• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 9
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 813
  • 813
  • 518
  • 484
  • 154
  • 137
  • 126
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Implantes de titânio com superfície tratada a base de β-tricálcio fosfato em levantamento da membrana sinusal. Estudo experimental de superfície, análise biomecânica, histométrica e imunoistoquímica em coelhos / Titanium implants with treated surface by β-tricalcium phosphate in maxillary sinus augmentation. Experimental study of surface, biomechanical, histometric and immunohistochemistry analysis in rabbits

Corrêa, Ana Paula Simões [UNESP] 05 November 2018 (has links)
Submitted by Ana Paula Simões Corrêa (paulinha_odonto@hotmail.com) on 2018-11-23T01:05:30Z No. of bitstreams: 1 FINAL- TESE Doutorado - Ana Paula APÓS CORREÇÃO.docx: 61180781 bytes, checksum: 21ce72e7304ef07d70cef0a07deeb502 (MD5) / Approved for entry into archive by Ana Paula Rimoli de Oliveira null (anapaula@foa.unesp.br) on 2018-11-23T11:22:45Z (GMT) No. of bitstreams: 1 correa_aps_dr_araca_int.pdf: 5040627 bytes, checksum: 59b1e96d9e32e4e66132171e7d64fec2 (MD5) / Made available in DSpace on 2018-11-23T11:22:46Z (GMT). No. of bitstreams: 1 correa_aps_dr_araca_int.pdf: 5040627 bytes, checksum: 59b1e96d9e32e4e66132171e7d64fec2 (MD5) Previous issue date: 2018-11-05 / Fundação de Amparo à Pesquisa do Estado do Amazonas (FAPEAM) / Modificações físicas e/ou químicas das superfícies dos implantes de titânio podem ser realizadas com intuito de facilitar e estimular o processo de osseointegração, consequentemente favorecendo um tempo de reparo mais curto. Sendo assim, o objetivo deste estudo foi avaliar as superfícies de implantes de titânio, modificadas com deposição de β-tricálcio fosfato pelo método biomimético, inseridos na maxila após levantamento de seio maxilar de coelhos, por meio da análise topográfica, biomecânica, microtomográfica, histológica e imunoistoquímica. Dezoitos (18) coelhos da raça Nova Zelândia (Albinus) receberam trinta e seis (36) implantes após elevação da membrana do seio maxilar bilateral. Foram divididos em dois grupos: No Grupo SBF - Implantes com superfícies modificadas pelo tratamento biomimético e preenchimento do seio maxilar esquerdo com coágulo; Grupo TCP - Implantes com superfícies modificadas com deposição de β-tricálcio fosfato pelo método biomimético e preenchimento do seio maxilar direito com coágulo. Os períodos de estudos foram de 7, 15 e 40 dias, onde foram realizadas as avaliações biomecânica, microtomográfica, histométrica e imunoistoquímica. Nas análises físico-químicas de microscopia eletrônica de varredura- MEV, espectroscopia de energia dispersiva- EDS e mapeamento da mineralização observou-se a formação de uma camada de apatita com maiores quantidades de Ca e P nos implantes com deposição biomimética com β-tricálcio fosfato. O teste de molhabilidade monstrou superfícies de alta hidrofilidade neste grupo de implantes. Na interação entre as superfícies dos implantes de Ticp e seu ambiente biológico, a análise biomecânica demonstrou aumentro da estabilidade dos implantes a partir da 2 semana. Foi observada diferença estatisticamente significante na estabilidade (ISQ) no grupo TCP período de 15 e 40 dias (p= 0,08). A análise microtomográfica demonstrou que no período de 15 dias, o grupo TCP apresentou maior volume ósseo – BV (0,16 mm3), fração do volume ósseo em porcentagem - BV/TV (24,70 mm3), número - Tb.n (2,98 mm3) e espessura do trabeculado ósseo - Tb.th (0,082 mm3), quando comparado com o grupo SBF. Foi visualizado na análise histológica