• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 52
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 122
  • 122
  • 39
  • 37
  • 32
  • 19
  • 16
  • 15
  • 15
  • 14
  • 13
  • 13
  • 13
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação in vitro da translucidez de dois sistemas cerâmicos metal-free : In-Ceram x Empress 2 /

Augusto, Jean Carlo Duarte. January 2004 (has links)
Resumo: Os sistemas cerâmicos metal-free são materiais odontológicos restauradores indiretos com excelentes propriedades ópticas, mecânicas e biológicas. As indicações destes materiais têm uma relevância clínica fundamental nos dias atuais, visto que, as expectativas dos pacientes por excelentes resultados estéticos são cada vez maiores. Conhecer amplamente as propriedades destes materiais é importante na evolução da área odontológica. O objetivo deste trabalho foi realizar, in vitro, uma comparação da propriedade óptica de translucidez de dois sistemas cerâmicos metal-free amplamente utilizados nos consultórios odontológicos (In-Ceram e Empress 2) comparando grupos de estudo que representassem quadros próximos às situações clínicas, produzindo amostras dos materiais estudados na espessura em que são indicados pelos fabricantes, ou seja, 0,5 mm para a infra-estrutura ou coping do In-Ceram, e 0,8 mm para a infra-estrutura do Empress 2. Foi produzido um grupo experimental com o material de Empress 2 na espessura de 0,5 mm, para ter-se um parâmetro de comparação dos dois materiais na mesma espessura. Nesta fase, todos os corpos de prova foram submetidos às leituras de translucidez, com o emprego do aparelho Jouan. Os corpos de prova foram, em uma etapa seguinte, cobertos pela cerâmica de estratificação para compararmos a situação clínica final de uma restauração indireta. Produziram-se corpos de prova com a espessura de 1,5 mm, e nova leitura da translucidez foi realizada. Esses corpos de prova receberam então o tratamento de glazeamento na face em que haviam sido cobertos com a cerâmica de estratificação, e foi realizada a última leitura da translucidez destes materiais. Os resultados, segundo a metodologia empregada, mostraram que, o Sistema Empress 2 apresenta índices translucidez superiores ao In-Ceram. Quando comparados os materiais de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: All-ceramic systems are indirect restoring materials with excellent optical, mechanical and biological properties. The use of those materials have a fundamental clinical relevance nowadays, since the patients expectations for best esthetical results are increasing. Deep knowledge of these materials properties is very important to odontology area evolution. The objective of this work was to make an in vitro comparison on translucency optical property of two all-ceramic systems often used at dental offices (In-Ceram and Empress 2) when searching for excellence on esthetical results. This work tried to compare studying groups that represented characteristics approximate to clinical situations, producing samples of studied materials at thickness recommended by manufacturer's, that is, 0,5 mm for the core materials or coping of In-Ceram, and 0,8 mm for the Empress 2. It was produced an experimental group with the Empress 2 material at thickness of 0,5 mm, in order to provide a comparison parameter for both materials at the same thickness. At this phase, all the disc specimens were submitted to quantitative measurement of translucency, using Jouan equipment. In the next phase, the disc specimens were veneered with stratification ceramic so we could compare the final clinical situation of an indirect restoration. Disc specimens were produced with thickness of 1,5 mm, and a new measurement of translucency was made. These samples then received a glazing cycle on the side that were veneered with stratification ceramic, and finally we made the last measurement of translucency on these materials. The results, according to adopted methodology, showed that the Empress 2 System presents greater translucency than In-Ceram System. When the core materials were compared, one can establishes that: translucency index of Empress 2 (0,5 mm) > Empress 2 (0,8 mm)... (Complete abstract, click electronic address below) / Orientador: Osmir Batista de Oliveira Júnior / Coorientador: Vanderlei Salvador Bagnato / Banca: José Roberto Cury Saad / Banca: Luis Anselmo Mariotto / Mestre
92

Resistência à flexão, resistência à tração diametral e dureza de sistemas cerâmicos para infra-estrutura /

