• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Resistência e tipo de falha de união de materiais retrobturadores /

Vivan, Rodrigo Ricci. January 2012 (has links)
Orientador: Mário Tanomaru Filho / Banca: Fábio Luis Camargo Villela Berbert / Banca: José Mauricio dos Santos Nunes Reis / Banca: Marco Antonio Hungaro Duarte / Banca: Edson Alfredo / Resumo: O presente estudo avaliou a resistência e tipo de falha de união de materiais retrobturadores à parede do canal radicular por meio do teste push-out. Capítulo 1 - Foi realizada comparação da resistência de união por compressão (push-out) e tipo de falha dos materiais retrobturadores MTA Angelus, MTA Sealer, Sealer 26 e OZE. Foram utilizadas 40 fatias de 2 mm de espessura de dentes unirradiculados humanos. Após preparo inicial do canal radicular com broca cilíndrica com 1,5 mm de diâmetro, o preparo retrógrado foi confeccionado com ponta de ultrassom CVD T0F-2. Os corpos-de-prova foram divididos aleatoriamente em 4 grupos (n=10) de acordo com o material retrobturador: Grupo 1: MTA Angelus; grupo 2: MTA Sealer; grupo 3: Sealer 26; grupo 4: OZE. Para o teste, cada espécime foi posicionado na máquina de ensaios mecânicos (EMIC DL 2000) com velocidade de 1mm/min e célula de carga de 5kN, para a realização do teste de push-out. Também foi avaliada a presença dos cimentos nas paredes radiculares por meio do microscópio confocal de varredura a laser, e análise do tipo de falha em estereomicroscópio. Os dados foram submetidos ao teste estatístico de ANOVA e Tukey, com nível de significância de 5%. Os resultados de push-out mostraram maior adesão para MTA Angelus (19,18 MPa) e MTA Sealer (19,13 MPa), seguidos do Sealer 26 (15,91 MPa). O cimento OZE (9,50 MPa) apresentou menor adesão que os demais cimentos estudados, com diferença estatisticamente significante (p<0,05). Em relação a presença de cimento, o cimento OZE (89,77%) e o MTA Sealer (83,06%) apresentaram os maiores valores, seguidos pelo Sealer 26 (59,33%), sem diferença significante entre os materiais (p>0.05). Em relação ao tipo de falha, predominou a falha adesiva, com exceção do grupo 4 (OZE), onde predominou a falha mista. Conclui-se que os materiais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of study was to evaluate the bond strength and failure type to root-end filling materials wall by means of push-out test. Chapter 1 - the aim of this study was to evaluate the bond strength and failure type of root-end filling materials MTA Angelus, MTA Sealer, Sealer 26 and OZE. 40 slices were used 2 mm thick of human teeth. After initial root canal preparation with cylindrical drill with 1.5 mm in diameter, the root-end preparation was made with ultrasound tip CVD T0F-2. The specimens were randomly divided into 4 groups (n=10) according to the root-end filling materials: Group 1: MTA Angelus; Group 2: MTA Sealer; Group 3: Sealer 26; Group 4: OZE. For the test, each specimen was positioned in the mechanical testing machine (EMIC DL 2000) with 1mm/min speed and load cell of 5KN to the completion of the push-out test. It was also evaluated the presence of cement through the confocal scanning laser microscope and analysis of failure type in stereomicroscope. The data were submitted to ANOVA and Tukey test statistic with significance level of 5%. The results of push-out showed greater bond strength to MTA Angelus (19,18 MPa) and MTA Sealer (19,13 Mpa), followed the Sealer 26 (15,91 Mpa). OZE (9.50 Mpa) showed lower accession than other materials, with statistically significant (p 0.05). In relation to presence of cement, the OZE (89.77%) and the MTA Sealer (83.06%) showed the greatest values, followed by Sealer 26 (59.33%), no significant difference between the materials (p> 0.05). In relation to the type of failure, predominated the adhesive failed, with the exception of Group 4 (OZE), which predominated the coesive failure. It is concluded that the MTA Angelus, MTA Sealer and Sealer 26 exhibit bond strength as root-end filling materials. Chapter 2 - the aim of this study was to evaluate... (Complete abstract click electronic access below) / Doutor
302

Avaliação da formação de fendas marginais e da microinfiltração após envelhecimento artificial, empregando adesivos autocondicionantes fotopolimerizáveis ou duais associados à resinas compostas de diferentes viscosidades /

