• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 477
  • 325
  • 44
  • 43
  • 20
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1115
  • 489
  • 447
  • 405
  • 327
  • 326
  • 292
  • 292
  • 87
  • 87
  • 75
  • 69
  • 67
  • 62
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Desenvolvimento e aplicação do cone sísmico

Scheffer, Leandro January 2005 (has links)
A tendência atual de desenvolvimento de novos equipamentos geotécnicos combina diferentes técnicas, aliando a robustez do ensaio de cone às informações adicionais de outros ensaios. O cone sísmico constitui-se em exemplo típico adotado internacionalmente. Geofones ou acelerômetros podem ser incorporados ao fuste do cone para medida de velocidade de propagação de ondas de compressão e cisalhamento. O cone possibilita uma estimativa da resistência ao cisalhamento de materiais geotécnicos, enquanto as medias sísmicas permitem medir o módulo cisalhante a pequenas deformações. A combinação de valores de resistência e deformabilidade, expressa através da razão entre Go/qc, pode representar uma alternativa importante na caracterização de solos. Nesta dissertação o cone sísmico foi projetado, construído, calibrado e testado no depósito argiloso do Aeroporto Internacional Salgado Filho em Porto Alegre. O equipamento é composto de um módulo onde são acondicionados dois sensores (geofones), distantes de 1,0 m, para a captação das ondas de cisalhamento. Os sinais são captados e enviados para um pré-amplificador com filtro, acondicionado no módulo sísmico, sendo posteriormente conduzidos para um segundo amplificador cuja taxa de amplificação pode ser regulada. O sinal adquirido é armazenado em um computador para análise posterior O ensaio de cone sísmico consiste basicamente na geração de uma onda de cisalhamento na superfície do solo e seu armazenamento com o sistema de aquisição de sinais. A determinação do módulo de cisalhamento é feita através da teoria da elasticidade, medindo-se os tempos de chegada da onda de cisalhamento em cada geofone e calculando-se a velocidade de percurso da onda entre os dois sensores. O trabalho contempla o desenvolvimento do cone sísmico, montagem, calibração e aplicação na Área do Aeroporto Internacional Salgado Filho. Os resultados obtidos são comparados a resultados de ensaios de cross-hole existentes no referido local.
162

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
163

Processo de integração energetica do Cone Sul : considerações sobre o gas natural

Canton, Gentil 22 December 2000 (has links)
Orientador: Moacyr Trindade de Oliveira Andrade / Dissertação (mestrado) - Universidade Estadual de campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T20:32:49Z (GMT). No. of bitstreams: 1 Canton_Gentil_M.pdf: 13436819 bytes, checksum: c011dd522be7d8efb4f5fa79c5fdf320 (MD5) Previous issue date: 2000 / Resumo: A presente Dissertação de Mestrado analisa a importância da interligação energética e seu papel na integração do Cone Sul. fuicialmente apresenta uma evolução histórica do uso da energia e as dificuldades que as sociedades encontram para definir a melhor alternativa energética. Com os choques do petróleo em 1973 e 1979, emergiram no mundo o que se convencionou chamar de grandes rupturas, entre elas a industrial, a financeira e a energética. Essas rupturas provocaram grandes transformações no mundo com a introdução de novos paradigmas, sobretudo aqueles vinculados às exigências das sociedades para se utilizarem de fontes energéticas menos poluidoras. Além disso, verifica-se o esforço do mundo em alterar a sua matriz energética para um modelo mais leve e mais "palatável", em termos ecológicos. Ao mesmo tempo, analisa-se o mundo globalizado dos últimos tempos, com seus efeitos controversos para as sociedades, culminando em pelo menos um denominador comum, qual seja, fazer emergir diversos blocos econômicos internacionais, como forma de autoproteção da própria globalização. No Cone Sul, destaca-se a criação do Mercosul, em 1991, cujo crescimento e consolidação acontecem numa velocidade muito acima da expectativa inicial, mostrando que o melhor caminho é a integração. A energia exerceu um papel preponderante nessa integração, com destaque para o gás natural que apresenta características e especificidades vantajosas, dentro das atuais exigências das sociedades de se direcionar para fontes energéticas mais limpas, mais leves e economicamente mais viáveis. Com tais condições vantajosas do gás natural, começa-se a desenhar uma rede de gasodutos no Cone Sul, formando um anel com diversos elos que caracterizam a interligação e consolida a integração / Abstract: The present Master Dissertation analyses the importance of the energy interconnection and it is role in the integration of South America. It is initially presented a historical evolution of the energy use, and the difficulties found by the society in defining the best energy altematives. In 1973 and 1979 with the oil price shock, it emerged in the world what was conventionally called the great ruptures, involving the industrial, financial and energy-system ruptures. Great changes followed those ruptures with the adoption of new paradigms, especially those constrained to the society demands in order to make use of less polluting energy resources, and then change the world energy mix into a environmentfriendly model. At the same time, it is made an analysis of the present globalized world, its contrasting effects upon the society, reaching at least a commonplace, the emergence of several intemational economic blocks, as a form of protection to the globalization process itself. In Southem Cone it must be pointed out the creation of Mercosur in 1991, which growing and consolidation are happening at a speed much higher than expected, showing that the integration of markets is the best way. The energy sector played a decisive role in this integration process, with prominence for the natural gas that presents advantageous features demanded by the society which requires c1eaner, lighter and economically more viable energy sources. Considering those advantages of natural gas, it has been set up a network of pipelines in the Southem Cone, forming a ring composed by several links that characterize interconnection and consolidate integration / Mestrado / Planejamento de Sistemas Energeticos / Mestre em Engenharia Mecânica
164

