1 |
Influencia de tipos de cimentos na resistencia a tração de coroas metalicas submetidas a ciclagem termicaSantos, Julie Guzela dos 28 June 2001 (has links)
Orientador : Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T16:57:01Z (GMT). No. of bitstreams: 1
Santos_JulieGuzelados_M.pdf: 2530316 bytes, checksum: f66788a804e87b02ab1d904ca3eec91f (MD5)
Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a resistência à remoção por tração e o tipo de falha da união de coroas totais metálicas fixadas com cimento de Fosfato de Zinco, cimento de Ionômero de Vidro Modificado por Resina e cimento de Resina, sobre preparos padronizados com diferentes tipos de término cervical, após ciclagem térmica. Foram utilizados 72 dentes incisivos inferiores bovinos os quais tiveram suas raízes incluídas em resina epóxica. As porções coronárias foram preparadas em tomo mecânico com paredes axiais com expulsividade de 10° e término cervical em ombros biselado, reto e chanfrado. A obtenção dos padrões de cera foi realizada diretamente sobre os preparos com auxílio de uma matriz para padronização de espessura. As coroas metálicas foram fundidas com liga de Ni-Cr (Verabond 2- Alba Dental Inc.) utilizando maçarico gás/oxigênio. Após a limpeza e jateamento com óxido de alumínio (50micro m), as coroas metálicas foram dividas em 3 grupos de 24 corpos-de-prova correspondentes aos tipos de término do preparo, sendo 08 amostras para cada tipo de agente de fixação. Os três cimentos usados foram manipulados de acordo com os fabricantes em ambiente de temperatura e umidade controlada e as coroas foram fixadas com auxílio de prensa pneumática, com carga estática de 9 kg por 10 minutos. Após 24 horas de armazenagem em estufa a 37°C com umidade relativa de 100 %, as amostras foram submetidas à ciclagem térmica com 500 ciclos entre 5 e 55°C e posteriormente o ensaio de tração foi realizado na máquina de ensaio universal Instron com velocidade de 1 mm/min. Os resultados submetidos a análise estatística ANOV A e ao teste de Tukey (p> 0,05) mostraram que os cimentos foram estatisticamente diferentes,independente do término cervical do preparo. O cimento de resina obteve a maior média de valores de resistência à remoção por tração (24,97 kgf), seguida pelo fosfato (13,35 kgf) e pelo cimento de ionômero modificado por resina (10,16 kgf). Os términos cervicais não apresentaram diferença estatística significante, independente do fator cimento. As falhas de união foram predominantemente do tipo mista para os cimentos de fosfato e de resina, e mista e adesiva para o cimento de ionômero de vidro modificado por resina / Abstract: The purpose of this study was to evaluate the strength tensile of complete cast crowns luted with 3 dental cements. Seventy-two bovin incisors were embedded in epoxic resin. The coronal portions of the teeth were prepared to receive complete crowns using a 4103 diamond bur under refrigeration with 10° of tapering and three types of finishing line 45-degree chamfered, 20-degree bevel shoulder and right shoulder. The wax patterns were made on the prepared teeth with matrix for standardized the thickness. The complete crowns were made with Ni-Cr alloy (Verabond 2 - Alba Dental Inc.). After the crowns were c1eaned and blasted with aluminum oxide (50 micro m) they were separated in three groups of twenty-four specimens each one. Afterwards the crowns were luted to the teeth preparations with zinc phosphate cement (SSWHITE), resin-modified glass ionômero cement (Vitremer-3M) and resin cement with adhesive (Resin Cement and Scothbond-3M). After 24 hours the specimens were submitted to 500 cyc1es between 5°C and 55°C, and to the tension tests on Instron machine with a speed of 1 mm/min. The results were analyzed by ANOV A and Tukey's test (p < 0.05) and the means showed that the great value was in the group of resin cement (24.97 kgf) followed by zinc phosphate (13.35 kgf) and resin modified glass ionomer (10 .16 kgf) alI statistically differents. The three types of finishing line were statistically similar / Mestrado / Mestre em Materiais Dentários
|
2 |
Efeito de cargas cíclicas na resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos pré-fabricados estéticos e metálicos restaurados com coroas de porcelana pura.Xible, Anuar Antonio 27 October 2004 (has links)
Foram avaliados, in vitro, o efeito da aplicação de carga cíclica na resistência à fratura, a resistência à fratura, modo de fratura e associação entre as dimensões MD e VL com resistência à fratura de dentes reconstruídos com sistemas de pinos pré-fabricados metálicos convencionais e estéticos, restaurados com coroas de porcelana pura, submetidos à fadiga térmica e mecânica através de teste à compressão com carga estática. Sessenta caninos íntegros tiveram suas coroas amputadas 1,5mm acima da junção cementoesmalte e preparados para coroa de porcelana pura. Os dente foram distribuídos em 6 grupos de 10 dentes. Os grupos 1 e 2 foram restaurados com pinos pré-fabricados de cerâmica de zircônia Cosmopost (Ivoclar-Vivadent) e núcleo de preenchimento em cerâmica vítrea termo-injetada IPS Empress Cosmo Post (Ivoclar-Vivadent). Os grupos 3 e 4 foram restaurados com pinos pré-fabricados de resina composta reforçada por fibra de vidro FibreKor (Jeneric Pentron) e os grupos 5 e 6 com pinos de titânio AZthec Anchor Titanium (Dentatus). Nos grupos 3, 4, 5 e 6 foi usada resina composta reforçada com fibra de vidro Build It FR Fiber Reinforced Core (Jeneric Pentron) como material para núcleo de preenchimento; os dentes foram restaurados com coroas totais IPS Empress 2 (Ivoclar-Vivadent); tanto os pinos quanto as coroas de porcelana foram cimentados com o sistema resinoso de polimerização dupla Cement It / Bond It Primer A + B (Jeneric Pentron). Os espécimes foram submetidos à ciclagem térmica por 300X, em temperaturas de 5°C e 55°C e incluídos em resina acrílica em blocos de alumínio. Os