• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • 1
  • Tagged with
  • 97
  • 49
  • 40
  • 36
  • 29
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influência do acabamento de preparos para coroas totais com microscópio operatório na adaptação marginal de restaurações em cerâmica tipo CAD-CAM

Oliveira, José Pedro Peixoto de January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:16Z (GMT). No. of bitstreams: 2 000399743-0.pdf: 674310 bytes, checksum: 694cbc44bc682f21bed71e69a6f99e90 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study assessed the marginal adaptation of full crown Lava (3M/ESPE) zirconium infrastructure under three different finishing instruments. Thirty human premolars, extracted for therapeutic reasons, were fixed in acrylic resin platforms. The teeth were randomly assigned to three groups (n=10) according the proceedings to cut a full crown preparation: Group 1 - diamond bur; Group 2 - diamond bur and 12-bladed finishing bur; Group 3 - diamond bur and a 12-bladed finishing bur under a 12. 5 X magnification operating microscope. Impressions were taken with an addition silicone material and dies were formed with a special stone. The dies were sent to 3M/ESPE laboratory to have a Lava zirconium infrastructure machined to each specimen. The copings were cemented to the corresponding tooth with RelyX Unicem cement. The restored specimens were embedded in acrylic resin and cut mesio distally and buccal lingually. Eight surfaces were observed with a stereomicroscope at x70 and digital images were obtained. The marginal adaptation measurements were carried out in the Image Tool program. According to ANOVA and Tukey´s test (α=0. 05), there was no statistic difference between Group 1 (88. 601 μm) and Group 2 (90. 946 μm). The lowest mean was obtained for Group 3 (58. 497 μm), and this mean was statistically different than those groups. It was concluded that the operating microscope provided better marginal adaptation of the Lava copings. / Este estudo teve o objetivo de avaliar a adaptação de infra-estruturas de cerâmica Lava (3M/ESPE) com três diferentes tipos de acabamento em preparos para coroa total. Trinta pré-molares humanos, extraídos por razões terapêuticas, foram fixados em blocos de resina acrílica e divididos aleatoriamente em três grupos (n=10) de acordo com o procedimento para realizar os preparos: grupo 1 - ponta diamantada; Grupo 2 - ponta diamantada e broca multi-laminada; Grupo 3 - ponta diamantada e broca multi-laminada, sendo este último instrumento com o uso do microscópio operatório em aumento de 12,5 vezes. Os preparos foram moldados com silicone por adição e os modelos obtidos em gesso especial tipo IV. Os modelos foram enviados para o laboratório da 3M/ESPE, o qual confeccionou os casquetes de cerâmica Lava. As infra-estruturas foram cimentadas nos dentes preparados com RelyX Unicem, sendo então incluídos em blocos de resina acrílica e cortados em dois planos: mésio-distal e vestíbulo-lingual. Desta forma, obteve-se quatro fragmentos, sendo que cada fragmento forneceu duas regiões para observar a discrepância das margens. Por meio de lupa estereoscópica, acoplada a uma câmera de vídeo, foram obtidas imagens digitais da região das margens em aumento de 70 vezes. As medidas de adaptação marginal foram realizadas no programa Image Tool. De acordo com ANOVA e teste de Tukey (α=0,05), não houve diferença estatística entre os Grupo 1 (88,601 μm) e Grupo 2 (90,946 μm). A menor média foi obtida para o Grupo 3 (58,497 μm), diferindo estatisticamente dos outros dois grupos. Pôde-se concluir que o emprego do microscópio operatório favoreceu a melhor adaptação marginal nos casquetes de cerâmica Lava.
62

Avaliação da adaptação cervical de coroas totais metalicas com diferentes terminos antes e apos a cimentação

