• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1392
  • 17
  • 16
  • 15
  • 15
  • 15
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 1431
  • 690
  • 469
  • 306
  • 241
  • 205
  • 197
  • 185
  • 166
  • 158
  • 122
  • 121
  • 116
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Obtenção e caracterização de revestimento hidrofóbico utilizando viniltrietoxisilano (VTES) como precursor em solução sol-gel sobre aço inoxidável AISI 204 por dip-coating

Sacilotto, Daiana Guerra January 2015 (has links)
Filmes hidrofóbicos são caracterizados por repelir soluções aquosas quando em contato com superfícies revestidas ou com algum material que possua propriedades hidrofóbicas. Estes materiais têm despertado a atenção tecnológica devido às propriedades de: auto-limpeza, anti-gelo, anti-aderente e anti-corrosão. Este trabalho teve como objetivo a obtenção do filme hidrofóbico, em temperatura ambiente, utilizando o silano viniltrietoxisilano (VTES) sobre chapas de aço inoxidável AISI 204 em solução sol-gel pelo processo de dip-coating, tendo como finalidade o aumento da resistência à corrosão do substrato metálico. Para a reação de hidrólise foi preparada uma solução com relação percentual de silano/etanol/água de 4/48/48% em volume. Alguns parâmetros da solução e da superfície do substrato foram variados, tais como o tempo de hidrólise do silano na solução sol, em 2 e 24 horas, e a rugosidade do substrato pelo processo de jateamento com micropartículas de óxido de alumina comparando-o com o substrato liso (sem modificações). O filme foi caracterizado por microscopia eletrônica de varredura (MEV), ângulo de contato (CA), espectroscopia no infravermelho por transformada de Fourier (FTIR), espectroscopia de impedância eletroquímica (EIE), polarização potenciodinâmica, espectroscopia de energia dispersiva de raios-x (EDS), névoa salina e câmara úmida. Através destas técnicas de caracterização, pode-se avaliar a resistência à corrosão, a homogeneidade e a hidrofobicidade do filme obtido. Os resultados da influência do tempo de hidrólise demonstram que a solução de 24 horas proporciona um aumento na hidrofobicidade do filme de 12° em relação à solução de 2 horas de hidrólise. Enquanto que, a modificação da superfície com o jateamento favorece um aumento de 36° no ângulo de contato em relação à superfície lisa. Os ensaios eletroquímicos mostram que o substrato que possui maior ângulo de contato, 130°, apresenta maior resistência a corrosão comparando-o com as outras amostras, as quais apresentam ângulos de contato menores. Porém, os resultados de névoa salina comprovam que as amostras com a superfície lisa, ângulo de contato de 90°, possuem maior durabilidade do que as amostras jateadas quando expostas a ambientes salinos. Conclui-se que a metodologia utilizada é eficaz para a obtenção de revestimentos hidrofóbicos e para a proteção do metal base contra à corrosão. / Hydrophobic films are characterized to repel water or aqueous solutions when in interaction with coated surfaces or any materials with hydrophobic properties. These materials have attracted attention due the technological properties, like: self-cleaning, anti-icing, anti-adherent and anti-corrosion. This study aimed to obtain the hydrophobic film at room temperature using the vinyltriethoxysilane (VTES) on stainless steel AISI 204 in sol-gel solution by dip-coating process, with the purpose to increase the corrosion resistance of metal substrate. The hydrolysis reaction was prepared a solution with a percentage ratio of silane/ethanol/water 4/48/48% in volume. Some parameters of the solution and the substrate surface were varied, such as silane hydrolysis time in the sol solution at 2 and 24 hours, and the roughness of the substrate by blasting process with microparticles of aluminum oxide and it was compared with the smooth substrate (unchanged). The film was characterized by scanning electron microscopy (SEM), contact angle (CA), infrared spectroscopy by Fourier Transform (FTIR), electrochemical impedance spectroscopy (EIS), potentiodynamic polarization, energy dispersive spectroscopy (EDS), salt spray and humid room tests. Through these characterization was possible to evaluate the corrosion resistance, uniformity and hydrophobicity of the film developed. The influence of hydrolysis time showed an increase in contact angle of 12° when used the 24 hours of hydrolysis solution in relation to 2 hours of hydrolysis. While the surface modification using the blasting tecnique favors an increase of 36° in contact angle in comparison to the smooth surface. Between the samples evaluated by electrochemical spectroscopy, proves the higher contact angle, 130°, has best performance in corrosion resistance compared with another samples studied which have lower contact angles. However, the smooth substrate, contact angle 90°, showed the best performance in salt spray test compared to rough surfaces samples. The methodology developed was effective to obtain hydrophobic coatings and protection the metal substrate against the corrosion.
222

