• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 13
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 403
  • 207
  • 59
  • 44
  • 44
  • 40
  • 36
  • 36
  • 34
  • 34
  • 31
  • 30
  • 28
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Visualizing defects in source code

Almeida, João Pedro Rodrigues de January 2012 (has links)
Trabalho de investigação desenvolvido na Cranfield University. School of Engineering / Tese de mestrado integrado. Engenharia Informática e Computação. Faculdade de Engenharia. Universidade do Porto. 2012
2

Influência de parâmetros de processo no surgimento de trincas de resfriamento em revestimentos cerâmicos produzidos pelo processo de biqueima /

Neves, Wenceslau Fernandes das January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T19:42:24Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T04:36:24Z : No. of bitstreams: 1 150633.pdf: 4162454 bytes, checksum: 345d302a9b4145ca3f85bc58663b308d (MD5)
3

Avaliação de aspectos de qualidade da madeira utilizando o ultra-som

Puccini, Carlos Teixeira 01 August 2018 (has links)
Orientador : Raquel Gonçalves / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-01T13:14:32Z (GMT). No. of bitstreams: 1 Puccini_CarlosTeixeira_D.pdf: 8241924 bytes, checksum: 9d772eea9d13489286bbc832ea22dcc7 (MD5) Previous issue date: 2002 / Doutorado
4

Avalia??o de defeitos resistivos de manufatura em SRAMs frente ao fen?meno de NBTI

Martins, Marco T?lio Gon?alves 27 May 2016 (has links)
Submitted by PPG Engenharia El?trica (engenharia.pg.eletrica@pucrs.br) on 2017-10-03T14:30:54Z No. of bitstreams: 1 dissertacao_Marco_tulio.pdf: 5515221 bytes, checksum: 0531f41d66bffa4a34ad4958a41c2d61 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-10-04T13:10:44Z (GMT) No. of bitstreams: 1 dissertacao_Marco_tulio.pdf: 5515221 bytes, checksum: 0531f41d66bffa4a34ad4958a41c2d61 (MD5) / Made available in DSpace on 2017-10-04T13:17:57Z (GMT). No. of bitstreams: 1 dissertacao_Marco_tulio.pdf: 5515221 bytes, checksum: 0531f41d66bffa4a34ad4958a41c2d61 (MD5) Previous issue date: 2016-05-27 / With advances in technology and miniaturization of CMOS, reliability during the life cycle of Integrated Circuit (IC) becomes a complex concern for critical applications. Miniaturization brings many benefits as high performance, power consumption and increase number of functions inside of IC. However, alongside with these, the benefits for increase of interconnections and density of such SoCs create new challenges for the industry. Moreover, a chip needs to store more and more information, resulting in the fact that SRAM occupy the greatest part of SoCs. Consequently, technology advances need to increase the transistor?s density, turnning them a critical concern for testing and reliability to be analysed after manufacturing, since it creates new types of defects. Defects during manufacture process, as well as Negative Bias Temperature Instability (NBTI), Hot Carrier Injection (HCI) and Electromagnetic Interference (EMI) phenomena represent important challenges that must be addressed at an early stages and over the IC?s life-time. In this context, understanding these phenomena and how they affect technologies below 65nm is essential to ensure reliability required for critical applications. In addition, another source of defects is related to process variations during manufacture. Such defects, like resistive-open and resistive-bridge, appear as the most incident. These defects occur due to small geometric changes in the cell, resulting in static and dynamic failures. Depending on the size of defect they can be considered as weak-defects, which do not result in faulty behaviour at logic level and are not sensitized in conventional manufacturing tests. Note that dynamic faults are considered most responsible for testescapes during manufacturing test. Another important phenomena that affects the reliability of ICs over time is NBTI, causing the aging of SRAMs. In this context, this work proposes to analyze the impact of NBTI in SRAM cells with weak resistive-open and resistive-bridge defects that can escape manufacturing tests due to their dynamic behaviour but, with aging, may become dynamic faults over time. / Com o avan?o tecnol?gico e a miniaturiza??o da tecnologia CMOS, garantir a confiabilidade durante a vida ?til de Circuitos Integrados (CI) tem se tornado um ponto extremamente complexo e importante para aplica??es consideradas cr?ticas. Muitos s?o os benef?cios que esses avan?os trouxeram, como aumento do desempenho, frequ?ncia de opera??o, CIs com capacidade para novas e mais complexas funcionalidades entre outros. Entretanto, com o aumento do n?mero de interconex?es e densidade dos System-on-chip (SoC) novos desafios surgiram e necessitam ser solucionados para que estes avan?os possam continuar. Avan?os tecnol?gicos possibilitaram a fabrica??o de componentes com uma maior densidade de transistores em uma pequena ?rea de sil?cio, tornando-se um ponto cr?tico para o teste e an?lise da confiabilidade ap?s sua fabrica??o, uma vez que esse processo de fabrica??o gera novos tipos de defeitos. Neste sentido, defeitos do tipo resistive-open e resistive-bridge aparecem como os mais prov?veis. Esses defeitos ocorrem devido a pequenas mudan?as geom?tricas das c?lulas e podem causar falhas est?ticas, bem como falhas din?micas. Da mesma forma, fen?menos como Negative Bias Temperature Instability (NBTI), Positive Bias Temperature Instability (PBTI), Hot Carrier Injection (HCI) e Electromagnetic Interference (EMI) representam importantes desafios que obrigatoriamente devem ser tratados desde a fase inicial de projeto de CIs, bem como durante toda a sua vida ?til. Assim, compreender esses fen?menos e como os mesmos afetam tecnologias abaixo de 65nm ? considerado fundamental a fim de garantir a confiabilidade exigida para aplica??es consideradas cr?ticas. Neste contexto, esse trabalho visa avaliar o impacto de defeitos resistivos do tipo resistiveopen e resistive-bridge nas c?lulas de mem?ria do tipo 6T, que passaram nos testes de manufatura, mas que, ao longo dos anos manifestaram falha devido a presen?a do fen?meno de NBTI. Esses defeitos foram modelados atrav?s da inser??o de resist?ncias em determinados pontos da c?lula de mem?ria. Foi observado que defeitos do tipo resistive-open e resistive-bridge quando presentes entre os inversores de uma c?lula de mem?ria e n?o detectados durante os testes de manufatura, resultaram em falha nas opera??es de leitura da c?lula ao longo dos anos quando na presen?a de NBTI. Essa falha apresenta-se inicialmente com um comportamento din?mico e, de acordo com o envelhecimento da c?lula, passa a comporta-se como est?tica. Essa situa??o compromete a confiabilidade da c?lula, uma vez que o tempo de vida estimado da c?lula ser? inferior ao projetado.
5

