• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Avaliação da influencia da nicotina sobre o reparo osseo ao redor de implantes de titanio com diferentes tratamentos de superficie colocados em tibias de coelhos

Stefani, Cristine Miron 17 August 2001 (has links)
Orientador: Francisco Humberto Nociti Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T10:59:34Z (GMT). No. of bitstreams: 1 Stefani_CristineMiron_D.pdf: 2230659 bytes, checksum: 65f2d179832aebbd74d049ecbf00415b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a influência da nicotina sobre o reparo ósseo ao redor de implantes de titânio com diferentes tratamentos de superfície colocados em tíbias de coelhos. Trinta e dois coelhos Nova Zelândia, adultos, fêmeas, sob anestesia geral, receberam dois implantes de titânio em cada tíbia, sendo dois usinados e dois jateados com óxido de alumínio. Os animais foram sorteados para receber um dos seguintes tratamentos: a) solução fisiológica, b) 0,18 mg de nicotina /Kg de peso corporal/dia; c) 0,56 mg/Kg/dia; d) 0,93 mg/Kg/dia, através de injeção subcutânea. Após a inserção dos implantes, aos sete e 14 dias, receberam aplicação intramuscular de solução de calceína a 2%, para marcação do tecido ósseo neoformado. Os animais foram sacrificados 42 dias após a colocação dos implantes. Secções não descalcificadas foram avaliadas histometricamente e através de microscopia de fluorescência para os parâmetros: intensidade da marcação do tecido ósseo neoformado, área relativa do tecido ósseo por rosca do implante e extensão relativa de tecido ósseo em contato direto com a superfície do implante. Os dados obtidos foram comparados estatisticamente pelo teste ANOV A. Houve diferença estatística significativa (p=0,015) para o parâmetro extensão do tecido ósseo em contato direto com a superfície do implante entre os implantes com superfície tratada quando comparados aos de superfície usinada, para os grupos que receberam nicotina C e D (37,85% +- 8,85 e 30,13% +- 4,97; 33,13% +- 8,87 e 27,79% +- 3,93, respectivamente). Dentro das condições experimentais empregadas, foi possível concluir que a nicotina não influenciou o reparo ósseo ao redor dos implantes de titânio para os parâmetros avaliados. E implantes com superfície tratada favoreceram a extensão de tecido ósseo em contato direto com a superfície do implante nos animais tratados com nicotina / Abstract: The present study investigated the possible influence of nicotine on the bone healing process around machined and rough surfaced titanium implants inserted in the tibiae of rabbits. Thirty-two female New Zealand rabbits were included. After anesthesia, the tibiae surface was exposed and two screw-shaped commercially available pure titanium implants 7.0 mm in length and 3.75 mm in diameter were placed bilaterally. A total of 128 implants were inserted: 64 with a rough surface rnish (aluminum oxide blasted) and 64 with a machined surface finish. The animals were randomly assigned to one of the four treatment groups, including daily subcutaneous injections of nicotine: a) saline solution, b) 0.18 mg/Kg, c) 0.56 mg/Kg and d) 0.93 mg/Kg. In order to label regenerated bone a 2% calcein green solution was administered by intramuscularly injection at O, 7, 14 days after implant insertion. After 42 days, the animals were sacrificed and undecalcified sections were prepared. The degree of bone contact with the implant surface, the bone area and the intensity of bone labeling were measured into the limits of the threads of the implant. Two way ANOV A were used to compare the results. Statistically significant difference was found for the degree of bone contact with the implant surface between smooth and rough surfaces finishes for C and D groups (30,13% +- 4,97 and 37,85% +- 8,85; 27,79% +- 3,93 and 33,13% +- 8,87, respectively, P=0,015). Within the limits of the present study, it was concluded that nicotine had no effect on the bone repair around titanium implants inserted in rabbit tibiae, and rough surfaced. In implants improved bone/implant contact for nicotine groups / Doutorado / Periodontia / Doutor em Clínica Odontológica
322

Implantes dentais imediatos associados a utilização de uma combinação do fator de crescimento derivado de plaquetas (PDGF) e fator de crescimento semelhante a insulina (IGF-1) : analise histometrica em cães

