FI foi de 100%. A visibilidade do CASA/CASP foi de: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). As médias dos comprimentos da parte descendente, da parte do assoalho da órbita e total do CI foram de 8,82mm, 19,44mm e 28,35mm, respectivamente. Altura e largura médias do CI foram, respectivamente, 2,08mm e 3,91mm. As médias da altura, largura e distância ao RIO do FI foram: 4,43mm, 5,18mm e 7,52mm, respectivamente. As distâncias médias do CASA ao rebordo alveolar foram: 18,54mm (CAN), 25,47mm (1PM), 28,43mm (2PM), 30,78mm (1M) e 33,21mm (2M); e do CASP: 22,3mm (1PM), 17,65mm (2PM), 15,34mm (1M) e 16,87mm (2M). As médias dos diâmetros do CASA e do CASP foram 0,90mm e 0,83mm, respectivamente, sendo que 77,5% dos CASA e 82% dos CASP eram &#x2264; 1mm e 22,5% dos CASA e 18% dos CASP eram entre 1-2 mm. Em relação ao seio maxilar, 53% e 44% dos CASA foram encontrados no terço superior e médio, respectivamente, e 64% e 36% dos CASP foram encontrados no terço inferior e médio, respectivamente. Houve diferença estatisticamente significativa (p<0,05) entre homens e mulheres para o comprimento, altura e largura do CI; para a altura, largura e distância ao RIO do FI; e para as distâncias dos CAS ao rebordo alveolar. CASA duplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme foram detectados em 24,5%, 38,5% e 84% dos casos, respectivamente. A localização da anastomose foi teve maior ocorrência entre o CAN e 1PM (43%). Os resultados sugerem que a TCFC seja uma ferramenta adequada para examinar os CAS, CI e FI no planejamento de procedimentos cirúrgicos do terço médio da face, a fim de evitar danos a estruturas neurovasculares importantes. / To provide more information to clinicians in planning maxillofacial surgical interventions, the present study evaluated the presence, location and size of the superior alveolar canals (SAC), anterior (ASAC) and posterior (PSAC), infraorbital canal (IC) and infra-orbital foramen (IF) in cone beam computed tomography (CBCT) of 100 adult patients (&#x2265; 20 years old), obtained by i-CAT Classic®. One calibrated examiner observed SAC, IC and IF presence, bilaterally. When present, were measured: length (descending part, orbital floor part and total), width and height of the IC, height, width and distance from the IF to the inferior orbital rim (IOR), distance from the lower border of SAC to the alveolar crest in 5 regions: canine (CAN), first premolar (1PM), second premolar (2PM), first molar (1M) and second molar (2M); and the diameters of SAC. It was also observed the location of SAC in relation to the maxillary sinus floor and the presence of anatomical landmarks such as doble/multiple canal, intraosseous anastomosis and ASAC extension to the piriform aperture. Associations between men and women, right and left sides and regions were investigated for all measurements and presence using statistical methods separately. The presence of the IC and IF was 100%. The presence of ASAC/PSAC was: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). The mean lengths of the IC descending part, IC orbital floor part and total lenght of the IC were 8.82mm, 19.44mm and 28.35mm, respectively. The mean height and width of the IC were, respectively, 2.08mm and 3.91mm. The mean height, width and distance to the IOR of IF were: 4.43mm, 5.18mm and 7.52mm, respectively. The mean distances of ASAC to the alveolar crest were: 18.54mm (CAN), 25.47mm (1PM), 28.43mm (2PM), 30.78mm (1M) and 33.21mm (2M); and of PSAC: 22.3mm (1PM), 17.65mm (2PM) 15.34mm (1M) and 16.87mm (2M). The mean diameters of ASAC and PSAC were 0.90mm and 0.83mm, respectively, and that, 77.5% of ASAC and 82% of PSAC were &#x2264; 1mm and 22.5% of ASAC and 18% of PSAC were between 1-2 mm. In relation to the maxillary sinus, 53% e 44% of the ASAC were found in the upper and middle third of maxillary sinuses, respectively, and 64% and 36% of the PSAC were found in lower and middle third, respectively. There was a statistically significant difference (p<0.05) between men and women for the length, height and width of the IC, for the height, width and distance to the IOR of IF, and for distances of SAC to the alveolar crest. Double ASAC, intraosseous anastomosis and ASAC extension to the piriform aperture were present in: 24.5%, 38.5% and 84% of the cases, respectively. The location of the anastomosis had more incidence between the CAN and 1PM (43%). The results suggest that CBCT is a suitable tool to evaluate the SAC, IC and IF, assisting surgeons in planning surgical procedures of the midface, in order to avoid damage to important neurovascular structures.
250

