• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • 1
  • Tagged with
  • 97
  • 49
  • 40
  • 36
  • 29
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da resistência à fadiga e modo de falha de coroas de dissilicato de lítio com aplicação de carga nas cristas marginais / Fatigue lifetime and failure mode of lithium disilicate crowns during load application in marginal ridges

Paula, Vitor Guarçoni de 24 June 2015 (has links)
As cerâmicas à base de dissilicato de lítio apresentam propriedades mecânicas, resistência química, biocompatibilidade, baixo índice de acúmulo de placa e resultados estéticos favoráveis. Entretanto, sua resistência à fadiga e probabilidade de sobrevida (confiabilidade) em sua forma estratificada e monolítica ainda é pouco conhecida. Este estudo tem como objetivo investigar a confiabilidade e o modo de falha das coroas estratificadas de dissilicato de lítio com e sem modificação do desenho da infraestrutura e de coroas monolíticas quando submetidas ao ensaio de fadiga por intermédio da ciclagem dinâmica em água. Trinta coroas foram divididas em 3 grupos: IEC (coroas estratificadas com infraestrutura convencional), IEM (coroas estratificadas com infraestrutura modificada) e MON (coroas monolíticas). Para os grupos IEC e IEM as infraestruturas apresentavam espessura de 0,8 mm. No entanto, no desenho modificado era adicionado uma cinta lingual de 2 mm de altura conectada a postes proximais de 3,5 mm de altura, ambos com 1,3 mm de espessura. As MON eram compostas inteiramente de dissilicato de lítio e apresentavam espessura oclusal de 1,5 mm. As coroas foram cimentadas em troqueis de resina composta e submetidas a ciclagem dinâmica em água (30-300 N). Um endentador monolítico de dissilicato de lítio aplicava carga axial sobre a crista marginal mesial até a fratura, e posteriormente na crista distal. Ao final, as coroas eram analisadas em estereomicroscópio e no microscópico eletrônica de varredura (MEV) para caracterização e classificação dos danos. As falhas encontradas nas coroas foram registradas a cada 125.000 ciclos. A distribuição Weibull a 2 parâmetros (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) foi utilizada para calculo da probabilidade de sobrevida em 1, 2 e 3 milhões de ciclos. Comparações entre os grupos também foram realizadas com o módulo de Weibull e a resistência característica (número de ciclos decorrido até a fratura). Tanto em 1 quanto em 2 milhões de ciclos, a probabilidade de sobrevida foi significativamente baixa para as IEM em relação as MON e as coroas IEC não apresentaram diferença entre as IEM e MON. Em 3 milhões, apenas as coroas monolíticas mantiveram a confiabilidade, considerandoque diminuiu significativamente para as estratificadas, independente da modificação da infraestrutura. Fraturas envolvendo os postes proximais e/ou a cinta lingual foram observadas para as IEM, enquanto as IEC o modo de falha predominante foi a fratura coesiva da porcelana de revestimento. As MON também apresentaram fraturas coesivas. As marcas fractográficas identificaram a superfície de contato com o endentador como origem das fraturas. Em conclusão, a alta confiabilidade foi observada para as coroas MON em 3 milhões. As coroas estratificadas não se beneficiaram da modificação das infraestrutura, pois não houve diferença na confiabilidade entre elas nos 3 tempos avaliados. Além disso, o modo de falha no grupo IEM não restringiu a fratura coesiva da porcelana, com presença de fraturas na infraestrutura. Falhas coesivas foram observadas apenas na porcelana de revestimento das IEC e na cerâmica no grupo MON. / Lithium disilicate glass-ceramic provides desirable mechanical properties, chemical resistance, biocompatibility, diminished plaque accumulation, esthetics, and favorable esthetic results. However, the fatigue life and probability of survival (reliability) of lithium disilicate in its monolithic or layered form is still poorly understood. This study aimed to investigate the reliability and failure modes of porcelain veneered lithium disilicate crowns with and without core design modification, and of monolithic crowns when subjected to cyclic fatigue in water. Thirty lithium disilicate molars crowns were made and divided into 3 groups: IEC (bilayer crown with even thickness coping, i.e. conventional core), IEM (bilayer crowns with modified core design) and MON (monolithic crowns). For groups IEC and IEM, copings presented an even thickness of 0.8 mm and the modified design consisted of 1.3 mm thickness with a lingual margin of 2.0mm height connected to full contour proximal struts of 3.5 mm height. Monolithic crowns had an occlusal thickness of 1.5 mm. Crows were luted on composite resin abutment replicas and subjected to cyclic fatigue in water (30-300 N). A monolithic indenter of lithium disilicate was used to deliver the load on the mesial marginal ridge until failure, then the same procedure was performed in the distal ridge. For failure characterization crowns were analyzed in stereomicroscope and scanning electron microscope (SEM). Failure inspection was performed every 125,000 cycles. The 2-parameter Weibull distribution (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) was used calculate the probability of survival at 1, 2, and 3 million cycles. Comparisons between groups were also made for Weibull modulus and characteristic strength (number of cycles elapsed until failure). At both 1 and 2 million cycles, reliability was significantly lower for IEM relative to MON and IEC showed no difference between the IEM and MON. At 3 million cycles, only monolithic crowns maintained the reliability, whereas it significantly decreased for porcelain veneered crowns, regardless of core design modification. Fractures involving the proximal struts and/or lingual collar were observed for IEM crowns, whereas IEC crowns chiefly presented porcelain cohesive failures. MON crowns fractured cohesively. All fractures started occlusaly, as depicted by telltale fratographic marks. In conclusion, the highest reliability was observed for MON crowns at 3 million cycles. Layered lithium disilicate crowns did not benefit from framework design modification, as there was no difference in reliability between them in 3 times evaluated. Also, failure modes differed between groups and IEM did not hinder porcelain cohesive failures, instead fractures involving the framework were observed. Cohesive failures were observed only for the porcelain veneer of IEC, and of the lithium dissilicate material in the MON group.
22

