1 |
Estudo das alterações renais induzidas pelos meios de contraste de alta e baixa osmolalidade / Study of renal disorders induced by contrast media of high and low osmolalityLima, Erika Gondim Gurgel Ramalho January 2011 (has links)
LIMA, Erika Gondim Gurgel Ramalho. Estudo das alterações renais induzidas pelos meios de contraste de alta e baixa osmolalidade. 2011. 92 f. Dissertação (Mestrado em Farmacologia) - Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2012-09-03T12:29:02Z
No. of bitstreams: 1
2011_dis_eggrlima.pdf: 3458339 bytes, checksum: 48ca994786dbb96eff552a77d38eb834 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-09-03T14:12:46Z (GMT) No. of bitstreams: 1
2011_dis_eggrlima.pdf: 3458339 bytes, checksum: 48ca994786dbb96eff552a77d38eb834 (MD5) / Made available in DSpace on 2012-09-03T14:12:46Z (GMT). No. of bitstreams: 1
2011_dis_eggrlima.pdf: 3458339 bytes, checksum: 48ca994786dbb96eff552a77d38eb834 (MD5)
Previous issue date: 2011 / Iodinated contrast media (ICM) is important in current medical practice during diagnostic and therapeutic interventions. Nephropathy induced by contrast medium (CMIN) is the third iatrogenic cause of acute renal failure in hospitalized patients. The objective of this work was to study the renal effects of contrast media meglumine and ioxitalamato Iobitridol and may contribute to the discovery of pharmacological tools and / or elucidate the mechanisms of nephrotoxicity. The effects of contrast media ioado (MCI) were evaluated on male Wistar rats housed in metabolic cages, every 24 hours for a period of 72 hours after the administration of intravenous contrast. In the control group was administered saline, while groups received ioxitalamato meglumine (high osmolality) and Iobitridol (low osmolality). We analyzed daily urine output, water intake and food. Renal function was assessed by perfusion of isolated rat kidney after 72 hours of administration of the MCI , where perfusion was performed with Krebs Henseleit modified 6g% bovine albumin. Data were compared by ANOVA and Bonferroni test, with significance of p <0.05. The water intake increased in the group treated with high-osmolality contrast (mL/24hs 26.00 ± 2.00) compared to the control group (19.00 ± 1.175 mL/24hs) at the time of 24 hours. Diuresis contrast the group treated with high osmolality (6.84 ± 0.767 mL/24hs), at 24 hours, increased significantly when compared to controls (3.57 ± 0.696 mL/24hs). Perfused isolated rat kidney, we observed an increase in perfusion pressure (PP) in the groups receiving high contrast (98.40 ± 2.467 mmHg *, p <0.05) and low osmolality (126.8 ± 0.936 * mmHg, p <0.05) when compared to the control group (89.13 ± 0.818 mmHg) at the time of 30 minutes. The glomerular filtration rate was reduced in the groups of high osmolality (0.297 ± 0.039 mm.g-1.min-1 **, p <0.05) and low osmolality (0.390 ± 0.053 mm.g-1.min-1 ** p <0.05) when compared with controls (0.741 ± 0.042 mm.g-1.min-1) at time 120 minutes. Regarding the transport of electrolytes was observed for the percentage of tubular transport of chloride in the group of low osmolality (72.41 ± 0.892% MCI-) compared with control groups (83.68 ± 0.951% MCI-) and high osmolality (79.72 ± 1.335%-TCL), in time of 120 minutes, in relation to the tubular transport of potassium was observed a reduction in high-osmolality group (53.86 ± 5.847% TK +) compared to control groups (79 64 ± TK + 1.710%) and low osmolality (69.34% ± 2.479 TK +) at the time of 120 minutes. Histological analysis kidneys receiving high contrast and low osmolality in time of 72 hours, an intense deposition was observed in all cylindrical tubules both the cortex and spinal cord. The glomeruli showed no deposition. In MDCK cell culture cytotoxicity was evident contrasts of high and low osmolality, with a predominance of apoptosis by flow cytometric evaluation. The results demonstrate that the high contrast and low osmolality induce changes in the metabolism of rats daily and vascular parameters assessed in the kidney and kidney perfusion isolated and have cytotoxic activity on MDCK cells. / Os meios de contraste iodado (MCI) são imprescindíveis na prática médica atual, durante as intervenções diagnósticas e terapêuticas. A nefropatia induzida por meio de contraste (NIMC) é a terceira causa iatrogênica de insuficiência renal aguda em pacientes hospitalizados. O objetivo deste trabalho foi estudar os efeitos renais dos meios de contraste ioxitalamato de meglumina e iobitridol, podendo contribuir para a descoberta