• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 11
  • 2
  • Tagged with
  • 60
  • 60
  • 31
  • 28
  • 24
  • 24
  • 24
  • 24
  • 17
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Retrospektive Bewegungskorrektur zur hochaufgelösten Darstellung der menschlichen Lunge mittels Magnetresonanztomographie / Retrospective Motion Correction for High Resolution Magnetic Resonance Imaging of the Human Lung

Weick, Stefan January 2015 (has links) (PDF)
Ziel dieser Arbeit war es, das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung mittels der MRT darzustellen. Um trotz der niedrigen Protonendichte der Lunge und der geforderten hohen Auflösung ausreichend Signal für eine verlässliche Diagnostik zu erhalten, sind Aufnahmezeiten von einigen Minuten nötig. Um die Untersuchung für den Patienten angenehmer zu gestalten oder auf Grund der eingeschränkten Fähigkeit eines Atemstopps überhaupt erst zu ermöglichen, war eine Anforderung, die Aufnahmen in freier Atmung durchzuführen. Dadurch entstehen allerdings Bewegungsartefakte, die die Diagnostik stark beeinträchtigen und daher möglichst vermieden werden müssen. Für eine Bewegungskompensation der Daten muss die auftretende Atembewegung detektiert werden. Die Bewegungsdetektion kann durch externe Messgeräte (Atemgurt oder Spirometer) oder durch eine zusätzliche Anregungen erfolgen (konventionelle Navigatoren) erfolgen. Nachteile dieser Methoden bestehen darin, dass die Bewegung während der Atmung nicht direkt verfolgt wird, dass elektronische Messgeräte in die Nähe des Tomographen gebracht werden und das die Patienten zusätzlich vorbereitet und eingeschränkt werden. Des Weiteren erfordert eine zusätzliche Anregung extra Messzeit und kann unter Umständen die Magnetisierung auf unterwünschte Weise beeinflussen. Um die angesprochenen Schwierigkeiten der Bewegungsdetektion zu umgehen, wurden in dieser Arbeit innerhalb einer Anregung einer 3d FLASH-Sequenz sowohl Bilddaten- als auch Navigatordaten aufgenommen. Als Navigator diente dabei das nach der Rephasierung aller bildgebenden Gradienten entstehende Signal (DC Signal). Das DC Signal entspricht dabei der Summe aller Signale, die mit einem bestimmten Spulenelement detektiert werden können. Bewegt sich beispielsweise die Leber bedingt durch die Atmung in den Sensitivitätsbereich eines Spulenelementes, wird ein stärkeres DC Signal detektiert werden. Je nach Positionierung auf dem Körper kann so die Atembewegung mit einzelnen räumlich lokalisierten Spulenelementen nachverfolgt werden. Am DC Signalverlauf des für die Bewegungskorrektur ausgewählten Spulenelementes sind dann periodische Signalschwankungen zu erkennen. Zusätzlich können aus dem Verlauf Expirations- von Inspirationszuständen unterschieden werden, da sich Endexpirationszustände im Regelfall durch eine längere Verweildauer auszeichnen. Grundsätzlich kann das DC Signal vor oder nach der eigentlichen Datenaufnahme innerhalb einer Anregung aufgenommen werden. Auf Grund der kurzen Relaxationszeit T∗2 des Lungengewebes fällt das Signal nach der RF Anregung sehr schnell ab. Um möglichst viel Signal zu erhalten sollten, wie in dieser Arbeit gezeigt wurde, innerhalb einer Anregung zuerst die Bilddaten und danach die Navigatordaten aufgenommen werden. Dieser Ansatz führt zu einer Verkürzung der Echozeit TE um 0.3 ms und damit zu einem SNR Gewinn von etwa 20 %. Gleichzeitig ist das verbleibende Signal nach der Datenakquisition und Rephasierung der bildgebenden Gradienten noch ausreichend um die Atembewegung zu erfassen und somit eine Bewegungskorrektur der Daten (Navigation) zu ermöglichen. Um eine retrospektive Bewegungskorrektur durchführen zu können, müssen Akzeptanzbedingungen (Schwellenwerte) für die Datenauswahl festgelegt werden. Bei der Wahl des Schwellenwertes ist darauf zu achten, dass weder zu wenige noch zu viele Daten akzeptiert werden. Akzeptiert man sehr wenige Daten, zeichnen sich die Rekonstruktionen durch einen scharfen Übergang zwischen Lunge und Diaphragma aus, da man sehr wenig Bewegung in den Rekonstruktionen erlaubt. Gleichzeitig erhöht sich allerdings das Risiko, dass nach der Navigation Linien fehlen. Dies führt zu Einfaltungsartefakten, die in Form von gestörten Bildintensitäten in den Rekonstruktionen zu sehen sind und die diagnostische Aussagekraft einschränken. Um Einfaltungsartefakte zu vermeiden sollte der Schwellenwert so gewählt werden, dass nach der Datenauswahl keine Linien fehlen. Aus dieser Anforderung lässt sich ein maximaler Schwellenwert ableiten. Akzeptiert man dagegen sehr viele Daten, zeichnen sich die Rekonstruktionen durch erhöhtes Signal und das vermehrte Auftreten von Bewegungsartefakten aus. In diesem Fall müsste der Arzt entscheiden, ob Bewegungsartefakte die Diagnostik zu stark beeinflussen. Wählt man den Schwellenwert so, dass weder Linien fehlen noch zu viel Bewegung erlaubt wird, erhält man Rekonstruktionen die sich durch einen scharfen Diaphragmaübergang auszeichnen und in denen noch kleinste Gefäße auch in der Nähe des Diaphragmas deutlich zu erkennen sind. Hierfür haben sich Schwellenwerte, die zu einer Datenakzeptanz von ca. 40 % führen als günstig erwiesen. Um Einfaltungsartefakte auf Grund der retrospektiven Datenauswahl zu verhindern, muss das Bildgebungsvolumen mehrfach abgetastet werden. Dadurch wird gewährleistet, dass für die letztendliche Rekonstruktion ausreichend Daten zur Verfügung stehen, wobei mehrfach akzeptierte Daten gemittelt werden. Dies spielt auf Grund der niedrigen Protonendichte der Lunge eine wesentliche Rolle in der Rekonstruktion hochaufgelöster Lungendatensätze. Weiterhin führt das Mitteln von mehrfach akzeptierten Daten zu einer Unterdrückung der sogenannten Ghost Artefakte, was am Beispiel der Herzbewegung in der Arbeit gezeigt wird. Da die Messungen unter freier Atmung durchgeführt werden und keine zusätzlichen externen Messgeräte angeschlossen werden müssen, stellte die Untersuchung für die Patienten in dieser Arbeit kein Problem dar. Im ersten Teil dieser wurde Arbeit gezeigt, dass sich mit Hilfe des DC Signales als Navigator und einer retrospektiven Datenauswahl das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung von beispielsweise 1.6 x 1.6 x 4 mm3 innerhalb von 13 min. darstellen lässt. Die Anwendbarkeit der vorgestellten Methode zur Bewegungskorrektur wurde neben Probanden auch an Patienten demonstriert. Da wie bereits beschrieben das Bildgebungsvolumen mehrfach abgetastet werden muss, wiederholt sich auch die Abfolge der für die Bildgebung verantwortlichen Gradienten periodisch. Da sich der Atemzyklus aber auch periodisch wiederholt, kann es zu Korrelationen zwischen der Atmung und den wiederholten Messungen kommen. Dies führt dazu, dass auch nach vielen wiederholten Messungen immer noch größere Bereiche fehlender Linien im k-Raum bleiben, was zu Artefakten in den Rekonstruktionen führt. Dies konnte im Falle der konventionellen Bewegungskorrektur in den Gatingmasken, die die Verteilung und Häufigkeit der einzelnen akzeptierten Phasenkodierschritte im k-Raum zeigen, beobachtet werden. Da eine vorsätzliche Unterbrechung der Atemperiodizität (der Patient wird dazu angehalten, seine Atemfrequenz während der Messung absichtlich zu variieren) zur Vermeidung der angesprochenen Korrelationen nicht in Frage kommt, musste die Periodizität in der Datenaufnahme unterbrochen werden. In dieser Arbeit wurde dies durch eine quasizufällige Auswahl von Phasen- und Partitionskodiergradienten erreicht, da Quasizufallszahlen so generiert werden, dass sie unabhängig von ihrer Anzahl einen Raum möglichst gleichförmig ausfüllen. Die quasizufällige Datenaufnahme führt deshalb dazu, das sowohl akzeptierte als auch fehlende Linien nach der Bewegungskorrektur homogen im k-Raum verteilt auftreten. Vergleicht man das auftreten von Ghosting zeichnen sich die quasizufälligen Rekonstruktionen im Vergleich zur konventionellen Datenaufnahme durch eine verbesserte Reduktion von Ghost Artefakten aus. Dies ist auf die homogene Verteilung mehrfach akzeptierter Linien im k-Raum zurückzuführen. Die homogenere Verteilung von fehlenden Linien im k-Raum führt weiterhin zu einer wesentlich stabileren Rekonstruktion fehlender Linien mit parallelen MRT-Verfahren (z.B. iterativem Grappa). Dies wird umso deutlicher je höher der Anteil fehlender Linien im k-Raum wird. Im Falle der konventionellen Datenaufnahme werden die zusammenhängenden Bereiche fehlender Linien immer größer, was eine erfolgreiche Rekonstruktion mit iterativem Grappa unmöglich macht. Im Falle der quasizufälligen Datenaufnahme dagegen können auch Datensätze in denen 40% der Linien fehlen einfaltungsartefaktfrei rekonstruiert werden. Im weiteren Verlauf der Arbeit wurde gezeigt, wie die Stabilität der iterativen Grappa Rekonstruktion im Falle der quasizufälligen Datenaufnahme für eine erhebliche Reduktion der gesamten Messzeit genutzt werden kann. So ist in einer Messzeit von nur 74s die Rekonstruktion eines artefaktfreien und bewegungskorrigierten dreidimensionalen Datensatzes der menschlichen Lunge mit einer Auflösung von 2 x 2 x 5 mm3 möglich. Des Weiteren erlaubt die quasizufällige Datenaufnahme in Kombination mit iterativem Grappa die Rekonstruktion von Datensätzen unterschiedlicher Atemphasen von Inspiration bis Expiration (4D Bildgebung). Nach einer Messzeit von 15min. wurden 19 unterschiedliche Atemzustände rekonstruiert, wobei sich der Anteil der fehlenden Linien zwischen 0 und 20 % lag. Im Falle der konventionellen Datenaufnahme wäre eine wesentlich längere Messzeit nötig gewesen, um ähnliche Ergebnisse zu erhalten. Zum Schluss soll noch ein Ausblick über mögliche Weiterentwicklungen und Anwendungsmöglichkeiten, die sich aus den Erkenntnissen dieser Arbeit ergeben haben, gegeben werden. So könnte das quasizufällige Aufnahmeschema um eine Dichtegewichtung erweitert werden. Hierbei würde der zentrale k-Raum Bereich etwas häufiger als die peripheren Bereiche akquiriert werden. Dadurch sollte die iterative Grappa Rekonstruktion noch stabiler funktionieren und Ghost Artefakte besser reduziert werden. Die Verteilung der Linien sollte allerdings nicht zu inhomogen werden, um größere Lücken im k-Raum zu vermeiden. Darüber hinaus könnte die vorgestellte Methode der Bewegungskompensation auch für die Untersuchung anderer Organe oder Körperteile verwendet werden. Voraussetzung wäre lediglich das Vorhandensein dezidierter Spulenanordnungen, mit denen die Bewegung nachverfolgt werden kann. So ist beispielsweise eine dynamische Bildgebung des frei und aktiv bewegten Knies möglich, wobei zwischen Beugung und Streckung durch die erste Ableitung des zentralen k-Raum Signales unterschieden werden kann. Dies kann zusätzliche Diagnoseinformationen liefern oder für Verlaufskontrollen nach Operationen benutzt werden [15]. Eine Weiterentwicklung mit hohem klinischen Potential könnte die Kombination der in dieser Arbeit vorgestellten retrospektiven Bewegungskorrektur mit einer Multi- Gradienten-Echo Sequenz darstellen. Hierzu musste die bestehende Sequenz lediglich um eine mehrfache Abfolge von Auslesegradienten innerhalb einer Anregung erweitert werden. Dies ermöglicht eine bewegungskorrigierte voxelweise Bestimmung der transversalen Relaxationszeit T∗2 in hoher räumlicher Auflösung. Unter zusätzlicher Sauerstoffgabe kann es zu einer Veränderung von T∗2 kommen, die auf den sogenannten BOLD Effekt (Blood Oxygen Level Dependent) zurückzuführen ist. Aus dieser Änderung könnten Rückschlüsse auf hypoxische Tumorareale gezogen werden. Da diese eine erhöhte Strahlenresistenz aufweisen, könnte auf diese Bereiche innerhalb des Tumors eine erhöhte Strahlendosis appliziert und so möglicherweise Behandlungsmisserfolge reduziert werden. Gleichzeitig kann durch die 4D Bildgebung eine mögliche Tumorbewegung durch die Atmung erfasst und diese Information ebenfalls in der Bestrahlungsplanung benutzt werden. Die Lungen MRT könnte somit um eine hochaufgelöste dreidimensionale funktionelle Bildgebung erweitert werden. / The goal of this work was to depict the whole lung volume by MRI in high spatial resolution. To obtain sufficient signal for a reliable diagnosis despite the inherently low proton density of the lung and the requested high spatial resolution, total acquisition times of a few minutes are mandatory. Simultaneously, the measurements should be performed under free breathing conditions making patient examinations more comfortable or possible for patients with limited breath holding capabilities. However, free breathing leads to motion artifacts which can severely influence the diagnostic value of the images and hence have to be avoided. To compensate for motion the prevalent breathing pattern has to be detected. This can be achieved by external measurement devices such as a respiration belt or a spirometer or by conventional navigator echoes using an additional excitation pulse. Drawbacks of these methods are that the respiratory motion is detected only indirectly, that electronic devices have to be used near the MRI machine and the patients have to be prepared and are strongly restricted. Furthermore, additional excitation pulses will prolong the total acquisition time and may affect the magnetization adversely. To overcome these limitations of motion detection in the present work, the image as well as the navigator data was acquired within one excitation of a FLASH sequence. The resulting central k-space signal (DC signal) after rephasing of all imaging gradients was used as a navigator signal. The DC signal represents the sum of all signals that can be detected with a single receiver coil element. If the liver is for example moving in the sensitivity area of one coil element due to breathing, an increased DC signal will be detected. Depending on their local position on the body the locally confined coil elements are able to track respiratory motion. The time course of the DC signal of the selected coil element for respiratory motion compensation will depict periodic signal variations accordingly. Additionally, respiratory phases of expiration can be distinguished from inspiratory phases because the resting times in end-expiratory phases are usually longer compared to end-inspiratory phases. The DC signal can be acquired either before or after the actual image data acquisition within one excitation. The short T2* of the human lung tissue leads to a rapid signal decay after the excitation. As shown in this thesis, the DC signal should be acquired after the image data within one excitation. This approach allows for echo time (TE) reduction of 0.3 ms leading to a signal benefit of approximately 20 %. Simultaneously, the remaining signal after image data acquisition and rephasing of all imaging gradients is still sufficient to track respiratory motion and can therefore be used for motion compensation of the acquired data. In order to compensate for motion retrospectively, threshold values for data acceptance have to be defined. Setting the threshold value, neither too less nor too much data should be accepted. Accepting very few data leads to sharp transition between the lung and the diaphragm because not much motion is allowed in the reconstruction process. On the other hand, disturbed signal intensity can be observed because of under-sampling artifacts due to missing lines after gating. These artifacts can restrict the diagnostic value of the reconstructions. Therefore, the selected threshold value should lead to a fully sampled k-space after gating. This requirement can be used to define the maximum threshold value for data acceptance. On the contrary, accepting very much data leads to higher signal intensity but also to more distinctive motion artifacts. In this case, the physician has to decide whether the motion artifacts affect his diagnosis too much. A moderate threshold value leads to a fully sampled k-space as well as good motion artifact compensation. This results in reconstructions that are characterized by a sharp depiction of small vessels even near the diaphragm. For this, threshold values leading to a data acceptance of about 40 % turned out to be beneficial. To avoid under-sampling artifacts because of retrospective gating, the imaging volume has to be acquired several times. This ensures that enough data is available for the final reconstruction whereas multiple accepted data is averaged. Averaging is essential for the reconstruction of high resolution data sets because of the inherently low proton density of the lung. Furthermore it leads to the reduction of ghost artifacts as is shown using the example of heart motion in this work. As no external measurement devices were used and the data was acquired under free breathing conditions the examinations posed no problem for the patients within this work. It was shown so far that the DC signal in combination with retrospective gating can be used to reconstruct high resolution 3d lung data sets with a resolution of 1.6 x 1.6 x 4 mm3 within 13 min., for instance. The applicability of the presented method for motion compensation was shown for volunteers as well as patients. Since as already described the imaging volume must be acquired several times, the series of gradients for spatial encoding are repeated periodically. As the respiratory cycle is periodically as well, correlations between the repeated measurements and the breathing cycle can occur. Therefore, even after many repeated measurements large areas of missing k-space lines can remain, leading to artifacts in the reconstructions. This can be observed in the gating masks, showing the distribution of accepted and missing lines in k-space, in case of conventional motion compensation used in this work so far. To avoid the aforementioned correlations, the periodicity in the repeated acquisitions has to be interrupted because of suspending the periodic breathing pattern of patients deliberately would be a serious intervention and is therefore ineligible. This was accomplished by a quasi-random selection of the phase and partition encoding gradients as quasi-random numbers are generated to fill the space as uniformly as possible regardless of their number. Therefore, accepted lines as well as missing lines are uniformly distributed in k-space after retrospective gating. A more uniform distribution of multiple accepted k-space lines in case of quasirandom sampling leads to an improved reduction of Ghost-Artifacts compared to conventional sampling. Furthermore, the more uniform distribution of missing kspace lines leads a considerably more stable reconstruction of missing lines using parallel imaging techniques (as iterative Grappa for example). This is getting more distinct the higher the proportion of missing k-space lines is. The contiguous areas of missing k-space lines are becoming increasingly large in case of conventional sampling, making a successful reconstruction using iterative Grappa impossible. In contrast, quasi-random sampling enables for the successful reconstruction of artifact free images even when 40 % of the acquired lines were missing after retrospective gating. In addition, the stability of the iterative GRAPPA reconstructions in case of quasirandom sampling allows for a substantial reduction of the total acquisition time. Thus, an artifact free motion compensated data set of 2 x 2 x 5 mm3 resolution could be reconstructed for a measurement time of only 74s. Furthermore, quasi-random sampling in combination with iterative Grappa enables for the reconstruction of data sets of different respiratory phases from inspiration to expiration (4d imaging). Accordingly, 19 different respiratory phases could be reconstructed after 15min of data acquisition. The percentage of missing lines was between 0 and 20 %. Hence, in case of conventional sampling a considerably longer measurement time would have been required to achieve similar results.
2

