• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Compatibilidade biológica de materiais odontológicos no complexo dentina pulpar /

Benatti Neto, Carlos. January 2001 (has links)
Inclui dois anexos : A e B / Resumo: Não disponivel. / Abstract: Not available.
112

Efeito de tratamento de superfície na resistência de união de uma liga de Cobalto - Cromo e uma resina acrílica termicamente ativada /

Martinelli, Carolina da Silva Machado. January 2012 (has links)
Orientador: Estevão Tomomitsu Kimpara / Banca: Paulo Seraidarian / Banca: Rosilene Fernandes da Rocha / Resumo: A proposta deste estudo foi avaliar (1) a influência da rugosidade superficial e diferentes métodos de tratamento de superfície, na resistência de união da interface liga de Co-Cr/ RAAT; (2) a influência de diferentes métodos de envelhecimento na resistência de união da interface liga de Co-Cr/ RAAT, submetida a diferentes métodos de tratamento de superfície. Foram confeccionados 120 espécimes metálicos, em liga de Co-Cr. A superfície menor dos espécimes (Ø=7mm) foi regularizada e submetida a análise em M.O., rugosímetro e análise superficial qualitativa em MEV e quantificação de óxidos em EDS. Foi realizado o protocolo de jateamento (Al2O3), em sequência, análise em M.O., rugosímetro, MEV e EDS. Os espécimes foram divididos aleatoriamente em quatro grupos (n=30): C - controle; P - primer para metal; O - opaco cerâmico; PO - primer e opaco. Após inclusão em mufla os espécimes foram acrilizados em ciclo curto de polimerização. Após desinclusão os espécimes foram subdivididos em três grupos (n=10): armazenagem em água (A), ciclagem mecânica (CM) e ciclagem térmica (CT). Foi realizado o teste de resistência ao cisalhamento (100 Kgf - 0,5mm/min). Os resultados obtidos foram submetidos à analise estatística de alteração percentual e testes não paramétricos Kruskal-Wallis e Dunnet. Os postos médios obtidos foram: PA 103.75A; PT 99.70A; POA 86.150AB; OA 71.250ABC; OCT 77.50ABC; POCM 74.85ABC; OCM 70.55ABC; CA 44.70BCD; POCT 42.950BCD; PCM 25.60CD; CCT 14.50D; CCM 14.50D. A microrretenção mecânica não é um método efetivo para união liga de Co-Cr/ RAAT, sendo a abordagem combinada (jateamento + tratamento de superfície) mais eficiente implicando em melhores resultados de resistência de união para esta interface. Os métodos de envelhecimento influenciaram negativamente a resistência de união dos grupos C, P e PO / Abstract: The propose of this study was to (1) evaluate the influence of surface roughness and the different chemical treatment method for surface treatment in the shear bond strength on the interface for the Co-Cr alloy/ RAAT; (2) the influence of different aging methods in the shear bond strength on the interface for the Co-Cr alloy/RAAT, submitted to different methods of surface treatment. 120 specimens of Co-Cr were obtained. The smaller surface (Ø: 7 mm) was regularized and analyzed in optical microscopy (OP), roughness and MEV. The elements were quantified by EDS. The sandblasting protocol (Al2O3) was done followed by further MO, roughness, MEV and EDS analysis. The specimens were randomly divided into four groups (n = 30): C- control; P - metal primer; O - ceramic opaque; and PO - primer and opaque. After flask inclusion the specimens were acrilyzed in short polymerization cycle. The specimens were deflasked and subdivided in tree groups (n = 10): water storage (A), mechanical cycling (CM) and thermic cycling. Shear bond strength test (100 kgf - 0,5 mm/ min) was performed, and data were statistical analyzed with altered percentage, Kruskal-Wallis and Dunnet tests. The median values obtained were: PA 103.75A; PT 99.70A; POA 86.150AB; OA 71.250ABC; OCT 77.50ABC; POCM 74.85ABC; OCM 70.55ABC; CA 44.70BCD; POCT 42.950BCD; PCM 25.60CD; CCT 14.50D; CCM 14.50D. The mechanical micro-retention is not an effective method to union Co-Cr alloy/RAAT. Combined method (sandblasting + surface treatment) was the most efficient resulting in greatest values of shear bond strength. Aging methods negatively influenced in the bonding strength of the C, P and PO groups / Mestre
113

Avaliação clínica, ultra-estrutural e química de dentes que receberam selantes : estudo in vivo