grupos 2, 4 e 6 foram submetidos à uma carga cíclica de 250N por 500,000X, a uma freqüência de 1,7Hz. Os 6 grupos foram submetidos à carga estática em uma máquina de testes universal até falha dos sistemas. Após a carga estática os espécimes foram avaliados quanto ao modo de fratura e classificados em 02 tipos: Supra-crestal (SC) - quando a fratura se localizou até 1mm abaixo da linha de inclusão dos espécimes na resina acrílica ou Infra-crestal (IC) - quando a linha de fratura se localizou 1,1mm ou mais, abaixo da linha de inclusão dos espécimes na resina acrílica. Os dados foram analisados estatisticamente com os testes ANOVA a 2 critérios, Tukey, Correlação de Pearson, Q Quadrado (χ2) e Exato de Fischer. Na análise da resistência à fratura, o valor do grupo 1 (1165,5±211,95N) foi maior do que o grupo 2 (886,50±170,62N); o do grupo 3 (1041,50±231,20N) foi maior do que o do grupo 4 (762,20±113,63N) e o do grupo 5 (768,90±72,95N) foi maior do que o do grupo 6 (985,40±99,89N) (p<0.05). O valor do grupo de pinos de zircônia foi significantemente maior do que os grupos de pinos de resina composta reforçados por fibras de vidro e titânio (p<0.05), que foram iguais entre si (p=0,146) independente da aplicação da carga cíclica (p<0,05). A carga cíclica diminuiu significantemente a resistência dos dentes restaurados (p<0,05). Houve fraca, porém significante relação entre a dimensão MD e resistência à fratura dos espécimes (r=0,260 e p=0,044). Na análise do modo de fratura, o grupo 1 apresentou 30% de fraturas SC e 70% IC; o grupo 2 apresentou 60% de fraturas SC e 40% IC; o grupo 3 apresentou 60% de fraturas SC e 40% IC; no grupo 4 houve 90% de fraturas SC e 10% de IC; no grupo 5 houve 40% de fraturas SC e 60% de IC enquanto no grupo 6, 50% de fraturas SC e 50% IC. Não houve correlação entre o tipo de pino e modo de fratura (χ2=0,484 e p=0,885), independente do uso de carga cíclica. Em conclusão, os dentes restaurados com pinos de zircônia e núcleos de preenchimento de porcelana vítrea apresentaram os melhores valores de resistência à fratura, independente da aplicação de carga cíclica, entre os grupos testados; o tratamento com carga cíclica reduziu significantemente a resistência em todos os grupos testados. Não houve diferença de resistência à fratura entre os grupos restaurados com resina composta reforçado por fibra de vidro e titânio, independente da aplicação da carga cíclica. Não houve correlação entre o tipo de pino e o modo de fratura, e, quanto maior a dimensão MD dos espécimes, maior a força necessária para levá-los à fratura. / This study compared the effect of cyclic load, survival rate, residual strength, the mode of fracture and relationship between MD and BL dimensions and strength of endodontically treated teeth restored with three esthetic post systems subjected to thermal and mechanical cyclic load. Sixty canines were selected for the study. They were endodontically treated with guta percha points and calcium hydroxide cement (Sealapex Kerr), decoronated 1.5mm above the cementum enamel junction and prepared for metal free ceramic crowns (1.0mm in BL and 0.8mm in MD direction and rounded shoulder), leaving a remaining dentin amount of 1.5mm high as ferrule effect. After BL, MD dimensions were obtained, they were distributed in 6 groups according to the stratified method. Groups 1 and 2 were restored with 1.7mm in diameter zirconia posts (Cosmopost Ivoclar Vivadent) and heat pressed glass-ceramic cores (IPS Empress Cosmo Ivoclar Vivadent); groups 3 and 4 were restored with 1.5mm in diameter fiber reinforced composite posts (FibreKor Jeneric Pentron) and group 5 and 6 were restored with 1.65mm in diameter titanium posts (AZthec Anchor Dentatus). Direct resin composite (Build It FR Jeneric Pentron) were used as cores for the 4 latest groups. All specimens were restored with all ceramic crowns (Empress 2 Ivoclar). In all groups, a resin cement/adhesive system (Cement It/Bond It Primer A+B) was used to lute the posts to root canals and metal free porcelain crowns to the teeth. Twenty-four hours after cementing the crowns, the specimens were subjected to 300x thermal cycles with temperature ranging from 5°C to 55°C with 30sec of dwell time. Specimens were then embedded in resin acrylic, mounted in aluminum blocks. Groups 2, 4 and 6 were subjected 500.000x to a mechanical load of 250N in a frequency of 1.7Hz. All specimens were set in an Instron machine and subjected to static load until failure. Data were recorded and analyzed using Two-way ANOVA,Tukey, Pearson Correlation, Chi Square and Exact Fischer tests. Group 1 (1165.7±210.95N) was higher than group 2 (886.50±170.62N); group 3 (1041.50±231.20N) was higher than group 4 (762.20±113.63N) and group 5 (985.40±99.89N) was higher than group 6 (768,90±72.95 N). Zirconia group values were higher than all the other groups (p<0.05); there was no statistically difference between fiber reinforced composite and titanium group even after the cyclic loading (p=0.146); cyclic loading reduced significantly the fracture strength of all groups (p<0.00); there was no correlation between type of posts and decrease in fracture strength (p=0.778); there were a weak but significant correlation between MD specimens dimension and load to failure (r=0.260 e p=0.044); there was no correlation between the mode of failure and type of posts (χ2=4.484 e p=0.885). It was concluded that: 1-Teeth restored with zirconia posts and glass-ceramic cores showed the highest strength to fracture, regardless the cyclic loading application; 2- The cyclic loading treatment lowered the fracture strength of all groups tested; 3- Fiber reinforced composite posts group values were not significantly different from titanium posts regardless the cyclic loading application; 4- Larger MD dimension may favor an increase in the fracture strength of teeth restored with pre-fabricated post systems.
