• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 752
  • 34
  • 12
  • 7
  • 7
  • 7
  • 7
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 809
  • 406
  • 221
  • 198
  • 194
  • 187
  • 139
  • 109
  • 108
  • 107
  • 107
  • 104
  • 97
  • 89
  • 83
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Programação de parada de plataforma marítima utilizando o método da corrente crítica. / Offshore platform shutdown using critical chain method.

Finocchio Junior, Jose 12 February 2009 (has links)
A presente dissertação investiga a adequação do método da Corrente Crítica para a programação dos projetos de parada de plataformas marítimas de exploração de petróleo, que envolvem processos de tomada de decisões em condições de risco. O método da Corrente Crítica (Critical Chain Project Management - CCPM), baseado na Teoria das Restrições (TOC), se propõe a oferecer instrumentos de controle mais precisos e focados que os tradicionalmente utilizados no método do Caminho Crítico (Critical Path Method - CPM), indicando em que momento agir, onde e como deve ser direcionada a ação. A hipótese subjacente à pesquisa é a de que a Corrente Crítica (CCPM) traduz, de forma mais adequada que o Caminho Crítico (CPM), a incerteza existente na parada de plataforma, permitindo a elaboração de um cronograma a um só tempo mais realista e mais desafiador, no sentido de atender metas de menor interrupção na produção. Com base nessa hipótese, as duas principais perguntas que nortearam toda a investigação foram: 1. O método da Corrente Crítica é adequado à programação da parada de plataformas marítimas de exploração de petróleo? 2. Que vantagens poderia trazer em comparação aos métodos tradicionais de programação de projetos em uso nas paradas de plataformas? Para responder a tais perguntas, além de revisar a bibliografia existente sobre o assunto, optou-se por coletar depoimentos de diversos especialistas do setor, por meio de três abordagens qualitativas: pesquisa-ação, entrevistas semi-estruturadas e grupo focal. A análise e interpretação dos dados revelaram que, devido aos seus instrumentos de controle de restrição de recursos serem mais afinados, o Método da Corrente Crítica (CCPM) é mais adequado ao problema da parada de plataformas marítimas - caracterizado pelo ambiente de alta limitação de recursos e por grande paralelismo de atividades. O presente estudo leva a concluir que a implantação do novo método, por oferecer aos gestores ferramentas mais precisas de controle, resulta em melhores chances de cumprimento do prazo dos projetos. / The present study discusses the adequacy of the Critical Chain Project Management Method (CCPM) - also known as the Critical Chain Method - for scheduling projects involving shutdowns on oil platforms, as such projects involve decision-making processes under risk conditions. The CCPM is based on the Theory of Constraints and aims at providing more precise and more clearly focused control instruments than those traditionally used in the Critical Path Method (CPM). The CCPM also indicates the best moments to act and where and how the action should be directed. The hypothesis underlying the research is that the CCPM portrays, more adequately than the CPM, the uncertainty that exists in a platform shutdown. This characteristic also makes it possible to draw up a schedule that is both more realistic and more challenging, as it addresses the goal of causing less interruption of production. On the basis of this hypothesis, the two main questions that oriented the entire investigation were: 1) Is the CCPM suitable for scheduling the shutdown of an offshore oil platform and, 2) What advantages might it have over the traditional scheduling methods in use on platform shutdown? To answer these questions the authors reviewed the existing bibliography on the topic and made direct on-site observations during an actual shutdown. In addition, interviews were held with a number of specialists in the area using qualitative approaches, namely, semi-structured interviews, focus groups, and action research. The Data analysis revealed that the instruments used in the CCPM for controlling the constraints of resources are more refined, so the method has been proven to be more adequate than others for facing problems that come up in offshore platform shutdowns, which are characterized by strict constraints on resources and considerable parallelism of activities. The results have led to the conclusion that the implementation of the CCPM provides managers with more precise tools for control than the CPM, and may thus increase the chances for complying with the timeframes set down for projects.
192

Influência de centros de captura na relaxação dielétrica de cristais de Ki:M++. / The influence of capture centers on the dielectric relaxation of Ki:M ++.

