• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Implantes zigomáticos na reabilitação do sistema estomatognático

Hochheim Neto, Ricardo January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catatina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T13:44:00Z (GMT). No. of bitstreams: 1 188419.pdf: 3441391 bytes, checksum: b6dddccf6f92978c31fa50da6f336c90 (MD5) / Os implantes zigomáticos são alternativas recentemente desenvolvidas para minimização de procedimentos cirúrgicos que necessitem de grandes enxertos ósseos em maxilas extremamente atrésicas com diminuição de tempo e morbidade dos procedimentos cirúrgicos e protéticos. Duas técnicas cirúrgicas serão comparadas a técnica convencional desenvolvida pelo Dr Per Ingvar Branemark(NOBEL BIOCARE),para chegarmos a conclusões neste trabalho de dissertação
272

Mensuração do calor friccional gerado pelo preparo do tecido ósseo em implantodontia

Andriani Júnior, Wilson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T13:51:28Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:40:00Z : No. of bitstreams: 1 182533.pdf: 3248629 bytes, checksum: df6bcf911d5984160dc71eb1f7cadfe2 (MD5) / O objetivo deste estudo in vitro foi desenvolver um dispositivo para avaliar o desempenho dos sistemas de irrigação interna e externa em implantodontia. A amostra foi composta de 20 espécimens ósseas de origem bovina. Dez espécimens foram submetidas a perfurações com as brocas do sistema 3i utilizando-se irrigação interna. Nas outras dez espécimens utilizou-se irrigação externa. Os resultados obtidos foram submetidos a tratamento estatístico. Na comparação individual das interações entre o tipo de broca e de irrigação testados, os resultados indicam que a broca 2,3 mm quando utilizada com irrigação externa provocou maior diferença de temperatura entre os momentos inicial e final , que todas as outras situações testadas. Dessa forma observou-se, neste estudo, que o sistema de irrigação interna gerou menor calor que o sistema de irrigação externa.
273

Adaptação marginal e resistência à fratura de coroas totais executadas em diferentes sistemas

Campos, Roberto Elias [UNESP] 08 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-08Bitstream added on 2014-06-13T19:20:25Z : No. of bitstreams: 1 campos_re_dr_ara_fo.pdf: 1412009 bytes, checksum: 89d711be988905ce8d1fbe919b64cafd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a adaptação marginal e a resistência à fratura de coroas totais metalocerâmicas e de coroas sem reforço de infra-estrutura metálica, utilizando-se diferentes sistemas restauradores. Foram selecionadas 48 raízes de dentes bovinos com diâmetros e formas semelhantes, seccionadas com 15 mm de comprimento. Após tratamento endodôntico e alívio do conduto pinos metálicos com 12 mm de comprimento foram fixados com cimento de fosfato de zinco e um preenchimento coronário de resina composta micro-híbrida foi construído com 3 mm de altura e convergência axial de aproximadamente 6 graus. O término cervical foi o ombro arredondado com 1,0 mm de largura. As amostras preparadas e seus respectivos modelos foram aleatoriamente distribuídos em 6 grupos com 8 amostras cada. As amostras foram, então, submetidas a carga de compressão em uma máquina de ensaios EMIC, a uma velocidade de 1 mm/min.. Após obtenção dos valores de resistência à fratura cada amostra foi submetida a uma inspeção visual na lupa estereoscópica para análise do modo de fratura. Para os valores de resistência à fratura, submetidos à análise estatística, o teste de Kruskall-Wallis acusou diferença significante e o teste U de Mann-Whitney indicou os locais de diferença. A análise do modo de fratura mostrou que o remanescente dental foi pouco afetado nas amostras dos grupos das coroas metalocerâmicas (Grupos A e B). Nos grupo C, D e E metade das fraturas ocorreu envolvendo somente o preenchimento coronário e a outra metade envolveu o preenchimento e a raiz do remanescente. O grupo F apresentou 100% de envolvimento do remanescente dental com fraturas cervicais ou longitudinais. Para os dados relativos à adaptação marginal o teste estatístico ANOVA não acusou diferença significante. Todos os grupos apresentaram valores dentro do limite de 100 æm, aceitável clinicamente. / The aim of this study was to evaluate the marginal adaptation and fracture resistance of metal-ceramic and metal-free prosthetic unit crowns made with different systems. Forty-eight bovine roots with 15 mm in length were used. After endodontic treatment a metallic post (12 mm) was fixed with zinc phosphate cement and a core of micro-hybrid resin was built up with 3 mm in height, round shoulder cervical termination with 1,5 in width and an approximate axial convergence of 6 degree. Fracture failure mode showed that subjacent structure were little affected in the specimens of metal ceramic groups (A and B). However, inside groups C, D and E half of the fractures involved only the core and the other half involved the core and the remaining dental root. The most catastrophic was the group F with 100% of dental remaining involved, showing cervical and longitudinal fractures in the roots. For marginal adaptation Analysis of Variation (p<0,05) showed no differences among all groups. Means of each group were: A - (74 æm); B (102 æm); C (87 æm); D (99 æm);E (80 æm); F (100 æm). All groups had marginal gap within 100 æm, clinically accepted.
274

