• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 1
  • Tagged with
  • 11
  • 11
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
2

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
3

Técnicas de redução de potência estática em memórias CMOS SRAM e aplicação da associação de MOSFETs tipo TST em nano-CMOS / Static energy reduction techniques for CMOS SRAM memories and TST MOSFET association application for nano-CMOS

Conrad Junior, Eduardo January 2009 (has links)
Em nossos dias a crescente busca por portabilidade e desempenho resulta em esforços focados na maximização da duração de bateria dos equipamentos em fabricação, ou seja, busca-se a conflitante solução de circuitos com baixo consumo e ao mesmo tempo com alto desempenho. Neste contexto usualmente na composição de equipamentos portáteis empregam-se SOC´s (Systems On Chip) o que barateia o custo de produção e integração destes circuitos. SOC´s são sistemas completos que executam uma determinada função integrados em uma pastilha de silício única, normalmente possuem memórias SRAM como componente do sistema, que são utilizadas como memórias de alta performance e baixa latência e/ou também como caches. O grande desafio de projeto em memórias SRAMS é a relação de desempenho versus potência consumida a ser otimizada. Basicamente por sua construção estes circuitos apresentam alto consumo de potência, dinâmica e estática, relacionada a primeira diretamente ao aumento de freqüência de operação. Um dos focos desta dissertação é explorar soluções para a redução de consumo de energia tanto dinâmica como estática, sendo a redução de consumo estático de células de memória em standby buscando desempenho, estabilidade e baixo consumo de energia. No desenvolvimento de técnicas para projeto de circuitos analógicos em tecnologias nanométricas, os TST´s (T-Shaped Transistors – Transistor tipo T) surgem como dispositivos com características potenciais para projeto analógico de baixa potência. TSTs / TATs (Trapezoidal Associations of Transistors – Associação Trapezoidal de transistores) são estruturas self-cascode que podem tornar-se uma boa escolha por apresentar redução do leakage, redução na área utilizada e com incremento na regularidade do layout e no casamento entre transistores, propriedade importantíssima para circuitos analógicos. Sendo este o segundo foco deste texto através do estudo e análise das medidas elétricas dos TSTs executadas para comprovação das características destes dispositivos. Também apresenta-se uma análise das possibilidades de utilização dos TSTs em projeto analógico para tecnologias nanométricas. / Nowadays the increasing needs for portability and performance has resulted in efforts to increase battery life, i. e., the conflicting demands for low power consumption and high performance circuits. In this context using SOC´s (System On Chip) in the development for portable equipments composition, an integration of an entire system for a given function in a single silicon die will provide less production costs and less integration costs. SOC´s normally include a SRAM memory as its building block and are used to achieve memories with low latency and short access time or (and) as caches. A performance versus power consumption analysis of SRAM memory building blocks shows a great challenge to be solved. The electrical design aspects of these blocks reveal high power consumption, dynamic and static, and the former is directly proportional to the operating frequency. The design space exploration for dynamic and leakage consumption reduction in these circuits is one of the focus of this work. The main contribution of this topic is the leakage reduction techniques based in performance, stability and low energy consumption for the memory cell stand-by mode. Among the electrical techniques developed for analog circuits at the 20-100 nanometer scale, the TST (T-Shaped Transistors) rises with potential characteristics for analog low power design. TST /TAT (Trapezoidal Associations of Transistors) are selfcascode structures and can be turning into a good alternative for leakage and area reduction. Another point is the increment in mismatch and layout regularity, all these characteristics being very important in analog designs. The TST electrical measurements study and analysis are developed to show the device properties. An analysis of the TST desired properties and extrapolation for nanometer technologies analog design are also presented.
4

Determinação de indicadores de eficiência e racionalidade energética na produção de etanol com a aplicação da lógica fuzzy