Validity of water and acrylic as soft tissue simulation materials in an in vitro study using cone beam computed tomography / Validade da água e acrílico como materiais simuladores de tecidos moles em estudo in vitro realizado com tomografia computadorizada de feixe cônico

Visconti, Maria Augusta Portella Guedes, 1985- 24 August 2018 (has links)
Orientador: Francisco Haiter Neto / Texto em português e inglês / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T17:16:38Z (GMT). No. of bitstreams: 1 Visconti_MariaAugustaPortellaGuedes_D.pdf: 2357684 bytes, checksum: ed042e1f5da51d27eae5691a052e4cc3 (MD5) Previous issue date: 2014 / Resumo: O presente estudo propôs-se validar os materiais água e acrílico como simuladores de tecidos moles em um estudo in vitro realizado com tomografia computadorizada de feixe cônico (TCFC). Para isso foram utilizadas três cabeças humanas, com tecidos moles intactos, para determinação do padrão-ouro. Essas cabeças foram submetidas a exames de TCFC e posteriormente descarnadas e tomografadas novamente, agora com diferentes tipos de simuladores de tecido mole, seguindo o mesmo protocolo de aquisição. Para simulação dos tecidos moles foram confeccionadas três caixas de acrílico com diferentes dimensões e espessuras. Estas caixas foram utilizadas isoladamente, conjugadas entre si e em combinação com a água, totalizando dez diferentes tipos de simuladores. Um único avaliador experiente realizou as mensurações em quatro regiões de interesse para maxila e mandíbula, incluindo dentes e ossos alveolares. As regiões de interesse consistiram em áreas quadrangulares, nas quais foram determinados todos os valores de cinzas expressos em pixels. Os resultados mostraram que tanto a região avaliada quanto os tipos de simuladores testados interferiram diretamente nos valores de pixels obtidos. As caixas de acrílico de 0,5 e 1,5 cm de espessura foram os simuladores que mais se assemelharam ao padrão-ouro, não apresentando diferença significativa. No entanto, essa similaridade apenas foi observada para a maxila, limitada às regiões dos dentes e ossos alveolares anteriores. A simulação dos tecidos moles realizada apenas com o acrílico foi a que mais se aproximou dos tecidos moles humanos nas imagens de TCFC, apenas para maxila / Abstract: The aim of this study was to validate the materials water and acrylic as soft tissue simulators in an in vitro study conducted with cone beam computed tomography (CBCT). For this we used three human heads, with soft tissues intact, to determine the "gold standard". These heads were submitted to CBCT exams, and subsequently stripped and scanned again, this time with different types of soft tissue simulators, following the same acquisition protocol. For soft tissue simulation, three acrylic boxes of differing dimensions and thicknesses were prepared. These boxes were used separately, combined together, and in combination with water, totaling ten different types of simulators. A single experienced evaluator did measurements in four regions of interest for the maxilla and mandible, including teeth and alveolar bone. The regions of interest consisted of quadrangular areas, in which all gray values were determined, expressed in pixels. The results sowed both the region evaluated as well as the types of simulators tested directly affected the pixel values obtained. The acrylic boxes with 0.5 and 1.5 cm thickness were the simulators that more closely resembled the gold standard, presenting no significant difference. However, this similarity was observed only for the maxilla, limited to the anterior tooth and alveolar bone regions. The simulation of soft tissues done solely with acrylic was the one closest to human soft tissues in the CBCT images, only for maxilla / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica
165