Zilio, Sergio Carlos 16 August 1976 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl&#8254.Os novos picos de relaxação, atribuídos à presença do Cl&#8254 na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente.Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl&#8254 e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl&#8254.The new relaxation peak attributed to the presence of the Cl&#8254 in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one.A model for the trapping of the divalent ions by the Cl&#8254 is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
193

Determinação da polarização ferroelétrica do PVDF estirado biaxialmente utilizando a técnica de corrente constante. / Determination of the biaxially stretched PVDF ferroelectric polarization using constant current technique.

Moura, Walterley Araujo 22 July 1998 (has links)
Foi desenvolvido um novo método para a determinação da polarização ferroelétrica de polímeros ferroelétricos, em particular do PVDF estirado biaxialmente. A técnica consiste em manter constante a corrente através da amostra e medir a evolução da tensão (V versus t) entre os eletrodos da mesma. As medidas foram realizadas em ambiente com atmosfera de ar superseco o que permite desprezar a condução elétrica das amostras, simplificando sobremaneira as equações do problema. Considera-se a existência de dois tipos de polarização: a ferroelétrica, com tempo de chavamento desprezível, e uma polarização elétrica foram realizados em duas situações distintas: com chaveamento e sem chaveamento ferroelétrico. O procedimento permite avaliar a dependência da polarização ferroelétrica com o campo, determinada a partir da equação geral da corrente. Para se descrever a resposta da polarização elétrica dependente do tempo, usa-se o princípio da superposição e assume-se que ela está em fase com o campo elétrico aplicado (processo lento). Será mostrado que é possível determinar a polarização ferroelétrica do polímero PVDF estirado biaxialmente sem a necessidade de determinar a formas funcionais da polarização dependente do tempo e de se conhecer o valor da capacitância da amostra. / In this work a novel method was developed for the determination of the ferroelectric polarization of ferroelectric polymers, in particular of biaxially stretched PVDF. The technique consists of maintaining constant the current through the sample and to measure the evolution of the bias voltage (V versus t) on the electrodes. Measurements were performed in super-dry air, which allows one to neglect the electric surface and volumetric conduction of the samples, simplifying the equations of the problem. It is considered the existence of two polarization types: the ferroelectric, with a very short switching time, and a another polarization dependent of the time. The processes for studying the electric polarization were accomplished in two different situations: with switching and without ferroelectric switching. The procedure allows evaluating the dependence of the ferroelectric polarization on the electric field, determined starting from the general equation of the current. To describe the time dependent polarization it is used the principle of superposition and the polarization value assumed to be in phase with the applied electric field (slow process). It will be shown that it is possible to determine the ferroelectric polarization of the material without the need of the functional form of the polarization and the value of the capacitance of the sample.
194

Sistemas multiterminais de transmissão em corrente contínua: conversores tipo fonte de corrente. / Multiterminais direct current transmission systems: current source type converters.

Bassini, Marcos Tiago 10 March 2014 (has links)
Este trabalho aborda os sistemas multiterminais para transmissão em corrente contínua baseados em conversores do tipo fonte de corrente (CSC - current source converters). São apresentados resultados de estudo em um sistema multiterminal em corrente contínua (MTDC) de quatro terminais em três estações inserido no sistema norte-nordeste brasileiro, tendo como enfoque principal a sua modelagem, simulação e desempenho em relação à estabilidade durante transitórios eletromecânicos. O sistema é modelado nos programas PSCAD/EMTDC e EMTP-RV, com detalhe para a topologia, os controles e requisitos do MTDC. São também descritos e modelados os conversores a tiristores, as linhas em corrente contínua, bancos capacitivos para compensação de fator de potência, bem como os geradores síncronos e seus reguladores. O desempenho do sistema é avaliado por meio de simulações de inicialização, de regime permanente e transitória diante de contingências. Com isso, esta pesquisa contribui para a compreensão do desempenho de sistemas MTDC e para a criação de modelos para inserção nos programas de transitórios eletromecânicos. / This work addresses the CSC-based, multiterminal solution for DC transmission. The focus of the study was to analyze a four-terminal three-station MTDC scheme inserted in the Brazilian north-northeast power system through modeling, simulation and evaluation of performance regarding stability during electromechanical transients. The system is modeled in PSCAD/EMTDC and EMTP-RV programs, with special detail in the MTDC topology, controls and technical/operative requirements. It is also described the thyristor-based converters, the DC lines, capacitor banks for power factor compensation, as well as the synchronous generators and their regulators. The system performance is evaluated through simulation of converter initialization, steady state response and transient response after contingencies. Thus, this research not only contributes to the understanding of the performance and operation of MTDC systems, but it also assists the development of MTDC models for electromechanical transient programs.
195