Cortez Gutierrez, Natália. January 2012 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Alessandra Bühler Borges / Banca: Ricardo Amore / Resumo: O objetivo deste estudo foi avaliar a influência do tipo de resina composta com relação à viscosidade, do tipo de adesivo autocondicionante e seu modo de presa e do envelhecimento artificial, na formação de fendas marginais e microinfiltração de restaurações de resina composta. Cavidades padronizadas com 4 mm de diâmetro e 2,5 mm de profundidade foram preparadas em 240 incisivos bovinos. Eles foram divididos em 2 grupos de acordo com a viscosidade da resina composta: GC - Grandio SO (Voco - viscosidade convencional) e GF - Grandio SO Heavy Flow (Voco - baixa viscosidade), ambas com alto conteúdo de carga. Cada grupo foi dividido em seis subgrupos, de acordo com os sistemas adesivos utilizados: FM - Futura Bond M (Voco), FDCF - Futura Bond DC (Voco) - fotopolimerizado, FDCQ - Futura Bond DC (Voco) - apenas polimerização química, CS - Clearfil S3 Bond (Kuraray), CDCF - Cleafil DC (Kuraray) - fotopolimerizado e CDCQ - Clearfil DC (Kuraray) - apenas polimerização química. Metade dos espécimes foi submetida à ciclagem mecânica (300.000 ciclos) e térmica (1.000 ciclos), sendo divididos então em C - ciclados e NC - não ciclados. A maior fenda marginal presente nas margens de cada restauração foi medida em microscópio óptico, em micrometros. Para a avaliação da microinfiltração, os espécimes foram submersos em solução de nitrato de prata amoniacal 50% por 24h, lavados, colocados em revelador radiográfico por 8h sob luz fluorescente e seccionados. As interfaces foram fotografadas e a microinfiltração mensurada em milímetros. Os dados foram submetidos à ANOVA três fatores. Para fenda marginal foi encontrada diferença significativa para todos os fatores (p=0,00). Os resultados de Tukey para resina foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of composite viscosity, adhesive systems type of cure and artificial aging on marginal gap formation and microleakage of composite resin restorations. Cavities with 4mm in diameter and 2,5mm deep were prepared in 240 bovine incisors. Teeth were divided in two groups according to the viscosity of composite resin: GC - Grandio SO (Voco - conventional viscosity), GF - Grandio SO Heavy Flow (Voco - low viscosity), both with higher filler content. Each group was divided into 6 subgroups, according to the bonding systems: FM - Futura Bond M (Voco), FDCF - Futura Bond DC (Voco) - light cured, FDCQ - Futura Bond DC (Voco) - chemical cured only, CS - Clearfil S3 Bond (Kuraray), CDCF - Cleafil DC (Kuraray) - light cured and CDCQ - Clearfil DC (Kuraray) - chemical cured only. Half of the specimens were subjected to mechanical (300.000) and thermal cycling (1.000). So specimens were then divided into WITH and WITHOUT thermo-mechanical cycling. The biggest marginal gap for each restoration was measured in an optical microscope in microns. For microleakage evaluation, specimens were submersed in 50% ammoniacal silver nitrate for 24h, washed for 20min and placed in radiographic developer for 8h under fluorescent light. Teeth were sectioned and the interface with the deepest microleakage in millimeters was measured. Data were analyzed with three-way ANOVA and Tukey's test. For marginal gaps significant differences were shown for all factors (p=0.000). Tukey's test results for resin were GC: 28.10a e GF: 40.60b; for adhesive CDCQ: 28.67a, CDCF: 32.25b, CS: 34.12bc, FDCF: 36.10cd, FM: 36.50cd e FDCQ: 38.46d; and for artificial aging WITHOUT: 29.05a and WITH: 39.65b. For microleakage, there were also differences for all factors (p=0.000). The results of Tukey's test... (Complete abstract click electronic access below) / Mestre
303