Schalch, Max von. January 2003 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Renata Garcia Fonseca / Banca: Alma Blásida Concepción Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi comparar a resistência à flexão, a resistência à tração diametral e a dureza do material de infra-estrutura dos sistemas cerâmicos IPS-Empress 2/Ivoclar (dissilicato de lítio, processado por injeção) e In-Ceram Zirconia/Vita (óxidos de alumínio e zircônio, processados por dupla sinterização). Foram confeccionadas dez amostras de cada material para o ensaio de flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System - EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada cerâmica foram incluídos em resina acrílica autopolimerizável JET (Artigos Odontológicos Clássico, Brasil), polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Os resultados mostraram maior resistência à flexão do material In-Ceram Zirconia (439,88MPa) em relação ao IPS-Empress 2 (226,13MPa). Entretanto, observou-se maior resistência à tração diametral do IPS-Empress 2 (175,08MPa) em relação ao In-Ceram Zirconia (150,47MPa). Para a dureza Vickers, o material In-Ceram Zirconia (972,0VHN) mostrou-se superior em relação ao IPS-Empress 2 (488,33VHN). / Abstract: The aim of this study was to compare flexural strength, diametral tensile strength and hardness of infra-structure ceramic systems IPS-Empress 2/Ivoclar (litium dissilicate, heat-pressed) and In-Ceram Zirconia/Vita (aluminum and zirconium oxides, Slip casting). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter; 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. In flexural test, In-Ceram Zirconia (439.88MPa) showed greater strength than IPS-Empress 2 (226.13MPa). However, the IPS-Empress 2 (175.08MPa) showed greater diametral strength than In-Ceram Zirconia (150.47MPa). For hardness, the In-Ceram Zirconia (972.0VHN) showed greater than IPS-Empress 2 (488.33VHN). / Mestre
93

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Jesuina Lamartine Nogueira Araujo 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
94

Morfologia da superficie e resistencia da união de ceramica IPS Empress Esthetic submetida a diferentes tratamentos / Bond strenght and surface/interface morphology of luting polymers and glass ceramic etched for different periods