Stefani, Cristine Miron 10 April 1999 (has links)
Orientador: Francisco Humberto Nociti Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T16:33:06Z (GMT). No. of bitstreams: 1 Stefani_CristineMiron_M.pdf: 3647273 bytes, checksum: 0b66f43d875767c639ec815978074434 (MD5) Previous issue date: 1999 / Resumo: o objetivo deste estudo foi avaliar histometricamente em cães, a utilização de uma combinação do fator de crescimento derivado de plaquetas (PDGF) e fator de crescimento semelhante à insulina - 1 (IGF-1) ffente à colocação de implantes dentais imediatos. Oito cães adultos foram utilizados neste estudo. Sob anestesia geral, os segundos, terceiros e quartos pré-molares inferiores (P2, P3, P 4) foram extraídos e os alvéolos mesiais de P3 e P 4 dos dois lados da mandíbula receberam implantes dentais de titânio. Aleatoriamente foram determinados o lado teste e o controle, sendo que para o lado teste os implantes receberam 0,10 m1 de gel de metilcelulose a 4%, contendo 5 ~g/m1 de cada um dos fatores PDGF e IGF-1 antes de sua colocação, enquanto os implantes do lado controle receberam apenas 0,10 m1 de gel de metilcelulose a 4% (placebo). Os cães receberam injeção de solução de calceína verde nos períodos de O, 7, 15, 30, 45, 60, 75 e 90 dias para marcação do tecido ósseo neoformado. Os animais foram sacrificados nos períodos de 3, 8 e 12 semanas após a colocação dos implantes. Secções não descalcificadas foram avaliadas histometricamente para as variáveis área de tecido ósseo por rosca do implante, extensão do tecido ósseo em contato direto com a superfície do implante dental e intensidade da marcação do tecido ósseo neoformado. Os dados obtidos foram comparados estatisticamente pelo teste t de Student «.(=0,05) entre os grupos teste e controle para cada tempo experimental e pelo ANOV A nas comparações intragrupos «.(=0,05). Encontrou-se diferença estatística significativa (p=0,002549) para o parâmetro extensão do tecido ósseo em contato direto com a superfície do implante dental entre os grupos teste (22,4 :!: 13,7%) e controle (17,2 :!: 13,6%) no tempo 3 semanas; e entre 3 e 12 semanas (127,8 :!: 42,59 e 56,7 :!: 26,34 respectivamente, em escala de cinzas) para o grupo. teste na variável intensidade da marcação do tecido ósseo neoformado. Ao final do estudo concluiu-se que a combinação de PDGF e IGF-I, dentro das condições experimentais empregadas, demonstrou participação positiva no período inicial da reparação óssea / Abstract: The purpose of the present study was to evaluate bone repair around dental implants placed into immediate extraction sockets, associated or not with local application of a combination of platelet derived growth factor (pDGF) and insulin like growth factor - 1 (IGF-1) on the imp1ant surface. Eight adult dogs were used. Under sodium pentobarbithal inserted bilatera1ly. Before implantation, two of the four implants received a single application of 5~g/m1 ofPDGF and IGF-1 delivered in 0,10 m1 of 4% methylcellulose gel. During the experimental period a 2% calcein green solution was administered O, 7, 15, 30, 45, 60, 75 and 90 days after implant insertion. The animals were sacrificed by a lethal injection of sodium penthobarbital in the periods of 3, 8 and 12 weeks after implant insertion. Undecalcified sections were obtained, submitted to histometric analysis and the results analysed by statistical t test (a=O,05) and ANOV A in intragroups analyses (a=0,05). Statistically different results between test and control groups (22,4 i: 13,7 and 17,2 i: 13,6%, respectivelly) were observed for bone/implant contact at 3 weeks timepoint and for intensity of labelled new bone between 3 and 12 weeks (127,8 i: 42,59 and 56,7 i: 26,34, gray scale values) intragroup for test group. It was concIuded that the combination of PDGFIIGF-1 at present experimental conditions activelly took part of the inicial phase of bone repair / Mestrado / Periodontia / Mestre em Clínica Odontológica
323

Influencia do substrato dentinario e do material restaurador na infiltração marginal de restaurações cervicais

Saito, Solange Katia 08 January 2001 (has links)
Orientador : Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:46:19Z (GMT). No. of bitstreams: 1 Saito_SolangeKatia_D.pdf: 2022044 bytes, checksum: 1448f462721703745289700cf45f625b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar, quantitativamente, a infiltração marginal de diferentes sistemas restauradores, quando colocados em substrato dentinário normal ou hipermineralizado artificialmente. Cento e oito cavidades foram confeccionadas em raízes de dentes bovinos e divididas em dois grupos experimentais (normal ou hipermineralizado), sendo subdivididas em quatro grupos, conforme o sistema restaurador utilizado: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 e Clearfil SE Bond/Filtek Z250. A dentina foi hipermineralizada nas soluções: 1,5M de cálcio (CaCl2H2O, pH 5,7) por 1 hora e 1,5M de fosfato (K2HPO4, pH 9,5) por mais 1 hora, sendo, estocados em saliva artificial {1,5mM de cálcio (CaCl2H2O)+ 0,9mM de fosfato (K2HPO4)+ 0,15M de KCI; pH 7,0} por 24 horas, após a realização dos preparos cavitários. Os sistemas restauradores foram colocados em dentina hipermineralizada (Grupos I, ID, V e VII) e dentina normal (Grupos II, IV, VI e VllI). Os dentes restaurados foram submetidos a 1000 ciclos térmicos, entre temperaturas de 5 e 55±2°C. Em seguida, foram imersos em solução de azul de metileno a 2% por 24 horas. As amostras foram trituradas e o pó diluído em 4 ml de álcool absoluto. A infiltração marginal foi determinada e expressa em concentração de corante (ml). Os dados analisados pelos testes de Kruskal-Wallis e Ryan mostraram que não houve diferença estatística entre substrato; no entanto, houve diferença significante entre os materiais (p<0,01). Os resultados obtidos foram (mg/mI): GI-55,9a; GII-64,3a; GIII-12,lb; GIV-2I,2b; GV-32,9bc; GVI 30,lbc; GVll-41,9cd; GVIII-37,7cd. A microinfiltração relacionada com Vidrion R caps foi maior quando comparada com a dos outros materiais. As cavidades restauradas com Vitremer apresentaram valores de infiltração marginal semelhante ao sistema Single Bond/Filtek Z250 e este não diferiu do sistema Clearfil SE Bond/Filtek Z250 / Abstract: The aim of this study was to evaluate, quantitatively, the marginal leakage around different esthetic materials placed on normal and artificially hypermineralized cervical dentin cavities. One hundred eight cavities were prepared in bovine teeth roots and divided in two experimental groups (normal or hypermineralized), then subdivided in four subgroups according to the restorative system: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 and Clearfil SE Bond/Filtek Z250. Dentin was hypermineralizing into the solutions contained: 1,5M calcium (CaCl2H20, pH 5,7) for 1 hour and 1,5M phosphate (K2HPO4, pH 9,5) for more 1 hour and then, stored in synthetic saliva {1,5mM calcium (CaCl2 H2O)+ 0,9mM phosphate (K2HPO4)+ 0,15M KCI; pH 7,0} for 24 hour, after cavities preparation. The restorative materials were placed in hipermineralized dentin (Groups 1, m, V and Vll) and normal dentin (Groups lI, IV, VI and VID). The restored teeth were submitted to 1000 thermal cycles between 5±2 °C and 55±:2 °C, then imersed in to 2% methylene blue solution for 24 hours. The samples were triturated and the powder were placed into absolute alcohol to dye extraction. The marginal leakage was determined and expressed by dye concentration (mm/ml). Data were analysed by the Kruskal-Wallis and Ryan test. The results were (mm/ml): GI- 55,9a; G-II 64,3a; G-III 12,lb; G-IV 21,2b; G-V 32,9bc; G-VI 30,lbc; G-VII 41,900; G-VIII 37,7cd. There was no statistically significant difference between the evaluated substrates; however, there was significant difference among materials (p<0,01). Microleakage related to Vidrion R caps material was greater than that any other material. Vitremer material presented the same marginalleakage values as Single BondIFiltek Z250. The latter didn't differ from Clearfil SE Bond system / Doutorado / Dentística / Doutor em Clínica Odontológica
324

