• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Efeito da remoção de colágeno na resistência de união de cimentos resinosos à dentina / Effect of dentin deproteinization on bond strength of resin cements to dentin

Souza, Lidiane Costa de January 2013 (has links)
SOUZA, Lidiane Costa de. Efeito da remoção de colágeno na resistência de união de cimentos resinosos à dentina. 2013. 42 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2013-11-22T10:59:44Z No. of bitstreams: 1 2013_dis_lcsouza.pdf: 494069 bytes, checksum: 3109e08bbcc1225683d8f99adf329e66 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-11-22T11:00:43Z (GMT) No. of bitstreams: 1 2013_dis_lcsouza.pdf: 494069 bytes, checksum: 3109e08bbcc1225683d8f99adf329e66 (MD5) / Made available in DSpace on 2013-11-22T11:00:43Z (GMT). No. of bitstreams: 1 2013_dis_lcsouza.pdf: 494069 bytes, checksum: 3109e08bbcc1225683d8f99adf329e66 (MD5) Previous issue date: 2013 / Introduction: The self-adhesive resin cements have been introduced to the market in order to reduce the clinical steps and, thus, reducing the operative time and sensitivity. Although the concept of one-step applying be very attractive, some studies show limitations of resin cements concerning the potential of demineralization and superficial interaction with the dentin. Objective: To evaluate the effect of removing dentin collagen with 5% NaOCl on the bond strength of resin cements/dentin interface. Methods: Thirty-two freshly extracted third molars were sliced to expose sound dentin, to remove the roots and were randomly divided into four groups according to the type of cement used (conventional or self-adhesive) and strategy of cementing used: RelyX ARC/Single Bond 2 applied following the manufacturer´s instructions – control (RAc), RelyX ARC/Single Bond 2 applied on deproteinized dentin (RAd); RelyX U200 applied following the manufacturer´s instructions – control (RUc); RelyX U200 applied on deproteinized dentin (RUd). Blocks of composite resin were cemented on dentin surface and the specimens were prepared for microtensile bond test. The sticks of each group were subdivided into two subgroups: immediate test and test after 20,000 thermal cycles. Results: Three-way Anova showed that collagen removal increased the bond strength values for both cements, although the RAd group showed a decrease in the bond strength values after thermocycling. Chi-square test showed significant increase of premature failures for the groups, except for the group of RUd. Conclusion: The collagen removal improved the immediate bond strength for both cements tested, but, after thermocycling, this union was preserved only in the RelyX U200 group. / Introdução: Os cimentos resinosos autoadesivos foram introduzidos no mercado a fim de reduzir os passos clínicos e, assim, diminuir o tempo e a sensibilidade operatória. Apesar de o conceito de aplicação única ser bastante atrativo, alguns estudos mostram limitações desses materiais no que se diz respeito ao potencial de desmineralização e interação superficial com a dentina. Objetivo: Avaliar o efeito da remoção de colágeno dentináro com NaOCl a 5% na resistência de união da interface formada entre cimentos resinosos e a dentina. Metodologia: Trinta e dois terceiros molares recém- -extraídos tiveram a dentina coronária exposta, as raízes removidas e foram divididos aleatoriamente em quatro grupos de acordo com o tipo de cimento (convencional ou autoadesivo) e com a estratégia de cimentação utilizada (manutenção ou remoção de colágeno da dentina): RelyX ARC/Single Bond 2 aplicado de acordo com a recomendações do fabricante - controle (RAc); RelyX ARC/Single Bond 2 aplicado após a remoção de colágeno (RAd); RelyX U200 aplicado de acordo com a recomendações do fabricante - controle (RUc); RelyX U200 aplicado após a remoção de colágeno (RUd). Blocos de resina compostas foram cimentados sobre a superfície dentinária e os espécimes foram seccionados para o teste de microtração. Os palitos de cada grupo foram subdivididos em dois subgrupos: teste imediato e teste após 20.000 ciclos térmicos. Resultado: O teste Anova mostrou que a remoção de colágeno aumentou os valores de resistência de união para ambos os cimentos, embora, para o grupo RAd, houve um decréscimo nos valores de resistência de união para os palitos termociclados. O teste qui-quadrado mostrou um significante aumento de falhas prematuras para os grupos, exceto para o grupo RUd. Conclusão: A remoção de colágeno melhorou a resistência de união imediata para os materiais testados, mas só ocorreu preservação desta união, após termociclagem, quando o RelyX U200 foi utilizado.
252

