1

Etude théorique et expérimentale des implants médicaux actifs en environnement électromagnétique : application aux défibrillateurs implantables en champ magnétique basse fréquence dans la bande 50Hz - 50kHz / Experimental and theoretical modelling of active medical implants within an electromagnetic environment : Application to implantable defibrillators in the 50 hz-50 khz range

Katrib, Juliano 13 October 2011 (has links)
Ce travail de thèse s'inscrit dans un contrat entre l'équipe "Mesures électroniques" du LIEN (EA3440) et le service de la Recherche et celui des Études Médicales de la société EDF. Il porte sur le comportement des défibrillateurs implantables en environnement magnétique basse fréquence (50 Hz-50 kHz). Un premier chapitre introduit les principes des interactions entre les champs électromagnétiques et les implants médicaux actifs. Il résume les données constitutives d'une étude comportementale des implants médicaux actifs en présence d'un champ électromagnétique. Y sont présentées et définies les données générales ou spécifiques aux sources électromagnétiques et aux dispositifs médicaux implantables. Un souci est de déterminer les champs et/ou les courants électriques induits dans un modèle du corps humain par une source magnétique basse fréquence (50 Hz à 50 kHz), c'est l'objet du chapitre 2. Ces calculs sont basés sur un modèle par les intégrales finies simulé à l'aide du logiciel CST. Un fantôme virtuel utilisant les conductivités de 77 organes différents a été construit grâce au Visible Human Project. La prise en compte de l'implant est effectuée au chapitre 3. Partant des résultats précédents, un défibrillateur implantable est inséré dans le modèle virtuel en vue de calculer les tensions induites en bout de sonde. Ces tensions sont comparées aux données normatives et montrent leur valeur très faibles quelle que soit la fréquence du champ magnétique. Le quatrième et dernier chapitre présente les résultats de validation expérimentale obtenues par des tests in vitro dans un fantôme électromagnétique au sein d'une cage de Faraday. Un signal cardiaque leurre est généré artificiellement. Un banc de mesure est configuré et géré par un logiciel d'instrumentation virtuelle sous GPIB (HPVEE). Il permet de contrôler la puissance de la source et de recueillir les signaux via la télémétrie du défibrillateur. Quelques épisodes réversibles ont été observés à 50 Hz montrant la grande sensibilité de l'électronique (filtre d'entrée) selon les modèles destinés à l'Europe (50 Hz) ou aux USA (60 Hz). Ceci est normal ces valeurs correspondant aux fréquences cardiaques. Les séries de mesures effectuées n'ont montré aucune défaillance pour les 4 défibrillateurs testés pour des puissances pouvant atteindre jusqu'à 3,44 mT. / This thesis was conducted under a contract between the "Electronic Measurements" Research Group within the Electronic Instrumentation Laboratory of Nancy and the Research Department of EDF. The focus of this thesis is the behavior of implantable defibrillators in low frequency (50 Hz-50 kHz) magnetic environments. The first chapter introduces the principles and summarizes the basics of the interactions between electromagnetic fields and active medical implants. General and specific data concerning implantable medical devices are also presented. The main aim of the second chapter is to determine the fields and/or electric currents induced in a human body by a magnetic source at low frequency (50 Hz to 50 kHz). The calculations are based on a finite integral method elements model using CST software. In the third chapter, a virtual phantom is described, based on 77 different organs. It is constructed using the Virtual Family. Based on the above results, an implantable defibrillator is inserted into the virtual model to calculate the voltages induced at the end of the probe. These voltages are compared with threshold values obtained from the Standards to demonstrate their very low values regardless of the frequency of the magnetic field. The fourth and final chapter presents the results obtained for experimental validation with in vitro tests in an electromagnetic phantom made of gelatin, placed within a Faraday cage. A cardiac signal is generated as an artificial lure. The experimental set up is configured and managed by virtual instrumentation (GPIB HPVEE). It controls the power source and collects telemetry signals via the defibrillator. Some reversible episodes were observed at 50 Hz showing the sensitivity of the electronics (input filter) according to the ICD models destined for Europe (50 Hz) and the USA (60 Hz). These are normal values for heart rate. The series of measurements showed no failure for four defibrillators tested in electromagnetic fields up to 3.44 mT
2

Estimation du risque de mort subite par arrêt cardiaque a l'aide de méthodes d'apprentissage artificiel / Risk stratification for sudden cardiac death based on machine learning