Brisolara, Paulo Gilberto da Silveira 27 September 2000 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T00:03:33Z (GMT). No. of bitstreams: 1 Brisolara_PauloGilbertodaSilveira_M.pdf: 2380503 bytes, checksum: edcc34fb503e863b41cb601c8ce011ef (MD5) Previous issue date: 2000 / Resumo: o propósito deste estudo foi avaliar o ajuste cervical antes e após a cimentação de coroas totais metálicas confeccionadas com liga de níquel-cromo (Verabond 11), em preparos sobre dentes bovinos com diferentes términos cervicais: chanfro em 45° , ombro biselado em 20° e ombro reto, com os cimentos de fosfato de zinco, ionômero de vidro e resinoso. Noventa coroas totais metálicas foram fundidas com a liga de níquel-cromo (Verabond 11) utilizando o maçarico gás-oxigênio. Após a fundição, as coroas foram adaptadas sobre os preparos com carga estática de 9 kg. A discrepância marginal foi medida com micrômetro digital (Mitutoyo) e as coroas metálicas foram fixadas sobre os dentes com os cimentos de fosfato de zinco, ionômero de vidro e resinoso, manipulados de acordo com as recomendações dos fabricantes. Em seguida, a discrepância marginal foi medida novamente. Os resultados submetidos à análise de variância e ao teste de Tukey (5%) e indicaram que: antes da cimentação, o término cervical em ombro biselado em 20° mostrou a maior média de desajuste cervical, sendo diferente estatisticamente do chanfro em 45° e ombro reto, também diferentes entre si; após a cimentação, para cada tipo de cimento, o melhor ajuste cervical foi obtido com o término cervical em ombro reto, seguido pelo chanfro em 45° e ombro biselado em 20°; independente do término cervical, as coroas metálicas fixadas com o cimento de ionômero de vidro apresentaram os melhores resultados, seguido pelo cimento de fosfato de zinco e cimento resinoso / Abstract: The purpose of this study was to analyse the cervical fits before and after cementation of full cast crowns made with nickel-chromium alloy (Verabond 11), with three different marginal designs: 45-degree chamfered, 20-degree bevel shoulder and right shoulder, on the bovino teeth with zinc phosphate, glass ionomer and resin cements. Ninety crowns were cast with nickel-chromium (Verabond 11) melted by gas-oxygen torch. After casting the crowns were seated on different marginal configurations with a static load of 9 kg. The marginal discrepancy was measured before cementation using a digital micrometer (Mitutoyo). Afterwards, the crowns were luted onto the tooth with zinc phosphate, glass ionomer and resin cements mixed with standardized proportions and procedures, the marginal discrepancy was measured again. The results were submitted to analysis of variance and Tukey's test (5%) and indicated that before cementation the marginal designs: 20-degree bevel shoulder showed the most average cervical fits, being statistically different in relation to 45-degree chamfered and right shoulder, also different between them. After cementation, for each cement, the better fits were obtained with right shoulder in relation to 45-degree chamfered and 20 degree bevel shoulder. Independent of marginal configurations, the full cast crowns luted with glass ionomer cement showed the better cervical fits in relation to zinc phosphate and resin cements / Mestrado / Mestre em Materiais Dentários
63

Distribuição de tensões em coroas totais com sistema metal-free por meio do método de elementos finitos

