• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Avaliação dimensional de modelos de gesso em função de diferentes tecnicas e materiais de moldagem elastomericos / Dimensional evaluation of stone models in function of different techniques and elastomeric impression materials

Vitti, Rafael Pino, 1984- 02 November 2009 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade EStadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T09:01:20Z (GMT). No. of bitstreams: 1 Vitti_RafaelPino_M.pdf: 8432913 bytes, checksum: 82945cbea8656d59d74e27161eec09f2 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi medir e comparar a precisão dimensional de modelos de gesso confeccionados a partir de três técnicas de moldagem com dez diferentes elastômeros. Um modelo em cera, simulando um arco dental mandibular, teve retirados os dentes 44, 45 e 46 a fim de avaliar possíveis diferenças de precisão entre os lados direito e esquerdo, pelo maior volume de material de moldagem do lado direito, o que poderia acarretar em maior contração e conseqüentemente maior alteração desse lado. A partir desse modelo em cera foi obtido um modelo metálico padrão com pontos de referência nos dentes 33 (CE), 43 (CD), 37 (ME) e 47 (MD) que foi utilizado para a realização das moldagens. Foram medidas as distâncias entre os dentes CE-CD, ME-MD, CEME e CD-MD. Moldeiras metálicas de estoque foram usadas para as técnicas do reembasamento e dupla mistura. Já para a técnica da moldeira individual, moldeiras de resina acrílica foram confeccionadas com alívio interno de aproximadamente 2mm. Adesivos específicos para cada material foram usados nas moldeiras individuais, para promover adesão na moldeira. Todos os procedimentos de moldagem foram realizados em uma sala com temperatura e umidade relativa controladas. A manipulação dos materiais foi feita segundo as instruções dos fabricantes. O movimento de retirada da moldeira, após a presa do material de moldagem, foi padronizado por meio de um equipamento pneumático evitando possíveis distorções no molde. Os modelos de gesso foram vazados após trinta minutos da obtenção dos moldes, para promover a recuperação elástica dos materiais. Foram confeccionados cinco corpos-de-prova para cada marca comercial de elastômero e técnica de moldagem, totalizando cento e trinta amostras. Após 24 horas, foi feita a separação molde-modelo, sendo o modelo observado em microscópio comparador com 30x de aumento. Três leituras foram feitas em cada uma das distâncias analisadas, obtendo-se uma média que foi, posteriormente, analisada estatisticamente, por meio da análise de variância com três fatores ou com dois fatores e as médias comparadas pelo teste de Tukey (5%). Os resultados demonstraram que os silicones polimerizados por adição foram os materiais que mostraram melhores resultados de precisão dimensional dos modelos. Os silicones polimerizados por condensação apresentaram os piores resultados. Todas as distâncias mensuradas apresentaram alterações lineares negativas (contração), sendo que as distâncias ântero-posteriores (CEME e CD-MD) sofreram mais alterações quando comparadas com as distâncias transversais (CE-CD e ME-MD). Num contexto geral, não houve diferença entre as distâncias MD-CD e ME-CE. Também não foram encontradas diferenças entre as técnicas de moldagem. A precisão dos modelos de gesso foi mais afetada pelos materiais do que pela técnica de moldagem. / Abstract: The aim of this study was assess and compare the dimensional accuracy of stone models made from of three impression techniques and ten different elastomeric materials. A wax model, simulating a lower dental arch, had removed the teeth 44, 45 and 46 in order to evaluate possible differences of accuracy between the right and left sides, by the bigger volume of impression material on the right side that could lead in bigger contraction and, consequently, bigger change in this side. From this wax model was obtained a metallic master model with reference points in the teeth 33 (LC), 43 (LM), 37 (RC) and 47 (RM) that was used for the accomplishment of the impressions. The distances were measured among the teeth LC-RC, LM-RM, LC-LM and RC-RM. Stock metallic trays were used for the putty/wash technique and double mix technique. For the single mix technique custom acrylic resin trays were made with internal relief of approximately 2mm. Specific adhesives for each material were used in the custom trays, to promote adhesion in the trays. All impressions procedures were made at room with temperature and relative humidity controlled. The materials handled were made following the manufacturers' instructions. The tray movement, after the impression aterial set, was standardized through of a pneumatic equipment avoiding possible distortions in the mold. The stone models were pouring after thirty minutes of the molds obtaining, to promote the materials elastic recovery. Five specimens were made for each elastomeric material commercial mark and impression technique, totaling one hundred thirty samples. After 24 hours, the separation mold/model was made, being the model observed in measuring microscope at 30x magnification. Three measurements were made in each one of the analyzed dimensions, getting a mean that was later analyzed statistically through of variance analysis three-way or two-way and the means compared by Tukey's test (5%). The results demonstrated that addition silicones were the materials that showed better results of models dimensional accuracy. The condensation silicones showed the worst results. All distances assessed showed negative linear change (contraction), being that the anteroposterior distances (LCLM and RC-RM) suffered more changes when compared with the transversal distances (LC-RC and LM-RM). In general, there wasn't difference between the distances LC-LM and RC-RM. There wasn't found differences between the impression techniques. The stone models accuracy was more affected by the materials than the impression technique. / Mestrado / Mestre em Materiais Dentários
142

