Impact de la curiethérapie à haut débit (HDR) et de la suppression androgénique sur la réponse cellulaire des cancers localisés de la prostate

Chebra, Imen 03 August 2022 (has links)
Le cancer de la prostate (CaP) est le cancer le plus diagnostiqué chez les hommes au Canada. La curiethérapie HDR combinée à la radiothérapie externe (EBRT) et l'hormonothérapie (ADT) constitue une excellente approche thérapeutique pour traiter le CaP à risque intermédiaire et élevé. Le traitement par irradiation ciblée (HDR-BT ou EBRT) livre une dose suffisamment élevée de radiations vers les cellules cancéreuses pour les éradiquer en entraînant des cassures dans l'ADN. Ces dommages mènent les cellules à activer les voies de réparation d'ADN. Cependant, lorsque les dommages sont excessifs et irréparables, les cellules arrêtent le processus de réparation. Elles se dirigent vers la mort cellulaire en activant les voies apoptotiques. D'autre part, la suppression androgénique (ADT) peut activer l'apoptose ou la sénescence cellulaire dépendamment de durée de traitement. Il y a donc plusieurs voies de signalisation qui peuvent être possiblement activées à la suite du traitement HDR-BT/ EBRT avec ou sans hormonothérapie (ADT) Le but de ce projet est de comprendre la réponse cellulaire au traitement par HDR/ EBRT, ainsi qu'illustrer l'impact de l'ajout l'ADT sur cette réponse. Notre approche expérimentale consiste à évaluer l'expression et l'activation des marqueurs liés aux dommages et de réparation d'ADN γ-H2AX, DNA-PKcs et la recombinase Rad51, et mesurer aussi l'expression de Ki67 et p53, ainsi que les marqueurs apoptotiques Bax et PUMA, et le marqueur de senescence p16[exposant INK4] dans les biopsies de 22 patients avant, et après traitement avec HDR/ EBRT (avec ou sans ADT) en utilisant les techniques d'immunohistochimie (IHC) et immunofluorescence (IF). Nos résultats montrent que le traitement par radiations (HDR-BT/ EBRT) a permis d'activer la voie de réparation c-NHEJ. Cependant, cette voie est bloquée probablement à cause de l'activation de l'apoptose. En outre, il a été constaté que l'hormonothérapie additionnelle a induit la sénescence cellulaire après avoir inhibé la voie de réparation c-NHEJ.
12

Combinaison de technologie de suivi électromagnétique et imagerie médicale 3D pour la reconstruction des implants utilisés en curiethérapie à haut débit de dose

Gomez Sarmiento, Isaac Neri 08 February 2024 (has links)
Titre de l'écran-titre (visionné le 1er février 2024) / La curiethérapie à haut débit de dose permet de faire des traitements localisés du cancer en utilisant une source radioactive placée temporairement à proximité ou dans la tumeur du patient à l'aide des implants. La source est acheminée par un projecteur de source. Le succès de ce type de traitement est en partie lié à la localisation exacte de ces implants grâce à l'imagerie médicale tridimensionnelle (3D) ; leurs coordonnées 3D sont utilisées pour optimiser la dose administrée à la tumeur tout en épargnant les tissus sains environnants. Présentement en clinique, les coordonnées sont obtenues par reconstruction manuelle par des physicien(ne)s médical(e)s, mais il peut y avoir des erreurs d'identification lorsque les cathéters se chevauchent, l'épaisseur de coupe des images est trop grande ou le contraste n'est pas suffisant. Le Centre intégré de cancérologie du CHU de Québec-Université Laval, possède l'un des trois prototypes de recherche de projecteur de source au monde qui intègre un capteur de suivi électromagnétique (EM). Celui-ci permet la reconstruction automatique de la géométrie 3D des implants, ainsi surmontant les limitations des reconstructions basées sur les images, tel que le contraste et la résolution spatiale. L'un des défis de la technologie EM est qu'elle ne partage pas intrinsèquement le même référentiel que l'imagerie médicale du patient. Ce mémoire compare des méthodologies de reconstruction des implants avec le capteur EM (statique et en mouvement continu) dans des environnements cliniquement pertinents, ainsi que des méthodes pour recaler ces mesures dans le référentiel d'un ensemble d'images de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM). Un nouveau fantôme a été utilisé pour faire des expériences d'assurance qualité et valider une méthode de recalage novatrice basée sur la géométrie d'un applicateur gynécologique. La méthodologie d'acquisition EM en mouvement continu et la méthode de recalage avec l'applicateur ont permis d'erreurs de recalage moyennes (EM vers TDM) avec une exactitude cliniquement acceptable (< 2 mm) et un temps de reconstruction de 6 minutes dans les salles de curiethérapie avec TDM et IRM. Puisque l'applicateur est aussi visible dans l'IRM, cette méthodologie pourrait potentiellement être étendue pour la planification de curiethérapie gynécologique interstitielle utilisant seulement l'IRM, où les cathéters interstitiels sont difficiles à visualiser. Bien qu'il reste encore à faire plusieurs mesures de validation, cette approche pourrait éviter le déplacement des patientes pour faire un examen d'imagerie TDM afin de reconstruire les cathéters, gagnant ainsi du temps et évitant le rayonnement supplémentaire du TDM.
13