Fatores potenciais relacionados à perda óssea peri-implantar

Souza, João Gustavo Oliveira de January 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:46:50Z (GMT). No. of bitstreams: 1 324680.pdf: 1343086 bytes, checksum: c3cb2856b00deb91deb9acdaf6dc24b3 (MD5) Previous issue date: 2013 / O objetivo do estudo foi avaliar a associação de fatores sistêmicos e características da reabilitação implantossuportada - implante, prótese e parâmetros clínicos - na perda óssea peri-implantar adicional = 2mm (POA). Foram selecionados para o estudo 297 pacientes, reabilitados com 1001 implantes por pelo menos 1 ano. Os efeitos de diversas variáveis potencialmente explicativas foram avaliados segundo condição sistêmica do paciente, e características do implante, prótese e parâmetros clínicos. A regressão logística não demonstrou associação de fatores sistêmicos na POA. Houve correlação estatística positiva para POA na carga mediata (p<0,001), superfície usinada (p=0,007) e implantes em função por mais de 4 anos (p<0,001), no nível de implantes. Próteses cimentadas (p=0,008) e próteses múltiplas (p<0,001) apresentaram maiores valores de POA. Na análise dos parâmetros clínicos, maior POA foi observada nos implantes que apresentaram biofilme adjacente (p<0,001), além de maiores valores de recessão marginal (RM) (p<0,001) e profundidade clínica de sondagem (PCS) =5mm (p<0,001). Pode-se concluir que nenhum fator sistêmico influencia a POA. Carregamento imediato, tratamento superficial dos implantes e implantes com menos tempo em função parecem favorecer a manutenção óssea. A POA está associada a próteses cimentadas e múltiplas, assim como presença de biofilme adjacente ao implante e maiores valores de RM e PCS =5mm. Logo, pacientes com tais questões devem ser informados sobre risco de POA, previamente à terapia com implantes, e comparecer, periodicamente, às consultas de manutenção.<br> / Abstract : The aim of the study was to retrospectively evaluate the association of systemic factors and implant-supported rehabilitation features - implant, prosthesis and clinical parameters - with additional peri-implant bone loss = 2mm (ABL). For this study, there were selected 297 patients rehabilitated with 1001 implants at least 1 year in function. The effects of several potentially explanatory variables were evaluated according patient?s systemic conditions and implant, prosthesis and clinical parameters? features. Logistic regression did not demonstrate any association of systemic factors in ABL. There was a positive statistical correlation for ABL in immediate loading (p<0,001), machined surface (p=0,007) and implants in function for more than 4 years (p<0,001) - implant level. Cemented prosthesis (p=0,008) and multiple prostheses (p<0,001) presented higher values for ABL. For clinical parameters analysis, higher ABL was observed in implants that presented adjacent biofilm (p<0,001), higher values of marginal recession (MR) (p<0,001) and clinical probing depth (PD) =5mm (p<0,001). No systemic factor influences ABL. Immediate loading and surface treatment favor the maintenance of peri-implant bone. Also, ABL is associated with cemented prosthesis; partial dentures; and implants in function for more than 4 years. Moreover, with the presence of adjacent biofilm and higher values of MR and PD =5mm. Hence, patients with such issues should be informed about the risk of ABL, prior to implant therapy, and attend periodically to maintenance consultations.
253

Avaliação de diversos tipos de transferentes para prótese sobre implante

Andrade, Pâmela Cândida Aires Ribas de January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T17:57:10Z (GMT). No. of bitstreams: 1 327225.pdf: 4476966 bytes, checksum: 9afe1770eacf4599c637b70373a02e3d (MD5) Previous issue date: 2014 / A reprodução precisa da posição tridimensional (3D) do implante é um fator decisivo no estabelecimento de uma prótese ajustada e passiva. Vários fatores podem influenciar na precisão de uma moldagem de transferência sobre implante, e o desenho do transferente pode ser um deles. OBJETIVO: O objetivo deste estudo foi analisar quatro desenhos diferentes de transferente e comparar a precisão da moldagem de transferência de implantes unitários realizada por eles. MATERIAL E MÉTODOS: Um modelo metálico com quatro implantes hexágono externo foi desenhado e fabricado para a realização de vinte moldagens pela técnica da moldeira aberta. As moldagens foram realizadas com todos os tipos de transferentes (n=10) (transferente convencional [TC], transferente modificado com dois parafusos laterais [TMP], transferente modificado e sem parafusos laterais [TM], transferente modificado com resina acrílica [TR]); e duas situações (S1: n=20 e S2: n=20) de espaço 3D envolvendo dente e implante também foram avaliadas. As moldagens foram vazadas com gesso especial tipo IV e a precisão da posição 3D dos análogos foram avaliadas utilizando uma Máquina de Medir por Coordenadas (MMC). As medições (deslocamento linear, angular e rotacional) foram comparadas com as medições calculadas no modelo metálico. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e pelo teste t de student. RESULTADOS: Os resultados mostraram que (1) não existiu diferença estatisticamente significante entre os diferentes tipos de transferente para as duas situações analisadas; e (2) na comparação entre S1 e S2 o TC deslocou e rotacionou na S2. CONCLUSÃO: A partir dos resultados deste estudo foi possível concluir que, estatisticamente, o tipo de transferente não influencia na precisão da moldagem de implante unitário. No entanto, o TC, na S2, aonde existiu maior quantidade de material de moldagem, apresentou alteração de posição.<br>
254