Estudo in vivo da fidelidade de reprodução com moldeiras de dupla arcada

Lima, Luciana Martinelli Santayana de January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:11Z (GMT). No. of bitstreams: 2 000386496-0.pdf: 391577 bytes, checksum: 23af4cf9ce3630d39442fc9f6ba06efb (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated, in vivo, the accuracy of mettalic (Smart) and plastic (Triple Tray) dual-arch trays employed with vinyl polyxiloxane (Flexitime), in the putty/wash consistency, as well as polyether (Impregum Soft), in the regular consistency. In one patient, a transferent was parafusado on implant in the mandibular right first molar. The tranferent served as a master model. Ten impression with each tray and impression material were made. The impressions were cast in type IV die stone after 1 hour. The width and height of the master model and gypsum models were measured in a perfil projector (Nikon). The results were submitted to Student’s t-test for one sample (α=0. 05). For the width distance, the plastic dual-arch trays with vunyl polyxiloxane (4. 513 mm) and with polyether (4. 531 mm), and metallic dual-arch tray with polyether (4. 500 mm) were statistically greater than the master model (4. 489 mm). The metallic dual-arch tray with vinyl polyxiloxane (4,504 mm) did not differed statistically from the master model. For the height distance, only the metallic dual-arch tray with polyether (2. 253 mm) differed statistically from the master model (2. 310 mm). The dual-arch metallic tray with vinyl polyxiloxane reproduced models with less distortion. / Este estudo avaliou, in vivo, a fidelidade de reprodução das moldeiras de dupla arcada metálica (Smart) e plástica (Triple Tray) com os materiais de impressão silicone por adição (Flexitime), nas consistências massa e leve, e o poliéter (Impregum Soft) na consistência regular. Em um paciente com implante na região do dente 46 foi parafusado um transferente modificado, servindo este de padrão. Foram realizadas dez impressões com cada associação moldeira / material. Os moldes foram vazados com gesso tipo IV após 1 hora. As medidas de largura e altura foram realizadas no padrão e nos modelos, em um projetor de perfil (Nikon). Os resultados foram analisados pelo teste t-student para uma amostra (α=0,05). Para a medida da largura, as moldeiras plásticas com silicone por adição (4,513 mm) e com poliéter (4,531 mm), e a moldeira metálica com poliéter (4,500 mm) foram estatisticamente superiores ao padrão (4,489 mm), sendo que a moldeira metálica com silicone por adição (4,504 mm) não diferiu estatisticamente do padrão. Para a altura, somente a moldeira metálica com poliéter (2,253 mm) diferiu estatisticamente do modelo mestre (2,310 mm). A moldeira de dupla arcada metálica associada ao silicone por adição foi a que reproduziu modelos com menor distorção.
304

Torque de remoção de implantes lisos e texturizados com e sem estabilidade primária associados ou não ao plasma rico em plaquetas

Suzuki, Roberto Makoto January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:00Z (GMT). No. of bitstreams: 2 000399345-0.pdf: 1607663 bytes, checksum: 3e900d3262bbff08d819d4414119f515 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Rough implant surfaces and platelet-rich plasma are thought to enhance titanium osseointegration. Torque removal forces have been used as a biomechanical measurement of endosseous integration or bone anchorage, in which higher forces required to remove implants from the bone may be interpreted as an increase in the strength of bony integration. The purpose of this study was to evaluate the effect of primary stability of machined implants (MI) and sandblasted/acid-etched (SBAE) titanium implants associated with platelet-rich plasma (PRP) on the resistance to reverse torque removal. These factors were evaluated in six groups: 1- MI with primary stability and without PRP; 2- MI without primary stability and without PRP; 3- MI without primary stability and with PRP; 4- SBAE with primary stability and without PRP; 5- SBAE without primary stability and without PRP; 6- SBAE without primary stability and with PRP. Forty two implants were inserted in seven adult New Zealand white rabbits (Oryctolagos Cuniculus L. ). Three implants were inserted in each tibiae according to the above described groups. After a healing period of 9 weeks the animals were sacrificed and the implants were removed by reverse torque rotation with a digital torque-measuring device. Mean torque values were: 1- 53,01 Ncm (±9,68); 2- 45,29 Ncm (±16, 90); 3- 43,43 Ncm (±16,70); 4- 56,60 Ncm (±16,00); 5- 46,89 Ncm (±15,60) and 6- 48,49 Ncm (±17,06), respectively. No significant difference was detected among the groups (p>0,05). In this study it was not possible to demonstrated a statistically significant improved stability of implants subjected to PRP and texturized implants as compared to other groups. / O objetivo desse estudo foi avaliar o torque de remoção de implantes lisos e texturizados sem estabilidade primária associados a plasma rico em plaquetas. Foi utilizado um total de sete coelhos fêmeas, brancas da raça Nova Zelândia Branco (Oryctolagos cuniculus l. ). Em cada coelho foram instalados 6 implantes, 3 para cada tíbia, de acordo com os seguintes grupos experimentais: 1- implante liso com estabilidade primária e sem PRP (plasma rico em plaquetas); 2- implante liso sem estabilidade primária e sem PRP; 3- implante liso sem estabilidade primária e com PRP; 4- implante texturizado com estabilidade primária e sem PRP; 5- implante texturizado sem estabilidade primária e sem PRP; 6- implante texturizado sem estabilidade primária e com PRP. Os protocolos cirúrgicos foram aplicados de acordo com cada grupo experimental e após um período de 9 semanas, os animais foram mortos. Logo após a morte dos animais, a mensuração do torque de remoção foi realizada. As médias dos grupos foram: grupo 1, 53,01 Ncm (±9,68); grupo 2, 45,29 Ncm (±16, 90); grupo 3, 43,43 Ncm (±16,70); grupo 4, 56,60 Ncm (±16,00); grupo 5, 46,89 Ncm (±15,60) e grupo 6, 48,49 Ncm (±17,06). Os dados foram analisados através da Análise de Variância Múltipla, utilizando o delineamento em blocos casualizados que demonstrou não haver diferença estatística entre os grupos ao nível de 5% nas condições experimentais estabelecidas. As distintas condições experimentais não foram capazes de promover diferença no torque de remoção.
305

