• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1556
  • 25
  • 22
  • 22
  • 18
  • 15
  • 15
  • 13
  • 7
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 1607
  • 775
  • 300
  • 284
  • 229
  • 181
  • 169
  • 165
  • 149
  • 137
  • 135
  • 124
  • 124
  • 110
  • 103
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Bioaerossóis na indústria farmacêutica / Bioareorols in the pharmaceutical industry

Guilherme Neves Ferreira 27 April 2009 (has links)
Este estudo teve como finalidade, testar uma barreira contra a contaminação microbiológica em placas de contato, utilizadas em monitoramento de salas limpas para fabricação de produtos farmacêuticos estéreis. Durante o ano de 2007, foram realizados testes de contato com a utilização da mencionada barreira, e os resultados foram comparados com dados dos anos de, 2004, 2005 e 2006, quando a barreira não foi utilizada. Os ambientes utilizados para os testes foram duas salas limpas de uma planta farmacêutica localizada no Rio de Janeiro. Nos mencionados ambientes é necessário o uso de uma vestimenta especial, de forma a evitar que partículas do corpo dos operadores, bactérias e fungos, migrem para a superfície externa do uniforme e coloquem em risco a esterilidade dos produtos. Sendo assim, foi proposta a colocação de uma camiseta diretamente sobre a pele do operador durante todo o ano de 2007 de forma a evitar ou reduzir a possibilidade de migração dessas partículas; e os resultados foram comparados com os anos de 2004, 2005 e 2006, quando a camiseta não foi usada. Os testes demonstraram que houve uma redução de cerca de 50% na ocorrência de placas contaminadas. Com relação ao número total de colônias formadas, a redução foi de 75% na comparação com os anos de 2004 e 2005 e de 50% com relação ao ano de 2006 / This study had as objective to test a barrier against microbiological contamination in contact plates that are used in sterile pharmaceutical products clean rooms monitoring. During 2007 the tests were performed and compared with data from, 2004, 2005 and 2006, when the mentioned barrier was not used. The test environments were two clean rooms from a pharmaceutical plant located at Rio de Janeiro. In the mentioned environments the use of special garments is necessary for avoiding that particles from operators bodies, bacteria and most remain in contact with the room environment, adding risk to the sterilized products. So, it was proposed the use of undershirt between the garment and the operator skin for reducing the contact plates contamination during the regular rooms monitoring. This undershirt was used during 2007 and the results were compared with the samples of 2004, 2005 and 2006 when the undershirt was not used. The results demonstrated that it was obtained a reduction of about 50% in relation to contaminated plates. In relation to the total number of colonies the reduction was 75% in comparison with 2004 and 2005, and 50% in comparison with 2006
102

Análise do colapso de um solo compactado devido à inundação e à interação solo-líquido contaminante

Motta, Eduarda de Queiroz January 2006 (has links)
Made available in DSpace on 2014-06-12T17:39:46Z (GMT). No. of bitstreams: 2 arquivo6140_1.pdf: 2044388 bytes, checksum: 86bd7fe8693a6129c4245c65737df23d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O comportamento de colapso de um solo compactado, devido à inundação com diferentes líquidos, é analisado atra´ves de ensaios de laboratório. O solo é uma Areia Amarelo-Ac]vermelhada do Município de Petrolândia, situado na região Semi-àrida do Estado de Pernambuco, a 520 Km do Recife. O solo foi coletado entre profundidades de 1,0 e 2,2 m, onde geralmente estão assentes as fundações rasas, e foi compactado estaticamente com peso específico aparente seco de campo e máximo da umidade natural ótima, respctivamente. O colapso foi induzido através da inundação das amostras com Esgoto Bruto; soluções preparadas a base de substâncias que compõem as àguas Servidas (àgua Sanitária, Detergente Liquido, Sabão em Pó e òleo de Solja; Chorume; e àgua Destilada, que serviu como parâmetro comparativo entre líquidos utilizados. No programa de investigação geo~écnica em laboratório, realizaram-se ensaios de caracterização física do solo natural; ensaios endométricos, simples e duplos; ensaios de caracterização química do solo, antes e após inundação com diferentes líquidos e ensaios físico-químicos dos líquidos utilizados para inundação nos ensaios edométrico. Analisam-se as influências de alguns fatores que provocam e atuam no colapso, como: o peso específico aparente seco e teor de umidade inicial; tensão vertical de inundação; e interação solo-líquido percolante, através das características físico-químicas dos líquidos utilizados. Conclui-se que a magnitude do colapso e do comportamento de compressibilidade do solo depende do estado tensional do solo (tensão aplicada, estrutura e variação de teor de umidade) e da interação físico-química entre solo e líquido de inundação. Constata-se a influência da tensão superficial dos líquidos no tempo da sua interação com o solo; e verificam-se, nestes solo, a tendência a Potenciais de Colapso mais altos para líquidos de pH mais alcalinos e a leve tendência a Potenciais de Colapso mais altos para líquido de inundação com maisores condutividades. No entanto, deve-se analisar o conjunto de fatores que influenciam no comportamento colapso do colo, e não atibuí-lo apenas a um fator isolado
103