Naves, Lucas Zago, 1981- 13 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Carlos Jose Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:11:57Z (GMT). No. of bitstreams: 1 Naves_LucasZago_M.pdf: 3732245 bytes, checksum: f19061d71b96dbce2d54cda8b37f2ba9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a morfologia de superfície e resistência de união ao microcisalhamento entre a cerâmica reforçada por leucita IPS Empress Esthetic (Ivoclar- Vivadent) e o cimento resinoso Variolink II (Ivoclar-Vivadent), em diferentes tempos de condicionamento da cerâmica, com e sem aplicação do adesivo após o uso do silano. Setenta e dois discos cerâmicos (6mm de diâmetro x 2mm de espessura) foram confeccionados, embutidos em resina e divididos em 12 grupos (n=6), definidos pelo tempo condicionamento com ácido fluorídrico 10% e aplicação ou não de adesivo após o uso do silano: G1 e G7 - 10s de condicionamento ácido, G2 e G8 - 20 s; G3 e G9 - 40 s; G4 e G10 - 60 s; G5 e G11 - 120 s e G6 e G12 - 60 + 60s. O silano foi aplicado em todos os grupos e metade dos grupos (de G7 a G12) receberam uma camada do adesivo (Scotchbond MP - 3M/ESPE). Molde de elastômero com dois orifícios cilíndricos (1,2mm de diâmetro x 2mm de altura) foi adaptado sobre a superfície da cerâmica para a construção de dois cilindros por amostra, totalizando 12 cilindros por grupo. Para tal, os orifícios foram preenchidos com o cimento resinoso (Variolink II), fotoativados por 40 s e submetidos ao ensaio de resistência de união ao microcisalhamento a velocidade de 0,5mm/min. e o padrão de fratura foi analisado. Os dados foram submetidos à Análise de Variância e ao teste de Student-Newman-Keul (p<0,05). A topografia e a interface de união foram avaliadas em MEV. A resistência de união ao microcisalhamento (MPa) foi 19,4±3,5 (G1), 22,3±5,1 (G2), 22,2±3,2 (G3), 17,8±2,1 (G4), 15,3±3,0 (G5), 14,3±1,8 (G6) para os grupos tratados com silano, e 17,4±4,8 (G7), 21,3±2,1 (G8), 21,1±2,3 (G9), 24,7±5,8 (G10), 20,4±2,2 (G11) e 18,5±4,6 (G12) para os grupos tratados com silano + adesivo. Houve redução de falhas adesivas e aumento das mistas com o aumento do tempo de condicionamento para os grupos tratados com silano e equilíbrio da falhas adesivas e mistas para os grupos tratados com silano + adesivo, exceto para os grupos G11 e G12 onde houve predominância de falhas mistas. Pouca alteração na topografia de superfície foi detectada nas amostras condicionadas por 10s, canais apresentando sulcos profundos puderam ser notados em praticamente toda a extensão das superfícies cerâmicas recondicionadas (60+60s - G6 e G12). Espaços não-preenchidos ao longo da interface cerâmica-cimento resinoso foram detectados em intensidade crescente a partir de 60s de condicionamento, quando apenas o silano foi aplicado, enquanto um preenchimento homogêneo, caracterizado por íntimo contato com a cerâmica pode ser percebido quando o adesivo foi utilizado, exceto para o grupo recondicionado - G12. / Abstract: This study evaluated the influence of etching times on surface/interface morphology and micro-shear bond strength to Empress Esthetic leucite-reinforced glass ceramic (Ivoclar-Vivadent), with or without application of an unfilled resin after silane. Ceramic discs were divided into 12 groups (n = 6), defined by the etching time with 10% hydrofluoric acid: G1 and G7 - etching for 10s, G2 and G8 - 20 s; G3 and G9 - 40 s; G4 and G10 - 60 s; G5 and G11 - 120 s and G6 and G12 - 60 + 60s. Half of the groups (G7 to G12) received a layer of unfilled resin (Scotchbond MP/ 3M ESPE) after silane coupling. Micro-shear bonding test using Variolink II resin cement (Ivoclar-Vivadent) was performed, and data submitted to two-way ANOVA and Student-Newman-Keuls' test (p < 0.05). Evaluation of the etching pattern and bonding interfaces was conducted by Scanning Electron Microscopic (SEM). Means micro-shear bond strengths (MPa) were 19.4±3.5 (G1), 22.3±5.1 (G2), 22.2±3.2 (G3), 17.8±2.1 (G4), 15.3±3.0 (G5), 14.3±1.8 (G6) for groups treated with silane, and 17.4±4.8 (G7), 21.3±2.1 (G8), 21.1±2.3 (G9), 24.7±5.8 (G10), 20.4±2.2 (G11) e 18.5±4.6 (G12) for groups treated with silane and unfilled resin. Poor etching topography was detected on 10s etched surfaces, whereas fissures forming deep grooved channels were extensively observed in 120s and 60+60s ceramics surfaces. Unfilled spaces underlying the ceramic-resin cement interface were detected when only silane was applied. Fully completion of the irregularities on 60s and 120s samples were detected using the unfilled resin, although this material was unable to completely fill the irregularities on 60+60s (G12) ceramic. When only silane was applied, the 60s and the groups etched for longer periods (120 and 60+60s - G5 and G6) showed lower bond strengths, but when both silane and unfilled resin were applied, all etching times generally showed similar values. The etching protocol influenced the surface/interface topography and bond strength to ceramic. The application of unfilled resin was able to infiltrate all unfilled spaces beneath the ceramic-resin cement interface detected when only silane was applied, except on the re-etched (60+60s - G12) ceramic. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
95

A avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infraestrutura e da aplicação de carga em cristas marginais / Evaluation of reliability and failure modes of ceramic crown systems depending on framework design and marginal ridge load application