Determinação do potencial de agressão dos sais marinhos sobre as argamassas de revestimento na região metropolitana de Salvador / Evaluation of the aggressive potential due to marine salts on mortars used for rendering in the metropolitan region of Salvador, Bahia

Costa, Eduardo Antonio Lima January 2001 (has links)
Atualmente, é crescente a preocupação com relação à vida útil das edificações e com o desempenho dos materiais à agressividade do ambiente. Neste sentido, o estudo do potencial de agressão dos sais marinhos sobre as argamassas de revestimento é crítico. A presença de sais, e a conseqüente pressão de cristalização, são responsáveis por um grande número de manifestações patológicas nos revestimentos de edificações. O controle deste fenômeno se constitui em um fator importante devido, principalmente, aos elevados recursos financeiros necessários para recuperação do patrimônio atingido. O presente trabalho teve por objetivo avaliar o perfil da distribuição espacial dos sais marinhos com relação à distância do mar, através da determinação da taxa de deposição de cloretos, sulfatos e nitratos em sensores de vela úmida posicionados em estações de monitoramento localizadas nos municípios de Salvador, Lauro de Freitas e Camaçari (Região Metropolitana de Salvador). Adicionalmente, foram avaliadas as concentrações de cloretos e sulfatos que efetivamente penetraram, após um processo de deposição e migração, em corpos-de-prova de três tipos de argamassa, com consumos de cimento diferentes. Estes foram moldados com a adição de um argilomineral, localmente denominado de arenoso, visando analisar o comportamento de materiais típicos, pois o arenoso é freqüentemente utilizado em argamassas na região monitorada, mas não foi ainda devidamente estudado. A metodologia empregada permitiu avaliar a eficiência do equipamento de coleta e o desempenho comparativo, quanto à resistência à penetração de sais, dos traços de argamassa estudados. Foram determinados tanto os teores de sais depositados no sensor quanto os migrados para o interior da argamassa por cromatografia iônica. Os resultados foram analisados com relação à distância do mar. É possível concluir que, traços de argamassa com consumos de cimento em torno de 200 kg por metro cubico tem um melhor desempenho com relação a traços mais pobres, de menor consumo de cimento por metro cubico, quanto ao teor de sais efetivamente penetrado, e ainda, que o potencial de distribuição espacial do spray marinho é de maior influencia até 500 metros de distância do mar. A partir desta distância o teor de cloretos cai significativamente e, no caso dos sulfatos, outras fontes de emissões, como veiculares, passam a ser mais importantes como origem desses íons do que o spray marinho. / In recent years, there has been growing interest on the determination of the performance of materials and on the evaluation of the service life of constructions exposed to various environmental actions. In this sense, the determination of the aggressive potential of marine salts on mortars used as external renderings is critical. The presence of salts, and the associated crystallization pressures generated when the water is lost, are frequently responsible for the rapid deterioration of the material, due to tension cracking and spalling. The control and prevention of this deterioration mechanism is important, due to the large monetary resources necessary to repair the affected buildings. The present work had for objective the evaluation of the spatial distribution profile of marine salts in relation to the distance from the sea, by means of the deposition rate of chlorides, sulfates and nitrates in wet candle sensors, located in nine monitoring stations spread on the metropolitan region of Salvador, including sites on the municipalities of Lauro de Freitas and Camaçari. In addition, the determination of salts which effectively penetrated, trough a process of deposition and migration, in three different types of mortars, with varying cement content, was conducted. These mortars were fabricated with the addition of a clayish mineral, locally abundant, denominated “arenoso”. This indigenous material is frequently used as a lime-replacement addition in the region, but has not been properly studied yet. The methodology proposed allowed the evaluation of the efficiency of the monitoring sensors, the measurement of the atmospheric aggressive potential and the determination of the comparative performance, in terms of resistance to salt penetration, of the three mortars tested. The type and amount of salts, both captured in solution and present in the powder samples extracted from the mortars, were determined by means of ionic chromatography. The results were analyzed in regard to the distance from the sea. It is possible to conclude that mortars made with a cement content higher than 200 kg per cubic meter have a better performance in terms of salt penetration compared to mortars with a lower cement content per cubic meter. Also the data collected showed that the aggressive potential of marine salts in the region is significant up to a distance of 500 m from the sea. From this point onwards the amount of chlorides drops sharply and, in the case of sulfates other air emission sources, such as vehicular emissions become more important than the marine spray.
223