a formação de tecido ósseo em ambos os grupos no período de 15 e 40 dias, maior neoformação óssea foi observada no grupo com a superfície dos implantes modificada com β-tricálcio fosfato, embora a análise histométrica da ELCOI e AON não apresentaram diferenças estatísticas (p<0,05). A imunoistoquímica aos 40 dias apresentou marcação moderada no grupo TCP (50%) e leve (25%) no grupo SBF, para a osteocalcina. A incorporação do β-tricálcio fosfato na superfície dos implantes de Ticp, através da modificação do método biomimético, mostrou-se eficiente diante dos testes de avaliação da topografia dos implantes. Observou-se a influência desse tipo de superfície bioativa ao estimular a osseointegração. Sendo assim, uma opção ao tratamento das superfícies dos implantes. / Physical and/or chemical modifications of the surfaces of the titanium implants can be performed in order to facilitate and stimulate the osseointegration process, consequently favouring a shorter repair time. Thus, the objective of this study was to evaluate the surfaces of titanium implants, modified with deposition of β-tricalcium phosphate by the biomimetic method, inserted in the maxilla after lifting the maxillary sinus of rabbits, employing topographic, biomechanical, histological and immunohistochemical analysis. Eighteen (18) New Zealand rabbits (Albinus) received thirty-six (36) implants after bilateral maxillary sinus membrane elevation. They were divided into two groups: In the SBF Group - Implants with surfaces modified by the biomimetic treatment and filling of the left maxillary sinus with clot; Group TCP - Implants with modified surfaces with deposition of β-tricalcium phosphate by the biomimetic method and filling of the right maxillary sinus with clot. The study periods were 7, 15 and 40 days, where the biomechanical, microtomographic, histometric and immunohistochemical evaluations were performed. In the physico-chemical analyzes of scanning electron microscopy (SEM), dispersive energy spectroscopy (EDS) and mapping of mineralization, the formation of an apatite layer with higher amounts of Ca and P was observed in implants with biomimetic deposition with β-tricalcium phosphate. The wettability test showed high hydrophilicity surfaces in this group of implants. In the interaction between the surfaces of the Ticp implants and their biological environment, the biomechanical analysis showed an increase of the stability of the implants from 2 weeks. Statistically significant difference in stability (ISQ) was observed in the TCP group at 15 and 40 days (p = 0.08). The microtomographic analysis showed that in the period of 15 days, the TCP group presented higher bone volume - BV (0.16 mm3), fraction of the bone volume in percentage - BV / TV (24.70 mm3), number - Tb.n ( 2.98 mm3) and bone trabecular thickness - Tb.th (0.082 mm3) when compared to the SBF group. Bone tissue formation in both groups was visualized in histological analysis in the 15- and 40-day periods, with a greater tendency for bone neoformation to be observed in the group with implants surface modified with β-tricalcium phosphate, although histological analysis of ELCOI and AON did not present statistical differences (p <0.05). The incorporation of β-tricalcium phosphate on the surface of the Ticp implants, through the modification of the biomimetic method, proved to be efficient in the evaluation of the topography of the implants. The influence of this type of bioactive surface on osseointegration was observed. Thus, an option to the treatment of implant surfaces. / FAPEAM: 062.03159.2014; Decisão do conselho: 202/2015
112