Halmeman, Maria Cristina Rodrigues [UNESP] 01 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-01Bitstream added on 2014-06-13T19:20:46Z : No. of bitstreams: 1 halmeman_mcr_dr_botfca.pdf: 760209 bytes, checksum: 510075c6d575c0ea80dcb0d121f17318 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O Brasil é o maior produtor mundial de cana-de-açúcar, com expansão de produção acelerada nos últimos anos, movida principalmente, pela elevação do consumo doméstico de etanol e açúcar. O estado de São Paulo concentra a maior quantidade de canaviais do país. O setor sucroalcooleiro produz energia térmica e elétrica suficientes para seus processos de produção e excedentes de energia elétrica que podem ser comercializados. Por esse motivo é necessário estabelecer indicadores energéticos capazes de verificar quais usinas possuem processos eficientes na geração e no consumo de energia elétrica. Desse modo, o objetivo do trabalho foi estabelecer índices de eficiência e racionalidade com base na geração, consumo de energia elétrica, produção de etanol e quantidade de cana-de-açúcar processada para três usinas do setor sucroalcooleiro, utilizando-se análises estatísticas e lógica fuzzy. A aplicação da análise estatística e lógica fuzzy, baseando-se no Fator de Potência (FP) e no Fator de Carga (FC) indicaram a eficiência e racionalidade na forma de utilização da energia elétrica. As três usinas analisadas possuem grande potencial de produção e exportação de açúcar e etanol e estão localizadas na região Centro-Oeste do estado de São Paulo. Os dados coletados na safra 2008/2009 permitiram a avaliação da utilização da energia elétrica em cinco setores de cada usina e estabelecer parâmetros para avaliar o desempenho energético, de forma a classificar sua situação de acordo com as variáveis linguísticas: “Muito Ruim”, “Ruim”, “Médio”, “Bom” e “Muito Bom”, conforme um sistema de controle baseado na lógica fuzzy. A classificação mostrou que a usina USA teve desempenho satisfatório para os setores... / Brazil is the largest producer of sugar cane in the world, with expansion of production accelerated in recent years, driven mainly by rising domestic consumption of ethanol and sugar. The state of São Paulo has the largest amount of sugar plantations in the country. The alcohol sector produces sufficient thermal and electrical energy for its processes of production and exceeding electricity that can be commercialized. For this reason is necessary to establish energy indicators, it show if the plants have efficient processes in the generation and power consumption. Thus, the objective was establish indices of efficiency and rationality based on generation, power consumption, ethanol production and quantity of sugar cane processed for three plants of this sector, using statistical and fuzzy logic. The application of statistical analysis and fuzzy logic, based on Power Factor (PF) and Load Factor (CF) showed the efficiency and rationality in the form of electrical energy is used. The plants analyzed have great potential for production and export of sugar and ethanol, they are in the Midwestern, state of São Paulo. The data collected in the season 2008/2009 allowed the evaluation of the use of electricity in five sectors of each plant and establishing criteria for assessing the energy performance in order to classify their situationaccording to the linguistic variables: Very Poor Bad, Medium, Good and Very Good as a control system based on fuzzy logic. Classification showed that the plant called USA had a satisfactory performance for the areas of reception and extract the juice. The USB power plant was more efficient and rational for the sectors of boiler and distilleries. The plant USC for the juice extraction industry, expressed an excellent performance (high rating), but the same sector at the... (Complete abstract click electronic access below)
5

Determinação de indicadores de eficiência e racionalidade energética na produção de etanol com a aplicação da lógica fuzzy /