Avaliação da regeneração ossea em defeitos peri-implantares de deiscencia tratados com uma abordagem combinada associando celulas derivadas da medula ossea e regeneração ossea guiada : estudo histomorfometrico em cães / Evaluation of bone regeneration in dehiscence type peri-implant defects treated with a combined approach using bone marrow-derived cells and guided bone regeneration : a histomorphometrical study in dogs

Ribeiro, Fernanda Vieira 12 September 2009 (has links)
Orientadores: Marcio Zaffalon Casati, Karina Gonzales Silverio Ruiz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:45:21Z (GMT). No. of bitstreams: 1 Ribeiro_FernandaVieira_D.pdf: 8018060 bytes, checksum: 8fc3b530db926d929facce5cfd30fb4e (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar histometricamente o reparo ósseo em defeitos periimplantares do tipo deiscência, criados cirurgicamente em cães, tratados com a associação de células derivadas da medula óssea (CMs) e regeneração óssea guiada (ROG). A medula óssea foi obtida a partir da crista ilíaca de oito cães beagle adultos machos. Células derivadas da medula óssea (CMs) foram isoladas, cultivadas in vitro e fenotipicamente caracterizadas com relação as suas propriedades osteogênicas. Os mesmos animais foram submetidos à extração bilateral dos primeiros molares e terceiro e quarto pré-molares inferiores. Após três meses, três leitos para a colocação de implantes foram confeccionados em cada lado da mandíbula, deiscências ósseas vestibulares foram criadas e, então, implantes de titânio de superfície usinada foram colocados. As deiscências ósseas foram tratadas aleatoriamente, de acordo com um dos seguintes grupos: 1) ROG+CMs+C: membrana de PTFE-e com reforço de titânio associada às células derivadas da medula óssea semeadas no carreador, 2) ROG+C: membrana de PTFE-e com reforço de titânio associada ao uso do carreador sem células, 3) CMs+C: células derivadas da medula semeadas no carreador, 4) ROG: membrana de PTFE-e com reforço de titânio, 5) C: carreador sem células e 6) Controle: nenhum tratamento. Após três meses, os animais foram sacrificados e os implantes em conjunto com os tecidos adjacentes foram processados laboratorialmente para obtenção de secções não descalcificadas. Os parâmetros avaliados foram: Contato direto osso-implante (CO), Preenchimento ósseo dentro das roscas do implante (PR) e Área de tecido ósseo fora das roscas (AF). In vitro, a caracterização fenotípica demonstrou que células derivadas da medula óssea apresentaram potencial osteogênico identificado pela formação de nódulos minerais e expressão de marcadores ósseos (fosfatase alcalina, sialoproteína óssea e colágeno tipo I). As análises histométricas revelaram que todos os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) demonstraram resultados estatisticamente similares (p>0,05) com relação à área de novo osso formado fora das roscas do implante, apresentando, no entanto, maior quantidade de osso neoformado fora dos limites das roscas, quando comparados aos demais grupos (CMs+C, C e Controle) (p<0,05). Adicionalmente, foi observado que o preenchimento ósseo dentro das roscas foi estatisticamente semelhante entre os grupos que utilizaram membrana (ROG+CMs+C, ROG+C, ROG) e o grupo tratado com células sem barreira (CMs+C) (p>0,05), enquanto todos estes grupos mostraram um preenchimento ósseo significativamente superior ao grupo Controle (p<0,05). Com relação à porcentagem de contato osso-implante, embora os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) tenham apresentado valores estatisticamente maiores quando comparados aos defeitos dos grupos C e Controle (p<0,05), uma tendência para aumento da extensão de contato osso-implante foi observada nos defeitos tratados com células sem a associação da ROG (grupo CMs+C). Dentro dos limites do presente estudo, pôde-se concluir que embora as células derivadas da medula óssea, utilizadas isoladamente, tenham promovido bons resultados em relação à formação óssea dentro das roscas do implante, o seu uso, associado à ROG, não promoveu benefícios adicionais na formação óssea em defeitos peri-implantares de deiscência. / Abstract: The purpose of this investigation was to histometrically evaluate the bone healing in surgically created dehiscence-type defects around titanium implants treated with an association of bone marrow-derived cells (BMCs) and guided bone regeneration (GBR). Bone marrow cells were harvested from eight male adult beagle dogs, cultured in vitro and phenotypically characterized with regard to their osteogenic properties. Following, the same animals were subjected to bilaterally teeth extraction (lower premolars and the first molar) and three months later, three implant sites were drilled in each side of mandible, buccal bone dehiscences were created and titanium dental implants with machined surface were placed. Dehiscences were randomly assigned to one of the following groups: 1) GBR+BMCs+C: PTFE-e barrier placement associated with BMCs into the carrier, 2) GBR+C: PTFE-e barrier placement associated with carrier, 3) GBR: PTFE-e barrier placement, 4) BMCs+C: BMCs into the carrier, 5) C: carrier without cells e 6) Control: no treatment. After 3 months, the animals were sacrificed and the implants in conjunction with adjacent hard tissues were processed for undecalcified sections. Bone-to-implant contact (BIC), bone filling within the limits of implant threads (BF) and new bone area (BA) in a zone lateral to the implant surface were obtained. Results: In vitro, phenotypic characterization demonstrated that BMCs presented osteogenic potential identified by the mineral nodule formation and the expression of bone markers. Histometrically, inter-group analysis demonstrated that all defects treated with GBR (GBR+BMCs+C, GBR+C and GBR) were statistically similar in terms of BA (p>0.05), presenting significantly higher BA as compared with other groups (BMCs+C, C and Control) (p<0.05). With respect the BF, no differences were observed among GBR+BMCs+C, GBR+C, GBR and BMCs+C groups (p>0.05), whereas all these groups showed statistically superior BF as compared to Control group (p<0.05). Additionally, although the percentage of BIC has been significantly higher in the defects treated by barrier membrane (GBR+BMCs+C, GBR+C and GBR) as compared to C and Control groups (p<0.05), a trend towards to a greater extension of BIC has been observed for the defects treated with BMCs+C. Within the limits of this study, it was concluded that although the use of bone marrowderived cells has provided promising outcomes in terms of bone formation within the limits of implant threads, their use, in combination with GBR, has not promoted additional benefits on the bone regeneration in peri-implantar dehiscence type bone defects. / Doutorado / Periodontia / Doutor em Clínica Odontológica
143