Uso atual de talidomida e defeitos congênitos no Brasil

Vianna, Fernanda Sales Luiz January 2008 (has links)
A tragédia da talidomida na década de 1960 resultou no nascimento de aproximadamente doze mil crianças em todo o mundo com uma grande diversidade de defeitos congênitos (DC), sendo os mais notáveis os defeitos de redução de membros (DRM) do tipo pré-axial e intercalar, principalmente a focomelia, que poderiam ou não estar associados a outras malformações. Após esse episódio, diversos sistemas de vigilância de DC foram criados em todo o mundo a fim de evitar novas tragédias e monitorar as freqüências dos DC ao longo dos anos; e os DRM passaram a ser considerados particularmente sensíveis a agentes teratogênicos. Atualmente sabe-se que a talidomida tem importantes propriedades imunomoduladoras e antiangiogênicas, que trazem benefícios terapêuticos para um grande número de doenças, entre elas doenças dermatológicas, crônico-degenerativas e cânceres. No Brasil, a talidomida está aprovada para o tratamento de poucas condições, como o eritema nodoso da hanseníase, reação relacionada a uma doença ainda muito prevalente no país. Embora existam restrições para prescrição e uso por mulheres em idade fértil, o surgimento de novos casos de embriopatia por talidomida (ET) em anos recentes no Brasil, indica a possibilidade de ocorrência de outros casos não diagnosticados. Nosso objetivo foi implementar um sistema de vigilância epidemiológica de defeitos de redução de membros dirigido fundamentalmente para identificação de casos de ET em nascimentos ocorridos em 33 hospitais do Brasil participantes do Estudo Colaborativo Latino Americano de Malformações Congênitas (ECLAMC), no período de março de 2007 a fevereiro de 2008. Para isso, as características epidemiológicas dos DRM foram avaliadas nos anos de 2000-2006 e foi estabelecido um fenótipo de DRM para vigilância de ET, o qual inclui os DRM pré-axias, intercalares, combinados e amelias, denominado DRMTALIDO. A freqüência de DRM no período base (2000-2006) para o Brasil foi de 8,59/10000 nascimentos (IC 95%: 7,50 – 9,80), estatisticamente superior quando comparada a todos os outros países participantes do ECLAMC (6,83/10000 nascimentos; IC 95%: 6,40 – 7,30). Os DRM mais freqüentemente observados, em ordem decrescente, no período base, foram: transverso, pré-axial, intercalar, pós-axial, casos com mais de um tipo de DRM (chamado de combinados) e DRM axiais. A freqüência de DRMTALIDO no período base foi de 3,57/10000 nascimentos (IC 95%: 2,90 – 4,40). Durante o ano de vigilância a freqüência de DRM avaliada foi de 10,17/10000 nascimentos (IC95%: 8,20 – 12,40). Os DRM mais freqüentemente visualizados seguiram o mesmo padrão do período base, embora os defeitos combinados tenham apresentado a segunda maior freqüência, seguindo a tendência observada em 2004-2006 no período base. Além disso, os DRM intercalares, que no período base apresentaram tendência ao crescimento, não seguiram esse comportamento no período de vigilância. A freqüência de DRMTALIDO durante o último ano foi de 4,55/10000 nascimentos (IC 95%: 3,30 – 6,10). A região Sudeste do Brasil obteve as maiores taxas de DRM, que são explicadas pelos altos índices de DC registrados nos hospitais de referência inseridos nessa região. A região Sul possui a menor freqüência para o período base. Ainda que os dados disponíveis para região Norte e Centro-oeste sejam muito pequenos, eles são essenciais para vigilância de ET, já que essas regiões representam os maiores focos de hanseníase no Brasil. Foram identificados três casos suspeitos de ET, dois no Nordeste e um no Sudeste. Embora não exista a confirmação materna de uso da talidomida, este é um número preocupante, já que o esperado para essa síndrome deveria ser zero. A avaliação dos DRM no período base nos forneceu dados para realizar a vigilância prospectivamente não só dos DRMTALIDO, mas também de todos os outros DRM, para todo o Brasil e para cada região separadamente. Essa é uma ferramenta importante para o monitoramento dos DRM ao longo dos anos, e pode identificar aumentos nas freqüências de DRM e indicar a possível presença de teratógenos. Os resultados aqui encontrados também possibilitam o estudo mais aprofundado na busca da etiologia dos DRM na América do Sul. / The thalidomide tragedy in the 1960s resulted in the birth of approximately twelve thousand children around the world with a wide range of congenital defects (CD), being the most notable limb reduction defects (LRD) preaxial and intercalary type, mainly phocomelia, which might or might not be associated with other malformations. After this episode, several surveillance systems for CD were created around the world in order to prevent further tragedies and to monitor the frequencies of CD over the years, and the LRD have been considered particularly sensitive to teratogenic agents. Currently it is known that thalidomide has significant antiangiogenic and immunomodulatory properties, which bring therapeutic benefits to a large number of diseases, including dermatological, chronic degenerative diseases and cancers. In Brazil, thalidomide is approved for the treatment of a few conditions, such as erythema nodosum leprosum, a reaction related to the disease still very prevalent in the country. Although there are restrictions on prescription and use by women of childbearing potential, the emergence of new cases of thalidomide embriopathy (TE) in recent years in Brazil, indicates the possibility of other cases not diagnosed. Our objective was to implement a system of epidemiological surveillance of limb reduction defects addressed primarily to identify possible cases of TE in births in 33 hospitals in Brazil participating of the Latin American Collaborative Study of Congenital Malformations (ECLAMC) in the period from March 2007 to February 2008. For this, the epidemiological characteristics of LRD were assessed in the years 2000- 2006 and it was established a phenotype of LRD for surveillance of TE, which includes preaxial, intercalary, combined LRD and amelia, called LRDTHALIDO. The frequency of LRD in the baseline period (2000-2006) for Brazil was 8.59/10,000 births (95% CI: 7.50 - 9.80), statistically higher than all other participating countries of the ECLAMC (6.83/10,000 births, 95% CI: 6.40 - 7.30). The most common LRD, in descending order, in the period studied were: transverse, preaxial, intercalary, postaxial, cases with more than one type of LRD (called combined) and axial LRD. The frequency of LRDTHALIDO in the period baseline was 3.57/10,000 births (95% CI: 2.90 - 4.40). During the year of the surveillance, the frequency of LRD was 10.17/10,000 births (95% CI: 8.20 - 12.40). The most frequently LRD observed followed the same pattern of the baseline period, although the defects combined have shown the second largest frequency, following the trend observed in 2004-2006. Moreover, intercalary LRD, that showed an increased tendency during baseline period, did not follow this behavior in the surveillance period. The frequency of LRDTHALIDO during the last year was 4.55/10,000 births (95% CI: 3.30 - 6.10). The Southeastern Brazil obtained the highest rates of LRD, which are explained by high rates of CD recorded in the hospitals of reference included in this region. The Southern region has the lowest frequency for baseline period. While the data available for North and Mid-west are very small, they are essential for monitoring of TE, as these regions represent the largest outbreaks of leprosy in Brazil. We identified three cases suspected of TE, two at Northeast region and one at the Southeast. Although there is no confirmation of maternal use of thalidomide, this is number is worrisome, since the expected for this syndrome should be zero. The evaluation of LRD in the baseline period provided data to carry out the surveillance of DRMTALIDO not only prospectively, but also for all other LRD, for all Brazil and for each region separately. This is an important tool for monitoring of LRD over the years and can identify increases in the frequencies of LRD, as an indication of possible presence of teratogens. The results found here also enable the further study in search of the etiology of LRD in South America.
6

