• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 29
  • 16
  • 3
  • Tagged with
  • 92
  • 92
  • 29
  • 21
  • 17
  • 14
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Shear Strength Between Adhesive Cement and Yttria-Stabilized-Zirconia and Cobalt-Chrome Alloy With and Without Retentive Holes - an in vitro study

Issa, Rihan, Acar, Nuray January 2017 (has links)
ABSTRACT De-bonding is the most common failure of resin-bonded fixed partial dentures. The aim was to determine if the shear bond strength (SBS) differed between a dental adhesive and a Co-Cr alloy and an yttria-stabilized zirconia (Y-TZP). Furthermore, to determine whether retention holes in the two materials and storage for 21 days in water affected the results. The hypothesis was that there are no significant differences between the compared groups. 10 embedded discs of Co-Cr alloy without and 10 with retentive holes, and 10 discs of Y-TZP without and 17 with retentive holes were sand- and steam blasted. A pillar of adhesive cement was bonded to the surface of the discs and stored in water at 37 °C for 24 hr and / or 21 days. An UltraTest machine with a crosshead speed of 1 mm/ min was used for SBS. The mean SBS after 24 hr / 21 days in water were recorded. The SBS of Co-Cr alloy without retentive hole was 16.3 MPa after 24 hr and 11.4 MPa after 21 days, the SBS of Y-TZP without retentive hole was 18.5 MPa after 24 hr and 12.6 MPa after 21 days. The SBS of Co-Cr alloy with retentive hole 13.9 MPa after 21 days and Y-TZP with retentive hole 16.9 MPa after 21 days. No statistically significant differences were found between the groups with or without retentive holes and after 24 hr or 21 days in water, p> 0.05.
82

« Développement d'un système universel de coulée d'alliages dentaires par centrifugation axiale à très haute vitesse sous vide secondaire » / "Development of a universal system for dental alloys casting by axial centrifugation at high speed and secondary vacuum "

Lopez, Isabelle 23 May 2013 (has links)
La fabrication de prothèses dentaires à base de titane a connu un réel essor ces dernières années. Cependant, la production de ces produits reste assez coûteuse, et le choix de producteurs est encore restreint. Les partenaires du projet de recherche Européen Den-ticast® ont identifié un fort potentiel pour la création d'une machine innovante, capable de produire ces pièces à un coût réduit et à un niveau de qualité élevé. Le projet est axé sur le domaine de la production de pièces de métal pour l'usage dentaire, avec comme objectif, le développement d'un nouveau système polyvalent de coulée des alliages, qui doit permettre de couler l'ensemble des alliages dentaires actuellement commercialisés (NiCr, CoCr), mais aussi le titane et ses alliages. Le prototype Denticast® associe, pour la première fois, la fusion par induction et l'injection par centrifugation à haute vitesse, sous vide secondaire. Entièrement programmable, cette machine doit pouvoir évoluer en fonction du développement de nouveaux alliages sur le marché dentaire.Ce projet réunit des partenaires européens de 3 pays différents (France, Allemagne, Italie) et 3 secteurs d'activité : industriel, académique et odontologique, de sorte que chacun ap-porte un aspect complémentaire au projet. Il comporte 3 phases principales : une phase d'étude, une phase de conception et une phase d'évaluation du prototype.Nos résultats montrent que Denticast® est capable de produire des pièces à usage dentaire de qualité, à grains fins et homogènes, avec un niveau de contrainte résiduelle relativement bas, et une fraction volumique de porosité faible. Les caractéristiques mécaniques sont globalement supérieures ou équivalentes aux systèmes commerciaux du marché. / Although the manufacture of titanium dental prostheses has experienced a real rise in the last years, the production of those products remains quite expensive, and the choice of pro-ducers is still limited. The partners of the European research project Denticast® have identi-fied a high potential for the creation of an innovative machine that can produce those dental parts at low cost and high quality level. The aim of this research is the development of a new, innovative and versatile system of casting alloys, which can cast all dental alloys (NiCr, CoCr) as well as titanium and its alloys. The prototype Denticast® associates for the first time the melting by induction and the injection by centrifugation with high speed under vacuum. Totally preset, this machine should be able to evolve according to the devel-opment of new dental materials.The project combines European partners from 3 different countries (France, Germany and Italy) and three sectors: industrial, academic and dental, so that each of them contributes to the project. It presents three main phases: a study phase, a phase of design and the evalua-tion phase of the prototype.Our results show that Denticast® is able to produce quality parts for dental use with a ho-mogeneous and fine grain, with a low level of residual stress and a relatively low volume of fraction porosity. In most cases, the mechanical characteristics are equal or even greater than other systems on the market at present.
83