de ferramentas farmacológicas e/ou elucidar os mecanismos de nefrotoxicidade. Os efeitos dos meios de contraste ioado (MCI) foram avaliados em ratos Wistar mantidos em gaiolas metabólicas, a cada 24 horas, por um período de até 72 horas após a administração do contraste por via intravenosa. No grupo controle foi administrado solução salina, enquanto os grupos tratados receberam ioxitalamato de meglumina (alta osmolalidade) e iobitridol (baixa osmolalidade). Foram analisadas diariamente diurese, ingesta de água e alimento. A função renal foi avaliada através da perfusão de rim isolado de ratos após 72 horas da administração do MCI, onde a perfusão foi realizada com solução de Krebs Henseleit modificada com 6g% de albumina bovina. Os dados foram comparados através do teste Bonferroni e ANOVA, com significância de p<0,05. A ingesta de água aumentou no grupo tratado com contraste de alta osmolalidade (26,00±2,00) quando comparado ao grupo controle (19,00±1,175) no tempo de 24 horas. A diurese do grupo tratado com contraste de alta osmolalidade (6,84±0,767), no tempo de 24 horas, aumentou significativamente quando comparada ao grupo controle (3,57±0,696). Em perfusão de rim isolado de rato, foi observado aumento da pressão de perfusão (PP) nos grupos que receberam contraste de alta (98,40±2,467) e de baixa osmolalidade (126,8±0,936) quando comparados ao grupo controle (89,13±0,818), no tempo de 30 minutos. O ritmo de filtração glomerular sofreu redução nos grupos de alta osmolalidade (0,297±0,039) e baixa osmolalidade (0,390±0,053), quando comparado ao controle (0,741±0,042), no tempo de 120 minutos. Em relação ao transporte de eletrólitos, foi observado alteração no transporte tubular de cloreto no grupo de baixa osmolalidade (72,41±0,892) quando comparado aos grupos controle (83,68±0,951) e de alta osmolalidade (79,72±1,335), no tempo de 120 minutos; em relação ao transporte tubular de potássio foi evidenciado uma redução no grupo de alta osmolalidade (53,86±5,847) quando comparado aos grupos controle (79,64±1,710) e de baixa osmolalidade (69,34±2,479), no tempo de 120 minutos. Na análise histológica, os rins que receberam contraste de alta e de baixa osmolalidade, no tempo de 72 horas, foi observado uma intensa deposição cilíndrica em todos os túbulos, tanto no córtex quanto na medula. Os glomérulos não apresentaram deposição. Na cultura de células MDCK foi evidenciado citoxocidade dos contrastes de alta e de baixa osmolalidade, com predomínio de apoptose através da avaliação por citometria de fluxo. Estes resultados demonstram que os contrastes de alta e baixa osmolalidade induzem alterações no metabolismo diário dos ratos e nos parâmetros vasculares e renais avaliados na perfusão de rim isolado e possui ação citotóxica sobre as células MDCK.
|
2 |
El contraste en la puesta en escena de Inmunda: choque perceptivo de la fealdadIriarte Uribe, Juan January 2016 (has links)
Magíster en artes mención dirección teatral / Una de las tareas más críticas de un director teatral es la composición escénica, labor que no sólo da cuenta de su poética, sino que también influye en la recepción de los espectadores, sobre todo cuando se contraponen estéticas tan disímiles como lo bello y lo feo en una obra teatral. Es por esta razón que el contraste como elemento perceptivo es clave para construir escenas en el contexto contemporáneo actual. En el presente documento se muestran algunas definiciones del contraste según áreas como la psicología, la plástica, la música, el teatro, etc.); y las estrategias de composición en las que interviene como recurso visual y perceptual: coloración, tratamiento lumínico, actuación, música, entre otras. Se expone una panorámica de la aplicación del contraste en la acción teatral, especialmente la realizada por los directores Tadeusz Kantor y Rodrigo García, quienes han confrontado las normas del teatro tradicional para dar paso a la irrupción de estéticas de la fealdad en la realización escénica. Por este motivo se analiza la existencia histórica en el arte de lo bello y lo feo, en tanto grotesco, monstruoso, ominoso y abyecto. De este modo se articulan las decisiones prácticas para el uso del contraste como herramienta perceptiva en la puesta en escena De Inmunda, pieza teatral que escenifica el impacto de las enfermedades catastróficas en el cuerpo de los pacientes y en las relaciones familiares, develando los paradigmas que existen entre lo bello y lo feo; la salud y la enfermedad; y la vida y la muerte, a través del contraste perceptivo.
