1

LIMITEUR SUPRACONDUCTEUR DE COURANT CONTINU

Cointe, Yannick 13 December 2007 (has links) (PDF)
Dans le cadre de la libéralisation du marché de l'énergie électrique, les réseaux DC offrent de nombreux avantages par rapport aux réseaux alternatifs, mais leurs protections nécessitent l'utilisation de nouveaux appareils. Les limiteurs supraconducteurs de courant permettent, par le dépassement d'un courant critique, de limiter le courant de défaut à une valeur prédéfinie, inférieure à la valeur théorique du court-circuit. Les conducteurs déposés offrent d'excellentes perspectives pour ces applications. Nous avons ainsi travaillé sur la mise en oeuvre de ces matériaux et réalisé un banc de mesures. Des essais en limitation de courant ont été réalisés afin d'étudier l'homogénéité des transitions pour différents paramètres de court-circuit. Un point important est la mesure de température par des sondes déposées directement sur le ruban, donnant des résultats conformes aux modèles théoriques. Nos essais ont confirmé l'amélioration des transitions pour les fonctionnements proches de la température critique. Nos résultats permettent de mieux comprendre les mécanismes de la limitation de courant par des conducteurs déposés.
2

Conception et caractérisation de microréacteurs photocatalytiques / Design and characterization of a photocatalytic microreactor

Charles, Guillaume 25 February 2011 (has links)
L'objectif général du travail de recherche était l'amélioration de la compréhension de la réaction de dégradation photocatalytique de l’acide salicylique choisi comme polluant modèle. Un réacteur ouvert ayant un canal parallélépipédique, de largeur et de profondeur de l'ordre du millimètre, imprégné de catalyseur TiO₂ , a permis de caractériser la dégradation de l’acide salicylique en fonction des dimensions du canal, du débit, de la concentration en polluant et de l’intensité d'irradiation UV. La fraction dégradée d’acide salicylique diminue avec le débit, la concentration d’entrée et augmente avec l’intensité d’irradiation UV. Pour un temps de passage donné, la réduction de la profondeur et la largeur du microcanal, améliore l’efficacité de la dégradation. En effet, d'une manière générale, la vitesse de la réaction de dégradation est proportionnelle à la surface catalytique sur le volume réactionnel. Le rapport de la surface imprégnée sur le volume du microcanal est augmenté par la miniaturisation du canal ce qui entraine une meilleure dégradation. Un modèle basé sur le modèle de Langmuir-Hinshelwood et tenant compte du transfert de matière permet de rendre compte des résultats expérimentaux. Ce modèle met en évidence que la limitation de la réaction de dégradation par le transfert de matière est plus importante aux plus faibles débits (< 10 ml/h) et quand le canal devient plus profond. La simulation prédit des taux de conversion de l’ordre de 90 %, soit en agissant sur la géométrie (réacteur multicanaux, longueur totale des canaux de l’ordre du mètre), soit sur le procédé (réacteur à recyclage fermé) / The overall objective of the research work was to improve the understanding of the photocatalytic reaction of salicylic acid degradation chosen as model pollutant. An open reactor having a parallelepiped channel, of width and depth near millimetre size, coated with TiO₂ catalyst, was used to characterize the salicylic acid degradation in function of channel dimensions, flow rates, inlet pollutant concentrations and UV irradiation intensities. The degraded fraction of salicylic acid decreases with the flow rate, inlet concentration while it increases with UV irradiation intensity. For a given residence time, the reduction of the microchannel depth and width improve the degradation efficiency. Indeed, the reaction rate of degradation generally increases with the ratio of catalyst area on reaction volume. The ratio of coated area on microchannel volume is increased by miniaturization of the channel which leads to a larger degradation. A model based on the Langmuir-Hinshelwood approach which takes into account the mass-transfer account very well for the experimental results. This model highlights that reaction limitation by mass-transfer is larger at the lowest flows (< 10 mL/h) and when the channel becomes deeper. The simulation allows us to predict that conversion ratio of about 90%, can be reach by both acting on the geometry (multichannel reactor, total length of channels of the order of meter) or on the process (batch recirculation reactor)
3

Toward an energy harvester for leadless pacemakers / Vers un récupérateur d'énergie pour stimulateur intracardiaque

Deterre, Martin 09 July 2013 (has links)
Ce travail consiste à développer un système convertissant une partie de l’énergie mécanique du cœur en électricité pour alimenter les stimulateurs cardiaques de nouvelle génération, implants sans sonde ni batteries implantés directement dans la cavité cardiaque. Après études de différentes sources d’énergies et concept associés, l’option liée à la pression sanguine, appliquant sur une partie souple du boîtier de l’implant des efforts transmis à un transducteur interne les convertissant en électricité, s’est révélée la plus prometteuse. Cette solution présente les avantages principaux suivants par rapport aux systèmes inertiels usuels : grande densité de puissance, adaptabilité au rythme cardiaque et potentiel de miniaturisation. Un boîtier ultra-souple électro-déposé de 10 µm d’épaisseur en forme de soufflet a été modélisé, fabriqué et caractérisé, validant ainsi le concept de récupérateur proposé. Un transducteur électrostatique novateur (3D multicouche à peignes interdigités et à chevauchement hors-plan), étudié par des modélisations analytiques et numériques, est en cours de fabrication. Selon l’électronique associée, ce transducteur promet une grande densité d’énergie extraite. Un transducteur piézoélectrique micro-usiné en forme de spirale et à électrodes micro-structurées, est également présenté. Les défis spécifiques des spirales dontla flexibilité permet d’augmenter l’énergie mécanique d’entrée sont étudiés notamment par simulation numériques, et des prototypes ont été micro-fabriqués et caractérisés. Au final, une énergie de 3 µJ/cm3/cycle est obtenue et de nombreuses perspectives d’amélioration permettent d’envisager une puissance au moins 10 fois supérieure. / This work consists in the development and design of an energy harvesting device to supply power to the new generation pacemakers, miniaturized leadless implants without battery placed directly in heart chambers. After analyzing different mechanical energy sources in the cardiac environment and associated energy harvesting mechanisms, a concept based on regular blood pressure variation stood out: an implant with a flexible packaging that transmits blood forces to an internal transducer. Advantages compared to traditional inertial scavengers are mainly: greater power density, adaptability to heartbeat frequency changes and miniaturization potential. Ultra-flexible 10-µm thin metal bellows have been designed, fabricated and tested. These prototypes acting as implant packaging that deforms under blood pressure actuation have validated the proposed harvesting concept. A new type of electrostatic transducer (3D multi-layer out-of-plane overlap structure with interdigitated combs) has been introduced and fully analyzed. Promising numerical results and associated fabrication processes are presented. Also, large stroke optimized piezoelectric spiral transducers including their complex electrodes patterns have been studied through a design analysis, numerical simulations, prototype fabrication and experimental testing. Apower density of 3 µJ/cm3/cycle has been experimentally achieved. With further addressed developments, the proposed device should provide enough energy to power autonomously and virtually perpetually the next generation of pacemakers.