• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A influência das reclamações dos condicionadores WRAC na satisfação dos clientes

Silva, Gilsomar Gabriel da January 2002 (has links)
As organizações com o objetivo de ser cada vez mais competitivas em um mundo globalizado e extremamente competitivo buscam oferecer produtos e serviços que agreguem valor aos seus clientes, aumentando, assim, sua satisfação. A insatisfação dos clientes, especificamente, tem se mostrado de grande importância, pelos seus impactos negativos no desempenho econômico de médio e longo prazo nos resultados das empresas, e não nos seus aspectos de curto prazo. Este trabalho se constituiu na realização de uma pesquisa descritiva sobre a satisfação dos consumidores de condicionadores de ar tipo WRAC da Springer Carrier onde foram levantados os atributos considerados importantes para os clientes, o nível de importância destes atributos, o nível de satisfação em relação a estes atributos e as conseqüências da insatisfação destes consumidores. Este trabalho foi realizado com 300 clientes que reclamaram ao call center da Springer Carrier. Entre as conclusões encontram-se os atributos onde os consumidores apresentam maior insatisfação, sendo eles o serviço pós-venda e a assistência técnica e finalmente sugestões para a empresa. / The organization’s which their main goal consists on being more competitive in a globalized and extremely competitive world, are trying to offer to their customers products and services that add value and increase customers satisfaction. Dissatisfaction is very important to companies, since it has a big impact in the financial results at medium and long term. This job consists in a descriptive study about the Springer Carrier WRAC(Window Room Air Conditioning) customers satisfaction. Through the qualitative study we identified the most important products features and dissatisfaction causes, which had their level of importance and satisfaction measured through a structured questionnaire. Besides, we identified some of the consequences of dissatisfaction, as well as the likelihood of the customers on expressing these behaviors. The survey was applied to 300 customer’s which had problems and had claimed to Springer Carrier by the calling the Call Center department. Among our conclusions, we found that the attributes which the customers are more dissatisfied with after-sales and technical support. Also, the managerial implications may be highlighted.
2

Análise de um condicionador de ar automotivo utilizando o efeito termoelétrico

Leticia Borges Silverio 15 December 2012 (has links)
Este trabalho tem por objetivo apresentar um estudo de viabilidade técnica da utilização de módulos termoelétricos para condicionamento de ar automotivo, com ênfase ao sistema de resfriamento. O sistema termoelétrico de refrigeração baseiase no efeito descoberto por Jean Charles Athanase Peltier em 1834, onde uma corrente elétrica flui na junção de dois materiais semicondutores de propriedades diferentes fazendo com que haja um gradiente de temperatura na junção dos materiais. Os módulos termoelétricos são fabricados por materiais semicondutores selados entre duas placas e, conforme o sentido que a corrente flui, uma superfície da placa torna-se aquecida e a outra resfriada. A refrigeração proveniente dos fenômenos termoelétricos surgiu como uma alternativa aos meios convencionais de refrigeração, pois não gera impactos ambientais, não produz barulho, não possui partes móveis, podendo ser montando em variadas posições de acordo com a necessidade, além de ocupar um volume pequeno em comparação com os outros sistemas. Os efeitos termoelétricos e suas aplicações são apresentados neste estudo, assim como o modelo matemático do sistema de refrigeração, que permite determinar o desempenho do sistema. Dissipadores de calor comercialmente disponíveis são analisados para a determinação da melhor troca térmica para o sistema e protótipos são montados para a obtenção de resultados experimentais de um refrigerador, a fim de verificar sua viabilidade e funcionalidade. / This paper aims to present a technical feasibility study of the use of thermoelectric modules for automotive air conditioning, with emphasis on the cooling system. The thermoelectric cooling system is based on the effect discovered by Jean Charles Athanase Peltier in 1834, where an electric current flows at the junction of two semiconductor materials of different properties so that there is a temperature gradient at the junction of the materials. The thermoelectric modules are manufactured by semiconductor material sealed between two sheets and, as the current flows, a plate surface becomes heated and the other cooled. Thermoelectric cooling from phenomena like Peltier effect has emerged as an alternative to conventional cooling systems, it does not generate environmental impact, do not produce noise, has no moving parts, the system can be mounted in various positions according to the need, and occupies a small volume in comparison with other systems. Thermoelectric effects and their applications are presented in this study, as well as the mathematical modeling of the cooling system, which determines system performance. Heat sinks commercially available are analyzed for determining the best heat transfer to the system and prototypes are assembled to obtain the experimental results for a refrigerator in order to verify its feasibility and functionality.
3