Uso atual de talidomida e defeitos congênitos no Brasil

Vianna, Fernanda Sales Luiz January 2008 (has links)
A tragédia da talidomida na década de 1960 resultou no nascimento de aproximadamente doze mil crianças em todo o mundo com uma grande diversidade de defeitos congênitos (DC), sendo os mais notáveis os defeitos de redução de membros (DRM) do tipo pré-axial e intercalar, principalmente a focomelia, que poderiam ou não estar associados a outras malformações. Após esse episódio, diversos sistemas de vigilância de DC foram criados em todo o mundo a fim de evitar novas tragédias e monitorar as freqüências dos DC ao longo dos anos; e os DRM passaram a ser considerados particularmente sensíveis a agentes teratogênicos. Atualmente sabe-se que a talidomida tem importantes propriedades imunomoduladoras e antiangiogênicas, que trazem benefícios terapêuticos para um grande número de doenças, entre elas doenças dermatológicas, crônico-degenerativas e cânceres. No Brasil, a talidomida está aprovada para o tratamento de poucas condições, como o eritema nodoso da hanseníase, reação relacionada a uma doença ainda muito prevalente no país. Embora existam restrições para prescrição e uso por mulheres em idade fértil, o surgimento de novos casos de embriopatia por talidomida (ET) em anos recentes no Brasil, indica a possibilidade de ocorrência de outros casos não diagnosticados. Nosso objetivo foi implementar um sistema de vigilância epidemiológica de defeitos de redução de membros dirigido fundamentalmente para identificação de casos de ET em nascimentos ocorridos em 33 hospitais do Brasil participantes do Estudo Colaborativo Latino Americano de Malformações Congênitas (ECLAMC), no período de março de 2007 a fevereiro de 2008. Para isso, as características epidemiológicas dos DRM foram avaliadas nos anos de 2000-2006 e foi estabelecido um fenótipo de DRM para vigilância de ET, o qual inclui os DRM pré-axias, intercalares, combinados e amelias, denominado DRMTALIDO. A freqüência de DRM no período base (2000-2006) para o Brasil foi de 8,59/10000 nascimentos (IC 95%: 7,50 – 9,80), estatisticamente superior quando comparada a todos os outros países participantes do ECLAMC (6,83/10000 nascimentos; IC 95%: 6,40 – 7,30). Os DRM mais freqüentemente observados, em ordem decrescente, no período base, foram: transverso, pré-axial, intercalar, pós-axial, casos com mais de um tipo de DRM (chamado de combinados) e DRM axiais. A freqüência de DRMTALIDO no período base foi de 3,57/10000 nascimentos (IC 95%: 2,90 – 4,40). Durante o ano de vigilância a freqüência de DRM avaliada foi de 10,17/10000 nascimentos (IC95%: 8,20 – 12,40). Os DRM mais freqüentemente visualizados seguiram o mesmo padrão do período base, embora os defeitos combinados tenham apresentado a segunda maior freqüência, seguindo a tendência observada em 2004-2006 no período base. Além disso, os DRM intercalares, que no período base apresentaram tendência ao crescimento, não seguiram esse comportamento no período de vigilância. A freqüência de DRMTALIDO durante o último ano foi de 4,55/10000 nascimentos (IC 95%: 3,30 – 6,10). A região Sudeste do Brasil obteve as maiores taxas de DRM, que são explicadas pelos altos índices de DC registrados nos hospitais de referência inseridos nessa região. A região Sul possui a menor freqüência para o período base. Ainda que os dados disponíveis para região Norte e Centro-oeste sejam muito pequenos, eles são essenciais para vigilância de ET, já que essas regiões representam os maiores focos de hanseníase no Brasil. Foram identificados três casos suspeitos de ET, dois no Nordeste e um no Sudeste. Embora não exista a confirmação materna de uso da talidomida, este é um número preocupante, já que o esperado para essa síndrome deveria ser zero. A avaliação dos DRM no período base nos forneceu dados para realizar a vigilância prospectivamente não só dos DRMTALIDO, mas também de todos os outros DRM, para todo o Brasil e para cada região separadamente. Essa é uma ferramenta importante para o monitoramento dos DRM ao longo dos anos, e pode identificar aumentos nas freqüências de DRM e indicar a possível presença de teratógenos. Os resultados aqui encontrados também possibilitam o estudo mais aprofundado na busca da etiologia dos DRM na América do Sul. / The thalidomide tragedy in the 1960s resulted in the birth of approximately twelve thousand children around the world with a wide range of congenital defects (CD), being the most notable limb reduction defects (LRD) preaxial and intercalary type, mainly phocomelia, which might or might not be associated with other malformations. After this episode, several surveillance systems for CD were created around the world in order to prevent further tragedies and to monitor the frequencies of CD over the years, and the LRD have been considered particularly sensitive to teratogenic agents. Currently it is known that thalidomide has significant antiangiogenic and immunomodulatory properties, which bring therapeutic benefits to a large number of diseases, including dermatological, chronic degenerative diseases and cancers. In Brazil, thalidomide is approved for the treatment of a few conditions, such as erythema nodosum leprosum, a reaction related to the disease still very prevalent in the country. Although there are restrictions on prescription and use by women of childbearing potential, the emergence of new cases of thalidomide embriopathy (TE) in recent years in Brazil, indicates the possibility of other cases not diagnosed. Our objective was to implement a system of epidemiological surveillance of limb reduction defects addressed primarily to identify possible cases of TE in births in 33 hospitals in Brazil participating of the Latin American Collaborative Study of Congenital Malformations (ECLAMC) in the period from March 2007 to February 2008. For this, the epidemiological characteristics of LRD were assessed in the years 2000- 2006 and it was established a phenotype of LRD for surveillance of TE, which includes preaxial, intercalary, combined LRD and amelia, called LRDTHALIDO. The frequency of LRD in the baseline period (2000-2006) for Brazil was 8.59/10,000 births (95% CI: 7.50 - 9.80), statistically higher than all other participating countries of the ECLAMC (6.83/10,000 births, 95% CI: 6.40 - 7.30). The most common LRD, in descending order, in the period studied were: transverse, preaxial, intercalary, postaxial, cases with more than one type of LRD (called combined) and axial LRD. The frequency of LRDTHALIDO in the period baseline was 3.57/10,000 births (95% CI: 2.90 - 4.40). During the year of the surveillance, the frequency of LRD was 10.17/10,000 births (95% CI: 8.20 - 12.40). The most frequently LRD observed followed the same pattern of the baseline period, although the defects combined have shown the second largest frequency, following the trend observed in 2004-2006. Moreover, intercalary LRD, that showed an increased tendency during baseline period, did not follow this behavior in the surveillance period. The frequency of LRDTHALIDO during the last year was 4.55/10,000 births (95% CI: 3.30 - 6.10). The Southeastern Brazil obtained the highest rates of LRD, which are explained by high rates of CD recorded in the hospitals of reference included in this region. The Southern region has the lowest frequency for baseline period. While the data available for North and Mid-west are very small, they are essential for monitoring of TE, as these regions represent the largest outbreaks of leprosy in Brazil. We identified three cases suspected of TE, two at Northeast region and one at the Southeast. Although there is no confirmation of maternal use of thalidomide, this is number is worrisome, since the expected for this syndrome should be zero. The evaluation of LRD in the baseline period provided data to carry out the surveillance of DRMTALIDO not only prospectively, but also for all other LRD, for all Brazil and for each region separately. This is an important tool for monitoring of LRD over the years and can identify increases in the frequencies of LRD, as an indication of possible presence of teratogens. The results found here also enable the further study in search of the etiology of LRD in South America.
7

