• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Controle robusto de dispositivos FACTS para o amortecimento de oscilações em sistemas elétricos de potência / Robust control of FACTS devices to damp oscillations in electric power systems

Rôman Kuiava 23 February 2007 (has links)
Este trabalho apresenta um método sistemático para projeto de controladores suplementares para um tipo de dispositivo FACTS (o modelo TCSC) para o amortecimento de oscilações em sistemas elétricos de potência. Adota-se uma metodologia previamente desenvolvida para projeto de apenas controladores de tipo PSS. Tal metodologia é fundamentada na teoria de controle robusto e estruturada na forma de desigualdades matriciais lineares (LMIs). A modelagem politópica é utilizada para tratar a robustez dos controladores frente às variações no ponto de operação do sistema. O fator de amortecimento mínimo para os modos de resposta do sistema em malha fechada é especificado como índice de desempenho mínimo a ser satisfeito na fase de projeto. Os controladores propostos possuem uma estrutura de realimentação dinâmica de saída e utilizam sinais medidos localmente como entrada de controle. O projeto dos controladores propostos é realizado de duas maneiras diferentes: (i) projeto simultâneo e coordenado de controladores de tipo PSS e controlador suplementar de dispositivo TCSC para amortecimento tanto de modos locais, quanto de modos inter-área e; (ii) projeto de controlador suplementar para apenas um dispositivo TCSC operando no sistema com a finalidade de amortecer modos inter-área pouco amortecidos e instáveis. No primeiro caso, a descentralização dos controladores é garantida através da imposição de uma estrutura bloco-diagonal para as variáveis matriciais presentes na formulação do problema de controle. No segundo caso, este trabalho propõe uma extensão da metodologia de projeto utilizada no caso anterior ao combiná-la com uma técnica de redução da ordem de modelo do controlador. A análise de desempenho dos controladores em malha fechada é realizada através de análise modal e simulações não-lineares em dois sistemas testes. O primeiro deles é constituído por 10 barras e 4 geradores e o segundo sistema teste apresenta 40 barras e 10 geradores. / This work proposes a systematic method for the design of supplementary controllers for a type of FACTS device (the TCSC device model) to damp oscillations in electric power systems. It is adopted a technique previously presented to design only PSS-type damping controllers. The method is based on a robust control technique structured in the form of linear matrix inequalities (LMIs). The polytopic model is used to guarantee the robustness of the controllers with respect to the variations in the operating points of the system. The minimum damping ratio is used in the design stage as performance index for the closed loop system. The proposed controllers are based on dynamic output feedback and uses only local measurements as input signals. The design of the proposed controllers is realized in two different cases: (i) a simultaneous coordinated design of PSS-type controllers and TCSC supplementary controller to damp both local and interarea oscillations and; (ii) design of a supplementary controller for a FACTS device only to damp poorly damped and unstable inter-area oscillations. In the first case, a decentralized structure of the controllers is guaranteed by adoption of a block-diagonal strutucture to the matricial variables of the control problem. In the second case, this work proposes a extension of the previously methodology by combining it with a model order reduction technique. Performance analyses of the closed loop system were carried out by means of modal analysis and nonlinear simulations in two test systems. The first one is constituted by 10 buses and 4 generators and the other test system is constituted by 40 buses and 10 generators.
2

Controle robusto de dispositivos FACTS para o amortecimento de oscilações em sistemas elétricos de potência / Robust control of FACTS devices to damp oscillations in electric power systems

