Desenvolvimento de uma nova versão do injetor comutador automático: determinação fotométrica de etanol em bebidas destiladas / Development of a new version of the automatic injector commutator: photometric determination of ethanol in spirits

Santos Junior, Felisberto Gonçalves 12 September 2012 (has links)
Neste trabalho, apresentamos uma nova versão do injetor comutador, baseada na geometria retangular, mantendo a configuração de três peças, sendo a central móvel e as laterais fixas. Nesta condição, os parafusos de ajuste não funcionam como guia, tal como ocorre nos injetores da primeira geração. Este design facilita o deslocamento da parte móvel, contribuindo para a redução do atrito, o que permite o emprego de um pequeno motor de corrente contínua (12 V; 0,4 A), o qual foi usado para fazer o deslocamento da barra central da posição de amostragem para a de injeção e vice-versa. O funcionamento do injetor foi controlado pelo computador, usando apenas 2 bits de controle. A interface de controle projetada para esse fim, inclui a condição de reversão da direção de rotação do motor e lógica anti-duplicidade, então se os dois bits forem ativados ao mesmo tempo, a rotação do motor é mantida no sentido horário. Para testar a viabilidade deste injetor, o mesmo foi empregado para desenvolver um procedimento para determinação de etanol em bebidas destiladas. O procedimento fotométrico foi baseado na reação de etanol com dicromato de potássio. A detecção fotométrica foi realizada empregando um fotômetro de LED com máximo de emissão em 590 nm. O módulo de análise constituído pelo injetor e um conjunto de válvulas solenoide foi projetado para implementar o processo de reamostragem, adição intermitente de reagentes e transporte da zona de amostra com fluxo de ar. Após a definição das variáveis de controle, o sistema apresentou bom desempenho analítico, aliando vantagens tais como, boa velocidade, simplicidade de operação, versatilidade, proporcionando também um menor consumo de amostra e reagentes. Com relação às características analíticas, o sistema proposto apresentou faixa de resposta linear (r = 0,9972) para concentração etanol entre 10 - 50 % (v/v), limite de detecção de 2,0 % (v/v) etanol, desvio padrão relativo de 2,0 % (n =10) para uma amostra de etanol com concentração 40 % (v/v), um consumo de dicromato de 0,012 g por determinação e uma frequência analítica de 34 determinações por hora. / We present a new version of the commutator injector, based on the rectangular geometry, maintaining the three parts configuration with the central mobile and fixed side. In this condition, the adjusting screws do not functi as a guide, as occurs in the injector of first generation. This design facilitates the displacement of the movable part and contributes in reducing the friction, thus allowing the use of a small direct current motor (12 V, 0.4 A), which was used to perform the displacement of the central bar from the sampling position to the injection and vice-versa. The injector operation was controlled by a computer, which was done using only two control bits. The control interface designed for this purpose includes the condition for reversing the direction of the motor rotation and anti-duplication logic, so that both bits were activated at the same time, the motor rotation was maintained at clockwise direction. To test the feasibility of the injector, it was used to develop a procedure for determination of ethanol in spirit beverage. The procedure was based on the photometric reaction of ethanol with potassium dichromate. The photometric detection was performed using a LED based photometer with maximum of emission at 590 nm. The analytical module comprising the injector and a set of solenoid valves, was designed to implement the zone sampling process and Intermittent addition of reagents and sample zone displacement using an air stream. After definition of control variables, the system shown good analytical performance, combining advantages such as speed, simplicity of operation, versatility and also providing lower consumption of sample and reagents. With respect to analytical characteristics, the proposed system presented linear response range (r = 0.9972) between ethanol concentration to 10 - 50% (v/v), a detection limit of 2.0% (v/v) ethanol, relative standard deviation of 2.0% (n = 10) for a sample with an ethanol concentration of 40% (w/v), a dichromate consumption of 0.012 g by determination and a sampling rate of 34 determination per hour.
2