Avaliação ao longo do tempo da osseointegração em 93 implantes em forma de platôs removidos de humanos

Gil, Luiz Fernando January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:04:50Z (GMT). No. of bitstreams: 1 327158.pdf: 831762 bytes, checksum: 7954cc7d9bd4484428bd1e4c54427f71 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar a osseointegração de implantes em forma de platôs removidos de humanos considerando o tempo de carga funcional e a variáveis relativas ao sistema de implante utilizado e a fatores ligados ao paciente. Foi realizada análise histomorfométrica (BIC/BAFO) em 93 implantes platôs funcionais removidos de humanos por razões protéticas, seguido da obtenção de dados relativos ao paciente e aos sistemas de implantes empregados, bem como o tempo de carga funcional. BIC, BAFO e o tempo de carga funcional foram correlacionados através do teste ANOVA a múltiplas variáveis independentes: tipo da superfície do implante, diâmetro, comprimento, maxilar (maxila/mandíbula) e região (anterior/posterior) de instalação; análise de regressão linear foi utilizada para avaliar a relação entre o tempo de carga funcional e BIC/BAFO. Os valores de BIC (R= .38, p < .001) e BAFO (R = .25, p < .02) aumentaram em função do tempo de carga funcional, entretanto, não puderam ser estatisticamente relacionados a nenhuma variável independente. Conclui-se que o aumento da osseointegração ao longo do tempo se dá independentemente de fatores relacionados ao paciente e aos sistemas de implantes.<br> / Abstract : The aim of this study was to assess the osseointegration in plateau root form implants as a function of functional loading time and implant/ patient related variables. Histomorphometric analysis (BIC/BAFO) was performed in 93 functional plateau root form implants retrieved due to prosthetic reasons, followed by patient?s chart analyses in order to obtain implant/patient related data as well as time of functional loading. ANOVA test was used to correlate BIC, BAFO and time of functional loading to multiple independent variables: implant surface type, diameter, length, arch (maxilla/mandible) and region (anterior/posterior) of placement; linear regression analysis was applied to assess the relationship between time of functional loading and BIC/BAFO. BIC (R= .38, p < .001) and BAFO (R = .25, p < .02) values increased in function of time of functional loading, however, BIC/BAFO were not statistically related to any of the independent variables. It may be concluded that osseointegration increases in function of time independently of implant system/patient related parameters.
255

Avaliação da microdureza e cor de cimentos resinosos inseridos em diferentes substância e PH