Avaliação da perda de pre-carga e infiltração bacteriana em sistemas de implantes de encaixe conico e hexagono externo / Evaluation of reload loss and bacterial penetration on conical and external hexagon connection implant systems

Ricomini Filho, Antônio Pedro, 1983- 12 April 2009 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:43:34Z (GMT). No. of bitstreams: 1 RicominiFilho_AntonioPedro_M.pdf: 1929547 bytes, checksum: 3218196794c582fbd092c07948036e16 (MD5) Previous issue date: 2009 / Resumo: A presença de microrganismos na interface implante e pilar é um dos fatores associado ao insucesso de implantes osseointegrados. Sistemas de implantes de encaixe cônico visam precisa adaptação entre o implante e o pilar, entretanto não se sabe o comportamento desses sistemas frente a condições de estresse da cavidade oral quanto à manutenção da pré-carga e capacidade de selamento bacteriano. Assim, o objetivo deste estudo foi avaliar a perda de précarga e a infiltração bacteriana na interface implante e pilar de sistemas de encaixe cônico e hexágono externo, submetidos à ciclagem térmica e fadiga mecânica (CF). Foram utilizados 48 implantes de quatro sistemas de implante-pilar divididos em 8 grupos (n=6): (1) hexágono externo e munhão universal; (2) hexágono externo e munhão universal com CF; (3) cone morse e munhão universal; (4) cone morse e munhão universal com CF; (5) cone morse e munhão universal parafuso passante; (6) cone morse e munhão universal parafuso passante com CF; (7) cônica justaposição e pilar padrão; (8) cônica justaposição e pilar padrão com CF. Os implantes foram fixados em resina epóxica e os pilares acoplados, realizando a pré-carga. Os espécimes (implante-pilar) foram submetidos à ciclagem térmica de 1.000 ciclos a 5°C e 55°C, com permanência de 60 s em cada banho, e à fadiga mecânica de 1,0 milhão de ciclos, 1,0 Hz e 120 N. O ensaio de infiltração bacteriana foi realizado com o microrganismo Streptococcus sanguinis (NCTC 10904). Os espécimes foram imersos em meio Tryptic Soy + Yeast Extract (TY) contendo S. sanguinis e incubados a 37°C e 10% CO2 por 72 h. Os valores de destorque foram registrados e os pilares foram desacoplados. Cone de papel estéril foi esfregado na parte interna do implante, inserido em um tubo contendo meio TY estéril e incubado. A presença de infiltração bacteriana foi avaliada por meio da turbidez do caldo. Implantes e pilares foram avaliados por meio de MEV. Os dados de perda de pré-carga foram submetidos à análise de variância a 2 critérios e ao teste de Tukey. Todos os sistemas apresentaram maiores valores de destorque quando submetidos à CF (p<0,05). O sistema cone morse com munhão universal apresentou os maiores valores de destorque quando comparado aos demais sistemas (p<0,01). Todos os sistemas cônicos apresentaram infiltração bacteriana. Dentro das condições experimentais, o sistema cone morse com munhão universal apresentou os maiores valores de destorque e não foi observado relação entre a perda da précarga e infiltração bacteriana. / Abstract: The presence of microorganisms in the implant and abutment interface is one of the factors associated to the osseointegrated implant failures. Conical junction implant systems have aimed a precise fit between implant and abutment, however, the behavior of these systems it is not known when submitted to the stress environment as found in the oral cavity, related to the preload maintenance and bacterial seal ability. Thus, the aim of this study was to evaluate the preload loss and the bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems, submitted to thermal cycling and mechanical fatigue (TM). Forty eight implants of four different implant-abutment systems were divided in 8 groups (n=6): (1) external hexagon and universal post; (2) external hexagon and universal post with TM; (3) morse taper and universal post; (4) morse taper and universal post with TM; (5) morse taper and universal post two pieces; (6) morse taper and universal post two pieces with TM; (7) locking taper and standard abutment; (8) locking taper and standard abutment with TM. The implants were embedded in epoxy resin and the abutments were connected, setting the preload. The assemblies (implant-abutment) were submitted to thermal cycling of 1.000 cycles at 5°C and 55°C, with a dwell time of 60 s each and to mechanical fatigue, 1.0 million cycles, 1.0 Hz, 120 N. Bacterial penetration assay was performed with Streptococcus sanguinis (NCTC 10904). The assemblies were immersed in Tryptic Soy + Yeast Extract (TY) broth containing S. sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded and the abutments were disconnected. Sterile paper points were rubbed on the inner part of the implant and inserted in a tube with sterile TY broth and incubated. The presence or absence of bacterial penetration was assessed by the broth turbidity. Implants and abutments were observed by SEM. The preload loss data was analyzed by two-way ANOVA, followed by Tukey test. All the screw systems showed higher detorque values when submitted to TM(p<0,05). The morse taper system with universal post showed the highest detorque values when compared with the other systems (p<0,01). All the conical systems showed bacteria penetration. Within these experimental conditions, the morse taper system with universal post showed the higher detorque values and no relation between the preload loss and the bacterial penetration was observed. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
144