Traveling Wave Magnetic Particle Imaging / Traveling Wave Magnetic Particle Imaging

Vogel, Patrick January 2016 (has links) (PDF)
Magnetic Particle Imaging (MPI) ist eine noch sehr junge Technologie unter den nicht-invasiven tomographischen Verfahren. Seit der ersten Veröffentlichung 2005 wurden einige Scannertypen und Konzepte vorgestellt, welche durch die Messung des Antwortsignals von superparamagnetischen Eisennanopartikeln (SPIOs) auf wechselnde Magnetfelder ein dreidi-mensionales Bild ihrer Verteilung berechnen können. Durch die direkte Messung des Tracers handelt es sich beim MPI um eine sehr sensitive und hochspezifische bildgebende Methode. Zu Beginn dieser Forschungsarbeit gab es nur wenige bekannte MPI-Scanner, die jedoch alle ein nur kleines Field-of-View (FOV) vorweisen konnten. Der Grund dafür liegt in der Ver-wendung von Permanentmagneten. Das Ziel war es nun, ein neues Konzept auszuarbeiten und einen 3D-MPI-Scanner zu entwer-fen, der in der Lage ist, ein mausgroßes Objekt zu messen. In dieser Arbeit wird ein alternatives Scannerkonzept für die dreidimensionale Bildge-bung superparamagnetischer Eisennanopartikel vorgestellt. Der Traveling Wave MPI-Scanner (TWMPI) basiert auf einem neu entwickelten Hauptspulensystem, welches aus mehreren Elektromagneten besteht. Dadurch ist die Hardware bereits in der Lage, eine Linie entlang der Symmetrieachse über einen großen Bereich dynamisch zu kodieren. Mit Hilfe weiterer Ab-lenkspulen kann schließlich ein FOV von 65 x 25 x 25 Millimetern dreidimensional abgetastet werden. Dazu stehen mehrere Scanverfahren zur Verfügung, welche das Probenvolumen li-nienweise oder ebenenweise abtasten und mit einer Auflösung von ca. 2 Millimetern die Ver-teilung der SPIOs in wenigen Millisekunden abbilden können. Mit diesem neuen Hardwareansatz konnte erstmals ein MPI-Scanner mit einem MR-Tomographen (MRT) kombiniert werden. Das MPI/MRT-Hybridsystem liefert tomographi-sche Bilder des Gewebes (MRT) und zeigt die Verteilung des eisenhaltigen Kontrastmittels (MPI), ohne die Probe bewegen zu müssen. In einer in-vivo Echtzeitmessung konnte der TWMPI-Scanner mit 20 Bildern pro Se-kunde die dynamische Verteilung eines eisenhaltigen Kontrastmittels im Körper und speziell im schlagenden Herzen eines Tieres darstellen. Diese Echtzeitfähigkeit eröffnet in der kardi-ovaskuläre Bildgebung neue Möglichkeiten. Erste Messungen mit funktionalisierten Eisenpartikeln zeigen die spezifische Bildge-bung verschiedener Zelltypen und stellen einen interessanten Aspekt für die molekulare Bild-gebung dar. Die Sensitivität des Scanners liegt dabei im Bereich von wenigen Mikrogramm Eisen pro Milliliter, was für den Nachweis von wenigen 10.000 mit Eisen markierten Zellen ausreicht. Neben Messungen an diversen Ferrofluiden und eisenhaltigen Kontrastmitteln konnte der Einfluss von massiven Materialen, wie Eisenstückchen oder Eisenspänen, auf die rekon-struierten Bilder untersucht werden. Erste Messungen an Gestein zeigen die Verteilung von Eiseneinschlüssen und bieten die Möglichkeit einer weiteren zerstörungsfreien Untersuchungsmethode für Materialwissen-schaftler und Geologen. Weiterführende Testmessungen mit einer unabhängigen μMPI-Anlage zeigen erste Ergebnisse mit Auflösungen im Mikrometerbereich und liefern Erkennt-nisse für den Umgang und Messung mit starken Gradientenfeldern. Eine Modifizierung der Messanlage erlaubt es, in gerade einmal 500 μs ein komplettes Bild aufzunehmen, womit die Bewegung eines Ferrofluidtropfens in Wasser sichtbar gemacht werden konnte. Damit ist diese TWMPI-Anlage das schnellste MPI-System und eröffnet die Möglichkeit grundlegende Erfahrungen in der Partikeldynamik zu erlangen. Der vorgestellte Traveling Wave MPI-Scanner ist ein alternativer Scannertyp, welcher sich von anderen MPI-Scannern abhebt. Mit neuen Ansätzen ist in der Lage ein mausgroßes Objekt auf dynamische Weise sehr schnell abzutasten. Dabei konnten in verschiedenen Mes-sungen die Funktionalität und Leistungsfähigkeit des TWMPI-Konzeptes demonstriert wer-den, welche die gesteckten Ziele deutlich übertreffen. / Magnetic particle imaging (MPI) is still a very young technology among the non-invasive tomographic modalities. Since its first publication in 2005, several types of scanners and concepts were presented, which can reconstruct a three-dimensional image of the distri-bution of superparamagnetic iron-oxide nanoparticles (SPIOs) by measuring their magnetiza-tion response to varying magnetic fields. Due to the direct measurement of the tracer MPI is a very sensitive and highly specific imaging modality. At the beginning of this project only a few MPI-scanners were known, but all of them are limited to a small field-of-view (FOV). The reason for this is the use of permanent mag-nets. The aim of this work was to develop a new concept and design for a 3D-MPI-scanner, which is able to measure a mouse sized object. In this thesis an alternative scanner concept for three-dimensional imaging of super-paramagnetic iron nanoparticles is presented. The Traveling Wave-MPI-scanner (TWMPI) is based on a newly developed main coil system, which consists of a series of electromagnets. This coil array is by itself able to dynamically encode a line along the symmetry axis over an extended length. With additional offset coils the system is able to scan a FOV of 65 x 25 x 25 millimeters in three dimensions. For scanning the whole volume several tech-niques are available, which map the data line-by-line or slice-by-slice in a few milliseconds and yield the distribution of SPIOs with a resolution of about 2 millimeters. Using this new hardware approach a MPI-scanner was successfully combined with an MRI-scanner for the first time. The MPI/MRI-hybrid-system provides tomographic images of the tissue (MRI) and detects the distribution of iron-containing contrast agent (MPI), without the need to move the sample. In an in-vivo real-time measurement using the TWMPI-scanner the dynamic distribu-tion of an iron-containing contrast agent was visualized in the body and especially in the beat-ing heart of an animal with a temporal resolution of 20 frames per second. This real-time ca-pability opens up new possibilities in cardio-vascular imaging. First measurements using functionalized iron-oxide nanoparticles specifically detect different cell types and thereby provide an interesting aspect for molecular imaging. The sensi-tivity of the scanner is in the range of a few micrograms of iron per milliliter, which is suffi-cient to detect about 50,000 iron-labeled cells. In several studies the influence of various ferrofluids, iron-containing contrast agents and solid materials, such as pieces of iron or iron filings, were examined on the reconstructed images. First measurements on ferrous rock show the location of iron-inclusions and offer an-other non-destructive imaging technique for material scientists and geologists. Additional tests with an independent μMPI-system were performed to explore resolutions in the micrometer range and provide insights for handling and measuring with a high gradient strength. A modification of the setup allows to acquire a full slice in just 500 microseconds, which enable the visualization of the motion of a droplet of ferrofluid in water. With this TWMPI is the fastest MPI-system available and gives access to fundamental studies of particle dynamics. The presented Traveling Wave MPI-system is an alternative scanner concept, which sets itself apart from other MPI-scanners. Mouse-sized objects can be imaged in a dynamic way in very short times. The feasibility and performance of the TWMPI-concept were suc-cessfully demonstrated in various measurements considerably exceeding the original aims.
3