[pt] MÉTODOS DE HORIZONTE MÓVEL NÃO LINEARES APLICADOS AO CONTROLE E ESTIMAÇÃO DE PARÂMETROS DE CONDICIONADORES DE AR / [en] NONLINEAR RECEDING-HORIZON METHODS APPLIED TO CONTROL AND PARAMETER ESTIMATION OF AIR CONDITIONERS

EDSON SABINO DA SILVA 10 December 2021 (has links)
[pt] O setor de refrigeração tem um papel fundamental e crescente na vida moderna. Seus usos vão desde processos industriais até conservação de alimentos passando por aplicações de conforto térmico. Tamanho peso econômico também se reflete nas emissões de poluentes do segmento. Acordos internacionais têm sido implementados com o objetivo de substituir fluidos refrigerantes que são danosos à camada de ozônio ou com alto potencial de aquecimento global. Outras abordagens visam reduzir o nível de emissões por meio da diminuição do consumo energético da operação de sistemas de refrigeração. Nesse sentido, este trabalho investiga a implementação de uma estratégia baseada em controle preditivo para sistemas de expansão direta. O objetivo foi verificar se o controlador baseado nessa abordagem seria capaz de controlar a temperatura interna de um ambiente. Os resultados mostram que o controlador proposto foi eficaz nessa tarefa para o caso de temperaturas externas constantes, porém ineficaz em contexto dinâmico. Quando o desempenho dessa abordagem foi comparado àquele de um mesmo sistema operando com controlador de duas velocidades, os resultados foram inferiores. A estratégia de controle preditivo foi capaz de manter a temperatura do ambiente refrigerado dentro da faixa desejada em 53 por cento do tempo contra 96 por cento do esquema de duas velocidades. Em paralelo, estudou-se também a aplicação do método de estimação estados em horizonte móvel. O objetivo foi discutir se era possível inferir parâmetros do ciclo de refrigeração sem efetivamente mensurá-los. Os resultados mostram que o modelo de refrigeração proposto é observável em condições externas constantes. Além disso, uma comparação de desempenho entre o sistema operando com fluidos diferentes foi realizada. O intuito foi mostrar as possibilidades do método de estimação no que tange o cálculo de indicadores de desempenho. / [en] The refrigeration sector has a fundamental and growing role in modern life. Its uses range from industrial processes and food preservation to applications of thermal comfort. Its economic weight size is reflected in the level of pollutant emissions of the segment. International agreements have been implemented with the objective of replacing refrigerant fluids that are harmful to the ozone layer or with a high global warming potential. These initiatives seek to mitigate the direct impact of the release of gases into the atmosphere. Other approaches aim to reduce the level of emissions by reducing the energy consumption of the operation of these systems.In this sense, this work investigates the implementation of a strategy based on predictive control for direct expansion systems. The objective was to verify if the control strategy based on this approach would be able to keep the internal temperature of an room within a defined range. The results show that the proposed control scheme was effective for the case of constant external temperatures, but ineffective in a dynamic context. Comparing the performance of this approach to the same system operating with a two velocities control scheme, the results were inferior. The predictive control strategy was able to keep the temperature within the desired range in 53 per cent of the simulation time versus 96 per cent of the two velocity aproach. In parallel, the application of the estimation method states in moving horizon was also studied. The objective was to discuss whether it was possible to infer parameters of the refrigeration cycle without actually measuring them. The results show that the refrigeration model proposed is observable under constant external conditions. In addition, a performance comparison between the system operating with different fluids was performed. The goal was to show the possibilities of this estimation method with respect to the calculation of performance metrics.
4

Análise teórica e experimental do comportamento de um trocador de calor geotérmico