Estudo comparativo de medidas lineares em mandíbulas obtidas a partir de dois tomógrafos computadorizados de feixe cônico para o planejamento de implantes dentários / Comparison of linear measurements on jaws obtained from two cone beam CT for dental implants

Aguiar, Luciana Barreto Vieira, 1980- 20 August 2018 (has links)
Orientadores: Glaucia Maria Bovi Ambrosano, Paulo Sérgio Flores Campos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T02:59:51Z (GMT). No. of bitstreams: 1 Aguiar_LucianaBarretoVieira_D.pdf: 775343 bytes, checksum: 32297ad518d640437e10e0db97d996fa (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a validade de medidas verticais lineares para fins de inserção de implantes dentários em mandíbula a partir de imagens paracoronais diagonais (tomógrafo k9000 3D) e imagens paracoronais ortogonais (tomógrafo i-CAT). A amostra consistiu de 11 mandíbulas humanas secas e desdentadas na região posterior. Foram realizadas, a partir dos sítios implantares, três linhas de orientação, desde o rebordo alveolar até a base da mandíbula, simulando o ângulo de implantação dos dentes na base óssea. Para que estas linhas pudessem ser visualizadas nas imagens tomográficas, foram colocadas no rebordo três esferas plásticas, para localização do sítio implantar, e cones de guta percha com 01 cm de espaçamento entre eles. A aquisição das imagens foi procedida nos tomógrafos i-CAT e k9000 3D, de acordo com os protocolos estabelecidos para este fim. Após as aquisições, três avaliadores analisaram as imagens nos softwares i-CAT Vision e do KDIS, dos respectivos tomógrafos. Para a análise das imagens do i-CAT, os avaliadores realizaram cortes paracoronais ortogonais mensurando a partir do rebordo ósseo até o teto do canal mandibular o corte com a imagem da esfera mais nítida. Nas imagens do k9000 3D, os avaliadores realizaram cortes paracoronais diagonais usando a ferramenta do próprio software e mensurando também do rebordo ósseo até o teto do canal mandibular, acompanhando a orientação da guta percha. Os avaliadores realizaram uma segunda mensuração após uma semana. As mandíbulas foram cortadas seguindo a localização e a orientação das linhas previamente tracejadas nos três sítios, sendo as alturas mensuradas com um paquímetro digital desde o rebordo ósseo até o teto do canal mandibular. As medidas assim aferidas foram utilizadas como padrão ouro. Após a tabulação, os dados foram avaliados pela análise de correlação intraclasse e a comparação entre as médias obtidas nos dois tomógrafos com o real foi realizada pelo teste t pareado (?=0,05). Observou-se que o coeficiente de correlação intraclasse intra-avaliadores foi excelente (variando de 0,98 a 0,99) para os dois tomógrafos. Para a primeira e a segunda avaliação o ICC interavaliadores para os dois tomógrafos foi de satisfatório a excelente: 0,72 a 0,99 e 0,69 a 0,98 respectivamente. Quando comparados os avaliadores com o padrão ouro, o ICC foi excelente variando de 0,76 a 0,87 e 0,82 a 0,89, para o i-CAT e o k9000 3D, respectivamente. Os resultados do ICC para os tomógrafos comparados com o padrão ouro foram excelentes (0,88 e 0,94). O resultado da estatística descritiva obteve um valor de p= 0,0002 com uma média de 13,5 para o i-Cat havendo diferença estatisticamente significativa em relação ao padrão ouro (média 12,5). O k9000 apresentou uma média de 12,7 (p=0,4454) não havendo diferença estatisticamente significativa em relação ao padrão ouro. Dessa forma, pode-se concluir que as medidas verticais reproduzem a condição anatômica e são válidas para fins de inserção de implantes dentários / Abstract: The aim of this study was to evaluate the validity of vertical linear measurements for the purpose of inserting dental implants in the mandible using diagonal parasagittal images (K9000 3D Tomograph) and orthogonal parasagittal