Bioimpression d'un modèle en hydrogel épousant la forme d'un œil pour des applications en curiethérapie

Lemay, Sophie 30 May 2022 (has links)
Le mélanome uvéal représente la majorité des cancers primaires intraoculaires chez l'adulte et 90% des cas sont situés dans la choroïde. Souvent, le mélanome uvéal est traité par curiethérapie ou radiothérapie interne. Dans ce traitement, une plaque épisclérale contenant des sources radioactives est placée par chirurgie sur la sclère du patient afin d'y déposer une dose énergétique permettant de faire diminuer le volume tumoral. Le mélanome uvéal se caractérise par des différences dans les niveaux de radiosensibilité des cellules présentes dans la tumeur. Or, ce facteur n'est pas considéré dans les modèles dosimétriques (« fantômes ») actuellement employés par les physiciens médicaux pour la planification du traitement de curiethérapie. Ce projet de maîtrise consiste à concevoir un fantôme dosimétrique à base d'hydrogel, produit par bioimpression, reprenant certaines caractéristiques géométriques de l'œil, et contenant des cellules présentant différents niveaux de radiosensibilité. Pour ce faire, un hydrogel à d'alginate (fonction mécanique), de gomme de xanthane (fonction imprimabilité) et de collagène de type I (fonction cellulaire) a été optimisé en fonction de son imprimabilité en appareil de bioimpression. Une technique a été développée, permettant l'impression d'un dôme d'hydrogel reprenant la géométrie d'une sclère humaine. La viabilité de cellules du mélanome uvéal dans l'hydrogel a été quantifiée pour trois (3) lignées (Mel270, Mμ2, 92.1) possédant des niveaux de radiosensibilité différents, ainsi que pour une lignée saine (fibroblastes stromaux choroïdiens). Ces tests, comparant les valeurs de viabilité avec et sans procédure de bioimpression, ont permis de déterminer la fenêtre optimale d'utilisation des différentes lignées cellulaires pour des expériences de dosimétrie futures. Le modèle de fantôme ainsi développé permettra d'imprimer des formes tumorales contenant des cellules de différents niveaux de radiosensibilité, afin de mieux mesurer le dépôt de la dose par les plaques épisclérales sur les cellules du mélanome uvéal et de la sclère pendant le traitement de curiethérapie. / Uveal melanoma is the most frequent type of intraocular primary cancer and 90% of these tumours are located in the choroid. Uveal melanoma is usually treated by brachytherapy or internal radiotherapy. In this treatment, an episcleral plaque containing radioactive sources is surgically placed onto the patient's sclera to deposit an energetic dose that will reduce the tumor volume. Uveal melanoma is known to be a type of cancer that shows a wide range of radiosensitivity among the different cells that compose the tumour. However, radiosensitivity data are not taken into account in the current dosimetry models ("phantoms") used to prepare the treatment by the medical physicists. This master's project aims at developing, by 3D printing, an eye-shaped cell-laden hydrogel dosimetry phantom that could be used for studying the effect of radiotherapeutic treatments on different cell types that are associated with different radiosensitivity levels. A hydrogel of alginate (mechanical function), collagen type I (cellular function) and xanthan gum (printability function) was optimized for its printability. A technique was developed to print a dome-shaped hydrogel having the geometry of the human sclera. The cell viability of uveal melanoma in the hydrogel was quantified for 3 cell lines (Mel270, Mμ2, 92.1) having different levels of radiosensitivity, as well as for a healthy cell line (choroidal stromal fibroblasts). These tests that compare the cell viability with and without printing procedures indicated the optimal window for the use of the different cell lines in future dosimetry experiments. The dosimetry phantoms model thus developed will allow the printing of tumor shape containing cells with different radiosensitivity level to better measure the deposition of the dose by the episcleral plaque son uveal melanoma cells and the sclera during the treatment of brachytherapy.
14

Suivi électromagnétique en curiethérapie à haut débit de dose : performance et rôle de la technologie