Etude métallographique et électrochimique des alliages et brasures utilisés en prothèse fixée dentaire céramo-métallique / Métallographic and electrochemical study of alloys and solders used in metal-ceramic fixed partial dentures

De March, Pascal 17 February 2011 (has links)
Cette recherche porte sur l'étude métallographique et électrochimique des brasures primaires et secondaires pour huit alliages employés en prothèse fixée dentaire (cinq de haute noblesse, un noble et deux non nobles) et leurs brasures correspondantes réalisées de façon conventionnelle. Des soudures laser ont également été réalisées. La première partie de l'étude concerne la caractérisation des propriétés des alliages et des brasures sur le plan de leurs propriétés physiques, de leur microstructure, de leur comportement mécanique. L'étude a révélée notamment qu'il pouvait exister des défauts métallurgiques plus ou moins important au sein des alliages parent et des zone de liaison métallurgiques. Une deuxième partie de l'étude porte sur le comportement électrochimique des alliages et brasures secondaires dans différents types d'électrolyte simulant la salive. Les alliages sont étudiés individuellement et en couplage galvanique. Leur comportement en corrosion est ainsi analysé. Ces études montrent que tous les alliages étudiés (y compris les non nobles) présentaient une très grande résistance à la corrosion / This study deals with metallographic and electrochemical properties of eight parent alloys used in fixed partial denture (five High Noble, one Noble and two predominantly based alloy), and their corresponding pre- and post-solder realized in conventionnal way. Laser solder have also been realized. In the fisrt part of the study, parent alloys and their corresponding solders were caracterized by considering their physical properties, microstructure and mechanical aspect. Different types of internal defects were noticed in several parent alloys and solder joints. The second main aspect of the study concerns electochemical comportement of parents alloys and their post-solders alloys in diffent in several types of electrolyte simulating articificial saliva. Parent alloys are study individually and in galvanic coupling conditions. The results show that all alloys of the study (predominantly based alloys inclued) are very corrosion resistant
84

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Rodrigo Tiossi 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92μm), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10μm e Ti cp: 48,41 ± 26,69μm). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76μm, Ni-Cr: 20,13 ± 7,97μm, e Ti cp: 22,28 ± 17,29μm, e no lado contrário: Co-Cr: 118,64 ± 91,48μm, Ni-Cr: 70,66 ± 20,88μm, e Ti cp: 118,56 ± 51,35μm. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08μm). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81μm) e Ti cp (17,70 ± 11,70μm), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36μm) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15μm) e em Ti cp (40,42 ± 27,14μm) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67μm, após a simulação, quando era 41,02 ± 26,15μm após soldagem a laser para o primeiro e, 40,42 ± 27,14μm e 28,05 ± 20,89μm, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92μm), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10μm e Cp Ti: 48.41 ± 26.69μm). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76μm, Ni-Cr: 20.13 ± 7.97μm, and Cp Ti: 22.28 ± 17.29μm, and on the opposite side: Co-Cr: 118.64 ± 91.48μm, Ni-Cr: 70.66 ± 20.88μm, and Cp Ti: 118.56 ± 51.35μm. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08μm). For the other two groups, Ni-Cr alloy (13.10 ± 1.81μm) and Cp Ti (17.70 ± 11.70μm), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36μm) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15μm) and the Cp Ti (40.42 ± 27.14μm) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67μm, after simulation, when was 41.02 ± 26.15μm after laser welding for the first and, 40.42 ± 27.14μm and 28.05 ± 20.89μm, before and after, for the second, though not showing any statistically significant differences.
85