Estudo comparativo da resistência à compressão entre coroa de porcelana aluminizada infiltrada por vidro, coroa de porcelana feldspática e dentes permanentes hígidos / Comparative study of the compressive strength between aluminized porcelain crown infiltrated for glass and crown of feldspática porcelain and hígido permanent natural tooth

Nobrega, Airton Alves da 02 March 2010 (has links)
Este estudo objetivou avaliar a resistência máxima às forças de compressão entre dois grupos diferentes de coroas em porcelanas livres de metal cimentadas sobre dentes naturais e um grupo formado por dentes caninos naturais hígidos e comparar os resultados obtidos com os de (Chaves, 2001), em seu trabalho de Doutorado onde também se avaliou a resistência máxima às forças de compressão entre coroa metalo cerâmica fraturada e reparada com resina composta com coroa metalo cerâmica integra e dente natural permanente. No presente estudo foram feitos vinte preparos para coroa total em dentes naturais caninos e divididos em dois grupos para confecção de dez coroas do sistema cerâmico aluminizado infiltrado por vidro (Angelus Brasil) e dez coroas em porcelana feldspática Noritake ® (Noritake Kisai CO. Cada grupo de coroas foi cimentado com cimento resinoso auto adesivo RelyX Unicem ® , (3M ESPE, Brasil) com o objetivo de aumentar a resistência da porcelana frente às forças de compressão. O teste de compressão foi realizado em uma máquina de ensaio universal KRATOS, através de uma carga aplicada axialmente no ápice da borda incisal de cada espécime até a fratura. Os dados foram submetidos à análise de Variância ANOVA (p < 0,05) e teste de Tukey para comparação entre grupos. Os resultados mostraram que não houve diferença estatisticamente significante entre a coroa de porcelana aluminizada infiltrada por vidro e o dente natural. A coroa de porcelana feldspática apresentou-se menos resistente com relação ao dente natural e coroa de porcelana aluminizada infiltrada por vidro. / The objective of this study is evaluate the maximum load resistance between two different groups of porcelain metal free crown seated on natural teeth and a group of natural canine and to compare the results gotten with the ones of (Chaves, 2001), in its work of Doutorado where also the ultimate strength to the forces of compression between metalo ceramic broken and repaired with composite resin with ceramic crown metaloceramic integrates and permanent natural tooth. In the present study twenty natural canine teeth were prepared for crown canines and divided in two groups: aluminized porcelain crown infiltrated for glass (Angelus Brazil) and feldspathic Noritake Kisai Noritake (co). Crowns were seated using self adhesive resin cement RelyX Unicem (3M ESPE, Brazil) Compression testing was performed by a universal testing machine (KRATOS) by a load applied axially in incisal of each specimen until occurs the fracture. The data were analyzed by one way analyses of variance (ANOVA) and Tukey test for comparison between groups. The results showed that it did not have statistical significant difference between aluminized porcelain crown infiltrated by glass and natural tooth. The feldspathic porcelain crown presented less resistant than natural tooth and aluminized porcelain crown infiltrated by glass. .
23