Silva, Keyse Loyanne Batista da 16 December 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-03-21T12:11:21Z No. of bitstreams: 1 2013_KeyseLoyanneBatistadaSilva.pdf: 1498815 bytes, checksum: b5e788310e756f399f36c53338b51291 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-21T15:49:24Z (GMT) No. of bitstreams: 1 2013_KeyseLoyanneBatistadaSilva.pdf: 1498815 bytes, checksum: b5e788310e756f399f36c53338b51291 (MD5) / Made available in DSpace on 2014-03-21T15:49:24Z (GMT). No. of bitstreams: 1 2013_KeyseLoyanneBatistadaSilva.pdf: 1498815 bytes, checksum: b5e788310e756f399f36c53338b51291 (MD5) / O progresso científico na compreensão do processo carioso e o desenvolvimento dos materiais adesivos, possibilitou aos cirurgiões dentistas fazer mais que simplesmente remover tecido cariado. Este fato fez com que a principal preocupação dentro da odontologia nos últimos tempos tenha sido a pesquisa de meios e materiais que possam reduzir a ocorrência dessa enfermidade. Dentre as medidas mais utilizadas na prevenção da cárie em superfície oclusal está o selamento de fóssulas e fissuras. Neste contexto o objetivo deste estudo foi comparar a retenção clínica de selantes a base de ionômero de vidro e resina composta em fóssulas e fissuras de molares decíduos; avaliar a retenção dos dois materiais seladores por meio de microscopia eletrônica de varredura (MEV); bem como verificar os níveis de Cálcio (Ca), Fósforo (P) e Flúor (F) presentes no esmalte após a aplicação dos materiais. A presente pesquisa caracterizou um Ensaio Clinico Randomizado Split Mouth (boca dividida).Foram selecionadas 10 crianças com faixa etária entre 9 e 11 anos de idade, com indicação para aplicação de selantes em segundos molares inferiores decíduos. Os 20 dentes foram divididos em 2 grupos aleatórios, onde cada paciente recebeu o selante resinoso em um dente e o selante ionomérico no outro dente. Os espécimes foram submetidos a análise clínica e classificados quanto a presença do selante em: selante total, selante parcial e ausente, a mesma classificação foi utilizada para a análise por MEV. A medição dos elementos Ca, P e F foi realizada por meio da Espectometria de Energia Dispersiva (EDS). Os dados obtidos foram submetidos à análise estatística ao nível de significância de 5%. Os resultados relativos a avaliação clínica demonstraram que 100% dos selantes resinosos foram classificados como selante total, enquanto 40% dos selamentos com cimento de ionômero de vidro receberam a mesma classificação e 60% foram classificados como selante parcial. Contudo, a análise por MEV demonstrou que ambos os materiais apresentaram retenção semelhante à estrutura dentária (p=0,653). Com relação a troca iônica, verificou-se que os níveis dos íons Cálcio e Fósforo foram superiores no grupo Ionomérico com diferença significante entre os grupos (p=0,0136) e (p=0,0124) respectivamente. O estudo apresentou limitações para a aferição do íon Flúor. Os resultados demonstraram que o selante à base de cimento de ionômero de vidro mesmo após a perda parcial observada clinicamente, apresentou retenção semelhante ao material resinoso na análise por microscopia. Conclui-se que não houve diferenças estatísticas para avaliação da retenção entre os materiais estudados, mesmo após valores numericamente superiores de perda parcial observados clinicamente para o grupo ionomérico, sendo que os níveis dos íons Cálcio e Fósforo foram significativamente superiores neste grupo. ______________________________________________________________________________________ ABSTRACT / Scientific progress in understanding the carious process and the development of adhesive materials, enabled the dentists to do more than simply remove decayed tissue. This meant that the main concern in dentistry recently has been the research of means and materials that can reduce the occurrence of this disease. Among the most frequently used measures in prevention of caries in occlusal surface is the sealing of pits and fissures. Thus, the objective of this study was to compare the clinical retention of sealants based on glass ionomer and resin composite in pits and fissures of deciduous molars; to evaluate the retention of the two sealing materials by scanning electron microscopy (SEM), as well as checking levels Calcium (Ca), Phosphorus (P) and Fluoride (F) present in the enamel following application of the materials. This study featured a randomized clinical trial Split Mouth. Ten children with age between 9 and 11 years old , listed for application of sealants in deciduous lower second molars . The 20 teeth were divided into two random groups, where each patient received the resin sealant on one tooth and another tooth in glass ionomer sealant .The teeth were subjected to clinical examination and ranked as the presence of sealant: Sealant full, partial and missing sealant, the same classification was used for analysis by SEM. The measurement of calcium, phosphorus and fluoride elements was performed by through the EDS tool. Data were statistically analyzed at 5% significance level. The results of the clinical evaluation showed that 100% of resin sealants were classified as full sealant, while 40% of sealings with glass ionomer cement received the same rating and 60% were classified as partial sealant. However, analysis by scanning electron microscopy showed that both materials showed similar retention to tooth structure (p=0.653). Regarding to ion exchange, it was found that the levels of calcium and phosphorus ions were higher in the ionomer group with a significant difference between groups (p=0.0136) and (p=0.0124) respectively. The study presented limitations for the fluoride ion measurement. Results showed that the sealant based on glass ionomer cement even after the partial loss observed clinically, presented similar performance to resinous material by microscopy analysis of retention. It was concluded that there were no statistical differences for retention evaluation of the materials studied , even after numerically higher values of partial loss observed clinically for the ionomer group , and the levels of calcium and phosphorus ions were significantly higher in this group.
114

Avaliação da resposta tecidual frente aos cimentos MTA e MBPc. Análise microscópica de implantes realizados em alvéolos dentários de ratos / EVALUATION OF THE TISSUE RESPONSE TO MTA AND MBPC. MICROSCOPIC ANALISIS OF IMPLANTS IN ALVEOLAR BONE OF RATS.

