31 |
A three-dimensional photoelastic stress analysis of the mandibular staple bone plate a thesis submitted in partial fulfillment ... denture prosthodontics ... /Riedy, Stephen J. January 1984 (has links)
Thesis (M.S.)--University of Michigan, 1984.
|
32 |
Photoelastic stress analysis of the bone supporting a dental endosteal implant thesis submitted in partial fulfillment ... dental materials ... /Yapp, Ronald A. January 1977 (has links)
Thesis (M.S.)--University of Michigan, 1977.
|
33 |
Photoeleastic stress analysis of four different prefabricated posts for endodontically treated teeth a thesis submitted in partial fulfillment ... restorative dentistry, operative /Thorsteinsson, Thorsteinn Sch. January 1990 (has links)
Thesis (M.S.)--University of Michigan, 1990.
|
34 |
Two dimensional photoelastic stress analysis of nickel titanium and stainless steel finger spreaders during lateral condensation a thesis submitted in partial fulfillment ... for the Degree of Master of Science in Endodontics ... /Dwan, Jeffrey John. January 1997 (has links)
Thesis (M.S.)--University of Michigan, 1997. / Includes bibliographical references.
|
35 |
Análise fotoelástica da distribuição de tensões nos segundos molares inferiores geradas por diferentes mecânicas de verticalização / Photoelastic analysis of stress distribution in lower second molars caused by several uprighting mechanicsAndre Felipe Abrão 06 June 2014 (has links)
A verticalização de molares inferiores é indicada quando ocorre inclinação mesial dos segundos molares, atribuídas à ausência do primeiro molar. Existem inúmeras metodologias para realização de tal movimento. O objetivo do estudo foi analisar e comparar in vitro, por meio de fotoelasticidade, a distribuição de tensões nos segundos molares inferiores geradas por diferentes métodos de verticalização. Foram avaliados quatro modelos com as seguintes mecânicas: mini-implante, cantiléver, mola em T e mola aberta. As regiões do segundo molar selecionadas para avaliação foram: cervical da raiz mesial, apical da raiz mesial, cervical da raiz distal e apical da raiz distal. A resultante das forças aplicadas foi aferida por meio da quantificação das franjas isocromáticas. Os valores de franjas foram descritos com uso de média e desvio padrão e verificada a concordância/reprodutibilidade entre as avaliações com uso do coeficiente de correlação intraclasse com os respectivos intervalos com 95% de confiança e calculadas as medidas de repetibilidade. Os diferentes tipos de mecânicas foram comparados com uso de teste não paramétrico e quando o teste apresentou significância estatística foram realizadas comparações múltiplas não paramétricas para medidas pareadas com o intuito de verificar entre quais tipos de mecânicas ocorreram diferenças nas ordens das franjas. Os valores diferiram estatisticamente entre os tipos de mecânica utilizados (p < 0,05), exceto na região cervical distal, onde apresentaram-se estatisticamente iguais nos quatro tipos de mecânica (p = 0,112). Na técnica utilizando mini-implante, as maiores tensões foram encontradas na região cervical distal, seguidas de apical da raiz mesial e apical da raiz distal. Na região cervical mesial não foram detectadas tensões. Utilizando o cantiléver, as maiores tensões localizaram-se na região cervical mesial, seguidas de apical da raiz mesial e região cervical distal. Não foram detectadas tensões na apical da raiz distal. Na mola em T, as maiores tensões foram observadas na apical da raiz mesial, seguidas de região cervical da raiz mesial, apical da raiz distal e região cervical distal. Na mola aberta, as maiores tensões foram constatadas na apical da raiz mesial, seguidas de região cervical mesial, região cervical distal e apical da raiz distal. Ao compararem-se as técnicas, foi possível concluir que o mini-implante é a técnica que apresentou as menores tensões e o cantiléver as maiores tensões nas regiões estudadas. / Lower molars uprighting is indicated when mesial inclination of second molars occurs due to the lack of first molars. There are many methodologies to perform such movement. The goal of this research study was to in vitro analyze and compare, by means of photoelasticity, the strain distribution in lower second molars caused by several uprighting methods. Four models with the following mechanics have been evaluated: miniscrews, cantilever, T- loop spring and open coil spring. The second molar areas selected for the evaluation were the following ones: mesial-cervical area, apical area of the mesial root, distal-cervical and apical areas of the distal root. The resultant of forces applied was measured by quantifying isochromatic fringes. The fringe values were described using the mean and the standard deviation values and the agreement/reproducibility among the assessments were verified applying the intraclass correlation coefficient in the respective intervals with 95% confidence. Repeatability measures were calculated. The different types of mechanics were compared applying the nonparametric test and, when the test showed statistical significance, nonparametric multiple comparisons were carried out for paired measurements, aiming at checking in which mechanics fringe differences occur. Values statistically differed among the types of mechanics applied (p < 0.05), except in the distal-cervical area, in which the values were statistically the same for