Halmeman, Maria Cristina Rodrigues, 1976- January 2012 (has links)
Orientador: Odivaldo José Seraphim / Coorientador: Celso E. Lins de Oliveira / Banca: Luiz Antonio Rossi / Banca: José Angelo Cagnon / Banca: Luis Roberto Almeida Gabriel Filho / Banca: Luiz Antonio Perea / Resumo: O Brasil é o maior produtor mundial de cana-de-açúcar, com expansão de produção acelerada nos últimos anos, movida principalmente, pela elevação do consumo doméstico de etanol e açúcar. O estado de São Paulo concentra a maior quantidade de canaviais do país. O setor sucroalcooleiro produz energia térmica e elétrica suficientes para seus processos de produção e excedentes de energia elétrica que podem ser comercializados. Por esse motivo é necessário estabelecer indicadores energéticos capazes de verificar quais usinas possuem processos eficientes na geração e no consumo de energia elétrica. Desse modo, o objetivo do trabalho foi estabelecer índices de eficiência e racionalidade com base na geração, consumo de energia elétrica, produção de etanol e quantidade de cana-de-açúcar processada para três usinas do setor sucroalcooleiro, utilizando-se análises estatísticas e lógica fuzzy. A aplicação da análise estatística e lógica fuzzy, baseando-se no Fator de Potência (FP) e no Fator de Carga (FC) indicaram a eficiência e racionalidade na forma de utilização da energia elétrica. As três usinas analisadas possuem grande potencial de produção e exportação de açúcar e etanol e estão localizadas na região Centro-Oeste do estado de São Paulo. Os dados coletados na safra 2008/2009 permitiram a avaliação da utilização da energia elétrica em cinco setores de cada usina e estabelecer parâmetros para avaliar o desempenho energético, de forma a classificar sua situação de acordo com as variáveis linguísticas: "Muito Ruim", "Ruim", "Médio", "Bom" e "Muito Bom", conforme um sistema de controle baseado na lógica fuzzy. A classificação mostrou que a usina USA teve desempenho satisfatório para os setores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brazil is the largest producer of sugar cane in the world, with expansion of production accelerated in recent years, driven mainly by rising domestic consumption of ethanol and sugar. The state of São Paulo has the largest amount of sugar plantations in the country. The alcohol sector produces sufficient thermal and electrical energy for its processes of production and exceeding electricity that can be commercialized. For this reason is necessary to establish energy indicators, it show if the plants have efficient processes in the generation and power consumption. Thus, the objective was establish indices of efficiency and rationality based on generation, power consumption, ethanol production and quantity of sugar cane processed for three plants of this sector, using statistical and fuzzy logic. The application of statistical analysis and fuzzy logic, based on Power Factor (PF) and Load Factor (CF) showed the efficiency and rationality in the form of electrical energy is used. The plants analyzed have great potential for production and export of sugar and ethanol, they are in the Midwestern, state of São Paulo. The data collected in the season 2008/2009 allowed the evaluation of the use of electricity in five sectors of each plant and establishing criteria for assessing the energy performance in order to classify their situationaccording to the linguistic variables: "Very Poor" "Bad," "Medium," "Good" and "Very Good" as a control system based on fuzzy logic. Classification showed that the plant called USA had a satisfactory performance for the areas of reception and extract the juice. The USB power plant was more efficient and rational for the sectors of boiler and distilleries. The plant USC for the juice extraction industry, expressed an excellent performance (high rating), but the same sector at the... (Complete abstract click electronic access below) / Doutor
6

Behöver jag verkligen det här? : En kvalitativ studie om effekterna av minskad konsumtion

Andersson, Maria, Sjöström, Jeremy January 2024 (has links)
This study aims to investigate the individual's experience of conscious consumption reduction in relation to society's consumption norms. By not focusing on motives or causes behind the change, but instead illustrating the subjective and social consequences, the study provides a deeper understanding of how the individual's self-perception and social relationships are affected. This will be studied based on the following questions “How does a conscious reduction in consumption affect the individual's self-perception and identity in relation to society's consumption norms?” and “What social and cultural effects do individuals experience when they reduce their consumption on purpose, and how does this affect relationships within the individual's immediate circle?” Previous research has been interested in understanding why individuals change their consumption behaviour. Social resistance from society and the surrounding community has also been a broad area of research. A significant focus has also been to study consumption patterns from a sustainability perspective, where research identifies challenges and how today's society can be treated. This study aims to contribute with an in-depth understanding of how conscious consumption reduction affects the individual's life aspects and relationships, which may have far-reaching implications for our understanding of society's changing consumption patterns. The theoretical framework of the study consists of Emilé Durkheim's social coercion consisting of the normative coercion, the cultural coercion, the material coercion and the structural coercion. In combination with this, Robert K. Merton's social tensions, taken from his strain theory, are also applied. The study is based on qualitative semi-structured interviews, where we study 8 individuals' perceived effects of consumption reductions. The results suggest that a reduction in consumption strengthens the individual's empowerment and promotes self-reflection. Through reduced emphasis on external factors, individuals shape their self-perception beyond materialism. Even though their consumption reduction violates norms, they are met with curiosity. These individuals appear to act as agents of normative change by raising awareness of the impact of consumption and promoting a transformation towards a more sustainable way of living. / Denna studie ämnar undersöka individens upplevelse av medveten konsumtionsminskning i förhållande till samhällets konsumtionsnormer. Genom att inte rikta in sig på motiv eller orsaker bakom förändringen, utan i stället åskådliggöra de subjektiva och sociala konsekvenserna, ger studien en djupare förståelse för hur individens självuppfattning och sociala relationer påverkas. Detta kommer studeras utifrån frågeställningarna ”Hur påverkar en medveten minskning av konsumtion individens självuppfattning och identitet i förhållande till samhällets konsumtionsnormer?” och “Vilka sociala och kulturella effekter upplever individer som minskar sin konsumtion med avsikt, och hur påverkar detta relationer inom individens närmaste krets?” Tidigare forskning har intresserat sig för att förstå varför individer ändrar sitt konsumtionsbeteende. Även det sociala motståndet från samhälle och omgivning har varit ett vida forskningsområde. Ett betydande fokus har även varit att studera konsumtionsmönster ur ett hållbarhetsperspektiv, där forskningen identifierar utmaningar och hur dagens samhälle. Denna studie avser bidra med en ingående förståelse för hur medveten konsumtionsminskning påverkar individens livsaspekter och relationer, vilket kan ha långtgående implikationer för vår förståelse av samhällets föränderliga konsumtionsmönster. Studiens teoretiska ramverk består av Emilé Durkheims sociala tvång bestående av det normativa tvånget, det kulturella tvånget, det materiella tvånget och det strukturella tvånget. I kombination med detta tillämpas även Robert K Mertons samhälleliga spänningar, taget från hans strainteori. Studien baseras på kvalitativa semistrukturerade intervjuer, där vi studerar 8 individers upplevda effekter av konsumtionsminskningar. Resultatet tyder på att en minskning av konsumtion stärker individens egenmakt och främjar självreflektion. Genom minskad betoning på yttre faktorer, formar individer sin självuppfattning bortom materialism. Trots att deras konsumtionsminskning bryter mot normer, möts de av nyfikenhet. Dessa individer tycks agera som agenter för normativ förändring genom att öka medvetenheten om konsumtionens påverkan och främjar en omvandling mot ett mer hållbart levnadssätt.
7