Análise comparativa da alteração dimensional de materiais de moldagem elastoméricos, através da técnica do casquete

ANDRADE, Cícero Almeida de 18 September 2000 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-05-28T14:00:19Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-06-01T18:20:59Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) / Made available in DSpace on 2018-06-01T18:20:59Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) Previous issue date: 2000-09-18 / O presente estudo avaliou comparativamente a alteração dimensional de quatro materiais de moldagem elastoméricos de consistência fluida (uma silicona por adição, duas siliconas por condensação e uma mercaptana) através da técnica do casquete. Um modelo metálico (padrão) foi confeccionado contendo dois dentes com preparos tipo coroa total. Sobre este modelo, com um alívio metálico de 0,3mm, foram obtidos os casquetes através da técnica de Neelon (técnica do pincel). As moldagens foram realizadas através de uma prensa de carga estática onde uma força de 0,4 kgf assentava as moldeiras sobre o modelo metálico. As faces oclusais dos dentes preparados possuíam ranhuras, em forma de cruz. Na extremidade de cada ranhura havia pequenos pontos a partir dos quais iniciava-se a leitura. A leitura linear, em microscópio comparador, era feita inicialmente na face oclusal de cada dente distintamente, em seguida lia-se ligando os pontos entre os dois dentes. Os resultados foram analisados estatisticamente e concluiu-se que: não houve diferenças estatisticamente significantes. / The present study assessed comparatively the dimensional change of four fluid-consistence elastomeric impression materiais (one addition silicone, two condensation silicones and one mercaptan) using the headcap technique. A metal cast (pattern) was made, enclosing two teeth with metal-crown preparation. On this cast, with a 0,3-mm metal relief, were obtained the headcaps using Neelon's technique (brush method). The impressions were carried out with a static-weight press, where a strength of 39.2 N (newton) was pressing the trays over the metal cast. The occlusal surfaces of the prepared teeth had cross-wise grooves. In the extreme of each groove there were small points where the reading started. The linear reading, in a comparing microscope, was initially done at the occlusal surface of each teeth distinctly, so following it was read matching the points between the two teeth. The results were statistically analysed and it followed that there were no statistically significant differences.
24

Análise da interface adesiva entre cimentos resinosos e diferentes terços da dentina intrarradicular

Suzuki, Thaís Yumi Umeda [UNESP] 18 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-18Bitstream added on 2014-06-13T19:16:55Z : No. of bitstreams: 1 suzuki_tyu_me_araca.pdf: 994382 bytes, checksum: 75c8c1831c920cfd4ce4e1f797803c6c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O propósito deste estudo foi avaliar as técnicas de cimentação adesiva de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através da resistência de união e avaliação de propriedades mecânicas da interface adesiva. Quarenta dentes humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em cinco grupos experimentais (n=8), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo 1: adesivo fotoativado Single Bond 2 + cimento resinoso RelyX ARC; Grupo 2: adesivo dual Excite DSC + RelyX ARC; Grupo 3: adesivo autocondicionante Adper SE Plus + RelyX ARC; Grupo 4: cimento resinoso autoadesivo RelyX Unicem; Grupo 5: cimento resinoso autoadesivo Set. As propriedades mecânicas de dureza e módulo de elasticidade foram mensuradas nas estruturas da interface adesiva em ultramicrodurômetro digital DUH-211. A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal nos diferentes terços da dentina intrarradicular (cervical, médio e apical). Os dados de resistência de união e propriedades mecânicas foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA e teste de Fisher ( = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza Martens e módulo de elasticidade dos materiais adesivos e do substrato dentinário são influenciados pela interação dos materiais resinosos utilizados, bem como pela profundidade intrarradicular. O mesmo fenômeno foi observado no teste de resistência de união. Para os materiais resinosos, houve uma tendência de o terço apical apresentar os menores valores das propriedades analisadas, o que poderia conduzir à realização de preparos intrarradiculares mais conservativos / The purpose of this study was to evaluate techniques for adhesive cementation of glass fiber posts in different thirds of intra-root dentin, through the bond strength and evaluation of mechanical properties of the adhesive interface components. Forty extracted single-rooted human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups (n=8), according to the technique adopted for adhesive cementation of glass fiber posts: Group 1: Single Bond 2 light-cured adhesive + RelyX ARC resin cement; Group 2: Excite DSC dual adhesive + RelyX ARC; Group 3: Adper SE Plus self-etch adhesive + RelyX ARC; Group 4: RelyX Unicem self-adhesive resin cement; Group 5: Set selfadhesive resin cement. The mechanical properties of Martens hardness and elastic modulus were measured in the structures of the adhesive interface in a DUH-211 digital ultramicro hardness tester (Shimadzu). Push-out bond strength was measured in a universal testing machine (Emic DL 3000) in different areas of intra-root dentin (cervical, middle and apical). The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA and Fisher’s test ( =0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of the adhesive materials and dentin substrate can be influenced by the interaction of the materials, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bonding strength test. There was a tendency of the apical region show the least values of mechanical properties, which could stimulate the use of more conservative intraradicular preparation
25