Lima, Liliane Motta de 20 January 2016 (has links)
Submitted by Gábia Leite (gabya.leite@gmail.com) on 2016-06-24T15:24:45Z No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:45:15Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:47:43Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Made available in DSpace on 2016-07-05T14:47:43Z (GMT). No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) Previous issue date: 2016-01-20 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study compared the stress distribution between three-dimensional lower first molar crowns of indirect resin Lava Ultimate (3M ESPE) (LU) and ceramic IPS e.max CAD (Ivoclar Vivadent) (Emax) against the application of functional load. Three variables were studied by the method of finite elements: the type and thickness of restorative material (1 or 2 mm) as well as the direction of the applied load (axial or oblique). On a modeling software (Rhinoceros; 5.0, Robert Mcneel & associates, USA), CAD models of total crown preparation were generated with different thicknesses of occlusal wear and their indirect restorations. Then in Femap® (10.2, Siemens PLM Software, USA) software, the construction of the finite element mesh was made. After checking the quality of this, the elastic modulus and Poisson's ratio of the tested materials were inserted in the program. After, in Nei Nastran software (10.0.3.7, NEi Software, USA), it was carried out the study of stress distribution from the simulation of models with a load of 200 N on the central fossa region and near the tip of the distobuccal cusp ridge, corresponding to a lower first molar crown. Data analysis was based on a qualitative description of the generated images and also on the values of maximum principal stress of each CAD model. According to the results, the LU crowns behaved as transmission structures of stresses and the complex tooth/restoration as a single block in which stress was distributed more evenly. In Emax crowns, however, the tensile stresses concentrated particularly along the thickness of the material. The more favorable stress distribution was obtained with the 2 mm thickness crowns in an axial occlusal load application, especially for the LU material. / O presente estudo comparou a distribuição de tensões entre coroas de primeiro molar inferior tridimensionais de resina laboratorial Lava Ultimate; 3M ESPE (LU) e de cerâmica IPS e.max CAD; Ivoclar Vivadent (Emax) frente à aplicação de carga funcional. Três variáveis foram estudadas pelo método de elementos finitos: o tipo e a espessura de material restaurador (1 e 2 mm), assim como a direção da carga aplicada (axial e oblíqua). Em um programa modelador (Rhinoceros®; versão 5.0, Robert McNeel & Associates, USA), foram gerados modelos CAD (desenhados com auxílio do computador) de preparos de coroa total com diferentes espessuras de desgaste oclusal e suas respectivas restaurações indiretas. Em seguida, no software Femap® (versão 10.2, Siemens PLM Software, USA), realizou-se a construção da malha de elementos finitos e, após a verificação da qualidade desta, o módulo de elasticidade e o coeficiente de Poisson dos materiais testados foram inseridos no programa. Posteriormente, no software Nei Nastran (versão 10.0.3.7, NEi Software, USA), realizou-se o estudo da distribuição de tensões a partir da simulação computadorizada dos modelos com um carregamento de 200 N nas regiões de fossa central e vertente triturante da cúspide médio-vestibular, correspondentes a um primeiro molar inferior. A análise dos dados baseou-se em uma descrição qualitativa das imagens geradas e nos valores obtidos das tensões principais máximas de cada modelo CAD. De acordo com os resultados, as coroas de LU se comportaram como estruturas transmissoras de tensões e o complexo dente/restauração como um bloco único no qual as tensões foram distribuídas de forma mais homogênea. Nas coroas de Emax, ao contrário, as tensões de tração se concentraram, sobretudo, ao longo da espessura do material. A distribuição de tensões mais favorável foi obtida com as coroas de 2 mm de espessura oclusal em uma aplicação axial da carga, principalmente para o material LU.
64

Influência da ciclagem com cargas dinâmicas na microinfiltração de coroas metalocerâmicas cimentadas com três tipos de cimento