Estudo da precisão da análise de tomografias espirais de mandíbulas humanas secas realizadas pelo tomógrafo X-Mind Tome

Munhoz, Felipe Camargo [UNESP] 22 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-22Bitstream added on 2014-06-13T18:53:16Z : No. of bitstreams: 1 munhoz_fc_me_araca.pdf: 428760 bytes, checksum: 52e5bedbe2781e905f522cced7cbd981 (MD5) / O sucesso dos implantes dentários depende de um cuidadoso planejamento préoperatório. O exame radiográfico é de fundamental importância na avaliação da morfologia, inclinação óssea e localização de estruturas anatômicas críticas durante os procedimentos de implantação, quando é necessário medir a quantidade de osso disponível. A Tomografia convencional é um exame de extrema importância, pois permite a mensuração da altura e espessura do rebordo alveolar, determinantes na escolha do tamanho do implante. Poucos autores estudaram a influência da variação do movimento tomográfico na qualidade da imagem. O objetivo deste trabalho foi elucidar precisamente as áreas avaliadas pelas imagens fornecidas por tomografias realizadas pelo tomógrafo espiral X-MIND TOME, fabricado em 2005 pela SOREDEX, Helsink, Finlândia. Foram utilizadas dez mandíbulas humanas secas, desdentadas na região dos pré-molares e molares. Os implantes foram posicionados bilateralmente em oito mandíbulas e unilateralmente em duas, com a distância de 4 mm um do outro. Em seguida, cada mandíbula foi adaptada ao tomógrafo, onde foi realizada uma radiografia panorâmica prévia, com magnificação de 50%. Sobre esta radiografia foi colocado um template que determina a região a ser avaliada, sendo realizados cortes de 4mm de largura, nos dois lados da mandíbula. Comparou-se então a solicitação ao tomógrafo com os resultados obtidos, quanto à distância e a ordem dos cortes solicitados. Foram realizadas 19 tomografias que foram avaliadas utilizando-se o programa Radioimp RADIO MEMORY – Belo Horizonte – Brasil. Em seguida, os dados foram tabulados, analisados e estudados estatisticamente, com nível de significância 5%. Através do teste de Wilcoxon, não foram evidenciadas diferenças estatisticamente significantes nos dados obtidos pelas tomografias, sendo, portanto, precisas. / The success of dental implants depends on a carefull pre-opertative planning. The radiographic exam is of main importance for a correct evaluation of morphology, bone inclination and location of critical anatomical structures during the surgical procedures for dental implants, when it’s necessary to measure the amount of available bone. The conventional Tomography is a very important exam, because it allows the measurement of height and thickness of the alveolar bone for the determination of the implant’s size. Few authors studied the influence of the tomographic movement variation in the quality of the image. The aim of the present paper is to clarify the precision of the areas evaluated by the images given by the spiral scanning X-MIND TOME, made in 2005 by SOREDEX, Helsink, Finland. There were used 10 dried mandibles, toothless in the region of pre-molars and molars. The implants were placed in both sides in eight mandibles and in one side in two, with the distance of 4mm one from another. After this, each mandible was placed in the scanning, where a previous panoramic radiograph was taken, with magnification of 50%. Upon this radiograph, it was placed a template to determine the region to be evaluated, where there were made cuts of 4mm of width, in both sides of the mandible. The scanning request was then compared to the obtained results. It was made 19 radiographs that were evaluated using the Radioimp program (RADIO MEMORY – Belo Horizonte – Brazil). The data were then analyzed and studied statistically, with significance of 5%. Throught wilcoxon test, there were not noticed statistical differences in the data obtained in the tomographies, that showed to be precise.
113

Estudo comparativo in vivo de implantes Ti-cp com superfícies comerciais e modificadas por laser sem e com depósito de sílica: análises biomecânica, topográfica e histomorfométrica

Souza, Francisley Ávila [UNESP] 30 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-30Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1 souza_fa_dr_araca.pdf: 2491659 bytes, checksum: 017388e8b7b826e5dad08553556571ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos... / Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was... (Complete abstract click electronic access below)
114

Efeito da plataforma Switching sobre os tecidos peri-implantares: estudo experimental em cães

