Spelling suggestions: "subject:"alimentaria"" "subject:"complementaria""
281 |
Influência do processamento de próteses totais maxilares com diferentes espessuras da base: análise gráfica da movimentação dos dentes artificiaisMazaro, José Vitor Quinelli [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-15Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1
mazaro_jvq_me_araca.pdf: 2035782 bytes, checksum: e67d1a0017e9c678266d158062acc962 (MD5) / Universidade Estadual Paulista (UNESP) / A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... . / The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below).
|
282 |
Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitosSantos, Ciandrus Moraes de Freitas [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2005Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1
santos_cmf_me_araca.pdf: 1084188 bytes, checksum: 0a96538ac84e5167cd37297d47e91a27 (MD5) / Universidade Estadual Paulista (UNESP) / A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions.
|
283 |
Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitosVerri, Fellippo Ramos [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2003Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1
verri_fr_me_araca.pdf: 6651997 bytes, checksum: 6bb3237d2e73d295c300ea6f6f9c9014 (MD5) / A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants.
|
284 |
Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidadeFerraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1
ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)
|
285 |
Aplicação de princípios de engenharia tecidual no estudo da diferenciação de células-tronco pulparesCasagrande, Luciano January 2008 (has links)
O presente estudo utilizou o modelo fatia-dental/matriz-polimérica para avaliar a influência do tratamento dentinário e das BMPs dentinárias na diferenciação das células-tronco da polpa de dentes decíduos (SHED). Secções transversais (1mm) foram preparadas a partir de terceiros molares humanos extraídos. Matrizes poliméricas a base de ácido poli-L-lático (PLLA) foram criadas no interior da cavidade pulpar das secções dentinárias, tratadas com solução de EDTA a 10%; NaOCl a 5.25%; ou permanecendo sem tratamento. Matrizes poliméricas confeccionadas sem as fatias dentais foram utilizadas como controle. As células (5x104) foram semeadas nas matrizes e, após 7, 14, 21 e 28 dias de cultura in vitro, a expressão de marcadores de diferenciação odontoblástica (DSPP, DMP1 e MEPE) e a proliferação celular (WST-1) foram avaliadas. Células (5x105) semeadas nas matrizes foram transplantadas em camundongos imunodeficientes e cultivadas in vivo por um período de 14 e 28 dias. Para avaliar a atividade das BMPs dentinárias, 5x104 células foram semeadas em matrizes poliméricas com fatia dental e cultivadas na presença de anticorpos anti-BMP- 2, -4, ou -7 (2 μg/ml) durante 14 dias. Adicionalmente, 5x105 células foram tratadas com rhBMP-2, -4, ou -7 (100ng/mL) por 24hs. As células cultivadas in vitro e in vivo alteraram sua expressão genética durante o curso do tempo. DSPP, DMP-1 e MEPE foram expressos por células cultivadas in vitro após 14 dias (tratamento com EDTA e dentina sem tratamento) e in vivo após 28 dias (EDTA), não sendo detectados nos grupos NaOCl e nas células cultivadas nas matrizes sem fatia dental. A proliferação foi reduzida com a diferenciação celular (p<0.05). A utilização de BMP-2/4Ab no meio de cultura exerceu um efeito inibitório na expressão dos marcadores de diferenciação celular, não ocorrendo quando do cultivo das SHED na presença de BMP-7Ab. DSPP, DMP-1 e MEPE foram expressos por células tratadas com rhBMP-2, e DSPP e DMP-1 por células tratadas com rhBMP-4 e -7. Células sem tratamento não expressaram os marcadores. O modelo fatia-dental/matriz-polimérica demonstrou ser adequado para o estudo da diferenciação de células-tronco pulpares, sugerindo que a dentina possa fornecer um microambiente favorável para a diferenciação de celular. As proteínas ósseas morfogenéticas dentinárias BMP-2 e BMP-4 parecem exercer um papel relevante nesse processo. / The effect of dentin pre-treatments and dentin-derived BMPs on SHED differentiation was tested using the Tooth-Slice Scaffold model (TSS). Dentin slices (1mm thickness) were prepared from extracted human third molars. Biodegradable PLLA scaffolds were prepared inside the pulp chamber of the tooth-slices, treated alternatively with a 5.25% NaOCl or 10% EDTA solution, or remaining untreated (WO-T). PLLA sponge scaffolds with no tooth-slice (PSS) were used as