images (i-CAT Tomograph). The sample consisted of 11 dry, human mandibles, edentulous in the posterior region. From the implant sites, three orientation lines were drawn from the alveolar ridge to the base of the mandible, simulating the angle of implantation of teeth in the bony base. So that these lines could be visualized in the tomographic images, three plastic spheres were placed on the ridge to localize the implant site, and gutta percha cones spaced at a distance of 01cm between them. Image acquisition was performed with i-CAT and K9000 3D tomographs, in accordance with the protocols established for this purpose. After acquisition, three evaluators analyzed the images by means of i-CAT Vision and KDIS software of the respective tomographs. For analysis of i-CAT images, the evaluators made parasagittal orthogonal cuts measuring the cut with the most nitid image of the sphere from the bone ridge up to the roof of the mandibular canal. In the images of the K9000, the evaluators made diagonal parasagittal cuts using the tool of the software itself and also measured from the bone ridge up to the roof of the mandibular canal, following the orientation of the gutta percha. The evaluators made a second measurement after one week. The hemi-mandibles were cut following the localization and orientation of the previously traced lines in the three sites, with the heights being measured with a digital pachymeter from the bone ridge up to the roof of the mandibular canal. The measurements thus checked were used as the gold standard. After tabulation, the data were evaluated by the interclass correlation analysis. The results demonstrated that the intraclass intra-evaluator coefficient of correlation was excellent (ranging from 0.98 to 0.99) for the two Tomographs. For the first and second evaluation the inter-evaluator ICC for the two tomographs was from satisfactory to excellent: 0.72 to 0.99 and 0.69 to 0.98 respectively. When the evaluators were compared with the gold standard, the ICC was excellent variation from 0.76 to 0.87 and 0.82 to 0.89, for i-CAT and K9000 3D, respectively. The results of the ICC for the tomographs compared with the gold standard were excellent (0.88 and 0.94). Thus, it could be concluded that the vertical measurements reproduced the anatomic condition and are valid for the purpose of inserting dental implants / Doutorado / Radiologia Odontologica / Mestre em Radiologia Odontológica
166

Mandibular condyle dimensions in Peruvian patients with Class II and Class III skeletal patterns.

Zegarra-Baquerizo, Hugo, Moreno-Sékula, Katica, Casas-Apayco, Leslie, Ghersi-Miranda, Hugo 26 October 2017 (has links)
Objective: To compare condylar dimensions of young adults with Class II and Class III skeletal patterns using cone-beam computed tomography (CBCT). Materials and methods: 124 CBCTs from 18-30 year-old patients, divided into 2 groups according to skeletal patterns (Class II and Class III) were evaluated. Skeletal patterns were classified by measuring the ANB angle of each patient. The anteroposterior diameter (A and P) of the right and left mandibular condyle was assessed from a sagittal view by a line drawn from point A (anterior) to P (posterior). The coronal plane allowed the evaluation of the medio-lateral diameter by drawing a line from point M (medium) to L (lateral); all distances were measured in mm. Results: In Class II the A-P diameter was 9.06±1.33 and 8.86±1.56 for the right and left condyles respectively, in Class III these values were 8.71±1.2 and 8.84±1.42. In Class II the M-L diameter was 17.94±2.68 and 17.67±2.44 for the right and left condyles respectively, in Class III these values were 19.16±2.75 and 19.16±2.54. Conclusion: Class III M-L dimensions showed higher values than Class II, whereas these differences were minimal in A-P.
167

