• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico

Villaça-Carvalho, Maria Fernanda Lima [UNESP] 12 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-12Bitstream added on 2014-06-13T18:58:43Z : No. of bitstreams: 1 carvalho_mflv_me_sjc.pdf: 376473 bytes, checksum: fd3cb649deb141adcb6ff92fcc6eaeb7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists
102

Influência da adição de nanopartículas de sílica nas propriedades mecânicas de gessos odontológicos

Cesero, Leonardo de January 2017 (has links)
Made available in DSpace on 2018-05-09T12:03:29Z (GMT). No. of bitstreams: 1 000488694-Texto+Completo-0.pdf: 930355 bytes, checksum: 2c97f9568abe8fdc237aa889661c8a3c (MD5) Previous issue date: 2017 / The current applications of nanotechnology in dentistry include adhesive systems and composite resins, but they are still quite limited in dental materials. Dental stone is a widely used material, and the incorporation of silica nanoparticles is still unexplored. The purpose of this study is to evaluate the behavior of the mechanical properties of dental stones with the addition of silica nanoparticles at different concentrations. A total of 180 samples were prepared, 90 for each dental stone (Durone and Fuji Rock). For the control group (CG), no silica particles were added, while test group 1 (TG1) had silica nanoparticles added to 1% by weight, and test group 2 (TG2) had silica nanoparticles added to 5% by weight. The roughness, diametral tensile strength (DTS) and compressive strength were measured 24 hours after the start of spatulation. The mean roughness values for Durone were CG= 0,55, TG1= 0,36 and TG2= 0,28 μm and for Fuji Rock were CG= 0,47, TG1= 0,31 and TG2= 0,35 μm. The mean DTS values for Durone were CG= 6,03, TG1= 5,17 and TG2= 5,02 MPa and for Fuji Rock were CG= 6,41, TG1= 5,23 and TG2= 4,56 MPa. The mean compressive strength values for Durone were CG= 35,44, TG1= 32,70 and TG2= 32,44 MPa and for Fuji Rock were CG= 42,97, TG1= 31,22 and TG2= 29,86 MPa. Surface roughness was statistically lower for the Durone and Fuji Rock stones (p< 0,001) when silica nanoparticles were added. For DTS and compressive strength, the addition of silica nanoparticles did not lead to statistically better results when compared to the control groups (p> 0,05). / A nanotecnologia na Odontologia está presente nos sistemas adesivos e nas resinas compostas, sendo sua aplicação ainda bastante limitada nos materiais dentários. O gesso odontológico é um material amplamente utilizado e a incorporação de nanopartículas de sílica é desconhecida. O objetivo do estudo é avaliar o comportamento das propriedades mecânicas dos gessos odontológicos a partir da adição de nanopartículas de sílica em diferentes concentrações. Foram confeccionadas 180 amostras, sendo 90 para cada gesso (Durone e Fuji Rock). No grupo controle (GC) não foram adicionadas partículas, no grupo teste 1 (GT1) foram adicionadas 1% em peso e o grupo teste 2 (GT2) recebeu 5% em peso de nanopartículas de sílica. Os testes de rugosidade, tração diametral (DTS) e compressão foram realizados após 24 horas do início da espatulação. Os valores médios de rugosidade para o Durone foram de GC= 0,55, GT1= 0,36 e GT2= 0,28 μm e para o Fuji Rock foram de GC= 0,47, GT1= 0,31 e GT2= 0,35 μm. Para DTS foram de GC= 6,03, GT1= 5,17 e GT2= 5,02 MPa para o Durone e para o Fuji Rock foram de GC= 6,41, GT1= 5,23 e GT2= 4,56 MPa. Para compressão foram de GC= 35,44, GT1= 32,70 e GT2= 32,44 MPa para o Durone e para o Fuji Rock foram de GC= 42,97, GT1= 31,22 e GT2= 29,86 MPa. Houve uma menor rugosidade superficial estatisticamente para os gessos Durone e Fuji Rock (p< 0,001) quando adicionadas nanopartículas de sílica. Para a DTS e compressão não houve estatisticamente resultados melhores quando adicionadas nanopartículas de sílica em comparação aos grupos controles (p> 0,05).
103