Paulo Henrique Orlato Rossetti 29 April 2003 (has links)
O propósito deste estudo foi avaliar "in vitro" as mensurações e possíveis correlações entre discrepância de assentamento, abertura marginal e padrão de microinfiltração, em coroais metalocerâmicas cimentadas com três tipos de agentes cimentantes: fosfato, ionômero e cimento resinoso dual. Trinta dentes pré-molares humanos extraídos foram preparados para coroas metalocerâmicas e as fundições foram realizadas com liga de Ni-Cr. As amostras foram divididas em três grupos, de acordo com o agente cimentante e a cimentação foi realizada sob uma carga de 5Kg por 10 minutos e as amostras armazenadas em água por 24hs. A discrepância de assentamento foi registrada antes e após a cimentação em um microscópio óptico com precisão de 0,001micrometro. Metade dos espécimes dentro de cada grupo foi submetida ao teste de fadiga cíclica (50.000 ciclos, 2,5Hz). As coroas foram seccionadas longitudinalmente no sentido vestíbulo-lingual e na interface coroadente-cimento foi aplicado um corante (rodamina B) por 15 segundos. A penetração do corante foi quantificada ao longo da interface sob um microscópio óptico (80 vezes de aumento) e, posteriormente, as amostras foram preparadas para microscopia eletrônica de varredura a fim de quantificar a abertura marginal e a qualidade da interface. Os resultados de discrepância de assentamento foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, sem diferença estatística. Foram encontradas diferenças estatisticamente significantes entre a discrepância de assentamento e a abertura marginal para os três cimentos. Os resultados de infiltração foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, com diferenças estatisticamente significantes. A ciclagem mecânica aumentou a infiltração marginal para o cimento fosfato de zinco, com diferença estatisticamente significativa em relação ao cimento ionomérico e resinoso. A análise ao microscópio eletrônico de varredura detectou melhor qualidade de união na interface dente-cimento para o sistema resinoso, seguido pelo cimento ionomérico e resinoso. / The purpose of this study was to verify "in vitro" measures and possible correlations between seating discrepancy, marginal opening and microleakage pattern under total metallic crowns cemented with three types of luting agents: phosphate, glass-ionomer and resin dual cement. Thrirty extracted human premolars teeth were prepared for total metalloceramic crowns and castings obtained with a Ni-Cr alloy. Samples were ramdomly assigned for three groups in according to each luting agent: zinc phosphate (S.S.White), resin-modified glass-ionomer (Vitremer-3M) or a dual resin cement (Enforce-Dentsply). Cementation was done under a 49N load for 10 minutes and water stored for 24hs. Vertical discrepancy was registered before and after cementation in an optical microscopy with the accuracy of 0,001mm). Half of the specimens within each group was submitted to a cyclic loading test (50000 cycles, 2,5Hz). Crowns were longitudinally seccionated in a bucco- lingual plane at the tooth-cement-crown interface and dye solution (rodhamine B) was apllied to tooth-cement- interface for 15 seconds The linear stain penetration along tooth-cement was quantified. under a light microscope (80X magnification) and then samples were prepared for scanning electronic microscope in order to quantify marginal opening and the quality of interface. The results for seating discrepancy were higher for zinc phosphate, followed by glass-ionomer and resin cement, with no statistical difference. Statistically significant differences were found between seating discrepancy and marginal opening for the three cements. Microleakage results were higher for zinc phosphate, followed by glass-ionomer and resin cement, with statiscally significant differences. Fatigue loading rinsed marginal leakage for zinc pohsphate, with statiscally significant difference in respect to glassionomer and resin cement. Scanning electron microscope analysis showed better marginal quality at the tooth-cement-restoration interface for resinous cement,followed by glass-ionomer and zinc phosphate cement.
65

Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brands

Cintia Lumi Nishida 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
66

Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função / Fractures Incidence on fixed prostheses: a retrospective study

Fabiola Pontes Azevedo 09 August 2017 (has links)
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação. / Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.
67

Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas / Evaluation of failure mode of ceramic crowns with and without framework design modification.