Kuiava, Rôman 23 February 2007 (has links)
Este trabalho apresenta um método sistemático para projeto de controladores suplementares para um tipo de dispositivo FACTS (o modelo TCSC) para o amortecimento de oscilações em sistemas elétricos de potência. Adota-se uma metodologia previamente desenvolvida para projeto de apenas controladores de tipo PSS. Tal metodologia é fundamentada na teoria de controle robusto e estruturada na forma de desigualdades matriciais lineares (LMIs). A modelagem politópica é utilizada para tratar a robustez dos controladores frente às variações no ponto de operação do sistema. O fator de amortecimento mínimo para os modos de resposta do sistema em malha fechada é especificado como índice de desempenho mínimo a ser satisfeito na fase de projeto. Os controladores propostos possuem uma estrutura de realimentação dinâmica de saída e utilizam sinais medidos localmente como entrada de controle. O projeto dos controladores propostos é realizado de duas maneiras diferentes: (i) projeto simultâneo e coordenado de controladores de tipo PSS e controlador suplementar de dispositivo TCSC para amortecimento tanto de modos locais, quanto de modos inter-área e; (ii) projeto de controlador suplementar para apenas um dispositivo TCSC operando no sistema com a finalidade de amortecer modos inter-área pouco amortecidos e instáveis. No primeiro caso, a descentralização dos controladores é garantida através da imposição de uma estrutura bloco-diagonal para as variáveis matriciais presentes na formulação do problema de controle. No segundo caso, este trabalho propõe uma extensão da metodologia de projeto utilizada no caso anterior ao combiná-la com uma técnica de redução da ordem de modelo do controlador. A análise de desempenho dos controladores em malha fechada é realizada através de análise modal e simulações não-lineares em dois sistemas testes. O primeiro deles é constituído por 10 barras e 4 geradores e o segundo sistema teste apresenta 40 barras e 10 geradores. / This work proposes a systematic method for the design of supplementary controllers for a type of FACTS device (the TCSC device model) to damp oscillations in electric power systems. It is adopted a technique previously presented to design only PSS-type damping controllers. The method is based on a robust control technique structured in the form of linear matrix inequalities (LMIs). The polytopic model is used to guarantee the robustness of the controllers with respect to the variations in the operating points of the system. The minimum damping ratio is used in the design stage as performance index for the closed loop system. The proposed controllers are based on dynamic output feedback and uses only local measurements as input signals. The design of the proposed controllers is realized in two different cases: (i) a simultaneous coordinated design of PSS-type controllers and TCSC supplementary controller to damp both local and interarea oscillations and; (ii) design of a supplementary controller for a FACTS device only to damp poorly damped and unstable inter-area oscillations. In the first case, a decentralized structure of the controllers is guaranteed by adoption of a block-diagonal strutucture to the matricial variables of the control problem. In the second case, this work proposes a extension of the previously methodology by combining it with a model order reduction technique. Performance analyses of the closed loop system were carried out by means of modal analysis and nonlinear simulations in two test systems. The first one is constituted by 10 buses and 4 generators and the other test system is constituted by 40 buses and 10 generators.
3

Design Of Robust Power System Damping Controllers For Interconnected Power Systems

Ajit Kumar, * 12 1900 (has links) (PDF)
Small signal oscillation has been always a major concern in the operation of power systems. In a generator, the electromechanical coupling between the rotor and the rest of the system causes it to behave in a manner similar to a spring mass damper system, which exhibits an oscillatory behaviour around the equilibrium state, following any disturbance, such as sudden change in loads, fluctuations in the output of turbine and faults etc. The use of fast acting high gain AVRs and evolution of large interconnected power systems with transfer of bulk power across weak transmission links have further aggravated the problem of these low frequency oscillations. Small oscillations in the range of about 0.1Hz to 3.5Hz can persist for long periods, limiting the power transfer capability of the transmission lines. Power System Stabilizers (PSS’s) were developed as auxiliary controllers on the generators excitation system to produce additional damping by modulating the generator excitation voltage. Designing effective PSS for all operating conditions specially in large interconnected power systems still remains a difficult and challenging task. The conventionally designed Power System Stabilizer (CPSS) is the most cost-effective electromechanical damping controller till date. However, continual changes in the operating condition and network parameters in large systems result in corresponding large changes in system dynamics. This constantly changing nature of power system makes the design of CPSS a difficult task. The design and tuning of PSS for robust operation is a laborious process. The existing PSS design techniques require considerable expertise, the complete system information and extensive eigenvalue calculations which increases the computational burden as the system size increases. This thesis proposes a method for designing robust power system damping controllers that ensures a minimum robustness under model uncertainties. The minimum performance required for the PSS is set a priori and accomplished over a range of operating conditions. A generalized robust controller design methodology has been first implemented on a Single Machine Infinite Bus (SMIB) power system model. The robust controller places the closed loop rotor modes of the system to the desire location while keeping the electrical modes intact. Unlike conventional lead/lag PSS design, the proposed PSS design is based on pole assignment technique which takes into account of various model uncertainties. For the proposed stabilizer design in a multi-machine systems a new decentralized method has been used which requires system data only upto secondary bus of the unit transformer in a generating station. The proposed robust controller design based on modified Nevanlinna-Pick theory has been designed and tested extensively on SMIB and multi-machine systems to establish the efficacy of the controller in damping small signal oscillations. The thesis is organized in four chapters as follows. The first chapter discusses the basic concepts related to the rotor angle stability in power system. The conventional and other methods of countering this instability by power system stabilizers have been described. The relative merits of the various stabilization techniques have been discussed. The scope of present work, i.e design of decentralized robust power system controllers has been defined. In second chapter a modified robust power system stabilizer for SMIB system is developed. It has been shown that under specific conditions the modified Nevanlinna-Pick theory can also be applied for designing damping controllers in system with lightly damped rotor modes. Third chapter proposes a decentralized approach based on modified Nevanlinna-Pick theory for designing a power system stabilizer for interconnected power systems. The performance of the controller which is not based on external system information has been investigated on three widely used multi-machine test systems to established its efficacy in damping out low frequency oscillations. The fourth chapter gives a brief summary of the work done and also includes a section on the scope of future work relating to design of power system stabilizers.
4