Scala, Alessandro [UNESP] 09 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-09Bitstream added on 2014-06-13T20:04:02Z : No. of bitstreams: 1 scala_a_dr_araca.pdf: 881800 bytes, checksum: e5815e800d5d9d273ba4ee24380c2131 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: Avaliar a influência da plataforma Switching sobre a remodelação dos tecidos peri-implantares. Material e métodos: Em 6 cães labradores, foram extraídos os pré-molares e primeiro molares inferiores bilateralmente. Após 3 meses de cicatrização, na região correpondente ao 1º molar, foi instalado um implante cônico em cada lado da mandíbula, com o ombro do mesmo posicionado ao nível da crista óssea alveolar vestibular. No lado direito da mandíbula, foi utilizado um pilar de diâmetro reduzido em relação à plataforma do implante, criando uma incompatibilidade de 0,85 milímetros (grupo teste), enquanto no lado esquerdo selecionou-se um pilar do mesmo diâmetro da plataforma do implante (grupo controle). Os retalhos foram suturados permitindo a cicatrização não-submersa. Após 4 meses, os animais foram eutanasiados para obtenção dos cortes histológicos para avaliação histométrica. Resultados: Todos os implantes apresentaram-se completamente osseointegrados. No grupo teste foram observados que os níveis ósseos apresentaram-se superiores ao grupo controle. No entanto, a diferença estatisticamente significativa foi encontrada apenas na região vestibular e na região proximal. A dimensão vertical dos tecidos moles foi maior no grupo controle em comparação ao grupo teste. No entanto, foi encontrada diferença estatisticamente significativa apenas na vestibular. Conclusões: O presente estudo demonstrou diferenças nas dimensões dos tecidos duros e moles peri-implantares (vestibular e proximal) como resultado da incompatibilidade do implante / pilar de 0,85 milímetros, quando o ombro do implante foi posicionado ao nível da crista óssea vestibular / Aim: to evaluate the effect of platform switching on the peri-implant tissue remodeling. Material & methods: Mandibular premolars and first molars of 6 Labrador dogs were extracted bilaterally. After 3 months of healing, 1 tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the alveolar buccal bony crest. On the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used creating a mismatch of 0.85mm (test), while an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment. Results: All implants were completely osseointegrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared to the test sites. However, statistically significant differences were demonstrated only or at the buccal aspects. Conclusions: The present study demonstrated differences in peri-implant (buccal and proximal) hard and soft tissue dimensions as a result of an implant/abutment mismatch of 0.85mm, when the implant shoulder was placed at the level of the buccal bony crest
115

Estudo das dimensões da papila gengival em áreas ântero-superiores adjacentes a implantes unitários

Perez, Fabiano [UNESP] 08 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-08Bitstream added on 2014-06-13T19:05:27Z : No. of bitstreams: 1 perez_f_dr_arafo.pdf: 633248 bytes, checksum: f36ddc620369a8183bf9e6e87d8c059f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O objetivo deste trabalho foi o de comparar as dimensões da papila gengival em áreas restauradas com implantes unitários e áreas com a dentição natural hígida. Além disso, verificou-se a influência da distância da crista óssea até o ponto de contato e da distância da plataforma do implante até a parede axial do dente adjacente sobre a extensão da papila gengival. Para isso, foram selecionados um total de 45 áreas proximais entre dentes naturais e 46 áreas proximais com a presença de implantes unitários. Os pacientes eram, então, submetidos a um exame clínico que tinha por objetivo a constatação da presença total, parcial, ou a ausência da papila gengival nas áreas examinadas. A papila gengival era então classificada em 4 níveis de altura: 0, quando estava totalmente ausente; 1 quando a papila ocupava menos da metade da distância da sua base até o ponto de contato; 2 quando a papila ocupava mais da metade dessa mesma distância, porém não preenchia totalmente o espaço interproximal; e 3 quando todo o espaço interproximal era ocupado pela papila gengival. Depois do exame clínico, os pacientes eram submetidos a tomadas radiográficas sendo que uma tela milimetrada era adaptada junto ao filme para que a imagem radiográfica obtida pudesse ser mensurada mais satisfatoriamente. Depois de obtidas as radiografias, as radiografias foram digitalizadas e as distâncias referentes ao estudo foram feitas por meio de um programa de computador. Com a análise dos dados obtidos, permitiu-se concluir que áreas anteriores superiores restauradas com implantes tendem a apresentar uma papila gengival com menor dimensão do que áreas de dentição natural. / The purpose of this work was to compare the interproximal dental papilla dimension in areas restored with single implants and in areas of natural dentition. The effect of the distance from the contact point to the bone crest and of the distance from the implant platform to the axial face of the adjacent tooth on the papilla extension was also evaluated. Forty five interdental areas and 46 inter-implant areas were selected for the study. The presence (total or partial) or the absence of the interproximal papilla were examined and the following punctuations were made: 0 when the papilla was completely absence; 1 when the papilla filled less then half of the distance between its base and the contact point; 2 when the papilla filled more then half of that distance but not filled the entire of the interdental space; 3 when the whole interdental space was filled by the papilla. After the clinical examination, the patients were submitted to radiographic exams, using a radiographic grid adapted to the film to improve the measurements. The radiographs images were then digitized and the distances related to the study were measured using a computer software. From the data obtained, it was concluded that maxillary anterior areas restored with implants tend to present a smaller interdental papilla then areas of natural dentition. The distance from the contact point to the bone crest (height), the distance between adjacent roots in the natural dentition and the distance between the implant platform and the adjacent root (width) had significant influence on the presence or absence of the interproximal papilla in both groups evaluated.
116