Cappelaere, Charles-Henri 31 January 2014 (has links)
Depuis le début des années 2000, le défibrillateur automatique implantable (DAI) est prescrit de manière prophylactique aux populations à risque de mort subite. Nombre de ces implantations semblent prématurées, ce qui pose problème en raison des complications post-opératoires encourues. Il apparaît donc important de mieux définir la population à risque de mort subite, afin d'optimiser la sélection des patients.Le pouvoir prédictif de mort subite des différents descripteurs du Holter a fait l'objet de nombreuses études univariées, sans permettre d'amélioration des critères de sélection. Dans ce mémoire, nous présentons l'analyse multivariée des descripteurs du Holter que nous avons menée. Nous avons extrait l'ensemble des descripteurs calculables sur la base étiquetée d'enregistrements de patients, victimes ou non d'arythmies traitées par le DAI, dont nous disposons. À l'aide de connaissances physiologiques sur l'arythmogenèse, nous avons réalisé une sélection des descripteurs les plus pertinents. Puis, par une méthode originale de conception et d'évaluation de classifieur, nous avons construit un classifieur ad hoc, basé, sur les connaissances physiologiques de l'arythmogenèse ; ce classifieur discrimine les patients à risque, des patients pour lesquels l'implantation ne paraît pas opportune.Au vu des performances atteintes, il semble possible d'améliorer la fiabilité des indications d'implantation prophylactique, à l'aide de méthodes d'apprentissage statistique. Pour valider cette conclusion, il paraît néanmoins nécessaire d'appliquer la méthode exposée dans la présente étude à une base de données de plus grande dimension, et de contenu mieux adapté à nos objectifs. / Implantable cardioverter defibrillators (ICD) have been prescribed for prophylaxis since the early 2000?s, for patients at high risk of SCD. Unfortunately, most implantations to date appear unnecessary. This result raises an important issue because of the perioperative and postoperative risks. Thus, it is important to improve the selection of the candidates to ICD implantation in primary prevention. Risk stratification for SCD based on Holter recordings has been extensively performed in the past, without resulting in a significant improvement of the selection of candidates to ICD implantation. The present report describes a nonlinear multivariate analysis of Holter recording indices. We computed all the descriptors available in the Holter recordings present in our database. The latter consisted of labelled Holter recordings of patients equipped with an ICD in primary prevention, a fraction of these patients received at least one appropriate therapy from their ICD during a 6-month follow-up. Based on physiological knowledge on arrhythmogenesis, feature selection was performed, and an innovative procedure of classifier design and evaluation was proposed. The classifier is intended to discriminate patients who are really at risk of sudden death from patients for whom ICD implantation does not seem necessary. In addition, we designed an ad hoc classifier that capitalizes on prior knowledge on arrhythmogenesis. We conclude that improving prophylactic ICD-implantation candidate selection by automatic classification from Holter recording features may be possible. Nevertheless, that statement should be supported by the study of a more extensive and appropriate database.
3

Mort subite de l'adulte : stratégie de déploiement des défibrillateurs automatisés externes