Efeito da aplicação intermitente do PTH (1-34) sobre o tecido osseo ao redor de implantes inseridos em ratas expostas ou não a fumaça de cigarro / Effect of intermittent PTH (1-34) on bone tissue around implants in rats exposed or not to cigarette smoke inalation

Lima, Liana Linhares 15 August 2018 (has links)
Orientadores: Marcio Zaffalon Casati, João Batista Cesar Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T00:47:10Z (GMT). No. of bitstreams: 1 Lima_LianaLinhares_D.pdf: 1779418 bytes, checksum: 5170e97149f324c7dae9d9edd2c763fb (MD5) Previous issue date: 2009 / Resumo: O objetivo do presente estudo foi avaliar histometricamente a influência do PTH (1-34) sobre o reparo ósseo e osseointegração de implantes de titânio instalados em tíbias de ratas expostas ou não à inalação da fumaça de cigarro. Foram utilizadas 61 ratas Wistar adultas aleatoriamente divididas em: grupo 1 (n=15) : animais que receberam a aplicação do veículo necessário para a dissolução do hormônio após a instalação do implante; grupo 2 (n=16) : inalação de fumaça de cigarro (IFC) por 60 dias no pré e pós-operatório da colocação do implante; grupo 3 (n = 17): tratamento do grupo 2 associado à injeções subcutâneas de 40 fxg/kg de PTH sintético (1-34) três vezes por semana, após a colocação do implante e grupo 4 (n=13) : injeções subcutâneas de 40 Hg/kg de PTH sintético (1-34) três vezes por semana após a instalação dos implantes. Os animais foram sacrificados sessenta dias após a colocação dos implantes, secções não descalcificadas foram obtidas e avaliadas histometricamente, segundo os seguintes parâmetros: porcentagem de tecido ósseo em contato direto com a superfície do implante (CD), porcentagem de preenchimento ósseo das roscas do implante (AO) e porcentagem de tecido mineralizado numa zona de 500 um, adjacente à superfície do implante (PTM). Os parâmetros foram obtidos separadamente para região cortical e região medular. Não foram detectadas diferenças entre os grupos que receberam aplicação de PTH (1-34) (Grupos 3 e 4) em todos os parâmetros avaliados (p>0,05). Além disso, o PTH promoveu um aumento significativo no CD, AO e PTM em ambas as regiões, mesmo na presença de IFC (p<0.05) (exceto para AO na região cortical). Uma influência negativa da IFC foi observada para o parâmetro CD na região cortical, uma vez que o grupo 2 apresentou os menores valores de CD, seguidos do grupo 1. Resultados semelhantes foram observados para PTM em ambas as regiões analisadas. Dentro dos limites deste estudo pode-se concluir que a aplicação intermitente de PTH (1-34) é capaz de minimizar os impactos negativos da inalação da fumaça de cigarro na osseointegração de implantes de titânio inseridos em tíbias de ratas. / Abstract: The aim of this study was to investigate the synthetic parathyroid hormone, PTH (1-34), can mitigate the effect of cigarette smoke inhalation (CSI) on the bone healing around titanium implants inserted in rats. 61 female Wistar rats were randomly assigned to one of four groups: group l(n = 15): animals that received the application of the necessary vehicle for the dissolution of the hormone after installation of the implant; group 2 (n = 16): cigarette smoke inhalation (CSI) for 60 days preoperatively and sixty days after implant placement group 3(n = 17), treatment group 2, associated with subcutaneous injections of 40 u-g / kg of synthetic PTH (1-34) three times a week after implant placement and group 4 (n = 13): subcutaneous injections of 40 ug / kg of synthetic PTH (1-34) three times a week after placement of implants. The animals were sacrificed sixty days after the placement of implants, not decalcified sections were obtained and evaluated histometrically, according to the following parameters: percentage of bone tissue in direct contact with the implant surface (BIC), percentage of bone filling the threads of the implant (BF) and percentage of mineralized tissue in an area of 500 urn adjacent to the implant surface (BA). The parameters were obtained separately for the cortical and cancellous bone. No differences were found between the groups that received PTH (1-34) (Groups 3 and 4) in all evaluations (p> 0.05). In addition, PTH (1-34) caused a significant increase in BIC, BF and BA in both regions, even in the presence of CSI (p <0.05) (except for BF in the cortical region). A negative influence of the IFC was observed for the parameter BIC in the cortical region, as group 2 had the lowest values of BIC, followed by group 1. Similar results were observed for BA in both regions analyzed. Within the limits of this study can conclude that the intermittent application of PTH (1-34) is able to reversing the negative effects of cigarette smoke inhalation on osseointegration of titanium implants inserted in rats. / Doutorado / Periodontia / Doutor em Clínica Odontológica
145