Teste mecânico de compósitos indiretos aplicados diretamente sobre abutments implanto-suportados

Andriani Júnior, Wilson January 2007 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-23T01:48:19Z (GMT). No. of bitstreams: 1 248356.pdf: 800328 bytes, checksum: 2cbd10e89943f6262ee950f18f7b0fee (MD5) / O objetivo deste estudo foi avaliar a resistência a fratura de 3 compósitos indiretos aplicados diretamente sobre abutments de Ti-6Al-4V, implanto suportados. Quarenta e oito abutments coroas integrados foram alocados aleatoriamente em 3 grupos. Os abutments foram submetidos à abrasão (sandblasting) e em seguida foram deixados em recipiente contendo etanol, por 5min no ultra-som. Depois de secos em condições ambientais, um molde personalizado foi utilizado para confecção de coroas idênticas (n=16 por grupo) deTescera (Bisco, Schaumburg,USA), Ceramage (Shofu, Kyoto ,Japan), e Diamond Crown (DRM Research Laboratories,Braford, CT,USA). As coroas foram fabricadas de acordo com as instruções do fabricante. As coroas foram carregadas mecanicamente até a fratura através de um identador posicionado na ponta de uma das cúspides com uma velocidade avaliada em 1mm/min. Em seguida a análise das fraturas foi realizada através de estereomicroscopia e microscópico eletrônico de varredura. ANOVA, com nível de significância 95% e Tukey`s post-hoc para comparações múltiplas foram utilizados para análise estatística. Os resultados de resistência à fratura com este tipo de carga (single-load) foram: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), e Diamond Crown(1155 ± 105Na) (p> 0,85). A análise pela estereomicroscopia mostrou dois modos distintos de fratura das cúspides, com ou sem exposição do abutment. Fraturas sem exposição do abutment ocorreram em aproximadamente 80% das amostras de Tescera, 60% das amostras de Ceramage e 40% das amostras de Diamond. Análise das fraturas através de microscópio eletrônico de varredura (MEV) mostrou múltiplas propagações das trincas em direção a região cervical da coroa, abaixo da região de deformação plástica onde o identador contactava. Uma redução na quantidade de vazios (bolhas) foi observada na microestrutura do Tescera quando comparado com os outros materiais compósitos. Todos os compósitos apresentaram alta resistência à fratura com os valores excedendo a função oclusal normal. The purpose of this study was to test the strength to failure of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments. 48 locking taper abutments were randomly allocated to three groups and were cleaned in ethanol in an ultrasonic bath for 5 minutes. After drying under ambient conditions, the abutments were grit-blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n=16 per group) of Tescera (Bisco, Schaumburg, USA), Ceramage (Shofu, Kyoto, Japan), and Diamond Crown (DRM Research Laboratories, Bran ford, CT,USA). The crowns were produced according to the manufacturer's instructions. The crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% significance level and Tukey's post-hoc multiple comparisons were utilized for statistical analysis. The single load to failure results were: Tescera (1130 ± 105Na), Ceramage (1099 ± 105Na), and Diamond Crown (1155 ± 105Na) (p > 0.85). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment exposure. Fractures without abutment exposure comprised ~80% for Tescera, ~60% for Ceramage, and ~40% for Diamond crown samples. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. A reduced amount of micro structural voids were observed for Tescera compared to the other composite materials. All composite materials presented high strength to failure values which exceeded normal occlusion function.
26