Características de escoamentos decorrentes de diferenças de densidades / Characteristics of flows due density differences

Silva, Selma Vargas da 19 December 2002 (has links)
Neste trabalho analisam-se escoamentos de correntes de densidade tipo plumas, intrusões e corrente de fundo em torno de obstáculos. Os experimentos foram realizados em duas fases. Na primeira fase dos ensaios, a estratificação ambiente e a obtenção das correntes foram obtidas variando-se a densidade de soluções de água e sal. A visualização das correntes foi feita utilizando-se permanganato de potássio e sua dispersão foi obtida através do registro em câmera filmadora. Na segunda fase, os ensaios de plumas foram realizados com equipamento a laser de vapor de cobre (LVC) envolvendo o método de velocimetria a laser por processamento de imagens (VLPI). Nesta fase, observou-se grande dificuldade na visualização das partículas do escoamento e foi necessário a confecção de um sistema de aquecimento de água para a obtenção do escoamento superficial. É apresentado um modelo numérico em linguagem FORTRAN baseado no método das diferenças finitas para discretização da equação de Navier-Stokes e a obtenção de velocidades longitudinais e transversais. Observou-se, neste trabalho, a importância da visualização do fenômeno de correntes superficiais e intrusivas, tendo em vista a extrema sensibilidade destes fenômenos para com as condições de trabalho (alterações sutis geram grandes diferenças no escoamento obtido). Pode-se concluir que o método VLPI produz resultados satisfatórios para o campo de vetores de velocidade. As correntes intrusivas apresentaram configurações diversas para mesmas condições de escoamento, o que demonstra a necessidade de maiores estudos. O modelo numérico se mostrou coerente para determinados experimentos, mas as condições particulares da entrada dos reservatórios mostra que há a necessidade de implementações para uma forma mais abrangente de situações. / Unstable gravity currents flows like buoyant surface jet (BSJ), intrusions and dense currents around obstacles are analysed in this research. The experiments were performed in two phases. In the first one, the environmental stratification as well as the current flows were obtained varying the density of the water and salt solutions. The current visualization were possible by the use of the KMnO4 dye and its dispersion was recorded by video camera. In the second phase, the runs with plumes were evaluated with a laser vapour copper (LVC) equipment using the processing image velocimetry (PIV) method. In this phase, it was observed a great difficulty in the particle flow visualization and it was necessary a war water system to simulate overflow. It\'s presented a numerical model in fortran language based in the finit difference method to discretisize the Navier-Stokes equation and obtain the transversal and longitudinal velocities. It was noted in this research, the relevance of the visualization in overflows and intrusive flows because of the extreme sensitivity of these phenomenos to work conditions (slightly modifications generates great differences in the flow behaviour). It concludes that the PIV method results good data for vectors velocity field. The intrusive currents show many configurations to the same flow conditions which requires further investigations. The numerical model has shown coherance to particular experiments, but source particularities justifies the necessity of implementation to larger situations.
196

Transdutor híbrido para medidas susceptométricas e ultrassônicas simultaneamente / Hybrid transducer for susceptométricas and ultrasonic measures simultaneously.