A cone beam analysis of the maxillary bony canal

Bedford, Mariam January 2013 (has links)
>Magister Scientiae - MSc / Aim: To determine the prevalence and diameter of the maxillary end osseous canal which carries the anastomosis of the infra alveolar artery (a branch of the posterior superior alveolar artery) and the infra- orbital artery. Material and methods: Data was analyzed from one hundred archived cone beam computed tomography (CBCT) images. The presence of the end osseous anastomosis in the lateral sinus wall was identified by utilizing axial views. The vessel diameter was also measured in those images where the canal was identified. Results: The maxillary bony canal was identified in 49 (49%) of 100 maxillary sinus.14 (14%) presented on the right hand side, 10 (10%) presented on the left hand side, 25 (25%) had a bilateral presence with a remaining 51 (51%) which cannot be identified on the imaging. From the 49 canals that were identified, 5 canals had a diameter that was 2-3mm wide,19 canals had a diameter that was 1-2mm wide and the remaining 25 had a diameter that was less than 1mm. Conclusion: A sound knowledge of the maxillary sinus vascularity is essential as severe bleeding can occur due to damage of the intra-osseous branch during sinus augmentation procedures. CBCT analysis is required as a pre-requisite for the pre-planning stages during implant treatment to prevent complications such as haemorrhage, sinus perforations or associated vascular anomalies that may arise
168

Influência da morfologia craniofacial na análise tridimensional das vias aéreas superiores = Influence of craniofacial morphology in the three dimensional analysis of the upper airway / Influence of craniofacial morphology in the three dimensional analysis of the upper airway

Brasil, Danieli Moura, 1988- 02 October 2015 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T19:01:13Z (GMT). No. of bitstreams: 1 Brasil_DanieliMoura_M.pdf: 14824425 bytes, checksum: 3057ff676ccce0f70d5ed273ef3ffed8 (MD5) Previous issue date: 2015 / Resumo: O objetivo deste estudo foi avaliar a influência da morfologia craniofacial em volumes e áreas transversais das vias aéreas superiores. Para isso, foram utilizadas 74 imagens por Tomografia Computadorizada de Feixe Cônico (TCFC) e 74 fotografias faciais em perfil lateral, que pertenciam aos mesmos pacientes, sendo 38 do sexo masculino e 36 do sexo feminino, com idades entre 18 e 56 anos (32,8 ± 1,8). As imagens foram selecionadas a partir de um arquivo de exames de pacientes atendidos em uma Clínica de Radiologia. Um radiologista experiente classificou a amostra em tipos esqueléticos ântero-posteriores (classe II e classe III) empregando a análise cefalométrica de Steiner e a medida AO-BO de Jacobson; e em padrões verticais (braquifacial, mesofacial e dolicofacial) utilizando a análise cefalométrica de Ricketts. A análise facial de perfil foi realizada para cada paciente. Medidas de volume total, de nasofaringe e de orofaringe e ainda de cinco áreas transversais ao longo das vias aéreas superiores foram realizadas, utilizando o software Insight ITK-SNAP 2.4.0®. Os resultados foram submetidos à análise estatística, em que o teste Mann-Whitney foi utilizado para analisar a influência do sexo e dos tipos esqueléticos ântero-posteriores nas variáveis do estudo, o teste Kruskal-Wallis foi aplicado para verificar a existência de relação entre os padrões verticais e as variáveis; o teste de Correlação de Spearman foi utilizado para analisar a possível correlação entre as medidas dentro dos padrões esqueléticos ântero-posteriores, dentro dos padrões verticais e dentro das variáveis da análise facial e as demais medidas propostas pelo estudo. Os resultados mostraram que o tipo esquelético ântero-posterior e o padrão vertical da face não influenciaram no volume das vias aéreas superiores; a área transversal na região de palato mole (PM) mostrou-se significativamente maior para classe III; o terço superior da face apresentou correlação negativa com as medidas da faringe e o terço médio da face mostrou correlação positiva com a área transversal PM. Concluiu-se que os padrões faciais não influenciaram no volume da faringe e que a observação fotográfica do perfil facial foi capaz de mostrar tendências de correlações entre terços da face e vias aéreas superiores / Abstract: The aim of this study was to evaluate the influence of craniofacial morphology in volumes and cross-sectional areas of the upper airway. For this 74 Cone Beam Computed Tomography (CBCT) images and 74 facial photographs in side profile were used, which belonged to the same patients, 38 males and 36 females, aged between 18 and 56 years (32.8 ± 1.8). The images were selected from a file examination of patients seen in a Radiology Clinic. An experienced radiologist classified the sample into anteroposterior skeletal types (class II e class III) using Steiner¿s analysis and the AO-BO measure Jacobson; and into vertical groups (brachyfacial, mesofacial and dolichofacial) using Ricketts¿ analysis. The facial profile analysis was performed for each patient. Measurement of volume and of five cross-sectional areas of upper airway were performed using Insight ITK-SNAP 2.4.0®. The data was subjected to statistical analysis, the Kruskal-Wallis test was used to verify the existence of a relationship between the vertical groups and other variables analyzed in the study. The Mann-Whitney test was used to analyze the influence of gender and anteroposterior skeletal types in the variables. Spearman Correlation test was used to analyze the possible correlation between measurements within vertical groups; within the anteroposterior skeletal types; and within variables of facial analysis, and other measures proposed by the study. Results showed that the anteroposterior skeletal type and the vertical pattern did not influence the volume of the upper airway; soft palate (SP) cross-sectional area was significantly greater in type class III; the upper facial third was negatively correlated with measures of the pharynx, and the middle facial third had positive correlation with the SP cross-sectional area. It was concluded that facial patterns do not influence the pharynx volumes. The photographic observation of the facial profiles is able to show trends of correlations between thirds of the face and upper airway / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
169