Usinabilidade e integridade superficial de implantes dentários

Manera, Rodolfo da Silva [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-05-14T16:59:32Z : No. of bitstreams: 1 000825077.pdf: 1075325 bytes, checksum: 119b03cd57fb8fa0c0fee869067e2d35 (MD5) / Ligas metálicas destinadas a implantes, de um modo geral, têm sido cada vez mais pesquisadas quanto às suas propriedades mecânicas, microestruturais e características de biocompatibilidade. Apesar do surgimento de inúmeros materiais poliméricos, o titânio e suas ligas representam ainda a grande gama de aplicações na área da implantodontia. O titânio é considerado um material de difícil usinabilidade, pois desenvolve altas tensões e temperaturas em uma área de corte 2/3 menor que a de outros materiais. Assim, os parâmetros de usinagem e a ferramenta de corte necessitam ser adequadamente especificados, pois tanto a matéria-prima quanto o processo de fabricação levam a um alto valor agregado do produto final. Este trabalho determinou os efeitos da velocidade de corte e da profundidade de usinagem na usinabilidade (força de corte e energia específica de corte) e integridade superficial (microdureza e acabamento) no roscamento de implantes dentários de titânio comercialmente puro (grau 4, ASTM F67). Os ensaios foram realizados em torno CNC de cabeçote móvel, empregando ferramenta de metal duro revestida de TiAlN e fluido de corte abundante. Com base na Análise de Variância (ANOVA), os resultados mostraram que os parâmetros de corte afetam a usinabilidade e a integridade superficial da rosca, sendo a profundidade de usinagem o fator mais influente. Níveis muito baixos ou altos da profundidade de usinagem elevam a energia específica e a força de corte, respectivamente, encruando a subsuperfície da rosca e prejudicando a rugosidade dos flancos dos filetes. Velocidades de corte menores tendem a aumentar a força e a energia específica de corte, prejudicando o acabamento da rosca, mas não influem em sua dureza. Rugosidades estatísticas Skewness e Kurtosis apontaram a prevalência de picos agudos na superfície da rosca, favorecendo a osseointegração. Testes na condição High-Speed Cutting (HSC) indicaram ... / Metallic alloys applied to implants have been researched aiming at improving their mechanical properties, microstructure and biocompatibility. Despite appearing several types of polymers in the last years, titanium and its alloys are still used extensively in the implantology. Titanium is considered a hard-to-cut material, because it develops high stresses and temperatures in a small cutting area (2/3 smaller than for other materials). Thus cutting parameters and tools need to be specified properly, since both raw material and manufacturing process increase the costs of the final product. This research determined the effects of cutting speed and depth of cut on machinability (cutting force and specific cutting energy) and surface integrity (microhardness and roughness) when threading pure commercially dental implants (grade 4, ASTM F67). Machining tests were carried out in a CNC lathe by applying TiAlN coated carbides and cutting fluid. Based on Analysis of Variance (ANOVA), the main results indicated that cutting parameters influence on machinability and surface integrity of the implant screw, being depth of cut the more influent. Low and high levels of depth of cut increase specific cutting energy and cutting force, respectively, hardening the screw subsurface and damaging the roughness of the thread flanks. Lower cutting speeds trend to raise both cutting force and specific cutting energy, damaging the screw finishing, but they do not affect its subsurface microhardness. Skewness and Kurtosis roughness parameters indicated the predominance of spiky surface on screw which is favorable to osseointegration. Tests at High-Speed Cutting (HSC) showed it is possible to machine implant screws, but depth of cut cannot be high so that avoiding vibration in threads
117