Tho, Daline 05 March 2023 (has links)
La curiethérapie à haut débit de dose est un traitement anti-cancer utilisé pour différents sites tels les cancers gynécologiques, la prostate, le sein, la tête et le cou. La technique consiste à déposer de la dose de radiation près ou à l'intérieur de la tumeur. Différentes étapes composent ce traitement et des erreurs peuvent s'introduire dans chacune d'entres elles. Par le passé, plusieurs études ont utilisé la dosimétrie in vivo pour détecter et éliminer certaines erreurs de la chaîne. Cette pratique n'est pas uniformisée, puisqu'aucune solution commerciale n'existe sur le marché actuellement. En plus de la dosimétrie, des systèmes de suivi élecromagnétique ont aussi prouvé qu'ils pouvaient être utilisés pour la détection d'erreurs avant le traitement. Ce projet de doctorat explore des erreurs possibles dans la chaîne de traitement et propose le suivi électromagnétique comme étant une solution pour éviter celles-ci. Dans cette thèse, la fabrication d'un dosimètre et l'utilisation du suivi électromagnétique dans le cadre de la curiethérapie à haut débit de dose y sont traitées. Tout d'abord, une étude rétrospective a été complétée pour faire ressortir les performances requises d'un dosimètre in vivo utilisé pendant des traitements du cancer de la prostate. Les positions d'arrêts et les temps d'arrêts de tous les patients ont été extraits des fichiers de chaque traitement. Un dosimètre virtuel a été positionné dans un des cathéters de traitement pour chacun des patients. Une comparaison des temps d'arrêts et des positions d'arrêt sa été complétée pour l'identification des cathéters. Il a été démontré qu'une précision de 1 mm sur la distance source-dosimètre serait idéale. Pour la cohorte de patient utilisée, les temps d'arrêts sont de meilleurs discriminants que les positions d'arrêts. Une précision temporelle de 0,1 s serait idéale. Par la suite, une sélection du capteur électromagnétique pour la construction d'un dosimètre intégrant le suivi électromagnétique de sa position a été réalisée. La dépendance angulaire et la distance capteur-scintillateur ont aussi été étudiées. Parmi les capteurs disponibles, celui possédant le plus petit effet sur la réponse du scintillateur a été utilisé. La reconstruction d'un prototype d'un applicateur blindé pour les cancers gynécologiques a été faite à l'aide du suivi électromagnétique (EM). L'erreur moyenne du capteur sélectionné pour cette étude était de 0,17 mm lorsqu'il se trouvait à 250 mm du générateur de champ. Aucune différence significative sur la mesure n'a été observée à proximité du blindage de cet applicateur. Le suivi EM a aussi été testé lorsqu'il était intégré dans un câble de vérification d'un projecteur de source (Flexitron, Elekta Brachytherapy, Veenendaal, Pays-Bas). Les coordonnées de reconstructions ont été prises lors de la rétraction du câble de vérification. Une comparaison des reconstructions avec différentes vitesses de rétraction du câble a été faite. Les décalages de 5 mm ont tous été identifiés avec une vitesse de reconstruction de 10 cm/s. Néanmoins, il faut une vitesse maximale de 2,5 cm/s pour détecter les décalages de 1 mm. Deux dosimètres avec suivi EM ont été construits, soit un avec une fibre scintillante de plastique(BCF-60) et l'autre avec un scintillateur inorganique (ZnSe:O). Les dosimètres construits ont été calibrés. Les mesures de dose ont été faites en respectant les conditions de diffusion complète et ont été comparées avec le formalisme du TG-43. Par rapport à ce dernier, le dosimètre organique avait une différence de 1,7± 0,2 % alors que l'inorganique possédait une différence de 1,5± 0,7 %pour des distances source-dosimètre allant de 8 mm à 60 mm. Une étude de détection d'erreur a été accomplie. Un gain maximal de 24,0 % est observé pour les déplacements latéraux de 0,5 mm pour le dosimètre inorganique lorsque le suivi EM est utilisé, tandis qu'un gain maximal pour les déplacements longitudinaux (0,5 mm) de 17,4 % a été montré pour ce même scintillateur. Les différents résultats de ce projet quantifient les gains ainsi que les perpectives que l'ajout du suivi EM apportent à la curiethérapie HDR et justifient son introduction dans ce domaine. / High-dose-rate (HDR) brachytherapy is a cancer treatment used for various sites such as gynecological, prostate, breast, head and neck cancers. The technique consists in delivering a dose of radiation by having one or multiple sources in close proximity or with in a tumor. This is a multi-step process and errors can happen at any step during its execution. Several studies have used in vivo dosimetry to detect and avoid possible errors. This practice is not standardized, as no commercial solution currently exists on the market. In addition to dosimetry, electromagnetic (EM) tracking systems have also proven to be useful for the detection of some pre-treatment errors. This thesis explores errors that can occur during the treatment process and suggests a solution based on electromagnetic tracking. The construction of a dosimeter and the use of an EM tracking will be studied in the context of high-dose-rate (HDR) brachytherapy. First, a retrospective study was completed to highlight the required performance of an in vivo dosimeter during prostate cancer treatments. Dwell positions and dwell times for all patients were extracted from each treatment file. A virtual dosimeter was positioned in one of the treatment catheters for each patient. A comparison of each dwell times and dwell positions was completed for the identification of catheters. It has been shown that an accuracy of 1 mm would be ideal on the source-dosimeter distance. For the studied patient cohort, dwell times are better discriminators than dwell positions. This study showed that it is important to avoid placing the dosimeter near the center of the implant. Then, a selection of components for the construction of the dosimeter was performed. Among the available sensors, the one with the smallest impact on the scintillator response was chosen for the work quantifying the gain of EM tracking. The angular dependence and the sensor-scintillator distance were also studied. The reconstruction of a shielded applicator prototype for gynecological cancer was made using EM tracking. An average error of the selected sensor for this study was 0.17 mm when it was 250 mm from the field generator. EM tracking was also tested when integrated into the check cable of an after loader (Flexitron, Elekta Brachytherapy, Veenendaal, Netherlands). The reconstruction coordinates were taken during retraction of the check cable. A comparison of the reconstructions for different cable speeds was made. From this study, the speed for a linear path reconstruction is recommended at 5 cm/s. The 5-mm shifts were all identified with a reconstruction speed of 10 cm/s. Nevertheless, a maximum speed of 2.5 cm/s was needed to detect 1-mm shifts. Two dosimeters were constructed, one with a plastic scintillating fiber (BCF-60) and one with an inorganic scintillator(ZnSe:O). All dose measurements were made in full scatter conditions and were compared with the TG-43 formalism. Compared to the latter, the organic dosimeter had a difference of 1.7± 0.2 % while the inorganic had a difference of 1.5± 0.7 % over an interval of 8 mm to 60 mm from the source. An error detection study was performed and a comparison was made to determine the gain provided by the EM tracking. A maximum gain of 24.0 % was observed with a lateral displacement of 0.5 mm for the inorganic dosimeter. For longitudinal displacements (0.5 mm), a maximum gain of 17.4 % was shown for this same scintillator. The different results obtained in this project will quantify the performance for the construction of an in vivo dosimeter for HDR brachytherapy. The gains from the addition of EM monitoring to HDR brachytherapy will justify its use in this field.
15