Vinícius Pavesi Fardin 29 May 2013 (has links)
As excelentes propriedades mecânicas da zircônia fazem com que ela seja o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, os problemas relacionados à fratura ainda persistem. A falta de suporte das infraestruturas às cerâmicas de revestimento é indicada como uma possível causa. O presente estudo visou avaliar através de testes laboratoriais se as infraestruturas metálicas e cerâmicas com o desenho convencional ou modificado apresentam diferença estatisticamente significante quanto à redução de complicações mecânicas, como fraturas e trincas na cerâmica de revestimento ao receberem cargas axiais nas cristas marginais de coroas de um primeiro molar inferior, por meio das seguintes hipóteses nulas: 1) a resposta à fadiga nas cristas marginais não aumentará a presença de danos nas coroas; 2) o desenho da I.E. não modificará a presença de danos nas coroas, independente do material utilizado. Quarenta coroas unitárias foram confeccionadas sobre preparos padronizados e divididos em 4 grupos: grupo I (infraestrutura convencional de Cobalto-Cromo); grupo II (infraestrutura modificada de Cobalto-Cromo); grupo III (infraestrutura convencional de Zircônia - IPS Emax ZirCAD); grupo IV (infraestrutura modificada de Zircônia - IPS Emax ZirCAD). Estas coroas foram submetidas ao teste de resistência à fadiga por meio da ciclagem dinâmica em água (106 ciclos ou até a fratura com carga variando de 30-300 N). Aplicou-se a carga inicial com o endentador cerâmico de dissilicato de lítio (IPS Emax Press) na crista marginal mesial, e após o término do ciclo, na distal, alternativamente. A ciclagem foi interrompida em intervalos de 125 mil ciclos a procura de danos com auxílio de estereomicroscopia. Ao final, as coroas fraturadas foram submetidas à microscopia eletrônica de varredura e as não fraturadas foram incluídas em resina epóxi e polidas sequencialmente para a análise dos danos. Cada corpo de prova recebeu escores de acordo com o tipo de falha apresentado. Utilizou-se o teste Kruskal-Wallis para verificar diferença estatística entre os grupos e o teste de Dunn para comparações múltiplas entre os grupos. Os resultados mostraram que há diferença estatisticamente significante entre os grupos, entretanto não houve diferença entre os grupos do mesmo sistema cerâmico. Concluiu-se que a hipótese 1 foi aceita e a 2 rejeitada. / The excellent mechanical properties of zirconia make it to be the material of choice for ceramic crowns and posterior fixed prostheses. However, problems still exist related to the chippings. The lack of framework support to ceramic veneer is indicated as a possible cause. This study aimed to evaluate through laboratory tests if metallic and ceramic framework with conventional or modified design show statistical difference in reducing mechanical complications, such as chipping or fracture of the ceramic veneer on receiving axial loads in marginal ridges of the first molar inferior crowns through the following null hypotheses: 1) the response to fatigue in marginal ridges will not increase the presence of damage to the crowns; 2) framework`s design will not modify the presence of damage to the crowns, regardless of the material used. Forty crowns were manufactured on standardized preparations and divided into four groups: group I (conventional framework Cobalt-Chromium), group II (modified framework Cobalt-chromium), group III (conventional framework Zirconia - ZirCAD IPS Emax) and group IV (modified framework Zirconia - IPS Emax ZirCAD). These crowns were subjected to cyclic loading in a fatigue machine and submerged in water (1.000.000 cycles or until the fracture - load range at 30-300 N). The initial load was applied on the mesial marginal ridge with indenter ceramic Lithium disilicate (IPS Emax Press), and after the end of the cycle, the distal alternatively. The cycling was interrupted at a prescribed number of loading cycles (125.000) and crowns were inspected for damage accumulation under a stereomicroscope. In the end, fractured crowns were submitted to scanning electron microscopy and crowns without fractures were embedded in epoxy resin and sequentially polished for the analysis of the damage. Each sample received scores according to the type of failure presented. Statistical analysis was carried out with Kruskal-Wallis test and multiple conparisons between groups were carried out with Dunn wed significant differences between groups, however there was no difference between the groups of the same ceramic systems. It was concluded that the first hypothesis was accepted and the second hypothesis was rejected.
96

\"Estudo espectrofotométrico comparativo da estabilidade de cor de três porcelanas dentais após consecutivas queimas\" / Comparative spectrophotometric study of the color stability of three dental porcelains after repeated firings

Marcelo Weber 25 September 2006 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de três marcas comerciais de porcelanas aluminizadas durante seu processo de queima. Para o experimento foram confeccionados 30 corpos de prova em forma de disco com 2mm de espessura e 10mm de circunferência, sendo 10 da marca ALLCeram, 10 da marca Noritake Cerabien CZR e 10 da marca Vita VM7. As amostras foram queimadas 10 vezes. As leituras de cor foram feitas em espectrofotômetro de reflexão nos seguintes intervalos: após a 1ª queima, após a 3ª queima, após a 5ª queima e após a 10ª queima. As curvas de reflexão foram convertidas em valores LAB e a diferença de cor foi medida através do método CIELAB (FE). Os resultados obtidos demonstraram que existe variação de cor e que esta variação depende do número de queimas realizadas e da marca comercial utilizada. / The purpose of this investigation was to quantify in CIE FE units the differences in color produced by multiple firing of three allceramic systems. For this study 30 samples were fabricated of 3 brands: AllCeram, Noritake Cerabien CZR and Vita VM7. A spectrophotometer was used for reflectance measurement of color after 1 firing, 3 firings, 5 firings and 10 firings. The results were converted in CIELAB units. Color differences, FE, were calculated in the CIE color space. Color differences as a result of multiple firings depended on the number of firings and the brand tested.
97