Luciano Tavares Angelo Cintra 25 February 2005 (has links)
Este trabalho teve como objetivo avaliar quantitativa e qualitativamente a resposta inflamatória e a formação óssea frente ao implante de tubos de polietileno contendo o cimento experimental, MBPc, que contém o hidróxido de cálcio, desenvolvido pelos Profs. MORAES e BERBERT da disciplina de Endodontia da Faculdade de Odontologia de Bauru – USP, comparando-o ao cimento ProRoot MTA. Foram utilizados 48 ratos, divididos em três grupos. No grupo I, foram introduzidos no alvéolo dentário pós-extração tubos de polietileno vazios que serviram de controle para os grupos experimentais. No grupo II foram implantados tubos contendo o cimento ProRoot MTA e no grupo III o cimento experimental MBPc. Após 7, 15 e 30 dias do implante os animais foram mortos e as hemimaxilas direitas que continham os alvéolos e os tubos implantados foram removidas e processadas em laboratório para a análise em microscopia de luz. Os resultados demonstraram que ambos materiais têm comportamento biológico semelhante. Os valores obtidos por meio da avaliação por escores, quando submetidos ao teste de Mann-Whitney, cujo nível de significância adotado foi de 5%, não apresentaram diferenças estatisticamente significante entre os materiais. / The aim of this work was to evaluate in a quantitative and qualitative manner the inflammatory response and the bone formation after the implantation of tubes filled with the experimental sealer, MBPc, which has calcium hidroxide and was developed by Professors Moraes and Berbert (Endodontic Department – Bauru Dentistry College – USP) comparatively to ProRoot MTA. It was used 48 rats, which were divided in three groups. In the group I, empty polietilene tubes were inserted into the alveolar bone imediatelly after extraction, which were used as control. In the group II and group III, polietilene tubes filled with ProRoot MTA and MBPc were implanted respectivelly. After 7, 15 and 30 days after the implantation, the animals were sacrificed and the right hemi-maxilas, which had the alveolar bone with the tubes implanted, were removed and prepared for ligth microscopic analisis. The results showed that both materials had similar biological response. The scores obtained and submitted to Mann-Whitney statistical test (5%) did not showed significant differences between the materials.
115

Influencia da refusão de uma liga de niquel-cromo na adaptação cervical e interna de coroas totais com diferentes configurações marginais / Influence of the recast and different marginal configurations in the cervical and interior adaptation of Ni-Cr alloy total metallic crowns

Fernandes, Daniela Rodrigues 04 August 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T20:49:18Z (GMT). No. of bitstreams: 1 Fernandes_DanielaRodrigues_D.pdf: 2902457 bytes, checksum: 3296ab64fe21504cb62f4540283146c3 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste trabalho foi verificar a influência da fonte de calor na fusibilidade e dureza de uma liga comercial à base de Ni-Cr (VERA BOND 11) nova, refundida (100%) e nova acrescida de sobras (50%). Para análise da fusibilidade foram confeccionadas 10 amostras para cada condição de liga, com uma tela para peneira de poliéster, com 11 X 11 filamentos de 0,22 mm de espessura, perfazendo uma malha de 100 espaços quadrados fixada bilateralmente por toda a extensão em fios de cera de 2,5 mm, contendo um pino formador do canal de alimentação no vértice. Para análise da dureza foram confeccionadas pastilhas em cera azul regular, com 8,0 mm de diâmetro por 2,0 mm de espessura, unidas a um pino formador do canal de alimentação. Após a obtenção dos padrões, estes foram fixados à base formadora do cadinho, de forma que a distância da base à câmara de reserva fosse 0,5 cm. Uma solução redutora da tensão de superfície foi aplicada sobre o padrão e após a secagem, este foi incluído em revestimento fosfatado - Termocast (Polidental, São Paulo Brasil) manipulado a vácuo, seguindo as instruções do fabricante quanto a proporção e tempo de manipulação. Os anéis foram aquecidos em forno elétrico (EDG) até atingirem a temperatura de 900°C, quando foram preenchidos por aproximadamente 15 gramas de liga fundida pela fonte de calor maçarico de fusibilidade, com o auxílio de um microscópio comparador com aumento de 16 X, considerando o número de espaços preenchidos no molde pela liga. Para análise da dureza superficial Rockwell 30T, os corpos-de-prova foram incluídos em resina acrílica quimicamente ativada, polidos e levados ao aparelho de dureza Testor HTI Super-Panambra, onde foram realizadas as medidas e obtidas as médias. Os resultados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey, em nível de significância de 5%. Quando foram comparadas as fontes de calor com os diferentes tipos de liga houve diferença estatística significativa entre as fontes de calor, na qual o aquecimento por indução demonstrou melhores resultados para fusibilidade. Não houve diferença estatística significativa nos valores médios de dureza quando foi utilizada a fonte de calor maçarico e aquecimento por indução para as ligas virgem e mista, porém o aquecimento por indução demonstrou melhores resultados que o maçarico, diferindo estatisticamente os valores de dureza, quando da utilização da liga refundida / Abstract: The aim of the present study was to verify the influence of the heat source on the castability and hardness of a Ni-Cr-based commercial alloy ¿ VERA BONO II - in three different conditions: new (first use), recast, and new mixed with scraps. In order to evaluate castability, 10 specimens were made for each alloy condition, using a polyester sieve with 11x11 filaments, 0.22mm thick, resulting in a screen with 100 square spaces. This screen was fixed to 0.25mm threads along the extension of two sides, and a post was fixed to its vertex. In order to perform hardness analysis, circular specimens made of regular blue wax measuring 8.0 mm in diameter and 2.0 mm thick were connected to the post, forming the sprue. The patterns were then fixed to the casting chamber, so that the distance from the base to the reservoir was 0.5 cm. A surface tension-reducing solution was abundantly applied to the patterns and after drying, the patterns were embedded into a phosphate-bonded investment - Termocast (Polidental, São Paulo, Brazil) manipulated under vacuum pressure, following manufacturer's instructions regarding proportions and manipulation times. Casting rings were placed in an electric oven (Bravac) until the temperature of 900°C was reached, and were then filled with approximately 15 grams of alloy, molten either by an oxigen/acethylen gas torch or by induction as heat sources. Following this procedure, castability evaluate hardness Rockwell 30T, specimens were embedded in chemically activated acrylic resin and then placed on a Testor HTI Super-Panambra hardness teste r. Hardness values for each specimen were obtained, and the average hardness was calculated. Results were submitted to analysis of variance and averages were compared by Tukey's test at 5% probability. There were statistically significant differences between the heat sources applied to the different types of alloy, with induction presenting the best castability results. There were no statistically significant differences in the average hardness values between torch or induction as the heating source for new and mixed alloys, although induction showed the best results, leading to statistically significant differences in hardness, when recast alloy was used. / Doutorado / Doutor em Materiais Dentários
116