Influencia da inclinação da mandibula em medidas do rebordo alveolar em exames de tomografia computadorizada de feixe conico para implantes / Cone beam computed tomography for dental implants : influence of the mandibular positioning on the bone height and widht

Menezes, Alynne Vieira de 06 August 2010 (has links)
Orientador: Solange Maria de Almeida / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T20:48:17Z (GMT). No. of bitstreams: 1 Menezes_AlynneVieirade_D.pdf: 1911461 bytes, checksum: 9eed499fb3fe7db23a7c4de2811423d3 (MD5) Previous issue date: 2010 / Resumo: A utilização de implantes dentários para a reabilitação de regiões edêntulas é uma das atividades mais crescentes da Odontologia e a utilização de imagens é um fator essencial para se alcançar o almejado sucesso. Vários métodos de imagem vêm sendo utilizados com esse propósito e a tomografia computadorizada de feixe cônico (TCFC) vem se estabelecendo como um dos métodos promissores nesse sentido, pois se trata de um método confiável, capaz de produzir imagens em tamanho real, sem sobreposição e com dose de radiação menor que a tomografia computadorizada fan beam. Neste trabalho teve-se como objetivo avaliar a influência da posição da mandíbula na realização de medidas da altura e da espessura de sítios implantares em cortes ortorradiais de TCFC. Para tanto, foram utilizadas 10 mandíbulas maceradas, sendo obtidas imagens utilizando-se o tomógrafo de feixe cônico i-CAT. Foi realizada uma única imagem de cada mandíbula e a partir dessa imagem, os cortes ortorradiais foram obtidos considerando-se 3 diferentes posições: 1: base da mandíbula paralela ao plano horizontal (Posição Normal - PN); 2: base com inclinação de +10° (Posição Superior - PS) e 3: com inclinação de -10° (Posição Inferior - PI). A altura e a espessura óssea de cada região foram mensuradas por um único examinador e os dados obtidos nos grupos experimentais (PS e PI) foram comparados com os dados obtidos do grupo controle (PN) usando a análise de variância two-way (a=0,05). Os valores médios de altura e de espessura ósseas não variaram significativamente entre as posições inclinadas (PS e PI) e a posição padrão (PN), o que permite concluir que nas inclinações avaliadas, a direção do plano axial não influenciou nas medidas obtidas / Abstract: Dental implants have became part of routine treatment plans in many cases of edentulous patients and an important part of preimplant examination is provided by images of the existing bone structures in addition to the clinical findings. Several imaging modalities have been used for preimplant assessment and the cone-beam computed tomography may indeed be the next major advancement, since provides clinicians with accurate images of high diagnostic quality with relatively short scanning times and a reported radiation dose lower than fan beam computed tomography. The aim of this present study was to investigate the influence of mandibular inclination on the measured height and width of the cortical bone in reformatted cross-sectional cone beam computed tomography. Ten human dry mandibles were scanned with dental CBCT (i-CAT). It was performed only one scan of any mandible and reformatted cross-sectional scans were obtained at three different positions: (1) parallel to the lower border of the mandible (standard position); (2) with a inclination of +10° (Upper Position) and (3) with a n inclination of -10°(Lower Position). The alveolar bone height and width were measured for one examiner and data subjected to two-way analysis of variance and to compare the means obtained for the experimental groups (UP and LP) with the control group (standard position) (a=0,05). Mean values of bone height and width did not varied significantly between the inclined (UP and LP) and the standard positions. It could be concluded that in the positions analyzed, the direction of the axial planes did not influence the measurements obtained / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
146

Avaliação in vitro da liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes.