Resistência e tipo de falha de união de materiais retrobturadores

Vivan, Rodrigo Ricci [UNESP] 25 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-25Bitstream added on 2014-06-13T20:02:14Z : No. of bitstreams: 1 vivan_rr_dr_arafo.pdf: 430718 bytes, checksum: c8daef7f0f4f6cc368db08a274fe12ea (MD5) / O presente estudo avaliou a resistência e tipo de falha de união de materiais retrobturadores à parede do canal radicular por meio do teste push-out. Capítulo 1 - Foi realizada comparação da resistência de união por compressão (push-out) e tipo de falha dos materiais retrobturadores MTA Angelus, MTA Sealer, Sealer 26 e OZE. Foram utilizadas 40 fatias de 2 mm de espessura de dentes unirradiculados humanos. Após preparo inicial do canal radicular com broca cilíndrica com 1,5 mm de diâmetro, o preparo retrógrado foi confeccionado com ponta de ultrassom CVD T0F-2. Os corpos-de-prova foram divididos aleatoriamente em 4 grupos (n=10) de acordo com o material retrobturador: Grupo 1: MTA Angelus; grupo 2: MTA Sealer; grupo 3: Sealer 26; grupo 4: OZE. Para o teste, cada espécime foi posicionado na máquina de ensaios mecânicos (EMIC DL 2000) com velocidade de 1mm/min e célula de carga de 5kN, para a realização do teste de push-out. Também foi avaliada a presença dos cimentos nas paredes radiculares por meio do microscópio confocal de varredura a laser, e análise do tipo de falha em estereomicroscópio. Os dados foram submetidos ao teste estatístico de ANOVA e Tukey, com nível de significância de 5%. Os resultados de push-out mostraram maior adesão para MTA Angelus (19,18 MPa) e MTA Sealer (19,13 MPa), seguidos do Sealer 26 (15,91 MPa). O cimento OZE (9,50 MPa) apresentou menor adesão que os demais cimentos estudados, com diferença estatisticamente significante (p<0,05). Em relação a presença de cimento, o cimento OZE (89,77%) e o MTA Sealer (83,06%) apresentaram os maiores valores, seguidos pelo Sealer 26 (59,33%), sem diferença significante entre os materiais (p>0.05). Em relação ao tipo de falha, predominou a falha adesiva, com exceção do grupo 4 (OZE), onde predominou a falha mista. Conclui-se que os materiais... / The aim of study was to evaluate the bond strength and failure type to root-end filling materials wall by means of push-out test. Chapter 1 – the aim of this study was to evaluate the bond strength and failure type of root-end filling materials MTA Angelus, MTA Sealer, Sealer 26 and OZE. 40 slices were used 2 mm thick of human teeth. After initial root canal preparation with cylindrical drill with 1.5 mm in diameter, the root-end preparation was made with ultrasound tip CVD T0F-2. The specimens were randomly divided into 4 groups (n=10) according to the root-end filling materials: Group 1: MTA Angelus; Group 2: MTA Sealer; Group 3: Sealer 26; Group 4: OZE. For the test, each specimen was positioned in the mechanical testing machine (EMIC DL 2000) with 1mm/min speed and load cell of 5KN to the completion of the push-out test. It was also evaluated the presence of cement through the confocal scanning laser microscope and analysis of failure type in stereomicroscope. The data were submitted to ANOVA and Tukey test statistic with significance level of 5%. The results of push-out showed greater bond strength to MTA Angelus (19,18 MPa) and MTA Sealer (19,13 Mpa), followed the Sealer 26 (15,91 Mpa). OZE (9.50 Mpa) showed lower accession than other materials, with statistically significant (p 0.05). In relation to presence of cement, the OZE (89.77%) and the MTA Sealer (83.06%) showed the greatest values, followed by Sealer 26 (59.33%), no significant difference between the materials (p> 0.05). In relation to the type of failure, predominated the adhesive failed, with the exception of Group 4 (OZE), which predominated the coesive failure. It is concluded that the MTA Angelus, MTA Sealer and Sealer 26 exhibit bond strength as root-end filling materials. Chapter 2 – the aim of this study was to evaluate... (Complete abstract click electronic access below)
275

