• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Módulo elástico e resistência flexural do PEEK e Lava Ultimate em comparação a cerâmica Y-TZP para pinos intrarradiculares

Pereira, Alana de Castro January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:20:11Z (GMT). No. of bitstreams: 1 340527.pdf: 1472978 bytes, checksum: 7791bdcab6f4fcfa19260303587fac42 (MD5) Previous issue date: 2016 / O objetivo deste estudo foi avaliar as propriedades mecânicas do Lava Ultimate e PEEK, e compará-los a cerâmica Y-TZP no que diz respeito ao módulo elástico e resistência flexural. Para isso foram confeccionadas um total de 60 amostras (n=20) em forma de barras e os grupos foram divididos de acordo com o tipo de material: LAVA, PEEK e Y-TZP. Em seguida foram realizados dois ensaios, o primeiro, não-destrutivo, utilizando o equipamento Sonelastic que verifica o módulo elástico pela da técnica de excitação por impulso; e o segundo, destrutivo, que determina a resistência flexural através do teste flexural de três pontos realizado em uma máquina universal de ensaios Instron 4444. Os valores médios de módulo elástico observados foram 2123,50 MPa (Y-TZP), (LAVA) e 1018,50 MPa (PEEK). Os valores médios de resistência flexural foram 820,9 MPa (Y-TZP), 259,2 MPa (LAVA) e 176,9 MPa (PEEK). Os resultados foram submetidos a análise de variância ANOVA e teste paramétrico de TUKEY ao nível de significância p<0.05. O grupo Y-TZP apresentou os maiores valores médios de módulo de elasticidade e resistência flexural, seguido do LAVA e PEEK. Para o módulo elástico, não houveram diferenças estatísticas significativas entre os grupos LAVA e PEEK. Todos os grupos apresentaram diferenças estatísticas no que diz respeito a resistência flexural. Os resultados desta pesquisa podem sugerir mais testes para a avaliação de outras propriedades indicando assim estes materiais como uma alternativa no uso para pinos intrarradiculares.<br> / Abstract : The aim of this study was to evaluate the mechanical properties of Lava Ultimate and PEEK, and compare them to Y-TZP ceramics with respect to the elastic modulus and flexural strength. To this was made a total of 60 samples (n = 20) in the form of bars and the groups they were divided according to the type of material: lava, PEEK and Y-TZP. Then there were two trials, the first non-destructive, using Sonelastic equipment that checks the elastic modulus by the impulse excitation technique; and second, destructive determining the flexural strength by three-point flexural test conducted on a universal testing machine Instron 4444. The average values of elastic modulus were observed 2123.50 MPa (Y-TZP) (LAVA) and 1018.50 MPa (PEEK). The average values of the flexural strength was 820.9 MPa (Y-TZP), 259.2 MPa (LAVA) and 176.9 MPa (PEEK). The results were submitted to ANOVA and Tukey parametric test of significance level of p <0.05. The Y-TZP group showed the highest average values of elastic modulus and flexural strength, followed by LAVA and PEEK. For elastic modulus, there were no statistically significant differences between LAVA and PEEK groups. All groups showed significant differences with respect to flexural strength. These results may suggest more tests to evaluate other properties thus indicating these materials as an alternative use for post.
172

Efeito do sistema restaurador (compósito e sistema adesivo) e termociclagem na interface dente/restauração classe V : avaliação em OCT e MEV / Restorative system (composite and adhesive system) and thermal cycling influencing teeth/class V restoration interface : OCT and MEV evaluated