Avaliação da contração de polimerização e das tensões promovidas em função de deferentes sistemas de polimerização e de materiais restauradores estéticos

Lawrence Gonzaga Lopes 11 July 2003 (has links)
O objetivo deste trabalho foi avaliar a contração de polimerização e as tensões promovidas, no sentido de comparar o sistema de fotopolimerização por LED (130 mW/cm2) com o sistema halógeno na forma convencional (60 s – 600 mW/cm2) e pulso de fotopolimerização (3s – 200 mW/cm2 / 3 minutos / 59 s – 600 mW/cm2). Da mesma forma, categorias distintas de resinas foram comparadas, como: resina híbrida (Z100 - 3M); resina de micropartículas (A110 – 3M); resina “condensável” (SureFil – Dentsply); e resina composta de ativação química (Bisfil II – Bisco). Para medir a contração de polimerização foram confeccionados cinco espécimes para cada condição experimental, obtidos pela inserção da resina em um anel de silicona com um diâmetro interno de 5mm e altura de 2mm. Um extensômetro elétrico (strain gauge), localizado abaixo da resina, registrou a deformação do material em função da contração de polimerização. Nessa mesma proposição, as tensões decorrentes da contração de polimerização foram medidas pelo método de fotoelasticidade. Para isto, foram confeccionados modelos com material transparente, contendo uma cavidade tipo Classe I, com 5mm de comprimento X 2mm de profundidade X 3mm de largura. Foram realizados sete corpos-de-prova para cada condição experimental. Após a inserção e polimerização da resina, secções com 2mm de espessura foram obtidas e avaliadas sob microscópio de luz polarizada, a fim de se verificar as franjas isocromáticas, que representavam as tensões formadas. Os dados referentes à contração de polimerização foram submetidos ao teste paramétrico de análise de variância a dois critérios (ANOVA) e, a um critério para os referentes ao teste de fotoelasticidade, seguido pelo teste de Tukey (p£0,05). Assim, foi observado que o sistema químico de ativação (Bisfil 2B) produziu os menores valores de contração de polimerização e de tensões; de forma geral, a técnica pulso interrompido reduziu os valores de contração de polimerização das resinas compostas e de tensões geradas, quando comparado com às técnicas convencionais (LED e Luz Halógena); a fonte de luz à base de LEDs produziu menores valores de contração de polimerização do que a fonte halógena, quando aplicados convencionalmente. Entretanto, o LED proporcionou a mesma quantidade de tensões de contração de polimerização, quando comparado à fonte de luz halógena (técnica convencional); de maneira geral e independente do meio de fotoativação, a resina SureFil produziu os menores valores de contração de polimerização e de tensões geradas, dentre as fotoativadas. Por outro lado, as resinas Z100 e A110 geraram maiores valores de contração e de tensões. / The aim of this work was to evaluate the polymerization shrinkage and stress, comparing the LED light source (130 mW/cm2) with quartz tungsten halogen (QTH) light source in the conventional mode (60s – 600 mW/cm2) and pulse delay curing mode (3s – 200 mW/cm2 + 3 min + 59s – 600 mW/cm2). Different categories of composite resins were also evaluated, such as Z100 (hybrid), A110 (microfilled), SureFil (‘packable”) and Bisfil 2B (chemical-cured resin). Silicone molds 2 mm high and 5 mm diameter were used to prepare five specimens for each experimental condition. A strain gauge located under the resin measured the material deformation due to polymerization shrinkage. The stresses were measured by photoelasticity analysis. Butt-joint box-shaped cavities (5.0 X 3.0 mm, 2.0 in depth) were prepared in photoelastic transparent resin. Seven specimens were made for each condition. After the insertion and polymerization of the composite resin, they were cross-sectioned perpendicularly to the longitudinal side of the cavity to determine, under polarized microscopic, the contraction stress by means of the observation of fringes in the photoelastic mould walls, which represented the created stress. The shrinkage data were statistically evaluated using two way ANOVA and Tukey tests (p£ 0.05) and for stress data one way ANOVA and Tukey tests (p£ 0.05) were used. It was observed that the chemical-cured system (Bisfil 2B) produced the lower means of polymerization shrinkage and stress; in general, the pulse delay mode reduced the contraction and the stress values when compared to conventional curing modes (LED and QTH); the LED light source produced lower contraction values than QTH light source, when used in conventional mode. However, the LED light source generated the same as stress QTH light source (conventional mode); in general, and independently of the activation mode, the SureFil resin produced lower contraction and stress values than others light-cured resins. Conversely, the Z100 and A110 resins produced the greater contraction and stress values.
325