Renata Bastos Del'Hoyo Fernandes 28 March 1996 (has links)
O objetivo deste estudo in vitro foi avaliar e comparar o padrão e a quantidade de liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes após períodos de 24 horas, 7 dias e 28 dias em água desionizada. Foram confeccionados 6 corpos de prova em forma de disco para cada material e cada período de leitura que, após a reação de endurecimento inicial, foram suspensos em recipientes plásticos contendo 18 mL de água desionizada. No momento da leitura, realizada a cada 6 horas no período de 24 horas, a cada 24 horas no período de 7 dias e a cada 7 dias no período de 28 dias, adicionou-se ao meio de armazenagem 2 mL de solução tampão TISAB III. A concentração de íons flúor em solução foi avaliada mediante leitura potenciométrica utilizando-se um aparelho analisador de íons. Vidrion C e XR Ionomer apresentaram as maiores quantidades de liberação de flúor. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I e Shofu I ocuparam uma posição intermediária e o Zionomer pó/líquido liberou a menor quantidade de flúor. Contudo, o padrão de liberação de flúor foi semelhante para todos os materiais testados. / The objective of the present in vitro study was to evaluate and compare the pattern and the quantity of fluoride release of lining and luting glass ionomer cements after 24 hours, 7 days and 28 days in de-ionized water. Six disc-shaped specimes were made for each material and for each reading period. After the initial hardening reaction, they were pierced and suspended in plastic containers with 18 mL of de-ionized water. Readings were carried out every six hours in the 24-hour period, every 24 hours in the 7- day period, and every 7 days in the 28-day period, when 2 mL of TISAB III buffer solution was added. The concentration of fluoride ions in solution was evaluated through potenciometric readings using an ion analyser device. Vidrion C and XR Ionomer showed the highest quantity of fluoride release. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I and Shofu I were intermediary in rank, whereas powder/liquid Zionomer released the least quantity of fluoride. However, the pattern of fluoride release was the same to all the tested materials.
147

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Carla Giannini Francischone 14 June 2006 (has links)
O objetivo deste trabalho foi: 1 - testar se existe alteração na resistência adesiva de dois cimentos utilizados na colagem de acessórios ortodônticos ao esmalte dental bovino, sendo um de polimerização química (Concise Ortodôntico) e outro fotpolimerizável (Transbond XT), após a aplicação de cargas contínuas, mediante testes de cisalhamento, 2 - observar se há diferença entre as cargas utilizadas e 3 - analisar o tipo de falha que ocorrida no momento do deslocamento dos braquetes para os dois cimentos testados. Foram utilizados para este estudo 80 dentes bovinos, 80 braquetes metálicos (Morelli Ortodontia - Braquete Edgewise/ Rickets para colagem), e pesos com 30g, 70g e 120g. O esmalte bovino foi condicionado com ácido fosfórico a 37% por 1 minuto e depois lavado e seco. A aplicação dos adesivos, manipulação e aplicação dos dois cimentos foram feitas de acordo com as instruções dos fabricantes. Para a padronização da espessura de cimento sob o braquete, foi utilizada uma Agulha Maior de Gilmore, posicionada sobre o braquete, de modo a fazer pressão durante a presa dos cimentos. Após 24 horas, os 80 braquetes colados com Concise e Transbond XT aos dentes foram submetidos às cargas contínuas de 30g, 70g e 120g, além do grupo controle onde os espécimes não receberam carga alguma, sendo 10 corpos de prova para cada teste. Os espécimes ficaram imersos em água filtrada por 28 dias dentro de uma estufa a 37°C. Depois deste período, as amostras foram submetidas a testes de cisalhamento em uma Máquina de Ensaios Universal Kratos, através de um dispositivo com alça metálica acoplado à célula de carga com 500kgf a uma velocidade de 0,5mm/min. Os resultados foram registrados e enviados para análise estatística dos resultados através do teste de Análise de Variância a dois critérios de classificação. Ficou concluído que: 1 - o cimento Concise apresentou maior resistência à remoção que o cimento Transbond XT para todas as cargas utilizadas, 2 - não houve diferença estatisticamente significante entre as três cargas utilizadas para os dois cimentos testados; 3 - com relação ao tipo de falha ocorrida no momento da fratura, conforme ocorreu o aumento da carga, a porcentagem de fratura do esmalte diminuiu para o Concise, ao contrário do cimento Transbond XT , onde a porcentagem de fratura de esmalte se manteve constante com o aumento das cargas. Os dois cimentos testados obtiveram resultados aceitáveis para a utilização clínica. / The aim of this study was: 1) to test differences on bond strength between auto-cured (Concise) and light-cured (Transbond XT) cements after static loading and shear test; 2) to observe whether differences exist among static loads and 3) to analyze failure mode after bracket displacement. Eighty bovine teeth and metallic orthodontic brackets (Morelli Ortodontia Braquete Edgewise/Rickets) were tested after static loads of 30, 70 and 120 grs. Bovine enamel was conditioned with 37% phosphoric acid gel for one minute, rinsed and dried. Adhesives were applied and brackets were bonded according to manufacturer\' s instructions. Cement thickness was standardized with the use of a heavier Gilmore needle. After 24 hours, half of the specimens were submitted to the static loads of 30, 70 and 120grs. Control groups remained unloaded. Then, specimens were immersed in distilled water for 28 days at 37oC. Afterwards, orthodontic brackets were attached to a loop wire and submitted to a shear force (Máquina de Ensaios Kratos Universal Kratos) under a crosshead speed of 0.5mm/min and load cell of 500Kgf. A two-way ANOVA test (?=0.05) was used to detect significant interactions between cements and static loads. It was concluded that: 1) The Concise cement showed more statistically significant bond strength values than the TransbondXT cement for all static loads; 2) No statistically significant differences were observed regarding static loads for all cements tested and 3) Higher static loads provided less enamel fracture in the Concise group after shear test, whereas in the Transbond XT the rate of enamel fracture remained unchanged regardless of previous load applied. The two tested cements provided acceptable results for clinical application.
148

