• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 238
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 239
  • 123
  • 114
  • 74
  • 58
  • 51
  • 45
  • 41
  • 41
  • 40
  • 38
  • 36
  • 36
  • 35
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Tratamentos alternativos para a substituição de restaurações defeituosas: avaliação após 12 anos / Alternative treatments for replacement of defective restorations: evaluation after 12 years

Estay Larenas, Juan Nelson [UNESP] 16 November 2016 (has links)
Submitted by JUAN NELSON ESTAY LARENAS null (zamuray@gmail.com) on 2017-05-03T21:00:51Z No. of bitstreams: 1 Tese final Juan Nelson 03052017.pdf: 1890078 bytes, checksum: 55ef58f0601ef746920e86e0b6ff5998 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-05T13:11:49Z (GMT) No. of bitstreams: 1 estaylarenas_jn_dr_arafo.pdf: 1890078 bytes, checksum: 55ef58f0601ef746920e86e0b6ff5998 (MD5) / Made available in DSpace on 2017-05-05T13:11:49Z (GMT). No. of bitstreams: 1 estaylarenas_jn_dr_arafo.pdf: 1890078 bytes, checksum: 55ef58f0601ef746920e86e0b6ff5998 (MD5) Previous issue date: 2016-11-16 / O objetivo deste trabalho foi determinar o efeito da reparação, selamento marginal e recondicionado sobre a longevidade de restaurações posteriores de resina composta e amálgama segundo Critério USPHS/Ryge. 34 pacientes de 18 a 80 anos (média de 26,5 anos), formado por mulheres (58%) e do sexo masculino (42%), que tiveram um total de 106 restaurações de resina e 194 de amálgama foram recrutados na Clinica de Dentística da Universidade de Chile. As restaurações apresentavam defeitos localizados marginais ou cáries secundárias que foram avaliadas e classificado como Bravo ou Charlie acordo com os critérios modificados United States Public Health Service (USPHS). As restaurações foram distribuidos em 4 grupos: 1. Reparação (n=35), 2. Selamento (n=48), 3. Substituição (n=43), 4. Recondicionamento (n=85 ) e 5. Controle sem tratamento (n= 89). As restaurações foram avaliadas pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (Kappa >0.8) após 1, 2, 3, 4, 5, 10 e 12 anos de observação. Resultados: Ao comparar entre os grupos Reparação e Substituição após 12 anos, Não houve diferenças estatisticamente significativas em sobrevivencia nem estado clínico. Ao comparar entre os grupos Selamento e Sem tratamento após 12 anos. Não houve diferenças estatisticamente significativas em adaptação marginal, sensibilidade ou cáries secundárias. Ao comparar entre os grupos Recondicionamento e Sem tratamento, houve diferenças estatisticamente significativas para adaptação marginal em restaurações de resina composta e Anatomia em restaurações de amálgama. / The aim of this study was to determine the effect of the repair and sealing ability on the longevity of composite resin and amalgam using USPHS / Ryge clinical criteria. 34 patients with 18-80 years (mean 26.5 years), formed by women (58%) and male (42%), which had a total of 106 resin composite restorations and 194 amalgam restorations, were recruited in Clinic Dentistry at the University of Chile. The restorations had marginal localized defects or secondary caries rated Bravo and Charlie or according to the modified criteria United States Public Health Service (USPHS). The restorations were divided into 4 groups: 1. Reparation (n = 35), 2. Sealing (n = 48), 3. Replacement (n = 43), 4. Refurbishing (n=85) and 5. No treatment (n = 89). The restorations were evaluated by USPHS / Ryge criteria by two trained and calibrated examiners (kappa> 0.8) after 1, 2, 3, 4, 5, 10 and 12 years of observation. Results: When comparing between repair and replacement groups after 12 years, there was no statistically significant differences in survival or clinical status. When comparing between the groups Sealing and No treatment after 12 years. There were no statistically significant differences in adaptation marginal, sensitivity or secondary caries. When comparing between the groups Refurbishing and No Treatment, there was statistically significant differences for Marginal Adaptation in resin composite restorations and Anatomy in Amalgam restorations.
132

Análise comparativa da infiltração marginal em restaurações de classe II em resina composta com diferentes técnicas de inserção /