Desenvolvimento de uma nova versão do injetor comutador automático: determinação fotométrica de etanol em bebidas destiladas / Development of a new version of the automatic injector commutator: photometric determination of ethanol in spirits

Felisberto Gonçalves Santos Junior 12 September 2012 (has links)
Neste trabalho, apresentamos uma nova versão do injetor comutador, baseada na geometria retangular, mantendo a configuração de três peças, sendo a central móvel e as laterais fixas. Nesta condição, os parafusos de ajuste não funcionam como guia, tal como ocorre nos injetores da primeira geração. Este design facilita o deslocamento da parte móvel, contribuindo para a redução do atrito, o que permite o emprego de um pequeno motor de corrente contínua (12 V; 0,4 A), o qual foi usado para fazer o deslocamento da barra central da posição de amostragem para a de injeção e vice-versa. O funcionamento do injetor foi controlado pelo computador, usando apenas 2 bits de controle. A interface de controle projetada para esse fim, inclui a condição de reversão da direção de rotação do motor e lógica anti-duplicidade, então se os dois bits forem ativados ao mesmo tempo, a rotação do motor é mantida no sentido horário. Para testar a viabilidade deste injetor, o mesmo foi empregado para desenvolver um procedimento para determinação de etanol em bebidas destiladas. O procedimento fotométrico foi baseado na reação de etanol com dicromato de potássio. A detecção fotométrica foi realizada empregando um fotômetro de LED com máximo de emissão em 590 nm. O módulo de análise constituído pelo injetor e um conjunto de válvulas solenoide foi projetado para implementar o processo de reamostragem, adição intermitente de reagentes e transporte da zona de amostra com fluxo de ar. Após a definição das variáveis de controle, o sistema apresentou bom desempenho analítico, aliando vantagens tais como, boa velocidade, simplicidade de operação, versatilidade, proporcionando também um menor consumo de amostra e reagentes. Com relação às características analíticas, o sistema proposto apresentou faixa de resposta linear (r = 0,9972) para concentração etanol entre 10 - 50 % (v/v), limite de detecção de 2,0 % (v/v) etanol, desvio padrão relativo de 2,0 % (n =10) para uma amostra de etanol com concentração 40 % (v/v), um consumo de dicromato de 0,012 g por determinação e uma frequência analítica de 34 determinações por hora. / We present a new version of the commutator injector, based on the rectangular geometry, maintaining the three parts configuration with the central mobile and fixed side. In this condition, the adjusting screws do not functi as a guide, as occurs in the injector of first generation. This design facilitates the displacement of the movable part and contributes in reducing the friction, thus allowing the use of a small direct current motor (12 V, 0.4 A), which was used to perform the displacement of the central bar from the sampling position to the injection and vice-versa. The injector operation was controlled by a computer, which was done using only two control bits. The control interface designed for this purpose includes the condition for reversing the direction of the motor rotation and anti-duplication logic, so that both bits were activated at the same time, the motor rotation was maintained at clockwise direction. To test the feasibility of the injector, it was used to develop a procedure for determination of ethanol in spirit beverage. The procedure was based on the photometric reaction of ethanol with potassium dichromate. The photometric detection was performed using a LED based photometer with maximum of emission at 590 nm. The analytical module comprising the injector and a set of solenoid valves, was designed to implement the zone sampling process and Intermittent addition of reagents and sample zone displacement using an air stream. After definition of control variables, the system shown good analytical performance, combining advantages such as speed, simplicity of operation, versatility and also providing lower consumption of sample and reagents. With respect to analytical characteristics, the proposed system presented linear response range (r = 0.9972) between ethanol concentration to 10 - 50% (v/v), a detection limit of 2.0% (v/v) ethanol, relative standard deviation of 2.0% (n = 10) for a sample with an ethanol concentration of 40% (w/v), a dichromate consumption of 0.012 g by determination and a sampling rate of 34 determination per hour.
3