Análise da evolução de defeitos de superfície em trechos da malha rodoviária do Estado do Ceará / Analysis of evolution of surface defects in highway network excerpts of the State of Ceará

Pontes, Carlos André Melo 01 1900 (has links)
PONTES, C. A. M. Análise da evolução de defeitos de superfície em trechos da malha rodoviária do Estado do Ceará. 2012. 125 f. Dissertação (Mestrado em Engenharia de Transportes) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-12T14:47:43Z No. of bitstreams: 1 2012_dis_campontes.pdf: 12178438 bytes, checksum: 6c06ccca03cdce90b9c29e6ca426a8c9 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-14T14:23:58Z (GMT) No. of bitstreams: 1 2012_dis_campontes.pdf: 12178438 bytes, checksum: 6c06ccca03cdce90b9c29e6ca426a8c9 (MD5) / Made available in DSpace on 2012-09-14T14:23:58Z (GMT). No. of bitstreams: 1 2012_dis_campontes.pdf: 12178438 bytes, checksum: 6c06ccca03cdce90b9c29e6ca426a8c9 (MD5) Previous issue date: 2012-01 / Due to the large predominance of the transportation by highways in Brazil, it is necessary to control the actions related to maintenance and conservation of the roads. With this purpose, institutions make use of modern computational systems, such as the DER/CE, which uses the ISMA (Integrated System of Maintenance Administration). The referred system, using the subsystem PMS (Pavement Management System), has a large database related to the roads condition, filled with data provided by surveys that bring periodically up to date information of the state roads. These data are acquired by using methodologies defined by the technical staff of the DER/CE, based on the following normalized procedures: Visual Continuous Survey (LVC) and International Roughness Index Survey (IRI). The first one evaluates the comfort of the traffic rolling and the second registers the surface distresses of the roads. This research presents a comparative analysis between LVC and IRI data, evaluating the evolution of the distresses and the methodologies and equipments involved in the procedures. It is expected that, with the contribution of this research, the methodologies and road related data be analyzed considering the limitations of the equipments and procedures. / Devido à grande predominância do modal de transporte rodoviário no Brasil, se faz cada vez mais necessário um controle sobre as ações de manutenção e de conservação das rodovias. Para isso, muitos órgãos rodoviários adotam modernos sistemas informatizados, que é o caso do DER/CE, que utiliza o SIGMA (Sistema Integrado de Gestão da Manutenção). O sistema, através do subsistema SGP (Sistema de Gerência de Pavimentos), possui um vasto banco de dados relativos à condição das rodovias, que é alimentado com dados provenientes de levantamentos de campo, que trazem, periodicamente, informações atualizadas da condição das rodovias estaduais. Estes dados são adquiridos utilizando metodologias definidas pela equipe técnica do DER/CE, baseadas em procedimentos normalizados, sendo os principais: o levantamento de irregularidade longitudinal (IRI) e o Levantamento Visual Contínuo (LVC). O primeiro avalia o conforto ao rolamento e o segundo registra os defeitos de superfície das rodovias. Esta pesquisa apresenta uma análise comparativa entre dados de LVC e de IRI, avaliando a evolução das quantidades de defeitos e do IRI e as metodologias e os equipamentos envolvidos nos levantamentos. Apresenta, ainda, uma tentativa de compreensão da evolução dos parâmetros medidos pelo LVC ao longo de oito anos. Espera-se que, com a contribuição desta pesquisa, as metodologias e os dados relativos à condição das rodovias sejam analisados considerando as limitações encontradas e que sejam sempre adotados o equipamento e o procedimento mais apropriados.
8