Nanocompósito de alumina com inclusão nonométricas de zircônia para infraestruturas de próteses odontológicas livres de metal: avaliação de prosperidades mecânicas e análise microestrutural. -

Pierri, Juliano de [UNESP] 29 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-29Bitstream added on 2014-06-13T19:05:07Z : No. of bitstreams: 1 pierri_j_dr_arafo.pdf: 3628153 bytes, checksum: fa1a39047c990b824665426ff4169b19 (MD5) / As próteses cerâmicas sem metal têm sido cada vez mais utilizadas em função das vantagens apresentadas, como biocompatibilidade, resistência à compressão, estabilidade de cor, radiopacidade e baixa condutibilidade térmica e elétrica. O potencial desses materiais em mimetizar os tecidos dentais também tem contribuído para aumentar sua indicação, atendendo a crescente exigência estética dos pacientes. Apesar dessas características favoráveis, percentuais consideráveis de insucesso clínico têm sido observados, demonstrando que as propriedades mecânicas dos materiais utilizados ainda precisam ser melhoradas. Uma alternativa ainda pouco explorada na odontologia é a utilização de inclusões nanométricas como reforço em matriz também cerâmica, obtendo-se os nanocompósitos cerâmicos. Assim, o objetivo do presente estudo foi avaliar as propriedades de dureza, tenacidade e limite de resistência à fadiga flexural de nanocompósito denso de matriz de alumina com inclusões nanométricas de zircônia, visando sua aplicação em infraestruturas de próteses odontológicas livres de metal. As amostras foram produzidas seguindo metodologia estabelecida em estudos anteriores, que consiste nas seguintes etapas: 1) mistura das matérias primas por meio de desaglomeração da alumina pura e da ZrO2 nanométrica em moinho de bolas convencional; 2) adição da suspensão contendo as partículas nanométricas com a alumina por gotejamento contínuo da suspensão alcóolica de ZrO2 e mistura em moinho de bolas convencional; 3) secagem dos pós no interior do moinho de bolas, sob agitação, em temperatura próxima da ambiente, com auxílio de fluxo de ar perpendicular à abertura do frasco de moagem; 4) preparo das amostras com a mistura obtida, aplicando-se prensagem uniaxial (50 MPa), seguida de prensagem isostática... / Metal free prosthesis became popular because of the advantages presented by the ceramic materials, such as biocompatibility, compressive strength, color stability, radiopacity and low thermal and electrical conductivity. The potential of these materials to mimic the dental tissues and the patient’s demand for aesthetic treatments have also contributed to their increased popularity. Despite these favorable characteristics, considerable percentage of clinical failure has been observed, demonstrating that their mechanical properties still need improvements. An alternative yet little explored in dentistry is the use of nanometric inclusions as reinforcement, resulting in ceramic nanocomposites. Thus, the objective of this study was to evaluate the hardness, toughness and flexural fatigue properties of a nanocomposite comprised of alumina matrix reinforced with nano-inclusions of zirconia, expected to be used as infrastructure for metal-free prosthesis. The samples were produced following the method established in a previous study, which consists of the following steps: 1) mixture of pure alumina and nano-ZrO2 powders in conventional ball mill, 2) addition of the suspension containing the particles with nanometric alumina suspension by continuous drip of ZrO2 and mixing in conventional ball mill, 3) drying the powder inside the ball mill, stirred at ambient temperature, with the aid of air flow perpendicular to the opening of the bottle crushing; 4) sample preparation applying a uniaxial (50 MPa), followed by isostatic pressing (200 MPa). The samples were made in prismatic form (25 X 5 X 2 mm) for flexural fatigue test (n = 30) and disc-shaped (chips) with 10 mm diameter and 5 mm thickness for testing toughness and hardness (n = 10); 5) removal of organic components added during the preparation of powders and... (Complete abstract click electronic access below)
276