Projeto de controladores para o amortecimento de oscilações em sistemas elétricos com geração distribuída / Design of controllers to damp oscillations in electrical systems with distributed generation

Kuiava, Roman 04 March 2010 (has links)
Essa pesquisa se propõe a investigar o uso de Inclusões Diferenciais Lineares Limitadas por Norma (IDLNs) para projeto de controladores de amortecimento de tipo PSS (Power System Stabilizer) para sistemas elétricos com a presença de geração distribuída. Uma vez definida de maneira adequada, uma IDLN pode ser capaz de englobar um conjunto de trajetórias do modelo não-linear do sistema em estudo. Assim, é possível garantir certas propriedades (estabilidade assintótica, por exemplo) para as trajetórias da IDLN e, consequentemente, as mesmas propriedades terão validade para as trajetórias do modelo não-linear. Inicialmente propõe-se um procedimento para cálculo dos parâmetros do modelo de IDLN proposto de forma que ela seja capaz de agregar um conjunto de dinâmicas de interesse do sistema. Tal procedimento divide-se, basicamente, em duas etapas. Na primeira etapa, o objetivo é englobar um conjunto de trajetórias do modelo não-linear do sistema numa Inclusão Diferencial Linear Politópica (IDLP). Já na segunda etapa, os parâmetros da IDLN são calculados a partir da solução um problema na forma de LMIs (Linear Matrix Inequalities) que utiliza informações da IDLP obtida anteriormente. Em seguida, essa pesquisa propõe um procedimento sistemático na forma de LMIs para projeto de controladores de amortecimento de tipo PSS para sistemas de geração distribuída usando-se os modelos de IDLNs propostos. Restrições na forma de desigualdades matriciais são incluídas ao problema de controle para garantir um desempenho mínimo a ser atingido pelo controlador. Como resultado, a formulação do problema de controle é descrita por um conjunto de BMIs (Bilinear Matrix Inequalities). Entretanto, através de um procedimento de separação pode-se tratar o problema em duas etapas, ambas envolvendo a solução de um conjunto de LMIs. Uma planta de co-geração instalada numa rede de distribuição composta por um alimentador e 6 barras é utilizada como sistema teste. / This work proposes an investigation about the use of Norm-bounded Linear Differential Inclusions (NLDIs) for the design of PSS-type damping controllers for electrical systems with the presence of distributed generation. When the NLDI is properly defined, it is possible to guarantee certain properties (for example, asymptotic stability) to the trajectories of the NLDI and, consequently, the trajectories of the nonlinear model have these same properties. Initially, this research proposes a procedure to calculate the NLDI parameters in such way it can be capable to aggregate a set of dynamics of interest. Such procedure is constituted by two steps. In the first step, the objective is to aggregate some trajectories of the nonlinear model to a Politopic Linear Differential Inclusion (PLDI). In the second step, the NLDI parameters are calculated by solving a problem in the form of LMIs (Linear Matrix Inequalities) that uses the IDLP previously obtained. After that, this research proposes a systematic method based on LMIs for the design of PSS-type damping controllers for distributed generation systems. Such method uses the proposed NLDI models. Constraints in the form of LMIs are included to the control problem formulation in order to guarantee a desirable performance to the controller. As a result, the control problem formulation is structured by a set of BMIs (Bilinear Matrix Inequalities). However, it is possible to deal with such problem in two steps,both involving the solution of a set of LMIs. A cogeneration plant added to a distribution network constituted by a feeder and six buses is adopted as test system.
5