Modelo de produto como integrador em sistemas de manufatura

Barra, Rogerio Almeida 26 September 1989 (has links)
Orientador: Manuel de Jesus Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T03:17:23Z (GMT). No. of bitstreams: 1 Barra_RogerioAlmeida_M.pdf: 12570817 bytes, checksum: 6f017482856bcb42a5bd4d46c88f700e (MD5) Previous issue date: 1989 / Resumo:Os sistemas de manufatura da década de noventa se caracterizarão por uma utilização maciça de computadores. Visando a automação das tarefas envolvidas no ciclo de projeto e manufatura de produtos. Neste sentido, as empresas têm feito grandes investimentos em sistemas CAD. CAN. m.á.quinas CNC. Robôs, etc. O conceito de Manufatura Integrada por Computador-CIM surge da necessidade de que estes sistemas cooperem entre si. a fim de que a empresa opere em um nível máximo d. eficiênc1a. Para isto. Deve ser possível transferir entre sistemas. Dados que tenham um significado comum a eles. de t.al forma que possam ser utilizados pelo sistema que os recebe. Uma parte significativa destes dados a serem trocados diz raspei t.o a. produtos. Neste contexto este trabalho tem por objetivos definir que requisitos um modelo de produto deve satisfazer a fim de prover às aplicações em um sistema CIM todas as informações que elas necessitem verificar os esforços de padronização deste modelo e a relevância destes no que diz respeito à implantação de um sistema que possibilite um efetivo compartilhamento de 1nformações sobre produtos entre seus componentes. Como resultado final é proposta uma arqu1tetura para este sistema / Abstract: Manufacturing systems of the nineties will be distinguished by massive computer use, aiming at automation of tasks along the product design and manufacturing cycle. Thus, companies have invested heavily on CAD/CAM systems, CNC machines, robots, etc. The concept of Computer Integrated Manufacturing-CIM arises from the necessity that these systems cooperate, so that the company operates at a maximum efficiency level. For this, it must be possible transfer, among these systems, data that have a meaning common to them, so that they can be used by the system receiving them. Significant part of the data to be exchanged relates to products. In this context this work intends to define which requirements a product model must. Satisfy in order to provide to applications within a CIM system alI 1nf'ormation they need, verify the efforts to standardize this model and their relevance concerning the implementation of' a system that enables an effective product information sharing among its components. As a final result_ architecture for this system is proposed. / Mestrado / Mestre em Ciências
4

Sistema inteligente para controle de relés reguladores de tensão / Intelligent system to control voltage regulator relays

Spatti, Danilo Hernane 26 February 2007 (has links)
Este trabalho apresenta uma estratégia para realizar o controle de tensão em um sistema de distribuição de energia elétrica dotado de comutadores de tap sob carga. Será investigada a aplicação de sistemas inteligentes para tornar os relés reguladores de tensão mais flexíveis. A inserção de módulos inteligentes em relés reguladores de tensão convencionais irá permitir um melhor aproveitamento das funcionalidades já existentes destes dispositivos. Ainda como foco do estudo, pretende-se atuar apenas na subestação de distribuição, realizando medições no barramento secundário e tomando medidas de controle também neste barramento. A capacidade dos sistemas fuzzy em tratar informações incertas, bem como sua potencial aplicabilidade em problemas tendo comportamentos não previsíveis, permitiram a criação de uma estratégia de controle de tensão que atende todas as regulamentações dos órgãos fiscalizadores e, também, os anseios das concessionárias de distribuição de energia elétrica devido aos resultados promissores obtidos em simulação com dados reais das subestações. / This work presents an approach to voltage control in power distribution systems with load tap changers. Intelligent approaches are studied and applied in voltage regulator relay in order to improve the voltage profiles of the system. The proposal of this work is the addition of fuzzy modules in the conventional voltage regulator relays, which allows the exploration of the main functionalities already implemented in such devices. The adaptive fuzzy voltage regulator relay controls the voltage in the distribution substation, monitoring electrical variables and performing the regulation on secondary bus based on the results provided by the fuzzy modules, which are capable to take into account the voltage profile standards for distribution systems as well as operational interests defined by electrical distribution companies. Simulation results using real data from substations are presented to validate the proposed approach.
5