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever

Mesquita, Alfredo Mikail Melo [UNESP] 30 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-30Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 mesquita_amm_dr_sjc.pdf: 511472 bytes, checksum: bdcad35472f1cab510c82684030d9a0f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn’t difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated.
277

Avaliação da retençao de coroas de Ytrio-zircônia cimentadas à diferentes substratos, com quatro agentes cimentantes, após termociclagem

Amaral, Regina [UNESP] 02 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-02Bitstream added on 2014-06-13T19:24:15Z : No. of bitstreams: 1 amaral_r_dr_sjc.pdf: 474843 bytes, checksum: ec47413ee9365a7ca21114ff7253d659 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve a finalidade de avaliar o efeito do tipo de substrato coronário (dentina e resina composta) na retenção de coroas cerâmicas de zircônia estabilizada por óxido de ítrio e comparar a retenção em função de diferentes protocolos. Para tanto, 144 molares recém-extraídos foram embutidos em resina acrílica, perpendicular ao seu longo eixo e preparados para coroa total, 72 permaneceram com o preparo em dentina e os demais, a parte coronária preparada foi removida e reconstruída em resina composta + pinos de fibra com dimensões idênticas à dentina preparada. Os preparos foram moldados com silicona de adição e dos troqueis foram obtidos 144 copings em YTZP, os quais apresentaram uma configuração especial para o ensaio de tração. Para ambos substratos, foi utilizado como grupo controle (n=12) um cimento à base de fosfato de zinco (sem condicionamento do substrato e da cerâmica). Os outros cimentos utilizados foram: um cimento à base de ionômero de vidro, um cimento resinoso da geração auto-condicionate (ambos sem condicionamento do substrato e da cerâmica) e um cimento Dual contendo monômeros fosfatados (MDP). Neste ultimo grupo, os remanescentes (dentina ou resina) foram condicionados com o adesivo correspondente do sistema e a cerâmica foi submetida a 3 tratamentos de superfície: álcool isopropílico, silicatização/silanização ou Vitrificação. Após 24h, todos os conjuntos foram submetidos a termocilagem (6000 ciclos) e incluídos em um dispositivo especial para o teste de tração em uma máquina de ensaio universal, para testar a retenção das infra-estruturas. Os modos de falha de todos os conjuntos foram analisados em estereomicroscópio e MEV para avaliar... / The aim of this study was to evaluate the effect of the crown substrate type (dentine and composite resin) in the retention of stabilized zirconia ceramic crowns by yttrium oxide (YTZP) and to compare the retention function of four types of cements, four treatments of the substrate surface and three treatments of the ceramic surface. For this purpose, 144 freshlyextracted molars were embedded in acrylic resin, perpendicular to the long axis and prepared for full crowns, 72 remained with the preparation in dentin and the other, the crown part was removed and reconstructed with composite resin + fiber pins with dimensions identical to the prepared dentin. The preparations were moulded with addition silicone and 144 YTZP copings were obtained, which presented a special setup for the tensile test. For the remainin, a phosphate-based cement zinc (unprimed substrate and ceramics) (n = 12) was used as the control group. The other used cements were: a glass-ionomer based cement, a resin cement from self-condicionating generation (unprimed substrate and ceramic) and a Dual cement containing phosphate monomer. In the latter groups, the remaining (dentin or resin) was conditioned with the adhesive system and the corresponding ceramic was subjected to three surface treatments: isopropyl alcohol, silica coating / silanization or Overglaze. After 24 hours, all sets were submitted to thermocycling (6000 cycles) and included in a special device for the tensile test in a universal testing machine to test the retention of the infrastructure. The failure modes of all sets were analyzed under a stereomicroscope and SEM to evaluate possible causes of failure. Data was analyzed statistically. The results showed that in dentin, the glass-ionomer... (Complete abstract click electronic access below)
278