|
3 |
Amélioration et évaluation de la qualité des images / Enhancement and evaluation of image qualityCherifi, Daikha 19 December 2014 (has links)
Dans le cadre de cette thèse nous nous sommes intéressés à l’amélioration de la qualité visuelle des images, en rehaussant le contraste des images. Nous avons proposé, tout d’abord, une méthode de rehaussement simple et efficace s’inspirant du système visuel humain. Cette méthode est efficace,quand elle est appliquée aux images naturelles en couleur, ou monochromes. La méthode proposée est ensuite améliorée pour pouvoir rehausser d’autre type d’image comme les images médicale, telles que les images de rétine et l’endoscopie. Par la suite, nous nous sommes aussi intéressés aux rehaussements des images médicales et en particulier aux images de mammographie et nous avons donc proposé une méthode de rehaussement de contraste qui leur est spécifiquement dédiée. Au final,nous nous sommes intéressés à l’évaluation des méthodes de rehaussement proposées et aux différentes approches existantes dans la littérature. La méthode d’évaluation proposée s’appuie sur l’analyse radiale et angulaire du spectre d’énergie de Fourier. La validation de notre méthode de rehaussement de contraste a été faite en utilisant des échantillons d’images de 2 bases et en utilisant un test subjectif pour la comparer à d’autres méthodes de rehaussement. La note subjective finale de MOS, obtenue par la moyenne des notes des observateurs, montre la fiabilité de notre méthode de rehaussement de contraste et son intérêt par comparaison aux autres méthodes classiques. / The aim of this thesis is to propose new methods for image enhancement based on oriented and multi-scale transforms using some perceptual criteria. The first part of the thesis is devoted to the development of a simple and efficient contrast enhancement method inspired from the human visual system. This method is evaluated on a set of natural color and monochrome images. The obtained results are evaluated subjectively and by using objective measures based on energy spectrum analysis and perceptual criteria. The enhancement technique is also extended to some medical images, such as mammography and endoscopy images. A special contrast enhancement method adapted to mammography is then proposed. It is based on a segmentation process using a priori information on the mammography images. The last part of the thesis is devoted to image enhancement evaluation. A critical literature survey of image enhancement evaluation methods is provided. The evaluation method proposed in this thesis is based on the radial and angular analysis of the Fourier powerspectrum. Another perceptual approach is proposed to evaluate the output. This method is based on the analysis of the visibility map computed by using a pyramidal contrast. The evaluation is performed on some samples taken from two databases. Both subjective and objective evaluations demonstrate the efficiency of the proposed image enhancement methods.