Efeito da ciclagem de pH na liberação/recarga de flúor e na microinfiltração de materiais restauradores resinosos

Rosa Maria Viana de Bragança Garcez 26 June 2006 (has links)
Quedas cíclicas de pH no meio bucal parecem ser um dos maiores desafios aos quais estão expostos os materiais restauradores. Desta forma, a capacidade de liberação/recarga de flúor (F¯) e a avaliação da interface dente/restauração pelo teste de microinfiltração em ciclagem de pH (CpH), durante 15 dias, pode complementar in vitro, a simulação de situações clínicas de alto desafio cariogênico. Foram confeccionados 12 corpos-de prova na forma de discos (1,1 cm de diâmetro, 0,15 cm de espessura) dos materiais, distribuídos em dois grupos sem e com recarga (R), Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR). Os corpos-de-prova foram imersos individualmente em 4 mL de solução CpH, 6 horas em solução desmineralizante (DES¯) e 17 horas em solução remineralizante (RE). A recarga foi iniciada no 2º dia com pasta fluoretada fluida 3:1(Crest), realizada diariamente, entre as trocas das soluções DES¯/RE. As soluções DES¯/RE dos dois grupos, com e sem recarga eram trocadas diariamente, e armazenadas durante 15 dias. A análise da concentração de F¯ da liberação e da recarga foi medida com 0,5 mL de solução teste adicionada a igual volume de TISAB II, por um eletrodo íon F¯ específico acoplado ao aparelho analisador pH/F¯. Os resultados foram submetidos a ANOVA e teste de Tukey (p<0,05). Os maiores valores F¯ foram registrados em solução DES¯ (pH 4.3). Todos os materiais, em ambos experimentos, apresentaram o mesmo padrão de liberação de F¯ e, os maiores valores foram do V (418,04 µgF¯/cm²) e VR (818,39 µgF¯/cm²). Ao 3º dia, materiais sob recarga apresentaram maiores valores de F¯ liberado, com declínio lento e alcançando valores estáveis ao 15º dia, quando os valores de F¯ aproximaram-se aos sem recarga, obtidos ao 2º dia. As resinas compostas D e TC apresentaram os mais baixos valores de F¯ liberados, D (5,16 µgF¯/cm²); DR (10,25 µgF¯/cm²); TC (10,09µgF¯/cm²); TCR (16,85 µgF¯/cm²), em ambos experimentos, mas sem diferenças estatísticas significantes entre DR e TC. Entre as resinas compostas, a maior liberação foi da AR (327,20 µgF¯/cm²). Para avaliar a microinfiltração, foram utilizados 3ºs molares extraídos preparados com cavidades Classe V (4,00 mm, 2,00 mm, 1,5 mm), em esmalte, restaurados com os mesmos materiais e distribuídos em dois meios de imersão, água deinozada (A) e CpH (DES¯/RE) durante 15 dias. Em seguida, foram imersos em fucsina básica 0,5% por 24 horas, lavados, seccionados, visualizados em estereomicroscópio óptico com 60X de aumento. Os cortes mais infiltrados foram escaneados e uma medida linear (0,5 cm=115 pixels) foi obtida pelo softweare Image Tool. Ao teste de Tukey, houve diferença estatística significante entre os meios de imersão, o maior grau de microinfiltração foi em CpH. Todos os materiais apresentaram microinfiltração na interface dente/restauração, sendo observada a maior infiltração na resina composta D, seguida da TC, V, DY e A. Entretanto, não houve diferença estatisticamente significante entre os materiais TC, V, DY e A. Diante das limitações desse estudo e frente aos resultados encontrados, observa-se que apesar das quantidades de F¯ liberadas no experimento sem e com recarga, não deixou de ocorrer o processo de microinfiltração na interface dente/restauração dos materiais avaliados. / pH cyclic alterations in the oral environment seems to be one of the largest challenges in which the restoratives materials are subjected. Therefore, fluoride (F¯) release/uptake capacity evaluation of the tooth/restorative interfaces by microleakage test under pH-cycling (CpH) regimen, for 15 days might simulate in vitro the clinical situations of caries challenging. Twelve cylindrical samples with diameter of 11mm and thickness of 1.5mm of the materials Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR) were fabricated and distributed in two groups of F¯ release and uptake. Samples were individually immersed in 4mL of CpH solution, i.e., 6 hours in demineralizing solution (pH 4.3) followed by 17 hours in remineralizing solution (pH 7.0). The fluoride uptake was started at 2nd day by means of dentifrice slurry containing 1.100 ppm of F¯ (Crest), applied daily, before DES¯/RE solutions changing. The analysis of F¯ release/uptake concentration was measured by a specific F¯ ionelectrode with 0.5mL of test solution added to 0.5mL of TISAB II. The results were submitted to ANOVA and Tukey\'s Test (p<0.05). The highest F¯ values were registered in DES¯ solution. All materials, in both experiments, presented the same pattern of fluoride release and the highest rates were obtained by V (418.04µgF¯/cm²) and VR (818.39µgF¯/cm²) groups. At 3rd day, all materials presented the highest amount of F¯ releasing after the uptake, with slowly decrease, reaching stable values at the 15th day, when fluoride release presented similar levels of that at 2nd day. Composite resins D and TC released the lowest fluoride amounts, D (5.16µgF¯/cm²); DR(10.25µgF¯/cm²); TC (10.09µgF¯/cm²); TCR (16.86µgF¯/cm²), in both experiments, although no statistically difference was observed between DR and TC. AR released the highest amount of F¯ (327.21µgF¯/cm²) among composites. Eighty human 3rd molars were used to evaluate microleakage under pH-cycling regimen. Class V cavities (4.0mm, 2.0mm, 1.5mm) with margins in enamel were prepared and restored with the same materials. They were distributed in two immersion media, groups: deionized water (A) 112 and pH-cycling (DES¯/RE), for 15 days. After this period, specimens were then immersed in 0.5% basic fucsine dye for 24 hours. They were washed in tap water and sectioned for evaluation. The samples were analyzed by means of an optical stereomicroscope (60X) and slices with the greatest dye penetration were choosen and submitted to Image Tool area analysis softweare. Data was submitted to stattiscal analysis using two-way ANOVA and Tukeys test (=0.05), revealing that there was statistically difference between immersion media factor. The greatest level of dye penetration was obtained in CpH. All materials tested registered some microleakage but the greatest level was registered by Definite® followed by TC, V, DY and A. However, there were no statistically significant differences amongst TC, V, DY and A. Definite® was significantly different to A and DY. Within the limits of this study and in the basis of the obtained results, the fluoride release/uptake was not able in reducing preventing the microleakage of the evaluated materials. Therefore, the restorative material to each clinical situation should be analyzed on his physical, chemical and mechanical aspects as well as his behavior under caries challenge.
326