Macedo, Ricardo Prates. January 2004 (has links)
Orientador: José Roberto Cury Saad / Banca: Adair Luís Stefanello Busato / Banca: Alcebíades Nunes Barbosa / Banca: Maria Salete Machado Cândido / Banca: Welingtom Dinelli / Resumo: Neste trabalho, estudou-se a influência de quatro diferentes técnicas de inserção (Incremental, Única, Beta-quartzo e Pré-polimerizada) da resina composta fotoativada em dois tamanhos de cavidades classe II, no vedamento marginal, através de testes de infiltração de um agente corante. As cavidades foram preparadas em dentes molares humanos extraídos, com a parede cervical localizada em cemento. Os materiais (adesivo dentinário e resina composta) foram de uma mesma marca comercial. Realizadas as restaurações, os dentes foram submetidos à termociclagen (5o C e 55o C, durante 500 ciclo) e depois de adequadamente impermeabilizados, foram imersos em solução corante Rodamina a 5% por uma semana. Em seguida, os dentes foram cortados e avaliados, quanto à microinfiltração na interface parede gengival e material restaurador, por dois examinadores, segundo um critério pré-estabelecido (graus de 0 a 3). Após a análise dos resultados, foi possível concluir que: a técnica incremental em esmalte (Grupo 1B e 2B) foi a que apresentou os menores níveis de infiltração marginal, logo a que produziu o melhor vedamento marginal. A técnica incremental em cemento (Grupo 1C) apresentou resultados intermediários, não sendo estatisticamente diferente dos grupos 1B e 2B. A técnica com inserção de Beta Quartz Inserts (Grupos 1E e 2E), e técnica de inserção de pérolas pré-polimerizadas de resina (Grupos 1F e 2F) foram as menos efetivas em impedir a infiltração marginal. A confecção de um bisel chanfrado parece desempenhar importante papel na qualidade das margens das restaurações. / Abstract: This study had the purpose of evaluating the influence of four different techniques of insertion of composite resin (Incremental, Single, Beta-quartz inserts nd Pre-cured) in two sizes of Class II cavities, regarding marginal sealing when submitted to leakage tests using a dying agent. Cavities were prepared in extracted human molars, presenting the cervical wall in the cementum area. Materials used (adhesive and composite resin) were from the same manufacturer. After the restorations were done, teeth were subjected to thermo cycling (5º C e 55º C, for 500 cycles), and then carefully coated with nail polish before submersed in a 5% Rodamine, for the period of one week. Teeth were then sectioned and evaluated to microleakage, at the interface gingival wall and restorative material, by two evaluators following pre-determined criteria (from 0 to 3). After analyzing the results it was possible to conclude that: incremental technique in enamel (Group 1B e 2B) presented the lowest levels of marginal leakage or the best marginal sealing. The incremental technique for the cementum group (Group 1C) presented intermediary results, not statistically different from group 1B e group 2B. The techniques using Beta Quartz Inserts (Groups 1E e 2E), and pre-cured pellets of resin (Groups 1F e 2F) were the least effectives in preventing the marginal leakage. The preparation of a chamfered bevel seemed to play an important role in the quality of the margins of the restorations. / Doutor
133

Avaliação clínica de restaurações indiretas em resina composta cimentadas com material resinoso convencional e autoadesivo

Marcondes, Maurem January 2014 (has links)
Made available in DSpace on 2014-06-04T17:46:30Z (GMT). No. of bitstreams: 1 000458471-Texto+Completo-0.pdf: 1434696 bytes, checksum: 1b82056bbee62d1935b0803e571f0c64 (MD5) Previous issue date: 2014 / The aim of this study was to clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cement, during a 12-month period. Twenty-four composite resin restorations were performed through indirect technique and cemented with two resin cements: a conventional (RelyX ARC) and a self-adhesive (RelyX U100). Two independent evaluators analyzed the restorations using the criteria of the USPHS (United States Public Health Service) modified after two weeks, six months and 12 months. For the analysis of data from USPHS, between the cements at the same time, it was used the Wilcoxon statistical test and for evaluation at different times, it was used the Mann-Whiney test, at significance level of 5 %. The Fisher exact test was used to assess the occurrence of absolute failures. No statistically significant differences were found between groups in the same period and between groups at different times, one statistical difference was found only for the criteria color match. We conclude that indirect composite resin restorations cemented with self-adhesive resin cement showed a similar performance of restorations cemented with conventional resin cement after a year of analysis. / O objetivo deste estudo foi avaliar clinicamente o desempenho de restaurações indiretas de resina composta cimentadas com cimento resinoso convencional e autoadesivo no período de 12 meses. Foram realizadas 24 restaurações em resina composta (Filtek Supreme XT), executadas pela técnica indireta e cimentadas com dois cimentos resinosos: um convencional (RelyX ARC) e um autoadesivo (RelyX U100). Dois avaliadores independentes analisaram as restaurações através dos critérios do USPHS (United States Public Health Service) modificado após duas semanas, seis meses e 12 meses. Para a análise dos dados do USPHS, entre os cimentos no mesmo tempo, foi utilizado o teste estatístico de Wilcoxon e, para avaliação nos diferentes tempos, o Mann-Whiney ao nível de significância de 5%. O teste exato de Fisher foi usado para avaliar a ocorrência de falhas absolutas. Não foram encontradas diferenças estatisticamente significativas entre os grupos no mesmo período e entre os grupos nos diferentes tempos, havendo diferença estatística apenas para o critério combinação de cor. Pode-se concluir que restaurações de resina composta indireta cimentadas com cimento resinoso autoadesivo tiveram um desempenho similar às cimentadas com cimento resinoso convencional após um ano de avaliação.
134

Avaliação in vitro da rugosidade superficial de resinas compostas após escovação simulada com diferentes dentifrícios