Bruno, Alexandre Colello 26 March 2010 (has links)
Este trabalho descreve a construção e caracterização de um novo transdutor dedicado às medições susceptométricas e ultrassônicas de amostras marcadas com partículas magnéticas. Este transdutor, denominado de magnetoacústico, consiste de um sistema híbrido formado pela junção de um Biossusceptômetro de Corrente Alternada (BCA) e um transdutor ultrassônico. Seu principio básico de funcionamento consiste na medida simultânea da magnetização de um meio material marcado com partículas magnéticas e das microvibrações da estrutura interna deste meio quando excitado por um campo magnético alternado externo gerado pelas próprias bobinas de excitação do BCA. Estudos in vitro foram realizados para auxiliar no desenvolvimento e caracterização do protótipo apresentado neste trabalho. A técnica de medida empregando este transdutor híbrido foi denominada de vibromagnetoacustografia. As amostras utilizadas consistiram de meios fluidos marcados com traçadores magnéticos (micropartículas de ferrita de tamanhos variando entre 30 m e 70 m de diâmetro). Foi avaliada a dependência da resposta do sistema com diferentes parâmetros físicos tais como: viscosidade do material base o qual foi misturado as partículas ferromagnéticas; concentração dessas partículas misturadas ao material base; frequência de oscilação do campo magnético de excitação; tensão nas bobinas de excitação e a distância entre a amostra e o transdutores. A resposta do transdutor magnetoacústico apresentou melhor relação sinal/ruído em torno de 200 Hz de frequência de magnetização, considerando uma concentração de 4% de ferrita. Acima desta concentração a viscosidade do material base era alterada e interferia na medida. As respostas do susceptômetro e do ultrassom Doppler contínuo possuem uma relação linear com o nível de tensão aplicada nas bobinas de excitação e uma dependência quase linear com baixas concentrações de partículas ferromagnéticas ( 4%). Também foi realizado um teste de repetibilidade no protótipo obtendo um desvio relativo de 0,94% e 0,25% nas medições Doppler e susceptométricas, respectivamente. A medida de vibração das micropartículas ferromagnéticas realizadas in vitro, usando um transdutor Doppler contínuo, apresentou alta sensibilidade para baixas concentrações de material ferromagnético inseridos em meio fluido (~ 1%). / This work describes the construction and characterization of a new transducer dedicated to the susceptometrics and ultrasonic measurements of samples labeled with magnetic particles. This transducer, called magneto-acoustic, consists of a hybrid system formed by the junction of an Alternating Current Biosusceptometer (ACB) and an ultrasonic transducer. Its basic operation principle is the simultaneous measurement of the magnetization and the internal structure micro-vibrations of a medium labeled with magnetic particles when excited by an external alternating magnetic field generated by the ACB excitation coils. In vitro measurements were performed to support the prototype development and characterization presented in this work. The measurement technique employing this hybrid transducer was called vibromagnetoacoustography. The samples consisted of fluid medium labeled with magnetic tracers (ferrite micro particles of diameter ranging from 30 m and 70 m). It was evaluated the system response dependence with different physical parameters such as: base material viscosity in which ferromagnetic particles was mixed; the particles concentration in the base material; the oscillation frequency of the magnetic field excitation; the voltage applied on magnetizing coils and the distance between sample and transducers. The magneto-acoustic transducer response showed a better signal to noise ratio for magnetization frequency around 200 Hz and a 4% ferrite concentration. Above this concentration the base material viscosity changed disrupting the measurements. The responses of susceptometer and Doppler ultrasound have a linear dependence with the applied voltage level in the magnetizing coils and an quasi linear dependence with low ferromagnetic particles concentrations (4%). A repeatability test was also performed to the prototype which indicated a deviation of 0.94% and 0.25% in the Doppler and susceptometric measurements, respectively. The vibration measurement of ferromagnetic micro-particles performed in vitro, using a Doppler transducer, showed high sensitivity to low ferromagnetic material concentrations (~1%) immersed in a fluid medium.
197

Impacto do uso de conectores sem agulha para sistema fechado de infusão na ocorrência de infecção de corrente sanguínea relacionada ao cateter venoso central: evidências de uma revisão sistemática / Impact of needleless connectors in closed infusion systems on the occurrence of bloodstream infection related to the use of central venous catheters: evidence from a systematic review