T1 und T2*-Quantifizierung in der menschlichen Lunge / T1 and T2* quantification in the human lung

Triphan, Simon January 2015 (has links) (PDF)
In dieser Arbeit werden für die Anwendung in der menschlichen Lunge optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert: Dc-Gating ermöglicht die Quantifizierung in freier Atmung, wobei für die T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus mehreren Messungen anhand ihrer dc-Signale passend überlagert werden können. Da T1 und T2* auf unterschiedliche Art und Weise von der Sauerstoffkonzentration abhängen, verbessert dies die Möglichkeit, ΔT1- und ΔT2*- Differenzkarten aus Messungen mit unterschiedlichen O2-Konzentrationen im Atemgas zu erstellen. Die Parameterquantifizierung ist in erster Linie für die Beobachtung von Krankheitsverläufen interessant, da T1 und T2* absolute, vergleichbare Zahlen sind. Da T2* deutlich vom Atemzustand abhängt, ist es auch hierfür sinnvoll, durch Gating identische Atemzustände abzubilden. Um die unterschiedlichen Einflüsse des Sauerstoffs auf T1 und T2* besser vergleichbar zu machen, wurde in dieser Arbeit weiterhin eine kombinierte Messung für beide Parameter implementiert: Da auch diese in freier Atmung stattfindet, profitieren nicht nur die Differenzkarten von der Überlagerung der Bilder, sondern auch der Vergleich der ΔT1- und ΔT2*-Karten untereinander. Messungen mit einer konventionellen kartesischen Methode an COPD-Patienten unter Raumluft- und 100% Sauerstoffatmung ergaben bei Verwendung identischer Atemmasken ein deutlich geringeres ΔT1 als in gesunden Probanden. Dass T1 in der Lunge nicht nur von der Sauerstoffkonzentration sondern auch von der Gewebezusammensetzung und insbesondere auch dem Blutvolumenanteil abhängt, zeigte sich hierbei aber auch an den bei COPD im Mittel sehr viel kürzeren T1-Zeiten bei Raumluft. Die aufgrund emphysematischer Veränderung noch zusätzlich reduzierte Protonendichte im Parenchym kranker Lungen macht diese Messungen allerdings besonders schwierig. Die oben erwähnten Optimierungen der T1-Quantifizierung zielen daher auch darauf ab, das Signal aus der Lunge zu maximieren, um Patientenmessungen einfacher zu machen: Messungen in freier Atmung sind für Patienten nicht nur einfacher, sondern erlauben effektiv auch längere Messzeiten. Insbesondere wurde aber durch die Entwicklung einer radialen Methode die Echozeit zur Messung reduziert, um die kurze T2*-Zeit in der Lunge auszugleichen. Schließlich wurde durch Implementation einer 2D UTE Sequenz die Messung bei der kürzesten vom Scanner erlaubten Echozeit ermöglicht. Die Messungen bei ultrakurzen Echozeiten in Probanden zeigten allerdings deutlich kürzere T1-Zeiten als die zuvor gefundenen oder in der Literatur dokumentierten. In weiteren Experimenten wurde das sichtbare T1 zu mehreren Echozeiten mit Hilfe der zur kombinierten Quantifizierung entwickelten Methode bestimmt. Dabei ergab sich eine Zunahme des gemessenen T1 mit der Echozeit. Aus diesem Verhalten sowie den gefundenen kürzesten und längsten T1 lässt sich schließen, dass das intra- und extravaskuläre Lungenwasser, also Blut bzw. das umgebende Gewebe, mit unterschiedlichen T1- und T2*-Zeiten zum Signal und damit auch dem effektiven T1 beitragen. Dass das TE der Messung die Gewichtung dieser Kompartimente bestimmt, hat dabei mehrere Auswirkungen: Einerseits bedeutet dies, dass beim Vergleich von T1-Messungen in der Lunge stets auch das TE mitbetrachtet werden muss, bei dem diese durchgeführt wurden. Andererseits lässt sich die Möglichkeit, die Messung auf die unterschiedlichen Kompartimente abzustimmen, potentiell ausnutzen, um zusätzliche diagnostische Informationen zu gewinnen: Da T1 vom Blutvolumenanteil und der Gewebezusammensetzung abhängt, könnte dieser Effekt helfen, diese beiden Einflüsse zu differenzieren. Während die in dieser Arbeit beschriebenen Experimente die TE-Abhängigkeit des sichtbaren T1 in Probanden aufzeigen, liefern sie allerdings noch keine genaue Erklärung für die möglichen Ursprünge dieses Effekts. Um diese weiter zu untersuchen, könnten allerdings gezielte Phantom- und in vivo-Experimente Aufschluss geben: Ein Aufbau, der die Feldverzerrung durch luftgefüllte Alveolen in Lösungen mit entsprechenden verschiedenen Suszeptibilitäten nachbildet, reduziert den Unterschied zwischen den Kompartimenten auf T1 und χ. Eine in vivo-Messung mit möglichst großer Differenz zwischen Ex- und Inspiration hingegen könnte den Einfluss der Abstände der Kompartimente vom Gasraum aufzeigen, da die Alveolarwände in tiefer Inspiration am weitesten gedehnt und daher am dünnsten sind. / In this work, methods for the local measurement of T1 and T2* maps optimized for the application in the human lungs are discussed: Quantification during free breathing was enabled by applying dc-gating, where a correction for the dc-signal acquired during T1-quantification using a inversion recovery was introduced. This is especially useful to achieve parameter maps in identical breathing states from multiple measurements using their dc-signals. Since T1 and T2* depend on the oxygen concentration through different mechanisms, this is especially interesting to produce ΔT1- and ΔT2*-difference maps at varying O2-concentrations in the breathing gas. Parameter quantification is primarily interesting for the monitoring of the courses of disease or therapy since T1 and T2* are absolute, comparable numbers. As T2* depends significantly on the respiratory state, ensuring identical states via gating is relevant there as well. To further improve the comparison of oxygen influence on T1 and T2* a method for the combined measurement of both parameters was implemented: Since this is also employs gating, not only the difference maps benefit from image coregistration, but the comparison of the ΔT1 and ΔT2* maps to each other as well. Measurements using the conventional cartesian method on COPD patients under room air and pure oxygen conditions resulted in much lower ΔT1 than in healthy volunteers when using identical oxygen masks. The much lower average T1 times at room air found there demonstrate that T1 in the lungs not only depends on the oxygen concentration but also on tissue composition and especially the blood volume fraction. Proton densities that were reduced even further due to emphysematous destruction made these measurements additionally difficult. Accordingly, the optimizations for T1 quantification mentioned above are intended to maximize signal from the lung parenchyma to improve patient measurements: Measurements during free breathing are not only easier for patients but effectively also allow for longer acquisition times. In particular the developement of a radial method provides a shorter echo time to help compensate for the short T2* in the lungs. Finally, the implementation of a 2D UTE sequence enables the measurement at the shortest echo time available on the scanner hardware. However, the measurements at ultra short echo times in volunteers showed significantly shorter T1 times than those found previously and those reported in the literature. In further experiments, the observable T1 was determined at multiple echo times using the method developed for simultaneous quantification. This revealed a gradual increase of the measured T1 with the echo time. From this behaviour as well as the shortest and longest times found, it can be concluded that the intra- and extravascular compartments of lung water, essentially blood and the surrounding tissue, contribute with different T1 and T2* times to the MR signal and thus also the effective T1. That the echo time of the measurement determines the weighting of these compartments has multiple consequences: Firstly, this means that when comparing T1 measurements in the lungs, the echo time that was used to acquire them also has to be considered. Secondly, the possiblity to focus the measurement on these different compartments might be used to gain additional diagnostic information: Since T1 depends on blood volume content and tissue composition, this effect might help to differentiate these two influences. While the experiments described in this work demonstrate the echo time dependence of the observed T1 in volunteers, they do not yet provide an explanation for the exact origins of this effect. To examine these further, appropriate phantom and in vivo experiments could be insightful: A phantom design that simulates the field distortion caused by air-filled alveoli in solutions with suitable susceptibilites would reduce the difference between the compartments to T1 and χ. A in vivo measurement with an especially large difference between ex- and inspiration could help to show the influence of the distance of the compartments from the gas space, since the alveolar walls are most dilated and thus thinnest during deep inspiration.
4

Entwicklung klinischer Methoden zur Quantifizierung der longitudinalen Relaxationszeit T1 in der MRT / Development of clinical methods for quantifying the longitudinal relaxation time T1 in MRI