Étude des matériaux de reconstruction prothétique odontologique en salive artificielle / Study of dental prosthetic materials in artificial saliva

Helfer, Maxime 09 October 2012 (has links)
En odontologie, la perte d'éléments naturels est palliée par l'utilisation de biomatériaux de reconstruction d'origine métallique ou céramique, celle-ci connait actuellement un fort développement avec une propension à supplanter le métal pour n'avoir que du « tout céramique ». Ces matériaux sont, par leur fonction, amenés à séjourner durablement dans le milieu buccal favorisant l'apparition de phénomènes corrosifs. La salive est un électrolyte efficace auquel viennent s'ajouter les variations de pH, de température, le polymétallisme, augmentant la vitesse de corrosion et le relargage des éléments constituants. L'étude porte sur cinq alliages couramment utilisés en odontologie prothétique : un précieux, un semi précieux et trois non précieux, et des céramiques d'infrastructure, visant à remplacer les alliages : zircone, alumine et disilicate de lithium. Tous les échantillons subissent en statique une attaque salivaire, et en dynamique une combinaison d'action salivaire et d'usure grâce à une machine unique, simulant le plus précisément possible les mouvements cuspidiens en présence constante de salive artificielle reproduisant de très près les conditions intra-buccales. L'analyse des échantillons au M.E.B.et les résultats de la spectrométrie montrent au niveau alliage un excellent comportement du Cr Co et du titane. Les céramiques montrent aussi des propriétés remarquables sur le plan biologique infirmant pour certaines les ressentis cliniques. Par contre une usure importante des dents naturelles antagonistes ne leur confère pas une biocompatibilité parfaite / In dentistry, the loss of natural elements is made up for by the use of reconstruction biomaterials of metal or ceramic origin. The use of the latter is now fastly developing and tends to supersede metal, to have only "all ceramic" elements. All these materials will remain in the mouth of the patients for a long time, which creates optimal conditions for the appearance of corrosion phenomena. Saliva is indeed an effective electrolyte. The variations in pH, temperature and polymetalism increase the speed of corrosion and the release of the component elements. The present study concerns five alloys usually used in prosthetic dentistry: one noble, one high noble, three basic alloys and several ceramics of infrastructure to replace alloys: zirconia, alumina and lithium disilicate. All the samples undergo a salivary attack in statics, and a combination of salivary action and wear in dynamics thanks to a unique machine, simulating as exactly as possible the buccal conditions. The analysis of the samples in the S.E.M., as well as the spectrometry results, suggest that the Co-Cr alloy and titanium present an excellent behaviour. Ceramics also show remarkable properties on the biological plan, in spite of certain people's clinical experience. However, an important wear of the opposing natural teeth does not give them a perfect biocompatibility
86

Análise por elementos finitos de próteses tipo protocolo com diferentes materiais de infraestrutura e instaladas em rebordo reabsorvido / Finite element analysis of implant-supported prostheses with different infrastructure materials and installed in reabsorbed ridge