Redução de variação de tonalidade e defeitos superficiais em placas cerâmicas utilizando o método de análise e solução de problemas (MASP)

Hilgemberg, Daniel January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2015. / Made available in DSpace on 2016-04-19T04:06:55Z (GMT). No. of bitstreams: 1 337902.pdf: 2854141 bytes, checksum: 5d6e5c9b355b40f334742fb5dc3faa5f (MD5) Previous issue date: 2015 / Em todos os ramos industriais existem inúmeras situações cotidianas que põem em risco a qualidade dos produtos que estão sendo fabricados. Com isso, há necessidade de uma atenção redobrada de diversas áreas da engenharia e produção para prever a ocorrência desses problemas, ou então, caso eles ocorram, deve-se encontrar rapidamente a solução dessas possíveis interferências no processo fabril. Porém, nem sempre as ações aplicadas conseguem atingir efetivamente a causa raiz do problema, pois caso a avaliação dessa interferência no processo produtivo for feita de maneira inadequada e mal planejada, esse problema irá se alongar por um tempo longo, gerando custos desnecessários. Para que seja feita uma melhor análise de potenciais problemas que atinjam o processo fabril será descrito neste trabalho o uso do Método de Análise e Solução de Problemas (MASP) na identificação e resolução de alguns temas relacionados à indústria de revestimentos cerâmicos. Primeiramente será descrito como funciona o método e como ele foi implementado na empresa estudada e, posteriormente, serão apresentados dois estudos de caso aplicados nessa mesma empresa com a utilização do MASP. O primeiro estudo de caso destaca como, aplicando-se o MASP, foi diminuída em 90% a geração de SKUs (Stock Keeping Units ou Unidade de Manutenção de Estoque) e tonalidades na produção de um determinado produto. O outro caso estudado refere-se a um tipo de contaminação que retrata um defeito na superfície do revestimento cerâmico, onde se obteve uma redução de 70% deste tipo de contaminante após a aplicação desta metodologia.<br> / Abstract : In all industries, there are countless everyday situations that endanger the quality of products being manufactured and thus, there is need for increased attention from various fields of engineering and production to predict the occurrence of those problems, but if they occur a solution to this potential problem in the production process should be found quickly. However, not always the applied actions can achieve effectively the root cause of the problem, since if the assessment of such problem in the production process is made in an inadequate manner and poorly planned, the problem will remain for a long time, resulting in additional costs. In order to perform a better analysis of potential problems that take place in the production process, in this work using the Method of Problem Analysis and Solving (MASP) will be applied in order to identify and solve some issues related to the ceramic tile industry. Initially it will be described how MASP functions, and its implementation at a company that manufactures ceramic tiles. Then, two case studies will be presented, which were applied at the company using MASP. The first case study highlights how the implementation of MASP contributed to a decrease of 90% in the production of SKUs (Stock Keeping Units), which was related to color tones in the production of a particular product. The second case study refers to a type of contamination that results from a defect on the surface of the ceramic tile, where a reduction of 70% of this type of contamination was achieved after the application of MASP.
9