Análise quantitativa automática da vasculatura pulmonar em TCAR de pacientes com hipertensão pulmonar / Automatic quantitative analysis of pulmonary vasculature on HRCT of patients with pulmonary hypertension

Melges, Gustavo Cabrera 01 June 2017 (has links)
A hipertensão pulmonar (HP) é uma doença caracterizada por elevação da pressão da artéria pulmonar e um aumento da resistência vascular pulmonar levando à disfunção do ventrículo direito, sendo complicação importante de doenças como a doença pulmonar obstrutiva crônica (DPOC), doença pulmonar intersticial (DPI), colagenoses e vasculites. A tomografia computadoriza de alta resolução (TCAR) é um dos principais métodos de diagnóstico e acompanhamento destas doenças. Neste estudo objetivamos a analise quantitativa dos exames de TCAR do tórax em pacientes com doenças parenquimatosas difusas e hipertensão pulmonar diagnosticada por cateterismo direito. Foram analisados retrospectivamente os prontuários eletrônicos e os exames de TCAR de 29 pacientes com HP, em comparação com um grupo controle. Foram excluídos os casos de hipertensão arterial pulmonar primária e tromboembolismo crônico, cuja investigação é feita prioritariamente com exame de angiotomografia. A análise quantitativa foi realizada utilizando programa completamente automático e algumas medidas manuais também foram realizadas. O pacientes com HP, quando comparados ao controle, apresentaram redução do volume pulmonar, aumento da atenuação média do parênquima, aumento na medida do volume vascular pulmonar, aumento da densidade vascular pulmonar e na relação do volume vascular nos lobos superiores em relação aos lobos inferiores. O programa automático foi capaz de identificar as alterações da vasculatura, mesmo em se tratando de exames não contrastados e em meio a alterações arquiteturais do parênquima pulmonar. Estes achados provavelmente representam a redistribuição da trama vascular pulmonar, relacionada ao aumento da resistência vascular pulmonar. A análise quantitativa automática, realizada em exames de TCAR já utilizados na rotina clínica, pode representar nova ferramenta não invasiva capaz de identificar sinais de HP em pacientes com fator de risco, como DPOC, DPI, colagenoses, em que a HP representa complicação importante e de diagnóstico muitas vezes difícil / Pulmonary hypertension (PH) is a disease characterized by elevation in the mean pressure of the pulmonary artery and an increase in the pulmonary vascular resistance leading to right heart dysfunction, being an important complication of multiple diseases such as chronic obstructive pulmonary disease (COPD), interstitial lung disease (ILD), collagen diseases and vasculitis. The high resolution computed tomography (HRCT) is one of the main diagnostic methods and is also important in the follow up of these patients. In this study we aim the quantitative analysis of the thoracic HRCT exams in patients with diffuse parenchymal lung disease and pulmonary hypertension diagnosed by right heart catheterism. We analised retrospectively the clinical records and HRCT exams of 29 patients with PH, comparing to a control group. Were excluded from the study patients with primary pulmonary arterial hypertension (PAH) and chronic thromboembolism pulmonary hypertension (CTEPH), which investigations usually include pulmonary angiotomography. The quantitative analysis was made utilizing a completely automatic software and some manual measures were also noted. Patients with PH, when comparing to control group, presented significant pulmonary volume reduction, elevated mean parenchymal attenuation, elevated measures of the pulmonary vascular volume, increase in the pulmonary vascular density and also an elevation in the relation between vascular volume in the upper pulmonary lobes and the lower lobes. The automatic software was able to identify the vascular alterations, even in non contrast enhanced exams and amidst architectural distortions in the lung parenchyma. These findings probably represent the redistribution of the pulmonary vascular bed, related to the pulmonary vascular resistance increase. .The quantitative automatic analysis, made in HRCT exams, used in clinical practice, can represent a new non invasive tool, able to identify PH signs in risc patients, such as COPD, ILD and collagen diseases, in which PH represents an important complication with, many times, difficult diagnosis.

Page generated in 0.0882 seconds