|
3 |
Estudo comparativo do desajuste cervical, infiltração marginal e resistência à tração de copings metálicos cimentados sobre abutments tipo UCLA preparados com diferentes desenhos de margensRego, Mariana Ribeiro de Moraes 23 August 2005 (has links)
O objetivo desse estudo foi comparar o desajuste cervical, a infiltração marginal e a resistência à tração de copings metálicos cimentados sobre abutments tipo UCLA preparados com três diferentes desenhos de margens: ombro, chanfro profundo e chanferete. Para isso, três abutments UCLA calcináveis receberam preparos padronizados, variando apenas os desenhos de término cervical. Réplicas desses abutments foram industrialmente confeccionadas, sendo 20 de cada desenho de margem, formando assim, os três grupos experimentais. Esses abutments foram fundidos e sobre eles, encerados e fundidos copings metálicos para coroas metalo-cerâmicas. O desajuste cervical foi avaliado em um microscópio comparador Mitutoyo, antes e após a cimentação provisória com TempBond NE. Pela subtração desses valores, foram obtidos os valores de desajuste cervical final para cada espécime. Os espécimes foram então redivididos em dois grupos de 30, com 10 espécimes de cada desenho de margem, sendo que um foi submetido a testes de tração e outro a testes de infiltração marginal após um período de 30 dias. Os valores obtidos foram submetidos aos testes estatísticos. Com relação ao desajuste cervical o teste ANOVA mostrou não haver diferença estatisticamente significante (p > 0.05) entre os grupos avaliados. O mesmo foi comprovado pelo teste de Kruskall-Walis com relação à infiltração marginal. Sobre a resistência à tração, ficou comprovado pelo teste ANOVA, haver diferença estatisticamente significante entre os grupos (p < 0.05). Assim, o teste de Tukey mostrou que essa diferença foi encontrada apenas quando comparados os desenhos em chanferete e chanfro profundo, sendo que o último apresentou maiores valores retentivos. Testes de correlação foram conduzidos para avaliar se houve influência do desajuste cervical na infiltração e na retenção dos copings metálicos, porém, esta correlação não foi estatisticamente significante (p > 0.05). Dessa forma, pôde-se concluir que os diferentes desenhos de margem não influenciaram o desajuste cervical ou a infiltração marginal dos copings metálicos, entretanto, em relação à resistência à tração o desenho em chanfro profundo mostrou valores maiores que o desenho em chanferete, sem apresentar diferenças quando comparado ao desenho em ombro. Pôde-se concluir ainda que não há correlação entre desajuste cervical e infiltração marginal ou retenção dentro das variáveis avaliadas nesse estudo / The aim of this study was to evaluate the cervical disadjustment, the marginal leakage and the tensional strength of metalic supra-structures wich were cemented on UCLA abutments with three different margin designs: shoulder, chamfer and deep chamfer. For that, three UCLA abutments received standardized full crown preparations, where only the margin designs varied. Sixty reproductions of these abutments were custom-made, 20 of each margin design, forming the three experimental groups. These abutments were casted and over them, metalic supra-structures were waxed and casted. The cervical disadjustment was evaluated in a travelling microscope, before and after the cementation with TempBond NE. By the subtraction of these values, the final cervical disadjustment values were obtained for each specimen. The specimens were reorganized in two groups of thirty specimens each, with 10 of each margin design. One of these groups was subjected to tensional tests, while the other to marginal leakage test after a period of water imersion of thirty days. The obtained values were subjected to statistic tests. About the cervical disadjustment, the ANOVA showed no statistically significant difference (p > 0.05) among the evaluated groups. The same was found by Kruskal-Wallis test, related to marginal leakage. Concerning the tensional strength, ANOVA test showed statistically significant difference among the groups (p < 0.05). The Tukey test was aplied for multiple comparisons, and statistic difference was found when chamfer and deep chamfer margin designs were compared, where the last one showed higher retentive values. Correlation tests were conducted to evaluate whether the cervical disadjustment could influence the marginal leakage or the tensional strength. However, these correlations were not confirmed (p > 0.05). Thus, it can be concluded that the different margin designs had no influence either on the cervical disadjustment or on the marginal leakage of the metallic supra-structures. Yet, with regard to tensile strength, the deep chamfer margin design showed higher values then the chamfer margin design, with no differences when compared to the shoulder margin design. No correlation between the cervical disadjustment and the marginal leakage or the tensile strength was found.