Mendonça, Silvia Helena Frota 29 April 2008 (has links)
Os conectores sem agulhas foram introduzidos para redução de incidência de acidentes pérfuro-cortantes nos profissionais da área da saúde e a literatura apresenta evidências irrefutáveis sobre este aspecto. No entanto, não há evidências conclusivas sobre as vantagens do conector sem agulha para o paciente, no que se referem aos índices de infecção de corrente sanguínea relacionada ao cateter venoso central. Este estudo tem como objetivo evidenciar o impacto do uso de conectores sem agulhas para sistema fechado de infusão na ocorrência de infecção de corrente sanguínea relacionada ao cateter venoso central por meio de revisão sistemática, desenvolvida conforme as recomendações propostas pela Colaboração Cochrane. A estratégia de busca nas bases de dados eletrônicas utilizou os componentes do PICO: População (estudos com pacientes em uso de cateter venoso central, independente de idade, sexo, etnia e serviço de saúde vinculado); Intervenção (uso de conectores de sistema fechado sem agulhas, não-valvulados, valvulados, com pressão positiva ou não); Comparação (uso de oclusores, conectores de sistema fechado com ou sem agulhas, não-valvulados, valvulados, com pressão positiva ou não); Outcome-desfecho (infecção de corrente sanguínea, contaminação do canhão, contaminação microbiana, infecção de corrente sanguínea relacionada ao cateter). As bases eletrônicas investigadas foram: PubMEDLINE, OVID, EMBASE, LILACS, CINAHL. Também foram avaliadas as referências bibliográficas dos estudos incluídos. Os resultados estão apresentados em três etapas: caracterização do processo de seleção dos estudos encontrados na busca; caracterização dos estudos incluídos para a revisão sistemática (RS); avaliação de qualidade e força da evidência dos estudos incluídos segundo a Escala de Jadad e a Escala de avaliação de qualidade dos estudos na área de Controle e Prevenção de Infecção de Corrente Sanguínea Relacionada ao cateter Venoso Central. A amostra desta revisão sistemática constitui-se de 14 estudos, e quatro investigaram somente conectores sem agulhas. Foram encontrados 6 ensaios clínicos controlados randomizados, 4 coortes, 3 caso-controle e 1 resultado terapêutico. A infecção de corrente sanguínea relacionada ao cateter venoso central foi o desfecho de 9 estudos. Seis apresentaram diferenças a favor do conector valvulado; 04 a favor do conector puncionável com cânula; 01 a favor do conector puncionável com agulha; 01 a favor do conector valvulado com pressão positiva e 02 a favor do dispositivo usado antes da troca. A heterogeneidade dos estudos quanto aos desenhos de pesquisa, as características das populações e os fatores de riscos controlados e os resultados, não permitem a realização de meta-análise, contudo, é possível afirmar, com base nos quatro melhores estudos encontrados, que a implantação de conectores sem agulhas, quer valvulados ou com injetor pré-furado, com manutenção de sistema fechado de infusão, apresentam impacto positivo relacionado à menor contaminação do canhão do cateter ou na ocorrência de infecção de corrente sanguínea relacionada ao cateter venoso central / Needleless connectors were introduced to reduce the incidence of needlestick injuries in health professionals and according to the literature their effectiveness is irrefutable. However, there is no conclusive evidence on the advantages of needleless connectors for patients with regard to bloodstream infection rates from the use of central venous catheters. The objective of this study was to determine the impact of the use of needleless connectors in closed infusion systems on the occurrence of bloodstream infections related to the use of central venous catheters by conducting a Cochrane systematic review. The strategy for searching electronic databases employed the components of the PICO model: Population (studies of patients using central venous catheters, regardless of age, sex, race and associated health service); Intervention (use of closed needleless connector systems, with and without valves, with and without positive pressure); Comparison (use of plugs, closed system connectors with and without needles, with and without valves, with and without positive pressure); Outcome (bloodstream infection, cannula contamination, microbial contamination, bloodstream infection related to catheter). The electronic databases investigated were: PubMEDLINE, OVID, EMBASE, LILACS and CINAHL. Bibliographical references of the studies included were also evaluated. The results are presented in three stages: characterization of selection process for studies found in the search; characterization of studies included in the systematic revision; evaluation of quality and strength of evidence for studies included according to the Jadad Scale and the scale of quality of studies in the control and prevention of bloodstream infections related to central venous catheters. The sample of this systematic review was made up of 14 studies of which 4 investigated only needleless connectors. We found 6 randomized control clinical trials, 4 cohort, 3 case-control and 1 therapeutic result. Bloodstream infection related to central venous catheters was the outcome for 9 studies. Six presented differences regarding the valved connector; 04 in favor of the puncturable connector with cannula; 01 in favor of the puncturable connector with needle; 01 in favor of the valved connector with positive pressure and 02 in favor of the device used before the change. The heterogeneous nature of the studies with regard to design, population characteristics and controlled risk factors and results prevented a meta-analysis. However, it is possible to state, based on the four best studies found, that the introduction of needleless connectors, whether valved or puncturable with cannula, coupled with a closed infusion system, presented a positive impact on lowering contamination of catheter cannulae and on the occurrence of bloodstream infection related to central venous catheters
198