Dahan, Benjamin 21 November 2016 (has links)
L’arrêt cardiaque extra-hospitalier (ACEH) est un problème de santé publique majeur. La réanimation cardio-pulmonaire (RCP) précoce ainsi que la défibrillation par les témoins sont associées à une augmentation du taux de survie. Cependant, malgré d’importants efforts ces dernières années, les taux de survie restent faibles dans la plupart des pays. Ce travail avait pour objectif d’identifier des facteurs ayant un impact sur la défibrillation publique, la RCP précoce et les connaissances du public sur la défibrillation. Nous avons testé différentes stratégies de déploiement des défibrillateurs automatisés externes (DAE). Nous avons également analysé l’effet du niveau socio-économique des quartiers sur la RCP par les témoins. Enfin, nous avons cherché à évaluer les connaissances du public concernant la localisation et les conditions d’utilisation du DAE le plus proche dans des lieux publics très fréquentés. Tous les ACEH survenus à Paris entre 2000 et 2010 ont été enregistrés dans un registre et géocodés. Nous avons comparé une stratégie basée sur les recommandations de placement d’un DAE dans les lieux où plus d’un ACEH survenait tous les cinq ans à deux nouvelles stratégies : une stratégie de maillage régulier du territoire avec des DAE placés à distances régulières et une stratégie de placement dans différents types de lieux publics. Le nombre de DAE nécessaires ainsi que la distance médiane entre les ACEH et le DAE le plus proche étaient calculés pour chaque stratégie. Nous avons également recherché l’association entre le niveau socio-économique des quartiers sur le fait de bénéficier d’une RCP. Enfin, nous avons réalisé une enquête dans des lieux publics très fréquentés (gare, centres commerciaux, jardin public) auprès de toutes les personnes situées dans un rayon de 100 mètres autour d’un DAE pour analyser leur connaissance de la localisation du DAE et leur capacité à l’utiliser. Parmi 4176 ACEH, 1372 (33%) sont survenus dans des lieux publics. La stratégie basée sur les recommandations aurait conduit au placement de 170 DAE avec une distance aux ACEH de 416 (180-614) mètres et une augmentation continue du nombre de DAE. Avec la stratégie de maillage régulier du territoire, le nombre de DAE et la distance aux ACEH auraient changé selon la taille du maillage avec un nombre optimal de DAE évalué entre 200 et 400. Avec la stratégie de placement dans différents types de lieux publics, la distance médiane entre les ACEH et les DAE aurait été de 324 mètres pour les bureaux de poste (195), 239 mètres pour les stations de métro (302), 137 mètres pour les stations Velib’ (957) et 142 mètres pour les pharmacies (1466). Parmi les 4009 ACEH géocodables enregistrés, 777 (19,4%) ont bénéficié d’une RCP par un témoin. Ceux qui en ont bénéficié étaient plus fréquemment dans un lieu public, en présence d’un témoin et dans un quartier de statut socio-économique (SSE) non défavorisé. Dans une analyse multiniveaux la RCP par les témoins était significativement moins fréquente dans les quartiers de SSE défavorisé que dans les quartiers d’autres SSE (OR 0,85 ; 95% IC 0,72-0,99). Notre enquête a été menée auprès de 301 participants. Environ la moitié des participants (49%) avaient bénéficié d’une formation aux premiers secours, dont 70% après 2007 et 37% qui avaient suivi une initiation d’une heure. Le logo universel des DAE était reconnu par 37% des participants et 64% pouvaient reconnaître un DAE en photo. La localisation du DAE le plus proche était connue par 16% des participants avec un impact positif des formations après 2007 et de la reconnaissance du logo ou des photos (p<0,0001). Une majorité de participants (66%) savaient qu’ils avaient le droit d’utiliser un DAE et 59% savaient dans quelles circonstances l’utiliser. Seulement 25% des participants déclaraient savoir comment utiliser un DAE. Notre travail présente une approche originale pour optimiser les stratégies de déploiement des DAE. (...) / Out-of-hospital cardiac arrest (OHCA) is a major public health concern. Early bystander cardiopulmonary resuscitation (CPR) and defibrillation are associated with higher survival rates for OHCA victims. Unfortunately, despite major efforts over the past decade, survival rates remain low in many communities. This work sought to highlight factors affecting public defibrillation, early CPR and public knowledge on defibrillation. We assessed different strategies for Automated External Defibrillators (AEDs) deployment. We also aimed to focus effect of neighborhood socio-economic status on bystander CPR. Finally, we sought to analyze public awareness of the AED nearest location and knowledge of AED use. All OHCAs attended by EMS in Paris between 2000 and 2010 were prospectively recorded and geocoded. We compared a guidelines-based strategy of placing an AED in locations where more than one OHCA had occurred within the past five years to two novel strategies: a grid-based strategy with a regular distance between AEDs and a landmark-based strategy. The expected number of AEDs necessary and their median (IQR) distance to the nearest OHCA were assessed for each strategy. We also evaluated the relationship between neighbourhood SES characteristics and the fact of receiving bystander CPR. Then, we performed a survey in three kinds of places (train station, city mall and public park) of all individuals within 100 meters from an AED to analyze their knowledge of the closest AED location and their confidence to use it. Of 4,176 OHCAs, 1,372 (33%) occurred in public settings. The guidelines-based strategy would result in the placement of 170 AEDs, with a distance to OHCA of 416 (180-614) meters and a continuous increase in the number of AEDS. In grid-based strategy, the number of AEDs and their distance to the closest OHCA would change with the grid size, with a number of AEDs between 200 and 400 seeming optimal. In landmark-based strategy, median distances between OHCAs and AEDs would be 324 meters if placed at post offices (n=195), 239 at subway stations (n=302), 137 at bike-sharing stations (n=957), and 142 at pharmacies (n=1466). Of the 4,009 OHCA with mappable addresses recorded, 777 (19.4%) received bystander CPR. Those receiving it were more likely to be in public locations, have had a witness to their OHCA, and to have collapsed in a non-low SES neighbourhood. In a multilevel analyses, bystander CPR provision was significantly less frequent in low than in higher SES neighbourhoods (OR 0.85; 95% confidence interval [CI] 0.72-0.99). A total of 301 people responded to the survey. About half respondents (49%) had a Basic Life Support training experience with 70 % of them trained after 2007 and 37% who attempted a one hour training initiation. The universal AED sign was recognized by 37% of all respondents and 64% could recognize an AED on a picture. The closest AED location was known by 16% of the respondents with a positive impact of training after 2007 and knowledge of AED sign and picture (p<0.0001). A majority of respondents (66%), considered they had the right to use an AED and 59% knew in which circumstances it is necessary to use it. Only 25% of the respondents declared to know how to use an AED. Our work presents an original evidence-based approach to strategies of AED deployment to optimize their number and location. This rational approach can estimate the optimal number of AEDs for any city. In Paris, OHCA victims were less likely to receive bystander CPR in low SES neighbourhoods. These first European data are consistent with observations in North America and Asia. Our survey conducted in places known to be at risk of OHCA highlights the need for a better AED visibility in public places and the need to improve public knowledge and confidence in the use of AED. (...)
4

Évaluation d’une intervention infirmière basée sur une approche caring et cognitive comportementale sur l’acceptation d’un défibrillateur cardiaque implantable