Sistema inteligente para controle de relés reguladores de tensão / Intelligent system to control voltage regulator relays

Danilo Hernane Spatti 26 February 2007 (has links)
Este trabalho apresenta uma estratégia para realizar o controle de tensão em um sistema de distribuição de energia elétrica dotado de comutadores de tap sob carga. Será investigada a aplicação de sistemas inteligentes para tornar os relés reguladores de tensão mais flexíveis. A inserção de módulos inteligentes em relés reguladores de tensão convencionais irá permitir um melhor aproveitamento das funcionalidades já existentes destes dispositivos. Ainda como foco do estudo, pretende-se atuar apenas na subestação de distribuição, realizando medições no barramento secundário e tomando medidas de controle também neste barramento. A capacidade dos sistemas fuzzy em tratar informações incertas, bem como sua potencial aplicabilidade em problemas tendo comportamentos não previsíveis, permitiram a criação de uma estratégia de controle de tensão que atende todas as regulamentações dos órgãos fiscalizadores e, também, os anseios das concessionárias de distribuição de energia elétrica devido aos resultados promissores obtidos em simulação com dados reais das subestações. / This work presents an approach to voltage control in power distribution systems with load tap changers. Intelligent approaches are studied and applied in voltage regulator relay in order to improve the voltage profiles of the system. The proposal of this work is the addition of fuzzy modules in the conventional voltage regulator relays, which allows the exploration of the main functionalities already implemented in such devices. The adaptive fuzzy voltage regulator relay controls the voltage in the distribution substation, monitoring electrical variables and performing the regulation on secondary bus based on the results provided by the fuzzy modules, which are capable to take into account the voltage profile standards for distribution systems as well as operational interests defined by electrical distribution companies. Simulation results using real data from substations are presented to validate the proposed approach.
6

Estudo experimental do tempo de recuperação de falhas em comutadores de caminhos óticos

Arnar, Claudecir Lopes January 2012 (has links)
Orientador: Gustavo Souza Pavani. / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia da Informação.
7

Aprovisionamento dinâmico de caminhos óticos em redes de transporte ótica G.709 controladas por GMPLS e com restrições de camada física

Jatoba Neto, Alaelson de Castro January 2011 (has links)
Orientador: Gelio Mendes Ferreira / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia da Informação, 2011
8

Comutador eletrônico de taps aplicado a um transformador de distribuição monofásico / Electronic on load tap changer applied to a singlephase distribution transformer