Avaliação da prevalência de canais mandibulares bífidos em tomografia computadorizada por feixe cônico /

Villaça-Carvalho, Maria Fernanda Lima. January 2012 (has links)
Orientador: Júlio Cézar de Melo Castilho / Banca: Leonardo Marchini / Banca: Rívea Inês Ferreira / Resumo: O canal mandibular pode apresentar diferentes morfologias, em alguns casos, existe a presença de um canal acessório chamado bífido. O objetivo deste estudo foi avaliar a prevalência de canais mandibulares bífidos (CMB) por meio de Tomografia Computadorizada por Feixe Cônico (TCFC). Examinaram-se tomografias de 300 pacientes tanto do sexo masculino quanto do feminino, com idade compreendida entre, 25 a 87 anos, submetidos ao exame para avaliação da mandíbula. Os indivíduos foram divididos em dois grupos de acordo com o sexo, GM para o masculino e GF para o feminino, e dois subgrupos de acordo com o lado examinado, D para o direito e E para o esquerdo. Todas as aquisições tomográficas seguiram um mesmo protocolo de aquisição e a análise das imagens se deu num mesmo software. Foram utilizados filtros de imagens associados aos cortes transversais, oblíquos e reconstrução panorâmica para análise do CMB. Realizaram-se análises descritivas dos valores e comparações entre os fatores pelo teste Anova com significância de 95%. Foi possível observar que os CMB ocorreram em 80 casos (26,67%), destes, 39 (48,75%) no sexo masculino e 41 (51,25%) no feminino, não sendo verificadas diferenças nas mensurações comparadas por sexo (masc p=0,788; fem p=0,140) nem por lado acometido (dir p=0,365; esq p=0,412), apesar do direito ter sido mais frequente (66,67%) em ambos os sexos. Desta forma, pode-se concluir que a prevalência dos CMB é significante e não deve ser negligenciada pelos cirurgiões dentistas / Abstract: The mandibular canal can have different morphologies, in some cases is present a second canal (bifid). The aim of this study was to evaluate the incidence of bifid mandibular canals (BMC) by Cone Beam Computed Tomography (CBCT). Cone beam CT scans of 300 patients, both male and female, aged 25 to 87 years old, who underwent the examination for evaluation of the mandible, were examined. Patients were divided into two groups according to sex, GM for male and GF for females, and two subgroups according to the side examined, R for right and L for left. All tomographic acquisitions were followed by the same protocol and images analysis were made on the same software. Image filters associated with cross-seccional slices, oblique and panoramic reconstruction for the analysis of BMC were used. Analyses of descriptive values and comparisons were made between ANOVA test with a significance of 95%. It was observed that there were 80 cases of BMC (26. 67%), 39 (48. 75%) in male and 41 (51. 25%) in females. There was no difference in measurements compared by sex (p=0.788 male; p=0.140 female) and for the affected side (p=0.365 right, p=0.412 left), although the right side was more frequent (66.67%) in both sexes. Thus, it can be concluded that the incidence of BMC is relevant and should not be overlooked by dentists / Mestre
104

Adaptação marginal e resistência à fratura de coroas totais executadas em diferentes sistemas /