Charchalis, Mélanie 08 1900 (has links)
Le taux de mortalité chez les patients à risque d’arythmies cardiaques menaçantes à la vie a été considérablement réduit grâce au défibrillateur cardiaque implantable (DCI). Toutefois, des préoccupations uniques face au DCI, y compris les chocs que l’appareil peut déclencher, sont susceptibles de provoquer des symptômes d'anxiété et une limitation perçue des activités chez les porteurs de DCI. Ces réactions émotives et modifications de comportement peuvent affecter l’acceptation du patient envers le DCI. Cette étude pilote randomisée avec groupe contrôle (n=15 /groupe) visait à examiner la faisabilité et l'acceptabilité d'une intervention infirmière individualisée de même que ses effets préliminaires sur l’anxiété, le fonctionnement dans les activités de la vie quotidienne et l’acceptation du DCI auprès de nouveaux porteurs de DCI. L'intervention infirmière, basée sur la théorie du Human Caring et teintée d’une approche cognitive comportementale, ciblait les préoccupations individuelles face au DCI. À partir des préoccupations identifiées, l’infirmière intervenait en mettant l'accent sur les croyances contraignantes du patient, qui pouvaient mener à de l’anxiété et des comportements d'évitement. Après randomisation, les patients du groupe intervention (GI) ont participé à un premier entretien en face-à-face avant le congé hospitalier. Subséquemment, deux entretiens se sont faits par téléphone, à environ 7 et 14 jours suite au congé hospitalier. Les résultats soutiennent la faisabilité et l’acceptabilité du devis de l’étude et de l’intervention évaluée. De plus, ils soulignent le potentiel de l’intervention à diminuer les sentiments anxieux chez les participants du GI. Les résultats de cette étude pilote offrent des pistes de recherches futures et permettront de guider la pratique clinique. / Patients with an implantable cardiac defibrillator (ICD) decrease their risk of mortality related to life threatening arrhythmias. However, multiple concerns about this device exist, including ICD shocks, which may result in increased anxiety and a perceived limitation in performing everyday activities. These emotional reactions and behavioral changes may have a negative impact on the acceptance of the device. The purpose of this randomized pilot study with a group control (n=15 / group), was to verify the feasibility and acceptability of an individualized nursing intervention aiming to decrease anxiety, improve performance in everyday activities and device acceptance in patients with newly implanted ICDs. Based on Human Caring theory and a cognitive behavioral approach, this intervention addressed each patient’s unique concerns. From the identified concerns, the nurse intervened focussing on the patient’s dysfunctional beliefs that can lead to anxiety and avoidance behavior. After randomization, the first encounter for the experimental group (EG) was face-to-face before hospital discharge. Subsequently, two encounters were made via telephone, 7 and 14 days after discharge. The results support the feasibility and acceptability of the study design and the intervention evaluated. In addition, they emphasize the potential of the intervention to reduce symptoms of anxiety among the participants of the EG. The results of this pilot study may provide directions for future research and help guide clinical practice.
5

Évaluation de l’hémodynamique systémique lors de l’arrêt cardiaque par analyse des signaux recueillis par un défibrillateur / Circulation detection during out of hospital cardiac arrest using the biological signals recorded by a defibrillator

Neyton, Clément 24 September 2018 (has links)
Afin d’apporter les soins adéquats aux victimes d'arrêt cardiaque extrahospitalier, l'évaluation de leur état hémodynamique est primordiale. La prise de pouls manuelle ne permet pas une identification fiable de l'arrêt cardiaque par les profanes ou une discrimination des rythmes organisés par les premiers intervenants. Dans ce contexte, l'entreprise Schiller Médical a cherché à intégrer dans sa gamme de défibrillateurs un module de détection de l'hémodynamique systémique par analyse de l'électrocardiogramme et des variations d'impédance transthoracique recueillis via les électrodes de défibrillation. Ce travail de recherche mené en partenariat entre l'entreprise Schiller Médical et l'Institut Pluridisciplinaire Hubert Curien de l’Université de Strasbourg a consisté dans un premier temps a recherché, lors d'arrêt cardiaque induit électriquement chez l'homme, des descripteurs des variations d'impédance transthoracique marqueurs de l’hémodynamique systémique. L’identification des descripteurs les plus pertinents a par la suite permis de construire des modèles prédictifs des défaillances circulatoires. Nous avons mis en lumière des limites à l’utilisation des variations d’impédance transthoracique. Elles sont prises en considération pour la documentation des interventions extrahospitalières destinée à l’apprentissage des algorithmes de classification des rythmes perfusants et rythmes sans pouls. / Providing suitable emergency care during out of hospital cardiac arrest requires the diagnostic of the circulatory status. Manual pulse check does not provide a reliable way for laypersons to identify cardiac arrest or for first responders to discriminate organized rhythms. Thus, Schiller Medical sought to embed an hemodynamic sensor in its external defibrillators by analyzing the electrocardiogram and transthoracic impedance recorded via the defibrillation pads. This thesis work stemmed from a partnership between Schiller Medical and the Institut Pluridisciplinaire Hubert Curien of the Université de Strasbourg. We first identified transthoracic impedance featureslinked with the circulatory status by studying clinically induced cardiac arrest. The most relevant features were later selected to form predictive models of hemodynamic collapse. We uncovered restrictions to the use of transthoracic impedance. We took them into account for the annotation of out of hospital cardiac arrests aimed at training algorithms for the classification of pulseless electrical activity and pulsatile rhythms.
6