Efeito da aplicação de filmes de carbono tipo diamante por plasma no destorque de pilares de implantes com conexões cônicas internas

Coelho, Arianne Vallim Pinto [UNESP] 07 August 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-07. Added 1 bitstream(s) on 2015-06-18T12:48:55Z : No. of bitstreams: 1 000826366.pdf: 2139319 bytes, checksum: 7c1587e5da8c47a208fed4769c228802 (MD5) / O estudo avaliou o efeito da aplicação de dois filmes de Carbono tipo Diamante por plasma no torque reverso dos pilares protéticos submetidos à ciclagem mecânica e analisou a adaptação do pilar e de suas roscas em relação ao implante, bem como a deformação gerada nas roscas dos pilares e nas roscas internas dos implantes. Para tal, foram utilizados 60 conjuntos de implantes de conexão cônica interna (CCI) de 11º e 8º e pilares de corpo único de titânio que foram divididos em seis grupos (n=10): GC-8 (controle) - CCI 8º sem tratamento; DLC-8 - CCI 8º com aplicação de filme de carbono tipo diamante (DLC); AgDLC-8 - CCI 8º com aplicação de filme de carbono tipo diamante dopado com nano partículas de prata (AgDLC); GC-11 (controle) - CCI 11º sem tratamento; DLC-11 - CCI 11º com aplicação de filme de carbono tipo diamante (DLC); AgDLC-11 - CCI 11º com aplicação de filme de carbono tipo diamante dopado com nano partículas de prata (AgDLC). Os filmes foram depositados por meio do processo de Deposição Química a Vapor Assistida por Plasma (PECVD). Os pilares receberam o aperto controlado por um dispositivo de controle de torque digital seguindo as recomendações do fabricante. O teste de fadiga foi conduzido seguindo os parâmetros especificados na norma ISO 14801 com uma carga de 120 Ncm a 2 Hz por 2 x 106 ciclos. Ao final dos ciclos, o valor de destorque dos pilares foi registrado. Análises por Microscopia Eletrônica de Varredura (MEV) foram realizadas em três amostras de cada grupo, antes e após a ciclagem mecânica, para verificar se a adaptação do pilar (corpo e roscas) ao implante foi afetada pela aplicação dos filmes. A caracterização dos filmes foi realizada por meio de análises Tribológicas, bem como por Espectroscopia Raman e Espectrometria de Energia Dispersiva de Raios-X (EDS). Todos os grupos mostraram redução nos valores de torque reverso. O grupo DLC-8 foi o ùnico a apresentar... / This study evaluated the effect of the plasma deposition of two diamondlike carbon thin films (DLC) on the reverse torque and adaptation of prosthetic abutments after mechanical cycling. Sixty sets of 11º e 8º tapper connection implants (TCI) and titanium solid abutments were divided in six groups (n=10): GC-8 (control) - 8º TCI with no film deposition; DLC-8 - 8º TCI with DLC deposition; AgDLC-8 - 8º TCI with silver doped DLC (AgDLC); GC-11 (control) - 11º TCI with no film deposition; DLC-11 - 11º TCI with DLC deposition; AgDLC-11 -11º TCI with silver doped DLC (AgDLC); The films were deposited by Plasma Enhanced Chemical Vapor Deposition (PECVD) process. The abutments were tightened with a controlled torque meter device following the manufacturer's recommendations. Mechanical cycling was carried out with a load of 120 Ncm during 2 x 106 cycles with a frequency of 2 Hz (ISO 14801). Afterwards, detorque was measured. Analyses with Scanning Electron Microscopy (SEM) were conducted on three samples of each group before and after mechanical cycling in order to verify the adaptation of the abutments (body and threads). Tribology analyses, as well as Raman Spectroscopy and Energy-Dispersive X-rays Spectroscopy (SDS) analyses were performed for characterization of the different surface treatments. All groups demonstrated reduction of reverse torque values. DLC-8 was the only group that showed an increase on the average reverse torque values
118

Efeito da administração de alendronato, a longo prazo, sobre as propriedades mecânicas do tecido ósseo, sua reparação e mineralização ao redor de implantes osseointegráveis. Estudo em ratas