'Creep' em resinas compostas fotopolimerizáveis. / Creep of light-cured posterior composite resins

Marcelo Guerino Pereira Couto 25 April 2000 (has links)
As resinas compostas vêm sofrendo inúmeras alterações com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles sua resistência ao desgaste e à abrasão, a contração de polimerização, a microinfiltrção marginal, e sua deformação permanente (importante propriedade em situações clínicas onde existem áreas sujeitas às forças oclusais) e esta, normalmente não é considerada. Visando determinar o “creep”, por meio da deformação permanente, amostras confeccionadas com resinas compostas fotopolimerizáveis: ALERT [A] (Jeneric®/Pentron®), CHARISMA F [C] (Heraeus/Kulzer), HELIOMOLAR RADIOPAQUE [H] (Vivadent), SOLITAIRE [S] (Heraeus/Kulzer) e TETRIC CERAM [T] (Vivadent) após armazenamento em água, à temperatura de 37 + 1ºC, foram submetidas a uma carga compressiva constante de 36MPa, por períodos de: 15 minutos, 1 hora e 24 horas. Os resultados obtidos apresentam os valores quantitativos da diferença entre o comprimento original da amostra e o seu comprimento após o ensaio, em cada período estabelecido. A análise estatística dos dados apresentados pelas cinco resinas compostas avaliadas nos quatro períodos determinados, demonstrou resultados de “creep estático” (em ordem decrescente), para o período de 15 minutos: [H] (X=1,0192%), [T] (X=0,8787%), [C] (X=0,7469%), [S] (X=0,6738%) e [A] (X = 0,5095%). Para o período de 1 hora: [H] (X=1,5546%), [T] (X=1,2082%), [C] (X=0,9744%), [S] (X=0,8245%), [A] (X=0,6348%) e, para o último período observado, 24 horas, obteve-se a seguinte seqüência: [H] (X=2,3747%), [T] (X=1,7993%), [C] (X=1,2812%), [S] (X=1,2645%) e [A] (X=0,7600). Os valores médios do “creep estático” das resinas CHARISMA F e SOLITAIRE não foram estatisticamente diferentes em qualquer um dos períodos estudados, sendo que no período de 15 minutos, os resultados obtidos para a resina TETRIC CERAM também se assemelharam aos destas e, em 1 hora, os da resina composta ALERT foram similares aos das duas primeiras; porém, a resina HELIOMOLAR RADIOPAQUE, apresentou mensurações divergentes das anteriores, demonstrando piores características de deformação permanente, por possuir maiores valores de “creep estático” em qualquer período estudado. / The posterior composite resins dental restorative materials, have been, extensively, used in substitution of dental amalgam, in function of its aesthetic best. Although the use of those resins, in areas subject to the forces occlusal, increased significantly, the nead evaluation of the behavior of “static creep”–important property to be considered in those situations–it is not very disclosed. For this reason, the objective of the present paper was to determine the “static creep” of the composite resins: Alert [A], Charisma F [C], Heliomolar Radiopaque [H], Solitaire [S] and Tetric Ceram [T], by evaluation means of the permanent deformation. That deformation was determined in specimens submitted to a constant compressive load of 36MPa, in 37 + 1ºC, immerged in recipient contend water, for periods of 15 minutes, 1 hour and 24 hours. The results obtained in that experiment present the quantitative values of the “creep” in crescent order, for the period of 15 minutes: H, T, C, S, A; in 1 hour: H, T, C, S, A and in 24 hours: H, T, C, S, A. The profile analysis of the “creep” for five composite resins evaluated in the four pre-determined periods demonstrated similar results for C, S, T in 15 minutes, A, C, S, in 1 hour and C, S for 24 hour, and different for H in every observed time.
327