Monteiro, Bruna January 2014 (has links)
Made available in DSpace on 2014-08-12T02:02:42Z (GMT). No. of bitstreams: 1 000460167-Texto+Completo-0.pdf: 3148675 bytes, checksum: 0fca29414ee88deb42284c417ac20415 (MD5) Previous issue date: 2014 / Aim: Evaluate, in vitro, the surface roughness of two composite resins submitted to a simulated wear test with three different dentifrices, applying simulated periods of six months, one year and two years of tooth brushing. Materials and Methods: Thirty-six samples of Z350XT and 36 samples of Empress Direct were built and randomly divided into three groups (n=12) according to the dentifrice used (Colgate Total 12 Clean Mint [CT12] (control), Colgate Sensitive Pro-Alívio [CS], Oral B Pro-saúde Whitening [OBW]). The samples were submitted to 5,000, 10,000 or 20,000 cycles of simulated tooth brushing. After each simulated period, the surface roughness of the samples was measured using a roughness tester. Results: According to three-way ANOVA, dentifrice (p=0. 044) and period (p=0. 000) were significant. There was no significance for the composite resin factor (p=0. 381) and for the interaction (p>0. 05). CT12 presented the lower surface roughness (0. 269 μm), not differing statistically from CS (0. 300 μm). The highest surface roughness was obtained for OBW (0. 390 μm), not differing statistically from CS. The higher value was obtained after 20,000 cycles (0. 584 μm) of simulated tooth brushing, differing statistically from the other two periods. Conclusions: Z350 XT and Empress Direct presented similar surface roughness after all cycles of simulated tooth brushing. The surface roughness of the composites increased with brushing time. The whitening toothpaste OBW caused higher surface roughness in both composite resins. / Objetivo: Avaliar, in vitro, a rugosidade superficial de duas resinas compostas submetidas à escovação simulada com três diferentes dentifrícios, em períodos de seis meses, um ano e dois anos. Materiais e Métodos: Foram confeccionadas 36 amostras da resina composta Z350 XT e 36 da resina Empress Direct, sendo divididas aleatoriamente em três grupos de 12 (n=12), conforme o dentifrício utilizado (Colgate Total 12 Clean Mint [CT12] (controle), Colgate Sensitive Pro-Alívio [CS], Oral B Pro-Saúde Whitening [OBW]). As amostras foram submetidas a 5. 000, 10. 000 e 20. 000 ciclos de escovação. Após cada período simulado, as amostras de resinas compostas tiveram a rugosidade de superfície mensurada por um rugosímetro. Resultados: Segundo a ANOVA de três fatores, os fatores dentifrício (p=0,044) e tempo (p=0,000) foram significativos. Não houve significância para o fator resina composta (p=0,381) e para a interação entre os fatores (p>0,05). O dentifrício CT12 apresentou a menor média de rugosidade superficial (0,269 μm), não diferindo estatisticamente do dentifrício CS (0,300 μm). A maior média de rugosidade superficial foi obtida com o dentifrício OBW (0,390 μm), não diferindo estatisticamente do CS. A maior média de rugosidade superficial foi obtida após 20. 000 ciclos de escovação (0,584 μm), diferindo estatisticamente dos outros tempos. Conclusões: Z350 XT e Empress Direct apresentaram rugosidade superficial semelhante após todos os ciclos de escovação. A rugosidade superficial das resinas compostas aumentou com o tempo de escovação. O dentifrício clareador OBW causou maior rugosidade de superfície em ambas as resinas compostas.
135

Influência de diferentes procedimentos restauradores na resistência á fratura de dentes com cavidade classe IV submetidos ao clareamento dental interno /

Roberto, Andiara Ribeiro. January 2012 (has links)
Orientador: José Roberto Cury Saad / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Banca: Marcos Porto de Arruda Filho / Banca: Jacy Ribeiro de Carvalho Junior / Resumo: Este estudo teve o objetivo de investigar a influência de diferentes procedimentos restauradores diretos com resina composta e pinos de fibra de vidro, na resistência à fratura de dentes com cavidades Classe IV, tratados endodonticamente e submetidos ao clareamento interno. Quarenta (n=40) incisivos laterais superiores humanos hígidos foram utilizados. Todos os dentes, com exceção do Grupo controle, foram submetidos ao tratamento endodôntico e então divididos em 5 Grupos (n=8): GI: Dentes hígidos; GII: Dentes tratados endodonticamente + resina composta (RC); GIII: Dentes tratados endodonticamente + clareamento com peróxido de hidrogênio (PH) a 35% + RC; GIV: Dentes tratados endodonticamente + Clareamento com PH a 35% + pino de fibra de vidro (Everstick/StichTeck) + RC; GV: Dentes tratados endodonticamente + Clareamento PH a 35% + RC e pino de fibra de vidro (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA);. Os dentes tratados endodônticamente receberam cortes na coroa simulando uma classe IV e posteriormente restaurações de resina composta. O sistema LED-LASER Whitening Lase Light Plus (DMC Equipamentos Ltda, São Carlos, SP, Brasil) foi utilizado para ativação do agente clareador. Após o processo de clareamento, a restauração provisória e o tampão cervical dos dentes submetidos ao clareamento foram removidos para que cada Grupo fosse submetido ao procedimento restaurador. Após a confecção das restaurações as mesmas foram submetidas ao teste de resistência a fratura, em máquina de ensaios (EMIC). A Análise de Variância apontou efeito significativo de Grupos sobre a resistência (p=0,041). O teste de Tukey foi aplicado nas comparações múltiplas das médias de resistência, identificando somente a média de GIII (dentes tratados endodonticamente +clareamento com PH... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to investigate the influence of restorative procedures on fracture resistance of teeth with Class IV cavities endodontically treated and submitted to internal bleaching with light source acceleration using LED-LASER system. Forty (n = 40) lateral incisors and healthy humans were used. All teeth, except for the control Group, were submitted to endodontic treatment and then divided into 5 Groups (n = 8): GI: healthy teeth, GII: endodontically treated teeth + composite, GIII: Teeth whitening endodontically treated with PH 35% + composite, GIV: Teeth whitening endodontically treated with PH 35% glass fiber post (Everstick / StichTeck) + composite, GV: Teeth whitening endodontically treated PH 35% + composite fiber and glass post (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA). The crow of endodontically treated tooth was cut simulating a Class IV. The system LED LASER-Light Plus Whitening Lase (DMC Equipment Ltda, São Carlos, SP, Brazil) was used to activate the bleaching agent. After the whitening process, the buffer cervical and the temporary restoration of teeth submitted to bleaching have been removed so that each Group was subjected to the restorative procedure. After restorations the specimens were subjected to the same fracture toughness test, in a testing machine (EMIC). Analysis of Variance (ANOVA) showed significant effect on the resistance Group (p = 0.041). The Tukey test was applied in multiple comparisons for resistance means values, identifying only the mean of GIII (endodontically treated teeth bleaching with PH 35% + composite) significantly lower than GI (healthy teeth) (p = .026). It was concluded that teeth endodonticamentes treated with cavity class IV, subjected to internal dental bleaching with PH 35% and only restored with RC, have lower fracture toughness when compared to... (Complete abstract click electronic access below) / Doutor
136