control. SHED (5x104) were seeded in TSS and PSS and after 7, 14, 21 and 28 days in culture, RT-PCR (DSPP, DMP1 and MEPE) and WST-1 proliferation assay were performed. Additionally, cells (5x105) were seeded in TSS and PSS and transplanted into SCID mice (14 and 28 days). To verify the dentinderived BMPs bioactivity, SHED (5x104) were cultured in TSS in the presence of antihuman BMP-2, -4, and -7 antibodies for 14 days. Besides, cells in culture were treated with rhBMP-2; -4; or -7 for 24 hours. After in vitro and in vivo time course, SHED altered their genetic expression. The cells cultured in vitro in the TSS (EDTA or WO-T) expressed the differentiation markers after 14 days and maintained expression thereafter. Cell proliferation rate was reduced following the differentiation (p<0.05). Cells transplanted in vivo expressed DSPP, DMP-1 and MEPE after 28 days (EDTA). No transcripts were found in tooth-slices treated with NaOCl or in PSS groups. BMP-2/4Ab prevented the differentiation process and no inhibitory effect was detected for BMP-7Ab. After 24 hours, expression of DSPP, DMP-1 and MEPE was found for rhBMP-2, and DSPP and DMP-1 for rhBMP-4 and rhBMP-7 treated SHED, but not for untreated cells. The tooth slice scaffold model suggests that dentin can provide the environment for SHED differentiation and dentin-derived morphogenic signals BMP-2 and BMP-4 play an important role in this process.
|
286 |
Avaliação do potencial imunomodulador de células-tronco mesenquimais isoladas a partir de polpa dental, tecido adiposo e medula ósseaRodrigues, Felipe Valle Fortes January 2015 (has links)
Introdução: Células tronco mesenquimais (CTM) são uma população residente nos tecidos adultos de origem mesodérmica, com funções regenerativas de manutenção da integridade tecidual, com destaque no desempenho imunomodulador. Esse aspecto levou as CTM a tornarem-se ferramentas terapêuticas valiosas da pesquisa à assistência ao paciente em doenças autoimunes e de cunho inflamatório. Além disso, CTM podem ser isoladas de materiais tidos como descarte de procedimentos, como dentes decíduos, filtros de transplante de medula óssea e gordura. Nesse panorama, torna-se necessário estabelecer o efeito que a origem tecidual tem na eficiência imunoreguladora e na possível aplicabilidade clínica destas células. Objetivo: Comparar o potencial imunomodulador de células mesenquimais isoladas a partir de filtros descartados após a infusão de medula óssea, de lipoaspirado e de polpa de dentes decíduos. Métodos: Foi realizada a comparação da capacidade proliferativa de CTMs, cultivadas na presença de lisado plaquetário, das diversas fontes através do cálculo de population doubling das CTM em co-cultura com linfócitos T isolados em coluna magnética e com células mononucleares de sangue periférico, estimuladas com fitohemaglutinina; e determinado por citometria de fluxo o efeito das CTM das diversas fontes sobre as subpopulações linfocitárias. Resultados: CTM das três fontes foram capazes de inibir a proliferação de linfócitos e CTM de tecido adiposo foram mais eficientes em induzir o fenótipo de células T reguladoras e na diminuição de células T citotóxicas. Conclusão: comparadas à CTM isoladas de medula óssea e de polpa dentária, as CTM originadas de tecido adiposo exibem efeito imunomodulador mais acentuado. / Background: Mesenchymla stromal cells (MSC) reside in most adult tissue of mesenchymal origen, with a broad functions envolving cell repopulation and maintenence of tissue homeostasis, trough immunemmodulatory action. MSC are valuable terapêutic instruments applied from research to autoimune and inflamatory diseases. MSC can be isolated from diverse discarted biological matherials, like lipoaspirate, exfoliated deciduous teeeth and boné marrow ransplant filters. There so it´s necessary to stablish how source can impact MSC efficiency and possible clinical aplications. Objective: Compare immunomodulatory potential of adipose MSC and dental pulp MSC to boné marrow MSC. Methods: MSC from three selected sources were cocultured with phytohemaglutinin stimulated and magnetically isolated T cells and peripheral blood mononuclear cells; immunephenotype of cocultivated lymphocytes were also conducted. Results: MSC from all analyzed sources were capable to inhibit lymphocyte proliferation. Adipose MSC were capable to induce Treg phenotype and decrease T CD8+ limphocytes. Conclusion: Cell culture and therapy with MSC present many paradigms and we address to some of those to elucidate the possible most efficient source.