Caracterização eletroquímica e microestrutural de aços inoxidáveis anodizados em soluções contendo oxalato de niobila e molibdato de sódio

Taveira, Luciano Vieceli January 2004 (has links)
O efeito de tratamentos anódicos sobre a resistência à corrosão em soluções de cloreto e sobre a morfologia, a estrutura e a composição de filmes de óxido em ligas AISI304 L e AISI316L foi investigado. Para tal, aços inoxidáveis AISI304 L e AISI316L foram anodizados a altas temperaturas em soluções de Na2Mo04, NH4H2NbO(C204)3 e H2SO4 puro com diferentes valores de pH. O comportamento eletroquímico nas soluções de anodização foi avaliado através de polarização potenciostática. A resistência à corrosão por pites de aços inoxidáveis AISI304L após os tratamentos superficiais foi avaliada por polarização potenciodinâmica a 25 oc em soluções 0,5 M de NaCl. Vários tratamentos resultaram em um aumento do Epir, atingindo valores muito maiores do que aqueles observados para AISI316L não-tratados. Os maiores deslocamentos no potencial de pite foram obtidos em soluções ácidas para potenciais na região passiva. A morfologia, a estrutura e a composição dos óxidos crescidos foram investigadas por RBS, EDS e MET. A incorporação de Nb e Mo nos filmes de óxido para amostras tratadas foi confirmada por RBS. Análises por MET e SAD mostraram que as anodizações em soluções ácidas resultam na formação de filmes espessos de dupla camada, constituídos por espinélios nanocristalinos de F e, Cr e Ni. As propriedades eletrônicas dos filmes passivos formados em eletrólitos ácidos foram estudadas usando EIS. Os resultados obtidos mostraram uma excelente correlação entre a resistência da camada de óxido (Rc) e o aumento no potencial de pite. Por outro lado, não foi verificada uma variação significativa nos valores da capacitância das camadas de óxido dos aços tratados. Os dados experimentais sugerem que o deslocamento no potencial de pite está associado ao enriquecimento de Cr na camada interna de óxido e a uma menor quantidade de defeitos no filme, diminuindo, assim, o número de sítios de nucleação de pites. / The effect of anodic treatments on the corrosion resistance in chloride solutions and on the morphology, structure and composition of oxide layers grown on alloys AISI304 and AISI316L was investigated. For this, AISI304 L and AISI316L stainless steels were polarized at high temperatures in Na2Mo04, NH4H2NbO(C204)3 and pure H2S04 solutions at different pH values. The electrochemical behaviour m the anodizing solutions was evaluated by potentiostatic polarization. The pitting corrosion resistance o f AISI304 L stainless steels after the surface treatments was evaluated by potentiodynamic polarization at 25 °C in 0.5 M NaCl solutions. Severa! treatments resulted in I;,it improvement, attaining values much higher than those observed for the untreated AISI316L. The greatest shift in pitting potential were obtained in acid electrolytes for potentials in the passive range. The morphology, structure and composition of oxide layers were investigated by RBS, EDS and TEM. The incorporation of Nb and Mo in the oxide layers of treated samples was confirmed by RBS. TEM and SAD analysis showed that anodizing in acid solutions results in the formation of double layered thick films constituted of nanocrystalline spinel ofFe, Cr and Ni. The electronic properties of the passive films formed in acid electrolytes was studied using EIS. The obtained results showed a good correlation between the oxide layer resistance (RL) and the pitting potential shift. On the other hand, no significant changes were verified on the oxide films capacitances for treated steels. The experimental data suggest that the pitting potential shift is associated to Crenrichment in the inner oxide layer and decreasing on the deffect densities in the film, thus lowering the amount o f pitting nucleation sites.
224

Estudo do desempenho de aços inoxidáveis modificados para aplicação em meios corrosivos do processamento primário do petróleo