Avaliação da fidelidade de troquéis de gesso obtidos de um poliéter (com a técnica do casquete) e confeccionados ou em diferentes momentos ou através de subseqüentes vazamentos num mesmo molde / Evaluation of the accuracy of stone dies obtained from a polyether mould (through shell tecnique) and made by pouring in different times or by successive pourings in a same mould.

Odirlei Arruda Malaspina 29 March 2005 (has links)
Avaliou-se, indiretamente, a fidelidade de moldes tomados (pela técnica do casquete) com o poliéter Impregum Soft, verificando-se a diferença de altura existente entre uma coroa-padrão e os respectivos troquéis de gesso Vel-Mix, obtidos utilizando-se o molde uma única vez, ou mais de uma, em diferentes idades, compondo-se assim os 5 seguintes grupos: R0/U0 – vazamento único, imediato; U1 – vazamento único, após 1 hora; U2 – vazamento único, após 2 horas; R1 - segundo vazamento, após 1 hora, e R2 - terceiro vazamento, após 2 horas. O resultado ideal seria que não houvesse diferença de altura, na porção oclusal, entre a coroa-padrão e cada troquel de gesso no qual aquela fosse adaptada. A análise estatística dos valores de desajuste detectados permitiu concluir que: 1 – Em todos os grupos, os troquéis apresentaram-se sempre maiores do que a estrutura original; 2 – O melhor resultado foi apresentado pelos troquéis dos grupos R0/U0 e U1, onde os desajustes foram respectivamente de 80,75 e 114,25 micrometros; 3 – Nos grupos R1 e R2, os desajustes foram semelhantes entre si (porém piores que os dos grupos R0/U0 e U1), com desajustes respectivamente de 153,98 e 184,54 micrometros, e 4 – Os piores resultados foram observados no grupo U2, no qual o desajuste foi de 323,36 micrometros. / The accuracy of moulds obtained through shell technique from a polyether (Impregum Soft) was indirectly evaluated, by direct evaluation of the accuracy of stone dies. A standard crown (extremely well fitted to the standard die, both presenting their oclusal portions at the same level) was used to verify the height difference between itself and each obtained Vel-Mix stone die. The condition of stone pouring lend to the name of 5 groups; some moulds were utilized (U) just once time to make a die at 3 different ages, in order to conform respectively groups UO (pouring immediately after its obtention), U1 (1 hour later) and U2 (2 hours later); the others moulds were reutilized (R), in order to conform the groups R1 (reutilized 1 hour after pouring by first time) and R2 (reutilized 2 hours after that first pouring); by analogy, the group UO could also be named RO. To quantify the referred height differences, in micrometers, a depth microscope was used. The ideal result (ideal acuraccy) would be the inexistence of such differences. Statistically treated data allowed to conclude that 1) in all groups, stone dies were allways bigger than the standard die; 2) best results were presented by specimens of groups UO/RO and U1, respectively with height difference of 80,75 and 114.25 micrometers, but without statistically significant difference; 3) groups R1 and R2, worse than the aforementioned, presented a similar performance, respectively with 153.98 and 184.54 micrometers, and 5) worse desajust was detected in group U2, with 323.36 micrometers.
328

Avaliação da Infiltração Marginal em Cavidades de Classe II Restauradas com Resina Composta Associada a Outros Materiais Restauradores.