|
4 |
Avaliação da dinâmica normal da circulação do meio de contraste em estruturas vasculares nos exames de tomografia computadorizada das artérias coronáriasMorato, Tiago Nóbrega January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Cristiane Mendes (mcristianem@gmail.com) on 2015-07-07T19:15:02Z
No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-07-08T19:08:55Z (GMT) No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Made available in DSpace on 2015-07-08T19:08:55Z (GMT). No. of bitstreams: 1
2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Introdução: O uso de agentes de contraste intravenoso é corriqueiro em pacientes submetidos à tomografia computadorizada (TC) de tórax. Sabe-se que o tempo de trânsito de contraste (TTC) do sítio de injeção até a circulação sistêmica tem relação com o débito cardíaco e pode trazer importantes informações funcionais, pouco estudadas até o momento. Objetivos: Medir o TTC entre o tronco pulmonar e aorta ascendente em exames de TC de artérias coronárias de pacientes saudáveis, definindo padrões de normalidade para estes tempos de circulação. Métodos: Pacientes ambulatoriais sadios encaminhados para realização de TC de artérias coronárias arrolados de forma consecutiva. Os TTC entre o sítio de injeção e a veia cava superior, tronco pulmonar e aorta ascendente foram medidos com base nas imagens de monitorização (bolus tracking). O débito cardíaco foi calculado a partir das imagens da TC pelo método geométrico e correlacionado com os TTC. Resultados: Foram analisados 18 pacientes. O TTC médio entre a artéria pulmonar e a aorta ascendente foi de 6,8 ± 1,6s. Não houve correlação significativa entre o TTC na circulação pulmonar e o débito cardíaco medido pelo método geométrico. Conclusão: O valor de normalidade do TTC entre a artéria pulmonar e aorta ascendente foi estabelecido, servindo de base para avaliação clínica. / Introduction: The use of contrast agents is a common radiological practice in chest tomography (CT) examinations. It’s known that the transit time of the contrast agent (TTC) between the injection site and the systemic circulation is related to the cardiac output and can add important functional information. Nevertheless, there is little information regarding the normal transit times. Objectives: Measure the TTC between main pulmonary artery and ascending aorta in coronary artery CT’s of healthy patients, defining the normality values for such circulatory times. Methods: Healthy ambulatorial patients who underwent coronary artery CT were included. The TTC’s between the injection site and inferior vena cava, main pulmonary artery and ascending aorta were measured using the bolus tracking images. The cardiac output was measured from the CT images using the geometric method. Results: 18 patients were included in the analysis. The mean TTC between the mean pulmonary artery and aorta was 6,8 ± 1,6s. There was no significant correlation between the TTC and cardiac output measured by the geometric method. Conclusion: The normal value for the TTC between main pulmonary artery and ascending aorta was determined, and can be used as a reference for future publications.
|
5 |
Etude des mécanismes d'internalisation hépatique de systèmes moléculaires et nanoparticulaires, agents de contraste pour l'imagerie par résonance magnétique nucléaireColet, Jean-Marie 05 January 1995 (has links)
Les pathologies du foie représentent une des causes les plus fréquentes de mortalité. Ceci provient sans doute de la difficulté de poser le diagnostic à un stade précoce de leur développement malgré les très bonnes performances de l'échographie et de la tomographie de rayons X. On espère que l'IRM dont les résultats spectaculaires dans le diagnostic des tumeurs cérébrales sont aujourd'hui incontestés améliorera la situation. Malheureusement, comme les autres techniques et en dépit de son excellent contraste inhérent, l'IRM se heurte aussi au problème de la mise en évidence des maladies hépatiques. Afin de remédier à cette situation, la recherche s'est orientée vers l'élaboration de produits de contraste spécifiques. La stratégie suivie jusqu'ici est double: d'une part, des complexes d'ions paramagnétiques sont développés pour favoriser leur incorporation par les hépatocytes, et, d'autre part, des nanoparticules superparamagnétiques sont synthétisées afin de cibler les cellules de Kupffer, les macrophages fixes du foie.
|
6 |
Imagerie de l'appendicite aiguë chez l'adulteKeyzer, Caroline 23 November 2009 (has links)
L’appendicite aiguë est la pathologie abdominale aiguë courante et la plus fréquente parmi celles qui nécessitent une intervention chirurgicale rapide. L’imagerie occupe une place croissante dans son diagnostic parce qu’elle tente d’éviter simultanément les appendicectomies inutiles et les perforations appendiculaires compliquées de péritonite tout en recherchant des pathologies alternatives. Si plusieurs techniques d’imagerie sont disponibles – dont la radiographie sans préparation de l’abdomen (dont la performance est faible) et l’imagerie par résonance magnétique (peu disponible, en particulier en urgence) – l’ultrasonographie (US) et la tomodensitométrie (TDM) occupent des positions centrales. Nos études ont investigué la performance de ces dernières, en considérant notamment la réduction de la dose d’irradiation et le recours aux contrastes artificiels. En effet, l’irradiation liée à l’usage de la TDM est à considérer puisque les patients souffrant d’appendicite aiguë sont jeunes (en moyenne 30 ans) tout comme le recours aux contrastes associé à des coûts, de l’inconfort et des risques. Enfin, la performance de ces techniques étant susceptibles d’être influencée par la corpulence des patients et leur quantité de graisse intra-abdominale, l’influence de ces paramètres sur la performance a été évaluée.