Distribuição ecológica e estrutura populacional em escala espacial, temporal e anual do camarão-branco Litopenaeus schmitti (Burkenroad, 1936) (Dendrobranchiata: Penaeidae) na enseada de Ubatuba : 4 anos de estudo /

Bochini, Gabriel Lucas. January 2012 (has links)
Orientador: Rogério Caetano da Costa / Banca: Antonio Leão Castilho / Banca: Jandira Liria Biscalquini Talamoni / Resumo: O presente estudo foi dividido em dois capítulos e tiveram como objetivos: cap.1- verificar a distribuição espaço-temporal de L. schmitti em três baías do litoral norte do estado de São Paulo, Ubatumirim (UBM), Ubatuba (UBA) e Mar Virado (MV); testar a relação dos fatores ambientais com a distribuição dos camarões durante um período de 2 anos (1998 e 1999) e cap. 2- averiguar a variação anual e sazonal da biomassa e do número de indivíduos do camarão, durante 4 anos de estudo (1998, 1999, 2002, 2006), com enfoque no período reprodutivo e de recrutamento juvenil informando qual a melhor época para a pesca. Os camarões foram capturados com um barco camaroneiro equipado com redes do tipo "double-rig" em profundidades até os 20 metros. Em 1998 e 1999, um total de 5658 indivíduos foi coletado, sendo 4437 no primeiro ano e 1221 no segundo ano. Em MV obteve-se a maior abundância (n= 2747), seguido de UBM (n= 1649) e UBA (n=1262). A salinidade da água variou de 28 a 37 com média de 34,6 ± 1,44, porém não houve correlação significativa desse fator com a abundância (p=0,90). A média da temperatura de fundo foi de 24,8 ± 2,84 °C com valor máximo de 31,4 °C e mínimo de 19 °C. Apesar dessa grande variação nos valores obtidos, não houve correlação significativa desse fator com a abundância (p= 0,11). A maior captura de camarões foi registrada em áreas onde silte + argila correspondem mais de 70 % do sedimento e em locais com maior porcentagem de matéria orgânica. Houve relação inversa da abundância com a pluviosidade, com as maiores abundâncias nos meses posteriores a temporada de chuvas. Porém, no ano em que houve maior pluviosidade, também houve uma maior captura de indivíduos. A quantidade de camarões seguiu uma tendência sazonal, sendo maior durante o outono e inverno... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study was divided in two chapters, which aimed: chapter 1 - to verify the spatiotemporal distribution of L. schmitti in three bays of north littoral of São Paulo State, Ubatumirim (UBM), Ubatuba (UBA) e Mar Virado (MV); to test the relation between environmental factors and shrimp distribution, during a 2-year period (1998 and 1999) and chapter 2 - to investigate the annual and seasonal variation of biomass and of the number of shrimp individuals, focusing reproductive period and juvenile recruitment; which is the best period for the open season; the rainfall influence on abundance during 4 years of study (1998, 1999, 2002 and 2006). Shrimps were captured with a shrimp fishing boat equipped with two double-rig nets at depths up to 20m. In 1998 and 1999, a total of 5658 individuals was collected, being 4437 on first year and 1221 on second year. The highest abundance was obtained at MV (n=2747), followed by UBM (n=1649) and then by UBA (n=1262). Water salinity has varied from 28 to 37, with average of 34.6 ± 1.44, although abundance has not had a significant correlation with this factor (p=0,90). The average bottom temperature was of 24,8 ± 2,84 °C, with a maximum of 31.4 °C and a minimum of 19°C. Besides the great variation on these values, abundance has not had a significant correlation with this factor (p=0.11). The higher shrimp capture was registered in areas where sediment was composed by more than 70% of silt + clay and at areas with highest percentage of organic-matter. There was an inverse correlation between abundance and rainfall, with the highest abundances on months after the rainy season. However, the highest individual catch occurred in the year with highest rainfall rates. Shrimp amount had a seasonal tendency, being higher during autumn and winter in both years. A total of 566 (13,171 g) individuals... (Complete abstract click electronic access below) / Mestre
199