Avaliação difratográfica da microestrutura de três resinas compostas submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio / Difractiography evaluation of three dental composites subjected to a bleaching agent-based hydrogen peroxide

Rodrigo Rocha Maia 26 March 2008 (has links)
A odontologia moderna utiliza métodos e técnicas ultraconservadores no intuito de corrigir os diversos tipos de alterações cromáticas observadas clinicamente. Os meios empregados baseiam-se na utilização de substâncias químicas à base de peróxidos presentes em diversas concentrações. O presente estudo objetivou avaliar a microestrutura de três resinas compostas fotossensíveis submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio a 35% (Whiteness HP Maxx - fabricante: FGM), ativado por uma fonte híbrida de energia luminosa (Aparelho de Laser-Led Whitening Lase, fabricante: DMC). Para isso, foram confeccionados 30 corpos de prova (CDP) 10 para cada grupo, no formato de discos, com 13 mm de diâmetro e 2,0 mm de espessura em uma matriz de teflon e aço inox, fotoativados por um aparelho de luz halógena convencional (Optilux 401 - Demetron/UR) por 40 segundos com densidade de potência média igual a 450 mW/cm2. Os grupos foram dispostos da seguinte forma: Grupo 1 - resina microparticulada (Durafill VS - fabricante: Heraeus Kulzer); Grupo 2 - resina micro-híbrida (Esthet-X - fabricante: Dentsply); e Grupo 3 resina nanoparticulada (Filtek Supreme XT fabricante: 3M ESPE). Todos os materiais restauradores utilizados eram da cor A2. Após serem submetidos à sequência de acabamento e polimento os CDP foram armazenados por sete dias em saliva artificial, limpos em ultra-som, envelhecidos artificialmente de acordo com a norma ASTM G 154. Os CDP dos três grupos foram aleatoriamente divididos em 2 subgrupos (ST sem tratamento e CT com tratamento) e finalmente submetidos aos experimentos. Os CDP dos subgrupos 1-ST, 2- ST e 3-ST foram triturados (SPEX SamplePrep 8000-series, marca: Mixer/Mills) seguido pela verificação dos materiais por meio de um espectrômetro (marca/modelo: Shimadzu EDX 720) para certificação da ausência de elementos pertencentes ao meio de moagem e por fim foram levados a um difrator de raios-X (marca / modelo: Philips -PW 3040 -X'Celerator- 40kV; 30mA; (λ): CuKα; 0,6; 0,2mm; 0,05 (2θ); 2s; 10-90 (2θ). Em seguida os CDP dos subgrupos 1-CT, 2- CT e 3-CT foram tratados com o peróxido de hidrogênio de acordo com o protocolo do fabricante para a fonte híbrida luminosa de energia selecionada, totalizando 9 aplicações de 10 minutos, onde eram respeitados os tempos de 3 minutos de ativação por 20 segundos de descanso, finalizando 10 minutos em cada aplicação. Mediante a este tratamento, os CDP dos subgrupos CT eram verificados e avaliados pelo mesmo método descrito anteriormente. Após interpretação gráfica, análise comparativa por meio do processamento digital das imagens no programa KS400 3.0 (Carl Zeiss Vision) e análise de concordância por cinco avaliadores calibrados utilizando um escore, pôde-se concluir que houve degradação estrutural e que as estruturas cristalinas das resinas estudadas foram afetadas de forma distinta quando tratadas pelo peróxido de hidrogênio; onde observou-se que: Grupo 1 > Grupo 3 > Grupo 2. Foi sugerido a realização de novos estudos, relacionados à interação do peróxido de hidrogênio às resinas compostas. / Currently, to correct dental chromatic alterations, the modern dentistry science takes advantage of ultraconservative's techniques and methods. Chemical substances, in particular peroxides are used in various concentrations. The purpose of this study was to evaluate the microstructure of 3 composites resin submitted the applies of a whitening gel - hydrogen peroxide 35% (Whiteness HP Maxx, FGM) activated by a hybrid energy light (Laser-Led, Whitening Lase, DMC). Thirty composite discs (13 mm diameter x 2,0 mm thickness) were made in a teflon custom matrix and assigned to the following groups: Group 1, microfill resin (Durafill VS, Heraeus-Kulzer); Group 2, micro hybrid resin (Esthet-X, Dentsply) and Group 3, nanofill resin (Filtek Supreme XT, 3M ESPE). Samples were light cured with an Optilux 401 (Demetron/UR) for 40s by irradiation powers about 450 mW/cm2. All samples were prepared using shade A2, followed by finishing and polishing procedures. Then, samples were stored in artificial saliva for seven days, ultra-sonicated and submitted an artificial aged (ASTM G 154). After that, each group was randomly divided in two sub-groups: ST Without treatment and CT- With treatment. The ST samples of groups 1, 2 and 3 were triturate using a grinder (SPEX SamplePrep 8000-series, Mixer/Mills), and then the materials were evaluated with a spectroscopy microscope (Shimadzu EDX 720) to verify the absence of milling particles, and a X-ray diffraction patterns were recorded using Philips - PW 3040 -X'Celerator- 40kV; 30mA; (λ): CuKα; 0,6; 0,2mm; 0,05 (2θ); 2s; 10-90 (2θ).The CT samples of group 1, 2 and 3 were treated with hydrogen peroxide following the manufacturer protocols 9 sequential 10 minutes applications/time, totaling 90 minutes. Triturated and evaluated using the same method described above. Comparative analysis by means of image processing software KS400 3.0 (Carl Zeiss Vision), graphic interpretation and agreement analysis by five valuators calibrated using a score of the results shown degree of crystallinity of the tested composites changed by bleaching treatment. After a comparative analysis, Group 1 demonstrated more degradation followed by group 3 and group 2. New studies are necessary to define the exact interaction between composite resin and hydrogen peroxides.
137