Zaparolli, Danilo 08 February 2018 (has links)
Com o avanço da estética e da qualidade de vida, novos materiais estão sendo utilizados para substituir partes metálicas de próteses, e mais pacientes com rebordos atrofiados desejam uma reabilitação oral fixa. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas mandibulares em função da variação do material utilizado nas barras e da largura do rebordo ósseo, através de análise por elementos finitos. Dois hemiarcos mandibulares (normal e reabsorvido) foram modelados em software de computador. Dois implantes cone-morse foram inseridos em cada mandíbula, sendo reabilitados com prótese do tipo protocolo. Três materiais diferentes de barra foram utilizados: cobalto-cromo, titânio e resina reforçada por fibras de vidro. Cada prótese recebeu 500N de força oblíqua distribuída entre molar (200N) e pré-molares (150N cada). A função espelho do software de análise foi utilizada para transformar cada hemiarco em arcada total. Foram analisadas as tensões máximas e mínimas principais no osso cortical e trabecular, e a tensão equivalente Von mises na infraestrutura e componentes da prótese. A variação dos materiais de infraestrutura provocou alteração na magnitude das tensões, mas não de forma significativa e nem alterando a forma de distribuição das tensões. Já a quantidade remanescente de rebordo ósseo alterou de forma significativa tanto a magnitude quanto a distribuição das tensões máximas e mínimas principais: no implante anterior localizadas somente no pescoço do implante para a mandíbula normal e no pescoço e espiras do implante para a mandíbula reabsorvida; no implante posterior houve apenas diferença significante de intensidade das tensões, não de localização. A tensão equivalente Von mises se concentrou no micro-unit em todas as situações, sendo mais alterada pela diferença de rebordo do que de material de infraestrutura. Pode-se concluir que tanto a variação da condição do rebordo ósseo remanescente como a variação do a variação do material de infraestrutura da prótese provocaram alterações na intensidade e distribuição das tensões, sendo que a primeira provocou alterações mais significativas do que a segunda / With the advancement of aesthetics and quality of life, new materials are being used to replace metallic parts of prostheses, and more patients with atrophied ridges want a fixed oral rehabilitation. The aim of this study was to compare the stress generated by mandibular implant - supported prostheses in function of the variation of the material used in the bars and the width of the bone ridge, through finite element analysis. Two mandibular hemi arcs (normal and reabsorbed) were modeled in computer software. Two cone-morse implants were inserted into each mandible, being rehabilitated with a implant-supported prostheses. Three different bar materials were used: cobalt-chromium, titanium and fiberglass reinforced resin. Each prosthesis received 500N of oblique load distributed between molar (200N) e and premolars (150N each).. The mirror function of the analysis software was used to transform each hemi arch into total arch. We analyzed the maximum and minimum principal tensions in the cortical and trabecular bone, and the equivalent stress Von mises in the infrastructure and components of the prosthesis. The variation of the materials of infrastructure caused a change in the stress magnitude, but not in a significant way nor changing the form of stress distribution. On the other hand, the remaining amount of bone ridge significantly altered both the magnitude and the distribution of the maximum and minimum principal stresses: in the anterior implant located only in the neck of the implant for the normal mandible and in the neck and spines of the implant for the reabsorbed mandible; in the posterior implant there was only a significant difference in the intensity of the stresses, not in the location. The equivalent stress Von mises was concentrated in the micro-unit in all situations, being more affected by the ridge difference than of infrastructural material. It can be concluded that both the variation of the condition of the remaining bone ridge or the variation of the variation of the infrastructure material of the prosthesis caused changes in the intensity and distribution of the stresses, being so that the first caused more significant alterations than the second
87

Avaliação de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias / Evaluation of experimental titanium alloys for prosthodontic frameworks