Sampaio, Camila Sobral, 1989- 22 August 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T09:19:07Z (GMT). No. of bitstreams: 1 Sampaio_CamilaSobral_M.pdf: 4499191 bytes, checksum: e827ca1cd97b2ad41e3b5fdf21d70308 (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a interface dente/restauração classe V realizada com diferentes sistemas adesivos (condicionamento total e auto-condicionante) e compósitos restauradores (baixa contração e convencional), submetidas à termociclagem (TC), por meio de Tomografia por Coerência Óptica (OCT) e infiltração por nitrato de prata em Microscopia Eletrônica de Varredura (MEV). Foram utilizados 90 terceiros molares humanos livres de cárie, onde foram realizados preparos tipo Classe V (0,7 mm/profundidade x 2 mm/diâmetro), com margens localizadas em esmalte e dentina. Os dentes foram distribuídos aleatoriamente em 6 grupos de 15 dentes cada, de acordo com o sistema adesivo e compósito restaurador utilizado: Grupo 1 - Adper Single Bond 2 (SB2) + Aelite LS Posterior (AP); Grupo 2 - SB2 + Venus Diamond (VD); Grupo 3 - SB2 + Filtek Z250 XT (Z250); Grupo 4 - Clearfil SE Bond (CSE) + AP; Grupo 5 - CSE + VD; Grupo 6 - CSE + Z250. Todos os grupos foram avaliados pré e pós TC por OCT (n=10). Após a TC (1000 ciclos entre 5 e 55°C), 5 dentes de cada grupo foram selecionados aleatoriamente para a realização da infiltração por nitrato de prata. Para cada grupo, outros 5 dentes foram preparados e não submetidos à TC, também para esta avaliação. A infiltração por prata foi visualizada em MEV em aumentos de 50x e 1000x, e posteriormente classificados por escores: 0-sem infiltração; 1- infiltração em camada híbrida; 2- infiltração em camada híbrida e túbulos dentinários; e 3- infiltração em camada híbrida, túbulos dentinários e sistema adesivo. Para a análise das imagens geradas por OCT, foi utilizado o programa Image J. As interfaces esmalte e dentina foram analisadas separadamente. Os dados foram submetidos à análise estatística de metodologia de modelos mistos para medidas repetidas (PROC MIXED para medidas repetidas) e teste de Tukey Kramer (p?0,05%). Para interfaces em dentina, observou-se interação significativa entre sistema adesivo e TC; as restaurações com o sistema adesivo CSE, após TC, apresentaram menores porcentagens de fendas na interface dente/restauração, para todos os compósitos, em comparação com o sistema adesivo SB2. Os resultados após a realização da TC demonstraram maiores valores de fendas, quando comparadas às mesmas amostras previamente à sua realização. Em esmalte, não foram observadas fendas na interface dente/restauração, tanto previamente quanto posteriormente à TC, para os sistemas adesivos e compósitos. Foi realizada análise estatística descritiva para a infiltração por nitrato de prata. A análise de infiltração por prata, tanto previamente quanto posteriormente à TC, não mostrou infiltração em esmalte. Com relação à dentina, houve um aumento no percentual de fendas para todos os sistemas adesivos e compósitos restauradores posteriormente à realização de 1000 ciclos térmicos. Pode-se concluir que, dependendo do sistema adesivo utilizado, a TC pode produzir maiores índices de fendas na interface dente/restauração, para todos os compósitos / Abstract: The aim of this study was to evaluate the tooth / class V restoration interface accomplished by different adhesive systems (total and self-etching) and restorative composites (low shrinkage and conventional), submitted to thermal cycling (TC), using Optical Coherence Tomography (OCT) and silver nitrate leakage by Scanning Electronic Microscope (SEM). It was used 90 human caries free third molars, with class V preparations (0.7 mm/ 2 mm x depth/diameter), with margins located in enamel and dentin. The teeth were randomly divided in 6 groups of 15 teeth each, according to the adhesive and composite restorative system used: Group 1- Adper Single Bond 2 (SB2) + Aelite LS Posterior (AP); Group 2- SB2 + Venus Diamond (VD); Group 3- SB2 Filtek Z250 + XT (Z250); Group 4- Clearfil SE Bond (CSE) + AP; Group 5- CSE + VD; Group 6- CSE + Z250. All groups were subjected to pre and post thermal cycling by OCT evaluation (n=10). After TC (1,000 cycles between 5 and 55°C), 5 teeth of each group were randomly selected for the silver nitrate leakage evaluation. For each group, 5 other teeth were prepared and were not subjected to TC, also for this evaluation. The silver nitrate leakage was observed in SEM in 50x and 1,000x magnification and subsequently classified by scores: score 0- without infiltration; 1- infiltration in the hybrid layer; 2- infiltration in the hybrid layer and dentinal tubules; and 3- infiltration in the hybrid layer, dentinal tubules and adhesive. For the analysis of images generated by the OCT, it was used the Image J software. The enamel and dentin interfaces were analyzed separately. Data were submitted to statistical analysis of mixed model methodology for repeated measurements (PROC MIXED for repeated measurements) and the Tukey Kramer Test (p?0.05). For dentin interfaces, it was observed that there was a significant interaction between adhesive and TC; the restorations with CSE adhesive system, after TC, showed smaller percentages of gaps at the dentin / restoration interface, for all composites, comparing to the SB2 adhesive system. With respect to thermal cycling, the results after their achievement showed lower values of interfacial adaptation, when compared the same samples prior to their implementation. In enamel, it was not observed gaps in the interface, both pre and post-TC, for all composite and adhesive systems. Descriptive statistics was used to analyze silver nitrate leakage. For the analysis of silver nitrate leakage, it was observed that there was no infiltration by silver nitrate in enamel both before and after TC. With respect to dentin, there has been an increase in the marginal failure rates for all adhesive systems and restorative composites after 1000 thermal cycles. It can be concluded that, depending on the adhesive system, TC can provide higher percentage of gaps at the tooth/restoration interface, for both studied composites. CSE provided improved interfacial adaptation than SB2 / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
173