Análise comparativa da adaptação marginal de componentes pré-fabricados e fundidos sobre pilares ceraone.

Lussara Azevedo Manhães 16 June 1999 (has links)
O critério mais importante para a aceitabilidade clínica de uma restauração indireta é o grau de adaptação marginal. Em próteses sobre implantes também torna-se necessária a obtenção de adequada adaptação marginal para a manutenção da saúde periimplantar e obtenção da longevidade da prótese. Avaliou-se “in vitro” a adaptação marginal na interface intermediário CeraOne(Nobel Biocare- Gotemburgo, Suécia) e cinco tipos de coifas: coifa cerâmica pré-fabricada CeraOne(DCA 127), In Ceram(Vita-Alemanha), coifa préfabricada poliacrílica do sistema CeraOne(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) e Fortune(Williams- Amherst, NY, Labordental-São Paulo). As coifas obtidas foram assentadas em um intermediário CeraOne(SDCA 334) e a adaptação marginal foi avaliada, segundo critérios de ajuste e desajuste marginal, em 6 pontos, determinados pelo sextavado do intermediário. De acordo com a análise estatística dos resultados, foi possível concluir que as coifas cerâmicas pré-fabricadas CeraOne(DCA 127) exibiram a maior quantidade de ajustes e os menores valores de desajuste, sendo consideradas a melhor opção restauradora sobre intermediários CeraOne. As coifas In Ceram apresentaram resultados muito satisfatórios, assim como as coifas IPS Empress. Esses dois sistemas são considerados aceitáveis para a utilização sobre intermediários CeraOne, como segunda opção e em casos selecionados. As coifas de porcelana fundida sobre refratário não exibiram resultados satisfatórios, quando comparadas aos demais grupos, sendo considerada uma técnica desaconselhável para ser utilizada sobre intermediários CeraOne. / The most important rule in the clinical acceptability of na indirect restoration is the marginal fit. Implant-supported restorations also need acceptable margins for the maintenance of peri-implant health and protheses longevity. The purpose of this study is to evaluate marginal fit of the abutment CeraOne(Nobel Biocare SDCA 334- Gotemburg, Sweden) “in vitro” as well as five kinds of ceramic caps: CeraOne prefabricated ceramic cap(DCA 127), In Ceram(Vita-Germany), CeraOne prefabricated polymethyl methacrylate cap(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) and Fortune(Williams- Amherst, NY, Labordental, São Paulo). The caps were seated on the CeraOne abutment and the marginal fit was examined under microscope according to the fit and misfit criteria in six faces around the margins. The results have shown that the best marginal fit was CeraOne prefabricated ceramic caps. This system is considered the first choice in the protocol for CeraOne restoration. The In Ceram and IPS Empress caps have presented satisfactory results, but IPS Empress has shown less fit and more discrepancy in comparison with In Ceram, probably due to the previous misfit of CeraOne prefabricated polymethyl methacrylate cap. These last two systems are considered acceptable to use in abutment CeraOne, but as a second option and in selected cases. The Fortune caps have not presented satisfactory results. Thus, this system is considered inadvisable for use with abutment implants.
149

Avaliação da hiperestesia dentinária após tratamento em diferentes formulações à base de oxalato de potássio utilizando-se um placebo como controle.