Amélioration du calcul de dose TG-43 en curiethérapie à bas débit par un algorithme de dose primaire et diffusée sur processeur graphique

Bourque, Alexandre 19 April 2018 (has links)
Les calculs de dose en curiethérapie à bas débit reposent depuis 1995 sur un formalisme qui considère le milieu irradié comme étant homogène et constitué d’eau afin de mieux accommoder les temps de calcul clinique. Ce travail présente une amélioration de ce formalisme dosimétrique issu du protocole TG-43 de l’AAPM (American Association of Physicists in Medicine), utilisé actuellement dans les systèmes de planification de traitement (SPT) clinique. Avec l’ajout d’un tracé radiologique pour tenir compte des hétérogénéités et en séparant la dose primaire de la dose diffusée, il est possible de raffiner les calculs dosimétriques. Or, cette modification au calcul le rendant plus complexe était coûteuse en temps d’exécution jusqu’à très récemment. Elle se voit matérialisée dans ce travail avec l’arrivée récente de la technologie GPGPU, les calculs scientifiques sur périphériques graphiques. En exploitant le parallélisme des calculs de dose en curiethérapie à bas débit pour les implants permanents, l’algorithme baptisé TG-43-RT pour TG-43 avec tracé de rayons (Ray-Tracing en anglais) permet d’obtenir des facteurs d’accélération de l’ordre de 103 par rapport au CPU. Seulement 0.5 s par source est requis dans une géométrie de 1003 voxels, et les dosimétries d’anatomies hétérogènes sont sensiblement améliorées. Le TG-43-RT corrige les dépôts de dose en aval des hétérogénéités et réduit les effets indésirables de l’atténuation inter-sources. Des écarts de dose de plus de 80% au-delà d’une calcification avaient de quoi influencer les HDV, or, le TG-43-RT ramène ces déviations en-deçà de l’incertitude de 8.7% (2σ) concédée par les SPT, tel qu’établi dans le TG-138. Les simulations Monte Carlo ont été employées pour servir de référence absolue à la méthode développée et quantifier les améliorations dosimétriques relatives à l’actuel calcul de dose. L’algorithme a été testé d’un point de vue clinique dans un fantôme de prostate avec des sources d’125I et dans un fantôme de sein avec des sources de 103Pd pour unifier les corrections apportées. / Brachytherapy dose calculations have been relying since 1995 on a formalism that considers the whole geometry as a homogeneous water tank. This gives the opportunity to compute dose distributions within a reasonable clinical timeframe, but with considerable approximations that can influence or even change the treatment. This work presents an upgraded version of this formalism derived from the TG-43 protocol (AAPM), currently used in actual treatment planning systems. The new algorithm includes a primary and scatter dose separation using ray-tracing operation to account for heterogeneities through the medium. These modifications to the dose calculation are very power consuming and too long for the clinical needs when executed on modern CPUs. With the GPGPU technology, a GPU-driven algorithm allows a complex handling of the anatomic heterogeneities in the dose calculation and keeps execution times below 0.5 s/seed. The algorithm was named TG-43-RT for TG-43 with Ray-Tracing and accelerations factors of three order of magnitude were obtained over a regular CPU implementation. The TG-43-RT algorithm adequatly corrects dose deposition along heterogeneities and it reduces interseed attenuation effects. Dose is scored in the medium instead of water, which also applies a severe correction for high heterogeneous medium like the breast. Deviations of more than 80% in dose deposition were obtained over calcification inside the prostate when compared to Monte Carlo simulations. This kind of deviation influences DVH shape. However, the TG-43-RT was keeping those deviations within the 8.7% uncertainty range (2σ) associated with a regular TG-43 evaluation as stated in the TG-138. Monte Carlo simulations were used as a gold standard to get an absolute dose calculation reference. The algorithm was also tested in a prostate phantom with 125I seeds and in a breast phantom with 103Pd seeds to mimic real anatomic geometries and unify the applied corrections.
16