Avaliação da resistência de união e da adaptação interna entre cavidade dentinária e adesivos aplicados em uma e duas camadas

Soares, Clarissa Grassi January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000398957-0.pdf: 156371 bytes, checksum: ef32419ab3a2f6ff5a17e3f6a5e25149 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This research evaluated the influence of the adhesive layers of three adhesive systems on: 1) the microtensile bond strength (μTBS) to dentine and the fracture pattern; 2) the dentine/composite resin interfacial adaptation (DIA). Two cavities measuring 4 x 4 x 2 mm in samples for DIA, and 3,5 x 3,5 x 1,5 mm in samples for μTBS (factor C=3), 2 mm distant among themselves, were made at the vestibular surfaces of 30 incisive bovine. Scotchbond Multi-Purpose (MP), Single Bond 2 (SB) (3M/ESPE) and Clearfil SE Bond (CF) (Kuraray) were applied in one layer (MP-I, SB-I and CF-I) and in two layers (MP-II, SB-II and CF-II), being light-cured separately for 20 s. The composite resin Z250 (color A3) was inserted in four increments. Ten teeth for each adhesive system were used, being five for each test. After 48 h, resin/dentin sticks were made (n=15/group), with 0. 53 mm2 of adhesive area mean for μTBS test, and slices containing the two restorations with thickness among 0,15 - 0,20 mm (n=15/group) for DIA analysis. The sticks were submitted to the μTBS test using the universal testing machine EMIC DL-2000 and, after the test, the extremities were analyzed by SEM to classify the fracture pattern. The slices were analyzed in a Leica DMR optical microscope at x10, using polarized light and differential interference contrast microscope images. The restorations images were captured by a Nikon Coolpix 990 digital camera and the types and amounts of flaws (gap, crack, rupture) were classified. The mean values of μTBS were submitted to ANOVA Factorial and Turkey’s test (á=0. 05). The factors adhesive (p=0,001) and layers (p=0,025) presented significant difference, but the interaction among them did not have significant difference (p=0. 189). The mean values of μTBS were the following: MP-II: 56. 92; MP-I: 52:23; CF-II: 47:71; CF-I: 42. 25; SB-I: 35. 12; SB-II: 34. 69. The predominant fracture pattern was mixed failure. For DIA analysis, the Kruskal-Wallis test (á=0. 05) showed statistics differences for cracks and ruptures between the adhesives systems. SB-I and II had the highest values of cracks, and MP-I, the lowest value. SB-II showed significantly greater values for rupture. The application of two layers did not favor the results of μTBS and of DIA. / Esta pesquisa avaliou a influência do número de camadas de adesivo de três sistemas adesivos sobre: 1) a resistência de união à microtração (μT) à dentina e o padrão de fratura; 2) a adaptação interna (AInt) entre estrutura dentinária e restauração de resina composta. Nas faces vestibulares de 30 incisivos bovinos foram confeccionadas duas cavidades, uma incisal e uma cervical, distantes 2 mm entre si, com 4 x 4 x 2 mm nas amostras para a AInt e 3,5 x 3,5 x 1,5 mm para a μT (fator C=3). Os adesivos Scotchbond Multi- Uso (MP), Single Bond 2 (SB) (3M/ESPE) e Clearfil SE Bond (CF) (Kuraray) foram aplicados em uma camada (MP-I, SB-I e CF-I) e em duas camadas (MP-II, SB-II e CF-II), sendo fotopolimerizadas separadamente por 20 s. A resina composta Z250 (3M/ESPE), na cor A3, foi inserida em incrementos. Para cada sistema adesivo foram utilizados dez dentes, sendo cinco para cada teste. Após 48 h foram obtidos palitos de resina/dentina (n=15/grupo), com área adesiva média de 0,53 mm2, para a μT, e fatias com espessura entre 0,15 - 0,20 mm contendo as duas restaurações (n=15/grupo) para a AInt. Os palitos foram submetidos ao ensaio de μT na máquina EMIC DL2000 e, após o teste, as extremidades foram analisadas em MEV para classificação do padrão de fratura. As fatias foram analisadas com 10 x de aumento em microscópio óptico Leica DMR com sistema de luz polarizada e contraste interferencial. As imagens das restaurações foram capturadas por uma câmera digital Nikon Coolpix 990, sendo analisados os tipos e quantidades de falhas (fenda, trinca, ruptura). Os valores médios de μT foram submetidos à ANOVA Fatorial e teste de Tukey (á=0,05).Os fatores adesivos (p=0,001) e camadas (p=0,025) apresentaram diferença significativa, mas a interação entre eles não teve diferença significativa (p=0,189). Os valores médios de μT foram os seguintes: MP-II: 56,92; MP-I: 52,23; CF-II: 47,77; CFI: 42,25; SB-I: 35,12; SB-II: 34,69. A fratura do tipo mista foi predominante. Em relação à AInt, houve diferença estatística entre os adesivos para trincas e rupturas de acordo com o teste de Kruskal-Wallis (á=0,05). O SB-I e II teve os maiores valores de trincas e, o MP-I, os menores. Para rupturas, SB-II apresentou valores estatisticamente superiores. A aplicação de duas camadas não favoreceu os resultados de μT e de AInt.
306