Santos Neto, Cássio dos January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:18:07Z (GMT). No. of bitstreams: 1 329721.pdf: 4532649 bytes, checksum: 18cb60d2e542b0328ffc57d72577675e (MD5) Previous issue date: 2014 / O objetivo deste estudo in vitro foi de avaliar a microdureza e a alteração da cor de quatro cimentos resinosos, imersos em seis diferentes substâncias e por diferentes períodos de tempo. Sessenta discos de cimentos resinosos, foram confeccionados (6mm x 2mm), para cada tipo de cimento (Rely - X Veneer (R), Rely-X U200 (U) , Multilink (M) e o Variolink Veneer (V)) e polidos com ponta de borracha de passo único (Optrapol, Ivoclar Vivadent) por 30 s, em seguida armazenados por 24 hrs em água destilada. A subdivisão foi realizado em 6 subgrupos (n=10), de acordo com a solução imersora, a uma temperatura de 37ºC: Grupo R-1(Rely-X Veneer), Grupo M-1 (Multilink), Grupo V-1 (Variolink Veneer) e o Grupo U-1(Rely-X U200), foram armazenadas em água destilada (controle (1)). Grupo R-2, M-2, V-2 e U-2 em coca (2). Grupo R-3, M-3, V-3 e U-3 em vinho (3), Grupo R-4, M-4, V-4 e U-4 em suco cítrico (4), Grupo R-5, M-5, V-5 e U-5 em whisky (5) e Grupo R-6, M-6, V-6 e U-6 embebida energética (6). Os espécimes foram mesurados imediatamente, 24 hrs, 7, 14 e 90 dias, por um microdurometro (HMV 2, Shimadzu - Japão) e a cor avaliada por um espectrofotômetro (Easyshade, Vita). Para a análise estatística dos dados, foi empregada a análise de variância multiplas, (ANOVA) e o teste de tukey ao nível de 95% de confiança. Os maiores valores de microdureza foram obtidos no baseline, seguido de 7, 14 e 90 dias. Apenas não houve diferença estatisticamente significante entre os tempos de 24 horas, 7 e 14 dias(p>0,05). Para os valores de 90 dias, ocorreu uma queda acentuada dos valores para a microdureza. Quando observados os espécimes submersos em água, nota-se alteração no armazenamento de 90 dias, mas sem diferença estatística. O líquido que promoveu o maior índice de alteração de cor foi o vinho nos grupos: R3, M3, V3 e U3. Esses dados prevaleceram em todos os cimentos testados, a partir do 7° dia de armazenamento. O /\E, não foi alterado para os grupos, que foram imersos em água. Os líquidos coca-cola, suco cítrico, whisky e energético, tiveram alteração significativa aos 90 dias de armazenamento. O grupo que apresentou a menor variação após os 14 dias foi o cimento resinoso Rely - X Veneer, porém sem diferença estatística. As substâncias nas quais os cimentos resinosos foram imersos, apresentaram influência na microdureza superficial e na cor para todos os cimentos testados, diminuindo a estabilidade de cor e a dureza em períodos mais longos.<br> / Abstracts: The aim of this in vitro study was to evaluate the microhardness and color change four resin cements immersed in six different substances and for different periods of time. Sixty discs of resin cements were cut (6mm x 2mm), for each type of cement (Rely X -Veneer (R), Rely-X U200 (U), Multilink (M) and Variolink Veneer (V)) and polished rubber tipped single step (Optrapol, Ivoclar Vivadent) for 30 s, then stored for 24 hrs in distilled water. The subdivision was carried out in six subgroups (n = 10) according to imersora solution at a temperature of 370C: R 1-group (Rely-X Veneer)-1 Group M (Multilink), GroupV-1 (Variolink Veneer) and the U-1 group (Rely-X U200) were stored in distilled water(control) (1). Group R-2, M-2, M-2 and U-2 cocaine (2). Group R-3, M-3, M-3 and H-3 'wine(3)-R 4 group, M-4, M-4 and U-4 as citric juice (4)-R 5 group, M-5, M-5 and H-5 whiskey (5)group R-6, F-6, V-6 and U-6 in the energy drink (6). The specimens were immediately mesurados, 24 hrs, 7, 14 and 90 days, by a microhardness (HMV 2, Shimadzu - Japan) and the color measured by a spectrophotometer (Easyshade, Vita). For statistical analysis, we used the multiple analysis of variance (ANOVA) and Tukey's test at 95% confidence.The highest microhardness values were obtained at baseline, followed by 7, 14 and 90 days. As there was no statistically significant difference between the times of 24 hours, 7 and 14 days (p> 0.05). For values of 90 days, there was a sharp decline in values for microhardness. When observing the specimens submerged in water, there is change in storage of 90 days, but no statistical difference. The liquid that promoted the highest rate of color change was the wine groups: R3, M3, V3 and U3. These data prevailed in all cements tested, from the 7th day of storage. The /\E, has not changed for the groups, which were immersed in water. Net cola, citrus juice, whiskey and energetic, had significantly after 90 days of storage change. The group that had the lowest variation after 14 days was the resin cement Rely X - Veneer, but without significant differences.
256

Indicadores de risco para a peri-implantite

Dalago, Haline Renata January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:08:41Z (GMT). No. of bitstreams: 1 327516.pdf: 2207766 bytes, checksum: 792f190101fbe0ce01d7efed233c87f5 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi identificar os indicadores de risco sistêmicos e locais associados com a peri-implantite e sua prevalência. Os critérios de inclusão para o estudo compreenderam: pacientes tratados com implantes de titânio Implacil De Bortoli (São Paulo, Brasil) na Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO), da Universidade de São Paulo (USP), no período de 1998 a 2012. Foram examinados 183 pacientes, reabilitados com 916 implantes em função por pelo menos 1 ano. As variáveis foram avaliadas segundo condição sistêmica do paciente, características do implante, coroa protética e parâmetros clínicos. A regressão logística não demonstrou associação de características do implante com a PI. Houve correlação estatística positiva para histórico de doença periodontal (DP), próteses cimentadas, presença de facetas de desgaste na coroa protética e próteses totais. A PI apresentou risco aumentado em 2.20 vezes para histórico de DP, 3.62 vezes para próteses cimentadas em relação às parafusadas, 2.43 vezes na presença de facetas de desgaste na coroa protética e 16.11 vezes para próteses totais em relação as parafusadas. Foram relacionados como indicadores de risco para a PI histórico de DP, próteses cimentadas, presença de facetas de desgaste na coroa protética e próteses totais. As características dos implantes não foram relacionadas com a PI.<br> / Abstract : The aim of this study was to identify systemic and local risk indicators associated with peri-implantitis (PI) and its prevalence. Inclusion criteria for the study were patients treated with osseointegrated implants (Implacil De Bortoli, Sao Paulo, Brazil) at FUNDECTO (University of Sao Paulo, USP), from 1998 to 2012. There were examined 183 patients, rehabilitated with 916 implants in function for 1 year at least. Variables were evaluated according to patient's systemic condition, implant's characteristics, prosthetic crown and clinical parameters. Logistic regression did not show any association between implant's characteristics with PI. Also, it was identified an increased risk of 2.20 times for historic of periodontal disease (PD), 3.62 times for cemented restorations compared to screw-retained, 2.43 times when displayed wear facets on the prosthetic crown and 16.11 times for total rehabilitations when compared to single rehabilitations. There were related as risk indicators for PI the historic of periodontal disease, cemented prostheses, presence of wear facets on the prosthetic crown and in total rehabilitations. Implants' characteristics were not related with PI.
257