Fabio Cesar Lorenzoni 25 March 2009 (has links)
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterada) das coroas metalocerâmicas (MC) e das ceramocerâmicas (CC), denominadas de MCSA e CCSA para as I.E. com desenho padrão e MCCA e CCCA para as com alteração no seu desenho. As infraestruturas com desenho padrão apresentaram espessura de 0,5mm em todas as suas paredes e as com alteração no desenho apresentaram a cinta lingual com 2,0mm de altura e postes proximais com 3,5mm de altura e as demais áreas com 0,5mm de espessura. As coroas ceramocerâmicas consistiam do sistema à base de alumina (In-Ceram Alumina slip cast) e as infraestruturas das coroas metalocerâmicas foram fabricadas com metal não nobre (Ni-Cr). Todas as coroas foram cimentadas com cimento resinoso Rely X ARC sobre uma réplica do preparo de resina composta, a qual teve a proposta de simular o módulo de elasticidade encontrado na dentina. Estas coroas foram submetidas ao teste de resistência à fadiga, ciclagem dinâmica, por 106 ciclos ou até que qualquer tipo de fratura fosse observada, com carga variando entre 30-300N. A força foi aplicada axialmente entre as vertentes palatina e vestibular, com endentador metálico esférico. Em intervalos de 125.000 as coroas eram verificadas à procura de danos com auxílio de estereomicroscopia. As coroas que não sofreram fraturas foram polidas sequencialmente e cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. O teste Kruskal Wallis foi utilizado para verificar se houve diferença estatisticamente significante entre os materiais e o teste de Student-Newman-Keusl foi utilizado para as comparações múltiplas. Diferenças estatisticamente significante foi encontrada entre materiais e desenhos, entretanto, os grupos com I.E. metálica (MCCA e MCSA) não apresentaram diferença estatisticamente significante. O grupo CCCA mostrou diferença estatisticamente significante em relação ao grupo CCSA. A presença do metal na infraestrutura foi preponderante na resistência à fadiga. A alteração no desenho da infraestrutura cerâmica provou ser superior em relação ao desenho sem alteração. / Ceramic crowns have been widely used, however, problems related to brittle fracture of these materials persist, especially in the posterior area. The present study tested the null hypothesis that there were no differences in fatigue resistance related to the framework design as well as to the materials used. One maxillary molar was prepared, reproducing the complex morphology of a dental preparation, to receive metal-ceramic and all-ceramic crowns. Four groups (n=10) were established based on framework designs (standard and modified) for metal-ceramic (MC) and all-ceramic (CC) crowns, named as MCSA and CCSA for standard framework designs and MCCA and CCCA for the proposed framework design modifications. On the standard design, frameworks presented 0.5mm thick walls and those with design modification a 0.5mm thick framework with a vertical increase of 2.0mm lingual and 3.5mm proximal walls. All-ceramic frameworks were made with In-Ceram Alumina slip cast and the metal-ceramic frameworks were made with nickel-chromium alloy. All crowns were cemented with resin cement (Rely X ARC) on resin composite replicas, witch have an elastic modulus similar to dentin. They were subjected to dynamic cycling fatigue test (106 cycles or until fracture), at ranging load of 30-300N. Load was located between the buccal and lingual cuspals of the crowns. At 125.000 cycles intervals, crowns were analysed under a stereomicroscopy to search for damages. Crowns without fracture were polished sequentially and received scores according to the failure mode. Kruskal Wallis test was used to check if there were a significant differences between the framework design and materials (metal and ceramic) and the Student-Newman-Keuls was used for multiple comparisons. Significant differences were found between materials and designs, however, both metal frameworks (MCCA e MCSA) were similar. CCCA group showed higher survival than CCSA group. The metal presence in the framework seemed to improve the resistance to fatigue test. However, the design modification in ceramics achieved better results than the standard design.
68

Avaliação do modo de falha de coroas ceramocerâmicas de zircônia em função do protocolo de resfriamento e do desenho de infraestrutura / Evaluation of the zirconia crowns failure mode depending on cooling protocol and framework design