Degradação das forças geradas por cadeias elásticas

Arteche, Álvaro Antônio de Freitas January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:11Z (GMT). No. of bitstreams: 2 000425717-0.pdf: 985525 bytes, checksum: 1409745d664f74c4d1969f3e154f3926 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The elastic chains are used extensively in orthodontics treatments because they are comfortable to the patient, easy to use, hygienic and low cost. However, when stretched in the oral environment, due to the absorption of water and temperature changes, the elastic chains undergo a permanent deformation and degradation of the initial force. The technology employed by the elastic chain manufacturer and the material used defines how fast and how much the force degradation of this material occurs when in oral environment. To evaluate the force degradation in elastic chain from six different commercial brands, the elastic elements were stretched upon jigs fixed to the brackets of 20 patients under orthodontic treatment. The elastic chains stayed with an initial force of 150 grammas during 3 weeks and the force displayed by the chains measured in the first 24 hours, one week and 3 weeks. All samples suffered relaxation of the initial force. In the first 24 hours, the degradation measured was from 5. 5% to 37. 66%. In one week, from 8. 16% to 44. 5% and in three weeks, from 12. 33 to 47. 33%. In the end of the evaluation, all the elastic chains presented necessary forces to move teeth. / As cadeias elásticas são amplamente utilizadas pelos ortodontistas devido à sua facilidade de uso, ao conforto ao paciente, à praticidade na higienização e ao baixo custo. No entanto, por causa da absorção de líquidos e de outros fatores, como mudanças na temperatura, elas sofrem deformação permanente e degradação das forças geradas inicialmente. As tecnologias empregadas para a fabricação das cadeias elásticas e os materiais utilizados definem a velocidade e a quantidade de degradação de força que estes materiais irão sofrer quando distendidos em meio bucal. A fim de avaliar a degradação de força de cadeias elásticas de seis fabricantes, foi colocado um dispositivo preso ao aparelho fixo de 20 pacientes em tratamento ortodôntico, onde segmentos, com quatro elos cada, destas cadeias elásticas ficaram distendidos com uma força inicial de 150 gramas pelo período de 3 semanas. Mediu-se a força alcançada pelas cadeias no intervalo de 24 horas, uma semana e três semanas. Todas as marcas comerciais avaliadas sofreram degradação de força estatisticamente significante já na primeira medição, que variou de 5,5% a 37,66%. No final da primeira semana, a variação foi de 8,16% a 44,5% e, no final das três semanas, de 12,33% a 47,33%. Ao término do experimento, todos apresentavam forças suficientes para a movimentação dentária.
307