Acúmulo de cádmio, crômio e níquel e isolamento de micro-organismos potenciais para biorremediação em áreas agrícolas /

Minari, Guilherme Deomedesse. January 2016 (has links)
Orientador: Lucia Maria Carareto Alves / Coorientador: Luciana Maria Saran / Banca: Mariana Carina Frigieri / Banca: David Luciano Rosalen / Resumo: A contaminação do solo pode ser decorrente do descarte inadequado de substâncias com potencial poluente ou do uso agrícola prolongado com aplicação de materiais corretivos de acidez, fertilizantes e defensivos. O objetivo deste estudo foi avaliar a distribuição espacial de cádmio (Cd), cromo (Cr) e níquel (Ni) em Latossolo sob plantio direto, convencional e convencional com aplicação de lodo de esgoto, em áreas com exploração agrícola há mais de 80 anos. As concentrações dos metais em 422 amostras de solo foram mensuradas por espectroscopia de absorção atômica com chama ar-acetileno, sendo os extratos obtidos por extração com HNO3, H2O2 e HCl em sistema aberto (USEPA-3050B). As variáveis pH e matéria orgânica também foram determinadas. Os mapas de distribuição espacial foram elaborados a partir do software Spring v. 5.2.7 e auxiliaram na visualização da dispersão dos metais na área de estudo, indicando níveis de contaminação. A análise estatística multivariada por componentes principais diferenciou as amostras de solo de mata nativa das que estão sob atividade agrícola, apontando a uma mesma fonte de contaminação para Cr e Ni, como também para a correlação da matéria orgânica com Cd. Conclui-se que a área estudada apresenta contaminação, em larga escala, por Cd e Cr, e contaminações pontuais por Ni, estando alguns valores dentro da faixa de intervenção / Abstract: Soil contamination may result from inappropriate use of substances with pollution potential or from the prolonged agricultural use with application of acidity corrective materials, fertilizers and pesticides. The aim of this work was to evaluate the spatial distribution of cadmium (Cd), chromium (Cr) and nickel (Ni) in latosol under no tillage, conventional tillage and conventional with sewage sludge application, in agricultural exploration areas for over 80 years. Metals concentration in 422 soil samples were measured by atomic absorption spectroscopy with acetylene-air flame, obtaining the extracts by extraction with HNO3, H2O2 e HCl in open system (USEPA-3050B). The variables pH and organic matter were obtained. Maps of spacial distribution were elaborated by software Spring v. 5.2.7 and assisted in the visualization of the metals dispersion in the study area, indicating contamination levels. The statistical multivariate by main components differentiated the native forest soil samples from those under agricultural activity, pointing to a same contamination source to Cr and Ni, and to the organic matter correlation to Cd as well. It can be concluded that the studied area presents contamination in large scale by Cd and Cr and pontual contamination by Ni, being some of the values into the intervention group / Mestre
104

Caracterização dos aqüíferos em meio cristalino da porção oeste da Bacia do Alto Tietê / Characterization of the aquifers in the crystalline environment on the west plot of the Alto Tiete Basin.