Procedimento de projeto de controladores robustos para o amortecimento de oscilações eletromecânicas em sistemas de potência. / Robust controller design procedure for electromechanical oscillation damping in power systems.

Ramos, Rodrigo Andrade 16 December 2002 (has links)
Este trabalho propõe uma nova metodologia de projeto de controladores para o amortecimento de oscilações eletromecânicas de baixa freqüência em sistemas de potência. Considerando a necessidade de se aumentar a robustez dos estabilizadores clássicos frente a variações nas condições de operação, este estudo analisou uma série de requisitos práticos a serem atendidos pelos novos controladores de amortecimento e desenvolveu a metodologia proposta, de tal forma que os controladores projetados pudessem satisfazer a todos os requisitos analisados. Foram tratadas questões relativas à estrutura de controle (realimentação dinâmica descentralizada de saída), à robustez de estabilidade e desempenho (através da modelagem politópica e dos critérios de posicionamento regional de pólos) e da não atuação dos controladores em regime permanente (com a inclusão de filtros washout na modelagem). A principal vantagem desta metodologia proposta é a possibilidade de se garantir formalmente um desempenho robusto dos controladores, dentro de uma região pré-especificada de pontos de operação. Os resultados, obtidos através de simulações não lineares da resposta (para uma série de perturbações) dos sistemas escolhidos para teste, em diversas condições de operação, mostram que os controladores obtidos com a aplicação desta metodologia são capazes de manter seu desempenho frente às variações consideradas. Além disso, a obtenção de resultados satisfatórios com a aplicação desta metodologia a um sistema com 45 variáveis de estado indica boas perspectivas para a utilização conjunta da mesma com técnicas de redução do modelo de estados, para o projeto de controladores de amortecimento em sistemas reais de grande porte. / This research proposes a new methodology for the design of controllers to damp low frequency electromechanical oscillations in power systems. Considering the need to improve the robustness of the classical stabilizers, with respect to variations in the operating conditions, this study has analyzed a series of practical requirements to be met by the new damping controllers and developed the proposed methodology, so the designed controllers could satisfy all the analyzed equirements. Questions regarding the controller structure (decentralized dynamic output feedback), the robustness of stability and performance (through the polytopic modelling and the regional pole placement criteria) and the non influence of the controllers over the steady state behavior of the system (with the inclusion of washout filters in the model) were treated. The main advantage of the proposed methodology is the possibility to ensure, formally, the performance robustness of the controllers, within a previously specified region of operating points. The results, obtained through the eigenanalysis of the closed loop system and the nonlinear simulations of the system responses to a series of disturbances, in various operating conditions, show that the controllers provided by this new methodology are capable of maintaining their performance, despite the considered variations. Moreover, the satisfactory results obtained with the application of this methodology to a system with 45 state variables indicates good perspectives for the joint utilization of the methodology and model order reduction techniques, for the design of damping controllers for real-sized systems.
6

Projeto de controladores de amortecimento para sistemas elétricos de potência / Design of damping controllers for electric power systems