Gensler, Daniel January 2014 (has links) (PDF)
Die Aufgabenstellung in der vorliegenden Arbeit bestand in der Entwicklung und Umsetzung neuer T1-Quantifizierungsverfahren, die zuverlässig in der klinischen Routine angewendet werden können. Die ausgearbeiteten Techniken umfassten dabei zwei Hauptarbeitsschwerpunkte. Zum einen die Implementierung einer neuartigen dynamischen T1- Thermometriemethode für MR-Sicherheitsuntersuchungen medizinischer Geräte und Implantate, wie beispielsweise Kathetern oder Herzschrittmachern, und zum anderen die Entwicklung eines robusten kardialen T1-Mapping-Verfahrens, welches auch bei stärker erkrankten Patienten mit eingeschränkter Atemanhaltefähigkeit stabil anwendbar ist. Mit der entwickelten kombinierten Heiz- und T1-Thermometriesequenz konnte ein neues Verfahren präsentiert werden, mit dem ein zu untersuchendes medizinisches Gerät oder Implantat kontrolliert erwärmt und die Temperaturänderung zeitgleich präzise erfasst werden kann. Dabei war es möglich, die HF-induzierte Erwärmung der metallischen Beispielimplantate sowohl in homogenem Gel als auch in inhomogenem Muskelgewebe exakt und ortsaufgelöst zu quantifizieren. Die MR-technisch errechneten Temperaturwerte zeigten dabei eine sehr gute Übereinstimmung zu den ermittelten Referenzwerten mit einer Temperaturabweichung von meist weniger als 1K. Die Ergebnisse zeigen, dass es mit der präsentierten Methode möglich ist, die räumliche Temperaturverteilung in einem großen Bereich mit einer einzigen Messung quantitativ zu erfassen. Dies ist neben der Nichtinvasivität der Methode der größte Vorteil im Vergleich zu der Einzelpunktmessung mittels eines bei solchen Messungen sonst zumeist verwendeten fluoroptischen Temperatursensors. Bei gestreckten Implantaten kann demnach idealerweise das gesamte Objekt während einer einzigen Messung auf potentielle Temperaturänderungen oder sogenannte Hotspots untersucht werden, was bei der Verwendung von Temperatursensoren lediglich mit großem Zeitaufwand möglich ist, da hier die Temperatur jeweils nur punktuell erfasst werden kann. Im Vergleich zu anderen publizierten MR-Thermometrieverfahren, welche auf der PRF-Technik basieren, bietet die hier präsentierte Methode vor allem den Vorteil, dass hiermit auch eine präzise Temperaturquantifizierung in inhomogenem biologischem Gewebe mit starken Suszeptibilitätsunterschieden wie beispielsweise zwischen Herz und Lunge möglich ist. Somit stellt die Methode ein leistungsstarkes Hilfsmittel für nicht-invasive MR-Sicherheitsuntersuchungen nicht nur an medizinischen Implantaten sondern beispielsweise auch für MR-geführte Interventionen dar. Mit der entwickelten kardialen T1-Mapping-Sequenz TRASSI wurde eine leistungsstarke Methode zur exakten und hoch aufgelösten Generierung kardialer T1-Karten in äußerst kurzer Messzeit (< 6 s) vorgestellt. Durch ihre außerordentliche Robustheit sowohl gegenüber Bildartefakten als auch Herzrhythmusstörungen während der Datenakquisition bietet die Sequenz deutlich verbesserte Möglichkeiten für die Diagnostik verschiedener Herzerkrankungen. Aufgrund der sehr kurzen Akquisitionszeit wird insbesondere auch die Generierung von T1-Karten bei schwer erkrankten Patienten mit kurzer Atemanhaltefähigkeit ermöglicht. Im Vergleich zu derzeit üblicherweise verwendeten alternativen Verfahren wie etwa MOLLI, konnten die T1-Karten mit vergleichbarer Bildauflösung in bis zu 70% kürzerer Messzeit akquiriert werden. Die Ergebnisse der durchgeführten Phantommessungen belegen außerdem, dass die Methode exaktere T1-Werte liefert als dies beispielsweise mit MOLLI möglich ist. Des Weiteren weist TRASSI im Gegensatz zu MOLLI keine T1-Abhängigkeit von der Herzrate auf, wodurch die vorgestellte Technik besonders für diagnostische Studien geeignet ist, welche eine sehr hohe Genauigkeit und Reproduzierbarkeit im Zeitverlauf oder zwischen verschiedenen Patienten erfordern. Mit TRASSI konnten die Strukturen des Herzens bei den durchgeführten in vivo Untersuchungen durchweg mit scharfen Kanten und ohne Bewegungsartefakte dargestellt werden. Dabei wurde unabhängig von der Herzrate und der Bildebene stets eine sehr gute Bildqualität erreicht. Der Hauptgrund hierfür ist vermutlich in der sehr kurzen Akquisitionszeit und der radialen Datenaufnahme zu sehen. Beide Verfahren reduzieren Artefakte aufgrund von Bewegungen wie beispielsweise Herzschlag und Atmung erheblich. Die aufgenommenen T1-Karten zeigen bei allen Probanden und Patienten eine gute diagnostische Bildqualität. So konnten auch die infarzierten Bereiche bei Patienten mit Myokardinfarkt deutlich visualisiert und quantitativ erfasst werden. Nochmals hervorzuheben ist die beobachtete besondere Robustheit der TRASSI Methode gegenüber Artefakten beziehungsweise T1-Quantifizierungsfehlern bei Patienten mit Herzrhythmusstörungen. Auch bei untersuchten Patienten mit starken Arrhythmien während der Bildgebung konnte eine sehr gute Bildqualität und Genauigkeit der errechneten T1-Karten erreicht werden. Die Ergebnisse der Extrazellularvolumen-Quantifizierung zeigen zudem, dass mittels TRASSI auch weiterführende diagnostische Methoden entwickelt und angewandt werden können. Dabei konnten durch Rückrechnung hochaufgelöster und präziser Extrazellularvolumen-Karten beispielsweise Infarktbereiche deutlich visualisiert und signifikante Unterschiede zwischen akut und chronisch infarziertem Herzmuskelgewebe nicht nur identifiziert sondern auch quantitativ charakterisiert werden. Somit ist diese Methode insbesondere für eine potentielle Differenzierung zwischen reversibel und irreversibel geschädigten Herzarealen interessant. Für die Zukunft ist es wünschenswert, weitergehende Untersuchungen an verschiedenen spezifischen Herzerkrankungen vorzunehmen. Zu solchen Erkrankungen gehören beispielsweise die Herzmuskelentzündung (Myokarditis) oder Herzklappenerkrankungen. Diese Krankheitsbilder sind hinsichtlich einer möglichen transienten oder permanenten Schädigung des Herzmuskels mit den bisher verfügbaren Verfahren nur sehr schwer oder lediglich im weit fortgeschrittenen Stadium exakt diagnostizierbar. Die vorgestellte TRASSI-Sequenz bietet hier eine gute Möglichkeit für eine frühzeitige Erkennung der Auswirkungen solcher Erkrankungen auf den Herzmuskel. Weiterführende Untersuchungen der TRASSI-Methode zu deren Robustheit gegenüber spezifischen Herzrhythmusstörungen und ein umfassender Vergleich zum bereits etablierten MOLLI-Verfahren könnten darüber hinaus die Alltagstauglichkeit von TRASSI weiter spezifizieren und den Weg in die klinische Routine ebnen. Die bereits dargelegten positiven Ergebnisse des Verfahrens lassen vermuten, dass TRASSI potentiell ein sehr gutes nicht-invasives Diagnoseverfahren für verschiedenste Herzerkrankungen darstellt. Im Vergleich zu bereits bestehenden Techniken liegen die Vorteile der TRASSI-Methode nach den bisher vorliegenden Ergebnissen zusammenfassend vor allem in der Generierung diagnostisch verlässlicherer T1-Werte bei gleichzeitig verringerter Messzeit, wodurch das Verfahren insbesondere auch für schwer erkrankte Patienten mit starken Arrhythmien und eingeschränkter Atemanhaltefähigkeit geeignet ist. TRASSI ist darüber hinaus aber auch für MR-Untersuchungen im Hochfeld besser geeignet als entsprechende bSSFP-basierende Verfahren wie beispielsweise MOLLI. Dies liegt vor allem daran, dass TRASSI eine Gradientenecho-basierte Bildgebungsmethode ist und somit eine niedrige spezifische Absorptionsrate aufweist. Zudem sind Gradientenecho-Sequenzen allgemein weniger empfindlich gegenüber Suszeptibilitätsartefakten, so dass beispielsweise metallische Implantate bei Patienten sich weniger störend auf die erreichbare Bildqualität auswirken. In der vorliegenden Arbeit wurde sowohl eine exakte T1-Thermometriesequenz als auch eine sehr schnelle und präzise kardiale T1-Mapping-Methode vorgestellt. Für zukünftige Arbeiten ist es wünschenswert, beide Sequenzen bzw. deren Mechanismen zu vereinen und eine Temperaturquantifizierung am Herzen praktisch durchzuführen. Dies wäre zum einen für MR-Sicherheitsuntersuchungen von Schrittmacherelektroden in vivo vorteilhaft, und zum anderen wäre hiermit eine direkte Erfolgskontrolle während einer Katheterablation realisierbar. Eine solche Ablationsbehandlung könnte durch eine genaue Lokalisierung des behandelten - also erhitzten - Herzareals sehr viel präziser durchgeführt werden, wodurch auch bei komplexeren Ablationen die Behandlungserfolge erhöht werden könnten. In einer ersten Veröffentlichung hierzu konnte bereits gezeigt werden, dass eine MR-gestützte Katheterablation die Heilungs- und Erfolgsaussichten des Eingriffes steigern kann. Dieses Verfahren könnte potentiell mit Hilfe einer Echtzeittemperaturüberwachung basierend auf dem TRASSI-Verfahren noch weiter verbessert werden. In Zusammenfassung wurden in dieser Arbeit zwei neue T1-Quantifizierungsverfahren entwickelt und vorgestellt, die voraussichtlich zuverlässig im klinischen Alltag angewendet werden können und neue nicht-invasive diagnostische Möglichkeiten eröffnen. Die implementierten Sequenzen ermöglichen dabei zum einen eine exakte Temperaturquantifizierung und zum anderen ein präzises kardiales T1-Mapping. Beide Verfahren versprechen dabei robuste und reproduzierbare Ergebnisse und könnten in Zukunft den Weg in die klinische Routine finden und so bei einer fundierten Diagnostik verschiedenster Herzerkrankungen behilflich sein. / The goal of the present study was to develop and implement new T1-quantification methods that can be reliably applied in clinical practice. The elaborated techniques focused on two main objectives: first, the implementation of a novel dynamic T1-thermometry technique for MR-safety investigations of medical devices and implants, such as catheters or pacemakers; and second, the development of a robust cardiac T1-mapping method, which is applicable even in severely ill patients with limited breath-hold capabilities. With the newly developed combined heating and T1-thermometry sequence, a new MR method was presented, which allowed a controlled heating of a medical device or implant under investigation, while simultaneously detecting temperature changes near these devices with high accuracy. With this MR sequence it was possible to quantify and spatially accurately resolve the radio frequency-induced heating of exemplary metallic implants both in a homogeneous gel phantom and in inhomogeneous porcine muscle. The MR-calculated temperature values showed good agreement with the determined reference values, with a temperature deviation of usually less than 1K. The results show that with the presented method it is possible to quantify the spatial temperature distribution in a large area. This is - in addition to the non-invasiveness of the method - the main advantage compared to the single-point measurement of commonly used fluoroptic temperature sensors: Ideally, elongated implants can be characterized regarding potential temperature changes or hot spots along the whole device during a single MR measurement. Compared to other published MR-thermometry methods based on the PRF technique the presented T1-based technique particularly provides the advantage of a precise temperature quantification even in inhomogeneous biological tissue with strong susceptibility differences such as between the heart and the lungs. Thus, the method represents a powerful tool for non-invasive MR-safety investigations not only for implanted medical devices, but also for MR-guided interventions. With the developed cardiac T1-mapping sequence TRASSI, a powerful technique for the generation of exact, high-resolution cardiac T1-maps acquired in very short measurement time (< 6 s) was presented. Through the extraordinary robustness both to image artifacts and heart rhythm disturbances during data acquisition, this sequence provides significantly improved possibilities for various diagnostic purposes in clinical cardiology. Due to the very short acquisition time, TRASSI particularly offers the possibility for the generation of T1-maps in severely ill patients with short breath-hold capabilities. Compared to currently commonly used alternative MR techniques, such as MOLLI, T1-maps with similar resolution could be acquired in up to 70 % shorter measurement time. Furthermore, the results of the phantom measurements show that TRASSI provides more accurate T1 values than MOLLI. In addition, TRASSI shows - in contrast to MOLLI - no heart rate T1-dependency. Thus, the presented technique is particularly suited for diagnostic studies, which require a very high accuracy and reproducibility over time or between different patients. With TRASSI, the heart morphology could consistently be identified with sharp edges and without any motion artifacts in the performed in vivo studies. The good image quality could be achieved in all measurements regardless of the heart rate and the image plane. The main reason for these findings can be anticipated in the very short acquisition time and the radial data acquisition. Both significantly reduce artifacts due to motion such as heartbeat and breathing. Diagnostic image quality of the T1 maps in patients with myocardial infarction allowed for visualization and spatial T1-quantification in all subjects. Of note is the observed extraordinary robustness of the TRASSI method against artifacts and T1-errors in patients with cardiac arrhythmias. Even in patients with severe arrhythmias during the imaging procedure a very good image quality and accuracy of the calculated T1-maps could be achieved. Moreover, the results of the extracellular volume quantification show that with TRASSI additional diagnostic methods can be developed and applied. The calculation of accurate high-resolution extracellular volume maps was suitable for visualization of infarcted areas in the myocardium. Furthermore, significant differences between acute and chronically infarcted myocardial tissue could not only be visually identified, but also quantitatively characterized. Thus, this method is particularly interesting for a differentiation between reversible and irreversible myocardial injury. For the future, it is desirable to carry out further clinical studies on various specific heart diseases. Such diseases include, for example, inflammation of the heart muscle (myocarditis) or valvular heart diseases. The diagnosis of these diseases regarding a possible damage of the myocardium is currently problematic and only possible in advanced stages using the methods available today. Here, the presented TRASSI sequence provides a favorable opportunity for the early detection of transient or permanent myocardial damage. Further studies of TRASSI for its robustness against specific cardiac arrhythmias and a comprehensive comparison with the already established MOLLI method could further confirm the everyday practicality of TRASSI and pave the way into clinical routine. The already available positive results of TRASSI suggest this method to be well suited as a non-invasive diagnostic technique for various heart diseases. From the experiments available, it can be concluded that, compared to existing techniques like MOLLI, TRASSI provides more accurate T1-values in a simultaneously reduced measurement time. This positions TRASSI particularly suitable for severely ill patients with distinctive arrhythmias and/or reduced breath-hold capabilities. In addition, TRASSI is better suited for high field MR examinations than corresponding bSSFPbased methods such as MOLLI. This is because TRASSI is a gradient echo-based imaging method and thus it has a lower specific absorption rate. Gradient echo-based sequences are also generally less sensitive to susceptibility artifacts and thus interferences caused by metallic implants of correspondent patients show less negative effects on image quality. In the current work an exact T1-thermometry sequence as well as a very fast and accurate cardiac T1-mapping method was presented. For future work, it is desirable to combine these two sequences and their mechanisms to be able to perform accurate temperature quantification in the beating heart. This would be on the one hand beneficial for MR-safety examinations of pacemaker electrodes in vivo, and on the other hand allow for a direct control of success during catheter ablation. Hence, a catheter ablation procedure could be performed with greatly increased spatial accuracy due to precise localization of heat development in the myocardium. Consequently, the safety and outcomes especially in complex ablations could be increased. In a first publication it could be already shown that MR-guided catheter ablation has the potential to increase procedural success in the future. This interventional technique could potentially be further improved by implementation of a real-time temperature visualization using TRASSI. In summary, two new T1-quantification methods have been developed and presented in this work, which can be reliably applied in clinical practice and which are expected to allow for new non-invasive diagnostic possibilities. The implemented sequences allow on the one hand exact temperature quantification in the myocardium and on the other hand accurate cardiac T1-mapping. Both methods promise robust and reproducible results, so that they are expected to find the way into clinical routine, helping in diagnosis and treatment of various heart diseases in the near future.
5