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Ricardo Sgura 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.
98

Comparison of the Colors of Dental Porcelain using Conventional and Press-on-Metal Ceramic Technologies for Four Substrate Metals

Khmaj, Abdulfatah B.EM 27 June 2012 (has links)
No description available.
99

Comparison of Metal-Ceramic Bond Strengths of Four Noble Alloys using Press-on-Metal (PoM) and Conventional Layering Techniques

Khmaj, Mofida R.ajaili 26 June 2012 (has links)
No description available.
100

Hållfasthet och krympning utifrån olika modelleringsvätskor till porslin

Cwiek, Aleksandra January 2018 (has links)
SyfteFöreliggande studie syftar till att närmare undersöka böjhållfastheten och krympningen på två olika porsliner blandade med respektive vätska av samma fabrikat, destillerat vatten eller universalvätskor.HypotesVätskan med lägst densitet kommer resultera i högre hållfasthetsvärden, minst krympning och porositet på grund av vätskans innehåll som bidrar till högre vätning av porslinet och därmed ger bättre tätpackning.Metod Två olika dentala porsliner blandades med fyra olika modelleringsvätskor, fabrikantens vätska, två universella vätskor och destillerat vatten. 10 provkroppar framställdes per respektive grupp, vilket gav totalt 80 provkroppar fördelade i 8 grupper. Alla provkroppar mättes, genomgick ett 4-punkts böjhållfasthetstest och en provkropp per grupp blev slumpmässigt vald till inspektion av porositet med ett mikroskop. Slutligen fördes det en statistisk jämförelse av böjhållfastheten och krympningen mellan grupperna, samt dokumentation av mikrostrukturen av de utvalda provkropparna.Resultat Provkropparna blandade med destillerat vatten visar signifikant högre böjhållfashetsvärden jämfört med en provgrupp blandad med universell modelleringsvätska. Provkropparna blandade med destillerat vatten visade även signifikant högre krympning, medan provkropparna med tillverkarens vätska visade minsta krympning.Slutsats I föreliggande studie visade destillerat vatten att vara mest pålitligt val vad det gäller hög böjhållfasthet. Fabrikantens vätska (GC Initial MC) fick minst signifikant krympning. Däremot finns det otillräcklig evidens som bifaller kopplingen mellan modelleringsvätskans densitet och dess påverkan på böjhållfashetsvärden samt krympning / Purpose The present study aims to investigate the flexural strength and shrinkage of two types of porcelain mixed with the manufacturer's modelling liquid as well as distilled water and universal liquids.Hypothesis The liquid with lowest density will result in higher strength values, lower shrinkage and porosity due to the liquids content that contributes to higher wetting of the powder, thus providing better sealing.Method Two different porcelain were mixed with four different liquids, the manufacturer’s liquid, two universal liquids and distilled water. Ten specimens were prepared per respective group, giving a total of 80. All specimens underwent measuring, flexural strength test and one specimen per group was selected for surface analysis with a microscope inspection. Finally, there was a statistical comparison of the flexural strength between the groups, as well as documentation with photographs of the microstructure of the selected specimens.Results The specimens mixed with distilled water show significantly higher flexural strength values compared to one specimen group mixed with universal modelling liquid. Specimen mixed with distilled water showed significant higher shrinkage, whereas the specimens with the manufacturer's liquid showed least shrinkage.Conclusion Distillated water showed to be most reliable in terms of high flexural strength. The manufacturer’s liquid (GC Initial MC) showed least significant shrinkage. On the other hand, there is insufficient evidence that proves the connection between the density in modeling liquid and its influence on flexural strength values as well as shrinkage

Page generated in 0.0555 seconds