Immunité des implants cardiaques actifs aux champs électriques de 50/60 Hz / Immunity of active implantable cardiac devices at 50/60 Hz electric field

Gercek, Cihan 28 November 2016 (has links)
La directive européenne 2013/35/UE précise les exigences minimales pour la protection des travailleurs exposés aux champs électromagnétiques et définit les porteurs d’implants comme travailleurs à risques particuliers. Concernant les porteurs de défibrillateur automatique implantable (DAI) ou de stimulateur cardiaque (SC), l’exposition au champ électrique ou magnétique d’extrêmement basse fréquence crée des inductions à l'intérieur du corps humain pouvant générer une tension perturbatrice susceptible de causer le dysfonctionnement de l’implant. Le sujet de ce travail de thèse porte sur la compatibilité électromagnétique des implants cardiaques soumis à un champ électrique basses fréquences (50/60 Hz). Des simulations numériques ont été effectuées afin de concevoir un banc expérimental pour l’exposition de fantômes incluant des stimulateurs ou des défibrillateurs implantables. Une étude expérimentale a permis d’établir par provocation les seuils de champ électrique permettant d’éviter tout dysfonctionnement éventuel de l’implant. Dans la partie simulation numérique ; un modèle humain virtuel (fantôme numérique contenant un implant cardiaque) a été placé en position debout sous une exposition verticale à un champ électrique. La méthode des éléments finis a été utilisée pour définir les phénomènes induits au niveau de l’implant cardiaque avec une résolution de 2mm (logiciel CST®). Dans la partie expérimentale, un banc d'essai dimensionné pour permettre de générer un champ électrique pouvant atteindre 100 kV/m aux fréquences 50-60 Hz a été conçu, optimisé et réalisé afin d’analyser le comportement des implants cardiaques. Plusieurs configurations ont été étudiées. Sur 54 implants cardiaques actifs testés (43 stimulateurs et 11 défibrillateurs) à des niveaux de champs électriques très élevés (100 kV/m) générés par notre dispositif expérimental, aux fréquences de 50-60 Hz, aucune défaillance n’a été observée pour des niveaux d’exposition publics et pour la plupart des configurations (+99%) sauf pour six stimulateurs cardiaques dans le cas d’une configuration « pire cas » peu réaliste en clinique : mode unipolaire avec une sensibilité maximale et en détection auriculaire. Les implants configurés avec une sensibilité nominale en mode bipolaire résistent bien à des champs électriques dépassant les valeurs seuils telles que définies par 2013/UE/35. / The European Directive 2013/ 35 / EU specify minimum requirements for the protection of workers exposed to electromagnetic fields and define with implants as “workers at particular risk”. Regarding the implantable cardioverter defibrillator wearers (ICD) or pacemaker (PM), exposure to electric or magnetic field of extremely low frequency creates inductions inside the human body that generate interference voltage which may cause the dysfunction of the implant. This thesis investigates the electromagnetic compatibility of cardiac implants subjected to an electric field low frequency (50/60 Hz). Computational simulations are effectuated in order to design an experimental bench for the exposure of a phantom including pacemakers or implantable defibrillators. A provocative study is established to define the electric field thresholds for preventing any malfunction of the implant. In numerical simulations; a virtual human model (digital phantom containing a cardiac implant) was placed in an upright position in a vertical exposure to an electric field. The finite element method was used to define the inductions in the cardiac implant level with a resolution of 2 mm (CST® software). In the experimental part, a test bench designed to allow generating an electric field up to 100 kV / m at frequencies 50-60 Hz was constructed, optimized and employed to investigate the behavior of cardiac implants.Several configurations were studied. 54 active cardiac implants (43 pacemakers and 11 defibrillators) are submitted to very high electric field of 50-60 Hz (up to 100 kV / m) inside the experimental bench. No failure was observed for public exposure levels for most configurations (+ 99%) except for six pacemakers in the case of a configuration clinically almost inexistent: unipolar mode with maximum sensitivity and atrial sensing.The implants configured with a nominal sensitivity in bipolar mode are resistant to electric fields exceeding the low action levels (ALs), even for the most high ALs, as defined by 2013 / 35 / EU
7

Évaluation d’une intervention infirmière basée sur une approche caring et cognitive comportementale sur l’acceptation d’un défibrillateur cardiaque implantable