Resistência de união à microtração de dentina pré-hibridizada: efeito dos métodos de tratamento de superfície e da temporização

Dillenburg, Álvaro Luis Kroeff January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000385863-0.pdf: 11730392 bytes, checksum: be18f24f5772871dae60f25e74a3ef0b (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the influence of different surface treatments to dentin with pre-cured adhesive layer when the immediate dentin sealing technique (IDS) was applied in different storage time with provisional cement on microtensile bond strength of two adhesive systems, classified the failure pattern and measured the adhesive layer thickness. The dentin bonding agent (DBS) Single Bond 2 (SB2) (3M ESPE) e Prime&Bond NT (PB) (Dentsply) were tested in two storage times: 48 hours (A) and 4 months (B). Freshly prepared flat dentin surfaces of extracted human molars were coated with the adhesive systems according to the surface treatments groups: G1) aluminum-oxide - SB2; G2) 37% phosphoric acid - SB2; G3) oxide+acid - SB2; G4) aluminum-oxide - PB; G5) 37% phosphoric acid - PB; G6) oxide+acid - PB; G7) control - SB2; G8) control - PB. After curing the DBA, the provisional cement RelyXTemp NE (3M ESPE) was applied to the bonded dentin surface of the groups 1, 2, 3, 4, 5 and 6, and the teeth were stored for 48 hour or 4 months. After the storage, provisional cement layer was scaled off and the different surface treatments were applied followed by a second DBS layer. The control groups (7 and 8) didn’t received the provisional cement neither the second DBS layer, however were stored for the same times.The composite crown restoration was built with direct resin and, after 24h, the prepared teeth were serially sectioned in sticks. The specimens (n=20 per group) were submitted to microtensile strength test using the universal testing machine EMIC DL-2000. The average values (MPa) were (means followed by different letters are statistically different to General Linear Model and Turkey’s test (p<0,05)): G1A - 23,79±5,92(AB); G1B - 23,93±5,49(AB); G2A - 28,47±6,57(B); G2B - 27,84±3,31(B); G3A - 44,84±10,49(C); G3B - 44,37±9,07(C); G4A - 19,14±4,76(A); G4B - 18,51±4,64(A); G5A - 30,60±5,48(B); G5B - 28,30± 3,95(B); G6A - 47,22±10,11(C); G6B - 46,02±10,33(C); G7A - 41,57±6,91(C); G7B - 41,21±9,32(C); G8A - 40,17±10,35(C) e G8B - 41,04±11,21(C). The fractures specimens were analyzed by SEM and the mixed failure was predominant (92%) followed by interfacial failure (21%). The adhesive thickness range in increasing order: G8< G7< G4< G1< G6< G3< G5< G2. These results suggested that: the surface treatment with aluminum-oxide + 37% phosphoric acid provided the highest bond strength values, however the storage times and the DBS didn’t affect these values; the mixed failure was predominant followed by interfacial failure; and the surface treatments affected significantly the bonding layer thickness for both tested DBS. / Este estudo avaliou a influência de diferentes tratamentos de superfície na dentina pré-hibridizada com a técnica do selamento dentinário imediato (SDI) e armazenada por diferentes períodos na resistência de união à microtração de dois sistemas adesivos. Os agentes de união dentinária (AUD) utilizados, Single Bond 2 (SB2) (3M ESPE) e Prime&Bond NT (PB) (Dentsply), foram testados em dois períodos de armazenagem: 48 horas (A) e 4 meses (B). Superfícies planas de dentina foram preparadas em molares humanos extraídos e foram cobertas com o sistema adesivo de acordo com o tratamento de superfície de cada grupo: G1) óxido de alumínio - SB2; G2) ácido fosfórico 37% - SB2; G3) óxido+ácido - SB2; G4) óxido de alumínio - PB; G5) ácido fosfórico 37% - PB; G6) óxido+ácido - PB; G7) controle - SB2; G8) controle - PB. Após a polimerização do sistema adesivo o cimento provisório RelyXTemp NE (3M ESPE) foi aplicado sobre as superficies dentinárias previamente tratadas com adesivo dos grupos 1, 2, 3, 4, 5 e 6 e estes foram armazenados por 48 horas ou 4 meses. Após o período de armazenagem a camada de cimento provisório foi removida e os diferentes tratamentos de superfície foram empregados seguidos de uma segunda camada de AUD. Os grupos controle (7 e 8) não receberam o cimento provisório nem a segunda camada adesiva, sendo no entanto armazenados pelos mesmos períodos de tempo. Coroas de resina composta direta foram construídas e, após 24h, os dentes preparados foram seccionados em palitos. As amostras (n=20 por grupo) foram submetidas ao teste de resistência de união à microtração na máquina de ensaios universal EMIC DL-2000.Os valores médios (MPa) foram (médias seguidas de letras diferentes são estatisticamente diferentes para Modelo Linear Geral e teste de Tukey (p<0,05)): G1A - 23,79±5,92(AB); G1B - 23,93±5,49(AB); G2A - 28,47±6,57(B); G2B - 27,84±3,31(B); G3A - 44,84±10,49(C); G3B -44,37±9,07(C); G4A - 19,14±4,76(A); G4B - 18,51±4,64(A); G5A - 30,60±5,48(B); G5B - 28,30± 3,95(B); G6A - 47,22±10,11(C); G6B - 46,02±10,33(C); G7A - 41,57±6,91(C); G7B - 41,21±9,32(C); G8A - 40,17±10,35(C) e G8B - 41,04±11,21(C). O tipo de fratura foi analisado através de MEV e a falha do tipo mista foi predominante (92%) seguida da falha interfacial (21%). A espessura de adesivo variou em ordem crescente nos grupos: G8< G7< G4< G1< G6< G3< G5< G2. Os resultados sugerem que: o tratamento de superfície com óxido de alumínio + ácido fosfórico 37% proporcionou os maiores valores de resistência de união, no entanto o tempo de armazenagem e o AUD utilizado não afetaram estes valores; a falha mista foi predominante seguida da falha interfacial; e os tratamentos de superfície utilizados afetaram significativamente a espessura da camada adesiva para ambos os AUD testados.
138