|
287 |
Avaliação da ponta de diamante CVC (Chemical Vapor Deposition) associada ao aparelho de ultra-somLima, Luciana Monti [UNESP] 25 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-04-25Bitstream added on 2014-06-13T20:44:35Z : No. of bitstreams: 1
lima_lm_dr_arafo.pdf: 12608826 bytes, checksum: 6a6a6f942941a1dbbddbe92d7ac3a87e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre os instrumentos de corte alternativos aos rotatórios de baixa e alta rotação que foram introduzidos na Odontologia, o uso do ultra-som associado à ponta de diamante CVD (Chemical Vapor Deposition) vem apresentando desempenho positivo, especialmente em relação à preservação da estrutura dentária e à satisfação dos pacientes. Diante de uma tecnologia ainda pouco explorada, o objetivo deste estudo foi avaliar a efetividade da ponta de diamante CVD em ultra-som, buscando evidências científicas que suportem a sua utilização no tratamento odontológico, por meio de 3 artigos seqüenciais. Estes artigos abordaram as implicações desta nova técnica de preparo cavitário na efetividade de corte de esmalte e dentina, na resistência de união por microtração e microinfiltração de restaurações de resina composta e na resposta do complexo dentino-pulpar de dentes humanos, tendo como grupo controle a ponta diamantada convencional associada à turbina de alta rotação. Os resultados evidenciaram que os preparos cavitários em esmalte e dentina confeccionados com ponta de diamante CVD em ultra-som foram mais conservadores do que os preparos com a ponta diamantada em alta rotação. As restaurações em resina composta confeccionadas após o preparo cavitário com a ponta de diamante CVD em ultrasom apresentaram valores de resistência de união significantemente maiores, no entanto, a microinfiltração nas margens em esmalte e dentina não foram diferentes entre os instrumentos de corte. Além disso, não foram observadas características de inflamação nas respostas pulpares após a utilização de ambos os instrumentos de corte, apenas uma discreta a moderada desorganização celular. / The CVD (Chemical Vapor Deposition) diamond tip coupled in ultrasound device by means of a specific connector has been an alternative to conventional diamond bur in high-speed. Besides the few scientific evidences, this new technology has been used in dental offices with good results, especially regarding the preservation of dental tissues and patient’s satisfaction. The aim of this study was to evaluate the effectiveness of the CVD diamond tip in ultrasound on dental treatment, through 3 sequential articles. These articles evaluated the implications of this new cavity preparation technique in enamel and dentin cutting effectiveness, in microtensile bond strength and microleakage of composite resin restorations, and in dentin-pulp complex response of human teeth, having the high-speed conventional diamond bur as control group. The results showed that the cavity preparations made by CVD diamond tip in enamel and dentin were more conservative than those prepared by conventional diamond bur. The resin composite restorations placed after cavity preparation with CVD diamond tip in ultrasound showed significantly higher bond strength values, however, the microleakage in enamel and dentin margins were similar for both cutting instruments. Besides, pulp response for both instruments did not show inflammatory characteristics, only a discrete or moderate cellular disorganization.