Développement d'actionneurs pneumatiques compliants pour la robotique binaire appliquée aux interventions intra-IRM pour la prostate

Miron, Geneviève January 2012 (has links)
En raison de l'augmentation continuelle des coûts en santé, il est profitable de détecter et traiter tôt les cancers afin de diminuer les coûts de traitement à long terme. La problématique s'applique particulièrement au cancer de la prostate, qui constitue 25 % des nouveaux cas de cancer chaque année. Afin de pouvoir détecter avec un niveau de confiance élevé les petites tumeurs durant les premiers stades de développement, l'Imagerie par résonance magnétique (IRM) peut être utilisée en raison de la qualité de son imagerie des tissus mous. Cependant, les IRM offrent un accès limité au patient (diamètre < 70 cm), limitant ainsi les possibilités d'interventions intra-IRM.En combinant la précision et la polyvalence d'un système robotique et la précision de l'imagerie par IRM, il serait donc possible de pouvoir détecter et traiter tôt les petites tumeurs pour augmenter les chances de survie des patients, et ainsi, réduire une partie des coûts en santé. Les interventions visées incluent la biopsie (prélèvement), la cryothérapie (brûlure par le froid), la curiethérapie (dépôt de pastilles émettrices de radiations) et l'ablation thermique par laser. La compatibilité IRM (qui exige le fonctionnement sous un champ magnétique de plus de 7 teslas) et l'espace confiné sont les deux principaux défis de la robotique en IRM, et nécessitent l'implantation de nouveaux types d'actionneurs. Le mémoire présente la conception et la fabrication de muscles pneumatiques de polymère et leur application à un manipulateur robotisé pour le cancer de la prostate. L'intégration des muscles pneumatiques dans des structures de polymère permet de simplifier leur fabrication, en plus d'assurer plus de précision en diminuant les erreurs liées à la fabrication. Une méthode de conception est développée, utilisant un modèle de manipulateur et quatre modèles de muscles. La modélisation des muscles débute par un modèle géométrique et est suivie d'un raffinement géométrique par éléments finis. Les éléments finis servent également à valider l'hypothèse de déformation uniaxiale du muscle qui sert de prémisse au troisième modèle, un modèle 1-D analytique qui prédit les performances du muscle. Enfin, le muscle est modélisé en se basant sur une caractérisation expérimentale. Les muscles pneumatiques, intégrés dans une architecture parallèle, permettent d'améliorer la précision des interventions intra-IRM tout en maintenant un rapport efficacité-coût élevé. Les performances des muscles pneumatiques et du manipulateur sont validées expérimentalement et permettent d'atteindre les requis cliniques de l'application de détection et traitement du cancer de la prostate. Les expériences en laboratoire et en IRM ont en effet permis de démontrer une erreur en boucle fermée inférieure à 0.5 mm, une rigidité adéquate de 0.32 N/mm et une absence d'impact du manipulateur sur la qualité des images d'IRM. Enfin, les performances des muscles pneumatiques intégrés ouvrent la porte à de nouvelles applications et à un changement de paradigme pour la conception de robots binaires précis à faible coût.
17