Oikawa, Pedro Masato Venancio January 2009 (has links)
Diante do aumento na demanda por combustíveis fósseis e a descoberta de novos campos de exploração e produção de petróleo cada vez mais remotos e com condições de operação de maior agressividade torna-se evidente a necessidade de desenvolvimento de materiais capazes de resistir a estes novos ambientes. Este trabalho engloba a revisão bibliográfica de três famílias de aços inoxidáveis modificados desenvolvidas nas últimas décadas, os supermartensíticos, os superferríticos e os superausteníticos. A avaliação dos materiais foi realizada quanto à resistência aos mecanismos de deterioração esperados no processamento primário de petróleo com teores elevados de CO2 e presença de H2S, considerando variáveis de processamento comumente utilizadas. Com os resultados encontrados na literatura a luz dos mecanismos de deterioração e considerando as características de processamento, fez-se uma seleção de materiais via matriz de decisão qualitativa para os equipamentos de uma planta de processo de modo a obter a melhor relação de compromisso considerando resistência a corrosão, custo e resistência mecânica. / The increasing demand for fossil fuels and the discovery of new oil fields in remote locations with aggressive operation conditions enlighten the need for development of materials able to resist to this new environments. This work includes a review of three families of modified stainless steels developed in recent decades, the supermartensitic, the superferritic and superaustenitic. The materials were evaluated through the criteria of resistance to the damage mechanisms expected in the primary processing of oil with high levels of CO2 and the presence of H2S, considering variables of the processing plant. With the literature results in the light of the damage mechanisms and considering the characteristics of processing, it was developed a material selection using a qualitative decision matrix for the equipments of a process plant to obtain the best compromise considering resistance to corrosion, cost and strength.
225

Avaliação da resistividade elétrica do concreto como parâmetro para a previsão da iniciação da corrosão induzida por cloretos em estruturas de concreto / Evaluation of the electrical resistivity of concrete as a parameter to calculation of initiation period of corrosion induced by chlorids in concrete structures

Santos, Lourdimine 04 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2006. / Submitted by Fernanda Weschenfelder (nandaweschenfelder@gmail.com) on 2009-11-03T17:59:09Z No. of bitstreams: 1 dissertacao LOURDIMINE SANTOS.pdf: 1793040 bytes, checksum: 598702a943cf62a09e6b1f8402d4db36 (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-05T20:37:55Z (GMT) No. of bitstreams: 1 dissertacao LOURDIMINE SANTOS.pdf: 1793040 bytes, checksum: 598702a943cf62a09e6b1f8402d4db36 (MD5) / Made available in DSpace on 2010-07-05T20:37:55Z (GMT). No. of bitstreams: 1 dissertacao LOURDIMINE SANTOS.pdf: 1793040 bytes, checksum: 598702a943cf62a09e6b1f8402d4db36 (MD5) Previous issue date: 2006-04 / A resistividade elétrica do concreto é um parâmetro bastante sensível às suas características microestruturais, especialmente em relação à conectividade e à distribuição dos diâmetros dos poros. Este parâmetro está relacionado à resistência do concreto à penetração de líquidos ou gases e ao conteúdo de umidade presente nos poros do concreto, fornecendo, assim, indicações a respeito da sua durabilidade. O presente trabalho teve como objetivo avaliar a viabilidade de utilização da resistividade elétrica do concreto como parâmetro para a previsão da iniciação da corrosão em estruturas submetidas à ação dos íons cloreto. Para isso, foram analisadas as relações existentes entre a resistividade elétrica e alguns dos fatores que influenciam a duração do período de iniciação da corrosão das armaduras. Os resultados obtidos foram utilizados para avaliar a viabilidade de utilização do modelo proposto por Andrade (2004) para prever a vida útil de estruturas de concreto armado a partir da sua resistividade elétrica. Foram utilizados concretos com relação água/aglomerante 0,4 e 0,5, com diferentes percentuais de sílica ativa (0% e 10%) em substituição à massa de cimento. Os resultados mostraram a existência de uma correlação entre a resistividade elétrica e o volume de poros com diâmetros entre 0,05 μm e 0,1 μm presente no concreto, uma tendência de redução da capacidade de absorção com o aumento da resistividade elétrica do concreto e uma correlação inversamente proporcional com a difusividade iônica. Além disso, foi observada a existência de uma correlação entre o período de iniciação obtido experimentalmente e a resistividade elétrica do concreto, o que demonstra a viabilidade da utilização deste parâmetro na avaliação da sua vida útil. No entanto, os resultados também indicaram que a aplicação deste parâmetro em estruturas de concreto, principalmente quando forem utilizados concretos com adição de sílica ativa, requer que sejam considerados fatores que interferem no processo construtivo. __________________________________________________________________________________ ABSTRACT / The electrical resistivity of concrete is a very sensitive parameter to its microstructural characteristics, especially in relation to the connectivity and the pore size distribution. This parameter is related to the resistance of the concrete to the penetration of liquids or gases and the moisture content present in the concrete pore network, and therefore, may furnish indicators in relation to its durability. The object of this paper is to evaluate the viability of using the electrical resistivity as a parameter to calculation of the initiation period of corrosion in structures subjected to the action of chloride ions. For this, the relationships existent between electrical resistivity and some of the factors that influence the duration of initiation period of the reinforcement were analyzed. The results obtained were used to evaluate the viability of using the model proposed by Andrade (2004) to predict the service life of reinforced concrete structures by their electrical resistivity. Concrete samples with a water/binder ratio of 0.4 and 0.5 were used, with different rates of silica fume (0% and 10%) as a replacement for cement. The results demonstrated the existence of a correlation between the electrical resistivity and the volume of pores with diameters between 0.05 μm and 0.1 μm present in the concrete; a tendency of lower absorption capacity when there is a higher electrical resistivity in the concrete; and a correlation inversely proportionate to the ionic diffusivity. Furthermore, the existence of a correlation between the initial period obtained experimentally and the electrical resistivity of concrete was observed, which demonstrates the viability of using this parameter in the evaluation of its service life. However, the results also indicated that the application of this parameter in real structures, especially in concrete where silica fume has been used, requires consideration of the factors that influence the construction process.
226