Adriana Maria Botelho 08 July 1999 (has links)
As resinas compostas vêm sofrendo inúmeras alterações, com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles, a microinfiltração marginal. Algumas alternativas clínicas têm sido sugeridas, na tentativa de reduzir as falhas decorrentes do emprego deste material, principalmente em restaurações estendidas à região de cemento, local este onde os problemas se agravam. O objetivo deste trabalho consistiu, portanto, em estudar a efetividade do vedamento marginal de diferentes materiais aplicados no terço cervical com término em cemento para, em associação à resina composta, restaurar esteticamente cavidades de classe II, através da técnica mista, avaliandose com esta finalidade o índice de infiltração marginal tanto na interface cemento/material, quanto na interface dos materiais restauradores. Cavidades MOD com margens cervicais estendidas além da junção amelocementária foram confeccionadas em 84 dentes pré-molares humanos livres de cáries, os quais foram distribuídos em grupos de 12 elementos cada, correspondendo a 7 condições experimentais: 8 grupo 1 (controle) - Scotchbond MP/Z-100; 8 grupo 2 - verniz Copalite/Dispersalloy/Scotchbond MP/Z-100; 8 grupo 3 - Vitremer/Scotchbond MP/Z-100; 8 grupo 4 - Prime & Bond 2.1/Dyract/Scotchbond MP/Z-100; 8 grupo 5 - Prime & Bond 2.1/Dyract-AP/Scotchbond MP/Z-100; 8 grupo 6 - Stae/Freedom/ Scotchbond MP/resina composta Z-100; 8 grupo 7 - One Step/Bisfil-2B/Z-100. No sentido de evitar penetração da solução corante em áreas indesejadas, em todos os dentes os forames apicais foram obstruídos com amálgama. Após 24 horas, as restaurações foram polidas com discos Sof-Lex de granulação fina e submetidas posteriormente a um tratamento térmico correspondente a 500 ciclos de 20 segundos cada, nas temperaturas de 5ºC e 55ºC. Imediatamente após a termociclagem, os espécimes tiveram a superfície totalmente coberta por 2 camadas de esmalte de unha, exceto 1mm aquém e além da interface cemento/material em uma das caixas proximais e da interface dos materiais restauradores na caixa proximal oposta, sendo então imersos em solução de azul de metileno à 2%, onde permaneceram durante 24 horas, mantidos à 37ºC. Decorrido este período, os dentes foram incluídos em bases acrílicas apropriadas para serem adaptadas à máquina de corte, obtendo-se cerca de 4 a 5 cortes para cada espécime. Para avaliar o índice de penetração da solução corante nas interfaces das restaurações, optou-se pela análise qualitativa, através da atribuição de escores previamente determinados. Os resultados obtidos foram então organizados e submetidos aos cálculos estatísticos, concluindo-se que: - nenhum material restaurador utilizado foi apto em impedir 100% a penetração da solução corante nas margens cervicais em cemento; - o Dyract-AP e o Vitremer promoveram respectivamente os melhores resultados de selamento marginal, não ocorrendo entre os mesmos diferenças do ponto de vista estatístico, distinguindo-se significantemente em relação aos demais materiais utilizados; - o Bisfil-2B ocupou uma posição intermediária, diferenciando-se estatisticamente dos demais materiais, sendo porém de maneira desfavorável em relação ao Dyract-AP e ao Vitremer e favorável em comparação ao Dispersalloy, Z-100, Dyract e Freedom, os quais apresentaram, nesta ordem, os piores índices de infiltração marginal, não ocorrendo entre os mesmos diferenças estatisticamente significantes; - referindo-se à interface dos materiais restauradores resinosos, a maioria dos espécimes apresentava-se praticamente isenta de infiltração, apresentando-se esta severa na interface amálgama/resina composta. / Marginal leakage is one of the clinical problem associated with posterior resin composite restoration. The aim of this research was to determine the effectiveness of the marginal sealing of different materials applied at the cervical third of class II cavities in association with resin composite. Microleakage at the cement/material interface and between the restorative materials was measured. Eigth-four human non carie premolars were randomly distributed into seven groups as follow: ¨ group 1 - (control) –Scotchbond MP/Z-100; ¨ group 2 - Copalite/Dispersalloy/Scotchbond MP/Z-100; ¨ group 3 - Vitremer/ Scotchbond MP/Z-100; ¨ group 4 - Prime & Bond 2.1/Dyract/Scotchbond MP/Z-100; ¨ group 5 - Prime & Bond 2.1/Dyract-AP/Scotchbond MP/Z-100; ¨ group 6 - Stae/Freedom/Scotchbond MP/composite resin Z-100; ¨ group 7 - One Step/Bisfil-2B/Z-100. Before the teeth were prepared and restored with the various materials, the apexes were sealed with amalgam. After 24 hours the restorations were polished with Sof-Lex discs and thermocycled alternately soaked at 5 oC and 55 oC for 20 seconds for a total of 500 cycles. After thermocycling the specimens were coated with 2 layers of fingernail polish, but the surface sealant did not approximate to the cement/material interface of the preparation closer than 1.0 mm in one of the proximal boxes and between the restorative materials interface in the opposite proximal box. The teeth were immersed in a 2% methylene blue solution for 24 hours at 37 oC. After this period, the teeth were embeded in acrylic bases and sectioned in 4 to 5 different planes parallel to one another in a cutting machine. Microleakage was determined by a qualitative analysis and allowed the following conclusions: ¨ None of the testing materials avoid 100% microleakage at cervical margins; ¨ Dyract-AP and Vitremer showed statistically significant better results for marginal sealing, when compared to the other materials; ¨ Bisfil-2B presented better results than Dispersalloy, Z-100, Dyract and Freedom which showed the worst rates of marginal leakage; ¨ It was not registred dye penetration at the interface materials/resin composite, except for the amalgam/resin composite interface.
329

Avaliação da resistência ao cisalhamento de três sistemas de núcleos intra-radiculares