Queiroz, Adriana Cláudia Lapria Faria 29 May 2009 (has links)
A utilização do titânio em odontologia tem aumentado devido suas propriedades mecânicas, biocompatibilidade, resistência à corrosão e baixo peso específico. Entretanto, o uso do titânio em próteses ainda não é rotineiro em virtude de dificuldades no processo de fundição. Uma das maneiras de superar estas dificuldades seria através do desenvolvimento de novas ligas cujo ponto de fusão fosse inferior ao do Ti cp. O objetivo deste estudo foi avaliar as propriedades mecânicas, biológicas e microestrutura de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias, após fundição odontológica, comparando-as ao Ti cp. As ligas experimentais avaliadas foram Ti-5Zr(%p), Ti-5Ta(%p) e Ti-5Ta-5Zr(%p). Os corpos-de-prova foram fundidos por arco voltaico em atmosfera de argônio e injeção por vácuo-pressão. Para avaliação das propriedades mecânicas, corpos-deprova em forma de halteres foram submetidos a ensaios de tração, barras foram submetidas a ensaios de flexão para avaliação do módulo de elasticidade, e hemi-esferas e discos foram submetidos ao teste de desgaste de dois corpos, sendo o perfil das amostras avaliado antes e após o teste para cálculo da perda de altura vertical. Discos foram utilizados para avaliação da microdureza e para caracterização microestrutural. Para avaliação das propriedades biológicas, células SCC9 foram cultivadas em meio de cultura D-MEM/HF12 suplementado sobre discos e poços sem discos foram usados como controle. Após períodos de 1, 4, 7, 10 e 14 dias, foi avaliada a proliferação celular pelo método histoquímico MTT. Aos 7 dias foi avaliada a viabilidade celular após marcação com azul de Trypan e contagem em hemocitômetro. A morfologia celular foi avaliada às 2, 12 e 24 horas através da visualização, em microscópio de fluorescência por epiluminação, do citoesqueleto de actina e dos núcleos, usando, respectivamente, faloidina e DAPI. Os resultados foram submetidos a testes estatísticos e a liga Ti-5Ta apresentou resistência à tração menor que as demais e módulo de elasticidade significativamente menor do que o Ti cp, embora não diferente das demais ligas experimentais. Com relação à resistência à abrasão, as ligas experimentais apresentaram desgaste significativamente menor do que o Ti cp e a liga Ti-5Zr apresentou microdureza significativamente maior do que os demais materiais. Não houve diferença na proliferação e na viabilidade celular entre os materiais. A avaliação da morfologia celular mostrou diferença na proporção de células nos diferentes estágios de desenvolvimento nos períodos de 2 e 12 horas, mas não em 24 horas. O Ti cp apresentou microestrutura do tipo feather-like com fase α, enquanto Ti-5Zr apresentou estrutura do tipo Widmanstätten com fase α e α´. As ligas Ti- 5Ta e Ti-5Ta-5Zr apresentaram as fases α, α´, α´´ e β, com arranjos lamelar e acicular, respectivamente. Os resultados deste estudo sugerem que as ligas estudadas apresentam potencial para aplicação em próteses dentárias, uma vez que suas propriedades biológicas foram semelhantes às do Ti cp, comprovado por proliferação, viabilidade e morfologia celular; e suas propriedades mecânicas, como resistência à abrasão, microdureza e resistência à tração foram satisfatórias, ainda que o módulo de elasticidade possa e deva ser melhorado. / The use of titanium in dentistry have increased due to its mechanical properties, biocompatibility, corrosion resistance and density. However, titanium has not been routinely used because of the difficulties related to casting technique. One of the options to solve these difficulties would be to develop new titanium alloys whose melting point was lower than cp Ti. So, the aim of this study was to evaluate the mechanical and biological properties and microstructure of experimental titanium alloys for prosthesis frameworks, after dental casting, comparing to cp Ti. The experimental alloys evaluated were Ti-5Zr(%w), Ti-5Ta(%w) and Ti-5Ta-5Zr(%w). The samples were cast by voltaic arc in argon atmosphere and vaccum/pressure injection. To evaluate the mechanical properties, dumbbell-shaped samples were submitted to tensile test, slab-shaped were submitted to flexure for modulus of elasticity evaluation, and stylus tips and disks were submitted to two-body wear test, evaluating the profile of the samples before and after the test to calculate vertical height loss. Disks were used for microhardness evaluation and microstructural observation. For the biological properties evaluation, SCC9 cells were cultured in D-MEM/HF12 supplemented on the disks and wells without disks were used as control. After 1, 4, 7, 10 and 14-day period, cell proliferation was measured by MTT method. After 7 days, cell viability was evaluated after Trypan blue marking and counting in a hemacytometer. Cell morphology was evaluated in 2, 12 and 24-hour periods examining, in fluorescence microscope under epifluorescence, actin cytoskeleton and cell nuclei, using, respectively, phalloidin and DAPI. The results were submitted to statistical analysis and Ti-5Ta alloy presented ultimate tensile strength lower than the others and modulus of elasticity statistically lower than cp Ti, but no different to the other experimental alloys. In relation to wear resistance, the experimental alloys presented wear significantly lower than cp Ti and the Ti-5Zr alloy presented microhardness greater than other materials. Cell morphology evaluation showed difference in the proportion of cells in the different stages in 2 and 12-hour periods, but not in 24. The cp Ti presented feather-like structure with α phase while Ti-5Zr presented a Widmanstätten structure with α and α´ phases. The Ti-5Ta and Ti-5Ta-5Zr alloys presented α, α´, α´´ and β phases with lamellar and acicular structures, respectively. The results of this study suggest that the studied alloys could be applied in dental prosthesis, once their biological properties were similar to cp Ti in cell proliferation, viability and morphology; and their mechanical properties, like wear resistance, microhardness and ultimate tensile strength were ideal, although the modulus of elasticity can and should be improved.
88