Utilisation de la tomodensitométrie à deux énergies pour le calcul de dose en curiethérapie à bas débit

Côté, Nicolas 08 1900 (has links)
Dans la pratique actuelle de la curiethérapie à bas débit, l'évaluation de la dose dans la prostate est régie par le protocole défini dans le groupe de travail 43 (TG-43) de l'American Association of Physicists in Medicine. Ce groupe de travail suppose un patient homogène à base d'eau de même densité et néglige les changements dans l'atténuation des photons par les sources de curiethérapie. En considérant ces simplifications, les calculs de dose se font facilement à l'aide d'une équation, indiquée dans le protocole. Bien que ce groupe de travail ait contribué à l'uniformisation des traitements en curiethérapie entre les hôpitaux, il ne décrit pas adéquatement la distribution réelle de la dose dans le patient. La publication actuelle du TG-186 donne des recommandations pour étudier des distributions de dose plus réalistes. Le but de ce mémoire est d'appliquer ces recommandations à partir du TG-186 pour obtenir une description plus réaliste de la dose dans la prostate. Pour ce faire, deux ensembles d'images du patient sont acquis simultanément avec un tomodensitomètre à double énergie (DECT). Les artéfacts métalliques présents dans ces images, causés par les sources d’iode, sont corrigés à l'aide d’un algorithme de réduction d'artefacts métalliques pour DECT qui a été développé dans ce travail. Ensuite, une étude Monte Carlo peut être effectuée correctement lorsque l'image est segmentée selon les différents tissus humains. Cette segmentation est effectuée en évaluant le numéro atomique effectif et la densité électronique de chaque voxel, par étalonnage stoechiométrique propre au DECT, et en y associant le tissu ayant des paramètres physiques similaires. Les résultats montrent des différences dans la distribution de la dose lorsqu'on compare la dose du protocole TG-43 avec celle retrouvée avec les recommandations du TG-186. / In current low dose rate brachytherapy practice, dose evaluation within the prostate is govern by the protocol defined by the task group 43 (TG-43) of the American Association of Physicist in Medicine. This task group assumes a homogeneous water based patient with invariable density. They also disregard the changes in photon attenuation through neighbouring brachytherapy sources. With the introduction of these simplifications, dose calculations are easily solved using an equation proposed in this protocol. Although this task group helped create a uniform practice of brachytherapy treatments between hospitals, it does not properly described the actual dose distribution within the patient. The current publication of TG-186 gives recommendations to study these dose distribution more realistically. The purpose of this Master's thesis is to apply these recommendations from TG-186 to obtain a more realistic description of the dose. In order to proceed, two sets of patient images are acquired with a dual energy computed tomography (DECT). These images are corrected for metallic artifacts, which are highly present in the scanned images, using DECT metallic artifact reduction algortithm, developped in this work. Afterwords, a Monte Carlo study can be performed by properly identifying the environment with human tissues. This segmentation is performed by evaluating the effective atomic number and electronic density of each voxel using a DECT stoichiometric calibration, and allocating the tissue having the closest resemblance to these physical parameters. The results show clear differences in dose distribution when comparing TG-43 protocole with TG-186 recommendations.
18

Étude de la réponse dosimétrique du Nitrure de Gallium (GaN) : modélisation, simulation et caractérisation pour la radiothérapie / Study of the dosimetric response of Gallium Nitride (GaN) : modeling, simulation and characterization on radiotherapy