|
288 |
Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitosVerri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1
verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
|
289 |
Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitosLucas, Liliana Vicente Melo de [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-12-18Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1
lucas_lvm_dr_araca.pdf: 2722998 bytes, checksum: 4598b84f7bad6e641b9c428ccef728d3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide.... / The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below)
|
290 |
Aplicação de princípios de engenharia tecidual no estudo da diferenciação de células-tronco pulparesCasagrande, Luciano January 2008 (has links)
O presente estudo utilizou o modelo fatia-dental/matriz-polimérica para avaliar a influência do tratamento dentinário e das BMPs dentinárias na diferenciação das células-tronco da polpa de dentes decíduos (SHED). Secções transversais (1mm) foram preparadas a partir de terceiros molares humanos extraídos. Matrizes poliméricas a base de ácido poli-L-lático (PLLA) foram criadas no interior da cavidade pulpar das secções dentinárias, tratadas com solução de EDTA a 10%; NaOCl a 5.25%; ou permanecendo sem tratamento. Matrizes poliméricas confeccionadas sem as fatias dentais foram utilizadas como controle. As células (5x104) foram semeadas nas matrizes e, após 7, 14, 21 e 28 dias de cultura in vitro, a expressão de marcadores de diferenciação odontoblástica (DSPP, DMP1 e MEPE) e a proliferação celular (WST-1) foram avaliadas. Células (5x105) semeadas nas matrizes foram transplantadas em camundongos imunodeficientes e cultivadas in vivo por um período de 14 e 28 dias. Para avaliar a atividade das BMPs dentinárias, 5x104 células foram semeadas em matrizes poliméricas com fatia dental e cultivadas na presença de anticorpos anti-BMP- 2, -4, ou -7 (2 μg/ml) durante 14 dias. Adicionalmente, 5x105 células foram tratadas com rhBMP-2, -4, ou -7 (100ng/mL) por 24hs. As células cultivadas in vitro e in vivo alteraram sua expressão genética durante o curso do tempo. DSPP, DMP-1 e MEPE foram expressos por células cultivadas in vitro após 14 dias (tratamento com EDTA e dentina sem tratamento) e in vivo após 28 dias (EDTA), não sendo detectados nos grupos NaOCl e nas células cultivadas nas matrizes sem fatia dental. A proliferação foi reduzida com a diferenciação celular (p<0.05). A utilização de BMP-2/4Ab no meio de cultura exerceu um efeito inibitório na expressão dos marcadores de diferenciação celular, não ocorrendo quando do cultivo das SHED na presença de BMP-7Ab. DSPP, DMP-1 e MEPE foram expressos por células tratadas com rhBMP-2, e DSPP e DMP-1 por células tratadas com rhBMP-4 e -7. Células sem tratamento não expressaram os marcadores. O modelo fatia-dental/matriz-polimérica demonstrou ser adequado para o estudo da diferenciação de células-tronco pulpares, sugerindo que a dentina possa fornecer um microambiente favorável para a diferenciação de celular. As proteínas ósseas morfogenéticas dentinárias BMP-2 e BMP-4 parecem exercer um papel relevante nesse processo. / The effect of dentin pre-treatments and dentin-derived BMPs on SHED differentiation was tested using the Tooth-Slice Scaffold model (TSS). Dentin slices (1mm thickness) were prepared from extracted human third molars. Biodegradable PLLA scaffolds were prepared inside the pulp chamber of the tooth-slices, treated alternatively with a 5.25% NaOCl or 10% EDTA solution, or remaining untreated (WO-T). PLLA sponge scaffolds with no tooth-slice (PSS) were used as control. SHED (5x104) were seeded in TSS and PSS and after 7, 14, 21 and 28 days in culture, RT-PCR (DSPP, DMP1 and MEPE) and WST-1 proliferation assay were performed. Additionally, cells (5x105) were seeded in TSS and PSS and transplanted into SCID mice (14 and 28 days). To verify the dentinderived BMPs bioactivity, SHED (5x104) were cultured in TSS in the presence of antihuman BMP-2, -4, and -7 antibodies for 14 days. Besides, cells in culture were treated with rhBMP-2; -4; or -7 for 24 hours. After in vitro and in vivo time course, SHED altered their genetic expression. The cells cultured in vitro in the TSS (EDTA or WO-T) expressed the differentiation markers after 14 days and maintained expression thereafter. Cell proliferation rate was reduced following the differentiation (p<0.05). Cells transplanted in vivo expressed DSPP, DMP-1 and MEPE after 28 days (EDTA). No transcripts were found in tooth-slices treated with NaOCl or in PSS groups. BMP-2/4Ab prevented the differentiation process and no inhibitory effect was detected for BMP-7Ab. After 24 hours, expression of DSPP, DMP-1 and MEPE was found for rhBMP-2, and DSPP and DMP-1 for rhBMP-4 and rhBMP-7 treated SHED, but not for untreated cells. The tooth slice scaffold model suggests that dentin can provide the environment for SHED differentiation and dentin-derived morphogenic signals BMP-2 and BMP-4 play an important role in this process.
|
Page generated in 0.0767 seconds