Avaliação fotoelástica de tensões transmitidas por próteses protocolos com barras confeccionadas em diferentes materiais e técnicas / Photoelastic stress analysis of a mandibular implant-supported prosthesis with differrent framework materials

Zaparolli, Danilo 12 December 2014 (has links)
Com o avanço da implantodontia e da estética, novos materiais estão sendo utilizados para substituir partes metálicas de próteses. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas totais de mandíbula em função da variação do material utilizado nas barras e do modo de confecção, através de análise fotoelástica qualitativa. Em um modelo mestre simulando a curvatura da mandíbula foram posicionados 4 implantes de conexão locking taper. A partir deste planejamento foi confeccionada uma barra por CAD/CAM em resina reforçada por fibra que serviu de base para confecção de outras duas barras por CAD/CAM em Ti e CoCr e outra fundida em CoCr, totalizando quatro barras sobre as quais foram confeccionadas próteses totais padronizadas em resina acrílica. Foi analisada a adaptação marginal por meio de microscópio ótico comparador. O modelo fotoelástico foi confeccionado com base no modelo mestre. O ensaio realizado com cargas em oclusão total contra antagonista, mordida anterior, mordida posterior e pontual no extremo do cantilever. Todas as próteses com barras metálicas transmitiram tensões para região cervical dos implantes sendo que a barra de CoCr usinada apresentou o pior padrão de distribuição de tensões e a fundida a pior adaptação / With the recent advancement of implant dentistry and aesthetics new materials are being used to replace metal frameworks of prostheses. This study aimed to compare the stress distributed by mandibular implant-supported prosthesis due to the variation of materials and production techniques of the prosthesis framework by a qualitative photoelastic analysis. In an acrylic model simulating the mandibular curvature, four implants 4.5mm x 6mm with locking taper conection were positioned. From this planning was made a framework of resin reinforced with fiber by CAD/CAM which served as base for manufacturing the two other frameworks in CAD/CAM of Ti and CoCr and cast of CoCr, totaling four frameworks on which standardized denture acrylic resin were prepared. Marginal adaptation was analyzed by optical microscope comparison. The photoelastic model was made based on the master model. The photoelastic test was performed at loads in total occlusion versus antagonist, anterior bite, posterior bite and punctual at the cantilever All prostheses with metal frameworks transmitted stress forces to the cervical region of the implants, and the machined framework of CoCr (G2) showed the worst pattern of stress distribution, and the cast one showed the poorer adjustment (G4). The framework in fiber reinforced resin showed adequate stress distribution and marginal adaptation
89

Avaliação fotoelástica de tensões transmitidas por próteses protocolos com barras confeccionadas em diferentes materiais e técnicas / Photoelastic stress analysis of a mandibular implant-supported prosthesis with differrent framework materials