Influência da deposição de filmes de carbono tipo diamante na infiltração bacteriana pela interface entre implantes e pilares protéticos

Cardoso, Mayra [UNESP] 18 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-18Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 000758225.pdf: 2964831 bytes, checksum: 9dd38178e41e4dfce4ae833a7c0c3ca4 (MD5) / O estudo avaliou a influência da deposição de filmes de DLC na infiltração bacteriana pela interface entre pilares protéticos e implantes de hexágono externo (HE) e interno (HI). Também avaliou a aderência microbiana a estes filmes, depositados sobre titânio. A deposição dos filmes foi realizada por PECVD (Deposição Química a Vapor Assistida por Plasma), e sua caracterização foi feita pelas análises de perfilometria mecânica, espectroscopia Raman, rugosidade, análise tribológica, espectroscopia de energia dispersiva e ângulo de contato. Para avaliação da aderência microbiana, lâminas de titânio (N=45; n=15) foram divididas em três grupos: (1) sem filme (controle); (2) com filme de DLC; e (3) com filme de DLC dopado com prata (DLC-Ag). Elas foram suspensas em poços contendo saliva-glicerol e caldo de cultura. Após 48 h de incubação, elas foram agitadas em ultrassom e a suspensão resultante foi diluída e semeada em placas para contagem de microrganismos. Para avaliação da infiltração bacteriana pela interface implante/pilar, conjuntos de implantes e pilares HE e HI (N=180; n=30) foram divididos de acordo com o tratamento da base do pilar: (1) nenhum tratamento (controle); (2) deposição de filme de DLC; e (3) deposição de filme de DLC-Ag. Sob condições assépticas, foi inoculado 1 μL de suspensão de Enterococcus faecalis no interior dos implantes, e os pilares foram parafusados com 20 Ncm. Os conjuntos foram testados para contaminação externa imediata, suspensos em tubos de ensaio contendo caldo de cultura estéril, e acompanhados por cinco dias. A turvação do caldo indicou infiltração bacteriana. Ao final do período, os pilares foram desparafusados e o conteúdo interno dos implantes foi coletado com cone de papel e semeado em placas de Petri. Estas foram levadas a estufa bacteriológica por 24 h para verificação da viabilidade bacteriana.... / This study evaluated the influence of DLC films on bacterial leakage through the interface between abutments and dental implants of external hexagon (HE) and internal hexagon (HI). It also evaluated microbial adhesion to these films deposited on titanium. The deposition of the films was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition), and its characterizations were done by mechanical profilometry, Raman spectroscopy, surface roughness, tribological analysis, energy dispersive spectroscopy and contact angle. To evaluate the microbial adhesion, titanium blades (N=45, n=15) were divided into three groups: (1) without film (control), (2) with DLC film, and (3) with DLC film doped with silver (Ag-DLC). They were suspended in wells containing saliva-glycerol broth. After 48 h incubation they were ultrasonicated and the resulting suspension was diluted and plated for CFU counting. For evaluation of bacterial leakage through implant/abutment interface, sets of implants and abutments (N=180, n=30) were divided according to the treatment of the base of the abutment: (1) no treatment (control); (2) deposition of DLC film, and (3) deposition of Ag-DLC film. Under aseptic conditions, 1 μL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened to 20 Ncm. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for five days. The turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper cone and seeded in Petri dishes. These were incubated for 24 h for assessment of bacterial viability and CFU counting. The roughness and log10CFU/mL data were analyzed by analysis of variance. The bacterial leakage was analyzed by Chi-square test, Fisher exact test, Kaplan-Meier and ....
279