Treatment of process water at Dense Media Separation (DMS) Powders Industry using selected membrane processes

Mosia, Mmankaeya Elsie 07 1900 (has links)
M. Tech., (Faculty of Applied and Computer Science), Vaal University of Technology / There is huge concern in the mining and industries to manage wastewater prior to discharge into the environment. It is generally cheaper and cost reducing for industries to treat its own wastewater before discharging to the local authority sewer. Dense Media Separation (DMS) Powders Company produces milled and atoms ferro-silicon by pyro-metallurgical process. DMS Powders uses municipal water for all processes taking place in the plants. The water used during the processes of milled and atom ferrosilicon powder is discharged into the environment without being treated. By treating this process wastewater before discharging will result in reducing the water consumption by recycling and the penalty costs for polluting the environment. The primary objective of this study is to find suitable method for treatment of DMS Powders’ process water using selected membrane processes. Membrane processes are better choice compared to traditional physical/chemical treatment processes, due to their advantages of approving water quality, no phase change, no chemical addition and simple operation. Two commercial membranes namely; NF-, and SW30HR are used in the treatment of DMS Powders process water. These membranes were purchased from (Dow/Filmtec) Manufacturing Company (Pty) situated in South Africa. Membranes were characterised by Scanning Electron Microscopy (SEM), Thermo Gravimetric Analysis (TGA), Differential Thermal Analysis (DTA) and Fourie Transform Infrared (FTIR) instruments. For synthetic water three membranes (NF- , NF90, and SW30HR) are investigated for the study. The fluxibility indicated that NF- membrane has higher flux compared to NF90 and SW30HR membranes. All the three membranes were very good in terms of rejection on single salts. Fouling was studied on DMS Powders process water. Concentration polarization was formed on NF- and SW30HR membranes investigations on selected membranes conclude that NF- membrane will be the suitable membrane for treatment of DMS Powders process water because of its high fluxibility and rejection. Discharged effluent of DMS Powders could comply with the legislature and environmental pollution could be minimised. The study revealed that fouling does occur during treatment of process water. SW30HR showed that M9 Plant had more fouling for M9 samples than other Plants (M8A and M8B). It was because of higher concentrations in suspended solids.or M8A, M8B and M9 process water.
8

Projeto de um edif?cio para fins educacionais com foco na racionaliza??o do consumo de ?gua