Vitor Guarçoni de Paula 31 May 2011 (has links)
As excelentes propriedades mecânicas da zircônia como elevada resistência flexural e tenacidade à fratura fez com ela fosse o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, mesmo com elevadas propriedades mecânicas os problemas relacionados a fratura ainda persistem. Variáveis como a baixa condutibilidade térmica da zircônia e a falta de suporte das infraestruturas às porcelanas são indicadas como possíveis causas. O presente estudo teve o objetivo de verificar se a modificação do desenho da infraestrutura e a alteração do protocolo de resfriamento durante a fase de glaze são capazes de melhorar a resistência das coroas ceramocerâmicas com infraestruturas de zircônia. Quarenta coroas unitárias com infraestruturas de zircônia (IPS e.max ZirCAD) na forma de molares foram confeccionadas sobre preparos padronizados e divididos em 4 grupos: ZrCRP (coroas com infraestruturas convencionais e resfriamento padrão), ZrMRP (coroas com desenho de infraestrutura modificado e resfriamento padrão), ZrCRL (coroas com infraestruturas convencionais e resfriamento lento) e ZrMRL (coroas com desenho de infraestrutura modificado e resfriamento lento). As infraestruturas com desenho convencional apresentavam espessura uniforme de 0,5 mm e as com modificação apresentavam espessura de 0,5 mm acrescentadas da cinta lingual de 2,0 mm de altura e postes proximais com 3,5 mm de altura, ambos com 1 mm de espessura. As coroas foram cimentadas com cimento resinoso (Rely X ARC) sobre réplicas de resina composta do preparo. Estas coroas foram submetidas ao teste de resistência à fadiga por meio da ciclagem dinâmica em água (106 ciclos ou até a fratura com carga variando de 30-300 N). Um endentador de aço inoxidável aplicava a carga axialmente entre as duas vertentes linguais e vestibulares. A ciclagem era interrompida em intervalos de 125 mil ciclos a procura de danos com auxílio de estereomicroscopia. Ao final, as coroas fraturadas eram submetidas a microscopia eletrônica de varredura e as não fraturadas eram incluídas em resina epóxi e polidas sequencialmente para a análise dos danos. Cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. Utilizou-se o teste Kruskal-Wallis para verificar diferença estatística entre os grupos e o de Miller para as comparações múltiplas entre os grupos. Os resultados não indicaram diferença estatística entre os desenhos de infraestrutura, entretanto o resfriamento lento mostrou-se significativamente melhor na prevenção dos danos / The exceptional mechanical proprieties such as high flexural strength and fracture toughness make Zirconia anatural choice as material for posterior dental prosthesis. However, even with these properties, problems related to fracture persist. Low heat conductibility of zirconia and lack of support for veneering porcelain may be pointed as possible causes. The proposed study investigate if modifications on core design and cooling rate protocol during glaze firing are able to improve allceramic zirconia reinforced crows resistance. Forty molar zirconia reinforced single crowns (IPS e.max ZirCAD) were manufactured from standard abutment and divided in four groups: ZrCRP (conventional core design and standard cooling rates), ZrMRP (modified core design and standard cooling rates), ZrCRL (conventional core design and slow cooling rates) e ZrMRL (modified core design and slow cooling rates) (Até aqui ta bem escrito). The standards design Cores presented uniform thickness of 0,5 mm and the modified design Cores consisted of 0.5 mm thickness with a thick lingual margin of 2.0mm height, connecting to full contour proximal struts of 3.5 mm height, remembering that both the standard and the modified Core possess 1 mm of thick. Crows were luted with resin cement (Rely X ARC) on composite resin abutment replicas. These crowns were then subjected to motion fatigue in water (106 cycles or till fracture with 30-300 N varying load). A stainless steel indenter was used to perform axial load between buccal and lingual cusps. Mechanical cycling was interrupted at each 125000 cycles for damage investigation in a stereomicroscope. Fractured crows were submitted to scanning electron microscopy and not-fractured crowns were included in epoxy resin, longitudinally sectioned and sequentially polished for damage analysis. Each crown received scores according to the type of failure. Statistical analysis was carried out with Kruskal-Wallis test and multiple comparisons between groups were carried out with Millers test. Results did not show significant differences between infrastructure design, however low cooling rates statistically better results on damage prevention than standard cooling rates.
69

Influencia de agentes cimentantes na resistencia a tração de coroas totais fundidas, fixadas em dentina e nucleos metalicos