Processos de instabilidade barotrópica da Corrente do Brasil na Bacia de Santos / Barotropic instability process of Brazil current at Santos Basin

Pereira, Diogo Peregrino Corrêa 14 August 2009 (has links)
A Corrente do Brasil é formada na bifurcação do ramo sul da Corrente Sul Equatorial e flui meridionalmente para sul ao largo das costas leste, sudeste e sul do Brasil, apresentando intensa atividade de mesoescala entre a Cadeia Vitória-Trindade (20oS) e o Cabo de Santa Marta Grande (28oS). O conhecimento de tal atividade, construído ao longo do tempo, se refere principalmente aos meandros e vórtices frontais, sendo os vórtices de borda na configuração de dipolos vorticais relatados apenas através de imagens AVHRR. Dessa forma, objetivamos caracterizar a estrutura dinâmica de um dipolo vortical, observado na Bacia de Santos, a partir de dados quase-sinóticos de velocidade e hidrográficos oriundos do Cruzeiro Dinâmica do Ecossistema da Plataforma da Região Oeste do Atlântico Sul V. O mapeamento objetivo das estruturas capturadas pela grade amostral quase-sinótica do cruzeiro foi o ponto de partida para a descrição do dipolo e avaliação de sua geostrofia. Os campos de função de corrente apresentaram um padrão clássico de dipolo vortical, com vórtices ciclônico e anticiclônico posicionados em lados opostos ao eixo da corrente, que se enfraquece após a estrutura. Em média, o diâmetro de ambos os vórtices ficou em torno de 110 km, em seus maiores eixos. Em seguida, como o número de Rossby máximo foi de 0,27, para avançar nas questões dinâmicas envolvendo a estrutura, aproximamos o oceano a um modelo quase-geostrófico de 11/2-camadas derivado das observações e dinamicamente calibrado. A análise dos campos modelados, utilizando o número de Burger, revelou que a vorticidade relativa compete com a vorticidade de estiramento pela dinâmica do sistema. Ao compararmos os campos modelados de função de corrente e vorticidade potencial, observamos que o dipolo e o escoamento da CB não se encontram em um cenário estacionário. Finalmente, evidências de retroalimentação mútua entre os vórtices do dipolo foram obtidas através da interação entre o campo de função de corrente de uma estrutura com o campo de vorticidade potencial da outra. Logo, concluímos que o dipolo capturado encontrava-se em processo de crescimento barotrópico. / The Brazil Current (BC) is formed at the bifurcation of the southern branch of the South Equatorial Current and flows south-southeastward off the east, southeast and southern Brazilian continental margin, exhibiting intense meso-scale activity between the Vitória-Trindade Ridge (20oS) and Cape Santa Marta Grande (28oS). The knowledge of such activity, built over time, refers mainly to the frontal meanders and eddies. The edge vortical structures as a dipole configuration are reported only through AVHRR images. Thus, we aimed to characterize the dynamical structure of a BC vortical dipole, observed in the Santos Basin, with a quasi-synoptic velocity (vessel-mounted ADCP) and hydrographic (CTD) dataset from DEPROAS V cruise. The objective mapping of structures captured by the cruise sampling grid was the departing point for the description of the dipole and evaluation of its degree of geostrophy. The fields of the stream function showed a classic pattern of a dipole with cyclonic and anticyclonic eddies positioned on opposite sides of the current axis. On average, the diameter of the two eddies was around 110 km in their largest axes. Then, as the Rossby number was 0.27, we advanced in investigating the issues involving the dynamic structure by we approximating the ocean to a 11/2 layer quasi-geostrofic model derived from the observations and dynamically calibrated. Burger number revealed that both relative and stretching vorticity were competing for the dynamics of the system. The comparison between the modeled stream function and potential vorticity fields showed that both the dipole and the BC flow were not in a stationary state. Finally, evidences of reinforcement between the eddies of the dipole were obtained through the interaction between the field of the stream function of vortical structure with the field of potential vorticity of the other one, and vice-versa. Therefore, we conclude that the dipole were in a barotropic growth process.
200

