• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 7
  • 4
  • Tagged with
  • 52
  • 21
  • 21
  • 16
  • 16
  • 15
  • 15
  • 15
  • 15
  • 11
  • 11
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Relation dose-volume effets dans les cancers du col utérin traités par curiethérapie adaptative guidée par l'imagerie 3D. / Dose-volume effects relationships in cervix cancer patients treated with image-guided adaptive brachytherapy

Mazeron, Renaud 08 December 2015 (has links)
Objectifs : Etablir des corrélations dose-volume effet entre les paramètres dosimétriques proposés par le GEC-ESTRO et la probabilité de survenue d’événements tels que le contrôle tumoral ou une toxicité radio-induite.Matériel et méthodes : Les données cliniques et dosimétriques de cohortes de patientes traitées à Gustave Roussy et dans différents centres ont été confrontées. Dans un premier temps les paramètres dosimétriques de la curiethérapie 3D ont été comparés à ceux de la curiethérapie classique. Dans un second temps, la topographie des zones les plus exposées des organes à risque, ainsi que l’impact des mouvements de la vessie, du rectum, et du colon sigmoïde sur l’évaluation de la dose délivrée, ont été étudiés. Enfin, des analyses dose-volume effets ont été réalisées.Résultats : Les valeurs des paramètres dosimétriques volumétriques (D2cm3) de la vessie et du rectum se sont révélées faiblement corrélées et significativement supérieures aux doses évaluées aux points de l’ICRU ou à un point vésical alternatif. Les zones les plus exposées de la vessie et du rectum sont apparues situées au-dessus des points de l’ICRU. Les mouvements des organes autour de l’implant pendant la délivrance du traitement sont apparus marginaux pour la vessie et sigmoïde, en dehors de variations individuelles. En revanche, la dose délivrée au rectum étaient en moyenne plus élevée que le dose planifiée. Les analyses dose-volume effets ont montré des corrélations significatives entre D0.1cm3 et D2cm3 et la probabilité de survenue d’une morbidité tardive urinaire ou rectale. De la même manière, des corrélations significatives ont été établies entre la D90 des CTV à haut risque et à risque intermédiaire et la probabilité d’obtention du contrôle local. Divers caractéristiques tumorales (largeur au diagnostic, volume du CTV-HR, stade FIGO), impactent ces relations, de même que l’étalement total du traitement.Conclusion : Des corrélations dose-volume effets ont été établies entre les paramètres dosimétriques modernes et la probabilité d’obtenir le contrôle local ou d’entraîner une morbidité tardive. En ce qui concerne le contrôle tumoral, les objectifs de prescription doivent être personnalisés en fonction de critères carcinologiques. Pour les organes à risque, de contraintes de dose basées sur l’expérience de la curiethérapie 3D peuvent être établies, mais doivent être affinées dans de futures études en fonction de cofacteurs tels que les comorbidités. Les points gardent un intérêt en recherche clinique, pour l’étude de la morbidité vésicale ou vaginale.Ce travail a l'objet de 6 publications dans des revues internationales à comité de lecture. La septième est présentée sous forme de manuscrit. / Objectives: To establish dose-volume effects correlations between volumetric dosimetric parameters proposed by the GEC-ESTRO and the probability of occurrence of events such as tumor control or radiation-induced toxicity.Methods: Clinical and dosimetric data of patients treated at Gustave Roussy and in different centers have been reviewed. At first step, dosimetric parameters of image-guided brachytherapy were compared with those of conventional brachytherapy. Secondly, the topography of the most exposed areas of the organs at risk, and the impact of the movements of the bladder, rectum, and sigmoid colon on the assessment of the delivered dose, were studied. Finally, analyzes dose-volume effects were performed.Results: The values of volumetric dosimetric parameters (D2cm3) of the bladder and rectum appeared weakly correlated and significantly higher than the doses evaluated at ICRU points of bladder and rectum , an even in an alternative bladder point. The most exposed areas of the bladder and rectum appeared located above the points of the ICRU. The movements of the organs around the implant during the delivery of the treatment appeared marginal for the bladder and sigmoid, apart from individual variations. However, the mean delivered dose to the rectum was higher than the planned dose. Dose-volume effects correlations showed significant correlations between D0.1cm3 and D2cm3 and the probability of occurrence of urinary or rectal late morbidity. Similarly, significant correlations have been established between the D90 of the high risk, intermediate risk-CTV and the probability of achieving local control. Various tumor characteristics (width, HR-CTV volume, FIGO stage) impact these relationships, as well as the treatment time.Conclusion: Dose-volume effects correlations have been established between modern dosimetric parameters and the probability of achieving local control or cause late morbidity. Regarding tumor control, prescription aims must be customized according to oncologic criteria. For organs at risk, new dose constraints based on 3D brachytherapy experience can be established but should be refined in future studies based on cofactors such as comorbidities. The points retain an interest in clinical research for the study of bladder or vaginal morbidity.
52