A travers quatre études, nous avons montré que l’US et la TDM sans contraste IV ou entérique ont des performances similaires quant au diagnostic d’appendicite aiguë et de pathologies alternatives, indépendamment de l’expérience du radiologue et de la corpulence du patient. Néanmoins, les examens non concluants (sans diagnostic d’appendicite aiguë ni de pathologie alternative mais où l’appendice n’est pas vu) sont plus fréquents en US qu’en TDM. L’appendice normal, dont la visualisation permet d’exclure le diagnostic d’appendicite aiguë, est plus fréquemment visible en TDM qu’en US, mais en TDM la reproductibilité quant à considérer la même structure comme étant l’appendice dépend du lecteur. L’injection IV de contraste iodé n’augmente pas la proportion d’appendices détectés mais la reproductibilité d’un lecteur particulier. Aucune caractéristique du sujet ni de son appendice, y compris son environnement abdominal, ne permet de prédire cette reproductibilité. La performance de la TDM est constante quelle que soit la dose d’irradiation ou le recours au contraste IV et/ou entérique, indépendamment de la corpulence du patient. La hiérarchie de l’information apportée par les signes évocateurs d’appendicite aiguë n’est pas influencée par la dose; l’infiltration de la graisse péri-appendiculaire et le diamètre appendiculaire en étant les signes les plus prédictifs, malgré le moindre rapport signal/bruit de l’image générée à faible dose. La fréquence de visualisation de l’appendice est aussi indépendante de cette dose. L’exactitude du diagnostic dépend principalement du lecteur mais pas du contraste – quelle qu’en soit la voie d’administration (orale ou IV) – ni de la dose d’irradiation. Le genre du patient influence cependant cette exactitude, le diagnostic étant plus fréquemment correct chez l’homme que chez la femme, en particulier dans les pathologies alternatives.
En conclusion, comme les techniques US et TDM que nous avons investiguées ont des performances équivalentes, les risques associés à l’irradiation et au contraste doivent intervenir dans leur choix. L’US, utilisée en première intention, devrait être complétée par la TDM si son résultat n’est pas concluant. Dans ce cas, la TDM devrait être réalisée, toujours à basse dose d’irradiation, d’abord sans puis, si nécessaire, avec contraste IV et/ou oral.
|
7 |
Quantification non invasive de la microcirculation par imagerie ultrasonore fonctionnelle de contraste avec les techniques de destruction reperfusionLucidarme, Olivier Berger, Geneviève. January 2003 (has links) (PDF)
Thèse de doctorat : Génie biologique et médical : Paris 12 : 2003. / Titre provenant de l'écran-titre.
|
8 |
Contraste des images d'objets amorphes en microscopie électronique à très haute tension.Martinez, Jean Paul, January 1900 (has links)
Th.--Sci. phys.--Toulouse 3, 1978. N°: 812.
|
9 |
Développement d'un microscope super-résolution pour l'imagerie de l'activité neuronaleDeschênes, Andréanne 01 February 2021 (has links)
L’étude de la neurotransmission et de la plasticité synaptique à l’échelle biomoléculaire dans des cellules vivantes nécessite des outils qui permettent la visualisation et la localisation d’une grande variété de protéines synaptiques ainsi que d’autres composantes. La transparence des neurones, la taille nanométrique des structures d’intérêt et leur compacité motivent le choix des modalités d’imagerie pouvant servir à étudier ces phénomènes. La microscopie à super-résolution en fluorescence produit des images ayant une résolution de localisation de l’ordre du nanomètre d’échantillons marqués. Toutefois, cette technique ne permet d’observer que les structures ayant été marquées. C’est pourquoi nous voulons la combiner à une technique ne nécessitant aucun marquage afin d’obtenir le plus d’information possible au sujet de la structure des échantillons. L’imagerie de phase quantitative est une technique sans-marquage qui utilise l’indice de réfraction comme agent de contraste intrinsèque pour cartographier en 3D le contenu cellulaire. Le but principal de ce projet est de concevoir et construire un montage de microscopie de phase quantitative et de l’intégrer à un microscope STED existant de façon à créer un nouveau système d’imagerie multimodale. La performance de ce système sera ensuite caractérisée et sa capacité à produire des images multimodales de synapses de cellules vivantes sera évaluée. Ce projet est un premier pas vers la création d’un outil qui pourrait permettre de simultanément mesurer de façon très précise la position de structures marquées en 2D et 3D et cartographier l’indice de réfraction des cellules en 3D afin de situer les structures marquées dans leur environnement. / The study of neurotransmission at the biomolecular level in live cells requires tools that allow the simultaneous visualisation and localization of a variety of neuronal proteins at their scale: the nanometric scale. In