|
4 |
Adaptação marginal e resistência à fratura de coroas totais executadas em diferentes sistemas /Campos, Roberto Elias. January 2005 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Adair Luiz Stefanello Busato / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi avaliar a adaptação marginal e a resistência à fratura de coroas totais metalocerâmicas e de coroas sem reforço de infra-estrutura metálica, utilizando-se diferentes sistemas restauradores. Foram selecionadas 48 raízes de dentes bovinos com diâmetros e formas semelhantes, seccionadas com 15 mm de comprimento. Após tratamento endodôntico e alívio do conduto pinos metálicos com 12 mm de comprimento foram fixados com cimento de fosfato de zinco e um preenchimento coronário de resina composta micro-híbrida foi construído com 3 mm de altura e convergência axial de aproximadamente 6 graus. O término cervical foi o ombro arredondado com 1,0 mm de largura. As amostras preparadas e seus respectivos modelos foram aleatoriamente distribuídos em 6 grupos com 8 amostras cada. As amostras foram, então, submetidas a carga de compressão em uma máquina de ensaios EMIC, a uma velocidade de 1 mm/min.. Após obtenção dos valores de resistência à fratura cada amostra foi submetida a uma inspeção visual na lupa estereoscópica para análise do modo de fratura. Para os valores de resistência à fratura, submetidos à análise estatística, o teste de Kruskall-Wallis acusou diferença significante e o teste U de Mann-Whitney indicou os locais de diferença. A análise do modo de fratura mostrou que o remanescente dental foi pouco afetado nas amostras dos grupos das coroas metalocerâmicas (Grupos A e B). Nos grupo C, D e E metade das fraturas ocorreu envolvendo somente o preenchimento coronário e a outra metade envolveu o preenchimento e a raiz do remanescente. O grupo F apresentou 100% de envolvimento do remanescente dental com fraturas cervicais ou longitudinais. Para os dados relativos à adaptação marginal o teste estatístico ANOVA não acusou diferença significante. Todos os grupos apresentaram valores dentro do limite de 100 æm, aceitável clinicamente. / Abstract: The aim of this study was to evaluate the marginal adaptation and fracture resistance of metal-ceramic and metal-free prosthetic unit crowns made with different systems. Forty-eight bovine roots with 15 mm in length were used. After endodontic treatment a metallic post (12 mm) was fixed with zinc phosphate cement and a core of micro-hybrid resin was built up with 3 mm in height, round shoulder cervical termination with 1,5 in width and an approximate axial convergence of 6 degree. Fracture failure mode showed that subjacent structure were little affected in the specimens of metal ceramic groups (A and B). However, inside groups C, D and E half of the fractures involved only the core and the other half involved the core and the remaining dental root. The most catastrophic was the group F with 100% of dental remaining involved, showing cervical and longitudinal fractures in the roots. For marginal adaptation Analysis of Variation (p<0,05) showed no differences among all groups. Means of each group were: A - (74 æm); B (102 æm); C (87 æm); D (99 æm);E (80 æm); F (100 æm). All groups had marginal gap within 100 æm, clinically accepted. / Doutor
|
5 |
Efeito de cargas cíclicas na resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos pré-fabricados estéticos e metálicos restaurados com coroas de porcelana pura.Anuar Antonio Xible 27 October 2004 (has links)
Foram avaliados, in vitro, o efeito da aplicação de carga cíclica na resistência à fratura, a resistência à fratura, modo de fratura e associação entre as dimensões MD e VL com resistência à fratura de dentes reconstruídos com sistemas de pinos pré-fabricados metálicos convencionais e estéticos, restaurados com coroas de porcelana pura, submetidos à fadiga térmica e mecânica através de teste à compressão com carga estática. Sessenta caninos íntegros tiveram suas coroas amputadas 1,5mm acima da junção cementoesmalte e preparados para coroa de porcelana pura. Os dente foram distribuídos em 6 grupos de 10 dentes. Os grupos 1 e 2 foram restaurados com pinos pré-fabricados de cerâmica de zircônia Cosmopost (Ivoclar-Vivadent) e núcleo de preenchimento em cerâmica vítrea termo-injetada IPS Empress Cosmo Post (Ivoclar-Vivadent). Os grupos 3 e 4 foram restaurados com pinos pré-fabricados de resina composta reforçada por fibra de vidro FibreKor (Jeneric Pentron) e os grupos 5 e 6 com pinos de titânio AZthec Anchor Titanium (Dentatus). Nos grupos 3, 4, 5 e 6 foi usada resina composta reforçada com fibra de vidro Build It FR Fiber Reinforced Core (Jeneric Pentron) como material para núcleo de preenchimento; os dentes foram restaurados com coroas totais IPS Empress 2 (Ivoclar-Vivadent); tanto os pinos quanto as coroas de porcelana foram cimentados com o sistema resinoso de polimerização dupla Cement It / Bond It Primer A + B (Jeneric Pentron). Os espécimes foram submetidos à ciclagem térmica por 300X, em temperaturas de 5°C e 55°C e incluídos em resina acrílica em blocos de alumínio. Os grupos 2, 4 e 6 foram submetidos à uma carga cíclica de 250N por 500,000X, a uma freqüência de 1,7Hz. Os 6 grupos foram submetidos à carga estática em uma máquina de testes universal até falha dos sistemas. Após a carga estática os espécimes foram avaliados quanto ao modo de fratura e classificados em 02 tipos: Supra-crestal (SC) - quando a fratura se localizou até 1mm abaixo da linha de inclusão dos espécimes na resina acrílica ou Infra-crestal (IC) - quando a linha de fratura se localizou 1,1mm ou mais, abaixo da linha de inclusão dos espécimes na resina acrílica. Os dados foram analisados estatisticamente com os testes ANOVA a 2 critérios, Tukey, Correlação de Pearson, Q Quadrado (χ2) e Exato de Fischer. Na análise da resistência à fratura, o valor do grupo 