Estudo de ligas metalicas alternativas empregadas na odontologia : analise quimica qualitativa e quantitativa, dureza superficial, manchas e oxidação

Stolf, Wolney Luiz, 1937- 03 August 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:41:11Z (GMT). No. of bitstreams: 1 Stolf_WolneyLuiz_LD.pdf: 1856844 bytes, checksum: 4a93a10d660d3a242d80e6c676811661 (MD5) Previous issue date: 1993 / Resumo: Este estudo teve o objetivo de verificar a composição química qualitativa e quantitativa, dureza superficial e resistência a manchas e oxidação de ligas alternativas com baixo teor de ouro (Weissgold), de prata-paládio (Zilberpal), de prata (Zanardo, Superalloy, Spliteraloy, Tanaloy) e de cobre-alumínio (Dura cast MS, Idealloy). Os ensaios da análise química qualitativa e quantitativa foram feitos por espectometria de emissão atômica com plasma induzido de argônio (ICP-AES) modelo 975 ATOMCOMP-JARREL ASH. A dureza superficial Vickers foi verificada num aparelho Durimet (ERNEST LEITZ WETZLAR) de acordo a técnica proposta por RYGE, FOLEY e FAIRHUST59. As manchas e oxidação foram observadas após armazenamen todas amostras por quatro semanas em saliva artificial. As fotos das amostras antes e apôs armazenagem em saliva artificial foram comparadas e a quantidade de manchas e oxidação foram quantifica das e transformadas em números apresentadas em tabelas e gráficos. O autor concluiu que as ligas apresentaram uma composição básica condicente com seu sistema, apresentando peguenas variações em suas percentagens, além da inclusão de um ou outro ele mento químico diferente em sua composição. A dureza superficial para cada tratamento (liga virgem, fundida, refundida com 50% de liga virgem e refundida sem acresci mo de liga virgem) não apresentou uma coerência de resultados entre ligas. As manchas e oxidação também não apresentaram coerência de resultados para cada tratamento entre ligas. Esses resultados de dureza superficial e de manchas e oxidação sugerem que essas ligas alternativas não apresentam homogenidade ou são facilmente influenciáveis pelo processo de fundição / Abstract: The proposal of this study was to verify the chemical composition in quality and quantity, superficial hardness and resistance of stain and oxidation of alternative alloys with low-gold (Weissgolg), ailver-paladium (Zilberpal), silver (Zanardo, Superalloy, Spiteraloy, Tanaloy) and cooper-alluminium (Duracast MS, Idealloy). The chemical anlyse test in quality and quantity were done by Spectrometric of atomic emission with plasma conducible of argon (ICP-AES) model 975 ATOMCOMP-JARREL ASH. Vickers superficial hardness was verifyed in an aparattus Durimet (ERNEST LEITZ WETZIAR) in agree with the tecnigue of RYGE, FOLEY and FAIRHUST59. The stain and oxidation was observed after specimens storage during four weeks in artificial saliva. The pictures of the especimens before and after the storage in artificial saliva were compeared and the amount of stain and oxidation was quantified and transformed in numbers presented in tables and grafics. The autor concluded that the alloys presented a basic composition suitable with its system, with vary in percentage, yonder the inclusion of one or another different chemical element in its composition. The superficial hardness of each treatment (virgin alloy, cast, recast with 50% of virgin alloy and recast without virgin alloy) didn"t present a coherence in the results among the alloys. The stain and oxidation didn"t either present coherence in the results of each treatment among the alloys. These results of superficial hardness and of stain and oxidation suggest that the alternative alloys didn't present homogeneity or they are easily influenced by the cast process / Tese (livre-docencia) - Univer / Materiais Dentarios / Livre-Docente em Odontologia
174

Influencia de fontes de calor de fundição na fusibilidade e dureza de uma liga de Ni-Cr nova refundida acrescida ou não de liga nova