Wave-CAIPI for Accelerated Dynamic MRI of the Thorax / Beschleunigte Dynamische MR-Bildgebung des Thorax mit wave-CAIPI

Richter, Julian Alexander Jürgen January 2021 (has links) (PDF)
In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant. Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI. Dynamic 3D Lung MRI By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures. The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)% lower on average. SNR calculations suggest an average SNR benefit of around 14% for the wave-CAIPI, compared to Cartesian sampling. Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated. Cardiac 4D Flow MRI In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes. By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2. Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed. / Die wave-CAIPI k-Raum Trajektorie stellt eine effiziente Methode für beschleunigte MRT Akquisitionen dar. Die Benutzung der wave-CAIPI Trajektorie anstelle der kartesischen Standardmethode in der parallelen Bildgebung führt zu einem reduzierten Rausch-Niveau in den rekonstruierten Bildern. Dieser Effekt kann durch Berechnungen des Rauschpegels und des Signal-zu-Rausch Verhältnisses (SNR) quantifiziert werden. Das höhere Signal-zu-Rausch Verhältnis kann genutzt werden, um entweder die Akquisition durch eine höhere Unterabtastung zu beschleunigen, oder um die Bildqualität zu verbessern. Die Beschleunigung von MRT Akquisitionen ist besonders in dynamischen Anwendungen wichtig, da diese Untersuchungen inhärent sehr zeitaufwendig sind. Der Einfluss der wave-CAIPI Methode auf die Bildqualität und das Beschleunigungspotenzial der Messung wurde in dieser Arbeit sowohl für selbst-navigierte, dynamische 3D Lungenbildgebung, als auch für 4D Fluss MRTs des Herzens untersucht Dynamische 3D Lungen MRT Durch die Verwendung der wave-CAIPI Samplingmethode konnte die Bildqualität von selbst-navigierten, dynamischen 3D Lungen MRTs bei freier Atmung verbessert werden. Eine wichtige Anwendung dieser Technik liegt im Bereich der Strahlentherapieplanung. Dabei wurde im Rahmen einer Probandenstudie die Bildqualität anhand der Ähnlichkeit zwischen beschleunigten Bildern und den jeweiligen Referenzen quantifiziert. Zu diesem Zweck wurden die normalized mutual information und der root-mean-square error als quantitative Maße gewählt. Es konnte gezeigt werden, dass -- besonders bei kurzen Akquisitionszeiten -- die wave-CAIPI Methode zu besserer Bildqualität führte, verglichen mit dem kartesischen Standard. Berechnungen der normalized mutual information ergaben im Mittel (10.2 +- 7.3)% höhere Werte für die wave-CAIPI Methode -- der root-mean-square error war (18.9 +- 13.2)% geringer. Darüber hinaus lieferte die wave-CAIPI ein um etwa 14% höheres mittleres SNR. In 2 Minuten konnte die Atembewegung der Lunge in 8 Atemzustände aufgelöst werden. Eine präzise Tumor-Abgrenzung und die Evaluierung von respirationsinduzierten Tumorbewegungen wird durch die Verwendung der wave-CAIPI Methode vereinfacht. 4D Fluss Herz MRT Die Beschleunigung von 4D Fluss MRTs ist essentiell, um solche Untersuchungen in die klinische Routine zu integrieren. In der präsentierten Arbeit wurde eine 6-fache retrospektive Beschleunigung realisiert. 4D Fluss Untersuchungen von gesunden Probanden mit der wave-CAIPI und mit der kartesischen Samplingmethode wurden verwendet, um Unsicherheiten in verschiedenen Flussparametern für die beiden Samplingmethoden zu berechnen. Dabei zeigte sich, dass die geschätzten Fehler in den Flussparametern der 6-fach beschleunigten wave-CAIPI Untersuchungen bis zu 55% geringer sind als die Fehler der kartesischen Messungen. Ferner zeigten Rausch-Analysen, dass die beschleunigten wave-CAIPI Aufnahmen ein um 43% geringeres Rausch-Niveau aufweisen. Vergleiche zwischen Flussparametern, die aus 2-fach beschleunigten wave-CAIPI und kartesischen Messungen berechnet wurden, zeigten kleine, aber teilweise statistisch signifikante Unterschiede zwischen den beiden Methoden. Unterschiede zwischen 2-fach und 6-fach beschleunigten wave-CAIPI Aufnahmen sind vergleichbar mit den Unterschieden zwischen der wave-CAIPI Methode und der kartesischen Methode bei R=2. Wave-CAIPI 4D Fluss Aufnahmen des Herzens konnten mit einer mittleren, simulierten Aufnahmezeit von unter 4 Minuten durchgeführt werden. Die effizientere Samplingmethode ermöglichte dabei erheblich reduzierte Unsicherheiten in den berechneten Flussparametern. Wichtige Visualisierungen des Blutflusses in der Aorta wurden im Falle der wave-CAIPI Methode kaum von der Unterabtastung beeinflusst. Hingegen wiesen die Visualisierungen der beschleunigten kartesischen Messungen erhebliche Diskrepanzen auf.
6

Wechselwirkungen zwischen Kantenzuständen auf dem topologisch kristallinen Isolator Pb\(_{1-x}\)Sn\(_x\)Se / Interactions between edge states on the topologically crystalline insulator Pb\(_{1-x}\)Sn\(_x\)Se

Jung, Johannes January 2023 (has links) (PDF)
Einerseits besteht die einfachste Möglichkeit zum Ladungs- und Informationstransport zwischen zwei Punkten in deren direkter Verbindung durch eindimensionale Kanäle. Andererseits besitzen topologische Materialien exotische und äußerst vorteilhafte Eigenschaften, weshalb es nahe liegt, dass schon bald neue Anwendungen aus ihnen realisiert werden. Wenn diese beiden Entwicklungen zusammenkommen, dann ist ein grundlegendes Verständnis von Quanteninterferenz oder Hybridisierungseffekten in eindimensionalen, topologischen Kanälen von fundamentaler Wichtigkeit. Deshalb werden in der vorliegenden Arbeit Wechselwirkungen von eindimensionalen, topologisch geschützten Kantenzuständen, die an ungeradzahligen Stufenkanten auf der (001)–Oberfläche von Pb1−xSnxSe auftreten, untersucht. Aufgrund der lateralen Lokalisierung auf wenige Nanometer um eine Stufenkante herum und der Notwendigkeit zwischen gerad- und ungeradzahligen Stufenkantenhöhen zu unterscheiden, bieten sich die Rastertunnelmikroskopie und -spektroskopie als Methoden an. Die neu entdeckten Kopplungs- bzw. Wechselwirkungseffekte zwischen benachbarten Kantenzuständen treten auf, sobald der Stufe zu Stufe Abstand einen kritischen Wert von dkri ≈ 25nm unterschreitet. Dieses Kriterium kann durch verschiedene räumliche Anordnungen von Stufenkanten erfüllt werden. Infolgedessen werden sich kreuzende, parallel verlaufende und zusammenlaufende Stufenkanten genauer untersucht. Bei letzteren verändert sich entlang der Struktur kontinuierlich der Abstand und damit die Kopplungsstärke zwischen den beiden Randkanälen. Infolgedessen wurden drei Koppelungsregime identifiziert. (I) Ausgehend von einer schwachen Wechselwirkung zeigt der für die Kantenzustände charakteristische Peak im Spektrum zunächst eine Verbreiterung und Verminderung der Intensität. (II) Mit weiter zunehmender Wechselwirkung beginnt sich der Zustand in zwei Peaks aufzuspalten, sodass ab dkri ≈ 15nm an beiden Stufenkanten durchgehen eine Doppelpeak zu beobachten ist . Mit weiter abnehmendem Abstand erreicht die Aufspaltung Werte von einigen 10 meV, während sich die Intensität weiter reduziert. (III) Sobald zwei Stufenkanten weniger als etwa 5nm voneinander getrennt sind, konvergieren aufgrund der schwindenden Intensität und des sinkenden energetischen Abstands der beiden Peaks zu den van Hove Singularitäten die Spektren an den Stufenkanten gegen das Spektrum über einer Terrasse. i Die Aufspaltung verläuft in den Bereichen I und II asymmetrisch, d. h. ein Peak verbleibt ungefähr bei der Ausgangsenergie, während der andere mit zunehmender Kopplung immer weiter weg schiebt. Bezüglich der Asymmetrie kann kein Unterschied festgestellt werden, ob die zusammenlaufenden Stufenkanten eine Insel oder Fehlstelleninsel bilden oder ob die Stufenkanten sogar gänzlich parallel verlaufen. Es zeigt sich keine Präferenz, ob zunächst der niederenergetische oder der hochenergetische Peak schiebt. Erst im Regime starker Kopplung (III) kann beobachtet werden, dass beide Peaks die Ausgangsenergie deutlich verlassen. Im Gegensatz dazu kann bei sich kreuzenden Stufen ein erheblicher Einfluss der Geometrie, in Form des eingeschlossenen Winkels, auf das Spektrum beobachtet werden. Unabhängig vom Winkel existiert am Kreuzungspunkt selbst kein Kantenzustand mehr. Die Zustände an den vier Stufen beginnen, abhängig vom Winkel, etwa 10-15nm vor dem Kreuzungspunkt abzuklingen. Überraschenderweise zeigt sich dabei, dass im Fall rechtwinkliger Stufen gar keine Aufspaltung zu beobachten ist, während bei allen anderen Winkeln ein Doppelpeak festgestellt werden kann. Diese Entdeckung deutet auf Orthogonalität bezüglich einer Quantenzahl bei den beteiligten Kantenzustände hin. Neben einer nur theoretisch vorhergesagten Spinpolarisation kann dieser Effekt auch von dem orbitalem Charakter der beteiligten Dirac–Kegel verursacht sein. Da der topologische Schutz in Pb1−xSnxSe durch Kristallsymmetrien garantiert ist, wird als letzter intrinsischer Effekt der Einfluss von eindimensionalen Defekten auf die Kantenzustände untersucht. Berücksichtigt werden dabei ein nicht näher klassifizierbarer, oberflächennaher Defekt und Schraubversetzungen. In beiden Fällen kann ebenfalls eine Aufspaltung des Kantenzustands in einen Doppelpeak gezeigt werden. Im zweiten Teil dieser Arbeit werden die Grundlagen für eine Wiederverwendung von (Pb,Sn)Se–Oberflächen bei zukünftige Experimenten mit (magnetischen) Adatomen geschaffen. Durch Kombination von Inoenzerstäubung und Tempern wird dabei nicht nur eine gereinigte Oberfläche erzeugt, sondern es kann auch das Ferminiveau gezielt erhöht oder gesenkt werden. Dieser Effekt beruht auf eine Modifikation der Sn– Konzentration und der von ihr kontrollierten Anzahl an Defektelektronen. Als letztes sind erste Messungen an Cu- und Fe–dotierte Proben gezeigt. Durch die Adatome tritt eine n–Dotierung auf, welche den Dirac–Punkt des Systems in Richtung des Ferminiveaus verschiebt. Sobald er dieses erreicht hat kommt es zu Wechselwirkungsphänomenen an freistehenden Stufenkanten. Dies führt zu einer Doppelpeakstruktur mit einer feinen Aufspaltung von wenigen meV. Das Phänomen ist auf ein schmales Energiefenster beschränkt, bei dem die Lage des Dirac–Punkts nur etwa 5 meV (in beide Richtungen) von der des Ferminiveaus abweichen darf. / First, the simplest possibility of transporting charges and information between twopoints is given by there direct connection due to one dimensional channels. Second,topological materials have exotic and extremely advantageous properties, which makethem suitable for further applications. If these two come together, then a basic understandingof quantum interference or hybridization effects in one-dimensional, topologicalchannels is of fundamental importance. Therefore, in the present work, interactionsof one dimensional, topologically protected edge states, hosted at odd numbered stepedges on the (001) surface of (Pb,Sn)Se, are investigated.Due to the lateral localization to a few nanometers around a step edge and the needto differentiate between even and odd numbered step heights, scanning tunneling microscopyand spectroscopy are the tools of choice. The newly discovered coupling orinteraction effects between neighboring edge states appear as soon as their distancedecrease below a critical value of dcri ≈ 25 nm. This criterion can be met by variousspatial arrangements of step edges. As a result, crossing, parallel and converging stepedges are examined more closely.With the latter, the distance and thus the coupling strength between the two edgechannels changes continuously along the structure. As a result, three coupling regimeswere identified. (I) Starting from a weak interaction, the peak in the spectrum that ischaracteristic of the edge states initially shows a broadening and reduction in intensity.(II) With increasing interaction, the state begins to split into two peaks, so thatfrom dcri ≈ 15nm a double peak can be observed at both step edges. As the distancecontinues to decrease, the splitting reaches values of a few 10 meV, while the intensitycontinues to drop. (III) As soon as two step edges are separated by less than about 5nm, the spectra at the step edges converge against the spectrum over a terrace due tothe decreasing intensity and the decreasing energetic distance of the two peaks to thevan Hove singularities.iiiThe split is asymmetrical in areas I and II, which means that one peak remains roughlyat the original energy, while the other shifts further and further away with increasingcoupling. With regard to the asymmetry, no difference can be determined whether theconverging step edges form an island, a vacancy island or even run completely parallel.There is no preference as to whether the low energy or high energy peak shifts. Onlyin the regime of strong coupling (III) both peaks clearly leave the initial energy.In contrast to this, a considerable influence of the geometry on the spectrum can beobserved, with the included angle as parameter, for intersecting steps. Independentof the angle, there is no longer an edge state at the intersection itself. The statesat the four edges start to decay, depending on the angle, about 10-15nm before thepoint of intersection. Surprisingly, it turns out that in the case of right angled steps nosplitting at all can be observed, while a double peak can be found for all other angles.This discovery indicates orthogonality with respect to a quantum number in the edgestates involved. In addition to a theoretically predicted spin polarization, this effectcan also be caused by the orbital character of the Dirac cones involved.Since the topological protection in Pb1−xSnxSe is guaranteed by crystal symmetries,the last intrinsic effect to be examined is the influence of one dimensional defects onthe edge states. A near-surface defect, which cannot be classified in any more detailand a screw dislocation are taken into account. In both cases, a splitting of the edgestate into a double peak can also be shown.In the second part of this thesis the basis for reuse of surfaces in future experimentswith (magnetic) adatoms is created. The combination of sputtering and annealing notonly creates a cleaned surface, but in addition it tunes the Fermi level in a controllableway. This effect is based on a modification of the Sn concentration and the associatednumber of holes.Finally, the first measurements on Cu and Fe-doped samples are shown. The adatomscause n-doping, which shifts the Dirac point of the system in the direction of theFermi level. As soon as he has achieved this, there is an interaction phenomenon at thefreestanding step edges. This leads to a double peak structure with a fine split of a fewmeV. This phenomenon is limited to a narrow energy window in which the position ofthe Dirac point may only deviate by about 5 meV (in both directions) from that of theFermi level.
7