the four types of mechanics (p = 0.112). In the technique using miniscrews, the highest strain values were found in the distal-cervical area, followed by the apical area of the mesial root and the apical area of the distal root. No strain was found in the mesialcervical area. With the cantilever, the highest strains were found in the mesialcervical area, followed by the apical area of the mesial root and the distal-cervical area. No strain was found in the apical area of the distal root. In the T-loop spring, the highest strains were found in the apical area of the mesial root, followed by the cervical area of the mesial root, the apical area of the distal root and the distalcervical area. With the open coil spring, the highest strains were found in the apical area of the mesial root, followed by the mesial-cervical, the distal-cervical and the apical areas of the distal root. When comparing the techniques, it was concluded that the miniscrew showed the lowest stresses and the cantilever the highest stresses in the study regions.
|
36 |
Efeito da ciclagem mecânica na resistência de união à dentina humana de uma resina composta associada a dois sistemas adesivos / Effect of mechanical cycling on the human dentin bond strength, of a composite associated to two adhesive systemsBodi, Lucia Helena Vieira Diniz 24 March 2010 (has links)
Diante da grande preocupação atual por sorrisos que também embelezem um rosto, a escolha por materiais estéticos impulsiona pesquisas, que tem como objetivo não só melhorar a qualidade, mas, facilitar o uso desses materiais pelos profissionais. Assim, a proposta desse trabalho foi avaliar a influência da ciclagem mecânica na resistência de união de uma resina composta associada a um sistema adesivo convencional e um autocondicionante à dentina humana hígida por meio de teste de microtração. Para o estudo, foram utilizados 40 terceiros molares humanos hígidos, nos quais as faces oclusais foram lixadas até a obtenção de uma superfície plana com exposição do tecido dentinário. Os dentes foram divididos, aleatoriamente, em quatro grupos (n=10) de acordo com o sistema adesivo utilizado e a realização ou não da ciclagem mecânica: G1 Sistema adesivo Adper Single Bond 2 sem ciclagem mecânica (SB); G2 Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CF); G3 - Sistema adesivo Adper Single Bond 2 com ciclagem mecânica (SBC); G4 - Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CFC). Blocos de resina composta foram confeccionados nas superfícies dentinárias após aplicação do sistema adesivo correspondente. Após esse passo, os espécimes dos grupos 3 e 4 passaram por ciclagem mecânica enquanto o restante ficou armazenado em água destilada, mantidos em estufa à 37ºC até o momento do recorte dos espécimes para o teste de microtração. Os corpos de prova foram seccionados em planos perpendiculares à área de união para obtenção de espécimes com área de secção transversal aproximada de 1,0 mm², que foram tracionados, em máquina de ensaios universal, a velocidade de 0,5mm/min. Os resultados de resistência de união foram analisados usando o teste estatístico análise de variância e os modos de fratura foram avaliados em lupa estereoscópica (25X). Não foram encontradas diferenças estatísticas entre os grupos (p<0,05). Pôde-se concluir que não houve influência da ciclagem mecânica nos valores de resistência de união da resina composta associada a ambos os sistemas adesivos utilizados. / In face of an increasing concern about a smile profile that also enhances the overall facial appearance (esthetics), the choosing for more esthetic restorative materials, set in motion researches that have as objective not only the improvement of the quality, but also the easiness of use of these materials by clinicians. The purpose of this in vitro study was to evaluate, by means of a micro tensile test, the influence of the mechanical cycling, on the bond strength of a resin composite, associated to a total etch and a self etching adhesive systems, on the surfaces of sound human dentin. For this study, forty freshly extracted third molars had their oclusal surfaces grounded parallel-flat, until the dentin surfaces were completely exposed. The teeth were randomly divided in four groups (n=10) in accordance with the type of adhesive system and the mechanical cycling treatment, being: G1 Adper Single Bond 2 without mechanical cycling (SB); G2 Clearfill SE Bond without mechanical cycling (CF); G3 - Adper Single Bond 2 with mechanical cycling (SBC); G4 - Clearfill SE Bond without mechanical cycling (CFC).Following the application of the adhesive systems, regarding to each experimental condition, blocks of Z-250 composite were built, on the dentinal surfaces. After this step, the G3 and G4 specimens were submitted to the mechanical cycling test, while the G1 and G2 specimens were kept stored in distilled water at 37°C, until the moment of sectioning for the microtensile test. The specimens were seccionated perpendicularly to their adhesive area to obtain beam shaped specimens with approximate cross-section area of 0.8mm2, which were readily submitted to the microtensile test in a universal test machine with a crosshead speed of 0.5mm/min. The fracture modes were evaluated by means of a stereoscopic microscope (25x). There were no significant statistical differences founded in the bond strength values among the tested groups.