Influência do preenchimento da câmara pulpar com resina composta na resistência ao deslocamento de endocrowns

Chraim, Gustavo Georges de Mattos January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-06-25T20:15:18Z (GMT). No. of bitstreams: 1 305476.pdf: 1935179 bytes, checksum: 8d281337adf073b516287bc7994b091b (MD5) / O objetivo deste estudo foi verificar a influência do preenchimento da câmara pulpar com resina composta na resistência ao deslocamento de endocrowns. Para isso, foram utilizados 20 terceiros molares humanos, sendo eles divididos em dois grupos (n=10). No grupo 1, os dentes foram incluídos e preparados com o desgaste das retenções da câmara pulpar. No grupo 2, os dentes tiveram a câmara pulpar completamente preenchida por resina composta e depois tiveram os preparos confeccionados. As áreas das interfaces aderidas foram medidas com uma fina folha de papel alumínio. Os dentes foram moldados e Endocrowns cerâmicas foram confeccionadas e cimentadas adesivamente. As endocrowns foram submetidas ao teste de tração de coroas 24 horas após a cimentação e os valores transformados em N/cm² submetidos ao teste t de Student. Os resultados mostraram que houve diferenças entre os grupos, sendo que o grupo 2 (2030,95 +-223,24) N/cm² apresentou maior resistência ao deslocamento do que o grupo 1 (1285,2 +- 313,21) N/cm². O preenchimento da câmara pulpar aumentou a resistência ao deslocamento de Endocrowns sob o teste de tração de coroas. / The objective of this study was to determinate the difference of retention of Endocrowns in teeth prepared with and without filling the pulp chamber retentions with composite. 20 human sound molars were divided in two experimental groups (n=10). In group 1, the teeth were prepared for Endocrowns and the retention were removed by wearing the walls of the pulpal chamber. In Group 2, the pulpal chamber was filled with composite and prepared to receive the Endocrown restoration. The surface areas were measured using an aluminium foil, the teeth were molded and ceramic Endocrowns were fabricated and bonded. The pull-off test was performed 24hs after the bonding procedure. The data obtained was submitted to Student´s t test and the result showed that there were differences between the groups, and group 2 (2030,95 +-223,24) N/cm² showed greater resistance to displacement than group 1 (1285+-313,21) N/cm². The filling of the pulp chamber increases resistance to displacement of Endocrowns submitted to the pull-off test.
27

Influência de tratamentos de superfície e agentes cimentantes na sobrevivência de coroas de Y-TZP recobertas por porcelana