Nichtmagnetische Isolatoren in Hexagonalen Gittermodellen / Nonmagnetic insolatores in hexagonal lattice models

Laubach, Manuel January 2014 (has links) (PDF)
Wir untersuchen zunächst das Hubbard-Modell des anisotropen Dreiecksgitters als effektive Beschreibung der Mott-Phase in verschiedenen organischen Verbindungen mit dreieckiger Gitterstruktur. Um die Eigenschaften am absoluten Nullpunkt zu bestimmen benutzen wir die variationelle Cluster Näherung (engl. variational cluster approximation VCA) und erhalten das Phasendiagramm als Funktion der Anisotropie und der Wechselwirkungsstärke. Wir finden für schwache Wechselwirkung ein Metall. Für starke Wechselwirkung finden wir je nach Stärke der Anisotropie eine Néel oder eine 120◦-Néel antiferromagnetische Ordnung. In einem Bereich mittlerer Wechselwirkung entsteht in der Nähe des isotropen Dreiecksgitters ein nichtmagnetischer Isolator. Der Metall-Isolator-Übergang hängt maßgeblich von der Anisotropie ab, genauso wie die Art der magnetischen Ordnung und das Erscheinen und die Ausdehnung der nichtmagnetischen Isolatorphase. Spin-Bahn Kopplung ist der ausschlaggebende Parameter, der elektronische Bandmodelle in topologische Isolatoren wandelt. Spin-Bahn Kopplung im Allgemeinen beinhaltet auch den Rashba Term, der die SU(2) Symmetrie vollständig bricht. Sobald man auch Wechselwirkungen berücksichtigt, müssen sich viele theoretische Methoden auf die Analyse vereinfachter Modelle beschränken, die nur Spin-Bahn Kopplungen enthalten, welche die U(1) Symmetrie erhalten und damit eine Rashba Kopplung ausschließen. Wir versuchen diese bisher bestehende Lücke zu schließen und untersuchen das Kane-Mele Hubbard (KMH) Modell mit Rashba Spin-Bahn Kopplung und präsentieren eine systematische Analyse des Effekts der Rashba Spin-Bahn Kopplung in einem korrelierten zweidimensionalen topologischen Isolator. Wir wenden die VCA auf dieses Problem an und bestimmen das Phasendiagramm mit Wechselwirkung durch die Berechnung der lokalen Zustandsdichte, der Magnetisierung, der Einteilchenspektralfunktion und der Randzustände. Nach einer ausführlichen Auswertung des KMH-Modells, bei erhaltener U(1) Symmetrie, finden wir auch für endliche Wechselwirkung, dass eine zusätzliche Rashba Kopplung zu neuen elektronischen Phasen führt, wie eine metallische Phase und eine topologische Isolatorphase ohne Bandlücke in der lokalen Zustandsdichte, die aber eine direkte Bandlücke für jeden Wellenvektor besitzt. Für eine Klasse von 5d Übergangsmetallen untersuchen wir ein KMH ähnliches Modell mit multidirektionaler Spin-Bahn Kopplung, das wegen seiner Relevanz für die Natrium-Iridate (engl. sodium iridate) als SI Modell bezeichnet wird. Diese intrinsische Kopplung bricht die SU(2) Symmetrie bereits vollständig und dennoch erhält man wegen der speziellen Form für starke Wechselwirkung wieder einen rotationssymmetrischen Néel-AFM Isolator. Der topologische Isolator des SIH-Modells ist adiabatisch mit dem des KMH-Modells verbunden, jedoch sind die Randströme hier nicht mehr spinpolarisiert. Wir verallgemeinern das Konzept der Klein-Transformation, das bereits erfolgreich auf Spin-Hamiltonians angewandt wurde, und wenden es auf ein Hubbard-Modell mit rein imaginären spinabhängigen Hüpfen an, das im Grenzfall unendlicher Wechselwirkung in das Kitaev-Heisenberg Modell übergeht. Dadurch erhält man ein Modell des Dreiecksgitters mit reellen spinunabhängigen Hüpfen, das aber eine mehratomige Einheitszelle besitzt. Für schwache Wechselwirkung ist das System ein Dirac Halbmetall und für starke Wechselwirkung erhält man eine 120◦-Néel antiferromagnetische Ordnung. Für mittlere Wechselwirkung findet man aber einen relativ großen Bereich in dem eine nichtmagnetische Isolatorphase stabil ist. Unsere Ergebnisse deuten auf die mögliche Existenz einer Quanten Spinflüssigkeit hin. / We investigate the anisotropic triangular Hubbard model as a suggested effective description of the Mott phase in various triangular organic compounds. Employing the variational cluster approximation (VCA) to treat the zero temperature phasediagram as a function of anisotropy and interaction strength. The metal-insulator transition substantially depends on the anisotropy, so does the nature of magnetism and the emergence of a nonmagnetic insulating phase establishing a spin liquid candidate regime. For weak interactions we find a metal for all anisotropies. Depending on the strength of anisotropy we find a Néel- or a 120◦-Néel-AFM order in the limit of square and triangular lattice. The non-magnetic insulating phase is located around the isotropic triangular lattice for intermediate interaction strength and is bounded by the metallic phase to weaker interactions, the Néel-AFM insulator for less anisotropy and the 120◦-Néel-AFM insulator for stronger interaction strength [1]. Spin-orbit (SO) coupling is the crucial parameter to drive topological insulating phases in electronic band models. In particular, the generic emergence of SO coupling involves the Rashba term which fully breaks the SU(2) spin symmetry. As soon as interactions are taken into account, however, many theoretical studies have to content themselves with the analysis of a simplified U(1) conserving SO term without Rashba coupling. We intend to fill this gap by studying the Kane-Mele-Hubbard (KMH) model in the presence of Rashba SO coupling and present the first systematic analysis of the effect of Rashba SO coupling in a correlated two-dimensional topological insulator. We apply the VCAto determine the interacting phase diagram by computing local density of states, magnetization, single particle spectral function, and edge states. Preceded by a detailed VCAanalysis of the KMH model in the presence of U(1) conserving SO coupling, we find that the additional Rashba SO coupling drives new electronic phases such as a metallic regime and a direct-gap only topological insulating phase which persist in the presence of interactions [2]. In 5d transition-metal oxides, both the spin-orbit interaction and the electron correlation emerge at comparable orders of magnitude. In these systems, a variety of specifically tailored crystal structures are available, enabling the design of robust topological insulators. We study theoretically a monolayer of the 5d-compound Na2IrO3, modeled by a Hubbard-type of Hamiltonian on a honeycomb lattice where the spin symmetry is not conserved. Based on a VCAcalculation, the zero temperature phase diagram is obtained. We generalize the concept of Klein-dualities, successfully applied to spin Hamiltonians in the past, for tight-binding models and, as such, for Hubbard models. Specifically, we consider an imaginary spin-dependent hopping problem supplemented with an on-site Coulomb interaction which corresponds in the strong coupling limit to the Kitaev-Heisenberg model on the triangular lattice. After applying the Klein-transformation, we obtain a real and spin-independent model which we study in detail using the VCA. For weak interactions, the system is a Dirac semi-metal; for strong interactions, it acquires magnetic order being of 120◦-Néel type. For intermediate interactions, there is a large non-magnetic insulator phase. Our results point towards the possibility of a quantum spin liquid phase.
8

Entwicklung einer funktionellen 3D Magnetresonanz-Defäkographie / Development of a functional 3D magnetic resonance defecography