Dantas, Petterson Michel 30 March 2012 (has links)
Made available in DSpace on 2014-12-17T13:57:09Z (GMT). No. of bitstreams: 1 PettersonMD_DISSERT_CAPA_A_CAP 5.pdf: 5028919 bytes, checksum: f9b57610ba8a72ded1c66182f206125f (MD5) Previous issue date: 2012-03-30 / The urban growth without the prior infrastructure has caused many environmental impacts such as the damage to quality of the water resources in the cities. Along with natural scarcity in some regions, this is one of the factors that limit the availability of drinking water. As a result, the conservation of drinking water is becoming one of the major concerns in sustainable architectural projects. Within this context, this dissertation proposes to develop the design of an educational building focusing on water consumption rationalization. The proposed project is located in UFRN Campus at Currais Novos, an area of warm and dry climate and low rainfall. The proposal seeks to integrate ways to reduce water consumption o to architecture, in order to exploit the advantages and savings. After quantifying the benefits achieved, it was concluded that it is possible to reduce significantly the drinking water consumption in educational buildings in universities using three principles: reduction the water consumption at the point of use, replacement of the water source and internal recycling. Calculations and simulations indicated that the proposed building may have water consumption up to 56% lower than if it would be provided by conventional facilities. Rationalization of water consumption brings direct and indirect benefits, with influences on the environmental, social and economic fields / O crescimento urbano sem a infraestrutura pr?via tem provocado diversos impactos ambientais, como o comprometimento da qualidade das reservas h?dricas nas cidades. Juntamente com a escassez natural em certas regi?es, este ? um dos fatores que limitam a disponibilidade de ?gua para consumo. Em fun??o disso, a conserva??o da ?gua pot?vel vem se tornando uma das principais preocupa??es nos projetos arquitet?nicos sustent?veis. Dentro deste contexto, este trabalho se prop?e a desenvolver um projeto de arquitetura para um edif?cio de ensino superior com foco na racionaliza??o do consumo de ?gua. O projeto proposto situa-se no campus da UFRN no munic?pio de Currais Novos, ?rea de clima quente e seco e de baixa pluviometria. A proposta busca integrar medidas de redu??o do consumo de ?gua ? arquitetura, com a finalidade de explorar quais as vantagens trazidas e a economia alcan?ada. Ap?s a quantifica??o de benef?cios das medidas adotadas, constatouse que ? poss?vel reduzir significantemente o consumo de ?gua pot?vel nos edif?cios educacionais em universidades utilizando-se tr?s princ?pios: redu??o do consumo de ?gua no ponto de utiliza??o, substitui??o da fonte de ?gua e reciclagem interna. Os c?lculos e simula??es realizadas indicaram que a edifica??o proposta pode ter um consumo at? 56% menor do que se fosse provida por instala??es hidrossanit?rias convencionais. A racionaliza??o do consumo de ?gua traz benef?cios diretos e indiretos, com desdobramentos no campo ambiental, social e econ?mico
9

Retrofitting to lower energy consumption: comparing two commercial buildings in Sandton, Johannesburg

Thovhakale, Takalani Bridget 20 August 2012 (has links)
M.Sc. / This study compares the electricity consumption of two buildings, of similar architectural design, in Simba Office Park, Sandton, in Johannesburg. One of the buildings (Block AB) has not been retrofitted for energy efficiency, whilst the other building (Block C) is a retrofitted building. The hypothesis postulates that the retrofitted building would use less energy than the non-retrofitted one. The research methodology employed has been used internationally, as in the case reported by Levine et al. (1996), who did a study in the United States of America on retrofitting for achieving energy efficiency. Dong et al. (2005) investigated the energy savings due to the retrofitting of old Singaporean commercial office buildings. In this case, six buildings were compared before and after retrofitting, using utility bill and weather data. There have also been similar studies in China (Xu et al, 2006) and Budapest (Urge-Vorsatz & Novikova, 2008). The Budapest study also unpacked the cost of retrofitting. Using methods advocated by Probst (2004), Yalcintas (2008) and Yalcintas & Kaya (2009) for collecting data on floor space, building parameters and design, this study also collected electricity consumption data based on meter readings for the same blocks over the period March 2009 to April 2010. The retrofitting measures were documented and the associated costs noted. Interviews were conducted with key personnel such as the Central Energy Fund (CEF) House executives, the site electrical engineer, the developer, and Simba Office Park managers. Block AB had the least number of energy-efficient installations. Block C was found to be fully retrofitted, at a cost of more than R4 million. However, the energy management system, required to manage and monitor energy use, was only fully installed by November 2009. The results of this study are significant. It was found that energy consumption for Block C far exceeded that for Block AB. Thus, in this case, retrofitting did not reduce electricity consumption. The results demonstrate that in order to fully understand energy use, data collection and analysis must be ongoing. This verifies the findings of Ali (2008), Armstrong (2009) and Yalcintas & Kaya (2009) who found that we need to shift from managing buildings to managing energy use and assess and verify any recorded savings to ensure energy conservation. Computer-based building management systems play a major role in such management. Such a system was only partially in use in Block C for the duration of the study period. Thus, another finding was that the energy management system needs to be fully operational in real time, or else energy efficiencies cannot be achieved and data sets will be incomplete. This conclusion reflects the findings of Hirst (1980).
10