|
37 |
INFLUÊNCIA DA INCORPORAÇÃO DE UM PLASTIFICANTE E UM POLIETILENO DE ALTO PESO MOLECULAR NAS PROPRIEDADES DE UMA RESINA EXPERIMENTAL E DIMINUIÇÃO DO ESTRESSE DE CONTRAÇÃO / Influence of the incorporation of a plasticizer and high molecular weight polyethylene on the properties of an experimental resin and shrinkage stress decrease.Dominguez, John Alexis 13 August 2015 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1
John Alexis Domingues.pdf: 1971333 bytes, checksum: 6d76db539da045af70dd08f004b5c7c8 (MD5)
Previous issue date: 2015-08-13 / The objectives of this study were: 1) to evaluate the degree of conversion, shrinkage stress, flexural and compressive strength of an experimental resin with a lactic polyacid and castor oil; 2) to evaluate the cytotoxicity of an experimental resin with a lactic polyacid, and castor oil; 3) evaluate, degree of conversion,
shrinkage stress, flexural and compressive strength an experimental resin with addition of a high molecular weight polyethylene; 4) to assess the cytotoxicity of an experimental resin with addition of a high molecular weight polyethylene.
Initially, it was synthesized a poly (lactic acid) (PLA) via a polycondensation process. After 24 hours, the castor oil (OR) was incorporated by an esterification process with N, N-Dicyclonecylcarbodimide and 99% 4-Dimethylamino-Pyridine
in 40 mL of tetrahydrofuran. After this, the blend was characterized by X-ray diffraction (XRPD), Raman spectroscopy, scanning electron microscopy (SEM) and shrinkage stress, where was proven the incorporation of PLA + OR in the experimental composite resin. In the third chapter, PLA + OR were manipulated
in two concentrations (1.5% and 3%) in an experimental composite: (2,2 bis [4- (2-hydroxy-3-metacrilatoxypropoxy) phenol] (BisGMA) Triethylene glycol dimethacrylate (TEGDMA), camphorquinone (CQ), N, N-dimethylaminoethyl
methacrylate (DEMA-EMA), butylated hydroxytoluene (BHT), silanated barium borosilicate glass, and the tests of degree of conversion, compressive and flexural strength and shrinkage stress were made. The cytotoxicity assay was done; a suspension of 3 x 103 cells/mL of culture medium was prepared. For this, the cells were detached from the bottom of the bottle by the addition of trypsin with EDTA, after incubation in 5% CO2 with 3 mL Eagle's medium supplemented culture. After 24 h incubation period, the culture medium was removed and 200
uL of a solution of culture medium and methylltetrazolium salt (MTT). Subsequently, the analysis of mitochondrial activity was performed in a spectrophotometer (Biotek EL 800, Biotek, Winooski, VT, USA) with a 10 wavelength of 570 nm. The data from each test were analyzed by one-way ANOVA. No significant differences were found (p <0.005) in compressive and
degree of conversion tests, and significant differences in shrinkage stress where obtained, up to 69% decrease. and flexion, statistically significant . In the fourth chapter, it was incorporated a high molecular weight polyethylene and
polypropiylene, in the experimental resin proposed in chapter two, at two concentrations (1.5% and 3%), and tested by degree of conversion, compressive and flexural strength and shrinkage stress. The data from each test were analyzed by one way ANOVA, finding no significant difference (p> 0.005) in
degree of conversion, compressive and flexural strength, and the contraction stress showed a significant reduction of up to 40%. Conclusion: PLA + castor oil and the high molecular weight polyethylene decreases the shrinkage stress and properties like flexural and compressive strength and degree of conversion were not influenced. / Os objetivos deste estudo foram: 1) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com um poliácido lático e óleo de rícino; 2) avaliar a citotoxicidade de uma resina