Ratz, Valentin January 2016 (has links) (PDF)
Epidemiologische Studien schätzen die Inzidenz chronischer Obstipation auf bis zu 27% der Gesamtbevölkerung. Betroffenen Patienten ist die Stuhlentleerung nicht oder nur unter großer Anstrengung und nicht selten nur unter Zuhilfenahme der Hand möglich. Häufig sind funktionelle Pathologien, welche sich nur während der Defäkation ausbilden, hierfür verantwortlich. Daher ist für die Diagnose und Evaluation dieser Pathologien ein bildgebendes Verfahren notwendig, welches die dynamische Darstellung der Defäkation ermöglicht. Der Goldstandard zur Untersuchung von Patienten mit funktionellen Beckenbodenstörungen ist die Entero-Colpo-Cysto-Defäkographie (ECCD). Diese Durchleuchtungsmethode erfordert die Applikation ionisierender Strahlung im Bereich des Beckens. Außerdem müssen für die Untersuchung Rektum und Vagina mit bariumhaltigem Kontrastmittel, der Dünndarm mit barium- und iodhaltigem Kontrastmittel und zusätzlich die Blase mit iodhaltigem Kontrastmittel gefüllt werden. Bei der MR-Defäkographie hingegen ist keine ionisierende Strahlung notwendig und nur eine rektale Füllung mit Ultraschallgel als Kontrastmittel erforderlich. Zudem ermöglichen statische Aufnahmen aufgrund des hohen Weichteilkontrasts der MR-Bildgebung eine detaillierte Darstellung des gesamten Beckenbodens. Die MR-Bildgebung ist jedoch im Vergleich zu anderen Bildgebungsmodalitäten, wie beispielsweise der radiographischen Durchleuchtung, langsam. Besonders zur Darstellung dynamischer Prozesse ist daher eine starke Beschleunigung des Akquisitionsprozesses notwendig. Bei der Standard 2D MR-Defäkographie wird für die Beschleunigung der Datenakquisition eine regelmäßige zweifache Unterabtastung des k-Raums vorgenommen. Hierdurch lassen sich aber nur drei räumlich voneinander getrennte 68 2D Schichten mit einer zeitlichen Aktualisierungsrate der drei Schichten von ca. 1s akquirieren. Dadurch ist aber besonders die Diagnose lateral lokalisierter Pathologien eingeschränkt oder gar nicht möglich. Daher wurde in dieser Arbeit eine 3D MR-Defäkographie zur dynamischen Darstellung der Defäkation innerhalb eines vollständigen 3D Volumens entwickelt, implementiert und anhand von 9 Patientenmessungen optimiert. Die letzten 4 Patienten wurden mit den optimierten Sequenzparametern untersucht. Ausgehend von der kartesischen Datenakquisition der bestehenden 2D MRDefäkographie wurden zunächst dreidimensionale kartesische Trajektorien zur Datenakquisition und dafür geeignete Algorithmen zur Datenrekonstruktion untersucht. In diesem Zusammenhang wurde ein GRAPPA Centric-Out Akquisitionsschema in Kombination mit einer GRAPPA Datenrekonstruktion vorgestellt. Es zeigte sich jedoch, dass eine Stack-of-Stars Trajektorie in Bezug auf die stabile, rauscharme, dynamische Darstellung der Defäkation, vorteilhaft gegenüber der untersuchten kartesischen GRAPPA Centric-Out Trajektorie ist. Zur weiteren Optimierung der Messsequenz wurden daher drei radiale Stackof-Stars Akquisitionsschemata untersucht: Das Standard Stack-of-Stars Schema sowie zwei mit View-Sharing und zwei unterschiedlichen Dichtegewichtungen modifizierte Stack-of-Stars Schemata (DW-Sampling 1 und DW-Sampling 2). Das View-Sharing ermöglicht durch die Umstellung der Reihenfolge der akquirierten Partitionen nahezu eine Verdopplung der rekonstruierten Zeitpunkte der dynamisch gemessenen Zeitserie. Die Dichtegewichtung bewirkt, dass in den zentralen Partitionen mehr radiale Speichen gemessen werden und damit das k-Raum Zentrum dichter abgetastet wird als in den äußeren Partitionen. Beim Dichtegewichtungsschema DW-Sampling 2 ist der Abfall der Anzahl der innerhalb einer Partition gemessenen Speichen stärker als beim DW-Sampling 1. Trotzdem führte das mit View-Sharing und DW-Sampling 2 modifizierte Stackof-Stars Akquisitionsschema in Verbindung mit der FISTA Compressed Sensing Datenrekonstruktion zum besten Kompromiss zwischen erreichbarer räumlicher 69 und zeitlicher Auflösung. Dieses optimierte Setup ermöglicht die dynamische Darstellung der Defäkation in 7 Schichten eines vollständigen 3D Volumens mit einer Volumenaktualisierungsrate von 1,3s. Im Vergleich zur standardmäßig durchgeführten 2D MR-Defäkographie ist daher eine mehr als doppelt so große Abdeckung mit einer vergleichbaren zeitlichen Aktualisierungsrate und einer etwas geringeren räumlichen Auflösung gewährleistet. Hierdurch lassen sich zusätzlich zu den gewöhnlichen zentral gelegenen Pathologien auch lateral ausgeprägte Pathologien besser abdecken und diagnostizieren. / Epidemiological studies estimated that the incidence of chronic obstructive diseases is up to 27% of the general population. Affected patients suffer from incomplete obstructed defecation and in many cases defecation is only possible with manual maneuvers. Functional pathologies that only arise during the defecation process are responsible for that. Therefore, for the diagnosis and evaluation of these pathologies an imaging technique is necessary, that allows to visualize the dynamic of the defecation process. The gold-standard to evaluate patients with functional pelvic floor disorders is the radiographic method of Entero-Colpo-Cysto Defecography (ECCD). Two major disadvantages of ECCD are the application of ionizing radiation in the pelvic floor region and the displeasing measurement procedure for the patients. Barium containing contrast agent has to be administered to rectum and vagina of the patient, barium and iodine containing contrast agents have to be administered to the small intestine and in addition the bladder has to be filled with iodine containing contrast agent. However MR-defecography uses no ionizing radiation and only requires a rectal filling with sonographic gel as contrast agent. In addition static MR images provide a detailed overview over the whole pelvic floor due to the high soft tissue contrast. But compared to other imaging modalities like ECCD MR imaging is slow and thus a high acceleration of the data acquisition is necessary to visualize the fast dynamic defecation process. In the standard 2D MR-defecography a regular twofold undersampling of the kspace is performed for acceleration. Hereby only 3 spatially separated 2D slices with a temporal update rate of about 1s can be acquired. Thus especially the detection of lateral localized pathologies is limited or even impossible. 72 Therefore, a 3D MR-defecography was developed, implemented and optimized by means of a study in 9 patients. The last 4 patients were investigated with the optimized parameters. Based on the Cartesian data acquisition of the standard 2D MR-defecography, 3D Cartesian trajectories for data acquisition and suitable algorithms for data reconstruction were evaluated. In this context a GRAPPA Centric-Out acquisition scheme in combination with a GRAPPA data reconstruction was presented. It turned out however, that a Stack-of-Stars trajectory is preferable to the proposed Cartesian GRAPPA Centric-Out trajectory in regard to a stable, low-noise and dynamic visualization of the defecation. Therefore, to further optimize the measurement sequence, three different Stackof-Stars data acquisition schemes were investigated: The standard Stack-ofStars scheme as well as the two with View-Sharing and Density-Weighting modified Stack-of-Stars schemes DW-Sampling 1 and DW-Sampling 2. ViewSharing allows to almost double the number of reconstructed time frames by changing the order of the acquired partitions. The Density-Weighting results in more radial spokes in the central partitions than in the outer partitions and thereby assures a denser sampling of the k-space center than in the kspace periphery. The undersampling factors in the outer partitions are higher in DW-Sampling 2 than in DW-Sampling 1. Nevertheless the Stack-of-Stars acquisition scheme modified with View-Sharing and DW-Sampling 2 in combination with a FISTA Compressed Sensing data reconstruction led to the best trade-off between achievable spatial and temporal resolution. This optimized setup allows the dynamic visualization of the defecation within 7 slices and a volume update rate of 1,3s. Compared to the standard 2D MR-defecography a more than doubled spatial coverage and a comparable temporal update rate are provided. This offers the possibility to cover and evaluate lateral localized pathologies additionally to the standard central localized pathologies.
9

Influence of Hot Carriers on Spin Diffusion in Gallium Arsenide / Über den Einfluss heißer Ladungsträger auf Spindiffusion in Galliumarsenid