Ivanety Pereira Santos de Jesus 22 December 2005 (has links)
A área de estudo situa-se na Bacia do Alto Tietê a jusante da cidade de São Paulo, entre as coordenadas UTM 7420 e 7382 km Latitude - 298 e 328 km Longitude perfazendo uma área de 1.140 km2. O trabalho teve como objetivo caracterizar os aqüíferos fissurais da região, correlacionando os parâmetros hidrogeológicos com diversos fatores que condicionam à produtividade. A área abrange compartimentos geológicos distintos constituídos por rochas supracrustais de baixo a médio grau metamórfico, intrudidas por suítes graníticas. Sobre estas rochas ocorrem sedimentos da Bacia de São Paulo e os aluviões de planícies. A metodologia empregada neste estudo envolveu a compilação e integração geológica, incluindo análise dos mapas geológicos existentes e trabalhos de campo, análise de padrões de lineamentos e fraturamento, incluindo parâmetros como conectividade, densidade, distância e comprimento . A caracterização hidrogeológica envolveu o cadastramento de 317 poços, os quais foram correlacionados com os diversos parâmetros lito lógicos, estruturais e hidrogeológicos relacionados à produção de águas. A análise estatística mostrou, de modo geral, que não existe correlação significativa entre os parâmetros e a produtividade. Entretanto, de acordo com os resultados, estabeleceu-se uma ordenação de produtividade conforme os tipos litológicos: Calcários > sedimentos > filitos > (micaxistos+quartzitos) > (granitos+gnaisses). Conforme o contexto geológico na área, neste trabalho foram propostos três sistemas hidrogeológicos que são: Sistema Aquífero Granitóide (granitos e gnaisses); Sistema Aquífero Metassedimentar (filitos, micaxistos, quartzitos e calcários); e Sistema Aquífero Sedimentar (lamitos argilosos/arenosos e areias/cascalhos). Estes sistemas distinguem-se pela associação litológica, o padrão estrutural, a produtividade dos poços e pela fácies hidroquímicas. Os parâmetros hidráulicos foram avaliados por meio dos programas AQFIS3, AQTSOLVE e PUMPEST. As transmissividades (T) calculadas compreendem de forma decrescente as litologias de Quartzitos> Filitos> Micaxistos> Granitos> Calcários> Gnaisses. Avaliou-se a análise química de 44 amostragens d\'água utilizando os parâmetros relativos aos ânions (F-, Cl-, Br-, NO3-, HPO4-, SO4-, HCO3-; cátions (Na, Mg, K, Ca); além da: condutividade elétrica, Dureza Total, pH, Eh, T, Sílica e Oxigênio Dissolvido. A caracterização química das águas subterrâneas da área permitiu identificar a presença de três fácies dominante: bicarbonatadas cálcicas, sódicas e potássica, sulfatadas cloretadas. A interpretação da modelação hidrogeoquímica com uso do programa PHREEQE e NETPATH, possibilitou que se estabelecesse a evolução da água apresentando quase sempre subsaturada e por vezes sobressaturadas ou em equilíbrio com relação aos diversos minerais pertencentes às rochas existentes. / An area of 1140 km2 in the Alto Tietê basin, downstream from the city of São Paulo, between UTM coordinates 7420/7382 km South and 298/328 km West, was studied in order to characterize the fissural aquifers of the region and correlate hydrogeological parameters with diverse other factors conditioning productivity. The area includes geological compartments made up of Precambrian supracrustal rocks of low to medium metamorphic grade, intruded by granitic suites. Upon these rocks, occur Tertiary sedimentary rocks of the São Paulo Basin and alluvial plains. This study involved geological compilation and integration, with analysis of geological maps as well as field work and analysis of fracture patterns (orientation, connectivity, density, distance and length), which were correlated with the production of the wells assessed in each lithology. A statistical analysis showed that, in general, there is no significant correlation between the parameters and productivity. Hydrogeological characterization of data from 317 wells based on parameters related to water production allowed the ordering of productivity as follows: Limestones > sediments > phyllites > micas-chists+quartzites, granites+gneisses. According to the geological contexts in the area, three hydrogeological systems are proposed: the Granitoid (granites and gneisses) aquifer system; the Metasedimentary (phyllites, mica-schists, quartzites and limestones) aquifer; and system the Sedimentary (argillaceons/arenaceous mudstones and sand/graved). These systems may be distinguished by their lithological associations, structural patterns, well productivitys and hydrochemical facies. Hydraulic parameters were appraised by means of the programs AQFIS3, AQTSOLVE and PUMPEST. The calculated transmissivibility (T) decreases as follows: quartzites > phyllites > mica-schists > granites > limestones > gneisses. The chemical analyses of 44 samples of water were evaluated using the relative parameters related to the anions F-, Cl-, Br-, NO3-, HPO4-, SO4- and HCO3- and the cations Na, Mg, K and Ca, as well as electrical conducti vity parameters total durablity pH, Eh, T, Silica and Dissolved Oxygen. The chemical characterization of the groundwaters of the area allowed the identification of three dominant facies: calcium bicarbonate; sodic potassic; and sulfate chloreted. The interpretation of the hydrogeochemical modeling using the PHREEQE and NETPATH programs revealed that the water is undersaturated most of the time but sometimes oversaturated or in equilibrium with respect to minerals in the existing rocks.
105