experimental com um poliácido lático e óleo de rícino; 3) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com adição de um polietileno de alto peso molecular e 4) avaliar a citotoxicidade de uma resina experimental com adição de um polietileno de alto peso molecular. Previamente realizou-se a síntese de um Poli-ácido lático (PLA) por meio de um processo de policondensação. Após 24 horas, foi incorporado o óleo de rícino (OR) por meio de um processo de esterificação junto
a N,N-Diciclonecilcarbodimida e 4-Dimetilamino-Piridina a 99% em 40 mL de tetrahidrofeurano. Em seguida, o conjunto foi caracterizado por difração de espectroscopia Raman, microscopia eletrônica de varredura (MEV) e estresse
de contração, onde foi comprovada a incorporação do PLA+OR numa resina composta experimental. No terceiro capítulo foi feita a incorporação do PLA+OR em duas concentrações (1,5% e 3%) numa resina composta experimental: (2,2 bis[4-(2-hidroxi-3-metacrilatoxipropoxi)fenol](BisGMA), Trietilglicoldimetacrilato
(TEGDMA), canforoquinona (CQ), N,N– dimetilaminoetil metacrilato (DMAEMA), hidroxitolueno butilado (BHT), vidro de borossilicato de bário silanizado e foram realizados os testes de flexão, compressão, grau de conversão e estresse
de contração. Foi feito o teste de citotoxicidade, uma suspensão de 3 x 103 células/mL de meio de cultura foi preparada. Para isso, as células foram descoladas do fundo da garrafa por meio da adição de tripsina com EDTA, após incubação em estufa com 5% de CO2 e 3 mL de meio de cultura Eagle suplementado. Após o período de incubação de 24 h, o meio de cultura foi
removido e 200 μL de uma solução de meio de cultura e sal metiltetrazólio (MTT).Posteriormente, a análise da atividade mitocondrial foi realizada em espectrofotômetro (Biotek EL 800, Biotek, Winooski, VT, EUA) com comprimento
de onda de 570 nm. Os dados obtidos de cada teste foram analisados com ANOVA um fator. Não encontrou-se diferença significativa (p> 0.005) nos testes de compressão e grau de conversão; já para o teste de estresse de contração,
houve diminuição estatisticamente significativa de até 69% e no teste de resistência à flexão . No quarto capítulo foi feita a incorporação de um polipropileno (PP) e o polietileno de ultra-alto peso molecular (UTEC) a uma resina experimental com os mesmos materiais manipulados no capítulo dois, em
duas concentrações (1,5% e 3%), e realizados os testes de compressão, flexão, grau de conversão e estresse de contração. Os dados de cada teste foram analisados com ANOVA um fator. Não houve diferença significativa (p> 0.005) nos testes de compressão, flexão e grau de conversão; já para o teste de
estresse de contração houve diminuição estatisticamente significativa de até 40%. Conclusão: OPLA+óleo de rícino e o polietileno de ultra alto peso molecular em 1,5%, diminuíram o estresse de contração e propriedades como resistência à flexão, compressão e grau de conversão não foram influenciadas.
|
38 |
Flexural strength comparison of monolayer resin composite to bilayer resin/liner compositeAzzam, Mai Ahmed. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Feb. 5, 2010) Advisor(s): Jeffrey A. Platt, Chair of the Research Committee, Joseph Legan, Carl J. Andres, David Brown, Burak Taskonak . Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 45-52).
|
39 |
Buccal plate changes following rapid versus slow palatal expansion : a cone beam comuted tomography study /Olsen, Justin Todd. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 76-79.
|
40 |
In vitro compressive fracture resistance of the human maxillary first premolar with different mod cavity design and restorative materialsWu, Wen-Chou. January 2007 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2007. / Title from first page of PDF file (viewed Feb. 6, 2008). Includes bibliographical references (p. 36-42).
|
Page generated in 0.0817 seconds