1 (1165,5±211,95N) foi maior do que o grupo 2 (886,50±170,62N); o do grupo 3 (1041,50±231,20N) foi maior do que o do grupo 4 (762,20±113,63N) e o do grupo 5 (768,90±72,95N) foi maior do que o do grupo 6 (985,40±99,89N) (p<0.05). O valor do grupo de pinos de zircônia foi significantemente maior do que os grupos de pinos de resina composta reforçados por fibras de vidro e titânio (p<0.05), que foram iguais entre si (p=0,146) independente da aplicação da carga cíclica (p<0,05). A carga cíclica diminuiu significantemente a resistência dos dentes restaurados (p<0,05). Houve fraca, porém significante relação entre a dimensão MD e resistência à fratura dos espécimes (r=0,260 e p=0,044). Na análise do modo de fratura, o grupo 1 apresentou 30% de fraturas SC e 70% IC; o grupo 2 apresentou 60% de fraturas SC e 40% IC; o grupo 3 apresentou 60% de fraturas SC e 40% IC; no grupo 4 houve 90% de fraturas SC e 10% de IC; no grupo 5 houve 40% de fraturas SC e 60% de IC enquanto no grupo 6, 50% de fraturas SC e 50% IC. Não houve correlação entre o tipo de pino e modo de fratura (χ2=0,484 e p=0,885), independente do uso de carga cíclica. Em conclusão, os dentes restaurados com pinos de zircônia e núcleos de preenchimento de porcelana vítrea apresentaram os melhores valores de resistência à fratura, independente da aplicação de carga cíclica, entre os grupos testados; o tratamento com carga cíclica reduziu significantemente a resistência em todos os grupos testados. Não houve diferença de resistência à fratura entre os grupos restaurados com resina composta reforçado por fibra de vidro e titânio, independente da aplicação da carga cíclica. Não houve correlação entre o tipo de pino e o modo de fratura, e, quanto maior a dimensão MD dos espécimes, maior a força necessária para levá-los à fratura. / This study compared the effect of cyclic load, survival rate, residual strength, the mode of fracture and relationship between MD and BL dimensions and strength of endodontically treated teeth restored with three esthetic post systems subjected to thermal and mechanical cyclic load. Sixty canines were selected for the study. They were endodontically treated with guta percha points and calcium hydroxide cement (Sealapex Kerr), decoronated 1.5mm above the cementum enamel junction and prepared for metal free ceramic crowns (1.0mm in BL and 0.8mm in MD direction and rounded shoulder), leaving a remaining dentin amount of 1.5mm high as ferrule effect. After BL, MD dimensions were obtained, they were distributed in 6 groups according to the stratified method. Groups 1 and 2 were restored with 1.7mm in diameter zirconia posts (Cosmopost Ivoclar Vivadent) and heat pressed glass-ceramic cores (IPS Empress Cosmo Ivoclar Vivadent); groups 3 and 4 were restored with 1.5mm in diameter fiber reinforced composite posts (FibreKor Jeneric Pentron) and group 5 and 6 were restored with 1.65mm in diameter titanium posts (AZthec Anchor Dentatus). Direct resin composite (Build It FR Jeneric Pentron) were used as cores for the 4 latest groups. All specimens were restored with all ceramic crowns (Empress 2 Ivoclar). In all groups, a resin cement/adhesive system (Cement It/Bond It Primer A+B) was used to lute the posts to root canals and metal free porcelain crowns to the teeth. Twenty-four hours after cementing the crowns, the specimens were subjected to 300x thermal cycles with temperature ranging from 5°C to 55°C with 30sec of dwell time. Specimens were then embedded in resin acrylic, mounted in aluminum blocks. Groups 2, 4 and 6 were subjected 500.000x to a mechanical load of 250N in a frequency of 1.7Hz. All specimens were set in an Instron machine and subjected to static load until failure. Data were recorded and analyzed using Two-way ANOVA,Tukey, Pearson Correlation, Chi Square and Exact Fischer tests. Group 1 (1165.7±210.95N) was higher than group 2 (886.50±170.62N); group 3 (1041.50±231.20N) was higher than group 4 (762.20±113.63N) and group 5 (985.40±99.89N) was higher than group 6 (768,90±72.95 N). Zirconia group values were higher than all the other groups (p<0.05); there was no statistically difference between fiber reinforced composite and titanium group even after the cyclic loading (p=0.146); cyclic loading reduced significantly the fracture strength of all groups (p<0.00); there was no correlation between type of posts and decrease in fracture strength (p=0.778); there were a weak but significant correlation between MD specimens dimension and load to failure (r=0.260 e p=0.044); there was no correlation between the mode of failure and type of posts (χ2=4.484 e p=0.885). It was concluded that: 1-Teeth restored with zirconia posts and glass-ceramic cores showed the highest strength to fracture, regardless the cyclic loading application; 2- The cyclic loading treatment lowered the fracture strength of all groups tested; 3- Fiber reinforced composite posts group values were not significantly different from titanium posts regardless the cyclic loading application; 4- Larger MD dimension may favor an increase in the fracture strength of teeth restored with pre-fabricated post systems.
|
6 |
Estudo comparativo do desajuste cervical, infiltração marginal e resistência à tração de copings metálicos cimentados sobre abutments tipo UCLA preparados com diferentes desenhos de margensMariana Ribeiro de Moraes Rego 23 August 2005 (has links)