order to do so, an imaging approach offering high spatial and temporal resolution combined to low invasiveness is required. STED microscopy is an optical super-resolution fluorescence microscopy technique that produces images of labelled samples with a spatial resolution below 50 nm in living cells. However, since it is based on the detection of fluorescent molecules, labeling of the structures of interestis necessary and non-labeled structures are invisible for this type of microscope. Therefore, we want to combine it to a label-free optical microscopy technique to maximize the information that can be obtained about the global structure of the samples of interest: optical diffraction tomography (ODT). This approach uses refractive index as an intrinsic contrast agent to produce 3D maps of the cell’s internal contents.The main goal of this project is to design and build a quantitative phase imaging system and to integrate it onto an existing STED microscope to create a novel multimodal super-resolution imaging system. The performance of the microscope will then be characterized. This project is a first step towards the creation of a tool that could eventually allow simultaneous precise2D and 3D mapping of labelled structures and label-free 3D mapping of the sample’s refractive index to situate marked structures in their surroundings.
|
10 |
Segmentation of mammographic images for computer aided diagnosis / Segmentation d’images mammographiques pour l’aide au diagnosticFeudjio Kougoum, Cyrille Désiré 05 October 2016 (has links)
Les outils d’aide au diagnostic sont de nos jours au cœur de plusieurs protocoles cliniques car ils améliorent la qualité du diagnostic posé et des soins médicaux. Ce travail de recherche met en avant une architecture hiérarchique pour la conception d'un outil d'aide à la détection du cancer du sein robuste et performant. Il s’intéresse à la réduction des fausses alarmes en identifiant les régions potentiellement cancérogènes. La gamme dynamique des niveaux de gris des zones sombres est étirée pour améliorer le contraste entre la région du sein et l'arrière plan et permettre une meilleure extraction de celle-ci. Toutefois, le muscle pectoral demeure incrusté dans la région du sein et interfère avec l'analyse des tissus. Son extraction est à la fois difficile et complexe à mettre en œuvre à cause de son chevauchement avec les tissus denses du sein. Dans ces conditions, même en exploitant l'information spatiale pendant la clusterisation par un algorithme de fuzzy C-means ne produit pas toujours des résultats de segmentation pertinents. Pour s'affranchir de cette difficulté, une étape de validation suivie d'un ajustement de contour est mise sur pied pour détecter et corriger les imperfections de segmentation. La seconde étape est consacrée à la caractérisation de la densité des tissus. Pour faire face au problème de variabilité des distributions de niveaux de gris dans les classes de densités, nous introduisons une modification de contraste basée sur un transport optimisé de niveaux de gris. Grâce à cette technique, la surface relative de tissus denses estimée par simple segmentation est très fortement corrélée aux classes de densités issues d’un jeu de données étiquetées. / Computer-aided diagnosis systems are currently at the heart of many clinical protocols since they significantly improve diagnosis making and therefore medical care. This research work therefore puts forward a hierarchical architecture for the design of a robust and efficient CAD tool for breast cancer detection. More precisely, it focuses on the reduction of false alarms rate through the identification of image regions of foremost interest i.e potential cancerous areas. The dynamic range of gray level intensities in dark regions is, first of all stretched to enhance the contrast between tissues and background and thus favors accurate breast region extraction. A second segmentation follows since pectoral muscle which regularly tampers breast tissue analysis remains inlaid in the foreground region. Extracting pectoral muscle tissues is both hard and challenging due to its overlap with dense tissues. In such conditions, even exploiting spatial information during the clustering process of the fuzzy C-means algorithm does not always produce a relevant segmentation. To overcome this difficulty, a new validation process followed by a refinement strategy is proposed to detect and correct the segmentation imperfections. The second macro-step is devoted to breast tissue density analysis. To address the variability in gray levels distributions with of mammographic density classes, we introduce an optimized gray level transport map for mammographic image contrast standardization. Thanks to this technique, dense region areas computed using simple thresholding are highly correlated to density classes from an annotated dataset.
|
Page generated in 0.074 seconds