Implantação de um programa de uso racional de água na universidade federal de goiás estudo de caso edifício da reitoria / Proposal for implementation of the ongoing program of water conservation at Federal University of Goias- Case Study of the rectory building

GOMES, Marcelus Isaac Lemos 01 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:46Z (GMT). No. of bitstreams: 1 DISSERTACAO-07122011.pdf: 2360307 bytes, checksum: 56a7b9d04ed9b12f456d662b2d4e6cb4 (MD5) Previous issue date: 2011-09-01 / The water scarcity has led to changes in position of economic environmental and political issues besides trying to seek new sources of water located at further distances in places more distant. That is to reduce the amount of water needed by, urban population without compromising the quality of activities. This work had the objective to establish a water conservation program, initiated by the implementation of programs for the Rational Use of Water in the building of the Rectory of the Federal University of Goiás, in the city of Goiania. The building selected for the development of a Case Study is used for administrative activities. It comprises two floors, with total built up area of 2,013.84 m2, which was chosen because it showed characteristics that allowed the installation of water meter, for monitoring the daily consumption, and the registration of all points of water consumption, as well as the classification of user categories (including fixed and transitory people). The methodology used considered initially an evaluation and a diagnostic of the building selected for the study. In the sequence a plan was developed and the proposed actions to help in the reduction in water usage was later implemented. Finally, the management of the actions to keep rational usage of water took place including daily monitoring. Based on the analysis of the collected data an economic analysis was carry out to quantify the economic benefits achieved. The consumption data were collected over a period of 240 days, including 120 days before and 120 days after the implementation of water saving measures. The collected data allowed an analysis of the potential for reducing the monthly consumption of water, which in this case was around 30%. The economic analysis showed that the amount invested, including equipment and manpower, would be paid in approximately 20 months, considering average rate of the capital return equal to 0.75% per month. / A escassez da água levou a mudança de postura nos ambientes econômicos, ambientais e políticos, não tratando apenas de buscar novas fontes de água em locais cada vez mais distantes. Trata-se de reduzir a quantidade de água necessária pelas populações, mas sem comprometer a qualidade das atividades desenvolvidas. O presente estudo teve com objetivo a implantação de um programa de conservação da água, iniciado pela implementação de Programas de Uso Racional da Água no prédio da Reitoria da Universidade Federal de Goiás, em Goiânia. A edificação escolhida para o desenvolvimento de um caso de estudo, é utilizada para atividades administrativas, é constituída por dois pavimentos com área total construída de 2.013,84 m2, sendo apropriada para o estudo por apresentar características que permitiram a instalação de hidrômetro, para o monitoramento do consumo diário, e o cadastramento de todos os pontos de consumo de água, bem como a classificação dos tipos de usuários (fixos e flutuantes). A metodologia utilizada contemplou inicialmente uma avaliação e diagnostico da edificação escolhida. Em seguida foi elaborado um plano e posteriormente implantadas medidas que auxiliaram a redução do consumo. Finalmente foi realizado o gerenciamento das ações visando à manutenção da redução alcançada, que incluiu o monitoramento diário. Com base nos dados obtidos foi realizada uma analise econômica para quantificar os benefícios financeiros alcançados. Os dados de consumo foram coletados durante um período de 240 dias, sendo 120 antes e 120 dias após a implantação das medidas economizadoras de água. Os dados coletados permitiram uma análise do potencial de redução do consumo mensal de água, que neste caso foi da ordem de 30%. A análise econômica mostrou que o valor investido, incluindo equipamentos e mão-de-obra, seriam pagos em aproximadamente 20 meses, considerando uma taxa media de remuneração do capital de 0,75% ao mês.

Page generated in 0.556 seconds