Danilo Zaparolli 12 December 2014 (has links)
Com o avanço da implantodontia e da estética, novos materiais estão sendo utilizados para substituir partes metálicas de próteses. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas totais de mandíbula em função da variação do material utilizado nas barras e do modo de confecção, através de análise fotoelástica qualitativa. Em um modelo mestre simulando a curvatura da mandíbula foram posicionados 4 implantes de conexão locking taper. A partir deste planejamento foi confeccionada uma barra por CAD/CAM em resina reforçada por fibra que serviu de base para confecção de outras duas barras por CAD/CAM em Ti e CoCr e outra fundida em CoCr, totalizando quatro barras sobre as quais foram confeccionadas próteses totais padronizadas em resina acrílica. Foi analisada a adaptação marginal por meio de microscópio ótico comparador. O modelo fotoelástico foi confeccionado com base no modelo mestre. O ensaio realizado com cargas em oclusão total contra antagonista, mordida anterior, mordida posterior e pontual no extremo do cantilever. Todas as próteses com barras metálicas transmitiram tensões para região cervical dos implantes sendo que a barra de CoCr usinada apresentou o pior padrão de distribuição de tensões e a fundida a pior adaptação / With the recent advancement of implant dentistry and aesthetics new materials are being used to replace metal frameworks of prostheses. This study aimed to compare the stress distributed by mandibular implant-supported prosthesis due to the variation of materials and production techniques of the prosthesis framework by a qualitative photoelastic analysis. In an acrylic model simulating the mandibular curvature, four implants 4.5mm x 6mm with locking taper conection were positioned. From this planning was made a framework of resin reinforced with fiber by CAD/CAM which served as base for manufacturing the two other frameworks in CAD/CAM of Ti and CoCr and cast of CoCr, totaling four frameworks on which standardized denture acrylic resin were prepared. Marginal adaptation was analyzed by optical microscope comparison. The photoelastic model was made based on the master model. The photoelastic test was performed at loads in total occlusion versus antagonist, anterior bite, posterior bite and punctual at the cantilever All prostheses with metal frameworks transmitted stress forces to the cervical region of the implants, and the machined framework of CoCr (G2) showed the worst pattern of stress distribution, and the cast one showed the poorer adjustment (G4). The framework in fiber reinforced resin showed adequate stress distribution and marginal adaptation
90

Avaliação de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias / Evaluation of experimental titanium alloys for prosthodontic frameworks