Uso atual de talidomida e defeitos congênitos no Brasil

Vianna, Fernanda Sales Luiz January 2008 (has links)
A tragédia da talidomida na década de 1960 resultou no nascimento de aproximadamente doze mil crianças em todo o mundo com uma grande diversidade de defeitos congênitos (DC), sendo os mais notáveis os defeitos de redução de membros (DRM) do tipo pré-axial e intercalar, principalmente a focomelia, que poderiam ou não estar associados a outras malformações. Após esse episódio, diversos sistemas de vigilância de DC foram criados em todo o mundo a fim de evitar novas tragédias e monitorar as freqüências dos DC ao longo dos anos; e os DRM passaram a ser considerados particularmente sensíveis a agentes teratogênicos. Atualmente sabe-se que a talidomida tem importantes propriedades imunomoduladoras e antiangiogênicas, que trazem benefícios terapêuticos para um grande número de doenças, entre elas doenças dermatológicas, crônico-degenerativas e cânceres. No Brasil, a talidomida está aprovada para o tratamento de poucas condições, como o eritema nodoso da hanseníase, reação relacionada a uma doença ainda muito prevalente no país. Embora existam restrições para prescrição e uso por mulheres em idade fértil, o surgimento de novos casos de embriopatia por talidomida (ET) em anos recentes no Brasil, indica a possibilidade de ocorrência de outros casos não diagnosticados. Nosso objetivo foi implementar um sistema de vigilância epidemiológica de defeitos de redução de membros dirigido fundamentalmente para identificação de casos de ET em nascimentos ocorridos em 33 hospitais do Brasil participantes do Estudo Colaborativo Latino Americano de Malformações Congênitas (ECLAMC), no período de março de 2007 a fevereiro de 2008. Para isso, as características epidemiológicas dos DRM foram avaliadas nos anos de 2000-2006 e foi estabelecido um fenótipo de DRM para vigilância de ET, o qual inclui os DRM pré-axias, intercalares, combinados e amelias, denominado DRMTALIDO. A freqüência de DRM no período base (2000-2006) para o Brasil foi de 8,59/10000 nascimentos (IC 95%: 7,50 – 9,80), estatisticamente superior quando comparada a todos os outros países participantes do ECLAMC (6,83/10000 nascimentos; IC 95%: 6,40 – 7,30). Os DRM mais freqüentemente observados, em ordem decrescente, no período base, foram: transverso, pré-axial, intercalar, pós-axial, casos com mais de um tipo de DRM (chamado de combinados) e DRM axiais. A freqüência de DRMTALIDO no período base foi de 3,57/10000 nascimentos (IC 95%: 2,90 – 4,40). Durante o ano de vigilância a freqüência de DRM avaliada foi de 10,17/10000 nascimentos (IC95%: 8,20 – 12,40). Os DRM mais freqüentemente visualizados seguiram o mesmo padrão do período base, embora os defeitos combinados tenham apresentado a segunda maior freqüência, seguindo a tendência observada em 2004-2006 no período base. Além disso, os DRM intercalares, que no período base apresentaram tendência ao crescimento, não seguiram esse comportamento no período de vigilância. A freqüência de DRMTALIDO durante o último ano foi de 4,55/10000 nascimentos (IC 95%: 3,30 – 6,10). A região Sudeste do Brasil obteve as maiores taxas de DRM, que são explicadas pelos altos índices de DC registrados nos hospitais de referência inseridos nessa região. A região Sul possui a menor freqüência para o período base. Ainda que os dados disponíveis para região Norte e Centro-oeste sejam muito pequenos, eles são essenciais para vigilância de ET, já que essas regiões representam os maiores focos de hanseníase no Brasil. Foram identificados três casos suspeitos de ET, dois no Nordeste e um no Sudeste. Embora não exista a confirmação materna de uso da talidomida, este é um número preocupante, já que o esperado para essa síndrome deveria ser zero. A avaliação dos DRM no período base nos forneceu dados para realizar a vigilância prospectivamente não só dos DRMTALIDO, mas também de todos os outros DRM, para todo o Brasil e para cada região separadamente. Essa é uma ferramenta importante para o monitoramento dos DRM ao longo dos anos, e pode identificar aumentos nas freqüências de DRM e indicar a possível