Estudo do comportamento elétrico de filmes de PVDF na fase alfa / Electric behavior of alfa phase PVDF films

Costa, Mauro Miguel 22 March 1991 (has links)
A técnica do triodo de corona com corrente constante foi utilizada para carregar amostras de PVDF na fase &#945, acompanhando a evolução do potencial de superfície durante o carregamento. Com essa técnica foi possível não só obter a fase &#945p a partir da fase &#945 como também analisar o comportamento elétrico de ambas as fases. Os resultados obtidos em ambiente úmido mostram que a forma geral das curvas de potencial nas amostras carregadas com corona positiva e negativa são similares, ou seja, no início do carregamento tem-se um salto inicial, continua crescendo numa taxa mais lenta até alcançar um valor máximo de potencial e a partir deste valor decai para um regime estacionário. Os valores de potenciais alcançados na superfície da amostra não foram suficientes para gerar campos elétricos da ordem 1.5MV/cm, requeridos para induzir uma transição para a fase &#945p. Apesar de ocorrerem mudanças no comportamento elétrico durante os carregamentos, nenhuma mudança na estrutura das amostras foi detectada, usando a técnica de difratometria de raios-X. Em ambiente seco foi verificado que, durante o carregamento, o potencial na superfície da amostra alcançava valores altos quando comparado aos obtidos em ambiente úmido. Verificou-se também, que as amostras apresentavam enrugamento, característicos de materiais poliméricos. As mudanças ocorridas devido ao carregamento foram detectadas pela técnica de raios-X, confirmando a mudança de estrutura para &#945p. O comportamento ferroelétrico das amostras na fase &#945p, foi identificado pela curva de evolução do potencial de superfície, onde se avalia a quantidade de polarização ferroelétrica adquirida. As mudanças de estrutura e das propriedades elétricas em ambiente seco foram irreversíveis. / The constant current corona triode was used for charging &#945-PVDF samples and monitoring their surface potential buildup during poling. It is shown that the method allows one to obtain the polar &#945p form of PVDF from the non-polar &#945-form and also to analuse electrical characteristics of both forms. The experimental results obtained with samples under humid conditions show a similar behavior for positive and negative corona. There is na initial steep increase in the surface potential which then increases passing through a maximum value, and decreases until a steady state is reached. The maximum values attained are not sufficiently high to attain electric fields of around 1.5MV/cm required for causing a phase change from &#945 to &#945p. Furthermore, no change in the structure of the samples is noted in X-ray diffractograms. For measurments carried out under dry conditions, on the other hand, the sample surface potential attain much higher values. The samples become wrinkled after being submitted to these high electric fields (&#62 1.5MV/cm), and this is characteristic of ferroelectric materials. The change to &#945p from samples is confirmed by the structural changes exhibited in X-ray diffractograms. The ferroelectric behavior of the &#945p samples is further identified by the surface potential buildup, from which the remanent polarization can be inferred. The structural as well as the electric changes caused by the corona charging are found to be irreversible.

Page generated in 0.1051 seconds