Adriana Cláudia Lapria Faria Queiroz 29 May 2009 (has links)
A utilização do titânio em odontologia tem aumentado devido suas propriedades mecânicas, biocompatibilidade, resistência à corrosão e baixo peso específico. Entretanto, o uso do titânio em próteses ainda não é rotineiro em virtude de dificuldades no processo de fundição. Uma das maneiras de superar estas dificuldades seria através do desenvolvimento de novas ligas cujo ponto de fusão fosse inferior ao do Ti cp. O objetivo deste estudo foi avaliar as propriedades mecânicas, biológicas e microestrutura de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias, após fundição odontológica, comparando-as ao Ti cp. As ligas experimentais avaliadas foram Ti-5Zr(%p), Ti-5Ta(%p) e Ti-5Ta-5Zr(%p). Os corpos-de-prova foram fundidos por arco voltaico em atmosfera de argônio e injeção por vácuo-pressão. Para avaliação das propriedades mecânicas, corpos-deprova em forma de halteres foram submetidos a ensaios de tração, barras foram submetidas a ensaios de flexão para avaliação do módulo de elasticidade, e hemi-esferas e discos foram submetidos ao teste de desgaste de dois corpos, sendo o perfil das amostras avaliado antes e após o teste para cálculo da perda de altura vertical. Discos foram utilizados para avaliação da microdureza e para caracterização microestrutural. Para avaliação das propriedades biológicas, células SCC9 foram cultivadas em meio de cultura D-MEM/HF12 suplementado sobre discos e poços sem discos foram usados como controle. Após períodos de 1, 4, 7, 10 e 14 dias, foi avaliada a proliferação celular pelo método histoquímico MTT. Aos 7 dias foi avaliada a viabilidade celular após marcação com azul de Trypan e contagem em hemocitômetro. A morfologia celular foi avaliada às 2, 12 e 24 horas através da visualização, em microscópio de fluorescência por epiluminação, do citoesqueleto de actina e dos núcleos, usando, respectivamente, faloidina e DAPI. Os resultados foram submetidos a testes estatísticos e a liga Ti-5Ta apresentou resistência à tração menor que as demais e módulo de elasticidade significativamente menor do que o Ti cp, embora não diferente das demais ligas experimentais. Com relação à resistência à abrasão, as ligas experimentais apresentaram desgaste significativamente menor do que o Ti cp e a liga Ti-5Zr apresentou microdureza significativamente maior do que os demais materiais. Não houve diferença na proliferação e na viabilidade celular entre os materiais. A avaliação da morfologia celular mostrou diferença na proporção de células nos diferentes estágios de desenvolvimento nos períodos de 2 e 12 horas, mas não em 24 horas. O Ti cp apresentou microestrutura do tipo feather-like com fase α, enquanto Ti-5Zr apresentou estrutura do tipo Widmanstätten com fase α e α´. As ligas Ti- 5Ta e Ti-5Ta-5Zr apresentaram as fases α, α´, α´´ e β, com arranjos lamelar e acicular, respectivamente. Os resultados deste estudo sugerem que as ligas estudadas apresentam potencial para aplicação em próteses dentárias, uma vez que suas propriedades biológicas foram semelhantes às do Ti cp, comprovado por proliferação, viabilidade e morfologia celular; e suas propriedades mecânicas, como resistência à abrasão, microdureza e resistência à tração foram satisfatórias, ainda que o módulo de elasticidade possa e deva ser melhorado. / The use of titanium in dentistry have increased due to its mechanical properties, biocompatibility, corrosion resistance and density. However, titanium has not been routinely used because of the difficulties related to casting technique. One of the options to solve these difficulties would be to develop new titanium alloys whose melting point was lower than cp Ti. So, the aim of this study was to evaluate the mechanical and biological properties and microstructure of experimental titanium alloys for prosthesis frameworks, after dental casting, comparing to cp Ti. The experimental alloys evaluated were Ti-5Zr(%w), Ti-5Ta(%w) and Ti-5Ta-5Zr(%w). The samples were cast by voltaic arc in argon atmosphere and vaccum/pressure injection. To evaluate the mechanical properties, dumbbell-shaped samples were submitted to tensile test, slab-shaped were submitted to flexure for modulus of elasticity evaluation, and stylus tips and disks were submitted to two-body wear test, evaluating the profile of the samples before and after the test to calculate vertical height loss. Disks were used for microhardness evaluation and microstructural observation. For the biological properties evaluation, SCC9 cells were cultured in D-MEM/HF12 supplemented on the disks and wells without disks were used as control. After 1, 4, 7, 10 and 14-day period, cell proliferation was measured by MTT method. After 7 days, cell viability was evaluated after Trypan blue marking and counting in a hemacytometer. Cell morphology was evaluated in 2, 12 and 24-hour periods examining, in fluorescence microscope under epifluorescence, actin cytoskeleton and cell nuclei, using, respectively, phalloidin and DAPI. The results were submitted to statistical analysis and Ti-5Ta alloy presented ultimate tensile strength lower than the others and modulus of elasticity statistically lower than cp Ti, but no different to the other experimental alloys. In relation to wear resistance, the experimental alloys presented wear significantly lower than cp Ti and the Ti-5Zr alloy presented microhardness greater than other materials. Cell morphology evaluation showed difference in the proportion of cells in the different stages in 2 and 12-hour periods, but not in 24. The cp Ti presented feather-like structure with α phase while Ti-5Zr presented a Widmanstätten structure with α and α´ phases. The Ti-5Ta and Ti-5Ta-5Zr alloys presented α, α´, α´´ and β phases with lamellar and acicular structures, respectively. The results of this study suggest that the studied alloys could be applied in dental prosthesis, once their biological properties were similar to cp Ti in cell proliferation, viability and morphology; and their mechanical properties, like wear resistance, microhardness and ultimate tensile strength were ideal, although the modulus of elasticity can and should be improved.

Page generated in 0.0808 seconds