Quevedo, Josemar de Oliveira 27 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Voltage regulation still is a problem faced by power utilities currently. In addition to the series impedance and the significant load variation of the distribution grids, the main causes of voltage regulation problems, the requirements for the enhancement of power quality by the electricity regulatory agencies, increasing energy consumption, the inclusion of distributed generation and the development of the smart grids tends to increase the complexity of the distribution systems. One of the most used methods for voltage regulation in alternating current systems is the employment of tap changer on transformers, this method allows voltage regulation by varying the transformation ratio, modifying the value of the secondary voltage. The application of these devices is primarily performed by manual commutation mechanical devices in distribution systems, and by automatic electromechanical on load tap changers in substations. In the case of manual devices, operating costs and the impossibility of automatic voltage regulation are limiting factors, while in the case of electromechanical devices the limitations are mainly related to the costs of employment and maintenance. Currently, the increase of voltage and current operating levels of semiconductor devices has allowed envision the application of semiconductor switches instead of the mechanical switches employed nowadays. However, due to the operating characteristics of these devices, a detailed analysis of the commutation process is necessary, in order to allow the proper design of the devices involved in the commutation and protection process of the electronic tap changer. In this context, this work presents the analysis, design and implementation of an electronic on load tap changer applied to a single-phase distribution transformer, proposed as an alternative to the existing mechanical and electromechanical tap changers. Such a system enables the automatic voltage regulation, avoiding the insulation oil degradation, resulting from the commutation process, and also the elimination of movable parts, the main cause of defects in current automatic commutation devices. In addition to allowing steady state voltage regulation, the system allows the regulation for momentary voltage sags, since they occur in the transformer operating range. The analysis of the commutation process is presented, allowing the design of the electronic switches, as well as the protection system to be employed. Experimental results show the correct voltage regulation for different kinds of load, demonstrating the potential application of electronic on load tap changers in the current distribution systems and in future smart grids. / A regulação dos níveis de tensão é um problema ainda enfrentado pelas companhias concessionárias de energia elétrica atualmente. Além da impedância série e da significativa variação de carga das linhas de distribuição, principais causas dos problemas de regulação, a maior exigência dos agentes reguladores do sistema elétrico para a melhoria da qualidade de energia, o aumento do consumo de energia, a inclusão de geração distribuída e o desenvolvimento das redes inteligentes (smart grids), tendem a aumentar a complexidade dos sistemas de distribuição. Um dos métodos mais empregados na regulação de tensão em sistemas de corrente alternada é a aplicação de comutadores de taps em transformadores. Este método permite a regulação da tensão através da variação da relação de transformação, modificando o valor da tensão secundária. A aplicação desta solução é feita, majoritariamente, através de dispositivos mecânicos de comutação manual nos sistemas de distribuição e de dispositivos automáticos eletromecânicos de comutação sob carga em subestações. No caso dos dispositivos manuais, os custos operacionais e a impossibilidade da regulação automática de tensão são fatores limitantes, enquanto que no caso dos dispositivos eletromecânicos, os limitantes estão relacionados principalmente aos custos de implantação e de manutenção. Atualmente, o aumento dos níveis de tensão e corrente de operação dos dispositivos semicondutores tem permitido vislumbrar a aplicação de chaves semicondutoras em substituição às chaves mecânicas empregadas. Entretanto, devido às características de funcionamento destes dispositivos, uma análise detalhada do processo de comutação do sistema é necessária, de modo a permitir um adequado projeto dos dispositivos envolvidos no processo de comutação e proteção dos comutadores eletrônicos de taps. Neste contexto, o presente trabalho apresenta a análise, projeto e implementação de um comutador eletrônico de taps aplicado a um transformador de distribuição monofásico, proposto como alternativa aos comutadores mecânicos ou eletromecânicos existentes. Tal sistema permite a regulação automática da tensão, eliminando o desgaste do óleo isolante, resultante do processo de comutação sob carga e também a eliminação de partes móveis, principal causa de defeitos nos comutadores automáticos atuais. Além de permitir a regulação da tensão em regime permanente, o sistema possibilita a regulação para afundamentos de tensão momentâneos, desde que estejam na faixa de operação do transformador. A análise do processo de comutação do dispositivo estudado é apresentada, permitindo o projeto das chaves eletrônicas, bem como do sistema de proteção a ser empregado. Resultados experimentais demonstram a correta regulação de tensão do sistema desenvolvido, dentro dos limites de operação do transformador, para diferentes tipos de carga, evidenciando a potencialidade dos comutadores eletrônicos de taps em aplicações nas atuais redes de distribuição e nas futuras redes inteligentes.
9

Sobre uma Construção Relacionada ao Quadrado Tensional não-Abeliano de um Grupo / On a Construction Related to the non-Abelian Tensor Square of a Group