Anami, Lilian Costa [UNESP] 28 May 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-28. Added 1 bitstream(s) on 2015-09-17T15:45:36Z : No. of bitstreams: 1 000844478.pdf: 5986811 bytes, checksum: f316ca1188ee9b7817cf579a46c759fd (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi investigar a influência de diferentes tratamentos da superfície interna de coroas e de diferentes agentes cimentantes na sobrevivência de coroas de zircônia parcialmente estabilizada por óxido de ítrio (Y-TZP) recobertas por porcelana. Inicialmente foi realizado um estudo de elementos finitos onde foram comparados os valores e a distribuição das Tensões Máxima Principal (TMP) de espécimes flat e anatômicos, com variações na anatomia dos componentes cerâmicos (coroas de Y-TZP e porcelana, com e sem ponto de contato, com e sem desenho modificado da Y-TZP para suporte da porcelana). As geometrias produzidas em software CAD (Computer-aided design) foram importadas para software de análise de elementos finitos. Foi realizado carregamento pontual e vertical de 200 N sobre o nó central dos modelos. O padrão da distribuição da TMP foi bastante similar entre os modelos estudados, com concentração importante de tensões na zona de singularidade. Considerando a dificuldade de padronização na confecção de espécimes anatômicos durante ensaios laboratoriais, a escolha do modelo simplificado (flat) pode ser justificada. Em uma segunda etapa foram usinados 90 preparos flat em resina epóxica que receberam coroas com infraestrutura em Y-TZP confeccionadas pelo sistema CAD/CAM e recobertas com porcelana pela técnica estratificada. Seis condições foram testadas (n=15): para coroas cimentadas com cimento resinoso Panavia F, quatro diferentes tratamentos foram avaliados (limpeza com álcool isopropílico [PC], aplicação de glaze [POG], jateamento com Al2O3 125 μm [POA]; jateamento com partículas de óxido de alumínio revestidas por sílica de 30 μm [PCJ]); para as coroas cimentadas com cimento de ionômero de vidro (CIV) e de fosfato de zinco (CFZ), as superfícies foram limpas com álcool isopropílico. A resistência à fadiga foi avaliada... / The aim of this study was to investigate the influence of different treatments of the inner surface of crowns and different luting agents on the survival of crowns made of zirconia partially stabilized by yttrium oxide (YTZP) and porcelain. A first study was performed using finite element analysis, where we compared the values and the distribution of Maximum Principal Stresses (MPS) of flat and anatomical specimens, with variations in the anatomy of ceramic components (crowns composed of Y-TZP and porcelain, with and without contact point, with and without a modified design of Y-TZP supporting the porcelain). The geometries produced in CAD software (Computer-Aided-Design) were imported for a finite element analysis software. A punctual and vertical load of 200 N was carried out on the central node of the models. The MPS distribution was quite similar among the studied models with important stress concentration in the singularity zone. Considering the lack of standardization in the preparation of anatomical specimens for laboratory tests, the choice of the simplified model (flat) could be justified. In a second step, 90 flat preparations were machined in epoxy resin and received crowns with Y-TZP infrastructure made by CAD/CAM system and veneered with porcelain by the stratified technique. Six conditions were tested (n=15): for crowns cemented with Panavia F, four different treatments were evaluated (cleaning with isopropyl alcohol [PC], overglaze application [POG], sandblasting with 125 μm particles of Al2O3 [POA]; sandblasting with 30μm particles of SiO2 [PCJ]); for crowns cemented with glass ionomer cement (CIV) and zinc phosphate (CFZ), the inner surface were cleaned with isopropyl alcohol. The fatigue resistance was evaluated by the number of mechanical cycles required for fracture of the specimens through stepwise loads methodology. Samples were cycled for 5,000 cycles at 200 ...
28

Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas in vivo

Pavanelli, Carlos Augusto [UNESP] 18 June 1997 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:18Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-18. Added 1 bitstream(s) on 2015-12-10T14:28:21Z : No. of bitstreams: 1 000125620.pdf: 2996163 bytes, checksum: f515bf3dab8364f60e260ee782ec47e0 (MD5) / A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que... / This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement
29

Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação

Fonseca, Renata Garcia [UNESP] 01 October 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-10-01Bitstream added on 2014-06-13T20:25:47Z : No. of bitstreams: 1 fonseca_rg_dr_arafo.pdf: 347306 bytes, checksum: 7bab875463a1706adf2e01435b649315 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo-se ou não os cimentos resinosos Panavia F, Scothbond Resin Cement, Enforce e Cement-It à fotoativação, tendo as leituras sido realizadas nos tempos imediato, 1 hora, 2 horas, 24 horas e 7 dias após espatulação dos materiais. No segundo ensaio, foram confeccionados troquéis e coroas, ambos em liga de NiCr, os quais, após jateamento e aplicação do agente catalisador do sistema adesivo Scotchbond Multi Uso Plus (3M) em suas superfícies, foram cimentados aos pares com os materiais descritos anteriormente, além do cimento de fosfato de zinco. A análise dos resultados revelou que os cimentos resinosos alcançaram maior dureza nos grupos fotoativados em todos os tempos analisados, com exceção apenas do Scotchbond Resin Cement e Enforce que, aos 7 dias, mostraram igualdade estatística entre os tratamentos. Todos os materiais apresentaram progressão de polimerização em função do tempo na ausência de luz, com diferentes velocidades. Os cimentos Panavia F e Fosfato de Zinco apresentaram, respectivamente, a maior e a menor força de remoção por tração, tendo o Scotchbond Resin Cement, Enforce e Cement-It ficado em posição intermediária, diferenciando-se significativamente dos demais materiais, porém não entre si. / The purpose of this study was to evaluate plymerization degree of resin cements subjected to various light exposures, by hardness test, and bond strength of crowns luted to dies using five luting agents. Panavia F, Scothbond Resin Cement, Enforce and Cement-It were exposed or not to light and measurements were taken at baseline, 1 hour, 1 hours and 7 days after mixing. For the second evaluation, dies and crowns were obtained with NiCr alloys and after sandblasting and treatment with catalyzer agent of Scotchbond Multi Uso Plus adhesive system (3M) at both surfaces, cementation was done with the luting agents described before, besides zinc phosphate cement. Statistical analysis revealed greater hardness for photopolymerized groups in all times, excepting Scotchbond Resin Cement and Enforce that, at 7 days, showed no statistical difference between treatments. All cements had polymerization progression with time at light absence, with different speeds. Panavia F and zinc phosphate showed, respectively, the greatest and smallest bond strength, while Scotchbond Resin Cement, Enforce and Cement-It were in a intermediate position, differing significantly of the other cements, but not between theirserlves.
30