Avaliação de diferentes materiais simuladores de tecidos moles nos valores de tons de cinza em imagens de tomografia computadorizada de feixe cônico / Evaluation of different soft tissue simulator materials in gray values in cone beam computed tomography

Santaella, Gustavo Machado, 1989- 27 August 2018 (has links)
Orientador: Luciana Asprino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T07:59:26Z (GMT). No. of bitstreams: 1 Santaella_GustavoMachado_M.pdf: 1130922 bytes, checksum: 73dd73d086d83d2c9e2fa04c5f9cd294 (MD5) Previous issue date: 2015 / Resumo: Os fótons de raios X são atenuados quando atravessam materiais, e isso afeta diretamente os valores dos tons de cinza da imagem. No presente estudo teve-se como objetivos avaliar a utilização de diferentes materiais como simuladores de tecidos moles e avaliar a influência dos tecidos moles nos tons de cinza em imagens de tomografia computadorizada de feixe cônico (TCFC). Para isso, foram utilizadas três cabeças humanas com os tecidos moles formolizados presentes e submetidas à aquisição de imagens de TCFC para determinação do grupo padrão-ouro. Posteriormente, as cabeças foram descarnadas e novamente tomografadas, com e sem a utilização de diferentes materiais simuladores de tecidos moles, seguindo o mesmo protocolo de aquisição. Quatro diferentes materiais foram testados, acrílico, água, cera utilidade e poliestireno expandido (EPS), utilizados isoladamente ou em combinação, totalizando 6 grupos de teste (sem simulador, com caixa de EPS de 2 cm de espessura, com acrílico com 0,5 cm de espessura, com caixa de EPS com cera de 1 cm de espessura, com caixa de EPS com cera de 1 cm de espessura e água no interior, e com caixa de EPS com água no interior). Um único avaliador selecionou oito regiões de interesse quadrangulares, sendo em maxila e mandíbula e incluindo dentes e ossos alveolares, e realizou as mensurações de todos os valores dos tons de cinza dos pixels das regiões. As medianas desses valores foram utilizadas para comparação pelos testes de Friedman e Dunn. Os resultados mostraram que os grupos testados não apresentaram diferenças estatisticamente significantes em comparação com o grupo padrão-ouro, com exceção dos grupos que envolveram água no interior das caixas. O EPS com 2 cm de espessura, associado ou não a uma camada de cera utilidade de 1 cm, e o acrílico com 0,5 cm de espessura foram os simuladores que forneceram imagens mais semelhantes às imagens do padrão-ouro. A água não se mostrou eficaz como simulador de tecidos moles. Os tecidos moles não influenciaram nos valores de tons de cinza mensurados na imagem de TCFC / Abstract: X-ray photons suffer attenuation as they pass through materials of different compositions, and this directly affects the values of the image grayscale. This study aimed to test the usefulness of different materials as soft tissue simulators and evaluate the influence of soft tissues on grayscale values in cone beam computed tomography (CBCT). Three human heads with formalin fixed soft tissues were obtained and CBCT images were acquired to determine the gold standard group. The heads were stripped and tomographic images reacquired with and without the use of different materials for soft tissue simulation, following the same acquisition protocol. Four different materials were tested, acrylic, water, utility wax and expanded polystyrene (EPS), and these were used singly or in combination, with a total of 6 test groups (no simulator, with EPS box 2 cm thick, with 0.5 cm thick acrylic, EPS box with 1 cm