Número mais provável (nmp) de coliformes fecais e estreptococos fecais e isolamento de bactérias do gênero Salmonella e Clostridium perfringens de água de escaldamento em matadouro de suínos, São Paulo, 1981-1982 / Most likely number (nmp) of fecal coliforms and fecal streptococci and isolation of bacteria of the genus Salmonella and Clostridium perfringens from scalding water in swine slaughterhouse, São Paulo, 1981-1982

Yolanda Mercedes Silva Camps 21 February 1985 (has links)
Foram determinados os NMP/100 ml de bactérias coliformes fecais e estreptococos fecais e foi realizada a pesquisa de bactérias do gênero Salmonella e de C. perfringens, em águas de escaldamento de um matadouro de suínos, situado no Município de Carapicuíba, Estado de São Paulo, Brasil. Foram registrados a temperatura e o pH de cada amostra por serem estes, fatores fundamentais para a sobrevivência bacteriana. Os NMP/100 ml da amostra variaram de <3 a 4.3 x 10 para coliformes fecais e de 2.3 x 10 a 1.1 x 10 para estreptococos fecais. Isolaram-se bactérias do genero Salmonella de 6 por cento das 50 amostras estudadas e Clostridium perfringens tipo A de 40 por cento das 25 amostras pesquisadas. Conclui-se que o tanque de escaldamento pode ser uma importante fonte de contaminação da carcaça de suínos, sendo necessário instituir uma legislação, baseada em critérios epidemiológicos, relativa ao processo de abate em geral e sobre o uso do tanque em particular. / Not available
106

Avaliação da ocorrência e do transporte de microrganismos no aqüífero freático do cemitério de Vila Nova Cachoeirinha, município de São Paulo. / Assessment of occurrence and transport of microorganisms in the unconfined aquifer of Vila Nova Cachoeirinha cemetery, city of São Paulo.