Avaliação retrospectiva de oito anos dos procedimentos implantodonticos associados ou não a procedimentos reconstrutivos realizados na area de cirurgia buco-maxilo-facial da Faculdade de Odontologia de Piracicaba

Stabile, Glaykon Alex Vitti 22 February 2006 (has links)
Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T13:20:28Z (GMT). No. of bitstreams: 1 Stabile_GlaykonAlexVitti_M.pdf: 2525293 bytes, checksum: aadb026ad284ab6fa320ca3a2895af56 (MD5) Previous issue date: 2006 / Resumo: O objetivo deste estudo foi realizar por meio de um levantamento retrospectivo de oito anos um delineamento do perfil da implantodontia dentro da Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba (FOP-Unicamp). Foram revisados ao todo 1422 prontuários cujos pacientes deveriam ser submetidos a procedimentos reabilitadores através da instalação de implantes dentários endósseos osseointegráveis. Os pacientes em questão foram caracterizados quanto à cor, gênero, idade, história médica pregressa, vícios e queixa principal. Os procedimentos realizados foram divididos em: procedimentos reconstrutivos (distração osteogênica, lateralização do nervo alveolar inferior, enxertos ósseos autógenos, enxertos ósseos heterógenos e levantamento de seio maxilar), sendo qualificados quanto ao momento de execução (previamente à instalação de implantes, de modo concomitante, ou ainda posteriormente a estes), região dos maxilares que foram reconstruídas por meio destes procedimentos e materiais utilizados, ou ainda procedimentos implantodônticos (número, dimensões, propriedades e região de instalação dos implantes dentários). Do universo analisado 732 prontuários obedeceram os critérios de inclusão. Desses, 65,16% eram do gênero feminino, com prevalência de pacientes na quinta década de vida; 21,31% relataram alterações sistêmicas e 19,26% dos pacientes utilizavam medicação de uso contínuo. O motivo que mais levou os pacientes a buscar um tratamento reabilitador através de implantes dentários foi a ausência dentária em 33,33% dos casos. Procedimentos reconstrutivos foram empregados em 38,52% dos pacientes, sendo esses: 15 distrações osteogênicas; 6 lateralizações do nervo alveolar inferior, 256 enxertos ósseos autógenos, 31 enxertos ósseos heterógenos e 72 pacientes receberam elevações de seio maxilar. Foram instalados 1649 implantes, perfazendo uma média de 2,25 implantes por paciente sendo a região anterior de maxila a mais reabilitada com 29,29% dos implantes instalados. Ao todo 62 implantes (3,75%) foram classificados como perdas primárias, sendo que a proporção de implantes perdidos em áreas reconstruídas ou em osso nativo foi semelhante (3,86% e 3,72% respectivamente). Como conclusão observamos que o perfil da população atendida no serviço em questão é principalmente de indivíduos da cor branca, gênero feminino e idade média de 42 anos, com queixa de ausência de um ou mais elementos dentários. Os procedimentos reconstrutivos foram em sua maioria enxertos ósseos autógenos de sítios doadores intrabucais realizados previamente à instalação de implantes dentários e que a taxa de perdas primárias entre implantes instalados em osso reconstruído e em osso nativo é bastante semelhante / Abstract: The aim of this study was to perform, through an eight-year retrospective survey, the identification of the characteristics of implantology in the Oral and Maxillofacial Surgery area of Piracicaba Dental School (FOP ¿ Unicamp). A total number of 1422 files of patients who should receive endosseous dental implants were reviewed. Patients were characterized as to color, gender, previous medical history, addictions and main complaint. The performed procedures were divided into: reconstructive procedures (distraction osteogenesis, inferior alveolar nerve lateralization, autogenous bone grafts, heterogenous bone grafts and maxillary sinus lift), according to the time of reconstruction (previously to implant installation, in the same surgical time or after implant placement), reconstructed regions and used materials, or implantodontic procedures (number, dimensions, properties and implant placement regions). From the analyzed data, 732 files met the inclusion criteria. Of the included files, 65.15% were female patients, and the fifth decade of age was the most prevalent; 21.31% reported systemic alterations, and 19.26% of the patients were taking continuous use medications. The most frequent reason for seeking rehabilitation with dental implants was dental absence (33.33% of the cases). Reconstructive procedures were performed in 38.52% of the patients: 15 cases of distraction osteogenesis; 6 lateralizations of the inferior alveolar nerve; 256 autogenous bone grafts; 31 heterogenous bone grafts and 72 patients who received maxillary sinus lifts. A total number of 1649 implants were placed, with a mean of 2.25 implants per patient, and the anterior maxilla was the most frequently rehabilitated region, with 29.29% of the implants. Early loss affected 62 implants (3.75%), and the percentage of lost implants in reconstructed or native bone areas was similar (3.86% and 3.72% respectively). As a conclusion, it was observed that the profile of the population treated in the service is manly female, white patients, with a mean age of 42 years-old and with a complaint of absence of one or more teeth. The most frequent reconstructive procedures were autogenous bone grafts from intraoral donor sites performed prior to the installation of dental implants, and the early loss in reconstructed and native bone regions is very similar / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
117

Avaliação da dureza Knoop e da resistencia de união de restaurações em composito apos diferentes protocolos de fotoativação / Knoop hardness and bond strength evaluation of composite restorations after different photoactivation protocols