Propriedades físico-químicas e mecânicas, potencial bioativo e caracterização da interface dentina-cimento de cimentos endodônticos experimentais à base de cimento Portland associados à radiopacificadores micro e nanoparticulados / Physicochemical and mechanical properties, bioactivity potential and characterization of the dentin-sealer interface of experimental root sealers based on portland cement with micro and nano particulate radiopacifiers

Viapiana, Raqueli [UNESP] 27 March 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-27Bitstream added on 2015-04-09T12:47:35Z : No. of bitstreams: 1 000806823.pdf: 4815535 bytes, checksum: 8a928ad2b8e79998a887a16919911289 (MD5) Bitstreams deleted on 2015-04-23T11:39:26Z: 000806823.pdf,Bitstream added on 2015-04-23T11:39:58Z : No. of bitstreams: 1 000806823_20170327.pdf: 566845 bytes, checksum: 5251321f73ff5631ce7c00ef0c2f738e (MD5) Bitstreams deleted on 2017-03-31T12:19:27Z: 000806823_20170327.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:23Z : No. of bitstreams: 1 000806823.pdf: 4815535 bytes, checksum: 8a928ad2b8e79998a887a16919911289 (MD5) / O cimento Portland é constituído por silicato de cálcio e a associação com aditivos e veículos conferem características que podem viabilizar seu uso como cimento endodôntico. No entanto, o cimento Portland não apresenta radiopacidade própria, o que torna necessário a adição de um agente radiopacificador à mistura para ser utilizado como material dentário. O objetivo deste estudo foi avaliar as propriedades físico-químicas e mecânicas, o potencial bioativo e caracterizar a interface dentina-cimento de cimentos endodônticos experimentas à base de cimento Portland (ES) contendo nano ou micro partículas de óxido de zircônio ou óxido de nióbio. O tempo de presa, resistência à compressão, escoamento, espessura de filme, radiopacidade, solubilidade e estabilidade dimensional foram avaliadas de acordo com a norma ISO 6876:2012, enquanto que a liberação de fomaldeído foi avaliada por meio de cromatografia gasosa. A resistência de união dentinária foi avaliada por meio de teste push-out e tanto a caracterização da microestrutura dos cimento quanto a análise do potencial bioativo foram realizadas utilizando energia dispersiva de raios-x, difractometria e espectroscopia infravermelha. A interface dentina-cimento foi avaliada com relação à penetração de microesferas fluorescentes e examinada em microscopia confocal e microscopia eletrônica de varredura associada à escaneamento por energia dispersiva de raios-x linear. Os dados foram submetidos aos testes ANOVA e Tukey (p < 0,05). Com exceção da radiopacidade, os ES apresentaram propriedades físico-químicas de acordo com as especificações ISO 6876, adequada resistência de união à dentina, potencial bioativo e promoveram selamento coronário e interação química com a dentina. / Portland Cement is composed by calcium silicate and the association with additives or vehicles, may confer characteristics to enable the use of this cement as root canal sealer. However, Portland cement lacks in radiopacity which requires the addition of a radiopacifying agent to the mixture to be used as dental material. The purpose of this study was to assess the physicochemical and mechanical properties, the bioactivy potential and to characterize the dentin-sealers interfaces of Portland-based experimental root canal sealers (ES) containing nano or micro particles of zirconium oxide or niobium oxide. Setting time, compressive strength, flow ability, film thickness, radiopacity, solubility and dimensional stability were evaluated according to ISO 6876:2012 standards, whereas formaldehyde realease was investigated using gas-cromatography. Dentin bond strength was evaluated by push-out test and the sealer’s microestruture and bioactivity potential were perfomed using X-ray energy espectroscopy, X-ray diffractometry and infrared spectroscopy. Dentin-sealers interface was assessed with respect to fluorescent microspheres penetration and it was also examined using confocal microscope and scanning electron microscope coupled to X-ray energy dispersive line scans. Data were analyzed by ANOVA and Tukey post-hoc test (p < 0.05). With the exception of radiopacity, ES showed physicochemical properties according to ISO 6876:2012 specifications, adequate dentin bond strength, great bioactivity potential and promoted coronal sealing and chemical interaction with dentin.
280