Avaliação de propriedades mecânicas de resinas compostas nanoparticuladas

Balbinot, Carlos Eduardo Agostini January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:22Z (GMT). No. of bitstreams: 2 000387549-0.pdf: 9945748 bytes, checksum: 2dfadcd5259cb6d75417400392f79458 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was evaluate selected mechanical properties (compressive strength, diametral tensile strength, flexural strength e flexural moduli) of four differents nanofilled composite and a microhybrid composite, in dentin e enamel A2 shades. Were maded ten samples for each group of each test. The flexural moduli was calculated by the results of the flexural strength`s test. The results were compared statistically with ANOVA e Tukey (p<0,01). There was no statistical difference for compressive strength, with values that range into 141. 04 MPa for 4 Seasons A2E and 206. 08 MPa Grandio A2O. For flexural strength, there was statistical difference for the tested groups, and the values range into 59. 16 MPa for 4 Seasons A2E and 122 MPa for Supreme XT A2E. There was statistical difference for flexural moduli and in this test the values range between 3. 4 GPa for 4 Seasons A2E and 13. 30 GPa for Grandio A2O. For diametral tensile strength, Esthet-X A2O showed value (34. 87 MPa) statiscally lower than the others groups, and Supreme XT A2E (50. 26 MPa), statiscally higher than the others tested groups; between the others groups there was no statistical difference. Even with differences for the values between the tested groups for flexural strength, flexural moduli and diametral tensile strength, the nanofiller composites, based in the results of this study, present mechanical properties similar from microhibrid resin. / Este estudo teve como objetivo avaliar as propriedades mecânicas selecionadas (resistência à compressão, resistência à tração diametral, resistência flexural de trêspontos e módulo flexural) de quatro marcas diferentes de resina composta nanoparticuladas e uma resina composta microhíbrida, nas cores A2 esmalte e dentina. Foram confeccionadas dez amostras para cada grupo de cada teste. O módulo flexural foi calculado a partir dos resultados do teste de resistência flexural. Os resultados obtidos nos ensaios foram comparados estatisticamente com análise de variância e teste de Tukey (p < 0,01). Não houve diferença estatisticamente significante para os grupos testados no teste de resistência à compressão, sendo que as médias variaram entre 141,04 MPa para a resina 4 Seasons A2E e 206,08 MPa para a resina Grandio A2O. No teste de resistência flexural, houve diferença estatisticamente significativa entre os grupos, onde as medias variaram entre 59,16 MPa para a resina 4 Seasons A2E e 122 MPa para a resina Supreme XT A2E. Houve diferença estatisticamente significante para módulo flexural e neste teste as médias variaram entre 3,4 GPa para a resina 4 Seasons A2E e 13,30 GPa para a resina Grandio A2O. No teste de resistência à tração diametral, a resina Esthet-X A2O apresentou média (34,87 MPa) estatisticamente menor que os demais grupos, e a resina Supreme XT A2E (50,26 MPa), estatisticamente maior que os demais grupos testados; entre os demais grupos não houve diferença estatisticamente significante. Apesar de diferenças nos valores entre os grupos testados nos testes de resistência flexural, módulo flexural e resistência à tração diametral, as resinas nanoparticuladas, baseados nos resultados obtidos neste estudo, apresentam propriedades mecânicas semelhantes da resina microhíbrida.
308

Toxicidade da solda de prata utilizada em ortodontia: estudo "in vitro" e "in situ"