Influência do ácido poliacrílico na interface e resistência de união de cimentos resinosos autoadesivos à dentina

Stona, Priscila January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:37Z (GMT). No. of bitstreams: 2 000429330-0.pdf: 4876127 bytes, checksum: 03e0c09981d2813cd511c4f745b49744 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The objective of this study was to evaluate the interface and bond strength of self-adhesives resin cement to dentin pretreated with 11,5% polyacrylic acid. Fifty-six third molars were randomly divided into 7 groups (n=24/group): G1 (control) - Rely X ARC; G2 - RelyX Unicem; G3 - Maxcem Elite; G4 - Set; G5 - polyacrylic acid + Rely X Unicem; G6 - polyacrylic acid + Maxcem Elite; G7 - polyacrylic acid + Set. Resin composite blocks were cemented to flat dentin with a load of 1 kg during 2 minutes, followed by light polymerization. After storage in distilled water at 37ºC for 24 hours, six tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0. 8 mm2. Twenty-four specimens were obtained to each group, and submitted to microtensile bond strength (μTBS) test in an universal testing machine at 0,5 mm/min crosshead speed. Two sets of each group were sectioned mesio-distal in the center of their crown with a diamond blade. The surfaces were polished by wet sanding with 400, 600 and 1200-grit silicon carbide abrasive paper, followed by polishing with 6, 3, 1 and ¼ μm diamond paste. The samples were demineralized, deproteinized, dried, metalized and observed on a scanning electron microscope at 4. 000x. According to ANOVA and Tukey´s test (a=0,05), the mean ZTBS of RelyX ARC (24. 19 MPa) and RelyX Unicem (23. 12 MPa) associated with polyacrylic acid were not significantly different themselves and were superior to other groups (p<0,05).The ZTBS mean of Maxcem Elite associated with polyacrylic acid (13. 09 MPa) was statistically higher to Maxcem Elite without polyacrylic acid (8. 14 MPa). The RelyX Unicem without polyacrylic acid (10. 23 MPa) did not differ statistically from Maxcem Elite with and without polyacrylic acid. All specimens of Set were lost during the cutting procedure. The hybrid layer was not observed for the self-adhesive resin cements, and resin tags were observed for RelyX Unicem, Maxem Elite and when combined with polyacrylic acid. Pretreatment with 11,5% polyacrylic acid was effective for the bond of RelyX Unicem and Maxcem Elite to dentin. / O objetivo desse estudo foi avaliar a interface e a resistência de união de cimentos resinosos autoadesivos à dentina condicionada com ácido poliacrílico a 11,5%. Cinquenta e seis dentes, terceiros molares, foram divididos aleatoriamente em 7 grupos (n=24/grupo): G1 (controle) - Rely X ARC; G2 - RelyX Unicem; G3 - Maxcem Elite; G4 - Set; G5 - ácido poliacrílico + Rely X Unicem; G6 - ácido poliacrílico + Maxcem Elite; G7 - ácido poliacrílico + Set. Blocos de resina composta foram cimentados sobre dentina plana com carga de 1Kg por 2 minutos, seguido de fotoativação. Após armazenagem em água destilada a 37º C por 24 horas, seis conjuntos dente/resina foram cortados, paralelamente ao longo eixo do dente, nos sentidos x e y, com secção de aproximadamente 0,8 mm2. Foram obtidos 24 corpos de prova para cada grupo, sendo então submetidos ao teste de resistência à microtração (RZt) em máquina de ensaio universal com velocidade de 0,5 mm/min. Dois conjuntos de cada grupo foram seccionados no sentido mésio-distal, no centro de suas coroas, com um disco diamantado de dupla face. As superfícies foram polidas com lixas de carbeto de silício 400, 600 e 1200, seguido de polimento com pastas dimantadas de granulação 6, 3, 1 e ¼ μm. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em microscópio eletrônico de varredura em aumento de 4. 000 vezes. De acordo com Análise de Variância e teste de Tukey (a=0,05), a média de RZt do RelyX ARC (24,19 MPa) e do RelyX Unicem associado ao ácido poliacrílico (23,12 MPa) não diferiram estatisticamente entre si e foram superiores aos outros grupos (p<0,05). A média de RZt do Maxcem Elite associado ao ácido poliacrílico (13,09 MPa) foi, estatisticamente, superior ao Maxcem Elite sem ácido poliacrílico (8,14 MPa).O RelyX Unicem sem ácido poliacrílico (10,23 MPa) não diferiu, estatisticamente, do Maxcem Elite sem e com ácido poliacrílico. Todos os corpos de prova do Set foram perdidos durante o procedimento de corte. Para os cimentos resinosos autoadesivos não foi observada formação de camada híbrida, havendo a formação de tags de resina para o RelyX Unicem e Maxem Elite quando associados ao ácido poliacrílico. O pré-tratamento com ácido poliacrílico a 11,5% foi efetivo para a união do RelyX Unicem e Maxcem Elite à dentina.
139