O objetivo desse estudo foi comparar o desajuste cervical, a infiltração marginal e a resistência à tração de copings metálicos cimentados sobre abutments tipo UCLA preparados com três diferentes desenhos de margens: ombro, chanfro profundo e chanferete. Para isso, três abutments UCLA calcináveis receberam preparos padronizados, variando apenas os desenhos de término cervical. Réplicas desses abutments foram industrialmente confeccionadas, sendo 20 de cada desenho de margem, formando assim, os três grupos experimentais. Esses abutments foram fundidos e sobre eles, encerados e fundidos copings metálicos para coroas metalo-cerâmicas. O desajuste cervical foi avaliado em um microscópio comparador Mitutoyo, antes e após a cimentação provisória com TempBond NE. Pela subtração desses valores, foram obtidos os valores de desajuste cervical final para cada espécime. Os espécimes foram então redivididos em dois grupos de 30, com 10 espécimes de cada desenho de margem, sendo que um foi submetido a testes de tração e outro a testes de infiltração marginal após um período de 30 dias. Os valores obtidos foram submetidos aos testes estatísticos. Com relação ao desajuste cervical o teste ANOVA mostrou não haver diferença estatisticamente significante (p > 0.05) entre os grupos avaliados. O mesmo foi comprovado pelo teste de Kruskall-Walis com relação à infiltração marginal. Sobre a resistência à tração, ficou comprovado pelo teste ANOVA, haver diferença estatisticamente significante entre os grupos (p < 0.05). Assim, o teste de Tukey mostrou que essa diferença foi encontrada apenas quando comparados os desenhos em chanferete e chanfro profundo, sendo que o último apresentou maiores valores retentivos. Testes de correlação foram conduzidos para avaliar se houve influência do desajuste cervical na infiltração e na retenção dos copings metálicos, porém, esta correlação não foi estatisticamente significante (p > 0.05). Dessa forma, pôde-se concluir que os diferentes desenhos de margem não influenciaram o desajuste cervical ou a infiltração marginal dos copings metálicos, entretanto, em relação à resistência à tração o desenho em chanfro profundo mostrou valores maiores que o desenho em chanferete, sem apresentar diferenças quando comparado ao desenho em ombro. Pôde-se concluir ainda que não há correlação entre desajuste cervical e infiltração marginal ou retenção dentro das variáveis avaliadas nesse estudo / The aim of this study was to evaluate the cervical disadjustment, the marginal leakage and the tensional strength of metalic supra-structures wich were cemented on UCLA abutments with three different margin designs: shoulder, chamfer and deep chamfer. For that, three UCLA abutments received standardized full crown preparations, where only the margin designs varied. Sixty reproductions of these abutments were custom-made, 20 of each margin design, forming the three experimental groups. These abutments were casted and over them, metalic supra-structures were waxed and casted. The cervical disadjustment was evaluated in a travelling microscope, before and after the cementation with TempBond NE. By the subtraction of these values, the final cervical disadjustment values were obtained for each specimen. The specimens were reorganized in two groups of thirty specimens each, with 10 of each margin design. One of these groups was subjected to tensional tests, while the other to marginal leakage test after a period of water imersion of thirty days. The obtained values were subjected to statistic tests. About the cervical disadjustment, the ANOVA showed no statistically significant difference (p > 0.05) among the evaluated groups. The same was found by Kruskal-Wallis test, related to marginal leakage. Concerning the tensional strength, ANOVA test showed statistically significant difference among the groups (p < 0.05). The Tukey test was aplied for multiple comparisons, and statistic difference was found when chamfer and deep chamfer margin designs were compared, where the last one showed higher retentive values. Correlation tests were conducted to evaluate whether the cervical disadjustment could influence the marginal leakage or the tensional strength. However, these correlations were not confirmed (p > 0.05). Thus, it can be concluded that the different margin designs had no influence either on the cervical disadjustment or on the marginal leakage of the metallic supra-structures. Yet, with regard to tensile strength, the deep chamfer margin design showed higher values then the chamfer margin design, with no differences when compared to the shoulder margin design. No correlation between the cervical disadjustment and the marginal leakage or the tensile strength was found.
|
7 |
Avaliação da resistencia e do padrão de fratura de coroas ceramicas fixadas sobre diferentes reconstruçõesPizi, Eliane Cristina Gava 14 March 2003 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:08:16Z (GMT). No. of bitstreams: 1
Pizi_ElianeCristinaGava_D.pdf: 4414695 bytes, checksum: 1ca7079c5e69cf6ebbf33e2db3e6dc87 (MD5)
Previous issue date: 2003 / Resumo: A proposta deste estudo foi avaliar in vitro a resistência e o padrão de fratura de coroas cerâmicas Cergogold / Dulceragold (Degussa), após fixação adesiva sobre diferentes reconstruções: (G1) preparo coronário em dentina, (G2) resina composta (Z250), (G3) pino de fibra de vidro (FibreKor), (G4) pino de fibra de vidro reembasado em resina composta (FibreKor + Z250), (G5) núcleo em cerâmica prensada (Cergogold), e (G6) núcleo metálico fundido (liga cobre-alumínio). Sessenta incisivos inferiores bovinos tratados endodonticamente, com dimensões médias semelhantes, foram incluídos em cilindros de resina de poliestireno com reprodução do ligamento periodontal. Após a reconstrução dos pinos e da porção coronária mantendo um preparo para coroa total com 60 de expulsividade, foram moldados e as restaurações cerâmicas foram confeccionadas. As coroas foram fixadas e armazenadas em ambiente com 100 % de umidade a 37 °C por 24 horas e, então, submetidas ao carregamento de compressão sob angulação de 135° com velocidade de 0,5 mm/min até a fratura. Os valores de resistência à fratura foram submetidos à análise de variância e posteriormente foi aplicado o teste de Tukey. Foram observados também o padrão de fratura da coroa cerâmica e do sistema de retenção