Fernandes, Daniela Rodrigues 24 April 2003 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T16:20:02Z (GMT). No. of bitstreams: 1 Fernandes_DanielaRodrigues_M.pdf: 3687267 bytes, checksum: 9821b159222a8f053512a16a7c73db7e (MD5) Previous issue date: 2003 / Resumo: O objetivo deste trabalho foi verificar a influência da fonte de calor na fusibilidade e dureza de uma liga comercial à base de Ni-Cr (VERA BOND 11) nova, refundida (100%) e nova acrescida de sobras (50%). Para análise da fusibilidade foram confeccionadas 10 amostras para cada condição de liga, com uma tela para peneira de poliéster, com 11 X 11 filamentos de 0,22 mm de espessura, perfazendo uma malha de 100 espaços quadrados fixada bilateralmente por toda a extensão em fios de cera de 2,5 mm, contendo um pino formador do canal de alimentação no vértice. Para análise da dureza foram confeccionadas pastilhas em cera azul regular, com 8,0 mm de diâmetro por 2,0 mm de espessura, unidas a um pino formador do canal de alimentação. Após a obtenção dos padrões, estes foram fixados à base formadora do cadinho, de forma que a distância da base à câmara de reserva fosse 0,5 cm. Uma solução redutora da tensão de superfície foi aplicada sobre o padrão e após a secagem, este foi incluído em revestimento fosfatado - Termocast (Polidental, São Paulo Brasil) manipulado a vácuo, seguindo as instruções do fabricante quanto a proporção e tempo de manipulação. Os anéis foram aquecidos em forno elétrico (EDG) até atingirem a temperatura de 900°C, quando foram preenchidos por aproximadamente 15 gramas de liga fundida pela fonte de calor maçarico oxigênio/acetileno ou indução. A injeção da liga foi realizada por uma máquina centrifuga. Após a obtenção e limpeza dos corpos-de-prova foi realizada a análise de fusibilidade, com o auxílio de um microscópio comparador com aumento de 16 X, considerando o número de espaços preenchidos no molde pela liga. Para análise da dureza superficial Rockwell 30T, os corpos-de-prova foram incluídos em resina acrílica quimicamente ativada, polidos e levados ao aparelho de dureza Testor HTI Super-Panambra, onde foram realizadas as medidas e obtidas as médias. Os resultados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey, em nível de significância de 5%. Quando foram comparadas as fontes de calor com os diferentes tipos de liga houve diferença estatística significativa entre as fontes de calor, na qual o aquecimento por indução demonstrou melhores resultados para fusibilidade. Não houve diferença estatística significativa nos valores médios de dureza quando foi utilizada a fonte de calor maçarico e aquecimento por indução para as ligas virgem e mista, porém o aquecimento por indução demonstrou melhores resultados que o maçarico, diferindo estatisticamente os valores de dureza, quando da utilização da liga refundida / Abstract: The aim of the present study was to verify the influence of the heat source on the castability and hardness of a Ni-Cr-based commercial alloy ¿ VERA BOND 11 - in three different conditions: new (first use), recast, and new mixed with scraps. In order to evaluate castability, 10 specimens were made for each alloy condition, using a polyester sieve with 11x11 filaments, 0.22mm thick, resulting in a screen with 100 square spaces. This screen was fixed to 0.25mm threads along the extension of two sides, and a post was fixed to its vertex. In order to perform hardness analysis, circular specimens made of regular blue wax measuring 8.0 mm in diameter and 2.0 mm thick were connected to the post, forming the sprue. The patterns were then fixed to the casting chamber, so that the distance from the base to the reservoir was 0.5 cm. A surface tension-reducing solution was abundantly applied to the patterns and after drying, the patterns were embedded into a phosphate-bonded investment - Termocast (Polidental, São Paulo, Brazil) manipulated under vacuum pressure, following manufacturer's instructions regarding proportions and manipulation times. Casting rings were placed in an electric oven (Bravac) until the temperature of 900°C was reached, and were then filled with approximately 15 grams of alloy, molten either by an oxigen/acethylen gas torch or by induction as heat sources. Following this procedure, castability analysis was performed. A comparison microscope of 16x magnifying power was used to count the number of spaces which were filled by the alloy. In order to evaluate hardness Rockwell 30T, specimens were embedded in chemically activated acrylic resin and then placed on a Testor HTI Super-Panambra hardness teste r. Hardness values for each specimen were obtained, and the average hardness was calculated. Results were submitted to analysis of variance and averages were compared by Tukey's test at 5% probability. There were statistically significant differences between the heat sources applied to the different types of alloy, with induction presenting the best castability results. There were no statistically significant differences in the average hardness values between torch or induction as the heating source for new and mixed alloys, although induction showed the best results, leading to statistically significant differences in hardness, when recast alloy was used. / Mestrado / Mestre em Materiais Dentários
175