Fratura precoce da porcelana em restaurações com infra-estrutura de zircônia: influência de gradientes térmicos no desenvolvimento e magnitude de tensões residuais e transitórias

Benetti, Paula [UNESP] 01 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-01Bitstream added on 2014-06-13T20:45:49Z : No. of bitstreams: 1 benetti_p_dr_sjc.pdf: 1295026 bytes, checksum: 84c067e5318d9cb1124bfd1cbcf324f7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esse estudo avaliou o desenvolvimento de tensões dentro da porcelana de restaurações metalo-cerâmicas (MC) e de zircônia-porcelana (ZC) como resultado de diferentes taxas de resfriamento a partir de temperaturas acima da transição vítrea (Tg). Restaurações unitárias (coroas) foram fabricadas com 1 ou 2 mm de espessura de porcelana. Termopares foram posicionados nas superfícies de cimentação (T1) e oclusal (T4) e inseridos na interface (T2) e dentro da porcelana (T3). Para o resfriamento rápido, o forno foi aberto imediatamente após o tempo de sinterização e desligado. O resfriamento lento foi obtido pela abertura do forno quando a 50°C abaixo da Tg. Modelos axi-simétricos foram construídos para simulação de tensões térmicas tempo-dependentes usando análise de elementos finitos (AEF). Equações de temperatura em função do tempo obtidas por termopares foram inseridas no modelo como condições das margens. A mudança do coeficiente de expansão térmica, densidade, módulo de cisalhamento, capacidade térmica e da Tg de acordo com a taxa de resfriamento foi considerada para simulação do comportamento da porcelana em temperaturas acima da Tg (visco-elástico). O comportamento dos materiais de infra-estrutura e da porcelana abaixo da Tg foi considerado elástico. A taxa de resfriamento na faixa de temperatura próxima a Tg foi 20°C/min e 900°C/min para resfriamento lento e rápido. Durante o resfriamento lento, os diferentes termopares mostraram temperaturas similares em ambas as coroas. Gradientes de temperatura foram observados no resfriamento rápido da coroa ZC (T1-T4 = 100°C) e, em menor magnitude, para a MC (T1-T4 = 30°C). Os resultados de AEF mostraram diferenças de tensão... / This study evaluated the development of transient and residual stresses within the porcelain of veneered restorations (zirconia- and metal-based) as a result of different cooling rates from temperatures above the glass transition temperature (Tg). All-ceramic (porcelain on zirconia-based ceramic) and porcelain-fused-to-metal (PFM) molar crowns were fabricated with 1 mm or 2 mm porcelain thickness. Thermocouples were attached to intaglio (T1) and occlusal (T4) surfaces and embedded within the ceramics interface (T2) and inside the porcelain (T3) to acquire temperature readings by time. For fast cooling, the furnace was opened immediately after the holding time and switched off afterward. Slow cooling was determined by opening the furnace when it reached 50 °C bellow the Tg. Axially-symmetric crown-like models were constructed to perform a simulation of time-dependent thermal stresses using finite element analyses (FEA). Time-dependent temperature equations from thermocouples were set as boundary conditions for surfaces of the model. Coefficient of thermal expansion, density, shear modulus, heat capacity and Tg dependency on cooling rate were considered for the porcelain simulation (visco-elastic above Tg). Porcelain below the Tg and the framework materials were considered to behave elastically. The cooling rates at Tg range were 20 °C/min and 900 °C/min for slow and fast cooling. During slow cooling, different thermocouples showed similar temperatures for both zirconia and metal crowns. Remarkable temperature gradients were observed for the fast cooled all-ceramic crown (T1-T4 = 100 °C) and, of lower magnitude, for PFM (T1-T4 = 30 °C). FEA results showed differences... (Complete abstract click electronic access below)

Page generated in 0.0638 seconds