Freitas, Maria Perpétua Mota January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:26Z (GMT). No. of bitstreams: 2 000402872-0.pdf: 99141 bytes, checksum: 5dc4125b2c78cb76226d6ed213f92959 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study aimed to evaluate the toxicity of silver solder used in Orthodontics through an “in vitro” cytotoxicity test as well as to determine the “in situ” concentration of component ions of the silver solder released in human saliva. The cytotoxicity assay was performed by fibroblast culture, line NIH/3T3, being divided in 4 groups (n=10, each): control, negative control (stainless steel wire), positive control (amalgam discs) and silver solder. After the cell culture in complete D-MEM and obtained a confluence of 80% the suspension was added on the plaques of 24 wells with the samples and incubated at 37° C for 24 hours. The plaques were then evaluated in an inverted optical microscope and micrographs were taken. Results were recorded in answer indexes according to modifications in the Stanford parameters (1980), based on the size of the diffusion halo of the toxic substance and amount of cell lysis. The results showed a maximum rate response to the silver solder group, as well as severe inhibition of the proliferation and cell growth, more circular cells and, most of them having with a darkened and granular aspect, suggesting lysis with cell death, results comparable to the positive control. In the “in situ” study the sample consisted of 60 subjects, aged from 8 to 14 years, divided in 2 groups (n=30, each): control and test (patients requiring the use of Hyrax appliances). To analyze the release of metallic ions, saliva samples were collected from each patient at 6 different moments for both groups: initial, 10 minutes, 24 hours, 7, 30 and 60 days after the insertion of the Hyrax appliance. Saliva was examined through Atomic Absorption Spectrophotometry with Graphite Furnace as to the presence of ions cadmium, copper, zinc and silver. The non-parametric Friedman and Mann-Whitney tests were used for the statistical analysis (p<0. 05). In the control group the ionic concentrations showed low values for cadmium, copper and zinc (p>0. 05), while the silver ion wasn’t detected. As for the test group, all subjects showed significant concentrations at 10 minutes post- insertion of the appliance (p<0. 01), higher averages for copper were detected, tending to reduce after 24 hours. The comparison between the groups showed significant differences for copper (all moments), zinc (10 minutes, 24 hours, 7days and 30 days) and for cadmium, only for 10 minutes. It was concluded that the silver solder was a material of high cytotoxicity to the studied cells. The differences in ionic concentrations in the groups and between them showed clearly the influence of individual physiological and metabolic characteristics of the human oral cavity on the alloys used in orthodontic appliances and corrosive process; as well as there was great release of ions with high concentrations immediately after the appliance insertion, representing risk of absorption and retention of these ions by the human body despite the decline in concentrations during the period studied. / Propôs-se neste trabalho avaliar a toxicidade da solda de prata utilizada em Ortodontia por meio do teste de citotoxicidade "in vitro", bem como pela determinação "in situ" da concentração dos íons componentes da solda de prata, liberados na saliva humana. O ensaio de citotoxicidade foi por meio de cultura de fibroblastos, linhagem NIH/3T3, sendo montados 4 grupos (n=10, cada): controle, controle negativo (fio de aço inoxidável), controle positivo (discos de amálgama) e (solda de prata). Após o cultivo das células em meio D-MEM completo e obtida confluência de 80%, a suspensão foi adicionada sobre as placas de 24 poços, contendo os corpos de prova, sendo incubados em estufa a 37ºC, por 24 horas. Após esse período, as placas foram avaliadas em microscópio óptico invertido, fotomicrografadas e os resultados registrados em índices de resposta, a partir de modificações nos parâmetros de Stanford (1980), baseados no tamanho do halo de difusão da substância tóxica e quantidade de lise das células. Os resultados mostraram índice de resposta máximo para o grupo da solda de prata, bem como severa inibição da proliferação e crescimento celular, células mais circulares e, em grande parte, com aspecto escurecido e granular, sugerindo lise com morte celular, resultados comparáveis ao controle positivo. No estudo "in situ", a amostra foi composta por 60 indivíduos entre 8 e 14 anos, divididos em 2 grupos (n=30, cada): controle e teste (necessidade de uso do aparelho de Hyrax).Para análise da liberação dos íons metálicos, foram coletadas amostras da saliva de cada paciente, em 6 tempos, para ambos os grupos: inicial, 10 minutos, 24 horas, 7, 30 e 60 dias pós-instalação do aparelho. A avaliação da saliva foi realizada por meio de Espectrofotometria de Absorção Atômica com Forno de Grafite, determinando-se a concentração dos íons cádmio, cobre, zinco e prata. Para análise estatística, foram utilizados os testes não-paramétricos de Friedman e Mann-Whitney, com p<0,05. As concentrações iônicas, no grupo controle, mostraram valores baixos para o cádmio, cobre, zinco (p>0,05) e, principalmente para a prata, onde não atingiram limite de detecção. No grupo teste, todos os íons mostraram concentrações expressivas aos 10 minutos pós- instalação do aparelho (p<0,01), maiores médias para o cobre, com tendência à redução após 24 horas. A comparação entre os grupos mostrou diferenças significativas para o cobre (todos os tempos), zinco (10 minutos, 24 horas, 7 e 30 dias) e, para o cádmio, apenas aos 10 minutos. Concluiu-se que a solda de prata representa um material de alta toxicidade para as células estudadas; as diferenças nas concentrações iônicas intragrupos e intergrupos mostraram, nitidamente, a influência das características fisiológicas e metabólicas individuais da cavidade oral humana sobre as ligas utilizadas nos aparelhos ortodônticos e processo corrosivo desencadeado, assim como foi perceptível a grande liberação dos íons, com concentrações elevadas imediatamente após a instalação do aparelho, representando risco de absorção e retenção desses íons pelo organismo humano, apesar da regressão nas concentrações, ainda no período estudado.
309

Avaliação da citotoxicidade de materiais endodônticos no tratamento de perfurações radiculares