Verzola, Mario Henrique Arruda [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28. Added 1 bitstream(s) on 2015-06-18T12:48:48Z : No. of bitstreams: 1 000830290_20170328.pdf: 71548 bytes, checksum: 1482e1bc5082299166a7c62f366c8a4f (MD5) Bitstreams deleted on 2017-03-31T12:19:17Z: 000830290_20170328.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:21Z : No. of bitstreams: 1 000830290.pdf: 1153430 bytes, checksum: cfa5ae52217192f227b37867f3b21bd4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve como objetivo avaliar, em ratas, o efeito da terapia a longo prazo com bifosfonato sobre o processo de reparo e mineralização óssea ao redor de implantes e sobre as propriedades mecânicas do tecido ósseo. Para isso, 160 ratas foram distribuídas aleatoriamente em 2 grupos: grupo alendronato (ALD), no qual os animais receberam administração subcutânea de alendronato uma vez por semana, e grupo controle (CTL), no qual os animais receberam administração semanal de placebo, durante todo o período experimental. Após 120 dias do início do tratamento, um implante de titânio foi instalado na metáfise tibial, de ambos os lados. Dez animais de cada grupo foram sacrificados nos dias 5, 10, 15, 20, 25, 30, 45 e 60 pós-cirurgia, sendo retirados os fêmures e as tíbias. Os fêmures foram avaliados quanto à densitometria óssea e testes mecânicos. As tíbias contendo os implantes foram avaliadas quanto ao torque de remoção, análise histométrica (%BIC e %BAFO), microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS), mapeamento da mineralização além de arranjo e distribuição do colágeno. Os resultados quanto à densitometria óssea demonstraram maiores valores para os animais do grupo ALD em relação ao grupo CTL, em todos os períodos de avaliação, com exceção do período de 15 dias. Os resultados dos testes mecânicos, de forma geral, demonstraram maior resistência à fratura (força máxima) e maior capacidade de absorção de energia (tenacidade) no grupo ALD em relação ao grupo CTL até o período de 45 dias. Para a rigidez, no período de 45 dias o grupo ALD apresentou valores significativamente maiores, entretanto sem diferença entre os grupos aos 60 dias. Em relação à resiliência, o grupo ALD demonstrou valores significativamente maiores somente no período de 45 dias. A droga influenciou no torque de remoção... (Resumo completo, acesse link abaixo) / The aim of this study was evaluate in female rats, the effect of long-term therapy with bisphosphonate on the healing process and bone mineralization around implants and on the mechanical properties of bone tissue. One hundred sixty female rats were randomly allocated into two equally sized groups: the alendronate (ALD) group, which received the subcutaneous administration of alendronate (1 mg/kg/week), and the control (CTL) group which the animals received weekly the subcutaneous administration of saline solution (placebo) for the entire experimental period. After 120 days of the treatment initiation, in the booth groups, one titanium implant was installed in the tibia metaphysis. Ten animals in each group were euthanized at: 5, 10, 15, 20, 25, 30, 45, or 60 days after surgery, and their femurs and tibias were removed. The femurs were evaluated regarding bone mineral density (BMD), and mechanical tests. The tibias samples with the implants were evaluated by removal torque, histometric analysis (% BIC and % BAFO), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), mapping of mineralization and arrangement and distribution of the collagen. The results regarding bone densitometry showed higher values for the animals of ALD group compared with the CTL group at all evaluation periods, except for the period of 15 days. The results of mechanical tests, in general, showed higher fracture resistance (maximum force) and higher capacity of energy absorption (tenacity) in the ALD group compared with the CTL group until the 45 day. In the 45 days, the stiffness showed significantly higher values in the ALD group, however at 60 days no difference was observed between the groups. Regarding the resilience, the ALD group showed significantly higher values in the 45 days. The drug influenced the removal torque of implants with significantly higher values for ALD group until ...(Complete abstract electronic acess below)
119

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal

Medeiros, Rodrigo Antonio de [UNESP] 17 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-17Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000799687.pdf: 2318580 bytes, checksum: 6de6ec46da88b8b9d6b603ce2ab8f4be (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 – UCLA e barra metálica; Grupo 2 – UCLA e revestimento oclusal em resina acrílica; Grupo 3 – UCLA e revestimento em cerâmica; Grupo 4 – Intermediário e barra metálica; Grupo 5 – Intermediário e revestimento em resina acrílica; Grupo 6 – Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / FAPESP: 12/11336-7
120