Charchalis, Mélanie 08 1900 (has links)
Le taux de mortalité chez les patients à risque d’arythmies cardiaques menaçantes à la vie a été considérablement réduit grâce au défibrillateur cardiaque implantable (DCI). Toutefois, des préoccupations uniques face au DCI, y compris les chocs que l’appareil peut déclencher, sont susceptibles de provoquer des symptômes d'anxiété et une limitation perçue des activités chez les porteurs de DCI. Ces réactions émotives et modifications de comportement peuvent affecter l’acceptation du patient envers le DCI. Cette étude pilote randomisée avec groupe contrôle (n=15 /groupe) visait à examiner la faisabilité et l'acceptabilité d'une intervention infirmière individualisée de même que ses effets préliminaires sur l’anxiété, le fonctionnement dans les activités de la vie quotidienne et l’acceptation du DCI auprès de nouveaux porteurs de DCI. L'intervention infirmière, basée sur la théorie du Human Caring et teintée d’une approche cognitive comportementale, ciblait les préoccupations individuelles face au DCI. À partir des préoccupations identifiées, l’infirmière intervenait en mettant l'accent sur les croyances contraignantes du patient, qui pouvaient mener à de l’anxiété et des comportements d'évitement. Après randomisation, les patients du groupe intervention (GI) ont participé à un premier entretien en face-à-face avant le congé hospitalier. Subséquemment, deux entretiens se sont faits par téléphone, à environ 7 et 14 jours suite au congé hospitalier. Les résultats soutiennent la faisabilité et l’acceptabilité du devis de l’étude et de l’intervention évaluée. De plus, ils soulignent le potentiel de l’intervention à diminuer les sentiments anxieux chez les participants du GI. Les résultats de cette étude pilote offrent des pistes de recherches futures et permettront de guider la pratique clinique. / Patients with an implantable cardiac defibrillator (ICD) decrease their risk of mortality related to life threatening arrhythmias. However, multiple concerns about this device exist, including ICD shocks, which may result in increased anxiety and a perceived limitation in performing everyday activities. These emotional reactions and behavioral changes may have a negative impact on the acceptance of the device. The purpose of this randomized pilot study with a group control (n=15 / group), was to verify the feasibility and acceptability of an individualized nursing intervention aiming to decrease anxiety, improve performance in everyday activities and device acceptance in patients with newly implanted ICDs. Based on Human Caring theory and a cognitive behavioral approach, this intervention addressed each patient’s unique concerns. From the identified concerns, the nurse intervened focussing on the patient’s dysfunctional beliefs that can lead to anxiety and avoidance behavior. After randomization, the first encounter for the experimental group (EG) was face-to-face before hospital discharge. Subsequently, two encounters were made via telephone, 7 and 14 days after discharge. The results support the feasibility and acceptability of the study design and the intervention evaluated. In addition, they emphasize the potential of the intervention to reduce symptoms of anxiety among the participants of the EG. The results of this pilot study may provide directions for future research and help guide clinical practice.
8

Vers une meilleure identification des patients à risque d’arythmies ventriculaires en cardiopathie arythmogène du ventricule droit