Estimulação elétrica de superfícies de titânio em meio fisiológico simulado

Ely, Letícia Moro Bins January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-10-06T04:07:30Z (GMT). No. of bitstreams: 1 334727.pdf: 2116110 bytes, checksum: c9d5f442f334cd1811365c1804106429 (MD5) Previous issue date: 2015 / O tempo de integração óssea de implantes de titânio é reportado na literatura como sendo de 12 semanas em maxila e 6 semanas em mandíbula, aproximadamente. Novas técnicas e superfícies de implante têm sido desenvolvidas para acelerar a formação óssea e, consequentemente, diminuir o tempo de osseointegração. Um método alternativo aplicado em superfícies de implantes é baseado em estimulação elétrica. O objetivo deste estudo foi avaliar a influência da estimulação elétrica em superfície de titânio imersa em um meio fisiológico simulado. Discos de titânio comercialmente puro grau IV e liga de Ti6Al4V com dimensões de 8 por 15 mm foram polidos com lixas d?água de granulometrias decrescentes até 2500 e, posteriormente, polidas com feltro e alumina (1,0 µm; 0,5 µm e 0,3 µm). As amostras foram limpas com álcool 70% e com água destilada durante 10 minutos sob vibração ultra-sônica. Após esterilizadas, as amostras foram conectadas a um potenciostato, que induziu e monitorou corrente elétrica direta e constante sobre a superfície. As amostras de titânio foram inseridas em uma célula eletrolítica contendo meio eletrolítico e divididas em 2 grupos: Ti-CP e Ti6Al4V e cada grupo subdividido conforme a aplicação de corrente eléctrica e meio eletrolítico: C1 (0 µA sem meio); C2 (0 µA imersas em DMEM e soro fetal bovino); 5 µA e 10 µA (imersas em DMEM e soro fetal bovino). Após estimulação elétrica, avaliou-se a adsorção de proteínas por testes quantitativos de Lowry e FTIR. As superfícies de titânio foram caracterizadas por testes eletroquímicos de potencial de circuito aberto e impedância e por análise topográfica a partir de microscopia de força atômica (AFM) e microscopia eletrônica de varredura (MEV). A partir das análises por FTIR, observou-se a presença de bandas de energia características de amida em todas as amostras submersas em solução fisiológica indicando a presença de proteínas. Pelo método de Lowry a maior quantidade de proteína total adsorvida ocorreu nos subgrupos C2 (p < 0,05). Quanto às alterações morfológicas, o teste de perfilometria indicou maiores valores de Ra para as amostras de titânio puro submetidas a 10 µA (p < 0,05). As superfícies de Ti6Al4V apresentaram os maiores valores de Ra para 5 µA, mas sem diferença estatística com o subgrupo 10 µA (p > 0,05). As imagens do MEV não revelaram diferenças entre os grupos. Quando submetidas aos testes eletroquímicos, as amostras testes (5 µA e 10 µA) apresentaram maior resistência à corrosão. Foram encontradas alterações eletroquímicas e topográficas em superfície de Ti-CP e Ti6Al4V após estimulação elétrica em meio fisiológico simulado.<br> / Abstract : The required time for a titanium implant to become functional is reported in the literature as 12 weeks in maxilla and 6 weeks in mandible, approximately. New techniques and implant surfaces have been developed for accelerating bone formation and consequently reduce osseointegration time. An alternative method applied on implants surfaces is based on electrical stimulation. The aim of this study was to evaluate the electrical stimulation influence on titanium surface immersed in a physiological simulated environment. Commercially pure titanium grade IV and Ti6Al4V alloy with dimensions of 8 x 15 mm were wet ground on SiC abrasive papers down to 2500 Mesh and polished with alumina (1.0; 0.5 and 0.3 µm). After grinding, the samples were cleaned with 70% ethanol and distilled water for 10 minutes under ultrasonic bath. After sterilized, the samples were connected to a potentiostat, which induced and monitored direct and constant electric current on the surface. The titanium samples were placed in an electrolytic cell containing electrolyte medium and divided into 2 groups: Ti-CP and Ti6Al4V, further divided according to electric current application and electrolyte means: C1 (0 µA without medium); C2 (0 µA immersed in DMEM and FBS); 5 µA to 10 µA (immersed in DMEM and FBS). After electrical stimulation, proteins adsorption was quantitative evaluated by Lowry and FTIR tests. Titanium surfaces were characterized by open circuit potential, impedance and topographic analysis from atomic force microscopy (AFM) and scanning electron microscopy (SEM). FTIR analysis, showed the presence of amide energy bands characteristic in all samples immersed in DMEM + FBS indicating the presence of proteins. By the Lowry method the greatest amount of total protein adsorbed was C2 subgroups (p <0.05). Regarding morphological change, the profilometry testing showed higher Ra values for pure titanium samples submitted to 10 µA (p <0.05). Ti6Al4V surfaces had the highest Ra values for 5 µA, but no statistical difference with subgroup 10 µA (p> 0.05). SEM images revealed no differences between the groups. When submitted to electrochemical tests, test samples (5 µA and 10 µA) showed greater corrosion resistance. Was found electrochemical and topographical changes in Ti-CP and Ti6Al4V surfaces after electrical stimulation in physiological simulated environment.
258