Análise da distribuição das tensões em próteses protocolo mandibulares com estruturas fresadas por CAD/CAM e confeccionadas pela técnica convencional : análise pela fotoelasticidade e extensometria /

Medeiros, Rodrigo Antonio de. January 2016 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Aldiéris Alves Pesqueira / Banca: Daniela Micheline dos Santos / Banca: Marcela Filié Haddad / Mario Alexandre Coelho Sinhoreti / Resumo: O objetivo desse estudo foi avaliar a distribuição de tensão, por meio dos métodos fotoelástico e extensometria, em próteses p rotocolo mandibulares (tipo Branem ä rk) com infra estruturas confeccionadas com difer entes materiais e técnica s, sob força de compressão. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula que recebeu cinco implantes 4x11 mm hexágono externo entre os forames mentonianos. Os gr upos foram divididos em: Grupo I - infraestrutur a fundida em níquel - cromo com revestimento ocl usal em resina acrílica (n=7); Grupo II - infra estrutura fundida em níquel - cromo com revestimen to oclusal em cerâmica (n=7); Grupo III - infra estrutura fresada em Zircônia estabilizada por óxido de í trio com revestimento em cerâmica (n=7). Inicialmente, foi realizado o teste da fotoelasticidade e, posteriormente, a extensometria. Pela metodologia da fotoelasticidade, c om auxílio de uma máquina de ensaio universal (EMIC) foram aplicadas cargas axiais d e 70 N na região do implante mais anterior, entre os incisivos, e no centro do primeiro molar de cada lado. Por meio de imagens fotográficas e com o auxílio do programa Adob e Photoshop CS6, as imagens foram analisadas de acordo com o número de franjas de a lta intensidade nos grupos testados. Para a Tese de Doutorado Resumo metodologia da extensomet ria, as cargas foram aplicadas da mesma maneira da metodologia da fotoelasticidade e a medição das tensões foi realizada em duas regiões distintas. Para a primeira região, dois extensômet r os elétricos de resistência foram posicionados horizontalmente na região mesial e distal dos cinco implantes, diretamente sobre a crista marginal do modelo fotoelástico. Para a segunda re gião, a resina fotoelástica foi removida d a superfície vestibular e lingual de cada implante, sendo mantida1 mm de resina (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the stress distribution in full - arch fixe d mandibular prosthesis (Branemä rk type) with infrastructure made of different materials and techniques, and under compressive force, through photoelastic and strain gauge analysis. A photoelastic cast of an edentulous jaw was fabricated and received five ex ternal hexagon implants (4x11mm) between the mental foramen. The groups were divided into: Group I - Nickel - Chrome fused infrastructure with acrylic resin occlusal coating; Group II - Nickel - Chrome fused infrastructure with ceramic occlusal coating; Group III - Yttria - stabilized zirconia fused infrastructure with ceramic coating. First, the photoelastic analysis was performed and later the strain gauge analysis. A force of 70 N was applied by using a testing machine (EMIC) in the region of the most anterior implant, between incisors, and in the center of the first molar on each side. The images were analyzed by a blinded evaluator through images and by using Adobe Photoshop CS6, according to the number of high intensity fringes in each group. Regarding the s train gauge analysis, the stress measure was performed in two distinct regions. For the first region, two resistance strain gauges were placed horizontally in the mesial and distal regions of the five Tese de Doutorado Abstract implants, directly on the marginal ridge of the photoel astic cast. For the second region, the photoelastic resin was removed on the buccal and lingual surfaces of each implant, leaving 1 mm of intact resin, where the strain gauges were placed vertically. The same compression tests described above were carried out. Data were submitted to two - way ANOVA and to the Tukey post - hoc test with 5% level of significance. The results of both methods showed lower stress values for Group I, when compared to other groups. It can be concluded (Complete abstract electronic access below) / Doutor

Page generated in 0.1003 seconds