Influencia do tipo de preparo na retenção de coroas totais e restaurações metalicas fundidas, fixadas com cimentos de ionomero de vidro convencional e modificado por resina

Martins, Fabio 17 August 1998 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T23:10:32Z (GMT). No. of bitstreams: 1 Martins_Fabio_D.pdf: 4457611 bytes, checksum: 86f57f3d95c884d43b768399a95e8c73 (MD5) Previous issue date: 1998 / Resumo: Oobjetivo deste estudo foi verificar a resistência à tração de coroas totais e restaurações de classe II MOD, cimentadas em preparos efetuados em 64 dentes molares humanos hígidos, recém-extraídos, e armazenados em soro fisiológico por 3 meses, utilizando cimento de ionômero de vidro convencional Shofu Glaslonomer e modificado por resina Vitremer 3M. Após a profilaxia, as raízes de cada dente foram incluídas em resina acrílica. A coroa foi preparada inicialmente em tomo mecânico e a fmalização do preparo foi feita com ponta diamantada em alta rotação refrigerada à água, até a obtenção de um preparo cônico para coroa total ou um preparo estilizado tipo classe II, para restaurações MOD. Em seguida, as restaurações metálicas foram obtidas com liga à base de Ni-Cr através da técnica de fundição pelo método da cera perdida. Os corpos-de-prova foram divididos em oito grupos de 8 unidades ada, sendo quatro grupos para os preparos de coroa total e quatro para os preparos de restaurações de classe II MOD, ficando metade dos grupos cimentados com cada tipo de cimento ionomérico, com e sem ciclagem térmica. A cimentação foi realizada sob carga estática compressiva de 5 kgf durante 10 minutos e os ensaios de tração numa máquina de ensaio universal Otto Wolpert-Werke (Alemanha), nuína velocidade de 6 mm/min., após 24 horas de armazenagem. Os resultados foram submetidos à análise de variância e teste de Tukey a 5% de probabilidade. Os autores concluíram que o cimento de ionômero de vidro modificado por resina Vitremer-3M obteve os maiores valores de resistência à tração em relação ao cimento de ionômero de vidro convencional Shofu Glaslonomer, em todas as situações estudadas, exceto quando as restaurações MOD sofreram tratamento térmico / Abstract: The object of this study was to verify the resistance to tension strength of total and inlays MOD metalic crowns, cemented to human teeth with glass ionomer Iutins cement Shofu GIaslonomer and resin-modified glass ionomer Iuting cement Vitremer-3M. Sixty-four sound, recently-extracted human molars were used. The dental crown of each tooth was machined initially in a mechanicalIathe until the form adequate for the preparation for a total and inlays MOD crown was obtained, Iather, "the handpiece was used to frnishthe preparation. The total and inlays MOD crowns were obtained by the 10st-waX dental casting method, using a Ni-Cr based alIoy. The prepared teeth, with their respective cast croWllS, were separed into eight groups of 8 teeth each, cemented with the two cements, with and without termical cycle. Analysis of the variations recorded, in reference to the Tukey test, showed that the average - values obtained for the eight groups did show a statistically significant diferences in the comparison of the two rpaterials, and with the two preparation, with and without tennical cyc1e. Analysing the resuIts the autours conc1uded that the resin-modified glass ionomer Iuting cement Vitremer-3M have the most resistence of tension strength in alI cases, except with inlay MOD metalic Ni-Cr crowns with termica) cycle / Doutorado / Materiais Dentarios / Doutor em Ciências
176

Avaliação dos procedimentos de acabamento e polimento sobre a rugosidade superficial de resinas compostas