Martins, William Marques 23 December 2015 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-10-11T16:43:10Z No. of bitstreams: 1 William Marques Martins_.pdf: 6862880 bytes, checksum: 7ab899b6cdbfc9789b0b9a42720e96f6 (MD5) / Made available in DSpace on 2016-10-11T16:43:10Z (GMT). No. of bitstreams: 1 William Marques Martins_.pdf: 6862880 bytes, checksum: 7ab899b6cdbfc9789b0b9a42720e96f6 (MD5) Previous issue date: 2015-12-23 / FAPERGS - Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul / UNISINOS - Universidade do Vale do Rio dos Sinos / Este trabalho apresenta um estudo teórico e experimental de um trocador de calor geotérmico, tipo helicoidal água-solo, para uso como condensador em um sistema de ar condicionado. Para o experimento foi construída uma bancada composta basicamente por um reservatório térmico, uma bomba d’água, medidor de vazão, um trocador de calor com serpentina tipo helicoidal com comprimento e diâmetro de 3 e 0,27 m, respectivamente e enterrado verticalmente no solo no sentido do comprimento. Foi utilizado um sistema de aquisição de dados conectado a um computador para monitorar sete sensores de temperatura: quatro para o trocador e três para a sonda térmica de medição das temperaturas do solo em três profundidades. Os resultados obtidos com o experimento foram utilizados para obtenção da condutividade térmica do solo e, posteriormente, utilizados na comparação com o modelo teórico, elaborado no software EES. A diferença entre os resultados medidos da taxa de transferência de calor e o resultado calculado ficou em torno de 1%. O modelo também foi utilizado para analisar alguns exemplos como calcular a altura necessária do trocador de calor para atender uma determinada demanda de potência térmica para o caso de substituição do condensador de um sistema de ar condicionado. Para isso foram utilizados os dados de um aparelho de ar condicionado tipo Split, com capacidade de refrigeração de 3,52 kW (12.000 Btu/h) para analisar o comportamento do trocador com diferentes condições de projeto, chegando-se a uma profundidade calculada de 37,11 metros para atender a esta demanda. / This work presents a theoretical and experimental study of a coil-type geothermal heat exchanger, water-soil, for use as condenser in an air conditioning system. An experimental bench was constructed to analyses the heat exchanger performance. This experimental facility consists of a thermal reservoir, a water pump and flow meter, a helical heat exchanger with length and diameter of 3 m and 0.27, respectively and buried vertically at this depth. During the experiments were monitored the temperatures in seven points: four in the heat exchanger and three for measuring the soil temperatures at three different depths. The results obtained with the experiments were used to obtain the thermal conductivity of the soil. The same data were used to validated the theoretical model that was implemented in the EES platform. The difference between the measured heat transfer rate and the theoretical results was about 1%. The model was also used to determine the required length of the heat exchanger to suit a particular thermal power demand for the replacement of a condenser of an air conditioning system. For this, we used the data from a split type air conditioning unit, with a condenser thermal capacity of 3,52 kW, and to analyze the behavior of the heat exchanger with various design conditions, coming to a calculated depth 37.11 meters to meet this demand.
5

[pt] ECONOMIA DE ENERGIA COM O USO DE BLOQUEADORES TEMPORAIS EM CONDICIONADORES DE AR / [es] ECONOMÍA DE ENERGÍA CON EL USO DE BLOQUEADORES TEMPORALES EN ACONDICIONADORES DE AIRE / [en] ENERGY SAVING IN AIR CONDITIONERS BY DIRECT LOAD CONTROL

ALEXANDRE CHANTAL GESUALDI 10 November 2005 (has links)
[pt] O objetivo principal desta dissertação é o de buscar formas de modelar e controlar, adequadamente, condicionadores de ar de janela, pois tratam-se de máquinas que possuem um elevado consumo de energia, perdendo somente para o chuveiro elétrico. A contribuição do mesmo para a demanda do setor doméstico é da ordem de 7 %. As pesquisas de posse de eletrodomésticos mostram que somente 6 % dos domicílios têm instalada tal tipo de máquina, o que representa um expressivo potencial de crescimento para os próximos anos na aquisição deste produto. É oportuno observar que em edifí­cios comerciais, 48 % da energia é consumida com refrigeração, o que implica na necessidade de novos projetos em que centrais de grande porte sejam implantadas, visando um gasto comparativamente menor ao somatório de aparelhos individuais. / [en] This work involves the modeling of window air conditioners, with the purpose to obtain the electrical potential consume by itself, related to the medium external temperature. To obtain such goal, it was necessary the study of all features which involve their several components, aiming the conduct fitted from the parts, due to the result expected. It was made a public research with the users from these equipments. From this result, it was developed a stochastic model to be used in energy demand from a specific region, considering that the equipment / machine in use shows similar qualifications. After that, it was added to the system of machine a direct load control, which delay the compressor, obtaining an efficient working from it (saving demand), without affecting deeply normal using conditions. Finally, comparing two examples mentioned above, it was concluded that in the less powerful equipment (air conditioner) the thermal control with changed features, had good results, while more powerful equipments are more economic with direct load control. / [es] Esta disertación tiene como objetivo principal buscar formas de modelar y controlar adecuadamente, equipos de aire acondicionado de tipo ventana, por tratarse de equipos que poseen un alto consumo de energía, superado tan solo por la ducha eléctrica. La contribución de éste para la demanda del sector doméstico es del orden de 7 %. Las investigaciones sobre la pose de electrodomésticos muestran que sólo el 6 % de los domicilios tiene instalada tal tipo de máquina, lo que representa um expresivo potencial de crescimiento en la adquisición de este producto para los próximos años. Es oportuno observar que en edificios comerciales, 48 % de la energia consumida se refiere a refrigeración, lo que nos lleva a la necesidad de nuevos proyectos donde, centrales de grande porte seam implantadas, para conseguir un gasto comparativamente menor a la suma de equipos individuales.

Page generated in 0.0985 seconds