Avaliação experimental do concreto poroso na atenuação do escoamento superficial em parcelas urbanizadas / Experimental evaluation of porous concrete in mitigation of runoff in urbanized portions

Alencar, Paulo Cezar Dias de 27 September 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-01-27T14:09:17Z No. of bitstreams: 1 2013_PauloCezarDiasdeAlencar.pdf: 8624310 bytes, checksum: bcff2118da87a499e32d7b0626c2592d (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-02-12T09:52:45Z (GMT) No. of bitstreams: 1 2013_PauloCezarDiasdeAlencar.pdf: 8624310 bytes, checksum: bcff2118da87a499e32d7b0626c2592d (MD5) / Made available in DSpace on 2014-02-12T09:52:45Z (GMT). No. of bitstreams: 1 2013_PauloCezarDiasdeAlencar.pdf: 8624310 bytes, checksum: bcff2118da87a499e32d7b0626c2592d (MD5) / O desenvolvimento urbano tem provocado mudanças qualitativas e quantitativas sobre o escoamento superficial, sendo necessário, em geral, implementar medidas com o objetivo de compensar a ação humana nas áreas de intervenção e de influência de empreendimentos e assim, restabelecer as condições originais do local ou, pelo menos, mitigar os impactos causados. A presente pesquisa tem por objetivo monitorar a perda da capacidade de infiltração e sua posterior recuperação por meio de lavagem com bomba de alta pressão, bem como analisar aspectos executivos, em uma parcela experimental de concreto. A obra consistiu da construção de um estacionamento revestido com 15cm de concreto poroso, seguido por colchão drenante de 30cm. O experimento foi projetado para permitir o monitoramento da parcela escoada superficialmente e da parcela que infiltra no colchão drenante em três momentos distintos: pavimento novo, pavimento colmatado e depois de recuperado. Quando novo, o concreto poroso se mostrou técnica eficiente de controle do escoamento superficial das águas pluviais, conseguindo drenar 100% de chuvas de 2,35mm/min para o colchão drenante de brita 3 instalado abaixo da placa de concreto. Contudo após sua total colmatação, a limpeza do pavimento não garantiu a total recuperação da permeabilidade inicial do pavimento, tendo sido essa limitada a uma taxa máxima de 21,90L/min na vaga de estacionamento, o que corresponde drenar uma chuva de intensidade de 1,75mm/min. / Urban development has caused qualitative and quantitative changes in the runoff, being necessary, in general, to implement measures in order to compensate the human action in the areas of interventions and influence of businesses and thus restore the original conditions of the site or, at least, mitigate the impacts. This research aims to monitor the loss of infiltration capacity and its subsequent recovery by using high-pressure pump, as well as analyze aspects executives, on a plot of porous concrete. The work consisted of the construction of a parking covered with 15cm of porous concrete, followed by 30cm draining bed. The experiment was designed to allow monitoring of rainfall and infiltrated portion in draining bed in three separate times: new, clogged and recovered pavements. The porous concrete technique has been shown effective to control the runoff of rainwater, achieving 100% drainage of the 2.35 mm/min for the drainage gravel nº3 bed installed below the concrete pavement. However its total fouling, cleaning of the pavement did not guarantee full recovery of the initial permeability of the pavement, these being limited to a maximum rate of 21.90L/min in the parking spot, which corresponds to drain a rain intensity of 1.75 mm/min.
227