A influência da geometria do implante na perda óssea peri-implantar: um estudo de corte transversal em humanos

Pereira, Maurício Assunção January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-10-20T03:09:26Z (GMT). No. of bitstreams: 1 334974.pdf: 4222482 bytes, checksum: b816c820b76f13f0f6f109d73ee460ca (MD5) Previous issue date: 2015 / Objetivo: O objetivo deste estudo foi verificar a influência da geometria do implante na perda óssea peri-implantar. Materiais e métodos: Pacientes tratados com implantes de titânio Implacil De Bortoli (São Paulo, Brasil) na Fundação para o Desenvolvimento Científico e Tecnológico da Odontologia (FUNDECTO), da Universidade de São Paulo (USP), no período de 1998 a 2012 foram chamados para consulta de manutenção. Entre Abril a Novembro de 2013, foram examinados 183 pacientes reabilitados com 916 implantes em função por pelo menos um ano. A variável perda óssea marginal foi avaliada segundo o fator: tipo de implante (forma cilíndrica ou cônica e conexão hexagonal interna ou externa). Resultados: O teste t para médias de amostras independentes com variâncias desconhecidas mostrou perda óssea significante maior para os implantes cilíndricos quando se considera como ponto de referência coronal para aferir a perda óssea o topo do implante. Mas, quando se utiliza a base do colar liso como ponto de referência coronal para aferição, a situação se inverte e os implantes de forma cônica apresentam perda óssea significativamente maior. Conclusões: Todos os grupos de implantes estudados apresentaram baixos valores de perda óssea peri-implantar. A geometria do implante e o comprimento do colar liso têm significativa influência na perda óssea peri-implantar. Implantes cônicos, com micro espiras cervicais e menor comprimento de colar liso, mostraram menor perda óssea marginal.<br> / Abstract : Objective: The aim of this study was to investigate the influence of implant geometry in peri-implant bone loss. Materials and methods: From April to November 2013, there were examined 183 patients treated with osseointegrated implants (Implacil De Bortoli, Sao Paulo, Brazil) performed at FUNDECTO (University of Sao Paulo - USP) from 1998 to 2012, rehabilitated with 916 implants in function for 1 year at least. The variable marginal bone loss was assessed according to the factor type of implant (cylindrical or conical shape and internal or external hexagonal connection). Results: The t test for means of independent samples with unknown variance showed significant greater bone loss for cylindrical implants when considering the top of the implant as coronal reference point to measure bone loss the. But, when the base of smooth neck was used as a coronal reference point for measuring the conical implants have significantly higher bone loss. Conclusions: All studied implant groups had low peri-implant bone loss values. The implant geometry and the smooth neck length significantly influence peri-implant bone loss. Tapered implants with shorter smooth neck length and cervical micro threads had lower marginal bone loss.
259

Efeito de sistema adesivo e dentifrício fluoretados no desenvolvimento de cárie ao redor de restaurações com e sem fenda marginal em esmalte e dentina: estudo in situ / In situ effect of fluoride from adhesive system and dentifrice on caries formation around restorations with gap in enamel and dentine