Influência da irradiação com laser nd:yag associado ao flúor nos valores de resistência de união de sistemas adesivos às dentinas sadia e cariada

Paranhos, Maria Paula Gandolfi January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:34Z (GMT). No. of bitstreams: 2 000386672-0.pdf: 7738475 bytes, checksum: 131327351db4ceb85e7af5e5a7ef43e8 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated, in vitro, the microtensile bond strength of two adhesive systems (Single Bond/3M-ESPE and Clearfil SE Bond/Kuraray) to caries affected and normal dentin, with or without previous treatment with Nd:YAG laser or Nd:YAG laser associated to fluoride. Dentin surfaces were exposed from 60 human third molars. Teeth were divided into 12 groups, where groups 1-6 were submitted to pH cycling for artificial caries and groups 7-12 remained with normal dentin. Dentinal surfaces received three different treatments: laser Nd:YAG irradiation (60 mJ, 15 Hz and 0. 9 W) for 1 min; laser Nd:YAG irradiation associated to fluoride in gel; and no treatment (controls). Twelve teeth, treated as mentioned above, were analyzed by SEM, Energy Dispersive Spectroscopy (EDS) and microhardness. In experimental groups, adhesive systems were applied according to manufacturers’ instructions and composite resin restorations (Filtek Z250/3M-ESPE) were made incrementally. After storage in distilled water for 24 h and 37° C, teeth were sectioned serially in both x and y directions and sticks with adhesive area of 0. 8 mm2 were obtained (25 per group). The sticks were measured and submitted to the microtensile bond strength test in an Universal Testing Machine (EMIC DL) in a 0. 5 mm/min crosshead speed. Failure mode was analyzed in SEM and in Fractographical analysis. According to general linear model univariate (GLM) and Tukey (p < 0. 05), the highest mean bond strengths were obtained in groups of normal dentin treated with Clearfil SE Bond (40. 65 MPa) and Single Bond (34. 2 MPa) according to manufacturers’ instructions. The results showed that the presence of caries affected dentin significantly decreased the mean bond strengths of the 2 adhesives systems. Laser irradiation of dentin also decreased the bond strengths of teeth treated with Clearfil SE Bond. Moreover, laser irradiation associated to fluoride also decreased the bond strength values of the 2 adhesive systems. However, caries affected dentin had better results with this association when compared to normal dentin. Mixed failure was the most common mode of failure in this study. SEM analysis showed irregularities and porosities in dentin after Nd:YAG laser irradiation due to melting and re-crystallization of this surface. Normal dentin showed closed dentinal tubules after laser irradiation and caries affected dentin showed clearer dentinal tubules because of the re-establishment of peritubular dentin. / Este estudo avaliou, in vitro, a resistência de união à microtração dos sistemas adesivos Single Bond - SB (3M/ESPE) e Clearfil SE Bond - CSE (Kuraray) à dentina sadia e cariada, com ou sem aplicação prévia do laser Nd:YAG associado ou não a presença de flúor. A superfície oclusal de 60 terceiros molares humanos foi removida para obtenção de uma superfície dentinária plana. Metade destes dentes foram submetidos à ciclagem de pH para realização de cárie artificial e a outra metade permaneceu com a dentina hígida. Os dentes foram divididos em 12 grupos, sendo que a dentina dos grupos 1-6 era cariada e dos grupos 7-12 sadia. Foram realizados 3 tratamentos distintos: irradiação da dentina com laser Nd:YAG (60 mJ, 15 Hz e 0,9 W); irradiação da dentina com laser Nd:YAG associado ao flúor em gel; e sem tratamento (controle). Doze dentes, tratados como descrito acima, foram utilizados para avaliação da microdureza, para análise em MEV e espectroscopia por energia dispersiva (EDS). Nos dentes dos grupos experimentais, a aplicação dos sistemas adesivos foi realizada de acordo com as instruções dos fabricantes e um platô de resina composta (Z250/3M) com aproximadamente 6 mm de altura foi realizado. Após, os espécimes foram armazenados em água destilada por 24 h em uma estufa de cultura a 37°C. Decorrida esta etapa, os dentes foram seccionados nos sentidos “x” e “y” para obtenção de palitos (25 por grupo) com área adesiva de 0,8 mm2. Estes palitos foram submetidos ao ensaio de microtração, em uma máquina de ensaios mecânicos (EMIC-DL), com velocidade de 0,5 mm/min. O padrão de falha foi caracterizado pela análise em MEV e análise fractográfica. Segundo o modelo linear geral univariado (GLM) e Tukey (p < 0,05), as maiores médias foram obtidas quando os sistemas adesivos foram aplicados em dentina sadia, de acordo com as instruções dos fabricantes (SB 34,2 MPa e CSE 40,65 MPa).Os resultados também mostraram que a presença de tecido cariado reduziu significativamente a resistência de união dos dois sistemas adesivos utilizados. A irradiação da dentina com laser diminuiu a resistência de união do Clearfil SE Bond e não afetou os dentes tratados com o Single Bond. A irradiação da dentina sadia com laser associado ao flúor reduziu os valores de resistência de união para os dois sistemas adesivos, embora este tratamento em dentina cariada, utilizando o Clearfil SE 12 Bond tenha mostrado resultados superiores ao Single Bond. O tipo de falha predominante foi a falha do tipo mista. A análise em MEV da dentina sadia, após aplicação do laser, mostrou uma superfície com irregularidades e porosidades devido à fusão e recristalização desta dentina, com túbulos dentinários ocluídos; a dentina cariada apresentou as mesmas características da dentina sadia irradiada, com túbulos dentinários mais nítidos devido à reestruturação da dentina peritubular.
140