Cadrin-Tourigny, Julia 06 1900 (has links)
Introduction : La cardiopathie arythmogène du ventricule droit (CAVD) est une pathologie d’origine génétique se traduisant par un remplacement cicatriciel qui affecte de façon prédominante le ventricule droit (VD). Le diagnostic est complexe car il repose sur un ensemble de critères cliniques plutôt que sur un seul test diagnostic. L’atteinte du VD se traduit de façon prédominante par des arythmies ventriculaires qui peuvent parfois conduire à la complication la plus redoutée de cette affection : la mort subite. La prédiction et la prévention de celle-ci sont des enjeux cruciaux de la prise en charge de cette maladie. Objectifs : Ce travail vise à améliorer la prise en charge des patients atteints de CAVD de deux façons distinctes. Premièrement, en tentant de faciliter le diagnostic par la validation des critères diagnostiques en vigueur. Deuxièmement, en améliorant la stratification du risque d’arythmie ventriculaires soutenues et plus spécifiquement celui de la mort subite et des arythmies potentiellement mortelles (tachycardie ventriculaire > 250 bpm, fibrillation ventriculaire) en créant des modèles de prédiction du risque permettant de déterminer le risque individuel de chaque patient. Résultats : Article 1 - Un total de 407 patients consécutifs référés pour une résonnance magnétique cardiaque pour suspicion de CAVD ont été inclus. De ceux-ci, 66 (16%) ont reçu un diagnostic définitif selon le critère de référence établi pour cette étude: le consensus d’un panel d’experts. Globalement, les critères performent bien avec une sensibilité et spécificité à 92%. Cependant, certains critères tels l’ECG haute amplitude (SAECG) et certains critères reliés à l’histoire familiale ne sont pas discriminants. Le retrait de ces critères pourrait réduire le nombre de faux positifs sans pour autant augmenter le nombre de faux négatifs (net reclassification improvement de 4,3%, p=0,019). De plus, la combinaison des critères électrocardiographiques et de la présence d’arythmies ventriculaires a une sensibilité de 100%, ce qui peut faciliter dans certains cas le dépistage en limitant la nécessité de recourir à l’imagerie. Pour les articles 2 et 3, une base de données incluant des patients avec un diagnostic définitif de CAVD a été assemblée à partir de bases de données provenant de six pays (Canada, États-Unis, Pays-Bas, Suède, Norvège, Suisse). Article 2 - Un total de 528 patients sans histoire antérieure d’arythmies ventriculaires soutenues a été inclus pour développer un modèle de prédiction de risque. De ceux-ci, 146 (27,7%) ont subi un événement arythmique durant un suivi médian de 4,8 ans. Des huit prédicteurs initialement identifiés (âge inférieur au diagnostic, sexe masculin, syncope cardiaque récente, nombre de dérivations avec des inversions des ondes T, fardeau d’extrasystoles ventriculaires (ESV) en 24h, tachycardie ventriculaire non-soutenue et fractions d’éjection des ventricules gauche et droit), sept ont été retenus dans le modèle, excluant seulement la fraction d’éjection du ventricule gauche (FEVG). Le modèle peut distinguer adéquatement entre les patients avec et sans événement (C-index de 0,77) avec un optimisme minimal (courbe de calibration de 0,93). L’utilisation de cet algorithme permettrait de réduire l’utilisation de défibrillateurs implantables de 20% par rapport à l’algorithme du consensus le plus largement utilisé. Article 3 - Une cohorte de 864 patients incluant à la fois ceux avec et sans histoire antérieure d’arythmie ventriculaire soutenue a été assemblée. Durant un suivi médian de 5,75 ans, 93 patients ont eu un épisode d’arythmie rapide selon la définition préalablement établie. Des huit facteurs de risque cités ci-haut, seulement quatre ont été retenus dans le modèle : l’âge plus jeune au diagnostic, sexe masculin, fardeau d’ESV en 24h et nombre de dérivations avec des inversions des ondes T. Fait à noter, les événements antérieurs ne se sont pas avérés prédicteurs d’arythmies potentiellement mortelles subséquentes. Le modèle peut distinguer adéquatement entre les patients avec et sans événement (C-index de 0,74) et présente un optimisme minimal avec une courbe de calibration de 0,95. Conclusion : Bien que les critères diagnostiques en vigueur pour la CAVD aient une performance adéquate, ceux-ci peuvent être simplifiés et améliorés par le retrait de certains de ces critères. L’absence de critères électrocardiographiques combinés et d’arythmies ventriculaires peut exclure une CAVD, ce qui peut en simplifier le dépistage. Chez les patients atteints de CAVD, la prédiction du risque et la sélection des patients pour l’implantation d’un défibrillateur peuvent être facilités grâce à deux modèles complémentaires de prédiction du risque permettant de prédire les événements arythmiques soutenus dans le premier et plus spécifiquement les arythmies ventriculaires potentiellement mortelles dans le deuxième. Ces outils sont particulièrement utiles dans une approche de prise de décision partagée. / Introduction: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetic pathology resulting in a fibro-fatty replacement predominantly affecting the right ventricle. The diagnosis is complex and is based on a set of clinical criteria. Involvement of the right ventricle predominantly results in ventricular arrhythmias which constitutes the most common presentation but can also lead to the most feared consequence: sudden cardiac death. Predicting and preventing this catastrophic outcome are crucial in the management of this disease. Objectives: This work aims to improve the management of patients with ARVC in two distinct ways. First, by attempting to facilitate the diagnosis by validating the currently used diagnostic criteria. Second by improving risk stratification for sustained ventricular arrhythmias and specifically life-threatening ventricular arrhythmias (LTVA defined as ventricular tachycardia > 250 bpm, ventricular fibrillation, and sudden death) by creating risk prediction models to derive individual risk. Results: Manuscript 1: a total of 407 patients referred for cardiac magnetic resonance for suspected ARVC were consecutively enrolled. Of these, 66 (16%) received a definitive diagnosis of ARVC by the determined endpoint: the consensus of an expert panel. Overall, the criteria performed well with a sensitivity and specificity of 92%. However, certain criteria such as the signal averaged electrocardiogram (SAECG) and certain criteria related to family history failed to discriminate. Removing these criteria could reduce false positives without increasing false negatives (net reclassification improvement of 4.3%, P = 0.019). In addition, the electrocardiographic criteria and the presence of arrhythmia had a sensitivity of 100%, which can facilitate screening in some cases by making imaging optional. For manuscripts 2 and 3, a cohort including patients with a definitive diagnosis of ARVC was assembled from databases in 6 countries (Canada, United States, Netherlands, Sweden, Norway, Switzerland). Manuscript 2: a total of 528 patients with no previous history of sustained ventricular arrhythmias were included to develop a risk prediction model. Of these, 146 (27.7%) had an arrhythmic event during a median follow-up of 4.8 years. Of the eight predictors initially identified (younger age at diagnosis, male sex, recent cardiac syncope, the number of leads with T wave inversions on the ECG, burden of extrasystoles in 24 hours, non-sustained ventricular tachycardia and left and right ventricular ejection fraction), seven were retained in the model, excluding only left ventricular ejection fraction. The model adequately distinguished between patients with and without an arrhythmic event (C-index of 0.77) with minimal optimism (calibration slope of 0.93). Using this prediction model would reduce the use of defibrillators by 20% compared with the most commonly used consensus based on a risk factor approach. Manuscript 3: a cohort including both patients with and without a prior history of ventricular arrhythmia of 864 patients was assembled. During a follow-up of 5.75 years, 93 patients had an LTVA as defined above. Of the 8 risk factors cited above, only 4 were retained in the model: younger age at diagnosis, male sex, burden of extrasystoles in 24 hours and number of leads with T-wave inversions. Importantly, previous events are not predictive of these subsequent life-threatening arrhythmias. The model adequately distinguished between patients with and without an event (C-index of 0.74) with minimal optimism (calibration slope of 0.95). Conclusion: Although the current diagnostic criteria for ARVC perform adequately, they can be simplified and improved by removing underperforming individual criteria. The absence of any ECG criteria and ventricular arrhythmias may rule out ARVC, which may simplify screening. In patients with ARVC, risk prediction and patient selection for a defibrillator can be facilitated by two complementary risk prediction models for sustained arrhythmic events or more specifically for LTVA. These tools are particularly useful in a shared decision-making approach for implantable cardioverter defibrillator implantation.
9