Matos, Bolivar Antunes 30 May 2001 (has links)
Este trabalho avaliou a ocorrência e o transporte de microrganismos no aqüífero freático do cemitério de Vila Nova Cachoeirinha, localizado em terrenos pré-cambrianos, zona norte do município de São Paulo. A metodologia aplicada foi dividida em etapas de laboratório e de campo. No laboratório, foram montadas colunas de solo do cemitério. Traçadores químico e biológico foram injetados nas colunas e o seu fluxo monitorado no efluente. Um modelo numérico foi usado para simular o transporte dos traçadores nas colunas. Em campo, foram realizadas investigações a fim de caracterizar o aqüífero freático. A monitoração da qualidade das águas foi realizada para estudar a ocorrência e o transporte de elementos químicos, bactérias e vírus nas águas subterrâneas. No cemitério, o embasamento está a cerca de 9,0 m de profundidade na cota mais baixa e 20,5 m no topo. O nível freático encontra-se entre 4 e mais de 16 m. O solo do cemitério é formado pelo material de alteração das rochas graníticas, de caráter predominantemente argiloso (~43% de argila), pH =5,0, matéria orgânica entre 0,7 e 4,2% e capacidade de troca de cátions entre 10,2 e 109,0 mmolc/kg. A condutividade hidráulica do aqüífero varia de 2,90 x 10-8 a 8,41 x 10-5 m/s. O gradiente hidráulico na porção oeste do cemitério é de aproximadamente 0,07 m/m; considerando o meio homogêneo e isotrópico e uma porosidade efetiva de 2%, a velocidade linear média foi estimada em 8 cm/dia. As amostras de água do aqüífero freático do cemitério de Vila Nova Cachoeirinha apresentaram, principalmente, bactérias heterotróficas (53 x 103 UFC/mL), bactérias proteolíticas (31 NMP/100 mL) e clostrídios sulfito-redutores (45 NMP/100 mL). Também foram encontrados enterovírus e adenovírus nas amostras. As principais fontes de contaminação das águas subterrâneas no cemitério são as sepulturas com menos de um ano, localizadas nas cotas mais baixas, próximas ao nível freático. Nestes locais, é maior a ocorrência de bactérias em geral. Há um grande consumo do oxigênio existente nas águas. As sepulturas ainda provocam um acréscimo na quantidade de sais minerais, aumentando a condutividade elétrica destas águas. Parece haver um aumento na concentração dos íons maiores bicarbonato, cloreto, sódio e cálcio, e dos metais ferro, alumínio, chumbo e zinco nas águas próximas de sepulturas. As bactérias são transportadas poucos metros, diminuindo em concentração com o aumento da distância à fonte de contaminação. Os vírus parecem ter uma mobilidade maior que as bactérias, podendo atingir algumas dezenas de metros no aqüífero freático do cemitério de Vila Nova Cachoeirinha. Os vírus foram transportados, no mínimo, 3,2 m na zona não saturada até alcançar o aqüífero. / This work assessed occurrence and transport of microorganisms in the unconfined aquifer of Vila Nova Cachoeirinha cemetery, located on pre-cambrian terrains at the northern zone of the city of São Paulo The applied methodology was divided in laboratory and field stages. In the lab, cemetery soil columns were designed; chemical and biological tracers were injected in the columns and the effluent was monitored. A numerical model was used to simulate the tracers’ transport through the columns. In the field, several investigations were done to characterize the unconfined aquifer; water quality was monitored to study occurrence and transport of chemicals, bacteria and viruses in groundwater. In Vila Nova Cachoeirinha cemetery, the depth to the bedrock is about 9.0 m at small elevation areas and 20.5 m at the top of the hill. The depth to the water table varies from 4 to over 16 m. The soil is formed by the weathered material of the granite rocks, clay content of 43%, pH = 5,0, cation exchange capacity between 10.2 and 109.0 mmolc/kg. The hydraulic conductivity of the aquifer varies from 2.90 x 10-8 to 8.41 x 10-5 m/s. The hydraulic gradient at the western part of the study area is about 0.07 m/m; considering a homogeneous and isotropic medium and an effective porosity of 2%, the average linear velocity was estimated in 8 cm/day. The water samples of the unconfined aquifer of Vila Nova Cachoeirinha cemetery presented, mainly, heterotrophic bacteria (53 x 103 UFC/mL), proteolitic bacteria (31 NMP/100 mL) and clostridium perfringes (45 NMP/100 mL). We have also found enterovirus and adenovirus in groundwater. The main sources of contamination are the within-a-year-graves located at the low elevation areas, close to the water table. At these sites, the occurrence of bacteria is greater and there is a greater consumption of oxygen in the water due to oxidation of organic matter. Moreover, the graves cause an increase in salts and electrical conductivity of the groundwater. There seems to be an increase in major ions: hydrogen carbonate, chloride, sodium, calcium; and metals: iron, aluminium, lead and zinc, next to the graves. The bacteria traveled a distance of a few meters, decreasing in concentration with increasing distance to the graves. The viruses seem to be more mobile than bacteria, they traveled distances of tens of meters at the Vila Nova Cachoeirinha cemetery. The viruses were transported at least 3.2 m through the unsaturated zone before reaching the unconfined aquifer.
107

Poderá Nassarius Reticulatus (L.) ser usado como bioindicador da contaminação por mercúrio?

Pimenta, Joana Maria Frias Medeiros de January 2007 (has links)
Tese de mestrado. Engenharia do Ambiente (Ramo de Gestão e Tratamento de Resíduos Industriais). Faculdade de Engenharia. Universidade do Porto. 2007
108

Migração de compostos voláteis através de diferentes vedantes e embalagem

Pimenta, Maria de Fátima Moreira January 2009 (has links)
Estágio realizado na Amorim & Irmãos, S.A. - Investigação & Desenvolvimento e orientado pelo Doutor Miguel Cabral / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
109

Previsão do tempo de remediação de solos contaminados usando a extracção de vapor

Albergaria, José Tomás Veiga Soares de January 2010 (has links)
Tese de doutoramento. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto, Departamento de Engenharia Química. Instituto Superior de Engenharia do Porto. 2010
110

Amostragem de sólidos em espectrometria de absorção atômica de fonte contínua com alta resolução: análise de plantas medicinais