Dall'Magro, Eduardo 19 July 2006 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T22:45:08Z (GMT). No. of bitstreams: 1 Dall'Magro_Eduardo_D.pdf: 295929 bytes, checksum: fff79306c903b7754412f722f45d554b (MD5) Previous issue date: 2006 / Resumo: Este estudo apresenta três experimentos na mesma linha de pesquisa. No primeiro estudo, foi avaliada a resistência de união através do método push out e a dureza Knoop do compósito dental Z250 (3MIESPE) fotoativado utilizando o aparelho de lâmpada halógena XL2500 (3M/ESPE) sob diferentes protocolos de fotoativação: modo contínuo (CH) (700 mW/cm2) por 20 segundos; modo contínuo de baixa intensidade (CL) (150 mW/cm2) por 20 segundos; e, pulse-delay com ativação na intensidade de 150 mW/cm2 por 2s(P2), 3s(P3), 5s(P5), 1 Os(P1 O) ou 15 segundos (P15), seguindo-se 1 minuto de espera, e complementado por 700 mW/cm2 por mais 20 segundos. Para o teste de push out, após a fotoativação, os corpos-de-prova foram armazenados a 37°C :I: 1 por 24h :t 1 até serem desgastados e polidos, e, os valores de resistência à união foram observados numa máquina de ensaio universal (Instron) com célula de carga de 500 N e velocidade de 0,5 mm/min. Para o ensaio de dureza, a fotoativação seguiu o mesmo protocolo. Após a confecção, as amostras foram embutidas em resina de poliestireno e submetidas ao acabamento e polimento com lixas d'água, a fim de obter as medidas de dureza, na superfície, a 1 mm, 2, 3, 4, e 5 mm de profundidade, num durometro (HMV 2, Shimadzu), utilizando carga de 50g, por 15 segundos. Os dados foram submetidos à Análise de Variância e as médias ao teste de Tukey (5%). Os resultados de resistência à união mostraram que o grupo P5, apresentou valor de resistência de união significantemente maior que os demais grupos. O grupo CL apresentou resistência de união menor que o grupo anteriormente citado, mas superior aos demais grupos. Não houve diferença estatística significativa entre os grupos P2, P3, P10, P15 e CH. A dureza Knoop mostrou que os grupos CH e P15 apresentaram as maiores médias de dureza na superfície e até 4 mm de profundidade. Os corpos-de-prova do grupo CL apresentaram as menores médias de dureza. Na profundidade de 3 mm , a dureza Knoop de todos os grupos foi estatisticamente inferior a da superfície. O segundo experimento avaliou a resistência de união através do método de push out e a dureza Knoop do compósito odontológico Z250 (3M/ESPE), fotoativado com o aparelho de lâmpada halógena XL2500 (3MIESPE), utilizando diferentes protocolos de fotoativação: modo contínuo (700 mW/cm2 por 20s) (CO); soft-staft (50 mW/crn2 por 5s, seguido por 700 mW/crn2 for 15s) (551); soft-start (100 mW/crn2 por 5s, seguido por 700 mW/cm2 por 15s) (552); soft-start (150 mW/crn2 por 5s, seguido por 700 mW/crn2 por 15s) (553); soft-start (200 mW/crn2 por 5s, seguido por 700 mW/cm2 por 15s) (554); soft-start (250 mW/cm2 por 5s, seguido por 700 mW/cm2 por 15s) (555); soft-start (300 mW/crn2 por 5s, seguido por 700 mW/crn2 por 15s) (556). Os testes de push out e de dureza Knoop foram realizados como no primeiro experimento. Os dados foram submetidos à Análise de Variância e as médias ao teste de Tukey (5%). Os resultados mostraram que o grupo 553, obteve a maior resistência de união quando comparado ao grupos. Não houve diferença estatística entre os outros modos soft-start em relação aos demais grupos. Os outros resultados de dureza, não apresentaram diferença estatística entre os grupos na região de superfície e até 4 mm de profundidade. Também foi observado que para cada grupo, não houve diferença estatística entre a região de superfície até a profundidade de 2 mm. O terceiro experimento avaliou a resistência de união através do método de push out do compósito odontológico Z250 (3M/E5PE), fotoativado com o aparelho de lâmpada halógena XL2500 (3MIE5PE), utilizando diferentes protocolos de fotoativação: soft-start (ativação na intensidade de 150 mW/crn2 por 2s(552), 3s(553), 5s(555), 10s(5510) ou 15 segundos (5515), e complementado por 700 mW/cm2 por mais 15 segundos); pulse-delay (ativação na intensidade de 150 mW/cm2 por 2s(P2), 3s(P3), 5s(P5), 1 Os(P1 O) ou 15 segundos (P15), seguindo-se 1 minuto de espera, e complementado por 700 mW/crn2 por mais 15 segundos). Os testes de push out foram realizados como no primeiro experimento. Os dados foram submetidos à Análise de Variância e as médias ao teste de Tukey (5%). Os resultados mostraram que não houve diferença estatística entre os modos