ANDRADE, Agenor Freitas de 01 July 2011 (has links)
Made available in DSpace on 2014-07-29T16:02:18Z (GMT). No. of bitstreams: 1 Dissertacao Agenor Freitas de Andrade.pdf: 1042479 bytes, checksum: 049cc003452cdaee484bef8ab2c371b3 (MD5) Previous issue date: 2011-07-01 / Let G and Gj be isomorphic groups. We study the group V (G) which is an extension of the non-abelian tensor square of a group G, G G. Looking for V (G) as an operator in the class of groups, we observe that this operator preserves some properties of the group G such as finiteness, nilpotency and solubility. For a p-group finite G we find an upper bound for the order of G G. Finally, we verified computationally, for some groups, and that the results and also the bounds for the orders of the groups shown here are actually respected. / Sejam G e Gj grupos isomorfos. Estudaremos o grupo V (G) que é uma extensão de grupo do quadrado tensorial não-abeliano de um grupo G, G G. Olhando para V (G) como um operador na classe de grupos, observamos que este operador preserva algumas propriedades do grupo G, tais como finitude, solubilidade e nilpotência. Ainda para um p-grupo finito G encontramos um limitante para ordem de G G: Por fim, verificamos computacionalmente, para alguns grupos, que os resultados e também os limitantes para as ordens dos grupos aqui apresentados são de fato respeitados.
10

METODOLOGIA PARA REDUÇÃO DE CUSTOS NA MANUTENÇÃO DOS COMUTADORES DE TAP SOB CARGA DOS TRANSFORMADORES DE POTÊNCIA DE EXTRA ALTA TENSÃO DA ELETRONORTE / THE COST OF MAINTENANCE TRANSFER UNDER LOAD TAP OF THE TRANSFORMERS POWER OF EXTRA HIGH VOLTAGE THE ELETRONORTE

Rosa Filho, Raimundo Nonato 31 March 2005 (has links)
Made available in DSpace on 2016-08-17T14:52:58Z (GMT). No. of bitstreams: 1 Raimundo Nonato Rosa Filho.pdf: 1125835 bytes, checksum: 91689e7b58443f6d0eb73d752860ce37 (MD5) Previous issue date: 2005-03-31 / In this work a methodology for reduction of maintenance cost in the on-load tap changers (OLTC) of extra high voltage is proposed. The methodology is based on the use of Artificial Neural Networks (ANN) for the intelligent processing of input signals of the commutator. The neural nets adequately trained allow to create an information system and dedicated diagnosis of the OLTC. This system can interpret and diagnosis the components through the real time input signals in order to delay the power transformer maintenance intervals, foreseeing when the OLTC is going to maintenance have intervention based on its condition. It has been adopted a multiperceptron ANN architecture in which the input vector has 22 components and the output considers only one component with the status of the OLTC condition in function of its operation time. This output information is used to determine the periods of maintenance of the commutators. It is reported an application of the proposed system considering the on load tap changer of an autotransformer bank of 500/230/13.8 kV, 600MVA of Centrais Elétricas do Norte do Brasil S/A (ELETRONORTE). The results indicate the advantages of the maintenance based on the condition using ANN. / Neste trabalho é proposta uma metodologia para redução de custo de manutenção nos comutadores de tap sob carga (OLTC) dos transformadores de potência de extra alta tensão. A metodologia está baseada na utilização de redes neurais artificiais (RNA) para o processamento inteligente dos sinais de entrada dos comutadores. As redes neurais adequadamente treinadas permitem criar um sistema de informação e diagnóstico dedicado a OLTC que podem interpretar e diagnosticar os componentes através das entradas em tempo real de forma a, postergar os intervalos de manutenção, prevendo quando o OLTC deverá sofrer intervenção de manutenção baseada na condição do OLTC. Foi adotada uma arquitetura de RNA de multiperceptron na qual a entrada considera um vetor com 22 entrada e apenas uma saída com o status da condição do OLTC em função do tempo de operação. Essa informação de saída é utilizada para determinar os períodos de manutenção dos comutadores de tap. É realizada uma aplicação do sistema proposto considerando o comutador de tap sob carga de um banco de autotransformador de 500/230/13.8kV, 600MVA da Centrais Elétricas do Norte do Brasil S/A( ELETRONORTE) e os resultados indicam as vantagens da manutenção baseada na condição usando RNA.