Estudo do desempenho de aços inoxidáveis modificados para aplicação em meios corrosivos do processamento primário do petróleo

Oikawa, Pedro Masato Venancio January 2009 (has links)
Diante do aumento na demanda por combustíveis fósseis e a descoberta de novos campos de exploração e produção de petróleo cada vez mais remotos e com condições de operação de maior agressividade torna-se evidente a necessidade de desenvolvimento de materiais capazes de resistir a estes novos ambientes. Este trabalho engloba a revisão bibliográfica de três famílias de aços inoxidáveis modificados desenvolvidas nas últimas décadas, os supermartensíticos, os superferríticos e os superausteníticos. A avaliação dos materiais foi realizada quanto à resistência aos mecanismos de deterioração esperados no processamento primário de petróleo com teores elevados de CO2 e presença de H2S, considerando variáveis de processamento comumente utilizadas. Com os resultados encontrados na literatura a luz dos mecanismos de deterioração e considerando as características de processamento, fez-se uma seleção de materiais via matriz de decisão qualitativa para os equipamentos de uma planta de processo de modo a obter a melhor relação de compromisso considerando resistência a corrosão, custo e resistência mecânica. / The increasing demand for fossil fuels and the discovery of new oil fields in remote locations with aggressive operation conditions enlighten the need for development of materials able to resist to this new environments. This work includes a review of three families of modified stainless steels developed in recent decades, the supermartensitic, the superferritic and superaustenitic. The materials were evaluated through the criteria of resistance to the damage mechanisms expected in the primary processing of oil with high levels of CO2 and the presence of H2S, considering variables of the processing plant. With the literature results in the light of the damage mechanisms and considering the characteristics of processing, it was developed a material selection using a qualitative decision matrix for the equipments of a process plant to obtain the best compromise considering resistance to corrosion, cost and strength.
228

Estudo da capacidade de proteção de alguns tipos de cimentos nacionais, em relação à corrosão de armaduras sob a ação de íons cloreto

Tessari, Ricardo January 2001 (has links)
O concreto normalmente oferece um alto grau de proteção contra a corrosão ao aço, devido à formação de uma fina película protetora na sua superfície, causada pela alta alcalinidade do concreto. Entretanto, essa película pode ser rompida tanto pela diminuição do pH da solução dos poros do concreto (por carbonatação, por exemplo) ou pela penetração de íons agressivos (como cloretos, por exemplo) até a superfície do aço. O presente trabalho tem por objetivo comparar o desempenho de concretos feitos com diferentes tipos de cimento Portland normalizados no Brasil frente à ação de íons cloreto provenientes de fontes externas. O programa experimental foi realizado com cinco diferentes tipos de cimento (CPII-E, CPII-F, CPIV, CPV ARI e CPV ARI-RS), com e sem adições, e cinco relações água/aglomerante (0,30; 0,35; 0,45; 0,60 e 0,80) em ensaios acelerados de despassivação por cloretos, por meio de ciclos de imersão e secagem dos corpos-de-prova em solução contendo 3,5% de cloreto de sódio. O método de Potencial de Eletrodo foi utilizado para monitorar a corrosão ao longo do tempo. Paralelamente foram realizados ensaios de resistência à compressão do concreto aos 28 dias, de perda de massa da armadura e de teor de cloretos livres no cobrimento da armadura. Os resultados obtidos mostraram que a escolha do tipo de cimento tem influência tanto na resistência à compressão simples quanto na resistência à corrosão das armaduras, verificada através dos ensaios de potencial de eletrodo, de perda de massa gravimétrica da armadura e de teor de cloretos livres. No entanto não houve um tipo de cimento que apresentasse os melhores resultados para todos os tipos de ensaio. / Concrete usually provides a high level of protection against steel corrosion, due to the formation of a fine protecting film on its surface, caused by concrete alkalinity. However, this film can be torn both as a result of the decrease in the pH of the solution of the concrete pores (by carbonation, for example) or as a result of the penetration of aggressive ions (such as chlorides, for example) up to the surface of the steel. The present work has the objective of comparing the performance of concrete made with different kinds of Portland cement regulated in Brazil before the action of chloride ions derived from external sources. The experimental program was performed with five different types of cement (CPII-E, CPII-F, CPIV, CPV ARI and CPV ARI-RS), with and without additions, and five water/agglomerative relations (0.30; 0.35; 0.45; 0.60 and 0.80) in acceleration assays of inactivation by chlorides, by means of immersion cycles and drying of proof bodies in a solution contained 3.5% of sodium chloride. The method of Electrode Potential was used to monitor corrosion over time. Concomitantly, resistance tests were performed as to the compression of the concrete at 28 days, from the loss of mass of the armature and content of free chlorides in the armature coating. The results obtained showed that the selection of the kind of cement has an impact both on the simple compression resistance and on the resistance to armature corrosion, verified through tests of electrode potential, of armature gravimetric mass loss and free chloride content. However, there was not a kind of cement presenting the best results for all types of assay.
229