thick wax, EPS box with 1 cm thick wax and water inside, and EPS box with water inside). A single evaluator selected the eight quadrangular regions of interest, being in the maxilla and mandible and including teeth and alveolar bone, and performed the measurements of all the pixel grayscale values of the regions. The median of these values were used for comparison by Friedman's and Dunn's tests. The results showed that the tested groups showed no statistically significant differences compared to the gold standard group, with the exception of groups involving water inside the boxes. The EPS 2 cm thick, associated or not with a 1 cm layer of utility wax, and the 0.5 cm thick acrylic were the simulators that provided images more similar to the gold standard images. The water was not effective as a soft tissue simulator. The soft tissues did not influence the values of the CBCT image grayscale measured / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
170

Copositive programming: separation and relaxations

Dong, Hongbo 01 December 2011 (has links)
A large portion of research in science and engineering, as well as in business, concerns one similar problem: how to make things "better”? Once properly modeled (although usually a highly nontrivial task), this kind of questions can be approached via a mathematical optimization problem. Optimal solution to a mathematical optimization problem, when interpreted properly, might corresponds to new knowledge, effective methodology or good decisions in corresponding application area. As already proved in many success stories, research in mathematical optimization has a significant impact on numerous aspects of human life. Recently, it was discovered that a large amount of difficult optimization problems can be formulated as copositive programming problems. Famous examples include a large class of quadratic optimization problems as well as many classical combinatorial optimization problems. For some more general optimization problems, copositive programming provides a way to construct tight convex relaxations. Because of this generality, new knowledge of copositive programs has the potential of being uniformly applied to these cases. While it is provably difficult to design efficient algorithms for general copositive programs, we study copositive programming from two standard aspects, its relaxations and its separation problem. With regard to constructing computational tractable convex relaxations for copositive programs, we develop direct constructions of two tensor relaxation hierarchies for the completely positive cone, which is a fundamental geometric object in copositive programming. We show connection of our relaxation hierarchies with known hierarchies. Then we consider the application of these tensor relaxations to the maximum stable set problem. With regard to the separation problem for copositive programming. We first prove some new results in low dimension of 5 x 5 matrices. Then we show how a separation procedure for this low dimensional case can be extended to any symmetric matrices with a certain block structure. Last but not least, we provide another approach to the separation and relaxations for the (generalized) completely positive cone. We prove some generic results, and discuss applications to the completely positive case and another case related to box-constrained quadratic programming. Finally, we conclude the thesis with remarks on some interesting open questions in the field of copositive programming.

Page generated in 0.0658 seconds