Wang, Ruoxi 27 May 2015 (has links)
Ce travail de thèse a pour but d'améliorer la précision de mesure de la dosimétrie basée sur le transducteur en Nitrure de Gallium (GaN) et de développer son application en radiothérapie. L'étude comprend des phases de modélisation, de simulation et de caractérisation de cette réponse pour la radiothérapie externe et la curiethérapie. En modélisation, nous avons proposé deux approches pour modéliser la réponse du transducteur GaN en radiothérapie externe. Dans la première approche, un modèle a été construit à partir de données expérimentales et en séparant les composantes primaires et diffusées du faisceau. Pour la deuxième approche, nous avons adapté un modèle initialement proposé pour les diodes silicium pour l'adapter au transducteur radioluminescent GaN. Nous avons également proposé un concept original de dosimétrie bi-média qui permet à partir des réponses mesurées des deux média de remonter à la dose dans les tissus, sans connaissance à priori des conditions d'irradiation. Ce concept a été démontré par des simulations Monte Carlo. Par ailleurs GaN pour la curiethérapie à Haut Débit de Dose, la réponse du transducteur GaN sous irradiation des sources d'iridium 192 et de cobalt 60 a été évaluée par simulation Monte Carlo et confirmée par des mesures. Des études de caractérisation des propriétés du transducteur radioluminescent GaN ont été réalisées avec ces sources. Un prototype de fantôme instrumenté avec des sondes GaN a été développé pour le contrôle qualité en curiethérapie HDR. Il permet de vérifier en temps réel les paramètres physiques du traitement (position de la source, le temps d'exposition, activité de la source) / The work in this thesis has the objective to increase the measurement precision of the dosimetry based on the Gallium Nitride (GaN) transducer and develop its applications on radiotherapy. The study includes the aspects of modeling, simulation and characterization of this response in external radiotherapy and brachytherapy. In modeling, we have proposed two approaches to model the GaN transducer’s response in external radiotherapy. For the first approach, a model has been built based on experimental data, while separating the primary and scattering component of the beam. For the second approach, we have adopted a response model initially developed for the silicon diodes for the GaN radioluminescent transducer. We have also proposed an original concept of bi-media dosimetry which evaluates the dose in tissue according to different responses from two media without prior information on the conditions of irradiation. This concept has been shown by Monte Carlo simulation. Moreover, for High Dose Rate brachytherapy, the response of GaN transducer irradiated by iridium 192 and cobalt 60 sources has been evaluated by Monte Carlo simulation and confirmed by the measurements. Studies on the property characterization of GaN radioluminescent transducer has been carried out with these sources as well. An instrumented phantom prototype with GaN probe has been developed for the HDR brachytherapy quality control. It allows a real-time verification of the physics parameters of a treatment (source dwell position, source dwell time, source activity)
19

Utilisation d'atlas anatomiques et de modèles déformables pour la segmentation de la prostate en IRM

Martin, Sébastien 17 December 2008 (has links) (PDF)
Le principal objectif de cette thèse est le développement d'outils permettant le contourage automatique de la prostate en IRM. Dans un futur proche, ces outils s'intègreront à des systèmes informatiques permettant d'assister le clinicien dans la réalisation du geste de curiethérapie de la prostate. Notre méthode se base sur l'utilisation d'un atlas anatomique et de modèles déformables pour réaliser une segmentation automatique de la prostate. La méthode se déroule suivant une approche hiérarchique en 3 étapes permettant d'intégrer efficacement différents types de connaissances a priori. Une première étape de pré-traitements permet la correction des très fortes inhomogénéités d'intensités caractéristiques des images IRM acquises par l'intermédiaire de sondes endorectales. Dans une seconde étape, l'anatomie du patient est mise en correspondance avec un atlas anatomique ; ce qui permet d'obtenir une première segmentation du rectum et de la prostate. Enfin, dans une dernière étape, deux modèles déformables évoluent successivement pour raffiner les segmentations précédemment obtenues. Dans un premier temps, le rectum est segmenté suivi de la prostate. L'intégration du rectum dans le processus de segmentation permet de contraindre l'évolution du modèle déformable de la prostate. L'atlas anatomique utilisé est construit grâce à un algorithme de recalage hybride permettant la mise en correspondance d'une population sur une référence. L'algorithme hybride en exploitant conjointement des informations géométriques et iconiques permet la construction d'atlas qui se sont avérés plus performants que ceux construits par un recalage iconique pur.
20

Multimodal Image Registration in Image-Guided Prostate Brachytherapy / Recalage d'images multimodales en curiethérapie de la prostate