Anuar Antônio Xible 26 April 2000 (has links)
Foram comparadas as resistências adesivas ao cisalhamento presente entres os componentes de três diferentes sistemas de núcleos intra-radiculares. Foram utilizados pinos de cerâmica à base de dióxido de zircônia ( Cosmopost ), e pinos de titânio ( Tenax ). Os preenchimentos testados foram a resina composta fotopolimerizável ( Tetric Ceram ) e porcelana vítrea fundível ( IPS Empress Post ). Foram confeccionados 30 espécimes divididos em 03 grupos: 10 espécimes de pinos de cerâmica à base de zircônia, aos quais foi fundida porcelana vítrea; 10 espécimes de pinos de cerâmica à base de zircônia e resina composta fotopolimerizável; e 10 espécimes de pinos de titânio e resina composta fotopolimerizável, todos, de acordo com o fabricante. Os espécimes do grupo 1 necessitaram ser ajustados, por desgaste, à base de prova. Todos foram submetidos a uma força de cisalhamento em uma máquina de ensaios universal Kratos, até fratura. A análise estatística, assim como observações macroscópicas permitiu-nos concluir que: 1- A resistência encontrada entre os componentes dos corpos de prova do grupo Pino de Zircônia X Cerâmica IPS Empress Post apresentou resultados estatisticamente não significantes em relação ao grupo em que foi usado Pinos de Titânio X Resina composta. 2- Os resultados dos sistemas do grupo 1 - Pino de Zircônia X Cerâmica IPS Empress Post - e 3 - Pinos de Titânio X Resina Composta demonstraram diferença estatisticamente significante em relação ao grupo 2, em que foi empregado o sistema dos Pinos de Zircônia X Resina Composta. / The purpose of the present study was to evaluate shear bond strength in three different posts and core systems. Thirty standardized cylindrical cores with 4mm height and 6mm diameter were prepared surrounding the posts in a special prefabricated device. They were divided in three groups. Group 1 was composed of 10 zirconia posts ( Cosmopost – Ivoclar ), which were placed in a special device. Cylinders were waxed surrounding them. The patterns were then invested and glass-ceramic ( Empress Cosmo – Ivoclar ) was heat-pressed in a EP500 furnace ( Ivoclar ). Group 2 consisting of 10 zirconia posts ( Cosmopost – Ivoclar ) adapted in the device and composite ( Tetric Ceram – Ivoclar ) was inserted and then light activated. Group 3 consisting of titanium posts ( Tenax – Whaledent ) was adapted in the same device as group 1 and 2. The same composite was inserted and also light activated. Specimens were tested for shear bond strength in a Kratos universal test machine. Results showed no statistical differences between groups 1 and 3 but significant difference between group 2 and the others. According to above results, it was concluded that systems used in groups 1 and 3 are the most reliable in clinical applications.
330

Comparação entre diferentes materiais utilizados como selantes oclusais

Pardi, Vanessa 28 February 2002 (has links)
Orientador: Antonio Carlos Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T02:26:16Z (GMT). No. of bitstreams: 1 Pardi_Vanessa_M.pdf: 3609956 bytes, checksum: a3fcc1a8d3579efd46f079e6d1412ebf (MD5) Previous issue date: 2002 / Resumo: Embora se observe uma diminuição da prevalência da doença cárie, a superfície oclusal permanece tendo a maior incidência, devido, principalmente, à sua morfologia complexa que dificulta a limpeza mecânica e permite o acúmulo de placa dental. A utilização de selantes de fissuras tem tido comprovada efetividade na prevenção da cárie nessa superfície, no entanto, existe uma busca contínua por um material que- apresente- alta retenção à estrutura dental e efeito anticariogênico mesmo com sua perda macroscópica. Assim, esse trabalho composto por quatro artigos tem como objetivos avaliar a retenção e efetividade na proteção da cárie de: 1) um cimento de ionômero convencional e um cimento de ionôrnero modificado por resina após 2 anos de aplicação clínica como selantes; 2) um cimento de ionômero de vidro modificado por resina, uma resina composta de alto escoamento e uma resina modificada por poliácido após 6 e 12 meses de aplicação clínica como selantes; 3) dois materiais ionoméricos utilizados como selantes após 5-anos de aplicação clínica; 4) uma resina modificada por poliácido após 6 anos de aplicação como selante. Os resultados encontrados mostram que os materiais avaliados por períodos superiores à dois anos, apresentaram uma baixa retenção, no entanto, foram efetivos na prevenção da cárie oclusaL Já os materiais avaliados após 6 e 12 meses apresentaram taxa de retenção total satisfatória. Em relação à cárie, os materiais ionoméricos apresentaram-se efetivos na prevenção de lesões cariosas nas fissuras oclusais / Abstract: Although a decrease of cavities prevalence are observed, occlusal surface remains as a major incidence rate, because of its complex morphology that difficult the mechanical cleaning and allows the accumulation of dental plaque. The use of fissure sealant had proved its effectiveness on cavities prevention on this surface, however there is a continue quest for a material that presents high retention rate to enamel and a anticariogenic effect even after its macrocospic loss. This study is composed of four manuscripts, which main goals are to evaluate retention and effectiveness on cavities prevention of:: 1) two íonomer materiais after two years of clinical use; 2) a ionomer glass cement modified by resin, a flowable composite and a resin modified by a polyacid, after a clínical use as a occlusal sealant during six and twelve months, 3) two ionomer cements used as físsure sealant after five years of clinical use; 4) a polyacid modified resin after six years used as fissure sealant. The finding results show that the materiais evaluated for periods longer than two years present a low retentton rate, however they showed effectiveness on occlusal cavity prevention. Materiais evaluated after six and twelve months presented a satisfactory retention rate. Regarding cavities, the ionomeric material showed its effectiveness on occlusal caries prevention / Mestrado / Cariologia / Mestre em Cariologia

Page generated in 0.0394 seconds