Ono, Rosana 23 June 1995 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T10:59:33Z (GMT). No. of bitstreams: 1 Ono_Rosana_M.pdf: 4255967 bytes, checksum: beac92cd6b873a75eec9adb61e7fe7f1 (MD5) Previous issue date: 1995 / Resumo: o propósito do presente trabalho foi avaliar "in vitro" a rugosidade superficial dos compósitos Herculite XR V (Sybron/Kerr), Z 100 (3M Co.) e Tetric (Vivadent), submetidos a diferentes procedimentos de acabamento e polimento. Foram confeccionados 24 corpos de prova de cada material, com 8mm de diâmetro por 2mm de espessura; o preenchimento da matriz foi incremental, com exposição individual de 60 segundos, com. fotopolimerizador Visilux 2 (3M). Após o procedimento total de polimerização, os corpos de prova foram removidos da matriz e armazenados, em estUfa, a 37° C e umidade relativa de 100% por 24 horas. Após este período de tempo, cada grupo de amostras foi submetido aos procedimentos de acabamento e polimento com diferentes tipos de materiais abrasivos. Cada procedimento de acabamento e polimento foi realizado por aproximadamente 2 minutos, respectivamente com auxílio do aparelho de alta velocidade de rotação (Turbina- DABI ATLANTE), refrigerados com jatos de água/ar, com movimentos lineares em uma única direção, e contra-ângulo (Micromotor DABI ATLANTE) em baixa velocidade de rotação, à seco. As superficies das amostras foram avaliadas antes e após cada procedimento e a leitura considerada foi a média aritmética entre os picos e vales (Ra), percorrida pelo perfilômetro (Prazis-Rug 3-Argentina), num trecho de 4,8mm. De acordo com os resultados, os procedimentos de acabamento com brocas de 30 lâminas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance + Prisma Gloss produziram índices de rugosidade sem diferença estatisticamente significativa sobre Herculite XRV, Z 100 e Tetric. Os procedimentos de acabamento com pontas diamantadas F e FF e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel apresentaram índices de rugosidade com diferença estatisticamente significativa quando comparados aos polimentos com discos Sof-Lex (fino e extrafino) ou Enhance + Prisma Gloss, sobre I Herculite XR VeZ 100. Observou-se também que os procedimentos de acabamento com pontas diamantadas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance não apresentaram diferenças estatisticamente significativas sobre o compósito Tetric / Abstract: The purpose of this study was to evaluate the in vitro surface roughness of Herculite XR V, Z 100 and T etric composite samples, subjected to different finishing and polishing procedures. A set of twenty-four 8mm diameter, 2mm thick samples was prepared for each studied material, using the incremental technique for mold filling. A sixty-second exposure to visible light was necessary to set the samples. The activating unit used was Visilux 2 (3M). After setting, the samples were stored in an oven, at 37°C and 100% relative humidity for 24 hours. Afterwards, each group of samples was subjected to the finishing and polishing procedures with different types of materials and abrasives. E,ach finishing and polishing procedure lasted approximatel y 2 minutes. The finishing procedure was carried out with the aid of an air-water spray, high speed handpiece, moved straight on a one and on1y direction. An air-cooled, low-speed handpiece was used for the polishing procedures. The surfaces of the samples were evaluated before and after each procedure and the reading that was ~sed was the arithmetic mean value between the peaks and valleys scanned by the surface t According to t he results, the finishing procedures with 30 blade burs, and polishing with Viking (grey and green) silicone abrasives + gel, Sof Lex (fine and extra-fine) discs and Enhance + Prisma Gloss, have produced roughness indexes without significant statistical differenceS for Herculite XRV, Z 100 and Tetric. The finishing procedures with F and FF diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel showed roughness indexes with significant statistical differences when compared to the polishing procedures with Sof- Lex (fine and extra-fine) disks or Enhance + Prisma Gloss, for Herculite XRV and Z 100. It has also been observed that the finishing procedures with diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel, I Sof-Lex (fine and extra-fine) disks and Enhance + Prisma Gloss didn't show significant statistical differences for Tetric composite / Mestrado / Materiais Dentarios / Mestre em Ciências
177

Avaliação da liberação de fluor de materiais restauradores em função dos meios de imersão