Recherche économique en santé cardiovasculaire

Guertin, Jason Robert 02 1900 (has links)
Les nouvelles technologies médicales contribuent aux dépenses en santé qui ne cessent de croître, alors que les budgets se trouvent limités. L’évaluation économique des technologies devraient permettre d’identifier quelles sont celles qui sont les plus rentables. Malgré cela, plusieurs technologies dont le rapport coût-efficacité reste plutôt limite ou défavorable sont utilisées en médecine moderne et remboursées par notre système public de santé. Ce mémoire se concentre sur deux technologies en santé cardiovasculaire dont le rapport coût-efficacité est plutôt limite mais qui sont fréquemment utilisées au Canada; les tuteurs médicamentés ou pharmaco-actifs et les défibrillateurs cardiaques implantables (DCI). Nous avons fait une évaluation contingente de ces technologies dans le but d’examiner si ce type d’évaluation économique complémentaire pouvait procurer un point de vue nouveau sur la valeur économique et sociétaire des ces technologies. Les résultats de ces deux évaluations indiquent que les patients accordent une grande importance aux bénéfices que procurent ces deux technologies. Nos résultats soutiennent les politiques de santé actuelles de rembourser de façon libérale ces deux technologies. / Technological innovations have greatly contributed to the rising costs in healthcare, while budgets have remained limited. Economic evaluations of technologies should identify which technologies are cost-effective. However, several technologies used in modern medicine are either borderline cost-effective or even not cost-effective according to many studies. This thesis focuses on two technologies in cardiovascular medicine which are considered borderline cost-effective; drug-eluting stents and implantable cardioverter defibrillators. We conducted a contingent valuation of these technologies in hopes of determining if this alternative type of economic evaluation could give a novel point of view on the economic and societal value of these technologies. Results indicated that patients greatly valued benefits provided by these two technologies. Our result support our public healthcare system policies’ of liberal reimbursement of these two technologies.
10

Recherche économique en santé cardiovasculaire

Guertin, Jason R. 02 1900 (has links)
Les nouvelles technologies médicales contribuent aux dépenses en santé qui ne cessent de croître, alors que les budgets se trouvent limités. L’évaluation économique des technologies devraient permettre d’identifier quelles sont celles qui sont les plus rentables. Malgré cela, plusieurs technologies dont le rapport coût-efficacité reste plutôt limite ou défavorable sont utilisées en médecine moderne et remboursées par notre système public de santé. Ce mémoire se concentre sur deux technologies en santé cardiovasculaire dont le rapport coût-efficacité est plutôt limite mais qui sont fréquemment utilisées au Canada; les tuteurs médicamentés ou pharmaco-actifs et les défibrillateurs cardiaques implantables (DCI). Nous avons fait une évaluation contingente de ces technologies dans le but d’examiner si ce type d’évaluation économique complémentaire pouvait procurer un point de vue nouveau sur la valeur économique et sociétaire des ces technologies. Les résultats de ces deux évaluations indiquent que les patients accordent une grande importance aux bénéfices que procurent ces deux technologies. Nos résultats soutiennent les politiques de santé actuelles de rembourser de façon libérale ces deux technologies. / Technological innovations have greatly contributed to the rising costs in healthcare, while budgets have remained limited. Economic evaluations of technologies should identify which technologies are cost-effective. However, several technologies used in modern medicine are either borderline cost-effective or even not cost-effective according to many studies. This thesis focuses on two technologies in cardiovascular medicine which are considered borderline cost-effective; drug-eluting stents and implantable cardioverter defibrillators. We conducted a contingent valuation of these technologies in hopes of determining if this alternative type of economic evaluation could give a novel point of view on the economic and societal value of these technologies. Results indicated that patients greatly valued benefits provided by these two technologies. Our result support our public healthcare system policies’ of liberal reimbursement of these two technologies.