Rêgo, Jardes Figuerêdo do [UNESP] 19 November 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-11-19Bitstream added on 2014-08-13T18:01:04Z : No. of bitstreams: 1 000747370_20141231.pdf: 717783 bytes, checksum: c4b4e78a50f2c554cb1d9f949caafee2 (MD5) Bitstreams deleted on 2015-01-05T11:00:46Z: 000747370_20141231.pdf,Bitstream added on 2015-01-05T11:01:46Z : No. of bitstreams: 1 000747370.pdf: 13604795 bytes, checksum: 1cc506830b013969ae968ef0b7210106 (MD5) / O uso de fitoterápicos tem crescido consideravelmente nos últimos anos. Entretanto, o consumo de produtos derivados de plantas medicinais não está isento de riscos. Além do princípio ativo algumas espécies vegetais podem apresentar em sua composição química substâncias tóxicas (orgânicas ou inorgânicas) que podem causar sérios danos à saúde quando ingeridas. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de métodos analíticos visando a determinação de As, Cd, Co, Pb, Se e Sn em plantas medicinais empregando a espectrometria de absorção atômica de fonte contínua com alta resolução em forno de grafite com amostragem direta de sólidos (SS HR-CS GFAAS). O emprego de modificadores químicos permitiu calibração em meio aquoso para determinação dos analitos. A utilização de uma etapa de pirólise extra assistida por ar a 600 °C permitiu eliminar resíduos carbonáceos e eliminar os sinais de fundo. Para determinação de As, Co, Se e Sn foram observadas interferências espectrais causadas por moléculas diatômicas de PO e SiO. Nestes casos, o emprego do algoritmo dos mínimos quadrados (LSBC) corrigiu o fundo; entretanto, para a determinação de As observou-se interferências espectrais provocadas por linhas atômicas de Al que somente foram corrigidas utilizando algoritmo de correção de fundo interativa (IBC). Os limites de detecção foram 28,7 ng g-1 (As), 0,15 ng g-1 (Cd), 3,2 ng g-1 (Co), 7,3 ng g-1 (Pb), 40,1 ng g-1 (Se) e 24,5 ng g-1 (Sn). A exatidão dos métodos foi avaliada através da análise de materiais de referência certificados de plantas, cujos valores foram concordantes com os certificados ao nível de 95 % (test t). Os estudos de homogeneidade foram conduzidos visando determinar as massas mínimas e a homogeneidade após moagem com moinho criogênico e moinho de facas. A melhor precisão e exatidão foi obtida a partir da análise de massas maiores que 0,2 mg de amostra... / Phytotherapy has increased considerably during the last years. However, besides active compounds, products derived from medicinal plants may contain hazardous organic compounds or toxic metals. Thus, the goal of this work was to develop methods to determine As, Cd, Co, Pb, Se and Sn in medicinal plants by high-resolution continuum source atomic absorption spectrometry using solid sampling. The use of chemical modifiers allowed the determination of the analytes of interest using calibration with aqueous standard solutions. An additional air-assisted pyrolysis step at 600 °C was useful to remove carbonaceous residues and eliminate background signal. Spectral interferences due to structured background caused by diatomic molecules (PO and SiO) were observed on the analytical lines of As, Cd, Co and Sn. In this case, interferences were removed using least squares background correction algorithm (LSBC). In addition, interactive correction background algorithm (IBC) was used to remove spectral interferences caused by Al lines on the analytical line of As. Limits of detection were 28.7 ng g-1 (As), 0.15 ng g-1 (Cd), 3.2 ng g-1 (Co), 7.3 ng g-1 (Pb), 40.1 ng g-1 (Se) and 24.5 ng g-1 (Sn). Micro-homogeneity studies were performed after using knife or cryogenic mills in order to establish minimal sample mass and homogeneity. Most accurate and precise results were obtained for sample masses above 0.2 mg for samples ground using knife mill with 30 mesh sieve or cryogenic mill. Accuracy and precision were evaluated by analyzing plant certified reference materials and results were in agreement with certified values at a 95% confidence level (t test). The proposed methods were applied for the determination of analytes in eighteen medicinal plant samples. The concentration ranged from 3.2 to 287.2 ng g-1 (Cd), 14.7 to 1195.7 ng g-1 (Co), 124.2 to 1946.1 ng g-1 (Pb) and 142.8 to 342.6 ng g-1 (Sn). Results were in agreement at a 95% confidence level...

Page generated in 0.0717 seconds