Campos, Roberto Elias. January 2005 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Adair Luiz Stefanello Busato / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi avaliar a adaptação marginal e a resistência à fratura de coroas totais metalocerâmicas e de coroas sem reforço de infra-estrutura metálica, utilizando-se diferentes sistemas restauradores. Foram selecionadas 48 raízes de dentes bovinos com diâmetros e formas semelhantes, seccionadas com 15 mm de comprimento. Após tratamento endodôntico e alívio do conduto pinos metálicos com 12 mm de comprimento foram fixados com cimento de fosfato de zinco e um preenchimento coronário de resina composta micro-híbrida foi construído com 3 mm de altura e convergência axial de aproximadamente 6 graus. O término cervical foi o ombro arredondado com 1,0 mm de largura. As amostras preparadas e seus respectivos modelos foram aleatoriamente distribuídos em 6 grupos com 8 amostras cada. As amostras foram, então, submetidas a carga de compressão em uma máquina de ensaios EMIC, a uma velocidade de 1 mm/min.. Após obtenção dos valores de resistência à fratura cada amostra foi submetida a uma inspeção visual na lupa estereoscópica para análise do modo de fratura. Para os valores de resistência à fratura, submetidos à análise estatística, o teste de Kruskall-Wallis acusou diferença significante e o teste U de Mann-Whitney indicou os locais de diferença. A análise do modo de fratura mostrou que o remanescente dental foi pouco afetado nas amostras dos grupos das coroas metalocerâmicas (Grupos A e B). Nos grupo C, D e E metade das fraturas ocorreu envolvendo somente o preenchimento coronário e a outra metade envolveu o preenchimento e a raiz do remanescente. O grupo F apresentou 100% de envolvimento do remanescente dental com fraturas cervicais ou longitudinais. Para os dados relativos à adaptação marginal o teste estatístico ANOVA não acusou diferença significante. Todos os grupos apresentaram valores dentro do limite de 100 æm, aceitável clinicamente. / Abstract: The aim of this study was to evaluate the marginal adaptation and fracture resistance of metal-ceramic and metal-free prosthetic unit crowns made with different systems. Forty-eight bovine roots with 15 mm in length were used. After endodontic treatment a metallic post (12 mm) was fixed with zinc phosphate cement and a core of micro-hybrid resin was built up with 3 mm in height, round shoulder cervical termination with 1,5 in width and an approximate axial convergence of 6 degree. Fracture failure mode showed that subjacent structure were little affected in the specimens of metal ceramic groups (A and B). However, inside groups C, D and E half of the fractures involved only the core and the other half involved the core and the remaining dental root. The most catastrophic was the group F with 100% of dental remaining involved, showing cervical and longitudinal fractures in the roots. For marginal adaptation Analysis of Variation (p<0,05) showed no differences among all groups. Means of each group were: A - (74 æm); B (102 æm); C (87 æm); D (99 æm);E (80 æm); F (100 æm). All groups had marginal gap within 100 æm, clinically accepted. / Doutor
105

Eficiência de detergentes e EDTA na remoção da "smear layer" de superfícies radiculares submetidas a raspagem e aplainamento : análise através da microscopia eletrônica de varredura /

Sampaio, José Eduardo Cezar. January 1999 (has links)
Resumo: A remoção da "smear layer" é um procedimento importante para a regeneração periodontal e para o tratamento da sensibilidade dentinária. Diversos tratamentos tem sido realizados para sua remoção, porém, mostrando resultados conflitantes ou insatisfatórios. No presente estudo nos propomos a analisar através do microscópio eletrônico de varredura a eficiência dos detergentes: lauril sulfato de sódio, Plax e de mamona assim como o EDTA 24% na remoção da "smear layer". Todos os produtos testados foram aplicados com bolinha de algodão, renovada a cada 30 segundos, a qual era esfregada na superfície radicular por diferentes períodos. As fotomicrografias foram analisadas através da aplicação de um índice de remoção da "smear layer" por três examinadores calibrados e os resultados analisados estatisticamente. De acordo com nossos resultados pudemos chegar as seguintes conclusões: 1- a instrumentação com curetas de Gracey provocou a formação da "smear layer"; 2- o detergente lauril sulfato de sódio não removeu a "smear layer", tendo sido o pior resultado entre os detergentes testados; 3- Os detergentes Plax e de mamona mostraram resultados semelhantes entre si e superiores ao controle negativo e ao lauril sulfato de sódio, porém, não removeram a "smear layer" satisfatoriamente; 4- O EDTA 24% neutro mostrou ser eficiente para a remoção da "smear layer". / Abstract: Removal of the smear layer is an important procedure to achieve periodontal regeneration and to the treatment of dentinal sensitivity. A number of treatments have been used to this end although the results turned out to be conflicting or unsatisfactory. In the present study we intended to perform a SEM evaluation of the efficiency of the following detergents on smear layer removal: sodium lauryl sulphate, Plax, castor-oil bean and EDTA 24%. These substances tested were applied topically with a small piece of sterile cotton which was rubbed on root surface for different periods of time and changed every 30 seconds. The microphotographs were evaluated by three independent previously calibrated examiners that classified them according to a smear layer removal index and the results were subjected to a statistical analysis. The results obtained led to the following conclusions: 1-hand instrumentation with Gracey curettes elicited the formation of smear layer; 2-sodium lauryl sulphate did not remove the smear layer and showed the worst results of all detergents tested; 3-Plax and castor-oil detergents showed similar results represented by a partial removal of the smear layer, and these results were better than those obtained in the negative control and sodium lauryl sulphate groups; 4-neutral EDTA 24% was the most efficient detergent on smear layer removal.
106