presença de teratógenos. Os resultados aqui encontrados também possibilitam o estudo mais aprofundado na busca da etiologia dos DRM na América do Sul. / The thalidomide tragedy in the 1960s resulted in the birth of approximately twelve thousand children around the world with a wide range of congenital defects (CD), being the most notable limb reduction defects (LRD) preaxial and intercalary type, mainly phocomelia, which might or might not be associated with other malformations. After this episode, several surveillance systems for CD were created around the world in order to prevent further tragedies and to monitor the frequencies of CD over the years, and the LRD have been considered particularly sensitive to teratogenic agents. Currently it is known that thalidomide has significant antiangiogenic and immunomodulatory properties, which bring therapeutic benefits to a large number of diseases, including dermatological, chronic degenerative diseases and cancers. In Brazil, thalidomide is approved for the treatment of a few conditions, such as erythema nodosum leprosum, a reaction related to the disease still very prevalent in the country. Although there are restrictions on prescription and use by women of childbearing potential, the emergence of new cases of thalidomide embriopathy (TE) in recent years in Brazil, indicates the possibility of other cases not diagnosed. Our objective was to implement a system of epidemiological surveillance of limb reduction defects addressed primarily to identify possible cases of TE in births in 33 hospitals in Brazil participating of the Latin American Collaborative Study of Congenital Malformations (ECLAMC) in the period from March 2007 to February 2008. For this, the epidemiological characteristics of LRD were assessed in the years 2000- 2006 and it was established a phenotype of LRD for surveillance of TE, which includes preaxial, intercalary, combined LRD and amelia, called LRDTHALIDO. The frequency of LRD in the baseline period (2000-2006) for Brazil was 8.59/10,000 births (95% CI: 7.50 - 9.80), statistically higher than all other participating countries of the ECLAMC (6.83/10,000 births, 95% CI: 6.40 - 7.30). The most common LRD, in descending order, in the period studied were: transverse, preaxial, intercalary, postaxial, cases with more than one type of LRD (called combined) and axial LRD. The frequency of LRDTHALIDO in the period baseline was 3.57/10,000 births (95% CI: 2.90 - 4.40). During the year of the surveillance, the frequency of LRD was 10.17/10,000 births (95% CI: 8.20 - 12.40). The most frequently LRD observed followed the same pattern of the baseline period, although the defects combined have shown the second largest frequency, following the trend observed in 2004-2006. Moreover, intercalary LRD, that showed an increased tendency during baseline period, did not follow this behavior in the surveillance period. The frequency of LRDTHALIDO during the last year was 4.55/10,000 births (95% CI: 3.30 - 6.10). The Southeastern Brazil obtained the highest rates of LRD, which are explained by high rates of CD recorded in the hospitals of reference included in this region. The Southern region has the lowest frequency for baseline period. While the data available for North and Mid-west are very small, they are essential for monitoring of TE, as these regions represent the largest outbreaks of leprosy in Brazil. We identified three cases suspected of TE, two at Northeast region and one at the Southeast. Although there is no confirmation of maternal use of thalidomide, this is number is worrisome, since the expected for this syndrome should be zero. The evaluation of LRD in the baseline period provided data to carry out the surveillance of DRMTALIDO not only prospectively, but also for all other LRD, for all Brazil and for each region separately. This is an important tool for monitoring of LRD over the years and can identify increases in the frequencies of LRD, as an indication of possible presence of teratogens. The results found here also enable the further study in search of the etiology of LRD in South America.
10