Oliveira, Ricardo Vasques de 21 February 2006 (has links)
O presente trabalho propõe, como inovação, o limite superior para a energia da saída do sistema em malha fechada como índice de desempenho a ser usado no projeto de controladores robustos para amortecer oscilações eletromecânicas de baixa freqüência em sistemas de potência. A saída do sistema em malha fechada é especificada de forma que a energia da saída corresponda ao valor acumulado do desvio da energia cinética do sistema. O índice de desempenho proposto mostrou-se adequado ao problema de oscilações eletromecânicas. Tal índice de desempenho é utilizado na formulação de uma metodologia sistemática de projeto. O problema de controle é estruturado na forma de desigualdades matriciais lineares, permitindo a obtenção de uma solução numérica para o problema. A obtenção da solução do problema de controle proposto (energia da saída como índice de desempenho) exige menos dispêndio computacional, quando comparado com o tradicional fator de amortecimento mínimo na forma de posicionamento regional de pólos. Tal característica pode ser significativa para o tempo computacional requerido pelo projeto de controladores envolvendo modelos sistemas de potência de ordem elevada. O projeto de controladores de amortecimento robustos, baseados em modelos multimáquinas que dispensem a hipótese de existência de um barramento infinito, constitui a segunda parte da pesquisa proposta. Os problemas inerentes à hipótese do barramento infinito são resolvidos pelo uso de duas abordagens que não adotam tal hipótese. A primeira abordagem adotada refere-se ao uso de um modelo multimáquinas com o ângulo de uma das máquinas do sistema como referência angular. A segunda alternativa proposta é a incorporação do sistema primário de controle de velocidade no modelo multimáquinas referente à primeira alternativa. Além de resolver o problema referente ao uso do barramento infinito, o presente trabalho também propõe análises da influência da hipótese de tal barramento no projeto de controladores de amortecimento. A influência da hipótese do barramento infinito no projeto dos controladores é delineada por meio dos fundamentos expostos e dos resultados obtidos com as diferentes alternativas utilizadas / The present work proposes, as innovation, an upper bound for the output energy of the closed loop system to be used as a performance index in the design of robust controllers to damp low-frequency electromechanical oscillations in electric power systems. The output of the closed loop system is specified so that the output energy corresponds to the accumulated value of the kinetic energy deviation of the closed loop system. The performance index used in the procedure has shown to be suitable to the oscillation problem. The proposed performance index is used in the formulation of a systematic design methodology. The control problem is structured in the form of linear matrix inequalities, allowing a numerical solution to the control problem. The adopted performance index is less costly in terms of computational effort when compared with the traditional minimum damping ratio (performance index usually accepted in power system as small signal stability margin) via regional pole placement in the LMI formulation. This characteristic may be significant to the computational time required for the controller design involving large power system models. The robust damping controller design, based on multimachine models without the infinite-bus assumption, constitutes the second part of this research proposal. The problems inherent to the infinte-bus assumption are solved by means of two approaches which do not use such assumption. The first proposed approach refers to the use of a multimachine model adopting one machine angle of the system as angular reference. The second adopted approach is the incorporation of the primary speed control in the multimachine model regarding to the first approach. Besides solving the problem regarding to the use of infinite-bus assumption, the present work also proposes analyses of such assumption influence in the design of damping controllers. The influence of such assumption, in the design of the controllers, is outlined by means of exposed fundamentals and results obtained with the proposed approaches
7

Projeto de controladores para o amortecimento de oscilações em sistemas elétricos com geração distribuída / Design of controllers to damp oscillations in electrical systems with distributed generation