soft-start. Para o modo pulse-delay, o grupo P5 apresentou resistência de união estatisticamente superior aos demais grupos. Os grupos fotoativados pelo modo pulse-delay apresentaram resistência de união superior comparados aos grupos fotoativados pelo modo soft-start / Abstract: This study showed three experiments in the same research line. The first study has assessed the bond resistance through the push out method and the Knoop hardness of the dental composite Z250 (3M/ESPE). photoactivated with the equipment of halogen light XL2500 (3M/ESPE), using different protocols of photoactivation: the continuous mode of high intensity (CH) (700mW/cm2) for 20 seconds; the continuos mode of low intensity (CL) (150mW/cm2) for 20 seconds; and the pulse-cJe/ay with 150mW/cm2 for 2s(P2), 3s(P3), 5s(P5), 10s(P10) or 15 seconds (P15), with a 1-minute delay, followed by 700mW/cm2 for 20 seconds. For the push out test, the test specimens were stored at 31> C :I: 1 for 24h :I: 1 until they were ground and polished, and, the bond strength values were observed through a universal test machine (Instron) with a charge cell of 500N and the speed of 0.5 mm/min. For the Knoop hardness, the specimens were made by using the same photoactivation protocols. After, the specimens were embedded in polyestiren resin and sanded and polished in order to obtain the hardness measures on top, 1 mm, 2, 3, 4, and 5 mm deep in a hardness measure machine (HMV 2, Shimadzu), using a charge of 50g, for 15 seconds. The data were submitted to ANOVA and Tukey's test (5%). The results of bond strength showed that the P5 group presented significantly higher resistance values than the other groups.The CL group presented a lower bond resistance than the group previously mentioned, though higher than the other groups. There was no statistic difference between the groups P2, P3, P10, P15 and CH. The results of Knoop hardness showed that the groups CH and P15 presented higher values of Knoop hardness in surfaces up to 4 mm deep. The specimens of the CL group presented the lowest averages of hardness. At 3 mm deep, the Knoop hardness of ali groups was statistically inferior to the surface hardness. The second study evaluated the bond strength through the push out method and the Knoop hardness of the dental composite Z250 (3MIESPE), photoactivated with halogen lamp unit XL2500 (3MIESPE), using different protocols of photoactivation: continuous mode (700mW/cm2 for 20s) (CO); soft-start (50 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (551); soft-s/art (100 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (552); soft-start (150 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (553); soft­start (200 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (554); soft-s/art (250 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (555); soft-start (300 mW/cm2 for 5s, followed by 700 mW/cm2 for 15s) (556). For the push ou! test and Knoop hardness test the specimens were made how the first experiment. The data were submitted to ANOVA and Tukey test (5%). The results showed that the 553 group obtained the higher bond strength when compared to the CO group. There were no differences among the other modes of soft-s/art in relation to the other groups. The other results in hardness, showed no statistic differences among the groups in the surface region and up to 4 mm depth. It was also observed that within each group there were no statistic differences between the surface region up to the 2 mm depth. The third study evaluated the bond strength through the push out method of the dental composite Z250 (3M/E5PE), photo activated with halogen lamp unit XL2500 (3MIE5PE), using different protocols of photo activation: soft-s/art (150 mW/cm2 for 2s(552), 3s(553), 5$(555), 10$(5510) or 15 seconds (5515), followed by 700 mW/cm2 for 15 seconds); pulse-de/ay (150 mW/cm2 for 2s(P2), 3s(P3), 5s(P5), 10s(P10) or 15 seconds (P15), with a 1-minute delay, followed by 700 mW/cm2 for 15 seconds). For the push out test the specimens were made how the first experiment. The data were submitted to ANOVA and Tukey test (5%). The results showed there were no statistic differences among groups photo activated using soft-s/art mode. For pulse delay mode P5 obtained the highest bond strength, statistically higher than other groups. The groups photoactivated with pulse-de/ay mode showed bond strength statistically higher than soft-s/art mode / Doutorado / Doutor em Materiais Dentários
118