Bezerra, Daniela da Silva January 2010 (has links)
BEZERRA, Daniela da Silva. Efeito de sistema adesivo e de dentifrício fluoretados no desenvolvimento de cárie ao redor de restaurações com e sem fenda marginal em esmalte e dentina : estudo in situ. 2010. 56 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2010. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-06T13:11:55Z No. of bitstreams: 1 2010_dis_dsbezerra.pdf: 994675 bytes, checksum: 7baa7ae43392863a9549272d083a84cc (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T12:14:40Z (GMT) No. of bitstreams: 1 2010_dis_dsbezerra.pdf: 994675 bytes, checksum: 7baa7ae43392863a9549272d083a84cc (MD5) / Made available in DSpace on 2012-02-01T12:14:40Z (GMT). No. of bitstreams: 1 2010_dis_dsbezerra.pdf: 994675 bytes, checksum: 7baa7ae43392863a9549272d083a84cc (MD5) Previous issue date: 2010 / Secondary caries may be developed between tooth and restoration when marginal gaps are present, however this process could be inhibited by fluoride presence. This research had as the main objective to evaluate, in situ, through a randomized, split-mouth and double-blind, cross-over design, the influence of fluoride from self-etching adhesive systems or dentifrice on the secondary caries development on enamel and root dentine around composite resin restorations with or without marginal gaps. During two phases, of 14 days each, 16 volunteers wore intraoral palatal devices containing 4 human dental slabs composed by a portion of enamel and dentine, restored with Z-250 composite resin. The slabs were randomly divided among 8 experimental groups for each substrate (enamel and dentine) restored with one of the following adhesive: All Bond SETM (no fluoride - NFA) and One Up® Bond F Plus (fluoride - FA) with (G+) or without (G-) the presence of marginal gaps and the use of fluoride dentifrice (FD) or placebo (PD). The restoration procedures were made following the manufacturers instructions and the gap was induced with the use of metallic strips. Each volunteer was instructed to drop on the slabs a 20% sucrose solution 10x/day and use the standardized dentifrice 3x/day. By the end of each clinical phase, the dental slabs were removed and the biofilm was collected for total microorganisms, mutans streptococci and lactobacilli counting, as well as for analysis of fluoride quantity present. The mineral loss was analyzed by microhardness test in a longitudinal cut on enamel and dentine. The lesion depth and presence of the wall lesion were determined by polarized light microscopy. The results were analyzed by ANOVA, following a factorial delineation of 2x2x2. The fluoride from the adhesive did not provide any protection against secondary caries development for enamel and dentine and for none of the studied response variables (p > 0.05). The fluoride from the dentifrice showed a little protection for demineralization in dentin (p<0.05). There was more wall lesion presence, either on enamel or on dentine (p < 0.05), on restorations with gap irrespective of fluoride presence. However, on gap restorations, a bigger depth of lesion was observed only on dentine (p < 0.05). These results suggest that the fluoride from the adhesive was not able to inhibit demineralization around restorations, even in the fluoride dentifrice presence. Nevertheless, the presence of a visible gap affects the secondary caries development, mainly on root dentine, increasing the progression of caries disease. / Cáries secundárias podem desenvolver-se na interface dente-restauração diante da presença de fendas marginais, mas este processo poderia ser inibido pela presença de flúor. Esta pesquisa teve como objetivo avaliar, in situ, através de um delineamento cruzado, aleatorizado, boca dividida e duplo-cego, a influência do flúor proveniente de sistema adesivo autocondicionante ou dentifrício no desenvolvimento de cárie secundária em esmalte e dentina radicular ao redor de restaurações de resina composta com ou sem fenda marginal. Durante duas fases de 14 dias, 16 voluntários utilizaram dispositivos intra-orais palatinos contendo 4 blocos de dente humano compostos por uma porção de esmalte e dentina e restaurados com resina composta FiltekTM Z-250. Os blocos foram aleatoriamente divididos em 8 grupos experimentais para cada substrato (esmalte e dentina) restaurado com um dos seguintes adesivos: All Bond SETM (não fluoretado - ANF) e One Up® Bond F Plus (fluoretado - AF), com a presença de fendas marginais (G+) ou não (G-), e com o uso de dentifrício fluoretado (DF) ou placebo (DP). Os procedimentos restauradores foram realizados seguindo as instruções dos fabricantes e a fenda foi criada com a utilização de matrizes metálicas. Cada voluntário foi instruído a gotejar sobre os blocos uma solução de sacarose a 20%, 10 vezes ao dia e a usar o dentifrício padronizado 3 vezes ao dia. Ao final de cada fase clínica, os blocos dentais foram removidos e o biofilme foi coletado para a contagem de estreptococos do grupo mutans, lactobacilos e microrganismos totais, assim como para a análise da quantidade de flúor presente. A perda mineral foi analisada pelo teste de microdureza em corte longitudinal no esmalte e na dentina. A profundidade da lesão e a presença de lesão da parede foram determinadas por microscopia de luz polarizada. Os resultados foram analisados por análise de variância (ANOVA) seguindo um delineamento fatorial 2x2x2. O flúor do adesivo não ofereceu proteção contra o desenvolvimento de cárie secundária em esmalte e dentina para nenhuma das variáveis de resposta estudadas (p > 0,05). O flúor do dentifrício mostrou leve proteção contra a desmineralização em dentina (p < 0,05). Houve uma maior presença de lesão de parede, tanto em esmalte quanto em dentina (p< 0,05), em restaurações com fenda independente da presença de flúor. No entanto, em restaurações com fenda, uma maior profundidade de lesão foi observada em dentina (p <0,05). Estes resultados sugerem que o flúor do adesivo não foi capaz de inibir a desmineralização ao redor de restaurações mesmo com a presença de flúor no dentifrício. No entanto, a presença de fenda visível afeta o desenvolvimento de cárie secundária, principalmente na dentina radicular, aumentando a progressão da lesão cariosa.
260

A prevalência e o perfil epidemiológico do traumatismo dentário em escolares da rede pública municipal de Fortaleza - Ceará