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria /

Vasconcellos, Luis Gustavo Oliveira de . January 2008 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Renato Sussumu Nishioka / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / Abstract: The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain. / Mestre
107

Biocompatilibidade in vivo de implantes de titânio submetidos ao processo biomimético /

Machado, Ana Cristina Posch. January 2008 (has links)
Resumo: Propõe-se neste estudo avaliar a neoformação óssea no interior dos poros e ao redor de implantes porosos de titânio, submetidos ao processo biomimético modificado, inseridos em tíbias de coelhos. Foram confeccionados 180 implantes de titânio puro grau 2, com porosidade controlada, obtidos por meio da metalurgia do pó. Noventa implantes foram pré-tratados com solução de NaOH à 130ºC/1h, submetidos à temperatura de 200ºC/1h e posteriormente imersos em fluido corpóreo simulado modificado por 14 dias. Os implantes foram inseridos em 30 coelhos sendo que cada um recebeu 3 implantes tratados na tíbia esquerda e 3 sem tratamento na tíbia direita. Os animais foram sacrificados em 15, 30 e 45 dias após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica, histomorfométrica e teste mecânico de cisalhamento. A análise microestrutural das amostras foi realizada por microscopia eletrônica de varredura (MEV), espectrometria por energia dispersiva de raios X (EDS) e espectroscopia Raman e a avaliação da neoformação óssea por microscopia de luz (MO) e MEV, comparando implantes sem tratamento com aqueles submetidos ao tratamento biomimético. O EDS indicou que a superfície do implante após o tratamento biomimético continha principalmente cálcio (Ca) e fósforo (P) além da presença de titânio. A Espectroscopia Raman do implante de titânio, após o tratamento biomimético, indicou pico característico e de grande magnitude a 960cm-1 devido à formação de uma camada de hidroxiapatita. As imagens ao MO e MEV demonstraram que houve neoformação óssea na interface osso-implante e no interior dos poros, inclusive naqueles mais centrais. Observou-se que a porcentagem média de neoformação óssea nos implantes tratados nos três tempos de sacrifício foi maior do que nos implantes não tratados, sendo observada diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study is to define the coating on porous titanium implants submitted to modified biomimetic process and to evaluate bone neoformation inside the porous and around these implants when inserted in tibiae of rabbits. One hundred and eighty pure titanium implants, fabricated by powder metallurgy, were made. Ninety implants were pretreated with NaOH solution at 130ºC/1h and submitted to the temperature of 200ºC/1h and immersed in modified simulated body fluid for 14 days. The implants were inserted in 30 rabbits; each rabbit received 3 treated implants in the left tibia and 3 untreated implants in the right tibia. The animals were sacrificed after 15, 30, and 45 days of surgery and the tibia fragments containing the implants were submitted to histological and histomorphometric analyses and shear strength test. The microstructure analysis of the samples was performed by scanning electron microscope (SEM), energy dispersive spectrometry (EDS) and Raman spectroscopy; the bone neoformation was evaluated by light microscopy (MO) and SEM comparing only sinterized implants with those submitted to biomimetic treatment. The EDS indicated that the implant surface after biomimetic treatment contained mainly calcium (Ca) and phosphorous (P) in addition to the presence of titanium. The Raman spectroscopy of the titanium implant, after biomimetic treatment, indicated the formation of a hydroxyapatite layer due to the characteristic peak and of great magnitude at 960cm-1. The MO and SEM images showed bone neoformation on the interface bone-implant and inside the porous, including the most internal ones. It was observed that the mean percentage of bone neoformation in the treated implants for the three sacrifice periods were higher than the untreated implants, statistically significant for the 15-day period. The mechanical test showed that the coated implants... (Complete abstract, click electronic access below) / Orientador: Yasmin Rodarte Carvalho / Coorientador: Marize Varella de Oliveira / Banca: Yasmin Rodarte Carvalho / Banca: Marize Varella de Oliveira / Banca: Luana Marotta Reis de Vasconcellos / Banca: Paulo Tambasco de Oliveira / Banca: Carlos Alberto Alves Cairo / Banca: Monica Calixto Andrade / Doutor
108