Caractérisation des spectres énergétiques d'une nouvelle source de curiethérapie par émetteurs alpha diffusant à l'aide d'un compteur à scintillation liquide

Farokhimoghadam, Farideh 03 1900 (has links)
Les cellules cancéreuses se multiplient de manière incontrôlée, se propagent dans le corps et constituent une menace significative à la santé publique, mettant en évidence la nécessité de traitements universels. Parmi les modalités thérapeutiques complémentaires, la radiothérapie est une des plus couramment utilisée pour éliminer ces cellules. L’introduction récente de la Radiothérapie par Émetteurs Alpha Diffusants (Alpha DaRT), une thérapie innovante contre le cancer, utilise des sources radioactives contenant des atomes de Ra-224 pour améliorer l'efficacité du traitement en exploitant les propriétés radiobiologiques des particules alpha. L'objectif de cette étude est de caractériser le spectre énergétique d’une source Alpha DaRT en distinguant les particules alpha et bêta, et d'évaluer les activités du Ra-224 et de ses descendants à l’aide d’un compteur à scintillation liquide moderne. Grâce à l'utilisation du compteur à scintillation liquide Hidex 600 SLe, équipé de trois PMT, et de la séparation alpha/bêta 2D/3D, il est possible de déterminer les activités absolues des radionucléides. La séparation alpha/bêta 2D/3D surmonte les limitations des études précédentes et offre une représentation visuelle unique des spectres, améliorant ainsi la caractérisation des sources Alpha DaRT. Le suivi sur plusieurs mois d’une source Alpha DaRT, avec la décroissance progressive de son activité, et la mesure par scintillation liquide de son facteur d’efficacité en excluant les traces de contamination au Th-228, supportent la faisabilité d’utiliser cette méthode de mesure sur une longue période. Pour ce faire, le compte des particules alpha et bêta a été séparés par le compteur et classifié en fonction de l’énergie émise des particules. Un programme maison en Python a été développé pour extraire les activités de chaque fille dans la chaîne de désintégration du Ra-224. Un résultat intéressant est qu’en raison de la décroissance rapide (demi-vie de 0,3 μs) du Po-212 (une descendante du Ra-224), une partie de l'activité alpha totale n’est pas mesurée par le compteur. Ce phénomène doit être pris en compte lors de l'évaluation des efficacités de la scintillation liquide pour les mesures quantitatives des sources Alpha DaRT. Les résultats ont ensuite été comparés à aux valeurs attendues de la littérature et des calculs numériques. / Cancer cells multiply uncontrollably, spread throughout the body, and pose a significant public health threat, requiring the need for universal treatments. Among the complementary therapeutic modalities, radiotherapy is one of the most commonly used to eliminate these cells. The recent introduction of Alpha DaRT (Diffusing Alpha-emitters Radiation Therapy), an innovative cancer therapy, involves the use of radioactive sources containing Ra-224 atoms to enhance treatment efficacy by exploiting the radiobiological properties of alpha particles. The aim of this study is to characterize an Alpha DaRT source by distinguishing alpha and beta particles, and to evaluate the activities of Ra-224 and its descendants using a modern liquid scintillation counter. With the use of the Hidex 600 SLe liquid scintillation counter, equipped with three PMTs, and the 2D/3D alpha/beta separation method, it is possible to determine the absolute activities of the radionuclides. The 2D/3D alpha/beta separation method overcomes the limitations of previous studies and provides a unique visual representation of spectra, thereby improving the characterization of Alpha DaRT sources. Monitoring an Alpha DaRT source over several months, with its progressively decaying activity, and measuring its efficiency excluding traces of Th-228 contamination, confirm the feasibility of using this method of measurement over a long period. Counts from alpha and beta particles were separated by the counter and binned according to their emitted energies. An in-house Python program was developed to extract the activities of each daughter in the Ra-224 decay chain. An interesting finding is due to the fast (0.3 μs half-life) decay of Po-212 (Ra-224 daughter), part of the alpha activity is missed by the counter. This phenomenon should be considered when assessing the efficiency of liquid scintillation for quantitative measurements of Alpha DaRT sources. These results were then compared to expected values from literature and numerical calculations.

Page generated in 0.0382 seconds