Dias, Rosana Sales January 2008 (has links)
DIAS, Rosane Sales. A prevalência e o perfil epidemiológico do traumatismo dentário em escolares da rede pública municipal de Fortaleza - Ceará. 2008. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T11:39:41Z No. of bitstreams: 1 2008_dis_rsdias.pdf: 412177 bytes, checksum: 2c726dfb68ab5595edf2e78a4c8c5469 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T15:58:05Z (GMT) No. of bitstreams: 1 2008_dis_rsdias.pdf: 412177 bytes, checksum: 2c726dfb68ab5595edf2e78a4c8c5469 (MD5) / Made available in DSpace on 2012-02-02T15:58:05Z (GMT). No. of bitstreams: 1 2008_dis_rsdias.pdf: 412177 bytes, checksum: 2c726dfb68ab5595edf2e78a4c8c5469 (MD5) Previous issue date: 2008 / The purpose of this study was to determine the frequency and epidemiological profile of dental trauma among 6-12-year-old schoolchildren regularly attending the municipal public schools of Fortaleza, CE, Brazil, in 2007. Five hundred schoolchildren proportionally divided among the six regional executive educational bureaus were examined and data referring to age, gender, traumatized tooth/teeth, type of trauma, tooth loss due to trauma, presence of fistula, discoloration, restoration related to the traumatized tooth/teeth and predisposing factors were recorded on clinical forms. The data were grouped and each category was analyzed statistically by the chi-square test. The results revealed that among the 500 examined children, 130 (25.7%) had suffered dental trauma to either primary teeth (14 children - 2.9%) or permanent teeth (116 children - 22.8%). The age of 10 years had the most frequency of dental trauma (20.9%). The female gender was more prevalent (61.4%). The maxillary left central incisor (8.4%) and the maxillary right central incisor (6.8%) were the most frequently traumatized teeth. Fracture was the most prevalent type of dental trauma, corresponding to 23.7% of the cases. Tooth loss due to traumatic injury occurred in only 0.4% of the cases. Discoloration was absent in 97% of the patients. Enamel fracture was the most prevalent of all types of fractures (17.7%) followed by enamel/dentin fracture (4.4%). The data showed that 99.8% of the schoolchildren who presented fractured teeth did not receive adequate dental treatment. Composite traumas and fistulae occurred in only 0.4% and 0.1% of the patients, respectively. Regarding the predisposing factors, alterations in the overjet was observed in 33.7% of the children and inadequate lip coverage was present in 17.3%. The findings of the present study allowed concluding that, in general, family, educational authorities and caregivers should have sufficient knowledge to provide a safe environment and adequate care at the moment of a dental trauma in such a way that its sequelae can be prevented or minimized. / O objetivo deste trabalho foi determinar a freqüência e o perfil epidemiológico do traumatismo dentário em escolares, na faixa etária entre 6 e 12 anos, matriculados na rede pública municipal de Fortaleza-Ceará-Brasil, no ano de 2007. Foram examinados 500 escolares divididos proporcionalmente entre as seis secretarias executivas regionais e os dados como idade, sexo, elemento dentário acometido pelo trauma, tipo de trauma, perda em razão de trauma, presença de fístula, descoloração, restauração relacionada ao dente traumatizado e fatores predisponentes foram anotados em uma ficha clínica. Os dados foram agrupados e, para cada categoria avaliada, empregou-se o teste estatístico do qui-quadrado. Os resultados mostraram que, dos 500 escolares examinados, 130 apresentaram dentes traumatizados (25,7%), sendo 14 em dentes decíduos (2,9%) e 116 em dentes permanentes (22,8%). A idade mais acometida por traumatismo dentário foi dez anos (20,9%). O gênero feminino foi o mais prevalente (61,4%). O incisivo central superior esquerdo (8,4%) e o incisivo central superior direito (6,8%) foram os dentes mais envolvidos em traumatismos dentários. A fratura foi o tipo de trauma mais prevalente, com 23,7% dos casos. A perda decorrente de trauma representou no presente estudo apenas 0,4% dos casos. A descoloração apresentou-se ausente em 97% dos pacientes examinados. A fratura mais prevalente foi a fratura de esmalte (17,7%), seguida pela fratura de esmalte e dentina (4,4%). Neste estudo, 99,8% dos escolares que apresentaram dentes fraturados por trauma não receberam tratamento adequado. Os traumas combinados só ocorreram em 0,4% dos casos, como também a presença de fístula (0,1%). Quanto aos fatores predisponentes, observou-se alteração de sobressaliência em 33,7% dos pacientes examinados, e selamento labial inadequado em 17,3% dos casos. Os resultados permitiram concluir que familiares, autoridades educacionais e cuidadores de crianças em geral deveriam ser portadores de conhecimentos suficientes para desenvolver um ambiente seguro e cuidados adequados no momento do traumatismo dentário e assim prevenir e minimizar as seqüelas de traumatismo dentário.

Page generated in 0.0388 seconds