Nanotecnologia aplicada a tratamento superficiais para o aço carbono 1020 como alternativa ao fosfato de zinco

Bossardi, Kelly January 2007 (has links)
O sistema de tratamento do aço tem sido utilizado com o objetivo de aumentar a resistência à corrosão e melhorar a adesão da tinta sobre o substrato. Porém, a fosfatização convencional traz danos ao meio ambiente. Com o intuito de realizar o desenvolvimento sustentável, novos processos de tratamentos têm sido desenvolvidos a fim de substituir o processo de fosfatização, reduzir o impacto ambiental e promover o progresso nos tratamentos. Neste trabalho foi realizada uma avaliação comparativa entre dois tratamentos superficiais para aço de baixo carbono isentos de metais pesados (nanocerâmico e silano) e a fosfatização. Para este estudo foram utilizadas chapas de aço carbono 1020 laminado a frio como substrato. Com o objetivo de verificar a resistência anticorrosiva dos tratamentos sem pintura foram realizados ensaios de exposição à umidade, imersão em água, imersão em soluções aquosas de pH 2 e pH 10 e curvas de polarização anódicas e catódicas e em soluções de NaCl, NaOH e H2SO4. As amostras pintadas com tinta a pó microtexturizada foram submetidas aos ensaios de exposição à névoa salina neutra, dióxido de enxofre e umidade, além dos ensaios mecânicos de aderência, flexibilidade e impacto. Os resultados de resistência mecânica demonstraram um bom desempenho de todos os tratamentos. Quanto à resistência anticorrosiva pode-se verificar, a partir das curvas de polarização anódicas e catódicas,, que os tratamentos testados se comportam de maneira peculiar nos diferentes meios, mostrando uma ligeira superioridade com relação ao fosfato de zinco. Os resultados quanto a resistência à corrosão, para as amostras cujos tratamentos foram conjugados com pintura a pó, mostraram que todos os sistemas obtiveram comportamento semelhante e satisfatório. / The steel treatment system had been using with purpose of increase the corrosion resistance and to improve the paint adhesion on substratum. However, the conventional phosphatetion causes damage the environment. With purpose to permit a sustainable development, new treatment process has been developing in order to replace the phosphatetion process, to minimize the environmental impact and to promote the progress in the treatments. In this work has been carried out an assessment comparative between two different steel treatment area of low carbon, free of heavy metals (nanoceramic and silane) and the phosphatetion. During the study have been used as substratum, steel carbon plate 1020 which was laminated by cold. Having in mind to check the anticorrosive resistance treatments without painting, have been carried test out of exposure to humidity, water immersion besides immersion in water solution of pH 2 and pH 10 and variations of polarization anodic and cathodic besides solutions of NaCI, NaOH and H2SO4. The samples have painted with microtexturizada ink dust have been subjected test of exposition at the neutral saline mist, dioxide of sulfur and humidity, besides mechanical assays of tack, flexibility and impact. The resistance results mechanics had demonstrated a good performance of all the treatments. Regarding anticorrosive resistance, can been verified that from the anodic and cathodic curves of polarization, the tested treatments have had a peculiar performance in each different situations, showing a small superiority considering the phosphating of zinc. However the results of resistance corrosion, for the samples whose treatments had been conjugated with painting the dust, have been shown us that all the systems had gotten similar and satisfactory behavior.
230