Carvalho, Adriana Silva de 20 June 1995 (has links)
Orientador: Jaime Aparecido Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T14:18:36Z (GMT). No. of bitstreams: 1 Carvalho_AdrianaSilvade_M.pdf: 3083458 bytes, checksum: 4369d5e8175e32b0af665b44c634a192 (MD5) Previous issue date: 1995 / Resumo: A maior parte dos estudos realizados a respeito da avaliação da liberação de flúor de materiais restauradores tem sido feita em água destilada ou saliva artificial, que não simulam a dinâmica do meio bucal, ocorrendo até inversão de resultados, quando comparados com os resultados in vivo. Por isso resolvemos avaliar à liberação de flúor de diferentes cimentos de ionômero de vidro e resinas compostas em função do tempo de imersão em diferentes soluções, considerando a dinâmica do processo de cárie (des-remineralização). Para isso utilizamos os seguintes materiais restauradores: Chelon-fil (ESPE), Vitremer (3M), Variglas's (Dentsply), Dyract (Dentsply) e Tetric (Vivadent). Confeccionamos 18 amostras cilíndricas (área=I,65 cm2) de cada material, essas amostras foram imersas individualmente em 2 ml de cada solução estudada (6 amostras para cada solução). As soluções utilizadas foram água desionizada, saliva artificial e ciclagens de pH, deixando as amostras 6h na solução desmineralizante (Ca e P 2,0 mM, pH 4,3) e depois por 18h na solução remineralizante (Ca 1,5 mM, P 0,9 mM, pH 7,0). Essas soluções foram trocadas diariamente e armazenadas durante 15 dias. A liberação de flúor foi determinada após adição de volume igual de tampão TISAB II às soluções. Para a análise da concentração de flúor foi utilizado um eletrodo específico para flúor Orion 96-09, acoplado a um analisador de íons Orion EA-940. A liberação de flúor (média e desvio padrão) em Jlg F/cm2 foi: em água desionizada- CHE=7,6170:!:0,7619 a, VIT=5,9095:!:0,7939 b, VAR=2,7154:!:0,2463 c, DYR=I,4973:!:0,1699 d, TET=0,1361:!:0,0162 e; em saliva artificial- VIT=3, I 330:!:0,3.60 I a, CHE=I,2605:!:0,0842 b, DYR=I,2001:!:0,0519 b, V AR=0,7997:!:0,0981 c, TET=0,0741:!:0,0038 d; e nas ciclagens de pH- VIT=12,2727:!:1,1577 a, CHE=8,3472:!:0,5132 b, DYR=7,8196:!:0,6534 c, VAR=6,1725:!:0,2447 d, TET=0,2777:!:0,0234 e. Médias seguidas por letras distintas diferem entre si ao nível de significância de 5%. Os dados sugerem que a comparação de liberação de flúor de materiais dentários pode mudar quando os meios de imersão são considerados / Abstract: Most of data reported on release of f1uoride from dental materiaIs cements are based upon measurements made in de-ionized water and artificial saliva, which do not simulate the dinamic of caries development. So, the purpose of this study was to determine the levels of '" f1uoride release from differents glass ionomer cements and composite in function of the time and different storage solutions, considering the dinamic of caries process (pH-cycling). The materiaIs used were: Chelon Fil-ESPE (CHE), Vitremer-3M (VIT), Variglass-DENTSPL Y (V AR), DyractDENTSPL Y (DYR) and Tetric-VIV ADENT (TET). Eighteen cilindrical samples (area=1.65 cm2) of each material were prepared; each sample was then suspended individually in a plastic tube containing 2 ml of each studied solution (6 samples for each solution). The studied solutions were deionized water, artificial saliva and pH cycling, remaining 6h in desmineralization solution (Ca and P 2.0 mM, pH 4.3) and then for a period of 18h in remineralization solution (Ca 1.5mM, P 0.9mM, pH 7.0). AlI solutions were changed daily during 15 days. Fluoride releasing was determined after buffering the solution with equal volume of TISAB. For the f1uoride analysis it was used a f1uoride electrode, Orion 96-09, and an ionalyser Orion EA 940. The f1uoride released (mean :t standard error) in JlgF/cm2 were: in de ionized CHE=7 . 617 0:t0. 7 319 VIT=5.9095:t0.7939 water V AR=2.7154:t0.2463 c, DYR=I.4973:tO.l699 d, TET=0.136l:t:0.0162 e; in artificial saliva- VIT=3.1330:t0.3601 a, CHE=I,2605:t0.0842 b, DYR=1.2001:t0.0519 b, V AR=0.7997:t0.0981 c, T=0,0741:t0.0038 d; and in pH cycling- VIT=12.2727:t1.1577 a, CHE=8.3472:t0.5132 b, DYR=7.8196:t0.6534 c, VAR=6.172S:t0.2447 d, TET=0.2777:t0.0234 e. Means followed by different letters were significant (5%).The data suggest that the comparison of fluoride releasing from dental materiais can change when the media are considered. / Mestrado / Materiais Dentarios / Mestre em Ciências
178

Estudo comparativo da forca de tração desenvolvida pelas cadeias elastomericas nacionais e importadas