Quast, Jan-Henrik January 2017 (has links) (PDF)
Since the late 20th century, spintroncis has become a very active field of research [ŽFS04]. The prospect of spin based information technology, featuring strongly decreased energy consumption and possibly quantum-computation capabilities, has fueled this interest. Standard materials, like bulk gallium arsenide (GaAs), have experienced new attention in this context by exhibiting extraordinarily long lifetimes for nonequilibrium spin information, which is an important requirement for efficient spin based information storage and transfer. Another important factor is the lengthscale over which spin information can be transported in a given material and the role of external influences. Both aspects have been studied experimentally with innovative optical methods since the late 1990s by the groups of D. D. AWSHALOM and S. A. CROOKER et al. [KA99, CS05, CFL+05]. Although the pioneering experimental approaches presented by these authors led to a variety of insights into spin propagation, some questions were raised as well. Most prominently, the classical Einstein relation, which connects the mobility and diffusivity of a given particle species, seemed to be violated for electron spins in a bulk semiconductor. In essence, nonequilibrium spins appeared to move (diffuse) faster than the electrons that actually carry the spin. However, this contradiction was masked by the fact, that the material of interest was n-type GaAs with a doping concentration directly at the transition between metallic and insulating behavior (MIT). In this regime, the electron mobility is difficult to determine experimentally. Consequently, it was not a priori obvious that the spin diffusion rates determined by the newly introduced optical methods were in contradiction with established electrical transport data. However, in an attempt to extend the available data of optical spin microscopy, another issue surfaced, concerning the mathematical drift-diffusion model that has been commonly used to evaluate lateral spin density measurements. Upon close investigation, this model appears to have a limited range of applicability, due to systematic discrepancies with the experimental data (chapter 4). These deviations are noticeable in original publications as well, and it is shown in the present work that they originate from the local heating of electrons in the process of optical spin pumping. Based on insights gained during the second half of the 20th century, it is recapitulated why conduction electrons are easily overheated at cryogenic temperatures. The main reason is the poor thermal coupling between electrons and the crystal lattice (chapter 3). Experiments in the present work showed that a significant thermal gradient exists in the conduction band under local optical excitation of electron–hole pairs. This information was used to develop a better mathematical model of spin diffusion, which allowed to derive the diffusivity of the undisturbed system, due to an effective consideration of electron overheating. In this way, spin diffusivities of n-GaAs were obtained as a function of temperature and doping density in the most interesting regime of the metal–insulator-transition. The experiments presented in this work were performed on a series of n-type bulk GaAs samples, which comprised the transition between metallic conductivity and electrical insulation at low temperatures. Local electron temperature gradients were measured by a hyperspectral photoluminescence imaging technique with subsequent evaluation of the electron–acceptor (e,A$^0$) line shape. The local density of nonequilibrium conduction electron spins was deduced from scanning magneto-optic Kerr effect microscopy. Numerical evaluations were performed using the finite elements method in combination with a least-squares fitting procedure. Chapter 1 provides an introduction to historical and recent research in the field of spintronics, as far as it is relevant for the understanding of the present work. Chapter 2 summarizes related physical concepts and experimental methods. Here, the main topics are semiconductor optics, relaxation of hot conduction electrons, and the dynamics of nonequilibrium electron spins in semiconductors. Chapter 3 discusses optical heating effects due to local laser excitation of electron–hole pairs. Experimental evaluations of the acceptor-bound-exciton triplet lines led to the conclusion that the crystal lattice is usually not overheated even at high excitation densities. Here, the heat is efficiently dissipated to the bath, due to the good thermal conductivity of the lattice. Furthermore, the heating of the lattice is inherently limited by the weak heat transfer from the electron system, which on the other hand is also the reason why conduction electrons are easily overheated at temperatures below ≈ 30 K. Spatio-spectral imaging of the electron–acceptor-luminescence line shape allowed to trace the thermal gradient within the conduction band under focused laser excitation. A heat-diffusion model was formulated, which reproduces the experimental electron-temperature trend nicely for low-doped GaAs samples of n- and p-type. For high-doped n-type GaAs samples, it could be shown that the lateral electron-temperature profile is well approximated by a Gaussian. This facilitated easy integration of hot electron influence into the mathematical model of spin diffusion. Chapter 4 deals with magneto-optical imaging of optically induced nonequilibrium conduction-electron spins in n-GaAs close to the MIT. First, the spectral dependence of the magneto-optic Kerr effect was examined in the vicinity of the fundamental band gap. Despite the marked differences among the investigated samples, the spectral shape of the Kerr rotation could be described in terms of a simple Lorentz-oscillator model in all cases. Based on this model, the linearity of the Kerr effect with respect to a nonequilibrium spin polarization is demonstrated, which is decisively important for further quantitative evaluations. Furthermore, chapter 4 presents an experimental survey of spin relaxation in n-GaAs at the MIT. Here, the dependence of the spin relaxation time on bath temperature and doping density was deduced from Hanle-MOKE measurements. While all observed trends agree with established literature, the presented results extend the current portfolio by adding a coherent set of data. Finally, diffusion of optically generated nonequilibrium conduction-electron spins was investigated by scanning MOKE microscopy. First, it is demonstrated that the standard diffusion model is inapplicable for data evaluation in certain situations. A systematic survey of the residual deviations between this model and the experimental data revealed that this situation unfortunately persisted in published works. Moreover, the temperature trend of the residual deviations suggests a close connection to the local overheating of conduction electrons. Consequently, a modified diffusion model was developed and evaluated, in order to compensate for the optical heating effect. From this model, much more reliable results were obtained, as compared to the standard diffusion model. Therefore, it was shown conclusively that the commonly reported anomalously large spin diffusivities were at least in parts caused by overheated conduction electrons. In addition to these new insights some experimental and technological enhancements were realized in the course of this work. First, the optical resolution of scanning MOKE microscopy was improved by implementing a novel scanning mechanism, which allows the application of a larger aperture objective than in the usual scheme. Secondly, imaging photoluminescence spectroscopy was employed for spatially resolved electron-temperature measurements. Here, two different implementations were developed: One for lattice-temperature measurements by acceptor–bound exciton luminescence and a second for conduction-electron temperature measurements via the analysis of the electron–acceptor luminescence line shape. It is shown in the present work that the originally stated anomalously high spin diffusivities were caused to a large extent by unwanted optical heating of the electron system. Although an efficient method was found to compensate for the influence of electron heating, it became also evident that the classical Einstein relation was nonetheless violated under the given experimental conditions. In this case however, it could be shown that this discrepancy did not originate from an experimental artifact, but was instead a manifestation of the fermionic nature of conduction electrons. / Seit dem späten 20. Jahrhundert hat sich die sogenannte Spintronik zu einem sehr aktiven Forschungsgebiet entwickelt [ŽFS04]. Die Aussichten auf eine Spin-basierte Informationsverarbeitung mit stark reduziertem Energieverbrauch und eventuell möglichen Quantenrechenfähigkeiten hat das Forschungsinteresse erheblich angeheizt. Standard-Halbleiter-Materialien wie Galliumarsenid (GaAs) erfuhren in diesem Zusammenhang neue Aufmerksamkeit auf Grund von außergewöhnlich langen Lebensdauern für Nichtgleichgewichts-Spins, welche eine wichtige Voraussetzung für eine effiziente Spin-basierte Speicherung und Übertragung von Informationen darstellt. Weitere wichtige Faktoren sind die Distanz über die Spin-Information in einem gegebenen Material transportiert werden kann sowie die Rolle von äußeren Einflüssen. Beide Aspekte wurden experimentell mit innovativen optischen Methoden seit den späten 1990er Jahren durch die Gruppen von D. D. AWSHALOM und S. A. CROOKER untersucht [KA99, CS05, CFL+05]. Obwohl diese zukunftsweisenden experimentellen Ansätze zu einer Vielzahl von Einsichten in die Ausbreitung und Dynamik von Nichtgleichgewichts-Spins führten, wurden auch einige Fragen aufgeworfen. Am deutlichsten fiel auf, dass die Einsteinsche Beziehung zwischen Mobilität und Diffusivität für Elektronenspins in einem Volumenhalbleiter verletzt zu sein scheint. Stark vereinfacht gesagt, scheinen Nichtgleichgewichts-Spins schneller zu diffundieren als sich die dazugehörigen Elektronen bewegen können. Dieser Widerspruch könnte allerdings auch daher stammen, dass das hier untersuchte Material n-Typ GaAs mit Dotier-Konzentrationen direkt am Metall-Isolator-Übergang war. In diesem Bereich ist die korrekte experimentelle Bestimmung der Elektronenbeweglichkeit aus praktischen Gründen schwierig. Folglich konnte nicht von vornherein der Schluss gezogen werden, dass die mit den neuen optischen Methoden bestimmten Spindiffusionsraten tatsächlich im Widerspruch zu etablierten elektrischen Transportdaten standen. Es gab somit keinen unmittelbaren Grund, die quantitativen Ergebnisse in Frage zu stellen. Bei dem Versuch, die Datenlage zur optischen Spin-Mikroskopie an GaAs systematisch zu erweitern, hat sich allerdings gezeigt, dass die mathematisch-numerische Drift-Diffusions-Analyse, die gemeinhin verwendet wurde um laterale Spindichte-Messungen auszuwerten, grundlegende Probleme aufweist. Eine genaue Analyse der Thematik hat ergeben, dass das verwendete Modell bei sehr tiefen Temperaturen nur bedingt anwendbar ist (Kapitel 4). Dies äußert sich zum Beispiel in den oben erwähnten Publikationen bereits durch deutlich sichtbare Abweichungen zwischen dem Modell und den experimentellen Daten. In der vorliegenden Arbeit wird gezeigt, dass diese Diskrepanzen durch eine lokale Überhitzung der Leitungsband-Elektronen hervorgerufen wird, wie sie bei optischen Band-Band-Anregungen kaum zu vermeiden ist. Mit Hilfe von Erkenntnissen aus der zweiten Hälfte des 20. Jahrhunderts wird rekapituliert, warum Leitungselektronen bei kryogenen Temperaturen durch optische Anregung extrem leicht überhitzt werden. Der Grund dafür ist die schlechte thermische Kopplung zwischen den Elektronen und dem Kristallgitter (Kapitel 3). Außerdem wird experimentell direkt gezeigt, dass unter lokaler optischer Anregung von Elektron–Loch-Paaren deutliche thermische Gradienten im Leitungsband entstehen. Die daraus gewonnenen Informationen werden anschließend verwendet, um das mathematische Diffusionsmodell für die Auswertung optischer Spin-Mikroskopie-Daten zu verbessern. Dies ermöglichte schließlich, die Diffusion von Nichtgleichgewichts-Spins im Leitungsband über einen weiten Temperatur- und Dotierdichtebereich am Metall-Isolator-Übergang zu untersuchen (Kapitel 4.4). Die in dieser Arbeit vorgestellten Experimente wurden an einer Reihe von n-Typ Volumen-GaAs Proben mit Dotierdichten zwischen 7 × 10$^15$cm$^−3$ und 7 × 10$^16$cm$^−3$ bei Badtemperaturen zwischen 5K und 40K durchgeführt. Die lokale Elektronentemperatur wurde mit Hilfe verschiedener bildgebender Methoden vermessen, die auf der Photolumineszenz-Messung des Elektron–Akzeptor-Übergangs (e, A$^0$) basieren. Ortsaufgelöste Spindichte-Messungen wurden mit Hilfe der abrasternden magneto-optischen Kerr-Mikroskopie vorgenommen. Die numerische Auswertung basiert größtenteils auf der Finite-Elemente-Methode in Kombination mit der iterativen Anpassung der Modelle durch die Minimierung der quadratischen Abweichung. Die Arbeit ist wie folgt strukturiert. Die Einleitung in Kapitel 1 fasst einige zurückliegende Forschungsergebnisse und Erkenntnisse zusammen, die für das Verständnis der vorliegenden Arbeit relevant sind. In Kapitel 2 werden anschließend grundlegende physikalische Konzepte erläutert, die für die nachfolgenden Erörterungen von Bedeutung sind. Insbesondere werden hier die Themen Halbleiter-Optik, Relaxation heißer Leitungselektronen und die dynamischen Eigenschaften von Nichtgleichgewichts-Elektronenspins in Halbleitern sowie die dazugehörigen experimentellen Methoden und Techniken diskutiert. Kapitel 3 thematisiert die Heizwirkung, die sich bei lokaler optischer Anregung von Elektron–Loch-Paaren ergibt. Experimentelle Untersuchungen der Photolumineszenz von Akzeptor-gebundenen Exzitonen führen zu dem Schluss, dass das Kristallgitter in der Regel nicht signifikant überhitzt wird. Dies gilt auch bei relativ hohen Anregungsdichten, da die eingetragene Wärme auf Grund der guten Wärmeleitfähigkeit des Gitters effizient im Kristall verteilt und zum Wärmebad abgeführt wird. Des Weiteren wird der Wärmeeintrag ins Gitter durch die schlechte thermische Kopplung der Elektronen zum Gitter beschränkt. Dies ist zugleich auch der Grund, warum die Leitungsband-Elektronen bei Temperaturen unterhalb von ca. 30K sehr leicht überhitzen können. Die räumlich-spektrale Abbildung der Photolumineszenz des Elektron–Akzeptor-Übergangs erlaubt es hier, den räumlichen Temperaturverlauf innerhalb des Leitungsbandes unter fokussierter Laseranregung sichtbar zu machen. Ein Wärmetransport-Modell wird formuliert, das bei niedrig dotierten GaAs Proben den experimentellen Verlauf der Elektronentemperatur gut wiedergibt. Bei hochdotierten Proben kann der räumliche Temperaturverlauf allerdings auch sehr gut durch eine Gauß-Kurve beschrieben werden. Diese Näherung hat den praktischen Vorteil, dass sie sich auf handhabbare Weise mit dem mathematisch Modell zur Beschreibung der Spindiffusion verbinden lässt. Kapitel 4 befasst sich mit magneto-optischer Bildgebung von optisch induzierten Nichtgleichgewichts-Leitungselektronen-Spins in n-Typ GaAs am Metall-Isolator-Übergang. Zuerst wird die spektrale Abhängigkeit des magneto-optischen Kerr-Effekts in der spektralen Umgebung der Fundamentalbandlücke untersucht. Es wird gezeigt, dass trotz der deutlichen Unterschiede zwischen den untersuchten Proben die spektrale Form in allen Fällen sehr gut mit einem einfachen Lorentz-Oszillator-Modell angenähert werden kann. Basierend auf diesem Modell wird die Linearität des Kerr-Effekts in Bezug auf den Grad der Spinpolarisation untersucht, was für eine quantitative Auswertungen von entscheidender Bedeutung ist. Des Weiteren wird in Kapitel 4 eine umfangreiche experimentelle Untersuchung von Spin-Relaxationszeiten in n-Typ GaAs am Metall-Isolator-Übergang vorgestellt. Dabei wurde die Abhängigkeit der Spinrelaxationszeit von der Badtemperatur und der Dotierungsdichte mit Hilfe von Hanle-MOKE Messungen ermittelt. Alle beobachteten Trends stimmen gut mit publizierten Daten überein, erweitern jedoch die vorhandene Datenlage erstmals um einen zusammenhängenden Datensatz, der einen großen Temperatur- und Dotierdichtebereich abdeckt. Zu guter Letzt wird die Diffusion von optisch erzeugten Nichtgleichgewichts-Leitungselektronen-Spins durch abrasternde MOKE-Mikroskopie untersucht. Hier wird erstmals gezeigt, dass das Standard-Diffusions-Modell in bestimmten Situationen nicht zur Auswertung verwendet werden kann. Eine systematische Übersicht über die Abweichungen zwischen diesem Modell und den experimentellen Daten zeigt, dass dies leider in einigen der oben erwähnten Veröffentlichungen der Fall ist. Des Weiteren deutet die Temperaturabhängigkeit der Abweichungen auf einen engen Zusammenhang zur lokalen Überhitzung der Leitungselektronen hin. Basierend darauf wird ein modifiziertes Diffusionsmodell vorgestellt, bei dem die Auswirkung der Elektronenüberhitzung berücksichtigt wird. Dieses Modell erweist sich als sehr viel zuverlässiger für die Ermittlung von Spindiffusionsraten, welche dadurch erstmals systematisch für einen großen Temperatur- und Dotierbereich erfasst werden konnten. Dies ist ein starkes Indiz dafür, dass die häufig beobachteten ungewöhnlich hohen Spindiffusionsraten zumindest teilweise auf die Überhitzung der Leitungselektronen zurückzuführen sind. Zusätzlich zu diesen neuen Erkenntnissen wurden im Zuge dieser Arbeit einige experimentelle und technologische Optimierungen entwickelt und realisiert. Zunächst wurde die optische Auflösung der Raster-MOKE-Mikroskopie durch die Implementierung einer neuen Raster-Methode verbessert. Des Weiteren wurden zwei verschiedene Arten der bildgebenden Photolumineszenz-Spektroskopie implementiert und optimiert, um ortsaufgelöste Messungen der Elektronen- und Gittertemperatur durchzuführen. In der vorliegenden Arbeit wird gezeigt, dass die oftmals angegeben sehr hohen Spindiffusionsraten zu einem großen Teil durch die Überhitzung des Elektronensystems verursacht werden. Obwohl eine effiziente Methode gefunden wurde, den Einfluss dieser Überhitzung mathematisch zu berücksichtigen, ist es dennoch offensichtlich, dass die klassische Einstein-Beziehung unter den gegebenen Versuchsbedingungen nicht immer erfüllt war. In diesem Fall kann jedoch argumentiert werden, dass die Ursache hierfür kein experimentelles Artefakt war, sondern eine Manifestation der fermionischen Natur der Leitungsbandelektronen.
10

Magnetization Reversal Processes of Nanostructure Arrays

Krone, Philipp 29 July 2011 (has links)
In the thesis at hand, different concepts of magnetic recording were investigated both from an experimental and theoretical point of view. On the one hand, micromagnetic simulations of bit patterned media were performed examining the influence of magnetic and geometrical parameters on the magnetization reversal mechanism of the bit array. In this regard, the recording concept called exchange coupled composite (ECC) media was applied in combination with bit patterned media (BPM). It was demonstrated that ECC/BPM is superior in terms of narrowing the SFD which is vital for the implementation of BPM as a recording scheme in magnetic data storage deviced. Moreover, the stability of the magnetic state was calculated for single nanomagnets using the nudged elastic band algorithm. It was found out that the magnetic and geometrical properties have a severe influence on both, the energy barrier for magnetization reversal and the magnetization reversal process of the single nanomagnets. On the other hand, experimental studies of granular CoCrPt:SiO2 films deposited on self-assembled arrays of SiO2 nanoparticles with a size from 10 nm to 330 nm have been carried out, showing a distinct size-dependence of the coercive field and remanent magnetization with changing nanoparticle size. Moreover, these films have been irradiated with Co+ ions with different fluences, resulting in a change of the magnetic properties of the films due to both a change of the intergranular exchange coupling of the film and a degredation of the magnetic layers at higher irradiation fluences.

Page generated in 0.4032 seconds