Influência da adição de surfactantes a géis clareadores à base de peróxido de hidrogênio a 35% e peróxido de carbamida a 10% na efetividade do clareamento dental: estudo in vitro /

Caneppele, Taciana Marco Ferraz. January 2008 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Carlos Rocha Gomes Torres / Banca: José Roberto Rodrigues / Banca: Glauco Fioranelli Vieira / Resumo: Este estudo avaliou a influência da adição de diferentes tipos de surfactantes na efetividade de géis clareadores a base de peróxido de hidrogênio a 35% (PH) e peróxido de carbamida a 10% (PC), durante o processo de clareamento, através da análise da cor dos elementos dentais. Foram utilizados cento e quarenta dentes bovinos, os quais foram escurecidos através da imersão em solução de café solúvel, vinho tinto e fumo, por uma semana. Terminado o processo de escurecimento, foi delimitada uma área de leitura da cor e realizada a leitura inicial, através do espectrofotômetro Easy Shade. Os espécimes foram divididos em sete grupos: a) controle negativo (CN); b) controle positivo para PH (CP-35); c) PH + Tween 20 (T20-35); d) PH + lauril sulfato de sódio (LSS-35); e) controle positivo para PC (CP-10); f) PC + Tween 20 (T20-10); g) PC + lauril sulfato de sódio (LSS-10). O grupo CN foi mantido em saliva artificial por 21 dias. Os grupos CP-35, T20-35 e LSS 35 receberam 3 aplicações de gel clareador por 10 minutos e após 7 dias repetiu-se o processo. Os grupos CP-10, T20-10 e LSS-10 receberam o gel 8 horas por dia por 14 dias. A cor dos espécimes foi lida após a primeira e segunda sessão para os grupos com PH, e após 7 e 14 dias para os grupos com PC. Todos os espécimes tiveram sua cor medida uma semana após o término do clareamento. Os testes de análise de variância e Tukey mostraram diferenças estatisticamente significantes para os parâmetros de L, a, b e E dos géis de PH com surfactante para o gel CP-35. Concluiu-se que a adição de surfactantes ao gel clareador a base de PH aumentou a efetividade do clareamento...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the addition of different types of surfactants in the effectiveness of 35% hydrogen peroxide and 10% carbamide peroxide agents, during the bleaching process, through the color analysis of the dental elements. One hundred and forty bovine teeth had been used, which had been darkened through the immersion in coffee solution, red wine and tobacco, for one week. Finished the darkened process, an area of color reading was delimited and the initial measurement of the color was carried through Easy Shade spectrophotometer. The specimens had been divided in seven groups: a) the negative control (CN); b) positive control for PH (CP-35); c) PH + Tween 20 (T20-35); d) PH + lauril sodium sulphate (LSS-35); e) positive control for PC (CP-10); f) PC + Tween 20 (T20-10); g) PC + lauril sodium sulphate (LSS-10). Group CN was kept in artificial saliva for 21 days. Groups CP-35, T20-35 and LSS 35 had received 3 applications from bleaching agents for 10 minutes and after 7 days the process was repeated. Groups CP-10, T20-10 and LSS-10 had received the bleaching agents 8 hours for day for 14 days. The color of specimens was measured after first and second session for the groups with PH, and after 7 and 14 days for the groups with PC. All the specimens had its measured color one week after the finished of the bleaching. The tests of analysis of variance and Tukey had shown significant differences for the parameters of L, a, b and E of the PH agents with surfactants for the CP-35. It was concluded that the addition of surfactants to the 35% PH bleaching agents increased the effectiveness of the dental bleaching. / Mestre
109