Determinação do potencial de agressão dos sais marinhos sobre as argamassas de revestimento na região metropolitana de Salvador / Evaluation of the aggressive potential due to marine salts on mortars used for rendering in the metropolitan region of Salvador, Bahia

Costa, Eduardo Antonio Lima January 2001 (has links)
Atualmente, é crescente a preocupação com relação à vida útil das edificações e com o desempenho dos materiais à agressividade do ambiente. Neste sentido, o estudo do potencial de agressão dos sais marinhos sobre as argamassas de revestimento é crítico. A presença de sais, e a conseqüente pressão de cristalização, são responsáveis por um grande número de manifestações patológicas nos revestimentos de edificações. O controle deste fenômeno se constitui em um fator importante devido, principalmente, aos elevados recursos financeiros necessários para recuperação do patrimônio atingido. O presente trabalho teve por objetivo avaliar o perfil da distribuição espacial dos sais marinhos com relação à distância do mar, através da determinação da taxa de deposição de cloretos, sulfatos e nitratos em sensores de vela úmida posicionados em estações de monitoramento localizadas nos municípios de Salvador, Lauro de Freitas e Camaçari (Região Metropolitana de Salvador). Adicionalmente, foram avaliadas as concentrações de cloretos e sulfatos que efetivamente penetraram, após um processo de deposição e migração, em corpos-de-prova de três tipos de argamassa, com consumos de cimento diferentes. Estes foram moldados com a adição de um argilomineral, localmente denominado de arenoso, visando analisar o comportamento de materiais típicos, pois o arenoso é freqüentemente utilizado em argamassas na região monitorada, mas não foi ainda devidamente estudado. A metodologia empregada permitiu avaliar a eficiência do equipamento de coleta e o desempenho comparativo, quanto à resistência à penetração de sais, dos traços de argamassa estudados. Foram determinados tanto os teores de sais depositados no sensor quanto os migrados para o interior da argamassa por cromatografia iônica. Os resultados foram analisados com relação à distância do mar. É possível concluir que, traços de argamassa com consumos de cimento em torno de 200 kg por metro cubico tem um melhor desempenho com relação a traços mais pobres, de menor consumo de cimento por metro cubico, quanto ao teor de sais efetivamente penetrado, e ainda, que o potencial de distribuição espacial do spray marinho é de maior influencia até 500 metros de distância do mar. A partir desta distância o teor de cloretos cai significativamente e, no caso dos sulfatos, outras fontes de emissões, como veiculares, passam a ser mais importantes como origem desses íons do que o spray marinho. / In recent years, there has been growing interest on the determination of the performance of materials and on the evaluation of the service life of constructions exposed to various environmental actions. In this sense, the determination of the aggressive potential of marine salts on mortars used as external renderings is critical. The presence of salts, and the associated crystallization pressures generated when the water is lost, are frequently responsible for the rapid deterioration of the material, due to tension cracking and spalling. The control and prevention of this deterioration mechanism is important, due to the large monetary resources necessary to repair the affected buildings. The present work had for objective the evaluation of the spatial distribution profile of marine salts in relation to the distance from the sea, by means of the deposition rate of chlorides, sulfates and nitrates in wet candle sensors, located in nine monitoring stations spread on the metropolitan region of Salvador, including sites on the municipalities of Lauro de Freitas and Camaçari. In addition, the determination of salts which effectively penetrated, trough a process of deposition and migration, in three different types of mortars, with varying cement content, was conducted. These mortars were fabricated with the addition of a clayish mineral, locally abundant, denominated “arenoso”. This indigenous material is frequently used as a lime-replacement addition in the region, but has not been properly studied yet. The methodology proposed allowed the evaluation of the efficiency of the monitoring sensors, the measurement of the atmospheric aggressive potential and the determination of the comparative performance, in terms of resistance to salt penetration, of the three mortars tested. The type and amount of salts, both captured in solution and present in the powder samples extracted from the mortars, were determined by means of ionic chromatography. The results were analyzed in regard to the distance from the sea. It is possible to conclude that mortars made with a cement content higher than 200 kg per cubic meter have a better performance in terms of salt penetration compared to mortars with a lower cement content per cubic meter. Also the data collected showed that the aggressive potential of marine salts in the region is significant up to a distance of 500 m from the sea. From this point onwards the amount of chlorides drops sharply and, in the case of sulfates other air emission sources, such as vehicular emissions become more important than the marine spray.

Page generated in 0.0575 seconds