Hamdan, Iyas 17 January 2017 (has links)
Le cancer de la prostate est le cancer le plus fréquent chez l'homme en France et aux pays occidentaux. Il est la troisième cause de décès liés au cancer, étant responsable d'environ 10% des morts. La curiethérapie, une technique de radiothérapie, est liée à une meilleure qualité de vie après le traitement, par rapport aux autres méthodes de traitement. La curiethérapie de la prostate consiste à insérer des sources radioactives dans la prostate afin de délivrer une dose d'irradiation localisée à la tumeur tout en protégeant les tissus sains environnants. L'imagerie multimodale est utilisée afin d'améliorer la précision du traitement. Les images Tomodensitométriques préopératoires, appelées Computed Tomography (CT), peuvent être utilisées pour calculer une distribution personnalisée et plus précise de dose. Pendant l'intervention, le chirurgien utilise un système de guidage temps-réel par l'Ultrason Transrectale, Transrectal Ultrasound (TRUS), pour placer correctement les sources radioactives dans leurs positions souhaitées. Par conséquent, si les positions des sources sont déterminées sur l'image CT, elles doivent être transférées à l'image US. Cependant, un recalage US/CT direct et robuste est difficilement envisageable parce que les tissus mous, telle que la prostate, offrent peu de contraste en CT et en US. En revanche, l'Imagerie par Résonance Magnétique (IRM) fournit un meilleur contraste et peut, potentiellement, améliorer le traitement en améliorant la visualisation. Donc, ces trois modalités (IRM, CT et US) doivent être correctement alignées. Pour compenser les déformations de la prostate, due au changement de taille et forme entre les différentes acquisitions, un recalage non-rigide est nécessaire. Une méthode de recalage entièrement automatique est nécessaire, afin de faciliter son intégration au bloc opératoire. Nous proposons dans un premier temps un recalage IRM/CT basé sur la maximisation de l'information mutuelle en combinaison avec un champ de déformation paramétré par B-Splines. Nous proposons de contraindre le recalage sur des volumes d'intérêt (VOIs) afin d'améliorer la robustesse et le temps de calcul. L'approche proposée a été validée sur des jeux de données cliniques. Une évaluation quantitative a montré que l'erreur de recalage est égale à 1.15±0.20 mm; qui répond à la précision clinique souhaitée. Ensuite, nous proposons un deuxième recalage US/IRM, où nous utilisons une approche multi-résolution pour éviter les minima locaux et améliorer le temps de calcul. Un critère de similarité, qui met en corrélation l'intensité de l'image US avec l'intensité ainsi que le gradient de l'image IRM, a été utilisé afin de trouver la transformation qui aligne les deux images. Cette méthode a été validée sur un fantôme de prostate dans un premier temps pour évaluer sa faisabilité. Ensuite, elle a été validée sur des jeux de données cliniques en utilisant des critères qualitatives et quantitatives. La distance Hausdorff a montré que l'erreur de recalage est égale à 1.44±0.06 mm. L'approche proposée dans ce travail permet d'aller vers un protocole de curiethérapie guidée par l'imagerie multimodale qui puisse améliorer la précision globale de cette procédure. Malgré ces résultats plutôt encourageants, les travaux futurs impliqueront une évaluation plus approfondie sur plus de jeux de données afin d'évaluer la fiabilité et l'efficacité de cette méthode avant de l'intégrer au bloc opératoire. / Prostate cancer is the most common cancer in men in France and western countries. It is the third leading cause of death from cancer, being responsible for around 10% of deaths. Brachytherapy, a radiotherapy technique, is associated with a better health-related quality of life after the treatment, compared to other treatment techniques. Prostate brachytherapy involves the implantation of radioactive sources inside the prostate to deliver a localized radiation dose to the tumor while sparing the surrounding healthy tissues. Multi-modal imaging is used in order to improve the overall accuracy of the treatment. The pre-operative Computed Tomography (CT) images can be used to calculate a personalized and accurate dose distribution. During the intervention, the surgeon utilizes a real-time guiding system, Trasnrectal Ultrasound (TRUS), to accurately place the radioactive sources in their desired pre-planned positions. Therefore, if the positions of the sources were determined on CT, they need to be transferred to US. However, a robust and direct US/CT registration is hardly possible since they both provide low soft tissue contrast. Magnetic Resonance Imaging (MRI), on the other hand, has a superior contrast and can potentially improve the treatment planning and delivery by providing a better visualization. Thus, these three modalities (MRI, US and CT) need to be accurately registered. To compensate for prostate deformations, caused by changes in size and form between the different acquisitions, non-rigid registration is essential. Fully automatic registration methodology is necessary in order to facilitate its integration in a clinical workflow. At first, we propose a registration between pre-operative MR and CT images based on the maximization of the mutual information in combination with a deformation field parameterized by cubic B-Splines. We propose to constrain the registration to volumes of interest (VOIs) in order to improve the robustness and the computational efficiency. The proposed approach was validated on clinical patient datasets. Quantitative evaluation indicated that the overall registration error was of 1.15±0.20 mm; which satisfies the desired clinical accuracy. Then, we propose a second intra-operative US/MRI registration, where a multi-resolution approach is implemented to reduce the probability of local minima and improve the computational efficiency. A similarity measure, which correlates intensities of the US image with intensities and gradient magnitude of the MRI, is used to determine the transformation that aligns the two images. The proposed methodology was validated on a prostate phantom at first to assess its feasibility. Subsequently, the method was validated on clinical patient datasets and evaluated using qualitative and quantitative criteria, resulting in a registration error of 1.44±0.06 mm. The approach proposed in this work allows going towards a multimodal protocol for image-guided brachytherapy which can improve the overall accuracy of this procedure. Despite such encouraging results, future work will involve further evaluation on a larger number of datasets in order to assess the reliability and the efficiency of this methodology before integrating it in a clinical workflow.