Roman Kuiava 04 March 2010 (has links)
Essa pesquisa se propõe a investigar o uso de Inclusões Diferenciais Lineares Limitadas por Norma (IDLNs) para projeto de controladores de amortecimento de tipo PSS (Power System Stabilizer) para sistemas elétricos com a presença de geração distribuída. Uma vez definida de maneira adequada, uma IDLN pode ser capaz de englobar um conjunto de trajetórias do modelo não-linear do sistema em estudo. Assim, é possível garantir certas propriedades (estabilidade assintótica, por exemplo) para as trajetórias da IDLN e, consequentemente, as mesmas propriedades terão validade para as trajetórias do modelo não-linear. Inicialmente propõe-se um procedimento para cálculo dos parâmetros do modelo de IDLN proposto de forma que ela seja capaz de agregar um conjunto de dinâmicas de interesse do sistema. Tal procedimento divide-se, basicamente, em duas etapas. Na primeira etapa, o objetivo é englobar um conjunto de trajetórias do modelo não-linear do sistema numa Inclusão Diferencial Linear Politópica (IDLP). Já na segunda etapa, os parâmetros da IDLN são calculados a partir da solução um problema na forma de LMIs (Linear Matrix Inequalities) que utiliza informações da IDLP obtida anteriormente. Em seguida, essa pesquisa propõe um procedimento sistemático na forma de LMIs para projeto de controladores de amortecimento de tipo PSS para sistemas de geração distribuída usando-se os modelos de IDLNs propostos. Restrições na forma de desigualdades matriciais são incluídas ao problema de controle para garantir um desempenho mínimo a ser atingido pelo controlador. Como resultado, a formulação do problema de controle é descrita por um conjunto de BMIs (Bilinear Matrix Inequalities). Entretanto, através de um procedimento de separação pode-se tratar o problema em duas etapas, ambas envolvendo a solução de um conjunto de LMIs. Uma planta de co-geração instalada numa rede de distribuição composta por um alimentador e 6 barras é utilizada como sistema teste. / This work proposes an investigation about the use of Norm-bounded Linear Differential Inclusions (NLDIs) for the design of PSS-type damping controllers for electrical systems with the presence of distributed generation. When the NLDI is properly defined, it is possible to guarantee certain properties (for example, asymptotic stability) to the trajectories of the NLDI and, consequently, the trajectories of the nonlinear model have these same properties. Initially, this research proposes a procedure to calculate the NLDI parameters in such way it can be capable to aggregate a set of dynamics of interest. Such procedure is constituted by two steps. In the first step, the objective is to aggregate some trajectories of the nonlinear model to a Politopic Linear Differential Inclusion (PLDI). In the second step, the NLDI parameters are calculated by solving a problem in the form of LMIs (Linear Matrix Inequalities) that uses the IDLP previously obtained. After that, this research proposes a systematic method based on LMIs for the design of PSS-type damping controllers for distributed generation systems. Such method uses the proposed NLDI models. Constraints in the form of LMIs are included to the control problem formulation in order to guarantee a desirable performance to the controller. As a result, the control problem formulation is structured by a set of BMIs (Bilinear Matrix Inequalities). However, it is possible to deal with such problem in two steps,both involving the solution of a set of LMIs. A cogeneration plant added to a distribution network constituted by a feeder and six buses is adopted as test system.
8

Procedimento de projeto de controladores robustos para o amortecimento de oscilações eletromecânicas em sistemas de potência. / Robust controller design procedure for electromechanical oscillation damping in power systems.

Rodrigo Andrade Ramos 16 December 2002 (has links)
Este trabalho propõe uma nova metodologia de projeto de controladores para o amortecimento de oscilações eletromecânicas de baixa freqüência em sistemas de potência. Considerando a necessidade de se aumentar a robustez dos estabilizadores clássicos frente a variações nas condições de operação, este estudo analisou uma série de requisitos práticos a serem atendidos pelos novos controladores de amortecimento e desenvolveu a metodologia proposta, de tal forma que os controladores projetados pudessem satisfazer a todos os requisitos analisados. Foram tratadas questões relativas à estrutura de controle (realimentação dinâmica descentralizada de saída), à robustez de estabilidade e desempenho (através da modelagem politópica e dos critérios de posicionamento regional de pólos) e da não atuação dos controladores em regime permanente (com a inclusão de filtros washout na modelagem). A principal vantagem desta metodologia proposta é a possibilidade de se garantir formalmente um desempenho robusto dos controladores, dentro de uma região pré-especificada de pontos de operação. Os resultados, obtidos através de simulações não lineares da resposta (para uma série de perturbações) dos sistemas escolhidos para teste, em diversas condições de operação, mostram que os controladores obtidos com a aplicação desta metodologia são capazes de manter seu desempenho frente às variações consideradas. Além disso, a obtenção de resultados satisfatórios com a aplicação desta metodologia a um sistema com 45 variáveis de estado indica boas perspectivas para a utilização conjunta da mesma com técnicas de redução do modelo de estados, para o projeto de controladores de amortecimento em sistemas reais de grande porte. / This research proposes a new methodology for the design of controllers to damp low frequency electromechanical oscillations in power systems. Considering the need to improve the robustness of the classical stabilizers, with respect to variations in the operating conditions, this study has analyzed a series of practical requirements to be met by the new damping controllers and developed the proposed methodology, so the designed controllers could satisfy all the analyzed equirements. Questions regarding the controller structure (decentralized dynamic output feedback), the robustness of stability and performance (through the polytopic modelling and the regional pole placement criteria) and the non influence of the controllers over the steady state behavior of the system (with the inclusion of washout filters in the model) were treated. The main advantage of the proposed methodology is the possibility to ensure, formally, the performance robustness of the controllers, within a previously specified region of operating points. The results, obtained through the eigenanalysis of the closed loop system and the nonlinear simulations of the system responses to a series of disturbances, in various operating conditions, show that the controllers provided by this new methodology are capable of maintaining their performance, despite the considered variations. Moreover, the satisfactory results obtained with the application of this methodology to a system with 45 state variables indicates good perspectives for the joint utilization of the methodology and model order reduction techniques, for the design of damping controllers for real-sized systems.
9