Ana Christina Bonato Figueiredo Martineli 24 June 1999 (has links)
A hiperestesia dentinária é uma das mais antigas queixas de desconforto dos pacientes e, devido à sua alta incidência e diversidade de tratamentos sugeridos na literatura, novos produtos devem ser avaliados quanto ao efeito e aplicabilidade. O propósito deste estudo foi avaliar as respostas imediata e mediata de 94 dentes (caninos e pré-molares), que apresentavam algum grau de sensibilidade dentinária (1, 2 ou 3) de acordo com a Escala de Medida Verbal (EMV) aos estímulos sonda e ar, após a aplicação de três formulações à base de oxalato de potássio: Oxa-Gel®, Solução Experimental 1 e Solução Experimental 2, tendo um placebo como controle. Cada formulação de oxalato de potássio e o placebo foram aplicados passivamente por 3 minutos na superfície da dentina úmida, sendo o excesso de material removido posteriormente. O grau de sensibilidade foi avaliado antes (baseline) e imediatamente após a aplicação de cada formulação com um intervalo de 7 dias. Os resultados obtidos após a quarta aplicação foram denominados resultados imediatos e, após 6 meses, resultados mediatos. Os escores foram submetidos à análise estatística através dos testes de Kruskal-Wallis e de Friedman two-way ANOVA (p< 0,05). A aplicação de todos os materiais, inclusive o placebo, independente do tempo avaliado e dos estímulos utilizados, resultou em uma redução estatisticamente significante na hiperestesia dentinária podendo essa redução prolongar-se até seis meses. Houve uma tendência de respostas mais severas ao estímulo ar quando comparado ao estímulo sonda antes do tratamento, sendo que a hiperestesia provocada pela sonda se mostrou mais persistente ao longo do tratamento. O tratamento da hiperestesia dentinária está sujeito a variáveis clínicas que podem aumentar ou diminuir o efeito anti-hiperestésico dos agentes estudados.
150

Efeito de duas diferentes rugosidades do intermediário de titânio no aspecto histológico do tecido peri-implantar de pacientes utilizando sobre-dentadura.

Sérgio Kiyoshi Ishikiriama 24 April 2000 (has links)
O sucesso da osseointegração depende, entre outros fatores, da integridade da interface entre os tecidos moles peri-implantares e componente intermediário do implante. Nesta região ocorre um vedamento que separa o meio interno e externo, responsável pela manutenção a longo prazo da osseointegração. Para que este mecanismo ocorra com êxito, é necessário que os tecidos moles possam exercer suas funções normais em um ambiente livre de inflamação e contaminação bacteriana. Levando-se em conta que os intermediários acumulam placa bacteriana devido à sua rugosidade superficial, o presente trabalho objetivou determinar a influência desta rugosidade na inflamação dos tecidos moles peri-implantares. Dois intermediários com diferentes rugosidades (intermediário padrão e polido) foram colocados em dez pacientes portadores de sobre-dentaduras inferiores, retidas por dois implantes do sistema NAPIO, desenvolvido na Faculdade de Odontologia de Bauru – USP, por um período de 3 meses. Após este período, biópsias foram realizadas e analisadas em microscópio de luz comum. A contagem morfométrica celular indicou que os tecidos moles peri-implantares ao redor dos intermediários polidos (grupo teste) apresentaram-se com uma quantidade média significantemente menor de linfócitos, quando comparados ao grupo controle (p<0.05). Portanto, a lisura superficial obtida no processo de polimento utilizado no presente trabalho foi considerada satisfatória no que tange a minimizar a inflamação dos tecidos moles peri-implantares e sugere-se que as superfícies dos intermediários devam ser o mais lisas possível no intuito de facilitar o controle de placa pelo próprio paciente. / The osseointegration success depends on the integrity of the interface between abutment and peri-implant soft tissues. In this region, a seal closes the opening between the oral mucosal and the implant, preventing the ingress of bacteria, plaque and other debris into the tissues of the internal environment and it is responsible for the long term maintenance of osseointegration. To acquire a complete seal, soft tissues must be free of inflammation and bacterial contamination. Since superficial roughness of abutments can facilitate the bacterial plaque accumulation, the aim of the present study was to determine the relation between abutment roughness and soft tissue inflammation. Abutments with 2 different levels of roughness (standard and polished abutment) were installed in 10 pacientes treated with mandibular overdentures anchored by 2 implants (NAPIO). After a period of 3 months, biopsies were removed and analyzed on a light microscope. The cell morfometric results showed that soft tissues around polished abutments harbored significantly less linfocytes than soft tissues around standard abutments. Therefore, the reduced superficial roughness presented on polished abutments successfully minimized the soft tissue inflammation and it is suggested that abutment surface should be as polished as possible to allowed a better plaque control by patients.

Page generated in 0.1615 seconds