intra-radicular conforme os seguintes critérios. Padrão de fratura da coroa cerâmica: (I) pequena fratura ou trinca na coroa cerâmica, (lI) fratura extensa na coroa cerâmica, (III) fratura extensa da coroa cerâmica com envolvimento da estrutura dental; padrão de fratura da retenção intra-radicular: (a) fratura do núcleo de preenchimento, (b) fratura do núcleo e/ou dente com envolvimento periodontal. Os valores médios do teste de resistência à fratura em Kgf foram: 42,7 ± 10,3 Kgf (G1)a; 42,0 ± 10,9 Kgf (G6)ab; 31,7 ± 6,1 Kgf (G3)bc; 31,5 ± 4,7 Kgf (G4)bc; 27,0 ± 6,4 Kgf (G5)c; 22,2 ± 8,6 Kgf (G2)c. O grupo com preparo em dentina apresentou os maiores resultados de resistência à fratura, semelhante apenas ao grupo do núcleo metálico fundido. Os dois grupos com pinos de fibra de vidro foram semelhantes entre si, e só diferiram do grupo com preparo em dentina. Os grupos que apresentaram resultados inferiores foram o grupo somente preenchido com resina composta e o grupo com núcleo em cerãmica. Quanto ao padrão de fratura, os grupos de fibra de vidro tiveram comportamento semelhante ao grupo com remanescente dentinário na porção coronária, e o único grupo que apresentou fratura radicular com envolvimento periodontal foi o grupo reconstruído com núcleo metálico fundido / Abstract: The aim of this study was to evaluate the fracture strength and failure pattern of Cergogold / Dulceragold (Degussa) ceramic crowns, after adhesive cementation over different core build-ups: (G1) dentin preparation; (G2) composite resin (Z250), (G3) glass fiber post (FibreKor), (G4) composite-rebased glass fiber post (FibreKor + Z250), (G5) pressed ceramic core (Cergogold), and (G6) cast core post (tin-copper alloy). Sixty endodontically treated bovine incisors, with similar dimensions, were included in polystyrene resin cylinders with periodontal ligament reproduction. After crown reconstruction and preparation with and expulsive angulation of 6°, teeth were molded and ceramic restorations were prepared as per manufacturer's instructions. Ceramic crowns were luted and stored at 37 °C and 100 % relative humidity for 24 hours before testing. Specimens were submitted to a compression load at a 135 o angulation and a crosshead speed of 0.5 mm/min until failure. Fracture strength values were statistically analyzed by ANOVA and Tukey testo Mean fracture strength values were: 42,7 ± 10,3 Kgf (G1)a; 42,0 ± 10,9 Kgf (G6)ab; 31,7 ± 6,1 Kgf (G3)bc; 31,5 ± 4,7 Kgf (G4)bc; 27,0 ± 6,4 Kgf (G5)c; 22,2 ± 8,6 Kgf (G2)c. The failure pattern of the ceramic crown and the intra-radicular retention system was determined according to the following types: (I) small fracture or crack in the ceramic crown, (lI) big fracture of the ceramic crown, (III) big fracture of the ceramic crown and core material, (a) fracture of the core material, (b) fracture of the core andj or dental structure with periodontal involvement. The group with dentin preparation presented the highest fracture strength means, similar to the group restored with cast core posts. The groups restored with glass fibers presented similar results, but were statistically different from the group with dentin preparation. The groups which presented the lowest means were the group which was restored only with composite resin and the group restored with a ceramic core posto Regarding the failure pattem, the groups restored with glass fiber posts presented results similar to the group with dentin preparation. The group restored with cast core post presented a high number of failures with periodontal involvement / Doutorado / Dentística / Doutor em Clínica Odontológica
|
8 |
Estabilidade mecanica de retentores do tipo coroa totalSilva, Wilkens Aurelio Buarque e, 1967- 04 July 1995 (has links)
Orientador: Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T11:45:48Z (GMT). No. of bitstreams: 1
Silva_WilkensAurelioBuarquee_M.pdf: 2887452 bytes, checksum: 0b71ed157e45bf5685d0b21d1ab7f5f1 (MD5)
Previous issue date: 1995 / Resumo: O objetivo deste trabalho, foi avaliar a forma de resitência, em preparos para coroas totais, com preservação dos ângulos axo-proximais, variando-se a convergência entre as paredes axiais, com e sem canaletas proximais e, sem a interposição de um meio cimentante. Foram confeccionados oitenta (80) preparos do tipo coroa total com ângulos axo-proximais em dentes naturais. Quarenta (40) com cana retas e quarenta (40) sem canaletas. Os preparos com ombro maior que 90° foram executados com as seguintes convergências: 6°, 8°, 12° e 16° em cada uma das paredes axiais com e sem canaletas axiais proximais, de 0,7mm de profundidade e 4mm de altura. A altura cérvico-oclusal dos preparos foi de 5mm e as dimensões mésio-distais e vestíbulo-linguais em 10mm e 7mm, respectivamente. Para a avaliação de resistência ao deslocamento, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg e 15kg em uma máquina de teste universal, com velocidade constante em 0,5mm/min., aplicadas nas vertentes internas das cúspides f!1ésio-linguais e médio-vestibulares. O registro dos resultados consistiu em visualizar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) o aumento do ângulo de convergência entre as paredes axiais promove uma diminuição da estabilidade mecânica das coroas; b) com 6° e 8° de convergência em cada uma das paredes axiais ocorreu uma estabilidade mecânica ótima nas preparações sem canaletas; c) em 12° e 16° de convergência foi observada falta de estabilidade mecânica nas preparações sem canaletas; d) a utilização de canaletas axiais proximais constitui-se num efetivo meio para otimizar a estabilidade mecânica / Abstract: The objective of this work, was to evaluate the influence of the convergece angle between the axial walls of full crown preparations and the presence of proximal axial grooves, on the resistence form of full crows, without interlocking a cement medium.