Carneiro, Débora Ferreira 19 July 2010 (has links)
Tese (doutorado)-Universidade de Brasília, Faculdade de Ciências da Saúde, 2010. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-03-18T18:48:09Z No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2011-03-19T19:55:48Z (GMT) No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5) / Made available in DSpace on 2011-03-19T19:55:48Z (GMT). No. of bitstreams: 1 2010_DeboraFerreiraCarneiro.pdf: 2035586 bytes, checksum: ee9d140bc73a527e588a16ce8b998da1 (MD5) / Perfurações radiculares podem ser seladas com auxílio de materiais endodônticos, que ficam em contato direto com as células do ligamento periodontal, podendo causar danos que retardem ou impeçam o processo de reparo. Os objetivos deste trabalho foram avaliar a citocompatibilidade dos extratos dos materiais endodônticos (Endofill, Sealer 26, cimento de Portland branco e Cimento de óxidos bioativos), recém espatulados e após 24 horas de presa, em contato com células do ligamento periodontal humano. Foram utilizados como parâmetros de análise a capacidade de proliferação, o potencial transmembrânico mitocondrial, as alterações morfológicas, o potencial genotóxico e as alterações no ciclo celular. As células do ligamento periodontal foram obtidas a partir da extração de quatro terceiros molares e cultivadas em laboratório, conforme protocolos de cultura de células. As análises dos efeitos foram realizadas por meio do teste MTT de viabilidade celular, análise microscópica e a citometria de fluxo utilizando como fluorocromos rodamina 123 e iodeto de propídio. O pH foi avaliado pela medição imediata do meio de cultura com extrato do cimento endodôntico com auxílio de pHmetro calibrado. Os resultados obtidos, após análise estatística (ANOVA a três fatores, com nível de significância p<0,05), revelaram que a composição dos materiais é o fator mais influente nas alterações celulares. Todos os materiais demonstraram algum grau de toxicidade para as células do ligamento periodontal dependendo da análise realizada. Somente o Endofill demonstrou toxicidade em todos os testes. Cimento de óxidos bioativos e o cimento de Portland branco não causaram alterações no potencial transmembrânico mitocondrial. Sealer 26, Sealer  e Cimento de Portland branco aumentaram o pH do meio e os dois primeiros também provocaram alterações morfológicas. Cimento de óxidos bioativos foi o que causou os menores danos ao DNA celular e, portanto, as menores alterações em ciclo celular. A citotoxicidade tende a diminuir à medida que a reação presa se completa. Apesar dos resultados, faz-se necessário continuar as pesquisas, com organismos vivos, para predizer e estabelecer a compatibilidade dos materiais. _______________________________________________________________________________ ABSTRACT / Root perforations can be sealed with the aid of endodontic materials, which are in direct contact with the periodontal ligament cells, may cause damage to slow or prevent the repair process. Our objectives were to evaluate the cytocompatibility of the extracts of endodontic materials (Endofill, Sealer 26, white Portland cement and bioactive oxides-based sealer), after contact for 24 hours with human periodontal ligament cells. The cell viability, the mitochondrial transmembrane potential, the morphological changes, the genotoxic potential and changes in the cell cycle were evaluated by MTT assay and flow cytometry. The periodontal ligament cells were obtained from the extraction of four third molars and cultured in the laboratory by cell culture protocols. The pH was measured at the material extract at varying time intervals with calibrated pHmeter. The results, after statistical analysis (ANOVA with three factor interaction, p <0.05), revealed that the composition of materials is the most influential factor in the cellular changes. All materials showed some degree of toxicity to the cells of periodontal ligament depending on the analysis. Only Endofill demonstrated toxicity in all tests. Bioactive oxides-based sealer and white Portland cement did not cause changes in mitochondrial transmembrane potential. Sealer 26, Sealer  and white Portland cement increased the pH of the medium and the first and second also caused morphological changes. Bioactive oxide-based sealer was what caused the least damage to cellular DNA and thus the smallest changes in the cell cycle. The cytotoxicity tends to decrease as the set reaction is complete. Despite the results, it is necessary to continue research with living organisms to predict and establish the compatibility of materials.
310

Estudo Prospectivo da Associação entre Polimorfismos Ligados à Remodelação Óssea e o Insucesso de Implantes Dentários

Texeira, Camila Epitácio Cravo 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-08T17:56:32Z No. of bitstreams: 2 DISSERTAÇÃO Camila Eptácio Cravo Teixeira.pdf: 619895 bytes, checksum: db1cbb0b8e535192f130230b48c0357f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-08T17:56:32Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Camila Eptácio Cravo Teixeira.pdf: 619895 bytes, checksum: db1cbb0b8e535192f130230b48c0357f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014 / CNPq / Objetivos: Verificar a relação entre polimorfismos genéticos ligados às citocinas da remodelação óssea osteoprotegerina (OPG) e o ligante do ativador do receptor do fator nuclear kappa B (RANKL), relacionar a presença de polimorfismos em OPG e RANKL com o insucesso clínico dos implantes dentários ao longo do tempo e determinar quais combinações de polimorfismos de OPG e RANKL estão associados ao insucesso de implantes dentários. Materiais e métodos: Vinte pacientes de ambos os sexos, maiores de dezoito anos, reabilitados no total com trinta e quatro implantes dentários e avaliados a cada seis meses durante um ano participaram do estudo. Após o exame clínico e radiográfico, os pacientes foram divididos no grupo de insucesso dos implantes, caso um ou mais do seguintes critérios fossem encontrados: mobilidade; queixas subjetivas persistentes; infecção peri-implantar recorrente com supuração; radiolucência contínua ao redor do implante; profundidade de sondagem ≥ 5mm e sangramento à sondagem; e grupo de sucesso, se nenhuma das características acima fossem identificadas. Foi coletado sangue periférico para a análise do polimorfismo das citocinas de OPG e RANKL através da reação em cadeia da polimerase (PCR). Resultados: Não houve diferença estatisticamente significante entre o grupo de falha dos implantes em relação ao genótipo de OPG e RANKL. Conclusão: Os polimorfismos de OPG e RANKL não influenciam no insucesso dos implantes dentários ao longo do tempo de estudo.

Page generated in 0.2738 seconds