Projeto de controladores de amortecimento para sistemas elétricos de potência / Design of damping controllers for electric power systems

Ricardo Vasques de Oliveira 21 February 2006 (has links)
O presente trabalho propõe, como inovação, o limite superior para a energia da saída do sistema em malha fechada como índice de desempenho a ser usado no projeto de controladores robustos para amortecer oscilações eletromecânicas de baixa freqüência em sistemas de potência. A saída do sistema em malha fechada é especificada de forma que a energia da saída corresponda ao valor acumulado do desvio da energia cinética do sistema. O índice de desempenho proposto mostrou-se adequado ao problema de oscilações eletromecânicas. Tal índice de desempenho é utilizado na formulação de uma metodologia sistemática de projeto. O problema de controle é estruturado na forma de desigualdades matriciais lineares, permitindo a obtenção de uma solução numérica para o problema. A obtenção da solução do problema de controle proposto (energia da saída como índice de desempenho) exige menos dispêndio computacional, quando comparado com o tradicional fator de amortecimento mínimo na forma de posicionamento regional de pólos. Tal característica pode ser significativa para o tempo computacional requerido pelo projeto de controladores envolvendo modelos sistemas de potência de ordem elevada. O projeto de controladores de amortecimento robustos, baseados em modelos multimáquinas que dispensem a hipótese de existência de um barramento infinito, constitui a segunda parte da pesquisa proposta. Os problemas inerentes à hipótese do barramento infinito são resolvidos pelo uso de duas abordagens que não adotam tal hipótese. A primeira abordagem adotada refere-se ao uso de um modelo multimáquinas com o ângulo de uma das máquinas do sistema como referência angular. A segunda alternativa proposta é a incorporação do sistema primário de controle de velocidade no modelo multimáquinas referente à primeira alternativa. Além de resolver o problema referente ao uso do barramento infinito, o presente trabalho também propõe análises da influência da hipótese de tal barramento no projeto de controladores de amortecimento. A influência da hipótese do barramento infinito no projeto dos controladores é delineada por meio dos fundamentos expostos e dos resultados obtidos com as diferentes alternativas utilizadas / The present work proposes, as innovation, an upper bound for the output energy of the closed loop system to be used as a performance index in the design of robust controllers to damp low-frequency electromechanical oscillations in electric power systems. The output of the closed loop system is specified so that the output energy corresponds to the accumulated value of the kinetic energy deviation of the closed loop system. The performance index used in the procedure has shown to be suitable to the oscillation problem. The proposed performance index is used in the formulation of a systematic design methodology. The control problem is structured in the form of linear matrix inequalities, allowing a numerical solution to the control problem. The adopted performance index is less costly in terms of computational effort when compared with the traditional minimum damping ratio (performance index usually accepted in power system as small signal stability margin) via regional pole placement in the LMI formulation. This characteristic may be significant to the computational time required for the controller design involving large power system models. The robust damping controller design, based on multimachine models without the infinite-bus assumption, constitutes the second part of this research proposal. The problems inherent to the infinte-bus assumption are solved by means of two approaches which do not use such assumption. The first proposed approach refers to the use of a multimachine model adopting one machine angle of the system as angular reference. The second adopted approach is the incorporation of the primary speed control in the multimachine model regarding to the first approach. Besides solving the problem regarding to the use of infinite-bus assumption, the present work also proposes analyses of such assumption influence in the design of damping controllers. The influence of such assumption, in the design of the controllers, is outlined by means of exposed fundamentals and results obtained with the proposed approaches

Page generated in 0.1022 seconds