Efeito do ultrassom na resistência de união de cimentos resinosos autoadesivos à dentina

Silva, Diego Fabris Ferreira da January 2012 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-05-16T12:10:29Z No. of bitstreams: 1 438292.pdf: 353384 bytes, checksum: e966b89cb4618df13c2f46329c3c7c3f (MD5) / Made available in DSpace on 2012-05-16T12:10:29Z (GMT). No. of bitstreams: 1 438292.pdf: 353384 bytes, checksum: e966b89cb4618df13c2f46329c3c7c3f (MD5) / O objetivo desse estudo foi avaliar a influência da vibração ultrassônica na resistência de união de cimentos resinosos autoadesivos à dentina. Vinte e quatro dentes terceiros molares foram divididos aleatoriamente em quatro grupos (n=6/grupo): G1 – RelyX Unicem; G2 – Maxcem Elite; G3 – RelyX Unicem com vibração ultrassônica; G4 – Maxcem Elite com vibração ultrassônica. Blocos de resina composta foram cimentados sobre dentina plana com carga de 500 g por 2 min, seguido de fotoativação nos G1 e G2. Em G3 e G4, a vibração ultrassônica foi aplicada por 20 s sobre o bloco de resina composta, seguido de carga de 500 g por 1 min e 40 s e fotoativação. Após armazenagem em água destilada a 37º C por 24 h, seis conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos x e y, com secção de aproximadamente 0,8 mm2. Foram obtidos 24 corpos de prova para cada grupo, sendo então submetidos ao teste de resistência à microtração (Rμt) em máquina de ensaio universal com velocidade de 0,5 mm/min. De acordo com Análise de Variância Fatorial, as variáveis tipo de cimento resinoso (p=0,000) e tipo de cimentação (p=0,002) foram significativas. A interação das duas varáveis não foi significativa (p=0,676). De acordo com o teste t-student (α=0,05) a média de Rμt com uso da vibração ultrassônica (13,74 MPa) foi estatisticamente superior sem aplicação da vibração ultrassônica (10,57 MPa)). A média de Rμt do RelyX Unicem (13,95 MPa) foi estatisticamente superior ao Maxcem Elite (10,36 MPa). A vibração ultrassônica aumentou a resistência de união dos cimentos resinosos autoadesivos RelyX Unicem e Maxcem Elite à dentina. / The aim of this study was to evaluate the influence of ultrasonic application on bond strength of self-adhesives resin cements to dentin. Twenty-four third molars were randomly divided into 4 groups (n=6/group): G1 - Rely X Unicem; G2 – Maxcem Elite; G3 – RelyX Unicem and ultrasonic application; G4 – Maxcem Elite and ultrasonic application. Composite resin blocks were luted to flat dentin with a load of 500 g for 2 min, followed by light polymerization in G1 and G2. In G3 and G4, the ultrasonic device was applied for 20 s on the composite resin block, followed by 500 g load for 1 min and 40 s, and light polymerization. After storage in distilled water at 37ºC for 24 h, six tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0.8 mm2. Twenty-four specimens were obtained to each group, and submitted to microtensile bond strength (μTBS) test in an universal testing machine at 0,5 mm/min crosshead speed. According to two-way ANOVA, type of cement factor (p=0.000) and type of luting factor (o=0.002) were significant. The interaction was not significant (p=0676). According to student-t test (α=0.05), the μTBS mean with ultrasonic application (13.74 MPa) was statistically higher than without this treatment (10.57 MPa). The μTBS mean of RelyX Unicem (13.95 MPa) was statistically higher than Maxcem Elite (10.36 MPa). The ultrasonic application increased the μTBS of the RelyX Unicem and Maxcem Elite to dentin.

Page generated in 0.0772 seconds