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever /

Mesquita, Alfredo Mikail Melo. January 2008 (has links)
Orientador: Estevão Tomomitsu Kimpara / Banca: Estevão Tomomitsu Kimpara / Banca: Rander Pereira Avelar / Banca: Eduardo Miyashita / Banca: Rubens Nisie Tango / Banca: Marco Antonio Bottino / Resumo: O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / Abstract: The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn't difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated. / Doutor
110

Avaliação de diferentes tratamentos de superfície na resistência de união de cerâmica de di-silicato de lítio /

Feitosa, Fernanda Alves. January 2014 (has links)
Orientador: Cesar Rogério Pucci / Co-orientador: Rodrigo Máximo de Araujo / Banca: Antonio Marcio Resende do Carmo / Banca: Maria Filomena Rocha Lima Huhtala / Resumo: O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos de superfície na resistência de união entre a cerâmica de di-silicato de lítio IPS e.max Press (IvoclarVivadent, Liechtenstein) e o cimento resinoso Variolink II (Ivoclar Vivadent, Liechtenstein) quando submetidos a teste de tração. Para isso 330 bases tronco-cônicas de cerâmica de di-silicato de lítio foram aleatoriamente divididas em 11 grupos de acordo com o tratamento a ser realizado: C - grupo controle; J - Jateamento com óxido de alumínio (50 μm); JAr - Jateamento com óxido de alumínio (30 μm) e secagem do silano com ar quente; GEr - Revestimento da superfície com grafite e tratamento com laser Er:YAG(200 mJ de intensidade de energia e 10 Hz de frequência); GErAr - Revestimento da superfície com grafite, tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; Er - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de freqüência); ErAr - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; GNd - revestimento da superfície com grafite e tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); GNdAr - Revestimento da superfície com grafite, tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente; Nd - Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); NdAr - Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente. O cimento resinoso que uniu os espécimes foi fotoativado por 40 segundos utilizando o aparelho LED (Radii cal-SDI). Então, foi realizada a ciclagem termomecânica com carga de 60N, 1.000 ciclos termicos e 24000 mecânicos e o ensaio ... / Abstract: The aim of this study was to evaluate the bond strength afforded by different surface treatments on IPS e.max Press ceramic united to Variolink II (both Ivoclar-Vivadent, Liechtenstein), when subjected to tensile test. 330 ceramic bases were divided into 11 groups in accordance with the surface treatment performed: C - control group J - aluminum oxide sandblast, JAraluminum oxide sandblast and silane hot air dry, GEr - surface coating with graphite and treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz), GErAr - surface coating with graphite, treatment with Er: YAG laser (200 mJ of energy intensity and 10 Hz frequency) and silane hot air dry; Er - treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz) ErAr - treatment with Er: YAG laser (200 mJ intensity energy and 10 Hz frequency) and silane hot air dry; GNd - coating the surface with graphite and treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz); GNdAr - coating the surface with graphite , treatment with Nd: YAG laser (120 mJ of energy intensity and 15 Hz frequency) and silane hot air dry; Nd - treatment with Nd: YAG laser (120 mJ of energy intensity and frequency 15 Hz); NdAr - treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz) and silane hot air dry. The resin cement that unite the specimens was cured for 40 seconds using the LED cure equipment (Radii-cal SDI). Then they were termomechanical cycled (60N, 1,000 thermical cycles and 24000 mechanical) and were submitted to the tensile test in a universal testing machine EMIC-2000. Data were tested for Dunnet ( α = 5 % ) and 3 ANOVA Way . The Er group showed higher tensile strength greater than the control group and the other groups, while the NdG group presented results of bond strength lower than the control group and the other surface treatments. The other groups did... / Mestre

Page generated in 0.0841 seconds