Spiegel, Alfredo A 13 July 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia / Made available in DSpace on 2018-07-13T23:08:09Z (GMT). No. of bitstreams: 1 Spiegel_AlfredoA_D.pdf: 1644785 bytes, checksum: 4378581566ca76019e1746744942593b (MD5) Previous issue date: 1990 / Resumo: Este trabalho teve como objetivo comparar "in vitro" as forças de tração exercidas pelas cadeias elastoméricas em função do tempo de distensão. Foram usados 4 tipos comerciais de cadeias elastoméricas, dois de fabricação nacional (Tecnident, tipos Cristal e Cinza) e dois de fabricação estrangeira ...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: The objective of this work was to compare "in vitro" the traction force produced by the elastomeric chains considering the extension time. Four commercial types of elastomeric chains were used, two Brazilian (Tecnident, types Clear and Gray) and two foreign ones ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Ortodontia / Mestre em Ciências
179

Contribuição ao estudo da solubilidade e desintegração dos cimentos de silicato em soluções antissepticas

Sampaio, Teresa de Jesus Sousa 15 July 2018 (has links)
Orientador: Luiz Antonio Ruknke / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-15T15:18:45Z (GMT). No. of bitstreams: 1 Sampaio_TeresadeJesusSousa_M.pdf: 1450218 bytes, checksum: e46b72e00131866b723b445769656c66 (MD5) Previous issue date: 1984 / Resumo: o objetivo deste trabalho foi verificar a inf1uência exercida pelas soluções antissipticas da cavidade oral sobre a solubilidade e desintegração do cimento de silicato Porcelana Melhorada da S.S.White comparando-a com a desintegração em água destilada que é o meio solvente recomendado pela especificação n. 9 da American Dental Association. Em virtude da dificuldade de separar o resíduo seco do próprio meio daquele deixado pelos corpos de prova do cimento, a desintegração nas soluções :antissépticas foi calculada a partir da porcentagem de fosfato liberado nos referidos meios. Os resultados analisados permitiram concluir que: 1) a desintegração foi maior no grupo constituído pelas soluções antissépticas "Flororal" e "Ma1vatricin", seguidas em ordem decrescente por ãgua destilada, "Malvona" e finalmente pelo grupo constituído pelas soluções de "Anapyon" e "Cepacol"; 2) a porcentagem de desintegração em água destilada, apresentada pelo cimento utilizado, está de acordo com o índice estabelecido pela especificação n. 9 da American Dental Association / Abstract: The present study was carried out to evaluate the influence of antisseptical solutions upon the solubility and disintegration of one brand of silicate cement, in comparison with the amount of disintegration in distilled water, according to American Dental Association Specification n. 9. Due to the fact that the application of the A.D.A. method may distort the results and cause difficult in interpretation, the disintegration was calculated indirectly from the phosphate percentage evaluated from the specimens. The results have shown that: 1) the disintegration level was bigger in the media M3 (Flogoral) and M4 (Malvatricin) followed by Ml (water distilled), M2 (Malvona) and finally by the group that presented the lowest disintegration, M5 (Anapyon) and M6 (Cepacol); 2) the disintegration percentage presented by the brand of silicate cement is in accordance with the level established by American Dental Association Specification n. 9 / Mestrado / Materiais Dentarios / Mestre em Odontologia
180

Influencia de metodos endurecedores sobre algumas propriedades fisicas e na formação cristalina dos gessos tipo IV

Pipolo, Julita de Campos 23 December 1992 (has links)
Orientador: Luiz Antonio Ruhnke / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-17T08:53:10Z (GMT). No. of bitstreams: 1 Pipolo_JulitadeCampos_M.pdf: 2585403 bytes, checksum: bda2967414ed3d8090aa1c493cbc2423 (MD5) Previous issue date: 1992 / Resumo: Os testes de alteração dimensional de presa, resistencia a abrasão, dureza superficial e resistencia a compressão, e os aspectos cristalinos dos gessos Tipo IV (Vel-Mix, Suprastone, Durone e Herostone) foram verificados sob a influencia da solução endurecedora e imersão em oleo mineral ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: Four gypsum brands Type IV (Vel-Mix, Suprastone, Durone, and Herostone) were submitted to the setting methods hardness solution and mineral oil imersion to determine the setting expantion, abrasion resistance, surface hardness and compressive strength, and crystalin aspects ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Materiais Dentarios / Mestre em Ciências

Page generated in 0.0896 seconds