Sobrevivênvia e sucesso de implantes osseointegrados com superfície tratada por ataque ácido: avaliação retrospectiva de 8 a 10 anos

Nícoli, Lélis Gustavo [UNESP] 24 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-24Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000798064.pdf: 1338097 bytes, checksum: 4e73f39cb79767bd4dca8a67d9f1405d (MD5) / Implantes dentários com superfície tratada por ataque ácido representam uma opção clínica para a reabilitação de regiões edêntulas. No entanto, trabalhos prévios mostram que uma variedade de fatores de risco pode comprometer a longevidade do implante. O objetivo deste estudo foi avaliar retrospectivamente a taxa de sobrevivência e sucesso de implantes com superfície tratada por ataque ácido. A amostra constituiu-se de 183 implantes instalados em 44 pacientes que foram submetidos à reabilitação protética no período de 2003 a 2005. A idade média dos pacientes no momento da instalação dos implantes foi de 50 anos, sendo 18 pacientes do gênero masculino e 26 do gênero feminino. Após exames clínico e radiográfico, foi verificado que apenas 5 implantes (2,7%) foram perdidos em 4 pacientes, 1 na maxila e 4 na mandíbula, e 3 implantes (2,0%) não estavam em função. Dos implantes presentes, 155 (87%) aderiram aos critérios de sucesso e 20 (11%) apresentavam peri-implantite. Os pacientes foram reabilitados com próteses múltiplas e unitárias do tipo parafusadas ou cimentadas. Dentre as reabilitações protéticas, implantes com próteses múltiplas parafusadas apresentaram uma maior porcentagem de peri-implantite (15,3%). Baseado nestes resultados, implantes com superfície tratada com ataque ácido apresentaram uma taxa de sobrevivência de 97% e uma taxa de sucesso de 85% após um período de 8 a 10 anos em função. / Rough-surface dental implants are a viable clinical alternative for rehabilitation of edentulous areas. However, previous studies have suggested that a vast array of risk factors may compromise the long-term success rate of dental implants. This retrospective study aimed to evaluate the survival and the success rates of dental implants with an acid-etched surface. 183 implants were performed in 44 patients who received subsequent implant-supported prosthetic treatment between the years of 2003 and 2005. Patient mean-age at the time of implant placement was 50 years. 18 patients were male and 26 female. Clinical and radiographic examination showed that only 5 implants (2,7%) were lost among 4 patients, 1 in the maxilla and 4 in the mandible and that 3 implants (2,0%) were not in function. 155 (87%) of the functioning implants fell under the success criteria employed whereas 20 (11%) of them presented peri-implantitis. Rehabilitation included screw-retained or cemented single crowns and bridges. A higher prevalence of peri-implantitis (15.3%) was noted for screw-retained bridges. Results showed a survival rate of 97,3% and a success rate of 87% for dental implants with an acid-etched surface after 8 to 10 years of loading.

Page generated in 0.0455 seconds