Prates, Luiz Henrique Maykot 14 September 1999 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T17:22:10Z (GMT). No. of bitstreams: 1 Prates_LuizHenriqueMaykot_M.pdf: 4937964 bytes, checksum: 1759111268df7345a8f2609a47b24c1d (MD5) Previous issue date: 1999 / Resumo: O propósito do estudo foi avaliar o comportamento de 4 agentes cimentantes, em relação à resistência à remoção, por tração, de coroas totais fundidas, fixadas sobre preparos em dentina e núcleos metálicos. Foram utilizados 28 molares humanos, inferiores e recém-extraídos. Após a confecção de um orifício retentivo, as raízes dos dentes foram embutidas em resina acrílica ativada quimicamente, contida em tubos de PVC. Nas porções coronárias foram confeccionados preparos para coroas totais, com ponta diamantada n. 4103, sob refrigeração, acoplada ao torno mecânico. Os preparos em dentina, com expulsividade de 8°, foram reproduzidos em liga de prata Pratalloy (Degussa), através de técnica de fundição. Após a limpeza dos núcleos metálicos, com jato de óxido de alumínio, os preparos foram moldados com silicona por adição Express (3M), sendo o enceramento os padrões das coroas, realizado em troquéis de gesso tipo IV Vel Mix (Kerr). As 56 coroas totais, com uma alça suporte oclusal, foram confeccionadas em liga de paládio-prata Pors-on 4 (Degussa), através de técnica de fundição de rotina. Após a limpeza das coroas, com jato de óxido de alumínio, os corpos-de-prova em dentina e em núcleos, foram divididos aleatoriamente em 8 grupos com 7 réplicas (4 grupos em dentina e 4 em núcleos). As coroas dos grupos 1,2, 3 e 4 foram fixadas nos preparos em dentina, respectivamente, com os cimentos de fosfato de zinco (Cimento de Zinco - SS White); de ionômero de vidro convencional (Ketac Cem - ESPE); de ionômero de vidro modificado por resina (Vitremer - 3M); e, resinoso com adesivo (Cimento de Resina com Scotchbond Multi-Uso Plus - 3M). As coroas dos grupos 5, 6, 7 e 8 foram fixadas nos núcleos metálicos, respectivamente, com os mesmos cimentos. Os corpos-de-prova foram armazenados em 100 % de umidade relativa, a 37° C, durante 24 horas, sendo em seguida submetidos a 500 ciclos. ... Observação: O resumo, na integra, poderá ser visualizado no texto completo da tese digital / Abstract: The purpose of this study was to evaluate the behaviour of 4 dental cements, to the removal strength, under tensile, of full cast crowns luted to dentin, and cast metallic cores. Atier the preparation of a retentive orifices, the roots of twenty eight teeth were embedded in resin within PVC tubes. Then, the coronal portions of the teeth were prepared to receive full crowns, using a 4103 diamond bur, under refrigeration, held on a lathe. Dentin preparations, with 8 degrees of tapering, were duplicated with silver alloy (Pratalloy - Degussa), using a routine casting technique. The mettalic cores were cleaned with aluminum oxide blast, the preparations were cast with Express (3M) vinyl polysiloxane, and the patterns were waxed on type IV stone dies (Vel Mix - Kerr). The fifiy six full crowns, with an occlusal support loop, were ma de with palladium-silver alloy (Pors-on 4 - Degussa) using a routine casting technique. The mettalic crowns were cleaned with aluminum oxide blast, and then the test specimens on dentin and in cores were randomly assigned to 8 groups of 7 units each (4 groups in dentin and 4 groups in cores). The crowns of Groups 1, 2, 3 and 4 were luted to the preparations in dentin, respectively, with zinc phosphate (SS White), conventional glass ionomer (Ketac Cem ESPE), resin-modified glass ionomer (Vitremer - 3M) and resin with adhesive (Resin cement and Scotchbond MP Plus - 3M) cements. The crowns of Groups 5, 6, 7 and 8 were luted in metallic cores, respectively, with the same cements. All samples were stored at 370 C, in 100 % relative humidity, for 24 hours. ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Materiais Dentários
70

Influência da espessura da cerâmica no comportamento biomecânico, sobrevivência e na translucidez de coroas monolíticas /

Dal Piva, Amanda Maria de Oliveira. January 2020 (has links)
Orientador: Marco Antonio [Unesp] Bottino / Resumo: Apesar do aumento do uso de coroas monolíticas, seu desempenho, em diferentes aspectos, ainda não foi determinado. Inicialmente, este projeto investigou o comportamento biomecânico de diferentes coroas monolíticas convencionais sobre dentes e a distribuição de tensões na camada de cimento (Artigo 1). Como objetivo principal, este estudo avaliou o efeito do princípio do mínimo preparo dental no comportamento biomecânico, confiabilidade e translucidez de coroas monolíticas posteriores em cerâmica. No entanto, para definir o substrato a ser utilizado para receber as coroas usinadas, uma análise complementar foi desenvolvida para observar o comportamento da restauração sobre diferentes substratos através da análise por elementos finitos (Artigo 2). E para o Artigo 3, cento e vinte e seis coroas foram fabricadas e divididas (n = 21 / gr) de acordo com o material (zircônia de alta translucidez -YZHT, silicato de lítio reforçado com zircônia - ZLS e cerâmica híbrida -HC) e espessura (0,5 – subgrupo .5 ou 1 mm – subgrupo 1). A concentração de tensão de tração foi calculada pelo método dos elementos finitos, as coroas adesivamente cimentadas foram fadigadas pelo teste step-stress para calcular a confiabilidade de missões a 600 e 900 N a 100.000 ciclos; e, a translucidez foi analisada em 10 discos de cada material e espessura. Maior concentração de tensão de tração foi observada em coroas mais finas e com módulo de elasticidade mais alto. As coroas YZHT foram suspensas quando a fadiga ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor

Page generated in 0.0557 seconds