Eighty full crown preparations was màde with axo-proximal angles in natural teeth. Fourty with proximal axial grooves and fourty without proximal axial grooves. The preparations with showder larger 90° , was made with the following convergeces: 6°,8°, 12° and 16° in each of the axial walls, with and without proximal axial wals, of 0,7mm deep and 4mm high. The cervico-occlusal heigth of the preparations was 0,5mm and the mesio-distal and bucco-ligual diameters, 10mm and 7mm respectively. To evaluate the resistence form, the patterns adjusted in yours respective preparations, was submited to vertical forces of intensity 3kg, 5kg, 10kg and 15kg in a universal test machine, with speed in 0,5mm/min., applied in the internal vertent of the mesio-lingual and medio-buccal cuspals. The record of the results was to observe the occcurs of dislocation of the paterns. The obtained results shows that: a) the increase of the convergence angle promoves the decrease of the mechanical stabilty of the crowns; b) In 6° and 8° occured a optimal mechanical stability in the preparations without grooves; c) In 12° and 16° was observed the absence of stability in preparations with out grooves; d) The utilization of the proximal axial grooves is a effective option to optimize the mechanical stability, in preparations where the convergence angle is excessive / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
9 |
Turismo de aventura em Três Coroas : análise a partir dos critérios do adventure tourism development indexDecol, Felipe 08 June 2016 (has links)
O turismo de aventura, visto como forma de turismo alternativo, deve seguir os princípios da sustentabilidade. A cidade de Três Coroas utiliza-se de seus recursos naturais na promoção do turismo de aventura. Entre as modalidades de turismo de aventura existentes no município, o rafting é predominante, e identificar como esta atividade se desenvolve é relevante para o desenvolvimento do turismo local. O estudo teve por objetivo avaliar a sustentabilidade das atividades do turismo de aventura em Três Coroas, a exemplo do rafting, utilizando critérios do Adventure Tourism Development Index (ATDI). Os dados da pesquisa foram coletados por meio de entrevistas, observação participante e pesquisas bibliográficas. As entrevistas foram realizadas com cinco empresários das operadoras de turismo de aventura e com o diretor de turismo do município. Os dados coletados foram utilizados para a avaliação e classificação do turismo de aventura do município. A análise destes dados foi feita por meio dos critérios do ATDI. Foram avaliadas como positivas a relação entre o poder público e os empresários, que colocam o turismo como fator estratégico para o desenvolvimento do município, as boas condições da qualidade dos serviços e da infraestrutura. As deficiências foram encontradas na falta de controle sobre a capacidade de carga suportada pelo ambiente, problemas com a poluição do rio Paranhana, utilizado nas atividades de turismo, e carência de serviços básicos que são fundamentais para o desenvolvimento sustentável do turismo, como saneamento básico e saúde. A diversificação das atividades por meio de investimento em novos segmentos de turismo alternativo podem significar melhor aproveitamento do fluxo turístico do município. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2017-01-26T16:18:53Z
No. of bitstreams: 1
Dissertacao Felipe Decol.pdf: 12300371 bytes, checksum: 230e62452d2d9b173874cb664b01daae (MD5) / Made available in DSpace on 2017-01-26T16:18:53Z (GMT). No. of bitstreams: 1
Dissertacao Felipe Decol.pdf: 12300371 bytes, checksum: 230e62452d2d9b173874cb664b01daae (MD5)
Previous issue date: 2017-01-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES / Adventure tourism, as a form of alternative tourism, should follow the principles of sustainability. The city of Três Coroas uses natural resources to promote adventure tourism. Among the existing adventure tourism activities in the city, the rafting is the more relevant activity to the development of local tourism. The research's objective was assess the sustainability of adventure tourism activities in the city of Três Coroas, using the pillars of Adventure Tourism Development Index (ATDI). The survey data were collected by interviews, participant observation and literature research. The interviews were conducted with five businessmen of adventure tourism and the municipal tourism director. The collected data were used for the assessment and classification of Três Coroas' adventure tourism, by the criteria of the Adventure Tourism Development Index. The relationship between public authorities and entrepreneurs, who put tourism as a strategic factor for the city's development, the quality of services, and the infrastructure were assessed as positive. The lack of control, over the carrying capacity supported by the environment, insufficient basic services, that are essential to the sustainable development of tourism, such as basic sanitation and health, and the Paranhana's river pollution problems were classified as negative. The tourism diversification by investing in new alternative tourism segments can mean better utilization of the tourist flow in the city.
|
10 |
Turismo de aventura em Três Coroas : análise a partir dos critérios do adventure tourism development indexDecol, Felipe 08 June 2016 (has links)
O turismo de aventura, visto como forma de turismo alternativo, deve seguir os princípios da sustentabilidade. A cidade de Três Coroas utiliza-se de seus recursos naturais na promoção do turismo de aventura. Entre as modalidades de turismo de aventura existentes no município, o rafting é predominante, e identificar como esta atividade se desenvolve é relevante para o desenvolvimento do turismo local. O estudo teve por objetivo avaliar a sustentabilidade das atividades do turismo de aventura em Três Coroas, a exemplo do rafting, utilizando critérios do Adventure Tourism Development Index (ATDI). Os dados da pesquisa foram coletados por meio de entrevistas, observação participante e pesquisas bibliográficas. As entrevistas foram realizadas com cinco empresários das operadoras de turismo de aventura e com o diretor de turismo do município. Os dados coletados foram utilizados para a avaliação e classificação do turismo de aventura do município. A análise destes dados foi feita por meio dos critérios do ATDI. Foram avaliadas como positivas a relação entre o poder público e os empresários, que colocam o turismo como fator estratégico para o desenvolvimento do município, as boas condições da qualidade dos serviços e da infraestrutura. As deficiências foram encontradas na falta de controle sobre a capacidade de carga suportada pelo ambiente, problemas com a poluição do rio Paranhana, utilizado nas atividades de turismo, e carência de serviços básicos que são fundamentais para o desenvolvimento sustentável do turismo, como saneamento básico e saúde. A diversificação das atividades por meio de investimento em novos segmentos de turismo alternativo podem significar melhor aproveitamento do fluxo turístico do município. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES / Adventure tourism, as a form of alternative tourism, should follow the principles of sustainability. The city of Três Coroas uses natural resources to promote adventure tourism. Among the existing adventure tourism activities in the city, the rafting is the more relevant activity to the development of local tourism. The research's objective was assess the sustainability of adventure tourism activities in the city of Três Coroas, using the pillars of Adventure Tourism Development Index (ATDI). The survey data were collected by interviews, participant observation and literature research. The interviews were conducted with five businessmen of adventure tourism and the municipal tourism director. The collected data were used for the assessment and classification of Três Coroas' adventure tourism, by the criteria of the Adventure Tourism Development Index. The relationship between public authorities and entrepreneurs, who put tourism as a strategic factor for the city's development, the quality of services, and the infrastructure were assessed as positive. The lack of control, over the carrying capacity supported by the environment, insufficient basic services, that are essential to the sustainable development of tourism, such as basic sanitation and health, and the Paranhana's river pollution problems were classified as negative. The tourism diversification by investing in new alternative tourism segments can mean better utilization of the tourist flow in the city.
|
Page generated in 0.0602 seconds