Influência do grau de conversão do cimento e do procedimento adesivo na retenção de pinos intra-radiculares / Influence of cement degree of conversion and adhesive procedure on retention of root canal posts

Faria e Silva, André Luis January 2006 (has links)
Sistemas de união convencionais de dois passos e autocondicionantes de passo único podem ser incompatíveis com cimentos resinosos duais quando estes não são fotoativados. Os objetivos deste trabalho foram avaliar em três diferentes profundidades (terços cervical, médio e apical): (1) o grau de conversão do cimento resinoso RelyX ARC fotoativado através de dois pinos intra-radiculares com diferentes graus de translucidez, o pino de fibra de quartzo translúcido Light-Post (LP) e o pino de fibra de carbono envolto por fibra de quartzo Aestheti-Post (AP); (2) a resistência de união a push-out destes dois pinos e a influência do procedimento adesivo, utilizando um ativador químico ou a aplicação adicional de uma resina adesiva mais hidrófoba, sobre a retenção destes ao canal radicular. Para a mensuração do grau de conversão, foram confeccionadas matrizes de silicone de adição simulando canais radiculares. Os pinos, cinco de cada, foram ?cimentados? nestas matrizes e, após a fotoativação, estes foram removidos para a leitura do espectro do cimento resinoso através do espectrômetro FT-Raman. O cálculo do grau de conversão foi realizado através da análise da mudança na proporção entre as alturas dos picos das ligações duplas de carbono alifática e aromática. Os dados foram submetidos a ANOVA um fator com parcela sub-dividida e teste de Tukey (?=0,05). Apenas no terço médio o cimento resinoso apresentou maior grau de conversão quando fotoativado através do pino LP em relação ao AP. Para LP, o grau de conversão do cimento nos terços cervical e médio não diferiu estatisticamente, sendo inferior no terço apical. Já para AP, não houve diferença estatisticamente significante entre os terços apical e médio, que apresentaram graus de conversão inferiores ao terço cervical. Para a segunda proposição, foram utilizadas sesseenta raízes de incisivos bovinos para avaliar a retenção dos pinos, sendo alocadas dez para cada procedimento adesivo: PB (Prime&Bond 2.1), PB + SC (Self-cure activator), PB + SBM (adesivo do sistema Scotchbond Multi-purpose), BB (Brush&Bond), BB + CAT (catalisador químico) e BB + SBM. Para cada procedimento adesivo, foram utilizados os pinos LP e AP (n=5). Após tratamento endodôntico e cimentação dos pinos com cimento resinoso RelyX ARC, as raízes foram seccionadas no sentido mesio-distal de forma a obter duas secções terço, uma para o ensaio de push-out e outra para análise das interfaces de união em MEV. O teste push-out foi realizado em máquina de ensaio EMIC a uma velocidade de 0,5 mm/min. O padrão de fratura das amostras foi avaliado em estereomicrocópio e classificado em: tipo 1- interface cimento/pino, tipo 2 - mista e tipo 3 - interface cimento/dentina. A análise estatística dos dados foi feita através de ANOVA dois fatores com parcela sub-dividida e teste de Tukey (?=0,05). Não houve diferença estatisticamente significante entre as médias dos dois pinos. O terço apical apresentou os menores valores de retenção e não houve diferença estatisticamente significante entre os terços médio e cervical. Para os dois sistemas adesivos, PB e BB, a utilização da resina adesiva hidrófoba SBM aumentou a retenção dos pinos. Já a utilização dos catalisadores SC e CAT não alterou os valores de resistência de união por push-out. Entretanto, não houve diferença estatística entre a utilização dos catalisadores e a aplicação da resina adesiva SBM. _________________________________________________________________________________________ ABSTRACT: Two-step etch-and-rinse and one-step self-etching bonding systems may be incompatible with dual-cured resin cements when these are not photo activated. The aims of this study were to assess the following, at three different depths (cervical, middle and apical thirds): (1) the degree of conversion of the resin cement RelyX ARC, photo activated through two intra-radicular posts with different degrees of translucence, the translucent quartz fiber-post Light-Post (LP) and and the quartz-coated-carbon-fiber post Aestheti-Post (AP); (2) the push-out bond strength of these posts and the influence of the adhesive procedurea, using a chemical co-initiator or an additional coat of a more hydrophobic bonding resin, on their retention in the root canal. In order to measure the degree of conversion, polyvinylsiloxane matrices were confected to simulate root canals. The posts, five of each one, were cemented in these matrixes and, after photo activation, these were removed for reading the resin cement spectrum with the FT-Raman spectrometer. The degree of conversion calculation was made by analyzing the changes in the ratio between the heights of the peaks of aliphatic and aromatic carbon double bonds. Data were submitted to the split-plot ANOVA one-way and Tukey test. The resin cement presented the highest degree of conversion only in the middle third, when photo activated through the LP post in comparison with AP. For LP, cement degree of conversion in the cervical and middle thirds did not differ statistically, being inferior in the apical third. Whereas for AP, there was no difference statistically significant between the apical and middle thirds, which presented degrees of conversion inferior to that of the cervical third. For the second proposition, sixty bovine incisor roots were used to assess post retention, ten roots were used for each adhesive procedure: PB (Prime&Bond 2.1), PB + SC (Self-cure activator), PB + SBM (Scotchbond Multi-purpose system adhesive), BB (Brush&Bond), BB + CAT (chemical catalyzer ) and BB + SBM. For each adhesive procedure, the LP and AP posts were used (n=5). After endodontic treatment and cementing the posts one with RelyX ARC resin cement, the roots were mesio-distally sectioned to obtain two sections per third, one for the push-out test and one for SEM analysis of the bonded interfaces. The push-out test was performed in an EMIC test machine at a crosshead speed of 0.5 mm/min. The failure mode of the specimens was analyzed under a stereomicroscope and classified as follows: Type 1- cement/post interface, Type 2 - mixed and Type 3 - cement/dentin interface. Data were statistically analyzed by split-plot ANOVA two-way and Tukey test (?=0.05). There was no difference statistically significant between the mean values of the two posts. The apical third presented the lowest retention values, and there was no difference statistically significant between the middle and cervical thirds. For the two adhesive systems, PB and BB, the use of hydrophobic adhesive resin SBM increased post retention. Whereas the use of SC and CAT catalyst did not alter the push-out bond strength values. Nevertheless, there was no statistical difference between the use of the catalysts and the application of SBM adhesive resin.
119

Influencia do oxido de zinco e engenol contido nos cimentos provisorios sobre a remoção, por tração, de coroas totais de niquel-cromo cimentadas sobre dentina