Caracterização de defeitos em semicondutores atraves de microscopia eletronica de varredura

Assumpção, Roberto de Toledo, 1954- 25 November 1988 (has links)
Orientador: Antonio Celso Fonseca de Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-17T23:02:42Z (GMT). No. of bitstreams: 1 Assumpcao_RobertodeToledo_D.pdf: 5023146 bytes, checksum: 32dc5ce9025ae42b702c7760c9b5c375 (MD5) Previous issue date: 1988 / Resumo: Este trabalho utiliza o Microscópio Eletrônico de Varredura (M.E.V) para o estudo de defeitos em materiais e dispositivos semicondutores. A operação do M.E.V. nos modos Catodoluminescência (CL) e coleção de carga ou EBIC (Electron Beam Induced Conductivity) permite caracterização precisa de dispositivos optoeletrônicos de GaAs/GaAlAs e também de células solares de Silício policristalino, tendo sido estabelecida uma correlação entra as etapas de fabricação e o desempenho final dos dispositivos de GaAs. Foi desenvolvido ainda um método de analise EBIC, denominado aqui EBIC-Quantitativo, aplicado para a obtenção de característica corrente-tensão I(v) de uma micro-região da amostra semicondutora iluminada pelo feixe de elétrons de M.E.V., de um modo análogo ao empregado na determinação da característica Fotovoltaica I(v) de células solares. Este método, associado aos demais modos de operação do M.E.V., possibilita o estudo das propriedades ópticas, elétricas e estruturais dos diversos defeitos presentes em semicondutores. / Abstract: The scanning Electron Microscope (S.E.M.) is an extremely versatile instrument wich can be applied for the characterization of a variety of materials, including metallic, ceramic and semiconductor specimens. I the latter case the energy band of semiconductor materials enables he operation of the instrument in the Cathodoluminescense (CL) and Electron Beam Induced Conductivity (EBIC) modes, providing a nondestructive method of examining semiconductors. Moreover, the EBIC and CL techniques are directly related to the electrical and optical properties of these materials. This work deals with the SEM-EBIC and CL characterization of defects of GaAs/GaAlAs optoelectronic devices and of polycrystalline Silicon solar cells. Defects such as dislocations, impurity and growth striations, compositional fluctuations and mechanical stresses at the interface of heterostructures (i.e. GaAs/GaAlAs and GaAs/SiO2) are qualitatively are quantitatively analysed. / Doutorado / Doutor em Engenharia Mecânica

Page generated in 0.0679 seconds