Martins, Fabio 13 December 1995 (has links)
Orientador: Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T22:42:26Z (GMT). No. of bitstreams: 1 Martins_Fabio_M.pdf: 2362375 bytes, checksum: a4ea8d366eb5f9745448010ec9bd2b91 (MD5) Previous issue date: 1995 / Resumo: o objetivo deste estudo foi verificar a resistência à tração de retentores totais metálicos, cimentados em dentes humanos, utilizando cimento provisório a base de óxido de zinco contendo ou não eugenol, previamente a cimentação com três cimentos definitivos: um cimento de fosfato de zinco, um cimento de ionômero de vidro e um cimento resinoso. Foram usados 45 dentes molares humanos hígidos recém-extraídos. Após a profilaxia, as raízes de cada dente foram incluídas com resina acrílica quimicamente ativada em tubos de P.V.C.. A coroa de cada dente foi preparada em tomo mecânico até a obtenção da forma de um preparo cônico para coroa total. Em seguida, os retentores foram obtidos através da técnica de fundição de liga à base de Ni-Cr pelo método da cera perdida. As amostras foram divididas em três grupos de 15 unidades~ e cada grupo foi subdividido em três subgrupos de 5 unidades. A cimentação foi realizada através de ll!ll dispositivo de carga estática compressiva de 15Kg durante 15 minutos e os testes de tração através de urna máquina de ensaio universal. O grupo número 1 não recebeu cimentação provisória (Controle), e cada subgrupo foi cimentado com um dos cimentos definitivos. O grupo número 2 recebeu cimentação provisória com cimento Temp Bond e posterior cimentação definitiva da mesma forma que o grupo 1. O grupo número 3 recebeu cimentação provisória com cimento T emp Bond NE e cimentação definitiva como o descrito anteriormente. A análise de variância e o teste de Tukey mostraram que os valores médios obtidos para os três grupos (Controle,Bond e Bond NE) não apresentaram diferenças estatisticamente significantes, detectando-as somente quando se comparou os três cimentos definitivos entre si ( Cimento de ionômero de vidro 20,379 kg/cm2 , cimento de fosfato de zinco 12,445 Kg/cm2 e o cimento resinoso 8,082 Kg/cm2 ) / Abstract: The object of this study was to verify the resistance to tension of total metalic crowns, cemented to human teeth with a provisional cement with a zinc oxide based material, with and without eugenol, previous to permanent cementation: zinc phosphate cement, glass ionomer cement and a resin cement. Forty-five sound, recent1y-extracted human molars were used. Afier previous prophilaxis, the roots of each tooth were embedded in chemically activated acrylic resin, in PVC tubes. The dental crown of each tooth was machined in a mechanical lathe until the form adequate for the preparation for a total crown was obtained. Afier this, the total crowns were obtained by the lost-wax dental casting method, using a Ni-Cr based alloy. The prepared teeth, with their respective cast crowns, were separed into three groups of 15 teeth each, and each group was divided into three sub-groups of 5 teeth each. Group number 1 don't receive provisional cementation (Control) and each sub-group was cemented with one of the three permanent cement. Group 2 was provisionally cemented with T emp Bond and afier definitive cementation with the same manner of the group number 1. Group number 3 received provisional cementation with Temp Bond NE and afier definitive cementation with the same manner of the group number 1 too. Analysis of the variations reeorded, in referenee to the Tukey test, showed that the average values obtained for the three groups (Control, Bond, Bond NE) did not show statistieally signifieant diferenees, showed that there was a statistieally signifieant differenee in a eomparison of the three materials one to the other (glass ionomer eement 20.379 Kg/cm2, zÍlle phosphate eement 12.445 Kg/cm2 and 8.082 Kg/cm2 for the resin eement) / Mestrado / Materiais Dentarios / Mestre em Odontologia
120

Reação dos tecidos periapicais a sobreobturações com diferentes cimentos endodonticos em duas consistencias : histopatologia em dentes de cães

Berbert, Christiane Camargo Villela, 1959- 29 May 1996 (has links)
Orientador: Luiz Valdrighi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T12:58:33Z (GMT). No. of bitstreams: 1 Berbert_ChristianeCamargoVillela_D.pdf: 4903497 bytes, checksum: 114710ddba468b63f57b0450cbcea845 (MD5) Previous issue date: 1996 / Resumo: A resposta da região periapical a obturações de canais radiculares, com extravasamento de cimentos obturadores para o periápice, foi estudada histologicamente. Nos grupos experimentais foram empregados 100 raÍzes de pré-molares de 12 cães adultos jovens que, após a pulpectomia, foram instrumentados com o rompimento da barreira cementária e ampliação até o diâmetro 40. Três cimentos obturadores foram testados: o Sealapex, o Fill canal e o Endomethasone, esses dois últimos em duas consistências diferentes - uma mais fluida e outra mais espessa. Após 14 e 90 dias, iniciou-se o preparo das peças para análise histológica, quando as raÍzes foram incluídas em parafina e cortes seriados de 7 111111 feitos no sentido mésio-distal dos dentes e receberam coloração pela hematoxilina-eosina. As avaliações histopatológicas demonstraram:' 1- há uma relação direta entre a quantidade de material obturador extravasado e a extensão do processo inflamatório, independentemente do material utilizado. 2- a consistência fluida dos cimentos eugenolatos tendeu a promover uma reação inflamatória mais intensa, principalmente aos 14 dias. 3- no período de 90 dias houve uma redução do processo inflamatório ao redor do material extravasado, com tendência evolutiva de reparo, seja por tecido fibroso, seja por tecido calcificado. 4-0 cimento Endomethasone tendeu a produzir uma reação periapical de prognóstico mais favorável que os demais materiais testados, especialmente aos 90 dias / Abstract: The aim of this study was to carry out a histologic investigation of apical region of dog's teeth after vital pulp extirpation and root canal instrumentation beyond the tooth apei:o The fi(lings were placed forced periapically with Sealapex, Endomethasone and Fill canal cements.Endomethasone and Fill canal root cements were manipulated as both, soft fluid past and as a more consistent formo The dogs were killed after 14 and 90 days and the jaws were sectioned and embedded in paraffin. Seven-micrometer serial sections were stained with hematoxylin and eosin and observed microscopic examination. The findings showed that: 1- independent of material studied, there was a direct relation between the ' amount of overextrusion and the extent oi inflammatory processes. 2- in the overextrusion with ZOE materiaIs, there was a direct relation between the consistence of the material and the intensity and extent of the inflammatory processo 3- intensity of inflammation decreased progressively with time, tissue repair occored with deposition of the fibrous connective tissue and calcified material. 4- the healing process of dog apical tissue in teeth filled with Endomethasone was more efficient, than other materiaIs, specially after 90 days / Doutorado / Endodontia / Doutor em Clínica Odontológica

Page generated in 0.1235 seconds